Loading...
HomeMy WebLinkAboutNOAMlAMI s DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) F The QUIIQ2ETE® Companies, Inc. 500 Marathon Parkway Lawrenceville, GA 30046 APR 2 3 2019 ST. Lucie County, Permitting MIANH-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 1 T (786)315-2590 F (786) 315-2599 www.miamidade.gov/ccononiv SCANNED BY St. Lucie County SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: QUIKRETE® Roof Tile Mortar FL-15 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. REVIEWED FOR INSPECTION: A copy of this entire NOA shall be provided to the usaMsommaANGFors and shall be available for inspection at the job site at the request of the Buildingo i1 UCiE®V IN TY This NOA revises and renews NOA 14-0211.12 and consists of pages 1 through 6. ROCC The submitted documentation was reviewed by Alex Tigera. FILE COFI -0625.04 MIAMI•DADE COUNTY N ANoa e: 11106119 .., � � Expiration Date: 11/06/19 Approval Date: 10/08/15 Page 1 of 6 ROOFING COMPONENT APPROVAL: Category Sub Category Materials: SCOPE: Roofing Roofing Tile Adhesives Cement This approves QUIKRETE® Roof Tile Mortar FL-15 as manufactured by The QUIKRETE® Companies, Inc. as described in this Notice of Acceptance. PRODUCTS MANUFACTURED BY OR LABELED BY APPLICANT: Test Product Dimensions Specifications Product Description QUIKRETE® Roof Tile 80 lb. bags TAS 123 Premixed pre -bagged gray roof tile mortar for Mortar FL-15 use with approved roof tiles in accordance with RAS 120 MANUFACTURING LOCATIONS: 1. Miami, FL 2. Lakeland, FL 3. Jacksonville, FL 4. Ft. Myers, FL. EVIDENCE SUBMITTED: Test A2encv Test Identifier Test Name/Report Date Center for Applied Engineering Metro Dade Protocol TAS 101 Florida Testing and Engineering, Inc. ASTM C 91 Type M PRI Construction Materials Technologies TAS 123 QKT-003-02-01 10/15/09 TAS 123 QKT-004-02-02INT 10/23/14 TAS 123 QKT-007-02-01 06/26/15 Construction Technology.Laboratories, Inc. ASTM C 270 385045 06/14/10 NOA No.: 15-0625.04 MIAMFDADECOUNW Expiration Date: 11/06/19 Approval Date: 10/08/15 Page 2 of 6 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. Field uplift testing shall be performed, in accordance with the test procedures set forth in Roofing Application Standard RAS 106. Testing shall be performed not prior to 30 days after installation. 3. Quikrete® Roof Tile Mortar FL — 15 shall be placed in a 5" x 12" pad at time of application. The mortar pad placement shall be in accordance with the 'Placement Details' provided herein. Each generic tile profile requires a specific placement, (see Placement Detail listed herein). 4. Quikrete®Roof Tile Mortar FL - 15 shall be applied in accordance with The QUIKRETE® Companies, Inc.'s specifications. 5. Tile must be applied within 5 minutes of the application of Quikrete® Roof Tile Mortar. FL —15. 6. Refer to the tile manufacturer's Miami -Dade County Product Control Notice of Acceptance for system approvals. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 5. All bags shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. INSTALLATION: 1. Quikrete®Roof Tile Mortar FL - 15 and its components shall be installed in strict compliance with Roofing Application Standard RAS 120. 2. Mortar placement shall be in accordance with the placement details specified below. PLACEMENT DETAILS TmE PROFILE: DETAn, NO. Medium Profile A Flat Profile B High Profile C BUILDING PERMIT REQUIREMENTS: 1. As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 15-0625.04 Expiration Date: 11/06/19 Approval Date: 10/08/15 Page 3 of 6 FASCIA PLACEMENT DETAIL "All NAIL HERE THROUGH PLASTIC ROOF CEMENT (WHEN A➢DITIONAL .: '.10 MASON TROWEL / NAILING IS REQUIRED BY CODE) MORTAR PLACEMENT RC7LL TILE PLACEMENT DETAIL "B" NoTo MORTAR CONTACT lE x.➢E WITH ] Tn[s. No NET REACH ONTO TIE HEAD orOR UNTO UN➢ERLOCN Or AD -TILE IIM CENT OTIIL HE 1. Tor THE TILE N y➢ RLOCK SI➢E UNDERSIDE or ETi ID. H THE L[ ONSET SERED7 NEnRn ;v' CEMENT THROUGH[ WHEN ADDITIONAL MAIL.NO IS ¢EOVIaE➢ AT Cvvll I- ROINERA RELT FI.D DIALSuArAC En E ➢RI _ ^� TRICNeUTT TILES' _HALF - FCUT TYLE SCHEMATIC H W R A M NT — FLAT TILE NOA No.: 15-0625.04 Expiration Date: 11/06/19 Approval Date: 10/08/15 Page 4 of 6 PLACEMENT DETAIL "C" FASTENER AND SEALANT ON CAP SHEET (WHEN REQUIRED) 9 OVERLAP MORTAR PADDY --�.�! J r ROLLED GABLE (SPANISH "S" CUTS) WEEPHOLE EAVE CLOSURE POINT MORTAR TO FINISH NOA No.: 15-0625.04 Expiration Date: 11/06/19 Approval Date: 10/08/15 Page 5 of 6 PLACEMENT DETAIL "C' (CONTINUED) COVER NAILER BOARD —� (WHEN REQUIRED) PAN MORTAR PLACEMANT FASTENER AND SEALANT OR CAP SHEET (WHEN REQUIRED) FASTENER AND SCALANNT OR CAP SHEET (WHEN REQUIRED) WMORTAR BED WEEP HOLE AND POINT TO FINISH END OF THIS ACCEPTANCE NOA No.: 15-0625.04 MIAMI-DADECOUNTY Expiration Date:11/06/19 Approval Date: 10/08/15 Page 6 of 6 n DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) �- ICP Adhesives and Sealants, Inc. 12505 NW 44"Street Coral Springs, FL. 33065 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 71 www.miamidade.eov/econonry SCANNED BY St. Lucie County SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). APR 2 3 2019 ST. Lucie County, Permitting This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. REVIEWED F INSPECTION: A copy of this entire NOA shall be provided to the user f� y��p r Its d1 tors and shall be available for inspection at the job site at the request of the Building O tc �+CJMPLIAN(r ice• This NOA renews NOA 16-0315.01 and consists of pages I through 11. STe LUCIE C®UNTY The submitted documentation was reviewed by Alex Tigera. BOCC /^ NOA No.: 17-0322.03 FILE ADO Expiration Date: 05/10/22 roval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications ICP Adhesives N/A Polyset®AH-160 ICP Adhesives Foam N/A Dispenser RTF1000 ICP Adhesives ProPack® N/A 30 & 100 TAS 101 - Two component polyurethane foam adhesive PRODUCTS MANUFACTURED BY OTHERS: Dispensing Equipment Dispensing Equipment Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset® AH-160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.6 lbS./fr.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft2 Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -400 F., 2 weeks +6.0% Volume Change @1580F., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 MAMMADECOUNW il•I7Ti4Id�7 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: 1. ICP Adhesives Polyset® AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP Adhesives ProPack® 30 & 100 dispensing equipment only. 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset® AH-160 has been dispensed. 9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (I each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Bartel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. P'7A1716dGE COUNIT BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL i I Usdy4ymene l Naa iheeug4l piafeis cery.wnR, (aY,an RWi tf �.. WdBr lH�nwe{,Txlfl }-,, r {Din•R a aPUonai .�' €araceune " Fa:aa Weephde 10 In, -t in. � ndEattdasure Pedv Plat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2)-23 (148.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cmZ) — 23 (148.4 cm') square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 nun) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 6 of 11 T1 ADHESIVE PLACEMENT DETAIL # 2 F„'" Flat/Low Profile Tile 1. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) - 12 (77.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 M AMMADE COUNTY ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm2) - 19 (122.6 cmZ) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 tendwiffO t a:4iM o fi, lain. "-•;�;�, Flattkow PraflleTlle paddyendffib7e Eave aamre Medium Pro0leTlle On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x V (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 inZ (109.7-148.4 cmZ) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 in' (51.6-58.1 cin) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9 of 11 affitens lib ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) High ProflleTOe Him) 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x%" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cmZ) - 11 (71 cmZ) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm') - 9 (58.1 cmZ) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 Ule. Ea re dosure lmotarsimwnj ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Remore top portion of the eaw course corer tile. Abut to secand worse of pan tiles. Ensure save end of pen and Caner taes are f lush ateave fine. Two Piece Barrel -High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) milers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11 MIAMIZADE Em DEPARTMENT OF REGULATORY AND ECONOM BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NO: Boral Roofing, LLC 7575 Irvine Center Drive Suite 100 Irvine, CA 92618 SCANNED BY St. Lucie County MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Sheet, Room208 (RER) Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 APR 2 3 2019 ST. Lucie County, Permitting SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Bermuda Concrete Flat Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approve(P", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. / cj p - O5--Z-y ADVERTISEMENT: The NOA number preceded by the words Mia>@ ) #QoEDRd followed by the expiration date may be displayed in advertising literature. If any pdQQ®S QoMftl4AIfte shall be done in its entirety. ST. LUCIE COUNTY INSPECTION: A copy of this entire NOA shall be provided to the user by the or its distributors and shall be available for inspection at the job site at the request of the Building Official. 60�- This NOA revises NOA No. 16-0112.07 and consists of pages 1 through 6. The submitted documentation was reviewed by Freddy Semino 510 APPROVED J FILE COPY NOA No.19-0220.06 Expiration Date: 06/07/21 Approval Date: 04/11/19 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Bermuda Flat Concrete Roof Tile, as manufactured Boral Roofing, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Bermuda Flat Concrete Tile Length = 16" Width= 10" Trim Pieces 1= varies w = varies varying thickness 2.1 MANUFACTURING LOCATION 1. Okeechobee, FL 2.2 EVIDENCE SUBMITTED Test Asencv Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Test Specifications Product Description TAS 112 Flat profile, interlocking, high pressure extruded Type 3a concrete roof file equipped with two nail holes. Class III For mechanical, mortar or adhesive set applications. TAS 112 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Identifier Test Name/Report Date 7161-03 Static Uplift Testing Dec. 1991 Appendix III PA 102 & PA 102(A) 94-084 Static Uplift Testing May 1994 PA 101 (Mortar Set) 94-060A Static Uplift Testing March, 1994 PA 101 (Adhesive Set) 25-7094-2 Static Uplift Testing PA 102 Oct. 1994 (4" Headlap, Nails, Direct Deck, New Construction) 25-7094-8 Static Uplift Testing PA 102 Oct. 1994 (4" Headlap, Nails, Battens) 25-7094-5 Static Uplift Testing PA 102 Oct. 1994 (4" Headlap, Nails, Direct Deck, Recover/Reroof) 25-7183-6 Static Uplift Testing PA 102 Feb. 1995 (2 Quik-Drive Screws, Direct Deck) NOA No.19-0220.06 Expiration Date: 06/07/21 Approval Date: 04/11/19 Page 2 of 6 2.2 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date The Center for Applied Engineering, 25-7183-5 Static Uplift Testing Feb. 1995 Inc. PA 102 (2 Quik-Drive Screws, Battens) The Center for Applied Engineering, 25-7214-1 Static Uplift Testing March, 1995 Inc. PA 102 (1 Quik-Drive Screw, Direct Deck) The Center for Applied Engineering, 25-7214-5 Static Uplift Testing March, 1995 Inc. PA 102 (1 Quik-Drive Screw, Battens) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix Il PA 108 (Nail -On) Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 PA 108 (Nail -On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 PA 108 (Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of screw Sept. 1993 vs. smooth shank nails The Center for Applied Engineering, Project No. 307025 Wind Driven Rain Oct. 1994 Inc. Test #MDC-77 PA 100 Atlanta Testing & Engineering, Inc. R1.894 Physical Properties Aug. 1994 R2.894 PA 112 R3.894 Professional Service Industries, Inc. 395-40011-1 Physical Properties Feb 2004 PA 112 Celotex Corporation Testing Service 520109-1 Static Uplift Testing Dec. 1998 520111-4 PA 101 Celotex Corporation Testing Service 520191-1 Static Uplift Testing March 1999 PA 101 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 2004 Walker Engineering, Inc. Evaluation Calculations 25-7094 Feb 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584 December 25-7804b-8 1996 25-7804-4 & 5 25-7848-6 Walker Engineering,'Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations Restoring Moment, Mg March 2004 Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 Nutting Engineers 13343.1 TAS 112 05/06/08 American Test Lab of South Florida RT1210.02-15 TAS 112 12/17/15 RT0807.04-18 TAS 112 08/27/18 NOA No.19-0220.06 WMIAWDADECOUNTY= Expiration Date: 06/07/21 Approval Date: 04/11/19 Page 3 of 6 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may be required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Boral Bermuda `Flat' Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations. Table 1: Average Weight (VI) and Dimensions (I x w ) Tile Profile Weight-W (lb f) Length -I (ft.) Width-w (ft.) Bermuda Flat Tile 9.7 , 1.33 .833 Table 2: Aerodynamic Multipliers - 2 (W) Tile Profile X (ft3) Batten Application 2. (ft3) Direct Deck Application Bermuda Flat Tile 0.189 0.205 Table 3: Restoring Moments due to Gravity - M9 (ft.-Ibf) Tile Profile 3":12" 4":12" 5":12" 6":12" Greater than 7":12" Bermuda Flat Tile Battens Direct Deck Battens Direct Deck Battens I Direct Deck Battens Direct Deck Battens Direct Deck 6.53 6.97 6.43 6.86 6.29 6.71 6.14 6.54 5.97 6.35 NOA No.19-0220.06 Expiration Date: 06/07/21 Approval Date: 04/11/19 Page 4 of 6 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min.19/32" plywood) Battens Bermuda 2-10d Ring Shank Nails 30.9 38.1 17.2 Flat Tile 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails' 1 50.3 65.5 48.3 1 Installation with a 4" the headlap and fasteners are located a min. of 2%" from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mr (ft: Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Bermuda Flat Tile Adhesive 31.33 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 13,9 grams. 3M' 2-Component Foam Roof Tile Adhesive AH-160. Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mr (ft.-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Bermuda Flat 3W 2-Component Foam Roof Tile Adhesive AH-160 118.94 Tile 3M'" 2-Component Foam Roof Tile Adhesive AH-160 40.45 4 Lar a add lacement of 45 rams of 3M " 2-Component Foam Roof Tile Adhesive AH-160 5 Medium add placement of 24 grams of 31VI' 2-Component Foam Roof Tile Adhesive AH-160 NOA No.19-0220.06 Expiration Date: 06/07/21 Approval Date: 04/11/19 Page 5 of 6 5. LABELING All tiles shall bear the imprint or identifiable marldng of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". Bermuda Flat Concrete Tile LABEL (LOCATED ON UNDERSIDE OF TILE) ' BUILDING PERmn REQUIREMENTS: As required by the Building Official or the applicable Building Code in order to properly evaluate the installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit. PROFILE DRAWING Bermuda "FLAT' CONCRETE ROOF TILE 16' FIELD TILE 16' 7 TBICK BUTT TILE END OF THIS ACCEPTANCE NOA No.19-0220.06 MIAMMADE COUNTY Expiration Date: 06/07/21 FUTO I Approval Date: 04/11/19 Page 6 of 6