Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida -Department of Business and Professional Regulation - Residential Performance Method Project Name: E HE GRAN CARLTON IMPACT NE BUILDING OPR Street: �� PermitOffice: STYNUCIE COUNTY SCAIVN� City, State, Zip: FT. PIERCE,, Permit Number: BY Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone pt. Lucie County 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 2 d. N/A R= ftz 5. Is this a worst case? Yes 10. Ceiling Types (1446.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft= 6. Conditioned floor area above grade (ft-) 1446 b. WA R= ft2 Conditioned floor area below grade (ft') 0 c' - 11. Ducts R ft' 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=0.54 101.25 ft' SHGC: SHGC=0.25 b. U-Factor. SgI, U=0.55 40.00 it' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1445.5 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.35 PASS Total Baseline Loads: 48.09 1 hereby certify that the plans and specifications covered by Review of the plans and SAE ST9lR this calculation are in compliance with the Florida Energy specifications covered by this OF Code. calculation indicates compliance y ir; '' _ _ ' •`` with the Florida Energy Code. r. nm g`:.`;•;;'••, "„ O PREPARED B Before construction is completed u DATE: this building will be inspected for 0 „ A compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. WETR� OWNER/fyT��� BUILDING OFFICIAL: DATE: - ` DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: . , WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot# Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 55 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1ft 0 63 ft' _- 0 1 0 3SIab-On-Grade Edge Insulatio M. BATH 8 ft 0 56 ft' 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' _,_ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 511 0 45 ft' _- 0 1 0 6 Slab -On -Grade Edge Insulatio, BEDROOM 2 32.2 ft 0 203.6 ft' _- 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' 0 1 0 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 ____ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ___ 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC / v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft- 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext InS®EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext Infi&DROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext IndIEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext InfiffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block -Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsdtAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext InsSREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext InsQREAT/DINT 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 11/18/2018 1:09 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt' Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 fF WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall V # Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.54 0.25 N 32.9 ft' 1 ft 0 in 1 ft 4 in 0.54 0.25 N 6.9 ft' 1 It 0 in 1 It 4 in 0.54 0.25 N 24.0 ft' 6 It 0 in 1 It 4 in 0.54 0.25 N 37.5 ft' 1 ft 0 in 1 It 4 in 0.55 0.25 N 40.0 ft' 8 It 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 11/1812018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS = Supply — — Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre'Thermostat: CFans: . HeatiDec ng Jan ]]Y Feb Mar Apreiling Apr Mayff May Jun ]] [X] Jul r ]] Aug f[[]] Sep j Irk' L J IrX,] EX] Venting [ ] Jan [ l l 1) Feb X Mar [ IXl Jun [[ ]) Jul [ Aug lXl [ Sep lXl lxl Octet [X] Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 Ibs/sq.ft. ft' It 0.3 M. BATH Default(8 lbs/sq.ft. ft' It 0.3 KITCHEN Default(81bs/sq.ft. ft' It 0.3 BATH Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' It 0.3 ENTRY Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 lbs/s.ft. it' It 0.3 GREAT/DINING Name: Test Rater Rating Compant: Test Rater Date: Li S 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce = c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling /soffit y the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned Spec is. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Pxten behind piping and wo(ing Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, Inspection of log walls shall be In accordance with the provisions of ICC400. 11/1812018 1:09 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location At ic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: ��� Date: �A�1 I q Address of New Home: \�Q `y / ` City/FL Zip: -FT r m,-Fe- > 11/18/2018 1:09:34 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 -- Wrightsoft® Project Summary Entire House QUICK CALCS, INC. Job: Date: By: For. THE GRAND CARLTON WYNNE DEVELOPMKFT. PIERCE, FL SCANNED Notes: \��\� L� St. Luce County Weather. Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none). Humidification 0 Btuh Pi in Btuh Equipment load 23503 Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Area ft He1449 Co 1449 Volume (W) 12511 12511 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 94 48 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 32 OF Backup: 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.049 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 24753 Btuh Latent Cooling Equipment Load Sizing Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req, total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A`030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Air flow factor 0045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 byACCA to meet all requirements of Manual J 8th Ed. Wrightsoft' Right-SuRe® Universal 201717.0.14 RSU08101 2017-Apr-1109:29:38 ACCA - Page 1 ...uick Calcs\DacumentslTl-E GfWJD CARLTON-1446.mp Calc = MJB Gront Door fecee: N - + wrightsoft° RighWID Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LIA, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-4664i796 Email: OUICKCALCS@AOL.COM -1 Room name - Entire House BEDROOM 2 E)osed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heaVcool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft2 297.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2 Load number I (Btuh(ft;`F) (Sh Wft 2) or pedmeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross WP/S Heat Coal Gross I WP/S Heat Cool 6 -13A+1ocs " _ ._..- `D 1, n 400 , .,2,55 503 ':. '465. > 1862 = .-.1184 ':. - ';�72 72 288 - ;.'183 :tA5-2om'" 0770 n,-.>21.56 -19.31. ;38 -. -0. `'815 :_730. 0:-" .:0'... .-.. .: '-0 13A-4ws 0.143 a 4.00 255 128 83 333 212 0 0 .0 0 .. 0 1Aclom 1.270 a 35.56 97.29 24 2 848 2082 0 0 0 0 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W ' ,13A4as 0.143 se -4.0D .265 34 - 34 136 86 0 - 0 0 0 W I--G 13A-0acs 0.143 s 4.00 255 360 353 1414 899 216 216 865 5W 1Ac1cm 1270 s 35.56 34.77 7 7 247 241 0 0 0 0 93AAccs .0 143 w 4,00 2.55 310 237 949 . 6D3 104- 72 M 183 1Ac1om ». .1270 w 35.56 55.21 32 :- 2 -- 1140 1770- 32 ,. -2 . 1140 " 1770 =:0.776 w '.-:.21.56 '19.31 41": 41 =.. 890 -. 788 -`0'- 0 '- 0.. °.:-:0 P 12C-0sw - 0.091 - 2.55 1.28 192 192 489 246 0 0 . - 0 0 C ;:. •., 16A30md. ` _ 0.032 - 0.60 ,: -232 1446 ` 1446 =, 1295 .: •3354 -,297 -297 `_: - 266 *i689 F 22A-tpl .0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED emursion 9181 627 Em Iope loss/gain 14961 13349 4204 40M 12 a) trdiftraticn 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other - 2000 0 Subtotal(lines Etc 13) 17848 175M 5053 4925 Less eternal load 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32°h 49% 5654 8-W 32% 49% 1601 2400 Total room load 235g3 26W 6 Air required(cfm) 1160 1160 326 A&h -IFff- wrightsoft- Right-SufteO Universal 2017 17.0.14 RSUD8101 ...uick CaleatDoeuments\THE GRAND CARLTON-1446.mp Cale = MJ8 Front Door faces: 2017-Apr-11 09:29:38 Page 1 old d mom Z 0 t F 1 wrightsoft° Right-M Worksheet Job: Entire House Date: ' QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-46"796 Email: QUICKCALCS(o)AOL.COM 1 Room name BATH BEDROOM 2 2 E';Med wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heaticool 4 Room dimensions 9.0 x 5.0 It 1.0 x 203.5 ft 5 Room area 45.0 ft' 203.5 ft' Ty Construction U-value Or HTM Area (ft'j Load Area (ft2) Load number I (Btutdit-F) (BtuNfti or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 W LG4AS2om -13A4ocs '�. ;' . 0143 n 4 00 `, ' 2,55 . 40 _ ; 40 160 102 128 -. 128 . > 513 ' 326 :' .0 770 n , ; ..2156 ! ."19.31 ` 0 - - 0 0� ..0 . .0 1. "225 .. . . �/�--G 13A4ocs 0.143 a 4.00 255 0 0 0 0 80 56 - -143 tAclom 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 11 �---D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W .13A4ocs 0.143 se 4.00 255 0 '0 0 0 34 .34 136 '86 U�/ 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 - 81 L-G 1Aclom 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A4acs ' -am w 400 255 0 0 0 .0 0 __ 0 0 -, 0 >IA-clom -.. :�t270 - w :: 3556 , , 55.21 ,0 o -0 .. - o o' o o :.o . 0.770 w . , -21.56 '. 19.31 0 " 0 °.: `- 0 - .0 0-: '0-" 0 '-::0 P 12C41sw _ 0.091 - 265 1.28 0 0 0 0 0 0 0 0 b" 186A30riid_---. .-.f0.032 `:--090--' 232'., .,. q5;. _ -q5- "`40. -. 104'.- '204=_ 204 :: 182 �..-;472 F 22A-tDl 0.969 - 2769 0.00 45 5 138 0 204 34 946 0 61 c)AED excursion -16 _as Envelope loss/gain 339 190 2978 3106 12 a) Infiltration 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 - 0 Subtotal Qines 6 to 13) 425 214 3571 3498 Less e)dww load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 151 Duct loads 32q 49% 135 - 104 320% 490/6 1131 1704 Total roan load Selo; 318 4702 5203 Air required (cfm) 28 14 232 232 �{�r Calculations approved byACCA to meet all requirements of Manual J 8th Ed TFwrightsoft- 2017-Apr-11 09:29:38 -ACZ`h RightSuBe® Universa1.2017 17.0.14 RSU0810t Page 3 ...uick CalcslDocumentslTHE GRAND CARLTOPN446.mp Calc = MJ8 Front Door faces: N F� wrightsoft RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIELN., FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name LAUNDRY GREAVDINING wall eight 6.0 ft 47.0 ft 3 R 8.0 ft heal/cool 9.8 ft heallcool 4 Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 ft 5 Room area 42.0 ft' 526.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (BtulVftMF) (atulJft2) or perimeter (ft) (Btuh). or perimeter (ft) (Btuh) Heat Cool Gloss WP/S Heat Coal Gross WP/S Heat Cool 6 l7t L--G j3A-0ocs ^-. '9laS2am. ..1.0143 n .,.`4.00 255 - ,0 -- 0 _ 0 , - -0 255s 217-.: 869 '.552 :0.770 , n '21.56 19,31 ' 0- 0, 0 :0 '.38'-' 0 :- 815 �y1 13A-0acs 0.143 a 4.00 2-55 0 0 0 0 0 0 0 _.730 0 t---C to-ciom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 1 -D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W - 13AAocs 0.143 as .4.00 255 0 0 0 0 0 0 - 0 0 V}/ I-f 13A-0acs 0.143 s 4,00 265 48 48 192 122 0 0 0 0 1Ac1om 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 3A-4ocs 0143 w 4.00 255 0 0 0 :0 206 165 661 420 1Ac1om .. ..- 1270 • w, 35.56 55.21 0 : - 0 '. 0 - 0 0 - .0 .._ . 0 : . 0 :4A54am'-: ;0770 -w ;-21.56' '-19.31 0. 0-' 10 :..p 41 .:. '41 .e788 P 12C-Osw 0.091 - 2.55 1.28 56 56 143 72 0 ,' 0 .:.. .880 0 0 i6A-30mtl: ,.. 0.032 -:_ : 0.90 :2.32 :' ,.42' 42 `�' '.. 38 -�. -97 526 _ -526 -526 ,;.,. '471 -1220 F 22A-tpl 0.989 - 27.69, 0.00 42 6 166 0 526 47 1302 ,' 0 6 c)AED excursion - -72 668 Envelope lass/gain 539 270 4997 4379 12 a). Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 46D Appliancesiother 0 0 Subtotal Qines 6to 13) 643 298 5994 5112 Lass eMenal load Less transfer 0 0 0 0 Redistnbution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 32% 49% 204 145 32% 49% 1899 2,490 Total room load 846 443 7892 7602 Air recidned(dm) 42 20 390 9% Calculations approved bvACCA to meet all requirements of Manual J 8th Ed - wrightsoR- 2017-Apr-11 09:29:38 RightD CAR Universal .mp Cale 4 RSU081on Page 4 ...uick Calcs\DocumentslTHE GRAND CARLTON4446.mp CaIc=MJB Front Door faces: N wrightsoft RighW@Worksheet Job' Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 7724664i796 Email: QUICKCALCWOLCOM 1 Room name FOYER M. BATH Exposed mhe 7.0ft 8.0 It 3 height 9 8.0 ft heat/cool 8.0 ft heaUcool 4 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft 5 Room area 50.0 ft. 56.0 ft- Ty Construction U-value Or HTM Am (III Load. Area (fly Load number (6tut✓WF) (BtuMft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross I WP/S Heat cool 6 � 1 M46s: ,_ .400 :2;55: .•8 8 -. 32 - -.20. 10: ,.. 0 .,0 `4AS2an- 0770 :0143�•n n .': "2156 ---.19.31 -`0 .. ',0 -. 0 .„ 0' _.,0'. ,0 0 :. 0; >.%„ 0 1 'I 13A4ccs _ 0.143 a 4.00 255 48 27 108 69 0 0 0 0 I--D 1Aclom 1270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W ' .13AAocs 0.143 as 4.00 255 0 0 0 0 0 0 0 0 t--a 13440cs 0.143 s 4.00 255 0 0 0 0 64 57 228 145 1Aclom 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 1344ocs 0.143 w 4.00 255 0 0 0 .0 0 0 0 0 1Acl= .1.270 w 35.56 ... 55.21 0.' 11 0.. .0� -. _.. 0 '..,"0 .`4AS :,... - .0.770. w:': "21.58 .. 19:31 :0. 0• '0' '92 ,0�. 0..... +• P 12C-0sw 0.091 255 1.28 72 72 183 0 0 . , 0 C. 16A I&hd. 0:032' - 0.90 2.32 .50 -50 .: 45 . 116 56, :56. .60 : '..., -130 F 22A4pI 0.989 - 27.69 0.00 50 7 194 0 56 6 222 0 (; c)AM excursion S9 S8 Ernelope loss/gain 792 496 747 478 12 a) Wdtrs0on 121 33 138 38 b) Roomtentilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6to 13) 913 529 885 516 Less eMernalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 629 885 516 15 Duct loads 32% 49% 289 258 32% 49% 280 251 Total room load 1202 787 1166 7 88 Alr required(cfm) 59 35 58 . 34 Calculations approved byACCA to meet all requirements of Manual J 8th Ed 'at' -Fk- wrighttsoft' RIghlSufta® Universal 201717.0.14 RSU08101 2017-Apr-11 09:29:38 ...ulck CaIcslDowmenlslTHE GRAND CARLTON-1446.mp Cale = MJ8 Front Door Faces: N' Page 5 - wrightsoft° Duct System Summary o a: Entire House By: QUICK CALCS, INC. 317 ST. LUC.IE LN., FT. PIERCE, FL 34946 Phone; 772-46M799 Fa,c 772466-6796 Email: QUICKCALCS@AOL.COM ?Lroject Intormation For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (rEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (In) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 0x0 VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 OxO VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 OxO VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 OxO VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 OxO VIFx 31.8 135.0 st2 GREAVDINING-A h 3946 195 169 0.300 7.0 OxO VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 OxO VIFx 17.0 115.0 sti LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115.0 st1 M•BATH-A h 768 58 34 0 0 OxO VIFx 0 0 WIG c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 O:285 918 12.0 0 x 0 VinIFIX st1 st1 Peak AVF 1043 1091 0.285. 1020 14.0 0 x 0 VinIFIX wri htsoft 2017-Apr-1109:29:38 JCC% 9 RightSuite® Universal 2017 17.0.14 RSU08101 Page 1 ...ulck CdcslDocuments%THE GRAND CARLTON-1446.mp Calc = M.18 Front Door faces: N Name Grille Size (in) Htg Clg (Cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (n) StudlJoist Opening (in) Duct Matl Trunk rb1 Ox0 1 1160 1160 0 1 0 0 0 Ox 0 VIFx wrightsoft� RightSuite® Universal 201717.0.14 RSU08101 2017-Apr-11 09:29:38 ...ulck Calcs%Documents%THE GRAND CARLTON-1446.mp Calc = MJ8 Front Door faces: N Page 2