This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to he
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the A14J (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
APR 2 3 '019
DESCRIPTION: Turco Self -Adhering Modified Bitumen Roofing Systems over Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product
TERNMATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terntinate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA-
(
ADVERTISEMENT: The NOA number preceded, by the words Miami -Dade County, Florida, and followed bytheexpiration date may be displayed in advertising literature. If any portion of the NOA is di la then it shall be done
;n its entirety. R�/1���!l��AE��D'' 1FOpR�
INSPECTION: A copy of this entire NOA shall be provided to the user by the man rYM itWANCE
shall be available for inspection at the job site at the request of the Building Official. ST. LU CI E COUNTY
This NOA renews NOA No. 12-0703.06 consists of pages 1 through 10. BOCC-0
The submitted documentation was reviewed by Alex Tigem. .
M ECOUNTY NOA No.: 18-0919.04
' FILE �OF�prrationDate: 11/08/23
pproval Date: 10/25/18
Page I of 10
—firm P.OsoG1 vVC. 111 wr1 \-I P. R 64 I()
ROOFING SYSTEM APPROVAL
Ca o :
Roofing
Snb-Cateeorv'
Modified Bitumen
Material
SBS
Deck Tvpe•
Wood
Maximum Design Pressure: -60.0 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product Dimensions
LeakBarrier® 3' x 133'4" rolls
EasyLay
LeakBarrier' 3' x 72' rolls
EasyBase
LeakBarrier' 3' x 36' rolls
EasyStick Plus' t
LeakBarrier® 3' x 72' rolls
EasyTorch' SA
Base
Le"arrier" 39 3/8"
EasyTorch'" APP x 32' 10" rolls
Smooth
LeakBarrielm 39 3/8"
EasyTorcb APP x 32' 10" rolls
Granular
APPROVED INSULATIONS:
Product Name
Test Product
Specification Description
ASTM D 226 Mechanically attached, asphalt coated
Type H polyester base sheet.
ASTM D 4601, Type I Self -adhered, fiberglass reinforced, smooth
surfaced SBS modified bitumen base ply
membrane.
ASTM D 6164, Type I Self -adhered, polyester reinforced, granule
surfaced SBS modified bitumen cap ply
membrane.
ASTM D 4601 Self -adhered, glass fiber reinforced, smooth
Type H surfaced, SBS modified bitumen base ply
membrane.
ASTM D 6222, Polyester reinforced, smooth surfaced, APP
Type I modified bitumen torch applied cap membrane.
ASTM D 6222, Polyester reinforced, slate flake surfaced, APP
Type I modified bitumen torch applied cap membrane.
TABLE2
Product Description
SECUROCK Gypsum -Fiber Roof Board Rigid, gypsum -based board stock
MUU11•DADECOUNTY
,.... my
Manufacturer
(With Current NOA1
United States Gypsum
Corporation.
NOA No.:18-0919.04
Expiration Date: 11/08/23
Approval Date: 10/25/18
Page 2 of 10
APPROVED FASTENERS:
Fastener Product
Number Name
1. #12 Standard Roofgrip,
OMG Heavy Duty
TABLE 3
Product
Description Dimensions
Roofing and insulation fasteners, Various
with #3 Phillips head.
2. OMG 3" Galvalume Steel Galvalume steel stress plates. 3" round
Plate
3. Trufast #12 DP Fastener Insulation fastener for wood,
steel and concrete
4. Trufast #14 HD Fastener Insulation fastener for wood,
steel and concrete
5. Trufast 3" Metal Insulation Galvalume steel stress plate 3" round
Plate
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report
Southwest Research 10.16924.01.220a ASTME108
Institute 10.16924.01.220b ASTM E108
Trinity I ERD
NEMOjetc.
T39040.11.11-R1
T43940.05.13-R1
T43410.05.13-RI
T35450.12.11-R1
TAR-SC13965.02.17-RI
TAR-SC16545.11.17
4-TAR-18-002.04.18
TAS 114 (H)
ASTM D6222 / TAS 110
ASTM D4601
ASTM D6222 / TAS 110
ASTM D226
ASTM D4601
ASTM D6164 / TAS 110
Manufacturer
(With Current NOA)
OMG, Inc.
OMG, Inc.
Altenloh, Brinck & Co.
U.S., Inc.
Altenloh, Brinck & Co.
U.S., Inc.
Altenloh, Brinck & Co.
U.S., Inc.
Date
11/02/12
11/02/12
11/21/11
05/01/13
05/23/13
6/02117
02/27/17
11/01/17
04/16/18
MIAMFDADE COUNTY
NOA No.: 18-0919.04
. • • • . , Expiration Date: 11/08/23
Approval Date: 10/25/18
Page 3 of 10
APPROVED ASSEMBLIES
Membrane Type: SBS
Deck Type 11- Wood, Insulated
Deck Description: 19/32 or greater plywood or wood plank attached with 8d common nails spaced 6" o.c. at wood
joists spared maximum 24" o.c.
System Type C(1): All layers of insulation are mechanically attached to roof deck
All General and System'Limitations apply.
One or more layers of the following:
Insulation Laver Insulation Fasteners Fastener
Table 3 Density/fe
SECUROCK Gypsum -Fiber Roof Board
Minimum 3/8" thick 1 (#12), 2. 3, 4, 5 1:1 fe
Note: Base layers of insulation shall be mechanically attached using the fastener density listed. The insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Base Sheet: One ply ofLeakBarrier®EasyBase self -adhered.
Ply Sheet: (Optional) One ply of LeakBarrier®EasyBase self -adhered.
Cap Sheet: One ply of LeakBarrier®Easysticr Plus self -adhered.
Surfacing: (Optional) Install one of the following to obtain required fire classification. Any coating, listed
below, used as a surfacing, must be listed within a current NOA.
1. Gravel or slag at 400 lbs/sq or 300 lbs/sq, respectively, in a flood coat of approved
asphalt at 60 lbs/sq.
2. Karnak 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum
Roof Coating at 1 % gal/sq.
Maximum Design -52.5 psf (See General Limitation #7.)
Pressure:
NOA No.: 18-0919.04
Expiration Date: 11/08/23
Approval Date: 10/25/18
Page 4 of 10
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d common nails spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type C(2): All layers of insulation are mechanically attached to roof deck.
All General and System Limitations apply.
One or more layers of the following:
Insulation Laver Insulation Fasteners Fastener
SECUROCK Gypsum -Fiber Roof Board able 3 Density/112
Minimum 3/8" thick 1 (#12),2,3,4,5 1:1 if
Note: Base layers of insulation shall be mechanically attached using the fastener density listed. The insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment
Base Sheet: One ply ofLeakBarrier®EasyBase self -adhered
Ply Sheet: (Optional) One ply LeakBarrier® EasyTorcW' SA Base self -adhered or one ply of
LeakBarrier®EasyTorchTM APP Smooth, torch applied.
Cap Sheet: One ply of LeakBarrief®EasyTorcN" APP Granular, torch applied.
Surfacing: (Optional) Install one of the following to obtain required fire classification. Any coating, listed
below, used as a surfacing, must be listed within a current NOA.
1. Gravel or slag at 400 Ibs/sq or 300 lbs/sq, respectively, in a flood coat of approved
asphalt at 60 Ibs/sq.
2. Karnak 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum
Roof Coating at 1'/2 gal/sq.
Maximum Design -52.5 psf (See General Limitation #7.)
Pressure:
APPROVED
NOA No.: 18-0919.04
Expiration Date: 11/08/23
Approval Date: 10/25/18
Page 5 of 10
Membrane Type: SBS
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d common nails spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type D(1): All layers of insulation are mechanically attached to roof deck.
All General and System Limitations apply.
One or more layers of the following:
Insulation Laver Insulation Fasteners Fastener
able 3 Density/W
SECUROCK Gypsum -Fiber Roof Board
Minimum 3/8" thick N/A N/A
Base Sheet: One or more plies of LeakBarrier® EasyLay', mechanically attached 10" o.c, in the min. 4"
lap and 10" o.c, in two, equally spaced, staggered center rows with #12 Standard Roofgrip or
OMG Heavy Duty fasteners with OMG 3" Galvalume Steel Plates.
Ply Sheet: One ply of LeakBarrier® EasyBase' self -adhered.
Cap Sheet: One ply ofLeakBar ier®EasyStick Plus self -adhered.
Surfacing: (Optional) Install one of the following to obtain required fire classification. Any coating, listed
below, used as a surfacing, must be listed within a current NOA.
1. Gravel or slag at 4001bs/sq or 300 lbs/sq, respectively, in a flood coat of approved
asphalt at 60 Ibs/sq.
2. Karnak 97 Fibmted Aluminum Asphalt Roof Coating or Asbestos Free Aluminum
Roof Coating at 1'/: gal/sq.
Maximum Design -60 psf (See General Limitation #7.)
Pressure:
NOA No.: 18-0919.04
Expiration Date: 11/08/23
Approval Date: 10/25/18
Page 6 of 10
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19732° or greater plywood or wood plank attached with 8d common nails spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type D(2): All layers of insulation are mechanically attached to roof deck.
All General and System Limitations apply.
One or more layers of the following:
Insulation Laver
SECUROCK Gypsum -Fiber Roof Board
Insulation Fasteners Fastener
able 3 Density/fO
Minimum 3/8" thick N/A NIA
Base Sheet: One or more plies of LeakBarrier® EasyLay'", mechanically attached 10" o.c. in the min. 4"
lap and 10" o.c. in two, equally spaced, staggered center rows with #12 Standard Roofgrip or
OMG Heavy Duty fasteners with OMG 3" Galvalume Steel Plates.
Ply Sheet: One ply of LeakBarrier® EasyTorch' SA Base splf-adhered or one ply of LeakBarrier®
EasyTorch APP Smooth, torch applied.
Cap Sheet: One ply of LeakBar ier® EasyTorch' APP Granular, torch applied.
Surfacing: (Optional) Install one of the following to obtain required fire classification. Any coating, listed
below, used as a surfacing, must be listed within a current NOA_
1. Gravel or slag at 400 lbs/sq or 300 lbs/sq, respectively, in a flood coat of approved
asphalt at 60 lbs/sq.
2. Karnak 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum
Roof Coating at 1 %s gallsq.
Maximum Design -60 psf (See General Limitation V.)
Pressure:
NOA No.: 18-0919.04
Expiration Date: 11/08/23
Approval Date: 10/25/18
Page 7 of 10
Membrane Type: SBS
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank attached with 8d common nails spaced 6" o.c. at wood
joists spaced maximum 24" o.c_
System Type E(1): Base sheet mechanically fastened.
All General and System Limitations apply.
One ply of LeakBarrier® EasyLay' fastened to the deck as described below.
OMM Attach base sheet using 12 ga. annular ring shank nails with min. 32 ga., 1-5/8" diameter tin -
caps spaced 7" o.c. in the 4" lap and 7" o.c. in three, equally spaced, staggered center rows.
Fastening #2: Attach base sheet using #12 Standard Roofgrip or OMG Heavy Duty fasteners with OMG 3"
Galvalume Steel Plates or Trufast #12 DP or Trufast #14 HD Fasteners with Trufast 3" Metal
Insulation Plates spaced 10" o.c. in the min. 4" lap and 10" o.c. in two, equally spaced,
staggered center rows.
One ply of LeakBarrierl FasyBase' self -adhered.
One ply of LeakBarrier® EasyStick Plus' self -adhered.
Surfacing: (Optional) Install one of the following to obtain required fire classification. Any coating, listed
below, used as a surfacing, must be listed within a current NOA.
1. Gravel or slag at 400 lbs/sq or 300 lbs/sq, respectively, in a flood coat of approved
asphalt at 60 lbs/sq.
2. Karnak 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum
Roof Coating at 1'/2 gal/sq.
Maximum Design -60 psf (See General Limitation #7.)
Pressure:
NOA No.: 18-0919.04
Expiration Date: 11/08/23
Approval Date: 10 5/18
Membrane Type: SBS/APP
Deck Type 1I: Wood, Non -Insulated
Deck Description: 19432" or greater plywood or wood plank attached with 8d common nails spaced 6" o.c. at wood
joists spaced maximum 24" o.c.
System Type E(2): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of LeakBarrier® EasyLay'a fastened to the deck as described below.
Fastening #1: Attach base sheet using 12 ga. annular ring shank nails with min. 32 ga., 1-518" diameter tin -
caps spaced 7" o.c. in the 4" lap and 7" o.c. in three, equally spaced, staggered center rows.
Fastening #2: Attach base sheet using Trufast #12 DP or Trufast #14 HD Fasteners with Trufast 3" Metal
Insulation Plates spaced 10" o.c. in the min. 4" lap and 10" o.c. in two, equally spaced,
staggered center rows.
Ply Sheet
One ply of LeakBarriet'a EasyTorchm SA Base self -adhered or one ply of LeakBarrier®
EasyTorchTm APP Smooth, torch applied.
Cap Sheet:
One ply of LeakBarrier® EasyTorchTm APP Granular, torch applied.
Surfacing:
(Optional) Install one of the following to obtain required fire classification. Any coating, listed
below, used as a surfacing, must be listed within a current NOA.
1. Gravel or slag at 4001bs/sq or 300 lbs/sq, respectively, in a flood coat of approved
asphalt at 60 lbs/sq.
2. Karnak 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum
Roof Coating at 1'/2 gal/sq.
Maximum Design
-60 psf (See General Limitation #7.)
Pressure:
nwnuoaoe couornr NOA No.: 18-0919.04
Expiration Date: 11/08/23
Approval Date: 10/25/18
Page 9 of 10
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LimrrATIoNs:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2_ Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbsJsq.
Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf.
S. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be
submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing
Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and comer areas shall -comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with'Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred
within this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter milers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and 'applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
MIAMMADE COUNiY NOA No.: 18-0919.04
Expiration Date: 11/0Sl23
Approval Date: 10/25/18
Page 10 of 10
MIAMI.OA6E
av
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DMSION
M
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 209
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.eov/econRm1
TAMKO Building Products, Inc. RECEIVED SCANNED
220 West 4th Street BY
Joplin, MO64801 APR 2 3 2019 St. Lucie County
SCOPE: ST. Lucie County, Permittinn
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: TAMKO Roof Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety. �q �, A4 a FOR
INSPECTION: A copy of this entire NOA shall be provided to the user b�e manufacturer or-its-diStM T end
shall be available for inspection at the job site at the request of the Building Ol&ial. " r N'�
.s +e
This NOA revises and renews NOA Ne.14-0306.02 and consists of pages 1 through 6.
The submitted documentation was reviewed by Gaspar J Rodriguez.
MIAMI•DADECOUNTY
i
NOA No.:15-0709.19
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Asphalt Shingles
Materials:
Laminate
Deck Type:
Wood
SCOPE
This approves TAMKO's Heritage, Heritage Woodgate and Heritage Premium asphalt shingles, manufactured by
TAMKO Building Products, Inc., as described in this Notice of Acceptance and designed to comply with the Florida
Building Code High Velocity Hurricane Zones.
PRODUCT DESCRIPTION
Product
Dimensions Test
Product Description
Specifications
Heritage
13 %4 " x 39'/8" TAS 110
Dimensional asphalt shingle.
Manufacturing Location # 1, 2, 3
Heritage Woodgate
13 %4 "x 39'/s" TAS 110
Dimensional asphalt shingle.
Manufacturing Location # I
Heritage Premium
13 % " x 391/8" TAS 110
Dimensional asphalt shingle.
Manufacturing Location # 1, 2
MANUFACTURING LOCATIONS
1. Dallas, TX
2. Tuscaloosa, AL
3. Frederick, MD
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
Underwriters Laboratories, Inc.
TAS 107 & UL 790
04CA44252
02/25/05
ASTM D3462
02NK33813
09/23/02
ASTM D 3462 & TAS 107
R2919 Letter
03/10/11
ASTMD3462
4789110543
08/26/14
TAS 107
02/19/15
ASTM E 108
08/26/14
ASTM D3161, Class F
4787043752
10/20/15
PRI Asphalt Technologies, Inc.
TAS 100
TAP-129-02-01
05/26/05
TAS 100
TAP-130-02-01
05/26/05
TAS 100
TAP-131-02-01
05/26/05
TAS 100
TAP-303-02-01
12/12/14
TAS 100
TAP-307-02-01
02/10/15
TAS 100
TAP-317-02-01
09/02/15
MIAMMADE COUNTY NOA No.:15-0709.19
Expiration Date: 12/01/20
Approval Date: 11/12/15
Page 2 of 6
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shingles shall not be installed on roof mean heights in excess,of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
INSTALLATION
I. Shingles shall be installed in compliance with Roofing ApplicationStandard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115.
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Details 'B', attached.
LABELING
Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of manufacturing
facility, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade
County Product Control Seal as seen below:
MIAMl-DADE COUNTY
BUILDING PERMIT REQUIREMENTS
As required by the Building Official or the applicable Building Code in order to properly evaluate the
installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit.
MAW DADE COUNTY NOA No.: 15-0709.19
Expiration Date: 12/01/20
Approval Date:11/12/15
Page 3 of 6
DETAIL A
HERITAGE, HERITAGE WOODGATE, AND HERITAGE PREM UM
All dimensions are In inches.
STH COURSE
4TH COURSE
3RD COURSE
2ND COURSE
— 23
1ST COURSE
zs
Fun
1 1 :
HERITAGE SBMXGLE
FIG. I FASTENING PATTERN
All dimensions are in inches
- 39-3/8"
•
7'�' �I< 7'/="—� 7 3/e" 7 F'" 7'�" 1"
13
----------I ----------SIG ---- --
-------------------------------------------------
C
E
1/4"
-5/8"
KPOSUfe
MIAMMM=E COUNTY NOA No.:15-0709.19
' Expiration Date: 12/01/20
Approval Date:11/12115
Page 4 of 6
DETAIL B (CONTINf7ED)
HERITAGE SHINGLE
FIG. 2 ALTERNATE FASTENING PATTERN
ttl"It':
12•Il?."—.; + 1?-t12"-r(;:1"�w
i
!
Q Common Boni
I
FASTENERS
;
_
� m
1
m�
�a
1
� x
L�
s
..
39_3/8"
HERITAGE SHINGLE
(TUSCALOOSA, AL)
FIG. 3 ALTERNATE FASTENING PATTERN
HORIZONTAL NAIL SPACING IN ACCORDANCE WITH FIG. 1 OR FIG. 2.
VERTICAL NAIL SPACING ALLOWED ANYWHERE WITHIN NAIL ZONE.
PAINT
LINE,_
.y
7-718 T _ NAILZONE
6-118e
DO NOT FASTEN
ALONG EDGE OF
COMMON BOND
PREFERRED
FASTENER
LOCATION
WALMA)ADE COUNTY NOA No.:15-0709.19
• • • Expiration Date: 12/01/20
Approval Date: 11/12/15
Page 5 of 6
ai
HERITAGE WOODGATE & HERITAGE PREMIUM SHINGLES
FIG. 4 FASTENING PATTERN
All dimensions are in inches
1° 7'/z" 6'/2" 6 931e° '/:° ' °
6IE— 3IE 3IE 3I� �I� ,7/ �IH
13
:------•-------:--------------------- ---------------------------- ------
END OF THIS ACCEPTANCE