HomeMy WebLinkAboutREVISION BUILDING PERMITOFFICE USE ONLY:
DATE FILED: I - M , l q
REVISION FEE: '$—AEj
PERMIT # /90 5�'- 0 S 8'i
RECEIPT # ��+ I :) r
PLANNING & DEVELOPMENT SERVICES RECEIVED BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652 JUL 9 " 2019
(772)462.1553
ST..Lucle County, Permitting
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION SCANNED
LOCATION/SITE BY
ADDRESS: St: Lucie County
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
CONTRACTOR INFORMATION:
STATE of FL REG./CERT
BUSINESS NAME: _
QUALIFIERS NAME:
ADDRESS:
CITY: STATE:
PHONE (DAYTIME):
OWNER/BUILDER INFORMATION:
NAME: CJ V Wl-le Oe4l /
ADDRESS: gdo a " s
ST. LUCIE CO CERT. #:
FAX:
CITY: Olz- STATE:
PHONE (DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
STATE:
FAX:
ZIP:
ZIP: 3 P' 9 .S"Z
ZIP:
SLCCC: 9123109
REVISION
Revised 0616/3011/17
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential P
ECEiVED
Project Name: WYNNE THE GRAND CARLTON 8
Builder Name: WYNNE BUILDING CO
R. JUL 3 O 20�9
Street: 8 MED NORTH
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number: 1904-0589
ST.. Lucie County, Permitting
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft'
b. Frame - Wood, Adjacent
R=11.0 192.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 2
d. N/A
R= ft'
5. Is this a worst case? No
10. Ceiling Types (1446.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1446.00 R'
6. Conditioned floor area above grade (ft2) 1446
b. N/A
R= ft2
Conditioned floor area below grade (W) 0
c. N/A
R= ft2
11. Duds
R ft2
7. Windows(141.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor: Sgl, U=1.04 101.25 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor. N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hot water systems
8. Floor Types (1445.5 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation - R=0.0 1445.50 ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 46.38
Glass/Floor Area: 0.098
PASS
Total Baseline Loads: 48.06
I hereby certify that the plans and specifications covered by
Review of the plans and
F4190 STgl
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
r„.K ; .,,. �, ;•;,,.• „ O
PREP D B
Before construction is completed
O
DATE:
this building will be inspected for
O a
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
lt,
with the Florida Energy Code.
Op WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
7/29/2019 8:43 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INP SUMMARY CHECKLIST REPOR
PROJECT
Title: WYNNE THE GRAND CARL
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: WYNNE BUILDING COPR.
Rotate Angle: 0
Street:
8 MED NORTH
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating Design Daily Temp
V Design Location TMY
Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1446 11568
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
Infil lD Finished Cooled
Heated
1 BEDROOM 301
2408 No
0
1
1 Yes
Yes
Yes
2 WIC 63
504 No
0
1 No
Yes
Yes
3 M.BATH 56
448 No
0
1 Yes
Yes
Yes
4 KITCHEN 192
1536 Yes
0
1 No
Yes
Yes
5 BATH 45
360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2 204
1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY 55
440 No
0
1 Yes
Yes
Yes
8 LAUNDRY 42
336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING 488
3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On. -Grade Edge Insulatio
BEDROOM 52 It 0
301 ft2
_-
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC t ft 0
63 ft2
___
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
_-
0 1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft2
___
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ft2
_-
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ft2
___
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft 0
55 ft2
0 1
0
7/29/2019 8:43 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INP' SUMMARY CHECKLIST REPOR
-
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
-
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft
0
488 ft2
_-_
0
1
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Gable or Shed Metal 1524 ft2
240 ft'
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1446 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2
Under Attic (Vented) WIC
30
Blown
63 ft'
0.1
Wood
3
Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4
Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5
Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7
Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing Solar
Below
pp Space
1
N
Exterior Concrete Block - Ext Ins®EDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
2
W
Exterior Concrete Block - Ext InsSEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.4
0
3
E
Exterior Concrete Block - Ext Ins®EDROOM
4.1 14
0 8
0
112.0 112
0
0
0.4
0
4
W
Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
5
W
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
6
E
Exterior Concrete Block - Ext lnd]ffDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
7
S
Exterior Concrete Block - Ext InGEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0.4
0
8
SW
Exterior Concrete Block - Ext InSEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0.4
0
9
W
Exterior Concrete Block - Ext Ind3EDROOM 2
4.1 2
0 8
0
16.0 ft'
0
0
0.4
0
10
S
Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft'
0
0
0.4
0
11
S
Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
12
W
Exterior Concrete Block - Ext InsdIAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
13
E
Exterior Concrete Block - Ext Ins REAT/DINT
4.1 26
0 8
0
208.0 ft'
0
0
0.4
0
14
N
Exterior Concrete Block - Ext In50REAT/DINI
4.1 20
0 8
0
160.0 112
0
0
0.4
0
15
E
Garage Frame - Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.4
0
7/29/2019 8:43 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017
INPI.
iUIVIMARY CHEGKL15T REPORT
DOORS
# Omt
Door Type
Space Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE
Insulated
ENTRY None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
J Wall
# Omt ID Frame
Panes
Overhang
NFRC U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1 E 3 Metal
2 W 4 Metal
3 S 7 Metal
4 E 13 Metal
5 N 14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes 1.04 0.29 N 32.9 ft2 1 ft 0 in 1 ft 4 in
Yes 1.04 0.29 N 6.9 ft2 1 ft 0 in 1 ft 4 in
Yes 1.04 0.29 N 24.0 ft2 6 ft 0 in 1 ft 4 in
Yes 1.04 0.29 N 37.5 112 1 ft 0 in 1 ft 4 in
Yes 1.11 0.27 N 40.0 ft2 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315 ft2
315 ft2 24ft 8ft
11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .1233
7
HEATING SYSTEM
# System Type
Subtype Efficiency Capacity
Block
Duds
1 Electric Heat Pump/
Split HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split SEER: 15 34.8 kBtu/hr dm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubTpe
Location EF Cap Use SetPnt
Conservation
1 Electric
None
Garage 0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
7/29/2019 8:43 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017
INPI_
WMMARY CHECKLIST REPOR _
DUCTS
/ — Supply
—
—
Return —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic 6
250 ft2
Attic
65 ft2
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programablre
Ceiling Fans:
Jan Feb
Heat ng Jan Feb
[[
(X1 Mar
€
I
f ]]
ri Jun Jul
rr ]]
[X] Aug
[[ ]]
[X] Sep
[ j �C]]
LJ Oct
Nov
Dec
Vent ing I 1 Jan [) Feb
l J l l
[[X1l Mar
Apr
May
Jun [ Jul
lXl
[[ ]] Aug
[[ ]) Sep
lxl [X]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
78
78
78 78
78
78
78 78
78
78
Cooling (VJEH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 lbs/s.ft.
ft2
ft
0.3
GREAT/DINING
7/29/2019 8:43 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSU ION INSPECTION COMPONENT CG— _—RIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON 8 Builder Name: WYNNE BUILDING COPR.
Street: 8 IVIED NORTH Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number: 1904-0589
Y
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
c�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
/soffit
The insulation in an dropped ceiling/soffit
Y pP 9
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Dud shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
EledricaUphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire Rnrinkler cover nlates and walls or ceilinas
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
7/29/2019 8:43 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1446
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.060
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061.
11.0
2. Masonry (Insulation R-value)
1062.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder
Address of New Home: 8 IVIED NORTH City/FL Zip: FT. PIERCE. FL
7/29/2019 8:43:46 AM EnergyGaugeO USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
OFFICE USE ONLY:
Jog
DATE FILED: r(•
REVISIONFEE:
LOCATION/SITE
ADDRESS:
PERMTr #
RECEIPT #
PLANNING & DEVELQPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34962-5652 r
V72) 46$1553
APPLICATION. FOR BUILDING PERMIT REVIS NS JUL 2412019
PROJECTINtibRMATION, Lucie County',, Pern
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
CONTRACTOR INFORMATION:
STATE of FL REGJCERT. #:
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
STATE:
OWNER/BUILDER INFORMATION:
NAME:
CITY:
PHONE
ST. LUCIE CO CERT. #:
FAX:
7n / -8-c/y S FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
ZIP:
r
STATE: ZIP:
FAX:
m
C
B
�
m,
E
IJJ
�
a
H
G
BRADEN 6 BRADEN, A. I. A., P. A.
U
u
W
ZD
w
97rchlfecf5 & 'P lannom
r
N
417 COCONUT AVENUE, STUART, FLCRIOA 3499B
TELEPHONE: (772) 297-925B FAX (772) 287-9293
#AAC-000032
July 2, 2019
St. Lucie County Building Department
Permit #:1904-0589
RE: 8 Mediterranean North
To whom it may concern,
Please note, the field revisions attached are to the electrical riser and the panel schedule to reflect whats being built in the
field. If you have any questions please feel free to call me at (772) 287-8258.
t. Braden
& Braden AIA PA