Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE,�Ii E GRAND CARLTON [W-6CT Builder Name: WYNNE BUILDING COPR. Street: \..l'S lftM1,�j2\ U Permit Office: ST. LUCIE COUNTY �+f'+qp� SCANNED City, State, Zip: FT. PIERCE, FL, Permit Number: BY Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Cie St Lucje.Cou .Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2) „`y 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1446.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade (ft� 1446 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor. Sgl, U=0.54 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.55 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1445.5 sgft.) Insulation Area EF: 0.970. a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.35 PASS Total Baseline Loads: 48.09 1 hereby certify that the plans and specifications covered by Review of the plans and f tVJE STgl this calculation are in compliance with the Florida Energy specifications covered by this ♦•� Code. - calculation indicates compliance with the Florida Energy Code. F uu,••:, •`.,+; r••.•• , PREPAREDBBefore construction is completed r DATE: this building will be inspected for compliance with Section 553.908 a° I hereby certify that this building, as designed, is in compliance Florida Statutes. Jt with the Florida Energy Code. COb WE SRC OWNER//\�EN �^ BUILDING OFFICIAL: DATE: ``--lt `1 ` DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE C®F� 11118/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT • Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, *New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' _- 0 1 0 " 2Slab-On-Grade Edge Insulatio WIC 1 ft 0 63ft' ___ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' _- 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' _- 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' ___ 0 1 0 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ___ 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ftz Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301112 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood _ 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Space Cavity Width RA/glue Ft In Height Et In Arm Sheathing Framing RA/mIrip Frpe!tmnn Solar Ahqnr Below rrnfJP9A 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 6• NE=>SW Exterior Concrete Block - Ext Ind3EDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext InREDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext Indi&DROOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext IndZffDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block -Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsdU1UNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N=>S Garage Frame -Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 11/18/2018 1:09 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall V # Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 0.54 0.25 N 32.9 ft' 1 ft 0 in 1 ft 4 in 0.54 0.25 N 6.9 ft' 1 ft 0 in 1 ft 4 in 0.54 0.25 N 24.0 ft' 6 ft 0 in 1 ft 4 in 0.54 0.25 N 37.6 ft' 1 ft 0 in 1 ft 4 in 0.55 0.25 N 40.0 ft' 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter. Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft aft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Duds 1 Electric Heat Pump/ Split HSPF:8.5- 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfrn 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS / — Supply -- -- Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Ceiling Fans:Coolln Jan '�Y FebrDO� Vent Jan Feb Mar May �X� Jun Jul �X� upr �x� r[ r[ Oct[X]] OctOcctt Nov Dec [[X]] ng [ ] [X] A May Jun Jul Aug [x� Sep [X� [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 It 0.3 BEDROOM Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 Ibs/sq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 Ibs/sq.ft. ft' ft -0.3 BEDROOM 2 Default(81bs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft' ft 0.3 LAUNDRY Default 81bs/s .ft. ft' It 0.3 GREAT/DINING Name: Test Rater Rating Compant: Test Rater D. L 11/18/2018 1:09 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the cmwlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninono and wirina. Shower/tub The air barrier installed at extedor walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricalfphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilinas a. In aaamon, Inspection of log walls shall be in accordance with the provisions of [CC-400. 11/18/2018 1:09 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: � -- Date: Address of New Home\AS Q-C�'h..t z, ``'\Q5 City/FL Zip: -F�� `- i 3N1s5�Z\ 11/18/2018 1:09:30 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 wrightsoft° Project Summary oo , Entire House By: QUICK CALCS, INC. For. THE GRAND CARLTON SCANNED WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: ( `'\S � —"�Q \- '- p St. Lucie, county Design Information Weather. Winter Design Conditions Outside db 42 OF Inside db 70OF Design TD 28 OF Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none). Humidification 0 Btuh Piping 0 Btuh Equipment -load 23503 Btuh Fort Pierce, FL, US Infiltration - Method Simplified Construction quality Average Fireplaces 0 Area ft m Head cool, rZ Volume W) ( 1251661 12516 1 Airchangeslhour 0.45 0.23 Equiv. AVF (cfm) 94 48 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Airflow factor Static pressure Space thermostat Capacity balance point = 32 OF 8.5 HSPF 34600 Btuh @ 47°F 1160 cfm 0.049 cfm/Btuh 0.50 in H2O Backup: Input = 7 kW, Output = 23009-Btuh, 100 AFUE Summer Design Conditions Outside rib 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Ratelswing multiplier Equipment load 0.95 sensible 24753 Btuh Latent Cooling Equipment Load Sizing Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh (none). Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req, total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360. Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual -airflow 1160 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed .. + wrightsoft- RightSuhe® Universal 201717.0.14 RSU08101 2017-Apr-11 09:29:38 ACCA Page 1 ...uiek Calcs%Documentsl7F♦E GRAND CARLTOW"limp Cale - MJ8 Front Door faces: N wriotsoft Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE Lh1, FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name Emine House BEDROOM 2 Elposed wall 156.2 ft 49.0 ft 3 Room height 8.7 it d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room ana 1445.5 ft' 297.0 ft' Ty Construction U-value Or HTM Area (ft) Load Area (ftj Load number (Btuhtft;°F) (Btuwfti or perimeter (ft) (Btuh) a perimeter (ft) (Btuh) . Heat I Coal Gross WPIS Heat Cool Gross WPIS Heat Cool 8 Vy ..13A-0ocsr.-,. -,0.143 ,.rn .... 4.00 :255' 503.> 455 , .,,_4862 's: 11B4 }72 � 288 183 �G 4AS20m : " 0.770 . h . ` 21.56 , '49.31 . 38 - 0 862 : 730 - 0 , .. 01. .0 -0 W , 13A-0acs 0.143 a 400 2.55 128 83 333 212 0 0 0 0 1Ac1cm 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 I�---GD 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W - " .13A-4= 0:143 as • 4.00 255 34 - 34 136 86 0 0 -0 0 tR/ L--� 13A4acs 0.143 s 4.00 255 360 353 1414 899 216 216 - 865 550 1Aclom 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 13A4ecs 0.143 w - 4.00 2.65 310 237 949 . 603 104 -'n 288 183 1Aclom, 1270 w - 35.66 65,21 -32 .._. 2 .1140 1770 .32. •2 1140 4A5-2an _,, ':0.T70 ..w .-:. 21.56 '19!31 41, 41 !. 880, 788 ..00, .; .. 0:.0 .+..4770 P 12C41sw 0.091 2.55 1.28 192 192 489 246 0 0 0 0 ,C', .,116A-30nd - 0.032 - . .0.90 232 1446-: -,1446.. 1295 :. 3354.: ..:297 297':.. -.'266 '- ,. 689 F _ 22A4p1 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED exurslon 918 627 FJnelope lassIgain 14961 13349 421341 4D03 12 a). Infli8ra w 2887 791 848 232 b) Roomventilation 0 0 0 0 13 Intemal gains: Occupants @ 23D 6 1380 3 690 Appllanceslother 2000 0 Subtotal 0[nes 6to 13) 17848 17520 5053 4925 Less aderel load 0 0 0 0 Less.twe" r 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% 5654 &%6 32% 49% 1601 2400 Total room toed 23503 26056 6658 7325 Air required (ofm) 1160 116D 328 326 L`A -Frf- wrightsofv RightSuBe® Universal 201717.0.14 RSU08101 ... uick Calcs\Documents\THE GRAND CARLTON-1446.mp Calc = MJS Fmnt Door faces: 2017-Apr•11 09:29:38 Page 1 wrightsoft° Right-JO Worksheet Job: Entire House Dy:e: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Emil: OUICKCALCS@AOL.COM 1 Roomname WIC KRCHEN 2 .E)gmed wail 0 It 0 It 3 Room height 8.0 ft healfcool &0 It heWcool 4 Room dimensions 6.0 x 9.0 It 1.0 x 1720 1t 5 Room area 54.0 ft- 1720 ft' Ty Construction U-value Or HTM Area Load AM 2) Load number (BtuWftk F) (Btuh/ft2) or perimeter (ft) (BM) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Ccol Gnus WP/S Heat Cool 6 '.73A-0acs <::,.., 0.143 .-6- .'4.00 2.55 -;0 - 0. 0-.. 0 ,0' 0 0' 0 4A5-tom + . ' '0.770 r n` '21.56 19i37 , 0'' 0 --- 0. - .0 0' �,:.:' :0 : ',0 . V/I 13AAM 0.143 a 4.00 2.55 0 .0 0 0 0 .0 0 0 0 �L-ID; 1Ac1cm 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11D0 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 ,W : - 13A-4= 0.143 se 4.00 255 0 0 0 - 0 0 0 ' 0 0 W I--G 13A4= 0.143 s 4.00 255 0 0 0 0 0 0 0 0 1Asiom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 W 13AAocs "' .0.143 w 4.00 .2.55 0 0 0 .0 0 0- 0 0 �--G -1Aclom 1.270 w 35.56 55.21 0 0 0 0 0 0 0 - 0 �--G 4A5-20m -: .0.770 - w. 21.56 19.31 0 , 0 . 0 0 0 . - :0:", 0 ' 0 P.. .12Cb)sw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82 C-i'116A30md-:', '0:032 <- .''.0.90 '.� 232 ° `.64,t. 54 48. -. 125:,_ .172' .-172 .154 ,.,',399 F 22Mtpl 0.989 - 27.69 0.00 54 0 0 0 172 0 0 0 6 c) AEO excurslon -9 -170 Envelope loss/gain 48 117 317 311 12 a) trrf9tration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal Qires 6 to 13) 48 117 317 2311 Less e#emal load 0 0 0 0 Less transfer 0 0 0 Redistribution 0 0 0 .0 14 Subtotal 48 117 317 2311 15 Duct loads 32% 49% 15 57 32% 49% 0 100 1126 Total room load 64 174 418 Air required(cfm) 3 8 21 T7 153 wrightsOftjerA RightSuiteO Universal 201717.0.14 RSU08101 ...uick CalaWocuments\THE GRAND CARLTONL1446.mp Calc = MJ8 Front 0car faces: 2017-Apr-11 09:29:38 Page 2 wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-4665799 Fax 772-46M796 Emil: g01CKCALCS@AOLCOM 1 Room name BATH BEDROOM 2 2 Exposed wall 5.0 It 34.2 ft 3 Room height 8.0 ft heat/cod 8.0 If heatfccol 4 Room dimensions 9.0 x 6.0 If 1.0 x 203.5 It 5 Room area 46.0 ft- 203.5 ft Ty Construction U-value Or HTM Area (ft� Load Area (ft5 Load number (BtuWfti°F) @1 W O or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 -4AS2om- .13A-0ocs- } - 0143 , n. 4.00 : '-2.55 , 40 - • 40 160 > 102 128 - `-:128: 513 ',: 328 ', .0770: n- ...21.56` 19'31 .Ol- •0 0 '. .0' - '0' 0: '- 0:.: " 0 4�/�-G 13A-0ocs 0.143 a 4.00 2.55 0 0 0 0 80 . 56 225 143 1Aclom 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 11 I-D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 w .13AAccs- 0.143 se 4,00 255 0 0 0.- 0 34 .34 136 86 W 13A4ocs 0.143 s 4.00 255 0 0 0 0 32 32 128 81 Y-C 1Ac1an 1270 s 3556 34.77 0 0 0 0 0 0 0 0 ' '13A4ocs 0.143* w 400 2.55; 0 0 0 0 0 0. 0 0 lAolom:... . : 1.27o w .. ,3566 ....55.21 - .0 0 0- .. 0: 0 r - -0 `. 0 .. ID . ;4AS2orim . _ ".0.770 - w • ' '21.56 19.31 - 0 0 0 • .0 0 . ' 0 : .. 0 .. - •.. 0 P 12C41sw 0.091 255 1.28 0 0 0 0 0 0 0 0 C ,';'lao, O d- - - 0.032 - , :0.9D ` 232 - 45, 45 ' 40 104 204 204. =-182 -: .- 472 F 22A4PI 0.989 - 27.69 0.00 45 5 138. 0. 204 34 946 .. - 0 6 c)AED excursion -16 -85 Emrvelope loss/gain 339 190 2978 3106 12 a) infiltration 87 24 593 162 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants @ MO 0 0 1 230 Appfianceslother 0 0 Subtotal Omer 6 to 13) 425 214 3571 3498 Less exdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Duct loads 32°( 49% 135 104 32% 49% 1131 1704 Total room load 560 318 4702 6203 Airrequired(det) 28 14 232 232 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed h 414- wrightsoft RlghtSuite48 Universal 201717.0.14 RSU08101 2017-Apr-11 09:age 3 ...uick CalaskDocuments%THE GRAND CARLTON-1448.mp Cate = MJ8 Front Door faces: N Page 3 wrightsoftRighW@ Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LPL, FT. PIERCE, FL 34946 Phone: 772-46"799 Fax 772-06(W96 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DINWG 2 E)gmed wall 6.0 It 47.0 ft 3 Room height 8.0 It heat/cool 9.8 It heat/cool 4 Room dimensions 7.0 x 6.0 It 1.0 x 526.0 ft 5 Room area 42.0 ft2 526.0 ft2 Ty Construction U-xdue Or HTM Area (ft2) Load Prey (ft2) Load number (Btuh/ft-F) (Bluh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross WP/S Heat Cool Gross WP/S Heat Cod 6 '13A-4ccs,-... •. ."0143 , n`� `. .1400 ',." 2.55 0 _._. 0 ' - 0.'. .:0 255 • 217 •... .• 869 '.. ,552 I-4;. 4A5-tam...-.. ` .0.770 n 21 56. 19,31 ' ., 0 --�0.. 0 - :0 - :-38 '= `D 815 . r 730 lj 13A4= 0.143 a 4.00 255 0 0 0 0 0 0 0 .., 0 �f �D 1Aclon 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W. -13A4acs 0.143 se 4.00 255 0 0 0 0 0 0 .0 0 ly �--G 13A-4ors 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 1Acicm 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-4= 0143 w 4.00 255 0 0 0 0 206 165 661 420 1Aacicrn . 1270 w 35.56 , 55.21 -0 - 0 0 0 -. 0 '0 !.' 0 .. 0 '4f5-2orn, ',0.770 w' ? '.21.56 • 19.31 - `0 ,.0 .:; 0 ' " .0 41 41 ` 680 ' : ".:788 P 12C4xsw 0.091 255 1.28 56 56 143 72 0 0 0 0 .C, '- - s16A-30rnd' ." ' 0.032 - - ;0.90 , 2.32 - 42 . 42 ' 38 _ - .. ' 97 526 .. 526 . , .'47,1 :..:1220 F 22htpl 0.989 27.69 0.00 42 6 166 0 526 47 1302 0 6 c)AED excursion -22 668 Envelope lass/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (fines 6 to 13) 643 298 5994 5112 Less exdeunal load 0 0 -C 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 32% 49% 204 145 32% 49% 1899 249 0 Total room load 846 443 7892 7602 Air required (cfm) 42 20 390 338 �A -FP- wrightsofC RlghtSuftelb Universal 2017 17.0.14 RSU08101 ...uick CalcslDocum Ints%THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: 2017-Apr-11 09:29:38 Page 4 wrightsoft RighW@ Worksheet e: Entire House Date: QUICK CALCS, INC. 317 ST. LUCIE LK, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Emil: OUICKCALCS@ADL.COM 1 Room name FOYER M. BATH EVwedheight 7.0 ft 8.0 ft 3 Room 8.0 ft heaVcOd 8.0 ft heat/cool 4 " Roomdmensicns 1.0 x 50.0 It 7.0 x 8.0 ft 5 Room area 60.0 ft' 56.0 ft Ty CORSInIctim U-value Or HTM Area Load Am (ftj Load number (BWWWF) (Muhl(tm or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross WPIS Heat Cool Gross WP/S Heat Cod 6 ''4A5-2om� '113AAocz i-:-0143n -" ; . 400 -.. 2;55 •48 '0 `- -8 32. - 20 0 °, - -0:-. 0 =.-.0 :0.770 n':.'2156 ,19.31 ...: - .,0 .. 0 - -..„ 0 .. 0-. .,.0- .. 0 .,0 4�--G 13A-0ocs 0.143 a 4.00 255 48 27 108 69 0 0 0 0 1Ac11orn 1270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 I--D 1100 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W - .13A4acs 0.143 se 4.00 255 0 0 0 . 0 0 " 0 .0 - 0 W 13 4-0 0.143 s 4.00 255 0 0 0 0 64 57 228 145 1Aclom 1270 s 35.56 34.77 0 0 0 0 7 7 247 241 13A4= 0.143 w 4.00 255 0 0 0 0 0 0 0 0 _ �.1Ac1om- ,. 1.270 w. 35.66 < 55.21 0, - 0 0 0 _ 0. 0 `:... 0 ...:0 4AS-26(n-:, 0.770 .w. '21.56 '. 19.31 ` -0 0. - 0 c -0 - -- 0 - `0 ` 0 -: '- 0 P 12C-0,sw 0.091 - 255 1.28 72 72 183 92 00 00 C ; )16A - - 0.032 "- ' .0.90 2.32 : 50. � 50 ; ' 45 . .116 '56 '- . 56 ,50 -. 130 F tpl 22A-tpl 0.989 - 27.69 0.00 50 7 194 0 56 8 222 0 6 c)AED excursion gq S8 Envelope loss/gan 792 496 747 478 12 a)Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gars: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal Qines 6 to 13) 913 529 885 616 Less Warne] load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 629 885 516 15 Duct loads 32-A 49% 289 258 32/. 49% 280 251 Total room load 1202 787 1166 768 r reured(cfm) 35 58. .4&' -"*- wrighttsoft• R19htSufte® Unkmal 201717.0.14 RSU08101 ...ulck Calcs%DocumentslTHE GRAND CARLTON-1446.mp Calc = MJ8 Front Door faces: 2017-Apr-11 09:29:38 Page 5 Duct System SummaryJob: wll•ightsof't Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LPL, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: OIBCKCALCS@AOL.COM r-'roject Intormation For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (In) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 660 28 14 0.364 4.0 OxO VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 OxO VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 OxO VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 OxO VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 OxO VIFx 4.0 95.0 GREAVDINING h 3946 1951 169 0.300 7.0 OxO VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115.0 st1 M. BATKA h 768 58 34 0 0 OxO VIFx 0 0 wlc c 174 3 8 0.309 4.0 OxO VIFx 27.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FIR (fpm) (in) pn) Material Trunk .st2 Peak AVF 721 . 672 0:285 918 12.0 0 x 0 VinlFix st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFix ti wri htsoft• 2017-Apr-1109:29:38 � - 9 Right-Suile® Universal 2017 17.0.14 RSU08101 Page 1 ...uick Calos0ocumntsITHE GRAND CARLTOP:1446.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (n) Stud/Joist Opening (in) Duct Matl Trunk rb1 I Ox0 1 1160 1160 0 1 0 0 0 Ox 0 VIFx 2017-Apr-11 09:29:38 wrightsoft RightSuiteO Universal 201717.0.14 RSUGS101 Page 2 ...ulck Calcs\Documents\7HE GRAND CARLTON-1446.mp Cale = MJ8 Front Door faces: N