HomeMy WebLinkAboutROOF PAPERWORKInverter Type: Solaredge
PV Panel:
(9) Mission 310W
Racking:
Iron Ridge
Total Wattage:
2,790W
Roof Type:
Composition Shingles
Wind Load:
7 to 27 Deg
Fastener Type:
Use 5/16" Dia 4" Lags
Sheet Index
S-1
Cover Sheet / Site Plan
S-2
Detail
E-1
One - Line
S-lA
Mounting Plan
General Notes:
-SolarEdge SE3000H-US Inverter
located near utility meter
-SolarEdge P320 Optimizers
are located on roof behind each module.
-First responder access maintained and
from adjacent roof.
-Wire run from array to connection is 60 feet.
Z
C. Nao��/���i� Godwin Engineering and
y Design, LLC
* so * 8378 Foxtail Loop
IX Pensacola, FL 32526
OF D. Chad Godwin, PE
//ChaNd@godwineng.com
Legend ® Chimney
® First responder access A, Satellite
Utility Meter O Vent Pipe
EPPV Disconnect F711 SolarEdge Inverter
-COGEN Disconnect
Located adjace
Utility meter
-SolarEdge 30(
Inverter
TU:I:s. A4_+..—
FRONT OF HOUSE
Layout Subject to Change Based on Site Conditions
Represents all Fire Clearance 1st Responder Access
including Alternative methods minimum of 36" unobstructed as per
Section R324 of the 2015 IRC
2017 FL Residential Code,6th Edition (2015 International Residential Code - 2nd Printing
modified by the FL Building Standards and Codes 2017 Uniform Code Supplement), 2015
International Energy Conservation Code, County of St Lucie Code, 2014 National Electric Code.
Customer Info:
Ernest Joseph
2806 Kingsley Dr,
Fort Pierce, FL SCANNED
34946 BY
772-882-0762St.
ST.LUCIE COUNTY
PLAN REVIEW
BLDG:
DATE: kW
ELE'
DATE: 9C 7--19
PLUMB:
DATE:
MECH:
DATE:
R-1
# Modules (9)
Pitch: 20'
Azimuth: 180'
5 1 1
-61
EHS
1� Efficient Home Services
9416 International Ct,
St. Petersburg, FL 33716
844-778-8810
Date: 4.12.19
Drawn bv: TP
I Rev Date: I
S-1
11
9
kwRickb XR 100 Rail
¢sad C&ar
100 Rail
General Notes:
- L Feet are secured to roof rafters.
@ 48" O.C. using 5/16" x 4" stainless
steel Lag bolts.
- Subject roof has One layer.
- All penetrations are sealed and flashed.
3/6-16 X 3/4
HEX HEAD BOLT
3/6-16
FLANGE NUT
Roof Section
Pitch
Roof Rafter
and Spacing
Overhang
Notes:
R1
4/12
211x4" @
24 O.C.
22"
Generic Truss
Desi ned as er ASCE7-10 Inverter Type: Solaredge
g p PV Panel: (9) Mission 310W
Racking: Iron Ridge
Total Wattage: 2,790W
Modules mounted flush to roof Roof Type: Composition Shingles
Wind Load: 7 to 27 Deg
no higher than 6 above surface. Fastener Type: Use 5/16" Dia 4" Lags
Customer Info:
Ernest Joseph
2806 Kingsley Dr,
Fort Pierce, FL
34946
772-882-0762
Solve Module
Godwin Engineering and
Design, LLC
8378 Foxtail Loop
Pensacola, FL 32526
D. Chad Godwin, PE
Chad@godwineng.com
3-5/819
C. GO��//i
O�
o; z
1360 `
*
TA E OF ' k! zz
0n�. ' �� ORIOP •' �����
EH S
Efficient Home Services
9416 International Ct,
St. Petersburg, FL 33716
844-778-8810
Date: 4.12.19
Drawn bv: TP
I Rev Date:
S-2
SolarEdge
Power Optimizer
Load Side Connection
Bu"L Rahn
p
Main Breaker Size
200
Bus Rahn 1.2-Main Break Si.
40
Max Allowable Load Side
1 40
Load Sim Breaker Size
1 20
8 9
S T"
r>o
(4) #10 AWG Wire
(1) #8 EGC
In 3/4" EMT type or
FMC,PVC, LFNC
(depending on route to
inv. Metal if interior)
Main Service
200A
200A Bus
IIIAWGWW
r, 0a
lnNa 4
W/4'
Iry .3C C�vl
Optional load side connection (when available)
Per 705.12(A)
In Case of Emergency Call
Efficient Home Services
at 844-778-8810
Equipment list
PV:
(9) MSE310SQ8T
(9) SolarEdge Power Optimizer P-320
(1) string of (9)
Inverter:
(1) SolarEdge SE3000H-US
SolarEdge AC/DC Safety Switch
AC Disconnect:
60A Fused Service Rated Disconnect
All wiring to meet the 2014 NEC and
2015 Energy Code
Inverter Output Ckt
To Overcurrent Protection Device
AC Max Output Current
12.5
AC Max Output Current * 1.25%
15.6
Overcurrent Protection A
20
No. of Current Carrying Cond
<4
Conductor Gauge AWG
10
SolarEdge Inverter
SE3000H-US-U
w/Integrated Disconnect
60A Service Fused
Rated Disconnect
Neutral to Ground Bond
-�
#10 L1,L2 & neutral
#10 Ground
In 3/4" Conduit
Note:
-All wiring to meet the 2014 NEC and
2015 Energy Code
60A Fused Service Rated Disconnect
-Type of conduit to be determined
on site by contractor.
Must be metal if DC ran interior.
Inverter Type:
PV Panel:
Racking:
Total Wattage:
Roof Type:
Wind Load:
Fastener Type:
#10 L1,L2 & neutral
In 3/4" Conduit
Main Distribution Panel
200A Main
LI L2 N
Line Side
PHOTOVOLTAIC SYSTEM
EQUIPPED WITH
RAPID SHUTDOWN
PHOTOVOLTAIC SYSTEM DC DISCONNECT
MAX POINT CURRENT: 8A
MAX POWER POINT VOLTAGE: 350 VDC
MAX SYSTEM VOLTAGE: 480 DC
MAX CIRCUIT CURRENT: 15 A
ELECTRIC SHOCK HAZARD
IF GROUND FAULT IS INDICATED ALL
NORMALLY GROUNDED
CONDUCTORS MAY BE UNGROUNDED
AND ENERGIZED
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH THE LINE AND
LOAD SIDES MAY BE ENERGIZED IN
THE OPEN POSITION
ELECTRIC SHOCK HAZARD
THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE
UNGROUNDEDANDMAYBE
ENERGIZED
WARNING
DUAL POWER SUPPLY
SOURCES: UTILITY GRID AND PV
SOLAR ELECTRIC SYSTEM
Apply to DC
disconnect/inverter
Apply to Inverter
Apply to Disconnects
Apply to each J box, combiner box,
disconnect,and device where
energized, ungrounded circuits
maybe exposed during service.
Apply to MSP
Apply to Disconnects
Tap M Godwin Engineering and
hl
Design, LLC
8378 Foxtail Loop
Pensacola, FL 32526
D. Chad Godwin, PE
Chad@godwineng.com
(IPIOAWG EGC & GEC
Solaredge
(9) Mission 310W
Iron Ridge
2,790W
Composition Shingles
7 to 27 Deg
Use 5116" Dia 4" Lags
Customer Info:
Ernest Joseph
2806 Kingsley Dr,
Fort Pierce, FL
34946
772-882-0762
Date:
Drawn
' #%, �c goo
o, 8 360
_ 1 _
1
1
cCORIDP.%
N _
E H S
_lam Efficient Home Services
9416 International Ct,
St. Petersburg, FL 33716
844-778-8810
4.12.19
TP
I Rev Date: I
17'
71 �
i
4
Splice Bar
Flashings
UFOs
Sleeves/End Caps
Solardecks
Ground Lugs
ON
2
17
20
4
1 Inverter Type:
PV Panel:
1 Racking:
Total Wattage:
Roof Type:
Wind Load:
Fastener Type:
R-1
# Modules (9)
Pitch: 20°
Azimuth: 180°
Max cantilever is 16" as per manufacturer spec.
Max Cantilever = Max Span * (3)=48*(3)=16"
Solaredge
(9) Mission 310W
Iron Ridge
2,790W
Composition Shingles
7 to 27 Deg
Use 5/16" Dia 4" Lags
Customer Info:
Ernest Joseph
2806 Kingsley Dr,
Fort Pierce, FL
34946
772-882-0762
5t �6tt
Godwin Engineering an
Design, LLC
8378 Foxtail Loop
Pensacola, FL 32526
D. Chad Godwin, PE
Chad@godwineng.com
It
so
A OF
j�FS• c�ORIDP.•G�2\���
S/ONA1III I1�W//S/#
731.16EH S
_L Efficient Home Services
9416 International Ct,
St. Petersburg, FL 33716
844-778-8810
4.12.19
TP
Rev #: 00 1
Rev Date: 1
S-1A
U:1 SWAY
PLKC 6U
CLASS LEADING 300-31OW
C ER.TTFICA'FLON SS&. TE`!TS
3`0 &�,3
CLASS LEADING POWER OUTPUT
18,65%.
MAXIMUM EFFICIENCY
POSITIVE'P(jW ERrTOLERANCE-
High_Power;'Ameciean' Qualtj!
Mission Solar Energy is headquartered In San Antohio,TX with module_
acilities onsite. We produce American quality podlicts ensuring the`
)ighest power output and reliability, to our customers: Our,pr6 2 elineP.
'swell suitedi for resioeobal; eoinroercial anl3utility applications: Every
Mission Solar Energy product'is certified and surpassesiodustry
pandard regulations, proving eiccellent performance over the long-term.
Iwww.mjssionfolarcom• ], info@missionsolar.com
CERTIFIED RELIABILITY
) Tested to UL1703 & IEC standards
) PID Resistant
SUPERIOR AESTHETICS
) All -black design coupled with outstanding power output
) Ideal for residential & commercial applications
EXTREME WEATHER RESILIENCE
) 5631 Pa snow load (117 psf) tested load to UL1703
) 185 mph wind rating"
BAA COMPLIANT FOR GOVERNMENT PROJECTS
) Buy American Act
) American Recovery & Reinvestment Act
Electrical Parameters at Standard Test Conditions (STC)
Nludule Type-. MSE300SQ8_T; MSE3055QBTh r_MSE310SQ8T_
Power Output Pmax Wp r 300 305 310
Mnriuld Fffiri6nr4, - Zr
Tolerance
0-+3%
0-+3%
0-+3%
15hortGrcutf6urrent
•Isc
Aj
9574
9(664.
976o
Open Circuit Voltage
Voc
V
40.08
40.10
4012
Rated Cument
: •I4
A-.
_ -9 058`�
_ 9:202 •
_ y9 345 _,4
Rated Voltage
Vmp
V
33.12
33.14
33.17
FuseRatiiig:
�15
•20+
Normal Operating CellSeinpeiatuie (NOCn:. 46.094E lie°C)•
Temperature Coefficient of Pmax -0.3779'/°C
Tem"p'erature;Coetfi4ienfof,Y61C T;280%/°C:-i�
Temperature Coefficient of Isc 0.039%/°C
MaitimumSystem Voltage- � lyl)00VDC;
Operating Temperature Range -40=C (-40=F) to +85-C (185-F)
Maximum Series Fuse Rating 20�1
25-YEAR 12-YEAR Fire Safety Classification ClassC
Front & Back Load (ULstanda`rd) 5631 Pa (117psf)
LINEAR WARRANTY PRODUCT WARRANTY 1_. ......
Tested IoadRo UL-1703�stsndard�-
Hail Safety Impact Velocity 25mm at 23 m/s
YEARS
CERTIFICATIONS
IEC61215/IEC61730/IEC61701 UL1703
O L gSus Pow' bard CEC
LISTED
'As there are different certification requirements indifferent markets, please contact y<
Mission Solar Energy sales repnesentafive for the specific certificates applicable to the I
the region In which the products are to be used.
'185 mph wind rating based upon Installation at 300 or less fixed Hit mount
MISSION SOLAR
ENERGY �
Solar Celia;
P-type.Mono-uystalhne Sillco_n(15675_min)'
Cell orientation
60 cells (6x10), 5 busbar
E-•
Module dimension
1669min099mmx40mm
1 -- -
(651S1mx 39 33'iii x 1.57in:) -
Weight
18.2 kg (40.1 lb)
Front Glass.
32mm (0126 in!)`tempued;�
4_ _ _ . _
Lovy;iron Antl reflecttye coating , _ _- _ ,.--, _,
Frame
Anodized aluminum alloy
incapsulant.
Ethylene wnyl aiieFate(EVA)'
J-Box
Protection class IP67 with 3 bypass -diodes
Ca61els.
-pV,wire, lm (39,3Z in,),.4mIn2 /.12 QWG - -
Connector
MCA
7ZONE
I ontauier FT Pallets Panels 305w
53'
Double stack 36
936
285.48 kW
40'
Double stack; -2-8
728•
222.64 kW.
Panels Weight
Height
Width Length
Pallet
26 111051bs
45.5W
45.5011 67.00'
61215/ 61730/ 61701
UL 1703 listed
Fg�pw Po G7 CEC
MSE305SQ8T: 305WP, 60CELL SOLAR MODULE
CURRENT -VOLTAGE CURVE
Cells Temp.-25-C
Incidentlrrd.1,000 3W/m-
305.1 W
g
Incident
drrd.= 800 tW/m
g
2 Jw
c
s
I
Incidentlrrd=600
— ?W/m
1 W,
p
2.1
l
IwIm
Incident
Irrd.=400
a
22
I
Incident
'Irrd: 200 rW/lp
=
58.
it
o
m
>a
u
Voltage M
Current -voltage characteristics with dependence on irradiance
and module temperature
BASIC DESIGN (UNITS: mm)
Front View
}
orem w
Male m>.
i�
mxoo
Mounimg Hcre I—r
Hoe
Bum
lio)
eeaao —
Back View
�4PV_1 A,
MISSION S13LAR
ENERGY o4
Mission Solar Energy reserves the right to make specification changes without notice
nnrnururar_¢eo.uvrntmlo wFln¢inu nem:� nrm¢inu an
Mission Solar Energy 18303 S. New Braunfels Ave., San Antonio, Texas 78235
Single.Phase I nverter Z:
with HD -Wave Te.chnol-o C
_ _ gy m
for North America
SE3000H-.US /'SE3800H=US / SE5000H US / SE6000,H US- /
SE7600H-.US / S:EI OOOOH US / SE11140.OH US.
O SolerlS--- .HD ce
tj LA
IO solar= _HD.. O
67 p
0000 sees
/
O tl
0 Y i is.
O Oa' .. 0
Optimized installation with HD -Wave technology
/ Specifically designed to work with
power optimizers
/ Record -breaking efficiency
/ Fixed voltage inverter for longer strings
/ Extremely small
/ Built-in module -level monitoring
/ Outdoor and indoor installation
/ Integrated arc fault protection and rapid shutdown for / Optional: Revenue grade data, ANSI C12.20
NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy)
/ UL1741 SA certified, for CPUC Rule 21 grid
compliance
/ Single Phase Inverter
Wit HD -Wave Technology for North America
SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/
SE760OH-US / SE10000H-US / SE1140OH-US
Rated AC Power Output
3000
3800 @ 240V
3300 @ 208V
5000
6000 @ 240V
5000 @ 208V
7600
10000
11400 @ 240V
10000 @ 208V
VA
Maximum AC Power Output
3000
3800 @ 240v
3300 @ 208V
50005000
6000 @ 240V
@ 208V
7600
1000D
11400 @ 240V
10 M @ 208V
VA
AC Output Voltage Min: Nom.-Max
(211- 240 - 264)
11
Vac
AC Output Voltage Min.-Nom: Max.
(183 - 208 - 229)
_
-
-
`'
Vac
AC Frequency (Nominal)
59.3 - 60 - 60.50
Hz
Maximum Continuous Output
Current @240V
12.5
16
21
25
32
42
47.5
A
Maximum Continuous Output
Current@208V
16
24
-
-
48.5
A
GFDI Threshold
7
A
Utility Monitoring, Islanding
Protection, Country Configurable
Thresholds
Yes
INP.l7T
Maximum DC Power @240V
4650
5900
7750
9300
11800
15500
1 17650
W
Maximum DC Power @2C8V
-
5100
-
7750
-
-
15500
W
Transformer -less, Ungrounded
Yes
Maximum Input Voltage
480
Mdc
Nominal DC Input Voltage
380
400
Vdc
Maximum Input Current @240W+
8.5
10.5
13.5
16.5
20
27
30.5
Adc
Maximum Input Current @208VM
-
9
-
13.5
-
-
27
Adc
Max Input Short Circuit Current
45
Adc
Reverse -Polarity Protection
Yes
Ground -Fault Isolation Detection
600ka Sensitivity
Maximum Inverter Efficiency
99 99.2
%
CEC Weighted Efficiency
99
99 @ 240V
98.5 @ 208V
%
Nighttime Power Consumption
< 25
W
ADDITIONALFEATIjRES.
Supported Communication interfaces
R5485, Ethernet, ZgBee (optional), Cellular (optional)
Revenue Grade Data, ANSI C1220
Optionalw
Rapid Shutdown - NEC 2014 and
2017 690.12
Automatic Rapid Shutdown upon AC Grid Disconnect
[STANDARD COMPLIANCE
Safety
UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to TILL M-07
Grid Connection Standards
IEEE1547, Rule 21, Rule 14 (HI)
Emissions
FCC Part 15 Class B
dNSTALLATION SPECIFICATIDNS
AC Output Conduit Size / AWG
Range
3/4' minimum / 14-6 AWG
3/4' minimum /14-4 AWG
DC Input Conduit Size / u of Strings /
AWG Range
3/4' minimum / 1-2 strings / 14-6 AWG
3/4' minimum / 1-3 stings / 14-6 AWG
Dimensions with Safety Switch
(HxWXD)
17.7 x 14.6 x 6.8/ 450 x 370 x 174
213 x 14.6 x 7.3/ 540 x 370 x 185
in/
mrn
Weight with Safety Switch
22/10 25.1/11.4 1 26.2/11.9
38.8/17.6
Ib/kg
Noise
< 25 1 <50
dBA
Cooling
Natural Convection
Operating Temperature Range
-40 to .140 / -25 to +60r� (-40'F / -40'C option)w
'F /'C
Protection Rating
NEMA 4X (Inverter with Safety Switch)
�^ For other regional settings please mntao SolarEdge support
•sola=@@ • Revenue
grade
Inverter Pmay/N: m used; the inverter will limit i input �rten[ to the slue aced
solared e.com aporp egradelnng inf P/N:SFn refer to: hlpsNQ
9 for power P/N: SEinformationreferto: httpsJM*+wsolaredgemm/sites/defaulVfiles/se-temperatumderaang-note-na.pd!
� -40 version PM: SEwH-USOWNNU4
O Sola,Edge TeWWogiM Inc•ll lights reserved. SOLAREDGEaheSelandge bga OMMMD W SOtAREDGEere ✓ademaka a registe tredemarh orS gl,TerMnbg� IncM
RoMS
Power :Opti maer
For North Am
erc3
P320 / P-340 / P$70 / P.400'/ P405 /,RSQS
W
PV power optimization at the module -level
/ Specifically designed to work with SolarEdge
inverters
/ Up to 25% more energy
Superior efficiency. (99.5%)
/ .Mitigates all types of module mismatch losses,
from manufacturing tolerance to partial
shading
Flexible system design for maximum space
utilization
O
MIT
Fast installation with a.single bolt
/ Next generation maintenance with module -
level monitoring
/ Meets NEC requirements for arc fault
protection (AFCI) and Photovoltaic'Rapid
Shutdown System (PVRSS)
/ Module -level voltage shutdown for installer
and firefighter safety
f Power Optimizer
For North America
P320 / P340 / P370 / P400 / P405 / P505
Rated Input DC Power°
320 1 340
370
400
405
505
W
Absolute Maximum Input
Vohage
Noc at lowest temperature)
48
60
80
1250
83m
Vdc
MPPT Operating Range
8-48
8-60
8-80
12.5-105
12.5-83
Vdc
Maximum Short Cirmft Current
UK)
11
10.1
14
Adc
Maximum DC Input Current
13.75
12.63
17.5
Adc
Maximum Efficiency
99.5
%
Weighted Efficiency
98.8 98.6
%
Civervohage Category
i II
Maximum Allowed System
Voltage
1000
Vdc
Compatible inverters
All SolarEdge Single Phase and Three Phase inverters
Dimensions(W x L x H)
129 x 153 x 27.5/ 5.1 x 6 x 1.1
129 it 153 x 33.5/
5.1 x6x 1.3
129 x 159 x 49.5/
1 5.1 x6.3 x1.9
129 x162 x 59/
5.1 x 6.4x 2.3
mm/in
Weight (inducing cables)
630/1.4
1 75011.7
1 845/1.9
1064/23
gr/Ib
Input Connector
MC40)
Output wire Type / Connector
Double Insulated; MC4
Output wire Length
0.95/3.0 12/3.9
m/ft
Input wire Length
0.16 / 0.52
m / ft
Operating Temperature Range
-40 - .85 /-40 - a185
'C /'F
Protection Rating
IP68 / NEMA6P
Relative Humidity
0 -100
%
o Rater STC power of the module. Module of up to .5%power toleraxe albaed
a NEC 20T7 requires max Input voltage be not more Nan 80V
° For other conrleaer types please comae SolarEdge
Minimum String Length P400 I 8 I 10 18
(Power opt,
iiers) pgp5 / P505 6 8 14
Maximum String Length 25 1 25 1 50'°
Maximum Power per String I SE7600-US - SE11400- 1 5250 1 6000M 1 7750m
--- or Orientations I yes
In For detailed string stagisdormatmn refer m.http%/w xsdamlgewWsireYdefauh/fileygdng-iang-mpdf
° It Is not allowed to mt P405/9505 w1th P320/P340/P370/P400 In one Wing
° A 9mg with more izers than 30 opt does not meet NEC rapid shutdown requvemems; safety voltage will he abom the 30V requirement
° For SEUAl0rS/SE43.2xUS it is allowed to Install up to 6,500W per 9" when 3 Wings are connected to Ore m,arfer (3 strings per unit for SE43.2ws) and when
the maximum power dfterere, between the Wings a up to 1,000Y!
° Far SE30WS/SE333KUS/SE66.6WS/SEt00KU5: It is allowed to in call up to 15,000W per Wing when 3 Wircy are connected to the imener (3 Wings Per unit for SE66.6K1J5/SEI0GKLlS)
and when the maximum power ddremme between the strings is up to 2,000W
w
solaredge-com solar=ee
O Sdarrdge TeTrolma ud.Nlmain rtanaemarla ftim,r he dive4ge lago,GPTPt¢Eeaw6G GNAMa°heett, me wmgi°end Vadem°6 ersderEdge TerhrobpletK
Allatlurtrademab nrenlim�a4 herein ert trWemaM dMde rery¢liroayrwn Oatr.12/2mBAmLFNGlUMSubjed:todunywN°u[mus
CE ROHS
v • •
XR Rail Family
XR Rail Family
Solar is Not Always Sunny
Over their lifetime, solar panels experience countless
extreme weather events. Not just the worst storms in years,
but the worst storms in 40 years. High winds capable of
ripping panels from a roof, and snowfalls weighing
enough to buckle a panel frame. A%
XR Rails are the structural backbone preventing
these results. They resist uplift, protect
against buckling and safely and efficiently t� n
transfer loads into the building structure. ,pd
Their superior spanning capability
requires fewer roof attachments,
reducing the number of roof y.� �-As-,._ r _
penetrations and the amount
of installation time.
Force -Stabilizing Curve
Sloped roofs generate both vertical and lateral
forces on mounting rails which can cause them
to bend and twist. The curved shape of XR Rails
is specially designed to increase strength in both
directions while resisting the twisting. This unique
feature ensures greater security during extreme
weather and a longer system lifetime.
Compatible with Flat & Pitched Roofs
MXRRailsare
IronRidge offers
compatible with ® a range of tilt leg
FlashFoot and options for flat
other pitched roof 'f.l' tl® roof mounting
attachments. applications.
I
Corrosion -Resistant Materials
All XR Rails are made of 6000-series
aluminum alloy, then protected with an
anodized finish. Anodizing prevents surface?
and structural corrosion, while also providing ' P�
a more attractive appearance. -H��=�
The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific
design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match.
x
XR10
XR10 is a sleek, low -profile mounting
rail, designed for regions with light or
no snow. It achieves 6 foot spans, while
remaining light and economical.
• 6'spanningcapability
• Moderate load capability
• Clear & black anodized finish
• Internal splices available
Rail Selection
XR100
XR100 is the ultimate residential
mounting rail. It supports a range of
wind and snow conditions, while also
maximizing spans up to 8 feet
• 8'spanningcapability
• Heavy load capability
• Clear & black anodized finish
• Internal splices available
XR1000
XR1000 is a heavyweight among
solar mounting rails. It's built to handle
extreme climates and spans 12 feet or
more for commercial applications.
12'spanning capability
Extreme load capability
Clear anodized finish
Internal splices available
The following table was prepared in compliance with applicable engineering codes and standards. Values are
based on the following criteria: ASIDE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean
Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications.