HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida -Department of Business and Professional Regulation - Residential Performance Method
Project Name: E HE GRAN CARLTON IMPACT
NE BUILDING OPR
Street:
��
PermitOffice: STYNUCIE COUNTY
SCAIVN�
City, State, Zip: FT. PIERCE,,
Permit Number:
BY
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone pt. Lucie County
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft'
b. Frame - Wood, Adjacent
R=11.0 192.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 2
d. N/A
R= ftz
5. Is this a worst case? Yes
10. Ceiling Types (1446.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1446.00 ft=
6. Conditioned floor area above grade (ft-) 1446
b. WA
R= ft2
Conditioned floor area below grade (ft') 0
c'
-
11. Ducts
R ft'
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Rat: Attic, AH: Attic
6 250
a. U-Factor: Sgl, U=0.54 101.25 ft'
SHGC: SHGC=0.25
b. U-Factor. SgI, U=0.55 40.00 it'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A ft'
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
8. Floor Types (1445.5 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft'
b. Conservation features
EF: 0.970
b. N/A R= ft'
None
c. N/A R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.35
PASS
Total Baseline Loads: 48.09
1 hereby certify that the plans and specifications covered by
Review of the plans and
SAE ST9lR
this calculation are in compliance with the Florida Energy
specifications covered by this
OF
Code.
calculation indicates compliance
y ir; '' _ _ ' •``
with the Florida Energy Code.
r. nm g`:.`;•;;'••, "„ O
PREPARED B
Before construction is completed
u
DATE:
this building will be inspected for
0 „ A
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
WETR�
OWNER/fyT���
BUILDING OFFICIAL:
DATE: - `
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE COPY
11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: . , WYNNE THE GRAND CARL
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1446
Lot#
Owner Name: WYNNE BUILDING CROP
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR.
Rotate Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
_ /
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1446 11568
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 301
2408 No
0
1
1 Yes
Yes
Yes
2 WIC 63
504 No
0
1 No
Yes
Yes
3 M.BATH 55
448 No
0
1 Yes
Yes
Yes
4 KITCHEN 192
1536 Yes
0
1 No
Yes
Yes
5 BATH 45
360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2 204
1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY 55
440 No
0
1 Yes
Yes
Yes
8 LAUNDRY 42
336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING 488
3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
301 ft'
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1ft 0
63 ft'
_-
0 1
0
3SIab-On-Grade Edge Insulatio
M. BATH 8 ft 0
56 ft'
0 1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft'
_,_
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 511 0
45 ft'
_-
0 1
0
6 Slab -On -Grade Edge Insulatio, BEDROOM 2 32.2 ft 0
203.6 ft'
_-
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft 0
55 ft'
0 1
0
11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY Eft
0
42 ft2
____
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
___
0
1
0
ROOF
/ Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
/
v # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft-
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar
Below
1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
3 NW=>SE Exterior Concrete Block - Ext InS®EDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
6 NE=>SW Exterior Concrete Block - Ext Infi&DROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
7 SE=>NW Exterior Concrete Block - Ext IndIEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
8 S=>N Exterior Concrete Block - Ext InfiffDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
9 SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
10 SE=>NW Exterior Concrete Block -Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
12 SW=>NE Exterior Concrete Block - Ext InsdtAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
13 NE=>SW Exterior Concrete Block - Ext InsSREAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
14 NW=>SE Exterior Concrete Block - Ext InsQREAT/DINT
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
15 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.6
0
11/18/2018 1:09 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DOORS
# Ornt'
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1
6 8
20.6 fF
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall
V # Omt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
0.54 0.25 N 32.9 ft' 1 ft 0 in 1 ft 4 in
0.54 0.25 N 6.9 ft' 1 It 0 in 1 It 4 in
0.54 0.25 N 24.0 ft' 6 It 0 in 1 It 4 in
0.54 0.25 N 37.5 ft' 1 ft 0 in 1 It 4 in
0.55 0.25 N 40.0 ft' 8 It 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315 ft'
315 ft'
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .2578
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubTpe
Location
EF Cap Use SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft'
11/1812018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
DUCTS
= Supply
—
—
Return --
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6
250 ft'
Attic
65 ft'
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programablre'Thermostat:
CFans:
.
HeatiDec
ng Jan
]]Y
Feb
Mar
Apreiling
Apr
Mayff
May
Jun
]]
[X] Jul
r ]]
Aug
f[[]] Sep
j Irk'
L J
IrX,]
EX]
Venting [ ] Jan [
l l
1) Feb
X Mar
[
IXl Jun
[[ ]) Jul
[ Aug
lXl
[ Sep
lXl
lxl Octet [X]
Nov
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft'
0 ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft'
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft'
It
0.3
M. BATH
Default(8 lbs/sq.ft.
ft'
It
0.3
KITCHEN
Default(81bs/sq.ft.
ft'
It
0.3
BATH
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft'
It
0.3
ENTRY
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
Default(8 lbs/s.ft.
it'
It
0.3
GREAT/DINING
Name: Test Rater
Rating Compant: Test Rater
Date: Li S
11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
w
Design Location: FL, Fort Pierce
=
c�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceiling /soffit
y
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned Spec
is.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Pxten behind piping and wo(ing
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, Inspection of log walls shall be In accordance with the provisions of ICC400.
11/1812018 1:09 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location At ic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1446
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.543
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. Builder Signature: ��� Date: �A�1 I q
Address of New Home: \�Q `y / ` City/FL Zip: -FT r m,-Fe- >
11/18/2018 1:09:34 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
-- Wrightsoft® Project Summary
Entire House
QUICK CALCS, INC.
Job:
Date:
By:
For. THE GRAND CARLTON
WYNNE DEVELOPMKFT. PIERCE, FL SCANNED
Notes: \��\� L� St. Luce County
Weather.
Winter Design Conditions
Outside db 42 OF
Inside db 70 OF
Design TD 28 OF
Heating Summary
Structure
17848
Btuh
Ducts
5654
Btuh
Central vent (0 cfm)
0
Btuh
(none).
Humidification
0
Btuh
Pi in
Btuh
Equipment load
23503
Infiltration
Method
Construction quality
Fireplaces
Fort Pierce, FL, US
Simplified
Average
0
Area ft He1449 Co 1449
Volume (W) 12511
12511
Air changes/hour 0.45
0.23
Equiv. AVF (cfm) 94
48
Heating Equipment Summary
Make Carrier
Trade CARRIER AIR CONDITIONING
Model 25HBC536A*030
AHRI ref 7914585
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
Capacity balance point = 32 OF
Backup:
8.5 HSPF
34600
Btuh @ 47°F
27
OF
1160
cfm
0.049
cfm/Btuh
0.50
in H2O
Input = 7 kW, Output = 23009 Btuh, 100 AFUE
Summer Design Conditions
Outside db
90
OF
Inside db
75
OF
Design TD
15
OF
Daily range
Relative humidity
L
50
%
Moisture difference
61
gr/lb
Sensible Cooling Equipment Load Sizing
Structure
17520
Btuh
Ducts
8536
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data n
Rate/swing multiplier 0.95
Equipment sensible load 24753 Btuh
Latent Cooling Equipment Load Sizing
Structure
3203
Btuh
Ducts
2318
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
5521
Btuh
Equipment total load 30274 Btuh
Req, total capacity at 0.70 SHR 2.9 ton
Cooling Equipment Summary
Make
Carrier
Trade
CARRIER AIR CONDITIONING
Cond
25HBC536A`030
Coil
FX4DN(B,F)037
AHRI ref
7914585
Efficiency
12.0 EER, 15 SEER
Sensible cooling
24360
Btuh
Latent cooling
10440
Btuh
Total cooling
34800
Btuh
Actual air flow
1160
cfm
Air flow factor
0045
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.83
byACCA to meet all requirements of Manual J 8th Ed.
Wrightsoft' Right-SuRe® Universal 201717.0.14 RSU08101 2017-Apr-1109:29:38
ACCA - Page 1
...uick Calcs\DacumentslTl-E GfWJD CARLTON-1446.mp Calc = MJB Gront Door fecee: N -
+ wrightsoft° RighWID Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LIA, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-4664i796 Email: OUICKCALCS@AOL.COM
-1
Room name
- Entire House
BEDROOM
2
E)osed wall
156.2 ft
49.0 ft
3
Room height
8.7 ft d
8.0 ft heaVcool
4
Room dimensions
1.0 x 297.0 ft
5
Room area
1445.5 ft2
297.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2
Load
number
I
(Btuh(ft;`F)
(Sh Wft 2)
or pedmeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
I Cool
Gross
WP/S
Heat
Coal
Gross
I WP/S
Heat
Cool
6
-13A+1ocs " _
._..- `D 1,
n
400
, .,2,55
503
':. '465.
> 1862
= .-.1184
':.
- ';�72
72
288
- ;.'183
:tA5-2om'"
0770
n,-.>21.56
-19.31.
;38
-. -0.
`'815
:_730.
0:-"
.:0'...
.-..
.: '-0
13A-4ws
0.143
a
4.00
255
128
83
333
212
0
0
.0
0
..
0
1Aclom
1.270
a
35.56
97.29
24
2
848
2082
0
0
0
0
11
11DO
0.390
a
10.92
11.31
21
21
229
238
0
0
0
0
W '
,13A4as
0.143
se
-4.0D
.265
34
- 34
136
86
0
- 0
0
0
W
I--G
13A-0acs
0.143
s
4.00
255
360
353
1414
899
216
216
865
5W
1Ac1cm
1270
s
35.56
34.77
7
7
247
241
0
0
0
0
93AAccs
.0 143
w
4,00
2.55
310
237
949
. 6D3
104-
72
M
183
1Ac1om ».
.1270
w
35.56
55.21
32
:- 2
-- 1140
1770-
32
,. -2
. 1140
" 1770
=:0.776
w
'.-:.21.56
'19.31
41":
41
=.. 890
-. 788
-`0'-
0
'- 0..
°.:-:0
P
12C-0sw -
0.091
-
2.55
1.28
192
192
489
246
0
0
.
- 0
0
C ;:. •.,
16A30md. ` _
0.032
-
0.60
,: -232
1446
` 1446
=, 1295
.: •3354
-,297
-297
`_: - 266
*i689
F
22A-tpl
.0.989
-
27.69
0.00
1446
156
4325
0
297
49
1357
0
6
c)AED emursion
9181
627
Em Iope loss/gain
14961
13349
4204
40M
12
a) trdiftraticn
2887
791
848
232
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
6
1380
3
690
Appliances/other
-
2000
0
Subtotal(lines Etc 13)
17848
175M
5053
4925
Less eternal load
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
17848
17520
5053
4925
15
Duct loads
32°h
49%
5654
8-W
32%
49%
1601
2400
Total room load
235g3
26W
6
Air required(cfm)
1160
1160
326
A&h -IFff- wrightsoft- Right-SufteO Universal 2017 17.0.14 RSUD8101
...uick CaleatDoeuments\THE GRAND CARLTON-1446.mp Cale = MJ8 Front Door faces:
2017-Apr-11 09:29:38
Page 1
old d
mom
Z
0
t
F 1 wrightsoft° Right-M Worksheet Job:
Entire House Date:
' QUICK CALCS, INC. By:
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-46"796 Email: QUICKCALCS(o)AOL.COM
1
Room name
BATH
BEDROOM 2
2
E';Med wall
5.0 ft
34.2 ft
3
Room height
8.0 ft heat/cool
8.0 ft heaticool
4
Room dimensions
9.0 x 5.0 It
1.0 x 203.5 ft
5
Room area
45.0 ft'
203.5 ft'
Ty
Construction
U-value
Or
HTM
Area (ft'j
Load
Area (ft2)
Load
number
I
(Btutdit-F)
(BtuNfti
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
W
LG4AS2om
-13A4ocs '�.
;' . 0143
n
4 00
`, ' 2,55
. 40
_ ; 40
160
102
128
-. 128
. > 513
' 326
:'
.0 770
n ,
; ..2156
! ."19.31
` 0
- - 0
0�
..0
. .0
1.
"225
.. .
.
�/�--G
13A4ocs
0.143
a
4.00
255
0
0
0
0
80
56
-
-143
tAclom
1.270
a
35.56
87.29
0
0
0
0
24
2
848
2082
11
�---D
11DO
0.390
a
10.92
11.31
0
0
0
0
0
0
0
0
W
.13A4ocs
0.143
se
4.00
255
0
'0
0
0
34
.34
136
'86
U�/
13A4ocs
0.143
s
4.00
2.55
0
0
0
0
32
32
128
- 81
L-G
1Aclom
1270
s
3556
34.77
0
0
0
0
0
0
0
0
13A4acs '
-am
w
400
255
0
0
0
.0
0
__ 0
0
-, 0
>IA-clom -..
:�t270
- w
:: 3556
, , 55.21
,0
o
-0
.. - o
o'
o
o
:.o
.
0.770
w
. , -21.56
'. 19.31
0
" 0
°.: `- 0
- .0
0-:
'0-"
0
'-::0
P
12C41sw _
0.091
-
265
1.28
0
0
0
0
0
0
0
0
b" 186A30riid_---.
.-.f0.032
`:--090--'
232'.,
.,. q5;.
_ -q5-
"`40.
-. 104'.-
'204=_
204
:: 182
�..-;472
F
22A-tDl
0.969
-
2769
0.00
45
5
138
0
204
34
946
0
61
c)AED excursion
-16
_as
Envelope loss/gain
339
190
2978
3106
12
a) Infiltration
87
24
593
162
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
1
230
Appliances/other
0
- 0
Subtotal Qines 6 to 13)
425
214
3571
3498
Less e)dww load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
425
214
3571
3498
151
Duct loads
32q
49%
135
- 104
320%
490/6
1131
1704
Total roan load
Selo;
318
4702
5203
Air required (cfm)
28
14
232
232
�{�r Calculations approved byACCA to meet all requirements of Manual J 8th Ed
TFwrightsoft- 2017-Apr-11 09:29:38
-ACZ`h RightSuBe® Universa1.2017 17.0.14 RSU0810t Page 3
...uick CalcslDocumentslTHE GRAND CARLTOPN446.mp Calc = MJ8 Front Door faces: N
F� wrightsoft RighW@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIELN., FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772466-6796 Email: QUICKCALCS@,AOL.COM
1
Room name
LAUNDRY
GREAVDINING
wall
eight
6.0 ft
47.0 ft
3
R
8.0 ft heal/cool
9.8 ft heallcool
4
Room dimensions
7.0 x 6.0 ft
1.0 x 526.0 ft
5
Room area
42.0 ft'
526.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(BtulVftMF)
(atulJft2)
or perimeter (ft)
(Btuh).
or perimeter (ft)
(Btuh)
Heat
Cool
Gloss
WP/S
Heat
Coal
Gross
WP/S
Heat
Cool
6
l7t
L--G
j3A-0ocs ^-.
'9laS2am.
..1.0143
n
.,.`4.00
255
- ,0
-- 0
_ 0
, - -0
255s
217-.:
869
'.552
:0.770
, n
'21.56
19,31
' 0-
0,
0
:0
'.38'-'
0
:- 815
�y1
13A-0acs
0.143
a
4.00
2-55
0
0
0
0
0
0
0
_.730
0
t---C
to-ciom
1.270
a
35.56
87.29
0
0
0
0
0
0
0
0
1
-D
11DO
0.390
a
10.92
11.31
0
0
0
0
0
0
0
0
W -
13AAocs
0.143
as
.4.00
255
0
0
0
0
0
0
- 0
0
V}/
I-f
13A-0acs
0.143
s
4,00
265
48
48
192
122
0
0
0
0
1Ac1om
1270
s
35.56
34.77
0
0
0
0
0
0
0
0
3A-4ocs
0143
w
4.00
255
0
0
0
:0
206
165
661
420
1Ac1om .. ..-
1270
• w,
35.56
55.21
0
: - 0
'. 0
- 0
0
- .0
.._ . 0
: . 0
:4A54am'-:
;0770
-w
;-21.56'
'-19.31
0.
0-'
10
:..p
41
.:. '41
.e788
P
12C-Osw
0.091
-
2.55
1.28
56
56
143
72
0
,'
0
.:.. .880
0
0
i6A-30mtl:
,.. 0.032
-:_
: 0.90
:2.32
:' ,.42'
42
`�' '.. 38
-�. -97
526
_
-526 -526
,;.,. '471
-1220
F
22A-tpl
0.989
-
27.69,
0.00
42
6
166
0
526
47
1302
,'
0
6
c)AED excursion
- -72
668
Envelope lass/gain
539
270
4997
4379
12
a). Infiltration
104
28
997
273
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
2
46D
Appliancesiother
0
0
Subtotal Qines 6to 13)
643
298
5994
5112
Lass eMenal load
Less transfer
0
0
0
0
Redistnbution
0
0
0
0
14
Subtotal
643
298
5994
5112
15
Duct loads
32%
49%
204
145
32%
49%
1899
2,490
Total room load
846
443
7892
7602
Air recidned(dm)
42
20
390
9%
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
- wrightsoR- 2017-Apr-11 09:29:38
RightD CAR Universal .mp Cale 4 RSU081on Page 4
...uick Calcs\DocumentslTHE GRAND CARLTON4446.mp CaIc=MJB Front Door faces: N
wrightsoft RighW@Worksheet Job'
Entire House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 7724664i796 Email: QUICKCALCWOLCOM
1
Room name
FOYER
M. BATH
Exposed
mhe
7.0ft
8.0 It
3
height
9
8.0 ft heat/cool
8.0 ft heaUcool
4
Room dimensions
1.0 x 50.0 ft
7.0 x 8.0 ft
5
Room area
50.0 ft.
56.0 ft-
Ty
Construction
U-value
Or
HTM
Am (III
Load.
Area (fly
Load
number
(6tut✓WF)
(BtuMft')
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Gross
I WP/S
Heat
cool
6
�
1 M46s: ,_
.400
:2;55:
.•8
8
-. 32
- -.20.
10:
,.. 0
.,0
`4AS2an-
0770
:0143�•n
n
.': "2156
---.19.31
-`0
.. ',0
-. 0
.„ 0'
_.,0'.
,0
0
:. 0;
>.%„ 0
1
'I
13A4ccs _
0.143
a
4.00
255
48
27
108
69
0
0
0
0
I--D
1Aclom
1270
a
35.56
87.29
0
0
0
0
0
0
0
0
11
11DO
0.390
a
10.92
11.31
21
21
229
238
0
0
0
0
W '
.13AAocs
0.143
as
4.00
255
0
0
0
0
0
0
0
0
t--a
13440cs
0.143
s
4.00
255
0
0
0
0
64
57
228
145
1Aclom
1.270
s
35.56
34.77
0
0
0
0
7
7
247
241
1344ocs
0.143
w
4.00
255
0
0
0
.0
0
0
0
0
1Acl=
.1.270
w
35.56
... 55.21
0.'
11
0..
.0�
-. _.. 0
'..,"0
.`4AS
:,... -
.0.770.
w:':
"21.58
.. 19:31
:0.
0•
'0'
'92
,0�.
0.....
+•
P
12C-0sw
0.091
255
1.28
72
72
183
0
0
. ,
0
C.
16A I&hd.
0:032'
-
0.90
2.32
.50
-50
.: 45
. 116
56,
:56.
.60
: '..., -130
F
22A4pI
0.989
-
27.69
0.00
50
7
194
0
56
6
222
0
(;
c)AM excursion
S9
S8
Ernelope loss/gain
792
496
747
478
12
a) Wdtrs0on
121
33
138
38
b) Roomtentilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal pines 6to 13)
913
529
885
516
Less eMernalload
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
913
629
885
516
15
Duct loads
32%
49%
289
258
32%
49%
280
251
Total room load
1202
787
1166
7 88
Alr required(cfm)
59
35
58
. 34
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
'at' -Fk- wrighttsoft' RIghlSufta® Universal 201717.0.14 RSU08101 2017-Apr-11 09:29:38
...ulck CaIcslDowmenlslTHE GRAND CARLTON-1446.mp Cale = MJ8 Front Door Faces: N'
Page 5
- wrightsoft° Duct System Summary o a:
Entire House By:
QUICK CALCS, INC.
317 ST. LUC.IE LN., FT. PIERCE, FL 34946 Phone; 772-46M799 Fa,c 772466-6796 Email: QUICKCALCS@AOL.COM
?Lroject Intormation
For. THE GRAND CARLTON
WYNNE DEVELOPMENT, FT. PIERCE, FL
Extemal static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (rEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.285
in/100ft
1160
cfm
176
Cooling
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.285
in/100ft
1160
cfm
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(In)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h 560
28
14
0.364
4.0
0x0
VIFx
22.4
115.0
st1
BEDROOM 2
h 4702
232
232
0.360
7.0
OxO
VIFx
23.9
115.0
st1
BEDROOM -A
h 3327
164
163
0.300
6.0
OxO
VIFx
31.8
135.0
st2
BEDROOM-B
h 3327
164
163
0.285
6.0
Ox0
VIFx
40.6
135.0
st2
FOYER
h 1202
59
35
0.505
4.0
OxO
VIFx
4.0
95.0
GREAT/DINING
h 3946
195
169
0.300
7.0
OxO
VIFx
31.8
135.0
st2
GREAVDINING-A
h 3946
195
169
0.300
7.0
OxO
VIFx
31.8
135.0
st2
KITCHEN
c 3437
21
153
0.379
6.0
OxO
VIFx
17.0
115.0
sti
LAUNDRY
h 846
42
20
0.361
4.0
OxO
VIFx
23.3
115.0
st1
M•BATH-A
h 768
58
34
0
0
OxO
VIFx
0
0
WIG
c 174
3
8
0.309
4.0
Ox0
VIFx
27.0
135.0
st2
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FIR
(fpm)
(in)
(in)
Material
Trunk
st2
Peak AVF
721
672
O:285
918
12.0
0 x 0
VinIFIX
st1
st1
Peak AVF
1043
1091
0.285.
1020
14.0
0 x 0
VinIFIX
wri htsoft 2017-Apr-1109:29:38
JCC% 9 RightSuite® Universal 2017 17.0.14 RSU08101 Page 1
...ulck CdcslDocuments%THE GRAND CARLTON-1446.mp Calc = M.18 Front Door faces: N
Name
Grille
Size (in)
Htg
Clg
(Cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(n)
StudlJoist
Opening (in)
Duct
Matl
Trunk
rb1
Ox0
1 1160
1160
0
1 0
0
0
Ox 0
VIFx
wrightsoft� RightSuite® Universal 201717.0.14 RSU08101 2017-Apr-11 09:29:38
...ulck Calcs%Documents%THE GRAND CARLTON-1446.mp Calc = MJ8 Front Door faces: N Page 2