Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: NNE THE GRAND CARLzON MPACT CC Builder Name: WYNNE BUILDING COPR. W!'1�NNE SW!'1prNG® Street: Cam- ` Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: BY Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 1260.00 ft' b. Frame - Wood, Adjacent R=11.0 192.00 ft' 3. Number of units, if multiple family 1 c. NIA R= ft' 4. Number of Bedrooms 2 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1446.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft' 6. Conditioned floor area above grade (ft') 1446 b. N/A R= ft° Conditioned floor area below grade (W) 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(141.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=0.54 101.25 ft' SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.55 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1445.5 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.35 PASS Total Baseline Loads: 48.09 1 hereby certify that the plans and specifications covered by Review of the plans and ST4l� this calculation are in compliance with the Florida Energy specifications covered by this 0448E 1 _ ; O� Code. calculation indicates compliance a ` ' e:' .0 with the Florida Energy Code. y� „ nu„_ ' ,',::r •;;'. °, �O PREPARED BY: Before construction is completed r DATE: - - this building will be inspected forI�- compliance with Section 553.908 y I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COp WE OWNER/AGEN - '1 BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 - 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' — 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 fP -- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' — 0 1 0 4SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' _- 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' _—_ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 It 0 203.5 ft' _-__ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' _- 0 1 0 11/1812018 1:09 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY E ft 0 42 W ---- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 It' _--- 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 112 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREATIDINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 11:2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext Ins®EDROOM 4.1 28 0 8 0 224.0 11:2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 112 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext InJIEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext Ind]ffDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext IndIEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext Ind]&DROOM 2 4.1 2 0 8 0 16.0 112 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsdIAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block -Ext InsGREAT/DINT 4.1 26 0 8 0 208.011:2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext Ins2REAT/DINT 4.1 20 0 8 0 160.0 11:2 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal _ 2 SW=>NE 4 Metal _ 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.54 0.25 N 32.9 ft' 1 It 0 in 1 ft 4 in 0.54 0.25 N 6.9 ft' 1 It 0 in 1 ft 4 in 0.54 0.25 N 24.0 ft' 6 It 0 in 1 ft 4 in 0.54 0.25 N 37.5 ft' 1 It 0 in 1 ft 4 in 0.55 0.25 N 40.0 ft' 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA Egl-A ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr elm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 250 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablre Thermostarxt:']Y Ceiling Fans: Cooling [X� Jan Feb [[ ]] fX] Mar [ ] L J APr May Jun [[ [X� JuI rr ]] [X] Aug [ ] Sep �jj rD('I L.l Oct Nov Nov r[X,] Dec Dec Venting III[ III Jan [ 1 Feb L 1 IIX1l Mar lxl lXl Jun [[ Jul [[ 11 Aug EX] ] Sep ll�xll [X] [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft' 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft' It 0.3 WIC Default(8 Ibs/sq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft, ft 0.3 BATH Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft, ft 0.3 ENTRY Default(81bs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 lbs/s.ft. ft' ft 0.3 GREAT/DINING Name: Test Rater Rating Compant: Test Rater D. 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner. WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce c=i COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with /soffit The insulation in an dropped ed ceiling/soffit Y the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninino and wirino. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire qndnkler cover plates and walls or ceilings a. in addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 11/18/2018 1:09 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERIGOP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. 9 Builder Signature: l 1- `� -_ Date: 4, ` Address of New Home: ` , y l^ '""'��� � mil' \ `t \ City/FL Zip:^-HFWEREEfL �k4CtS� 11/18/2018 1:09:37 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 + wrightsoft- Project Summary Job Entire House 13y: QUICK CALCS, INC. For. THE GRAND CARLTON �WWYY"NNEE DEVELOPMENT, FT. PIERCE, FL SCAMED Notes: `v ` St. Lucie i:OlJrtfif Weather. Fort Pierce, FL; US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design T.D 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none). Humidification 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Area (ft) He 1446 Co 1r446 Volume-(ftJ 12511 12511 Airchanges/hour 0.45 0.23 Equiv. AVF (cfm) 94 48 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536Ae030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual' air flow Air flow factor Static pressure Space thermostat Capacity balance point = 32 OF Backup: t kyNCIV9 34600 Btuh @ 47°F 27.OF 1160 cfm 0.049 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/snring multiplier 0.95 Equipment sensible load 24753 Btuh Latent Cooling -Equipment Load Sizing Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req, total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Carder Trade CARRIER AIR CONDITIONING Cond 25HBC536A"030 Coil FX4DN((B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360, Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed + wrlghtv`�soft" RlghtSuBeO Universa1201717.0.14 RSU88101 2017 Apr 11 0 Page 8 �� ...uick Calcs\DocumentslTHE GRAND CARLT014;1448.rup Celt = MJ8 Front Door bees: N wrightsoft- RighWO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LPL, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6795 Email: QUICKCALCS@IOLCOM 1 Room name Entire House BEDROOM 2 ElrpmW wall 156.2 It 49.0 It 3 Room height 8.7 it d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 It 5 Room area 1445.5 W 297.0 W Ty Construction U-value Or HTM Area Load Axea number (Btuhlfta-°F) (BtuhlR') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) . Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 .:IMAoc's . :;0.143 %,n -" 4.00 -'2.55 - 503 -..465 -.. , 18S2 = 1184 72 . - ' 72 288 -' . ;183 0.770 h "°21.56 "'-18:31 '> . "-38 0 815 : -730 - "0.- 'D `_ ., 0 "0 U,J�I' 13A-4ocs 0.143 a 4.00 255 128 83 333 " 212 0 0 0 0 `D 1Aciom 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W " .13A4ccs 0.143 se - 4.00 255 - 34 34 136 86 0 0 6 0 W I--G 13A-4ocs 0.143 s 4.00 255 360 353 1414 899 216 216 865 5W 1Ac1om 1270 s 3555 34.77 7 7 247 241 0 0 0 0 13A-4ws 1Ac1an .0.143 w 400 255 ' 310 237 949 . 603 104 ,72. 288 183 `- 1.270 w. 3556 - 66.21 :32 '.. 2 , - .: 1140 ", 1770 .32 '..� .2 a; 1140 .' •. 1770 4AS-2am-." .0.776 -w- 21.56 ,'19:31 -- 41. 41 •. 880 788 -�'0 �- 0.: .. 0 4=:0 P 12COsw 0.091 2.55 1.28 192 192 489 246 0 0 0 0 C-r:.-':16A30md -, 0.032 - - - .. -'0.98 . -232 1446 - -:1448 . 1295. 3354 zsz '-:. 297 `,- " 266 -' - ..,689 F 22htol 0.989 - 27.69, 0.00 1446 156 4325 0 297 49 1357 0 6 c)AEDeuursion 918 627 Envelope loss/gain 14%1 13349 4204 40M 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 6 1380 3 690 Appliancestother 2000 0 Subtotal Qines 6 to 13) 17848 17520 5053 4925 Lass eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32%a 49% 5654 8536 320/6 49% 1601 2400 Total room load 23503 26055 6653 7325 Air required(cfm) 1160 1160 328 326 � �- wrightsoft- RlghtSuite® Uniwmal 2017 17.0.14 RSU08101' ...ulck CalcsIDocumentsITHE GRAND CARLTON-1446.mp Calc = MJ8 Front Door faces: 2017-Apr-11 09:29:39 Page 1 wrightsoft- Righ"I Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Faz 772-066-6796 Email: OUICKCALCS@AOL.COM 1 Room name WIC IQfCHEN 2 3 Exposed wall Room height O ft 8.0 ft heat/cool O ft 8.0 ft heaticool 4 5 Room dimensions Room area 6.0 x 9.0 ft 54.0 W 1.0 x 172-0 ft 172.0 ft' Ty Construction U-value Or HTM Area (fP) Load AM (fly Load number (Stuh/Wle) (Btutdft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Coal Gross WPIS Heat Cool Gross WP/S Heat Cool 6 W ? - L= '4A5.2arn' 13A-0acs- >:. 13A-4ccs - , 0143 "'0.770'n' 0.143 n' a - .:.:4.00 ..21.56 4.00 "265 19.31 Z65 . -::0 0" 0 - 0 -0- 0 . ,. 0 0 0 .. "0 ';0' 0 0 `0" 0 0 .0 0 - , 0 0- 0 . " ;. 0 ''0 0 yl 11 I(----GD 1Aatom 11DO 1.270 0.390 a a 35.68 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W- Vrr 13AAccs 13A4ws 0.143 0.143 se s - 4.00 4.00 Z65 265 0 0 0 0 0 0 . 0 0 0 0 0 0 .0 0 - 0 0 1Aclom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 -a 13AA= '1Aciom .0.143 1.270-w • w 4.00 35.56 '-255 55.21 0 0 .0 0 0 0- 0 0 0 0 . 0 0" .0 0�- 0 -0 P C ?_r 4A5-tam.-. 12Cesw -16A Vrid . .0.776 0.091 '0.032 w' = - :21.56 2.55 0.90 19.31 1.28 ' " -232 - 0. 0 '. .54 0' 0 ,.. 54 . 0 0 48 0 0 125 - 0 64 ,., .172 .. .0: 64 -172 0 163 ..' -::154 �- ;• -0 82 .' 399 F 22A-tpl 0.989 27.69 0.00 64 0 0 0 172 0 0 0 6 c)AED excursion -9 -170 Envelcpe loss/gain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 '0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appiiancestother 0 2000 Subtotal 01res 6 to 13) 48 117 317 2311 Less edema] load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 48 0 0 117 0 0 317 0 .0 2311 15 Duct loads 32%749Y.15 67 32%a 49% 10D 1126 Total room load Air required(cfm) 64 3 174 8 418 21 3437 153 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed A&T�- wrightsoft- RlghtSuite® Unlversa1201717.0.14 RSU08101 2017-Apr-11 09:29:38 A ...uick CalcslDocumentslTHE GRAND CARLTON-1448.mp Cale = MJB Front Door faces: N Page 2 + wrightsow RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOLCOM 1 Room name BATH BEDROOM 2 2 Fposed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft headcool 8.0 It heat/cool 4 Room dimensions 9.0 x 5.0 It 1.0 x 2D3.5 It 5 Room area 45.0 ft- 203.5 W Ty Construction U-Value Or HTM Area (ft� Load Area Load number (BWWftk'F) (BtuhHN) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 Iak400s .. - _,' 0.143 �_n 4.00 , '.-2,55 40 '. 40 160 -. .. '102' • 128 128 519 - .,326 4A5-2arr7 J .0.770'-n .'121:56 ,-.19.31. ,.. :.0,_.,. .,0 0.. 0,. ,0 ., 0,::- _......0 13AAccs 0.143 a 4.00 255 0 0 0 _0 0 80 56 225 143 tAclom 1.270 a 35.56 87.29 0 0 0 0 24 2 848 2082 1i 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 'Wr 13A-4= 0.143 se 4.00 255 0 0 0 0 34 .34 136 e6 VN 13A-4ocs 0.143 s 4,00 255 0 0 0 0 32 32 128 81 1---13 1Ac1an 1270 s 3556 34.77 0 0 0 0 0 0 0 0 '13A4ccs 0143 w 40D 255 0 0 0 0 0 '0. 0 0 :1Actom:-.,.- 1270 w ^,.35.56 ..55.21 0 0 0:. 0. 0 • 0, 0 4A5-2om •: 0 770 w - 21.56':19:31 - 0 0 _ 0 - 0 .. 0 0 �' 0: '0 P 'C' 12CAsw 0.091 2.55 1.28 0 0 0 0 0 0 . 0 0 ;<; 16A30md- - 0.032 :_ '. :0.90 '..' '232 45,- 45 .. - "40 _. 104 204 - 204.-. .182 '.--_'472 F 22A4p1 0.989 - 27.69 0.00 45 5 138 . 0 204 34 946 0 6 c)AED excursion -16 -85 Envelops lomfgain 339 190 2978 3106 12 a) In ittration 87 24 593 162 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 01 0 Subtotal Qines 6 to 13) 425 214 3571 3498 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Duct loads 320{0 491/6 135 104 32!!L 1131 1704 Total room load 560 318 f49O/o 4702 5203 Alrrequimd(af ) 28 14 232 232 Calculations� byACCA to meet all requirements of Manual J 8th Ed 4F wrightsoftr 2017-Apr-11 09:29:38 �A RightSuOe® Universal 2017 17.0.14 RSU08101 Page 3 ...uick Cales%DocumentMTHE GRAND CARLTON-1446.mp Calc = MJ8 Front Door faces: N I wrightsofV Right-.J® Worksheet Job: Entire House Date: ay. QUICK CALCS, INC. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Emil: QUICKCALCS@gOL.COM 1 Room name LAUNDRY GREAVDINING 2 Faposed well 6.0 ft 47.0 ft 3 Room height 8.0 It heat cool 9.8 It heaticool 4 Room dimensions 7.0 x 6.0 It 1.0 x 526.0 ft 5 Room area 42.0 ft' 526.0 fN " Ty Construction U-%elue Or HTM Area Load Axes f number (Btuh/ftMF) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Hea[ Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 Vy 13A bca, < ` `D 143 R ; , .:4.06 255 _.0 0 0 ' +.o : '.. 255 � 217 . • 869 .'''552 I-G 4Af2om-" _I 770 n .- - -21.56 " 19.31 _ - 0 0 ., 0 .0 .38 " - : 0 : 815 -730 W, 13A-0acs 0.143 a 4.00 Z65 0 0 . 0 0 0 0 0 0 �-GD 1Acl m 1.270 a 35.56 97.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W. AM4ncs 0.143 se .4.00 Z55 0 0 0 0 0 0 0 0 t-C 13A4= 0.143 s 4.00 255 48 48 192 122 0 0 0 0 1Actwn 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4= .0143 - w . 4.00 265 0 - 0 0 0 206 165 661 420 lAclofn , .. . 1.270 w 35.56 . "55.21 . .0 .. - 0 0 01 ..0 0 0 -- 0 05-2orn `, '0 770 . w :21.56 ' `19.31 - 6 0.:- -0 - 0 - ", 41 r , 41 . 886 . _ '788 P 12C-0sw 0.091 - 2.55 1.28 66 56 143 72 0 0 . 0 0 C' , - , 16A30md. , '0.032 - :0.90 .232 42 '42 38 _ ".97 -.526 526, ' 471 1220 F 22A-tpl 0.989 27.69 0.00 42 6 _ 166 0 526 47 1302 0 6 c)AED excursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Roomventilation 0 01 0 0 13 Intemal gains: Occupants (at 230 0 0 2 450 Appliancestother 0 0 Subtotal (lines 6 to 13) 643 298 5994 5112 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistdbution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 3p/e 491/4 204 145 32/ 49% 1899 2490 Total room load 846 443 7892 7602 AirreciUmd(cfm) 42 20 390 338 Calculations approved byACCA to meet all requirements of Manual J 8th Ed wrightsoft- 2017-Apr-11 09:29:38 AAA RlghtSuiteO Universal 2017 17.0.14 RSU08101 Page 4 ...uick CalcslDocumentslTHE GRAND CARLTON-1446.rup Calc=MJB Front Dcorfaces: N wrightsoft Right® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone; 772-466c799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER M. BATH 2 Bposed wall 7.0 ft 8.0 ft 3 Room height 8.0 If heal/cool 8.0 It heat/cool 4 ' Room dimensions 1.0 x 50.0 R 7.0 x 8.0 ft 5 Room area 50.0 ft2 56.0 It - Ty Construction U-value Or HTM Area (fl2) Load. Area (ft2) Load number (BtulJfti°F) (BtuWft2) or perimeter (ft) (Btuh) or pedmeter (ft) (Btuh) Heat Cool Gross HIP/S Heat Cool Gross MRS Heat Cool 6 ;;13A gxs.'. r0143 ,n', . :4.00 .. -255 '8 '. .8 . 321 -.20, ..-'0 b.. 0 .:':0 L-z- 4A5-2om ° 1 � ` 0 770 n' , '.: 21.56 ' .19.31 - 0 .,: - .0 _ .. 0 - :.' 0 : 0. • .. 0 ,, . 0 13A4ocs 0.143 a 4.00 255 48 27 108 ,0 69 0 0 0 0 tAclan 1270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11D0 0.390 a 10.92 11.31 21 21 229 23B 0 0 0 0 w - 13A-4ocs 0.143 se 4,00 2.55 0 0 0 . 0 - -0 0 0 ' . 0 4f/ L-C 13A4ocs 0.143 s 4.00 255 0 0 0 0 64 67 228 145 1Actom 1270 s 3555 34.77 0 0 0 0 7 7 247 241 . 13A4acs 0.143 w 400 255 0 0 0 0 0 0 0 0 �1Aciom-,:.: . 1 270 w 3556 ... 55.21 0, 0 0 0... 0. ;0'., .: 0 '-0 - 4AS-2om;.. .;0.770 -:w.':' 21.56: 19.31= `0 0 0' 0 .:.0 P 12C-05w 0.091 255 1.28 72 72 183 92 0 0 0 0 C 16A30md- ._ 0.032 - .. 0.90 2.32' - 50 -50 45 '. 116 .66 56 60 . .. ._'130 F 22htol 0.989 - 27.69 0.00 60 7 194 0 56 8 222 - 0 6 c)AED excursion -36 -38 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Dines 6 to 13) 913 529 885 516 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 ]5 Duct loads 32% 49% 289 258 32% 49% 280 251 Total room load 1202 787 1166 768 Air required (cfm) 59 35 58 34 Calculations approved byACCA to meet all requirements of Manual J 8th Ed . A wrightsofY Right -Suite@ UnhePage 5rsal 201717.0.14 RSU0810f 2017•Apr-Apr09:age 5 ...nick CaIesVDocumentslTHE GRAND CARLTON-1446.rup Catc= MJ8 Front Door faces: N �- wrightsoft° Duct System Summary Date: Entire House By: QUICK CALLS, INC. 317 ST. LUCIE LH, FT. PIERCE, FL 34946 Phono: 772468-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Extemal static pressure Pressure losses Available. static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (rEL) Heating. 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100tt 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (In) H x W (In) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 OxO VIFx 22.4 115.0 sit BEDROOM h 4702 232 232 0.360 7.0 OxO VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 OxO VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 OxO VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 0x0 VIFx 31.8 135.0 st2 GREAT/DININGA h 3946 195 169 0.300 7.0 OxO VIFx 31.8 135.0 - st2 KITCHEN c 3437 21 153 0.379 6.0 OxO VIFx 17.0 115.0 sit LAUNDRY h 846 42 20- 0.361 4.01 OxO VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 OxO VIFx 0 0 wlc c 174 3 8 0.309 1 4.0 Ox0 VIFx 1 27.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (In) (In) Material Trunk st2 Peak AVF 721 672 U85 918 12.0 0 x 0 VinlFlx sit sit Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx ,- y,-J� wri htsofC 2017Apr-Apr09:28:38 "CA 1 9 RlghtSuile® Universal 2017 17.0.14 RSU08101 Page 1 ...uick CalcslDocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Fmnl Door faces: N Return Branch Detail Table Name PK[4�]Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (n) H x W (n) Stud/Joist Opening (in) Duct Matl Trunk rb1 I Ox0 1 1160 1160 0 1 0 0 0 Ox 0 VIFx 2017-Apr-11 09:29:38 & + wrighttSeft' Right-Suhe® Universal 2017 17.0.14 RSU08101 Page 2 ...Wick Calcs0ocuments\THE GRAND CARLTON-1446,mp Calc = MJ8 Front Door faces: N