HomeMy WebLinkAboutNOAMlAMI
s
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA) F
The QUIIQ2ETE® Companies, Inc.
500 Marathon Parkway
Lawrenceville, GA 30046
APR 2 3 2019
ST. Lucie County, Permitting
MIANH-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
1 T (786)315-2590 F (786) 315-2599
www.miamidade.gov/ccononiv
SCANNED
BY
St. Lucie County
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: QUIKRETE® Roof Tile Mortar FL-15
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety. REVIEWED FOR
INSPECTION: A copy of this entire NOA shall be provided to the usaMsommaANGFors and
shall be available for inspection at the job site at the request of the Buildingo i1 UCiE®V IN
TY
This NOA revises and renews NOA 14-0211.12 and consists of pages 1 through 6. ROCC
The submitted documentation was reviewed by Alex Tigera.
FILE COFI
-0625.04
MIAMI•DADE COUNTY N ANoa e: 11106119
.., � � Expiration Date: 11/06/19
Approval Date: 10/08/15
Page 1 of 6
ROOFING COMPONENT APPROVAL:
Category
Sub Category
Materials:
SCOPE:
Roofing
Roofing Tile Adhesives
Cement
This approves QUIKRETE® Roof Tile Mortar FL-15 as manufactured by The QUIKRETE® Companies, Inc. as
described in this Notice of Acceptance.
PRODUCTS MANUFACTURED BY OR LABELED BY APPLICANT:
Test
Product Dimensions Specifications Product Description
QUIKRETE® Roof Tile 80 lb. bags TAS 123 Premixed pre -bagged gray roof tile mortar for
Mortar FL-15 use with approved roof tiles in accordance with
RAS 120
MANUFACTURING LOCATIONS:
1. Miami, FL
2. Lakeland, FL
3. Jacksonville, FL
4. Ft. Myers, FL.
EVIDENCE SUBMITTED:
Test A2encv Test Identifier Test Name/Report Date
Center for Applied Engineering Metro Dade Protocol
TAS 101
Florida Testing and Engineering, Inc.
ASTM C 91 Type M
PRI Construction Materials Technologies
TAS 123
QKT-003-02-01
10/15/09
TAS 123
QKT-004-02-02INT
10/23/14
TAS 123
QKT-007-02-01
06/26/15
Construction Technology.Laboratories, Inc.
ASTM C 270
385045
06/14/10
NOA No.: 15-0625.04
MIAMFDADECOUNW Expiration Date: 11/06/19
Approval Date: 10/08/15
Page 2 of 6
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. Field uplift testing shall be performed, in accordance with the test procedures set forth in Roofing Application
Standard RAS 106. Testing shall be performed not prior to 30 days after installation.
3. Quikrete® Roof Tile Mortar FL — 15 shall be placed in a 5" x 12" pad at time of application. The mortar pad
placement shall be in accordance with the 'Placement Details' provided herein. Each generic tile profile requires a
specific placement, (see Placement Detail listed herein).
4. Quikrete®Roof Tile Mortar FL - 15 shall be applied in accordance with The QUIKRETE® Companies, Inc.'s
specifications.
5. Tile must be applied within 5 minutes of the application of Quikrete® Roof Tile Mortar. FL —15.
6. Refer to the tile manufacturer's Miami -Dade County Product Control Notice of Acceptance for system approvals.
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
5. All bags shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city and state of manufacturing facility, and following statement: "Miami -Dade County Product Control
Approved" or the Miami -Dade County Product Control Seal as shown below.
INSTALLATION:
1. Quikrete®Roof Tile Mortar FL - 15 and its components shall be installed in strict compliance with Roofing
Application Standard RAS 120.
2. Mortar placement shall be in accordance with the placement details specified below.
PLACEMENT DETAILS
TmE PROFILE:
DETAn, NO.
Medium Profile
A
Flat Profile
B
High Profile
C
BUILDING PERMIT REQUIREMENTS:
1. As required by the Building Official or applicable building code in order to properly evaluate the installation of
this system.
NOA No.: 15-0625.04
Expiration Date: 11/06/19
Approval Date: 10/08/15
Page 3 of 6
FASCIA
PLACEMENT DETAIL "All
NAIL HERE THROUGH PLASTIC
ROOF CEMENT (WHEN A➢DITIONAL
.: '.10 MASON TROWEL / NAILING IS REQUIRED BY CODE)
MORTAR PLACEMENT RC7LL TILE
PLACEMENT DETAIL "B"
NoTo MORTAR CONTACT lE x.➢E WITH ]
Tn[s.
No NET
REACH ONTO
TIE HEAD orOR UNTO UN➢ERLOCN
Or AD -TILE IIM CENT OTIIL
HE
1. Tor THE TILE
N y➢ RLOCK SI➢E
UNDERSIDE or
ETi
ID. H
THE L[ ONSET
SERED7
NEnRn
;v'
CEMENT
THROUGH[
WHEN ADDITIONAL
MAIL.NO IS
¢EOVIaE➢ AT Cvvll
I-
ROINERA RELT
FI.D
DIALSuArAC
En E ➢RI
_ ^�
TRICNeUTT
TILES'
_HALF
-
FCUT
TYLE
SCHEMATIC
H W
R
A M
NT — FLAT TILE
NOA No.: 15-0625.04
Expiration Date: 11/06/19
Approval Date: 10/08/15
Page 4 of 6
PLACEMENT DETAIL "C"
FASTENER AND SEALANT
ON CAP SHEET
(WHEN REQUIRED)
9 OVERLAP
MORTAR PADDY --�.�! J
r
ROLLED GABLE
(SPANISH "S" CUTS)
WEEPHOLE EAVE CLOSURE POINT MORTAR
TO FINISH
NOA No.: 15-0625.04
Expiration Date: 11/06/19
Approval Date: 10/08/15
Page 5 of 6
PLACEMENT DETAIL "C' (CONTINUED)
COVER NAILER BOARD
—� (WHEN REQUIRED)
PAN
MORTAR
PLACEMANT
FASTENER AND SEALANT
OR CAP SHEET
(WHEN REQUIRED)
FASTENER AND SCALANNT
OR CAP SHEET
(WHEN REQUIRED)
WMORTAR BED
WEEP HOLE
AND POINT TO FINISH
END OF THIS ACCEPTANCE
NOA No.: 15-0625.04
MIAMI-DADECOUNTY Expiration Date:11/06/19
Approval Date: 10/08/15
Page 6 of 6
n
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA) �-
ICP Adhesives and Sealants, Inc.
12505 NW 44"Street
Coral Springs, FL. 33065
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786)315-2590 F (786) 315-2599
71 www.miamidade.eov/econonry
SCANNED
BY
St. Lucie County
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
APR 2 3 2019
ST. Lucie County, Permitting
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polyset® AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
REVIEWED F
INSPECTION: A copy of this entire NOA shall be provided to the user f� y��p r Its d1 tors and
shall be available for inspection at the job site at the request of the Building O tc �+CJMPLIAN(r ice•
This NOA renews NOA 16-0315.01 and consists of pages I through 11. STe LUCIE C®UNTY
The submitted documentation was reviewed by Alex Tigera. BOCC
/^ NOA No.: 17-0322.03
FILE ADO Expiration Date: 05/10/22
roval Date: 04/27/17
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP
Adhesives Polyset® AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
ICP Adhesives N/A
Polyset®AH-160
ICP Adhesives Foam N/A
Dispenser RTF1000
ICP Adhesives ProPack® N/A
30 & 100
TAS 101 - Two component polyurethane foam adhesive
PRODUCTS MANUFACTURED BY OTHERS:
Dispensing Equipment
Dispensing Equipment
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
Tomball, TX.
PHYSICAL PROPERTIES:
Property
Test
Results
Density
ASTM D 1622
1.6 lbS./fr.3
Compressive Strength
ASTM D 1621
18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength
ASTM D 1623
28 PSI Parallel to rise
Water Absorption
ASTM D 2127
0.08 Lbs./Ft2
Moisture Vapor Transmission
ASTM E 96
3.1 Perm / Inch
Dimensional Stability
ASTM D 2126
+0.07% Volume Change @ -400 F., 2 weeks
+6.0% Volume Change @1580F., 100% Humidity, 2
weeks
Closed Cell Content
ASTM D 2856
86%
Note: The physical properties listed
above are presented as typical average values as determined by
accepted ASTM test methods
and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
MAMMADECOUNW
il•I7Ti4Id�7
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2 of 11
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Center for Applied Engineering
#94-060
TAS 101
04/08/94
257818-IPA
TAS 101
12/16/96
25-7438-3
SSTD 11-93
10/25/95
25-7438-4
25-7438-7
SSTD 11-93
11/02/95
25-7492
SSTD 11-93
12/12/95
Miles Laboratories
NB-589-631
ASTM D 1623
02/01/94
Polymers Division
Ramtech Laboratories, Inc.
9637-92
ASTM E 108
04/30/93
Southwest Research Institute
01-6743-011
ASTM E 108
11/16/94
01-6739-062b[l]
ASTM E 84
01/16/95
Trinity Engineering
7050.02.96-1
TAS 114
03/14/96
P36700.04.12
ASTM D 1623
04/18/12
P39740.02.12
TAS 101
02/21/12
TAS 123
Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160.
2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by ICP Adhesives and
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between
1.0-1.15 (A): 1.0 (B).
6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP
Adhesives ProPack® 30 & 100 dispensing equipment only.
7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset® AH-160 has been dispensed.
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details' herein. Each generic tile profile requires the specific placement noted herein.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact
Minimum Paddy Gram
Area
Weight
Eave Course - Flat, Low, High
All Eave Course
17-23 sq. inches
45-65
Profiles
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
30
Low Profile
#2
12-14 sq. inches
30
High Profile
#2
17-19 sq. inches
30
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (I each longitudinal
17 grams per bead
edge) 20-25 sq. inches each
bead
Two Piece Bartel (Pan Tile)
Two Piece
65-70 sq. inches
34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
P'7A1716dGE COUNIT
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
ADHESIVE PLACEMENT DETAIL i I
Usdy4ymene
l
Naa iheeug4l piafeis cery.wnR,
(aY,an RWi tf �.. WdBr lH�nwe{,Txlfl
}-,, r
{Din•R
a
aPUonai .�'
€araceune "
Fa:aa
Weephde
10 In, -t in. � ndEattdasure
Pedv
Plat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2)-23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cmZ) — 23 (148.4 cm') square inch adhesive
contact with the underside of the tile.
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 nun) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm) — 23 (148.4 cmZ) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6 of 11
T1
ADHESIVE PLACEMENT DETAIL # 2
F„'"
Flat/Low Profile Tile
1. Starting at the cave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm2)
— 23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 10"
(64.5 cm2) - 12 (77.4 cm2) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
Starting at the cave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm2) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
M AMMADE COUNTY
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 17"
(109.7 cm2) - 19 (122.6 cmZ) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
ADHESIVE PLACEMENT DETAIL # 3
tendwiffO
t a:4iM
o fi,
lain. "-•;�;�,
Flattkow PraflleTlle
paddyendffib7e
Eave aamre
Medium Pro0leTlle
On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x V (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 inZ (109.7-148.4 cmZ) of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4
mm) foam paddy onto the underlayment just below
the second course line positioned foam paddy
under the strengthening rib for flat tile, or under the
pan portion of the tile, closest to the underlock for
the second course tile to be installed. Insure
approximately 8-9 in' (51.6-58.1 cin) of adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
affitens
lib
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
High ProflleTOe
Him)
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x%"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cmZ) - 11 (71 cmZ) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm') - 9 (58.1 cmZ) square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
Ule.
Ea re dosure
lmotarsimwnj
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
Remore top portion of the eaw course corer tile. Abut to secand worse of
pan tiles. Ensure save end of pen and Caner taes are f lush ateave fine.
Two Piece Barrel -High Profile Tile
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cm2) — 70 (451.6 cm2)
square inch adhesive contact with the underside
of the pan tile.
3. Turn covers upside down exposing the underside
of the tile. Apply a minimum 1" (25.4 mm) x 10"
(254 mm) bead of adhesive directly on the inner
edge of each side of the cover tile. Leave
approximately 3/4" (19 mm) to 1" (25.4 mm)
from the outside edge of the tile, inward, free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20 (129 cm2) - 25 (161.3 cm2) square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) milers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11
MIAMIZADE
Em
DEPARTMENT OF REGULATORY AND ECONOM
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NO:
Boral Roofing, LLC
7575 Irvine Center Drive Suite 100
Irvine, CA 92618
SCANNED
BY
St. Lucie County MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Sheet, Room208
(RER) Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
APR 2 3 2019
ST. Lucie County, Permitting
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in
Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Bermuda Concrete Flat Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approve(P", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA. / cj p - O5--Z-y
ADVERTISEMENT: The NOA number preceded by the words Mia>@ ) #QoEDRd followed by the
expiration date may be displayed in advertising literature. If any pdQQ®S QoMftl4AIfte shall be done
in its entirety. ST. LUCIE COUNTY
INSPECTION: A copy of this entire NOA shall be provided to the user by the or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
60�-
This NOA revises NOA No. 16-0112.07 and consists of pages 1 through 6.
The submitted documentation was reviewed by Freddy Semino 510
APPROVED J
FILE COPY
NOA No.19-0220.06
Expiration Date: 06/07/21
Approval Date: 04/11/19
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Bermuda Flat Concrete Roof Tile, as manufactured Boral Roofing, LLC in
Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building
Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by
applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127
using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant Dimensions
Bermuda Flat Concrete Tile Length = 16"
Width= 10"
Trim Pieces 1= varies
w = varies
varying thickness
2.1 MANUFACTURING LOCATION
1. Okeechobee, FL
2.2 EVIDENCE SUBMITTED
Test Asencv
Redland Technologies
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
The Center for Applied Engineering,
Inc.
Test
Specifications
Product
Description
TAS 112 Flat profile, interlocking, high pressure extruded
Type 3a concrete roof file equipped with two nail holes.
Class III For mechanical, mortar or adhesive set
applications.
TAS 112 Accessory trim, concrete roof pieces for use at
hips, rakes, ridges and valley terminations.
Manufactured for each tile profile.
Test Identifier
Test Name/Report
Date
7161-03
Static Uplift Testing
Dec. 1991
Appendix III
PA 102 & PA 102(A)
94-084
Static Uplift Testing
May 1994
PA 101 (Mortar Set)
94-060A
Static Uplift Testing
March, 1994
PA 101 (Adhesive Set)
25-7094-2
Static Uplift Testing PA 102
Oct. 1994
(4" Headlap, Nails, Direct Deck, New
Construction)
25-7094-8
Static Uplift Testing PA 102
Oct. 1994
(4" Headlap, Nails, Battens)
25-7094-5
Static Uplift Testing PA 102
Oct. 1994
(4" Headlap, Nails, Direct Deck,
Recover/Reroof)
25-7183-6
Static Uplift Testing PA 102
Feb. 1995
(2 Quik-Drive Screws, Direct Deck)
NOA No.19-0220.06
Expiration Date: 06/07/21
Approval Date: 04/11/19
Page 2 of 6
2.2 EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
The Center for Applied Engineering,
25-7183-5
Static Uplift Testing
Feb. 1995
Inc.
PA 102
(2 Quik-Drive Screws, Battens)
The Center for Applied Engineering,
25-7214-1
Static Uplift Testing
March, 1995
Inc.
PA 102
(1 Quik-Drive Screw, Direct Deck)
The Center for Applied Engineering,
25-7214-5
Static Uplift Testing
March, 1995
Inc.
PA 102
(1 Quik-Drive Screw, Battens)
Redland Technologies
7161-03
Wind Tunnel Testing
Dec. 1991
Appendix Il
PA 108 (Nail -On)
Redland Technologies
Letter Dated Aug. 1,
Wind Tunnel Testing
Aug. 1994
1994
PA 108 (Nail -On)
Redland Technologies
P0631-01
Wind Tunnel Testing
July 1994
PA 108 (Mortar Set)
Redland Technologies
P0402
Withdrawal Resistance Testing of screw
Sept. 1993
vs. smooth shank nails
The Center for Applied Engineering,
Project No. 307025
Wind Driven Rain
Oct. 1994
Inc.
Test #MDC-77
PA 100
Atlanta Testing & Engineering, Inc.
R1.894
Physical Properties
Aug. 1994
R2.894
PA 112
R3.894
Professional Service Industries, Inc.
395-40011-1
Physical Properties
Feb 2004
PA 112
Celotex Corporation Testing Service
520109-1
Static Uplift Testing
Dec. 1998
520111-4
PA 101
Celotex Corporation Testing Service
520191-1
Static Uplift Testing
March 1999
PA 101
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplier
March 2004
Walker Engineering, Inc.
Evaluation Calculations
25-7094
Feb 1996
Walker Engineering, Inc.
Evaluation Calculations
25-7496
April 1996
Walker Engineering, Inc.
Evaluation Calculations
25-7584
December
25-7804b-8
1996
25-7804-4 & 5
25-7848-6
Walker Engineering,'Inc.
Evaluation Calculations
25-7183
March 1995
Walker Engineering, Inc.
Evaluation Calculations
Restoring Moment, Mg
March 2004
Walker Engineering, Inc.
Calculations
Two Patty Adhesive Set System
April 1999
Nutting Engineers
13343.1
TAS 112
05/06/08
American Test Lab of South Florida
RT1210.02-15
TAS 112
12/17/15
RT0807.04-18
TAS 112
08/27/18
NOA No.19-0220.06
WMIAWDADECOUNTY= Expiration Date: 06/07/21
Approval Date: 04/11/19
Page 3 of 6
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may be
required, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control
Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
4. INSTALLATION
4.1 Boral Bermuda `Flat' Concrete Roof Tile and its components shall be installed in strict compliance with
Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations.
Table 1: Average Weight (VI) and Dimensions (I x w )
Tile Profile
Weight-W (lb f)
Length -I (ft.)
Width-w (ft.)
Bermuda Flat Tile
9.7 ,
1.33
.833
Table 2: Aerodynamic Multipliers - 2 (W)
Tile
Profile
X (ft3)
Batten Application
2. (ft3)
Direct Deck Application
Bermuda Flat Tile
0.189
0.205
Table 3: Restoring Moments due to Gravity - M9 (ft.-Ibf)
Tile
Profile
3":12"
4":12"
5":12"
6":12"
Greater than
7":12"
Bermuda Flat
Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
I Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
6.53
6.97
6.43
6.86
6.29
6.71
6.14
6.54
5.97
6.35
NOA No.19-0220.06
Expiration Date: 06/07/21
Approval Date: 04/11/19
Page 4 of 6
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15/32" plywood)
Direct Deck
(min.19/32" plywood)
Battens
Bermuda
2-10d Ring Shank Nails
30.9
38.1
17.2
Flat Tile
1-10d Smooth or Screw
Shank Nail
7.3
9.8
4.9
2-10d Smooth or Screw
Shank Nails
14.0
18.8
7.4
1 #8 Screw
30.8
30.8
18.2
2 #8 Screw
51.7
51.7
24.4
1-10d Smooth or Screw
Shank Nail Field Clip)
24.3
24.3
24.2
1-10d Smooth or Screw
Shank Nail Eave Clip)
19.0
19.0
22.1
2-10d Smooth or Screw
Shank Nails Field Clip)
35.5
35.5
34.8
2-10d Smooth or Screw
Shank Nails Eave Clip)
31.9
31.9
32.2
2-10d Ring Shank Nails' 1 50.3 65.5 48.3
1 Installation with a 4" the headlap and fasteners are located a min. of 2%" from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mr (ft: Ibf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment Resistance
Bermuda Flat Tile
Adhesive
31.33
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TileBond Average weight per patty 13,9 grams.
3M' 2-Component Foam Roof Tile Adhesive AH-160. Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mr (ft.-lbf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Bermuda Flat
3W 2-Component Foam Roof Tile Adhesive AH-160
118.94
Tile
3M'" 2-Component Foam Roof Tile Adhesive AH-160
40.45
4 Lar a add
lacement of 45 rams of 3M " 2-Component Foam Roof Tile Adhesive AH-160
5 Medium add placement of 24 grams of 31VI' 2-Component Foam Roof Tile Adhesive AH-160
NOA No.19-0220.06
Expiration Date: 06/07/21
Approval Date: 04/11/19
Page 5 of 6
5. LABELING
All tiles shall bear the imprint or identifiable marldng of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
Bermuda Flat Concrete Tile
LABEL (LOCATED ON UNDERSIDE OF TILE) '
BUILDING PERmn REQUIREMENTS:
As required by the Building Official or the applicable Building Code in order to properly evaluate the
installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit.
PROFILE DRAWING
Bermuda "FLAT' CONCRETE ROOF TILE
16'
FIELD TILE
16'
7 TBICK BUTT TILE
END OF THIS ACCEPTANCE
NOA No.19-0220.06
MIAMMADE COUNTY Expiration Date: 06/07/21
FUTO I Approval Date: 04/11/19
Page 6 of 6