Loading...
HomeMy WebLinkAboutREVISION BUILDING PERMITOFFICE USE ONLY: DATE FILED: REVISION FEE: 77 S,j)-7o PERMIT # Y 47 ^ 4,1 — RECEIPT N PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION MO VIKGINIA-AVENUE- FORT PIERCE, FL 34982-5652 SCANNED (772)4.62-,1553 13Y q St. Lucie County APPLICATION. FOR WILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: DETAILED DESCRIPTION OF PROJECT REVISIONS: CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): F OWNER/BUILDER INFORMATION: NAME: g CITY: PHONE STATE: ARCEIFTECT/ENGINEERINFoRmATION: I2G\-kril-3 FAX: ZIP: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: WLCCC 9123109 Id midt%lolh m Revised 06130117 Im RE V N CVFY 1=0011"W BRADEN & BRADEN, A. I. A., P. A. 97rchllecb & of Tanners 417 COCONUT AVENUE, STUART, FLORIDA 34996 TELEPHONE: (772) 2B7-B256 FAX (772) 2B7-B2B3 #AAC-000032 July 2, 2019 St. Lucie County Building Department Permit#:1904-0583 RE: 49 Florida Way To whom it may concern, Please note, The supply duct size from the AHU to the mixing box shall be 14" dia. The return air duct shall be 16" dia. If you have any questions please feel free to call me at (772) 287-8258. Than o , . Braden Braden & Braden AIA PA OFFICE USE ONLY: DATE FILED: PERMIT # REVISION FEE: RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 200 VIRGINIA AVENUE S6ANNM-- FORT PIER,bE, FL 34682-5652 BY (772) 4.62-1553 St. Ucie Coij* APPLICATION FOR, RUILPING PERMIT REVISIONS PROJECT INFORMATION m T LOCATION/SITE ADDRESS: DETAILED DESCRIPTION OF PROJECT REVISIONS: E'GA0 CONTRACTOR INFORMATION: STATE of FL REG./CERT. BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): U STATE: OWNER/BUILDER INFORMATION: NAME: ADDRESS:_ CITY: PHONE(DA ARCHITECT/ENGINEER INFORMATION: ST. LUCIE CO CERT. #: FAX: ZIP: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: SLCCC 9123109 Revised 06130117 v ION R*= NQ BRAOEN & BRAOEN, A. I. A., P. A. 97mbited,5 & 'Planners 417 COCONUT AVENUE, STUART, FLORIOA 34996 TELEPHONE: (772] 287-9259 FAX (772) 267-6263 #AAC-000032 July 2, 2019 St. Lucie County Building Department Permit #:1904-0583 RE: 49 Florida Way To whom it may concern, Please note, the field revisions attached are to the electrical riser and the panel schedule to reflect whats being built in the field. If you have any questions please feel free to call me at (772) 287-8258. � el rraden Braden & Braden AIA PA OFFICE USE ONLY: DATE FILED: -1 REVISION FEE: 1 OG PERMIT #_ S/, (jsh'3 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION -- 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISI01 PROJECT INFORMATION LOCATION/SITE ADDRESS: PEI AUG 06 2019 ST. Lucie County, Permitting FILE COPY SCANNED DETAILED DESCRIPTION OF PROJECT BY REVISIONS: Ls St. Lucie County F.JF QQ rA C�dun/'�.�s CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: ST. LUCIE CO CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): STATE: OWNER/BUILDER INFORMATION: NAME: _ ADDRESS: FAX: CITY: f°SL STATE: fj PHONE(DAYTIME: Zai- 514ey3 FAX: _ ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): STATE: FAX: ZIP: ZIP: 3y9 s Z ZIP: SLCCC: 9123109 REVIE"OON Revised 0616/3011/17 oil Ft III see Project Name: WYNNE THE WINDSOR 49 Builder Name: WYNNE DEVELOPMENT AUG 0 6 20i9 Street: 49 FLORIDA WAY Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. 1904-0683 ST. Lucie County, Permittin Owner: Jurisdiction: 9 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1432.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1753.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1753.00 ft= 6. Conditioned floor area above grade (M 1753 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(151.4 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 245 a. U-Factor: Sgl, U=1.04 111.36 ft2 SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 IF 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1753.0 sgft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.08 PASS Total Baseline Loads: 53.86 1 hereby certify that the plans and specifications covered by Review of the plans and F 11IE S7 gl this calculation are in compliance with the Florida Energy specifications covered by this 0 _ ,_- FOB Code. calculation indicates compliance �O� with the Florida Energy Code. n+n'O%• r f ; '•`` `n PREPA D BY: Before construction is completed r DATES- this building will be inspected for compliance with Section 553.908 21 a I hereby certify that this building, as designed, is in compliance Florida Statutes. Ii, yS with the Florida Energy Code COD WE OWNER/AGEN BUILDING OFFICIAL: DATE: -n� /_1t DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 8/5/2019 8:58 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FC1RM R40Fi-9n17 INPIIT SUMMARY CMFCKI IST RFPQRT PROJECT 'Title: WYNNE THE WINDSOR 49 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 0 Street: 49 FLORIDA WAY Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes - Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft' ___ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC t ft 0 63 ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' ____ 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft' -- 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft' ____ 0 1 0 8/512019 8:58 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ____ 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 It 0 588 ft2 ____ 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN lift 0 209 112 __ 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 It 0 50 ft2 0 1 0 10Slab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 ____ 0 1 0 11Slab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 it 0 169 ft2 -- 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emift Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 112 0 ft2 Light N 0.4 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood _ 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood _ 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood _ 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 S Exterior Concrete Block - Ext WRMSTER BE 4.1 16 0 8 0 128.0 112 0 0 0.3 0 —2 N Exterior Concrete Block - Ext InSdNSTER BE 4.1 7 0 8 0 56.0 112 0 0 0.3 0 —3 E Exterior Concrete Block - Ext IndMSTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 4 S Exterior Concrete Block - Ext IndMSTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 8/5/2019 8:58 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 5 S Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 6 S Exterior Concrete Block - Ext IndI EDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.3 0 7 N Exterior Concrete Block - Ext ImMING/GRE 4.1 30 0 8 0 240.0 ft' 0 0 0.3 0 8 E Exterior Concrete Block - Ext IndAINING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.3 0 9 N Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.3 0 10 S Exterior -Concrete Block- Ext lnsul BATH 4.1 5 0 8 0 40.0 ft' 0 0 -0.3 0 11 W Exterior Concrete Block- Ext Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 12 W Exterior Concrete Block- Ext InsulFOYER 4.1 1 0 8 0 8.0 ft' 0 0 0.3 0 13 S Exterior Concrete Block - Ext InMEDR00M 3 4.1 13 0 8 0 104.0 ft' 0 0 0.3 0 14 N Exterior Concrete Block - Ext InSEDROOM 3 4.1 1 0 8 0 8.0 ft' 0 0 0.3 0 15 W Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft' 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE Insulated FOYER None .32 3 3 6 8 21.7 ft' WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation - Int Shade Screening 1 E 3 Metal Low-E Single Yes 1.04 0.29 N 32.4 ft' 1 ft 0 in 1 It 4 in Drapes/blinds Exterior 5 2 S 5 Metal Low-E Single Yes 1.04 0.29 N 6.9 ft' 1 ft 0 in 1 ft 4 in None None 3 S 6 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft° 1 ft 0 in 1 ft 4 in None None 4 N 7 Metal Low-E Single Yes 1.04 0.29 N 39.8 ft' 1 ft 0 in 1 ft 4 in None None 5 E 8 Metal Low-E Single Yes 1.11 0.27 N 40.0 ft' 8 It 0 in 1 ft 4 in None None 6 S 13 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 805 fN 806 ft' 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .1233 7 8/5/2019 8:58 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Duds 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS --- Supply — — Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 245 ft' Attic 55 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre,Thermostat: Ceiling Fans: Heating ]]Y Jan [XI Feb Mar [ ] [ ] AApr [ jj X� ] May lXl Jun 4 ] Jul f ] Aug [ ] ri Sep [ ] 1J Ocdt [rX'] Nov[[X�] Nov Dec Dec Venting [)Jan l l II 11 Feb X Mar [Xl [ 1 111 11 Jun [ I Jul EX] 1 Aug [ I Sep lxl [X] [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 8/5/2019 8:58 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft' It 0.3 WIC Default(8 Ibs/sq.ft. ft' It 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft' It 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 LAUDRY Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 DINING/GREAT R Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(81bs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 HALL Default(8lbs/sq.ft. ft° ft 0.3 FOYER Default(8 Ibs/s .ft. ft' It 0.3 BEDROOM 3 8/5/2019 8:58 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR 49 Builder Name: WYNNE DEVELOPMENT Street: 49 FLORIDA WAY Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: 1904-0583 Y U Owner: Jurisdiction: w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with /soffit The insulation in an dropped ed ceiling/soffit Y the insulation and any gaps in the air barrier shall be sealed, shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pipino and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrqnkler cover nlates and walls or ceilings a. in aaaalon, inspection of log walls shall be in accordance with the provisions of ICC-400. 8/5/2019 8:58 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12.. Ducts, location-& insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 14. Heating system: Capacity 34.8 c) Area 7c. 151.4 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec0/o B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11C. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Address of New Home: 49 FLORIDA WAY City/FL Zip: FT. PIERCE FL 8/5/2019 8:58:36 AM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1