HomeMy WebLinkAboutCARPORT PLANSFBC APPROVED PRODUCTS T
_
MAXIMUM ALLOWABLE
WIND SPEED
QA
APPROVAL
EXPIRATION
PARTIALLY
PRODUCT CATEGORY
SUB CATEGORY
MANUFACTURER
No. & DATE
DATE
OPEN
ENCLOSED
ENCLOSED
STRUCTURAL COMPONENTS
ROOF DECK
CAROLINA CARPORTS, INC.
FL6596.1-R5
04/05/27
180
180
ISO
26 Gauge AG Panel
10/10117
STRUCTURAL COMPONENTS
STRUCTURAL WALL
CAROLINA CARPORTS, INC.
FL6702.1-R5
0311427
180
180
180
26 Gauge AG Panel
10110117
STRUCTURAL COMPONENTS
FLOOD VENT
FLOOD FLAPS, LLC
FL17381.1-R2
0927119
WA
NIA
WA
Bx18 Flood Flap
10103117
I
EXTERIOR DOORS
SWINGING
ELIXIR DOOR AND METAL COMPANY
FL17996.3-R1
09/1420
WA
156
138
Series 402-14
0129118
EXTERIOR DOORS
SWINGING
ELIXIR DOOR AND METAL COMPANY
FL77996.5-111
09/1420
WA
165
147
Series 407
0129/18
EXTERIOR DOORS
ROLL -UP
ASTA INDUSTRIES INC.
FL6888.1.RS
12/31/19
WA
ISO
174
Model 203 (12' Max. Width)
10/06117
EXTERIOR DOORS
ROLL -UP
CAROLINA CARPORTS, INC.
FL16806.1-R2
1111120
WA
158
138
Steel Roil Up Sheet Door (1Z Max. Width)
01110/18
r
WINDOWS
SINGLE HUNG
MI WINDOWS AND DOORS
- FL17499.1-114
1011723
WA
175
157
Model 185 SH
1229117
c
NOTES:
1. DOORS AND WINDOWS SHOWN MAY BE SUBSTITUTED FOR DIFFERENT PRODUCT LINES AND/OR MODELS, PROVIDED THE FOLLOWING CONDITIONS ARE MET:
A. PRODUCT. SHALL HAVE A VALID FBC PRODUCT APPROVAL
B: COMPONENTS ARE INSTALLED ACCORDING TO.MANUFACTURERS INSTALLATION REOURIEMENTS.
2.F RAMING CONNECTIONS FOR DOOR AND WINDOW FRAMES REMAIN THE SAME FOR SUBSTITUTED PRODUCTS. HEADERS AND WINDOW RAILS MAY BE RAISED OR LOWERED AS NECESSARY TO ACCOMODATE
SUBSTITUTED PRODUCT.
GENERAL NOTES:
1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN
ISSUES, INCLUDING BUT NOT LIMITED TO. PLUMBING, ELECTRICAL, INGRESSIEGRESS, PROPERTY SET -SACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING
REQUIREMENTS'ARE THE RESPONSIBILITY OF OTHERS.
2. THESE STRUCTURES ARE DESIGNED AS NOWHABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE
LIVEAND WIND LOADS. IMPROVEMENTSNOT'SPECIFlCALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR.OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED
PRODUCTS LIST (THIS; SHEET), AND NOT PROVIDED AND INSTALLED BY. CAROLINACARP,OR% INC.; WHICH, EXERT ADDITIONAL LOADS ON. THE STRUCTURE SHALL BE AT THE OWNER'S
RISK, BEGHTOL ENGINEERING AND TESTING: INC., SHALL ;NOT BE RESPONSIBLE'FOR STRUCTURAL DAMAGE' OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS.
3.. ALL STEEL TUBING SHALL SE.50 KSI GALVANIZED STEEL ALL FASTENERS SHALL BE GALVANIZED.OR STAINLESS STEEL
4. ALL COMPONENTS AND CLADDING. SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND SHALLMEET THE DESIGN PRESSURES REQUIRED BY THE
FLORIDA BUILDING CODE (FBC) AT THE LOCATION OF THE BUILDING WITHIN THE STATE OF FLORIDA.
5. ALL FIELD FRAMING CONNECTIONS SHALLSE #12-14 x 314-SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED.
6. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL
BE.REINFORCED WITH 6X6-W1 .4XW1 .4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116.
7. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6' OF EVERY POST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT
REQUIRED FOR CONCRETE FOOTING AND/OR CONCRETE SLAB CONSTRUCTION. SEE GROUND ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS.
8. CONCRETE ANCHORS SHALL BE TAPCON REDHEAD LOT 12' x S' OR EQUIVALENT OR WEJ4T ANKR-TRE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260. OR EQUIVALENT.
9. POSTIRAFTER BRACING: BRACE ON EVERY POSTIRAFTER CONNECTION, EXCEPT FOR END WALLS.
10. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FBC SIXTH EDITION (2017) - RESIDENTIAL,
AND SECTION 1816.1 OF THE FBC SIXTH EDITION (2017)- BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSF IS ASSUMED.
11. 14 GA FRAMING: 2-1/2' x 2.112' TUBE STEEL ITS) WITH 2-1W x 2-1/4' TS NIPPLES.
12 GA FRAMING: 2-1W x 2.114' TS WITH 2' x T TS NIPPLES.
12. ENCLOSED AREAS REQUIRING FLOOD OPENINGS MUST HAVE A MINIMUM OF TWO (2) OPENINGS ON EXTERIOR WALLS. OPENINGS SHOULD BE INSTALLED ON AT LEAST TWO (2) SIDES OF
ENCLOSED AREA, WITH BASE OF OPENINGS SET WITHIN 1-FOOT OF THE HIGHER OF INTERIOR OR. EXTERIOR GRADE. REQUIRED TOTAL NUMBER OF FLOOD VENTS NOTED IN THE FBC
APPROVED PRODUCTS. LIST SHALL BE BASED ON ONE (1) FLOOD VENT PER EVERY 220 SQUARE FEET OF ENCLOSED AREA, SEE TYPICAL FLOOD VENT FRAMING PLAN, SHEET 5 OF 6.
TABLE 1
RAFTER FR'-:__, END POST, GROUND ANCHOR AND PANEL. rENER SPACING SPECIFICATIONS
AVERAGE FASTENER SPACING
ON -CENTERS ALONG RAFTERS OR
MAXIMUM
PURLINS, AND POSTS OR GIRTS
WIND
ULTIMATE
NOMINAL
POST/RAFTER
ONCHES)
INTERIOR
END
RISK
EXPOSURE
WIND SPEED
WIND SPEED
SPACING
CATEGORY
CATEGORY
(MPH)
(MPH)
(FEET)
POSTSIRAFTERS
POSTS/RAFTERS
I
110 TO 150
89 TO 116
5.0
6
6
1
C
151 TO 180
117 TO 139
4.0
6
6
DOTES: 1. Specifications applicable to 26 gauge metal roof and wall panels fastened directlyto 12 or 14 gauge steel tube framing, or 18
gauge hat channel roof pudins.
2. SpedBcatons applicable only for mean roof height of 20 feet or less, and roof slopes of 7° to 27' (1.5:12 to 6:12 pitch). SpaGng
14 IF 30'-Anchor
■7aF.71i1�� ..
MINE
®-.■
MMME
I MINME
IIII'III■III■E
1D SHOWN ON SHEET
/vy-oS1
REVIEWED
CODE COMPI
ST. LUCIE CC
SOCC
SCANNER
BY
St. Lucie County
METAL CARPORT INSTALLATION PLANS
AND DETAILS AND FRAMING AND
FASTENER SPECIFICATIONS
FOR CONSTRUCTION IN THE STATE OF FLORIDA
PREPARED FOR.
CAROLINA CARPORTS, INC.
P.O. BOX 1263
DOBSON, NORTH CAROLINA 27017
PREPAREDBY.,
BECHTOL ENGINEERING AND TESTING, INC.
605 WEST NEW YORK AVENUE
DELAND, FLORIDA 32720
Geitificate of Authorization No; 00005492
THIS IS TO CERTIFY THAT THE CALCULATIONSAND
SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE
UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN
ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1609 OF
THE FLORIDA BUILDING CODE, SIXTH EDITION (2017). THE PLANS
ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA BUILDING
CADS
BECHTOL ENGINEEQ, 1NWV , INI , '_
605 WEST NEW YORKAWNHI. ;
DELAND, FLORIDA 32726 g6536
C.rlm,ate/oraxnayau _,.54 No.
rIlf
•ICI
Flmltla Dcelise N 38538 % STATEOF
CAROLINA CARPD/Ii rq' INC.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
2112/19
AAWBECHTOL ENGINEERING "" RR ;Nis
AND TESRNG, /ne
msrue<¢vm+oc+�.oNddbrzLL,w x.uvui imm,orsxva "ERR "°''G19001
X71 of
BOW FRAME RAFTE __'PEN CARPORT - HORIZONTAL RC_.
BOW FRAME RAFTER ENCLOSED BUILDING - HORIZONTAL ROOF
3OW FRAME RAFTER UTILITY BUILLOING - HORIZONTAL ROOF
FLOOD VENT (As applimble) ROLL -UP DOOR SWINGING DOOR
ROLL-UP DOOR SWINGING DOOR
(As appOmhle) (As app➢mble)
(As a0p➢mble) (As aPDllmble)
mr
TYPICAL SIDE ELEVATION TYPICAL END ELEVATION
NOT TO SCALE
TYPICAL SIDE ELEVATION TYPICAL END ELEVATION
TYPICAL SIDE ELEVATION TYPICAL END ELEVATION
NOT TO SCALE
NOT TO SCALE- NOT TO SCALE
NOTTOSCALE NOT TO SCALE
BOX EAVE FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOX EAVE FRAME RAFTER ENCLOSED BLDG - HORIZONTAL ROOF BOX EAVE FRAME RAFTER UTILITY BLDG - HORIZONTAL ROOF
FLOOD VENT (As app➢mble) ROLL -UP DOOR SWINGING DOOR w .. (As appm(As DP
ROLL -UP DOOR SWINGING DOOlible) afimble) DOOR
(AsP DOOR (As applimble)KFE
�a
TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION
NOT TO SCALE NOTTOSCALE NOT TO SCALE
NOTTOSCALE NOT TO SCALE NOTTOSCALE
BOX EAVE FRAME RAPIER OPEN CARPORT -VERTICAL ROOF
BOX EAVE FRAME RAFTER ENCLOSED BLDG - VERTICAL ROOF
BOX EAVE FRAME RAFTER UTILITY BL_DG--VERTICAL ROOF
FLOOD VENT (As app➢mbla),
ROLL -UP DOOR SWINGING DOOR
ROLL -UP DOOR SWINGING DOOR
(As applimble) (As applimble)
(As applimble) (As applimble)
TYPICAL SIDE ELEVATION TYPICAL END_ ELEVATION
TYPICAL SIDE ELEVATION TYPICAL END ELEVATION
TYPICAL SIDE ELEVATION
TYPICAL END ELEVATION
NOTTOSCALE NOT TO SCALE
NOTTOSCALE
NOT TO SCALE
NOTTOSCALE NOT TO SCALE
•••
BECNTOL ENGINEERINGI4 $ •STING, INC.
605 WEST NEWYORK AVENUE
DELAND, FLORIDA 32720.
CeNflmte -
1
7c
of n Na = 1 �
Florida Llmnse No. 6 j �••''• ,F[ORI
'•G� �
CAROLINA CARPORT-9i -11W.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
TYPICAL BOW RAFTER GABLE END ELEVATION
TYPICAL BOX EAVE RAFTER GABLE END ELEVATION
TYPICAL BOX EAVE RAFTER GABLE END ELEVATION
v12119
NOTTOSCALE
NOT TO SCALE
NOTTOSCALE
BECHTOL ENGINEERING
RR
V�-
NT,
avo resnNc, mG
"4°` RR
XOi G19001
Npova uvau.s .eNo
T3
1 SHEET20F6
26 GA. GALVA—, , METAL ROOF PANELS
FASTENED TO RAFTERS PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS
12
Q3
'24' 16 GA UCHANNEL BRACE
FASTENED TO RAFTER WITH
(2) N72-14 x 3!4' SDFsAT
EACH END (4 PER BRACE)
24'
TYPICAL
INTERIOR RAFI-ER/POST FRAME SECTION - BOW FRAME
NOT TO SCALE
SEE
LID
s
OPTIONAL 24'-1" TO 30' TRUSSED RAFTER - BOW
NOT TO SCALE
12
Q3
'24' 16 GA UCHANNEL BRACE
FASTENED TO RAFTER WITH
(2) 012-14 x 314' SDFs AT
EACH END (4 PER BRACE)
24', MA WM
-24' TO W RAFTF
TYPICAL INTERIOR RAFTER/POST
FRAME SECTION' BOX EAVE - HORIZONTAL ROOF
NOT TO SCALE - -'
SEE
TABLE 1
SHEET
8'-
26 GA GALVANIZED METAL ROOF Pi-'— :
FASTENED TO PURLINS PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS
END (4 PER BRACE)
TYPICAL INTERIOR
RAFTER/POST FRAME SECTION - VERTICAL ROOF
NOT TO SCALE
1.1,718 GAUGE FURRING CHANNEL FASTENED
TO EACH RAFTER WITH (2) 012.14 x 3W4' SELF-DRIWNG
FASTENER SPACED NOT MORE THAN 48.O.C.
TYPIC
3
SEE
TABLE 1
SHEET
tOF6
LENG VARIES OFFENDING ON NUMBER
AND SPACING OF RAFTERS
AL
POST/RAFTER FRAMING PLAN , VERTICAL ROOF
NOTTOSCALE
24.16 GA UCRANNEL BRACE IS TO T PC
46. 16 GA UCHANNEL BRACE (S TO. W PC
BRACE ANGLE SHALL BE MIN.
TO MAIL 45' FROM HORIZON
OPTIONAL 24'-1" TO 30' TRUSSED RAFTER - BOX EAVE LEAN=
—S
TYPICAL BOW RAFTER GABLE END. FRAMING PLAN .
NOTTOSCALE
TYPICAL BOX EAVE RAFTER GABLE END FRAMING PLAN
NOTTOSCALE
I////
ENS
INC.
NO. 3853
•'F�ORIE)
CAROLINA CARPORTS,,
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
2112H9 _
!� BECNTOL ENGINEERING RR Nrs
ANOTESTTNO,,Z
°`O°" RR " G19001
"'•"''''TBSHEET30F6
MINIMUM
REINFORCED WITH
TTHIN W OF EACH
SIDES AND EVERY END
) WALLSECTIONS
MINIMUM
2-12'EMBEDMENT
(2500 PSI MIN.)
�1 CONCRETE BASE RAIL ANCHORAGE
� Not Ta SCBIe '
_ INSTALL 12' x MINIMUM S TAPCON REDHEAD LDT
ANCHOR OR 12' x MINIMUM 5.12' EXPANSION ANCHOR DRILL 5/8' HOLE THROUGH THE 2• WASHERS DRILL 5/8' HOLE THRw . THE
THROUGH BASE RAIL WITHIN 6' OF EACH BASE RAIL AND SECURE TO BASE RAIL AND SECURE TO
RAFTER POSTS ALONG SIDES AND EVERY END ANCHOR EYE WITH 12' DIAMETER TS CONTINUOUS ANCHOR EYE WITH .IR' DUUAETER
WALL POST ALONG END WALL SECTIONS THROUGH -BOLT BASE RAIL THROUGH -BOLT
MIN. 6' Top OF ASPHALT PAVEMENf TOP OF ASPHALT OR STABLE ROUND SURFA E\ OR STABLE GROUND SURFAACE\
: dr 1
MINIMUM
CONTINUOUS 4' CONCRETE PAVEMENT
,o CONCRETE BASE RAIL ANCHORAGE
to Not To SCNe (OPTIONAL- OPEN CARPORTS ONLY)
EYEANCHOR
SIB' ROD 48' LONG
WITH 6• HELIX
OR
SA1•ROD 6D'LONG (SEE GROUND ANCHOR
WITH T HELD(, SCHEDULE, SHEET 1 CF 6,
AS APPLICABLE FORAPPLCABILITY)
BASE RAIL DEEP ANCHORAGE
� Not TOSCWG
DRILL SW HOLE THROUGH THE 2'WASHERS 24' 16 GA U-CHANNEL BRACE (5' TO T POST)
.BASE RAIL AND SECURE TO TS BOW RAFTER
ANCHOR EYE WITH 12'.DIAMETER 48716 GA U-CHANNEL BRACE (8' TO POST) %�
THROUGH-BOLT—� �TS CONTINUOUS - BRACE ANGLE SHALL BE MIN. 45' /
BASE RAIL TO MAX.60' FROM HORIZONTAL, . NO SCREWS
• .�a
(SEE GROUND ANCHOR
MINIMUM 4' 11 SCHEDULE, SHEET 1 OF 6,
FOR REQUIRED ANCHOR)
L CONTINUOUS4'
CONCRETE PAVEMENT
EYEANCHOR
CONCRETE BASE RAIL ANCHORAGE
1E Not TO SC810 (OPEN CARPORTS WHERE SLAB EDGE DISTANCE DOES NOT
MEET MINIMUM EDGE DISTANCE SHOWN IN DETAIL IS)
TS TRUSSED RAFTER CHORD,
OR NONSTRUCTURAL HEADER
TS END POST OR DOOR/ /
WINDOW FRAME POST
TS BASEAVINDOW RAIL OR
NONSTRUCTURAL HEADER
(12 GA IF ROLL -UP DOOR FRAME)
POST
4 Not To
2'x 7 16 GA ANGLE CUP
SECURE TO POST (EACH SIDE)
AND RAFTER CHORD/RAIL WITH
(4) NIZ-14 x 3/4' SDFs, (2) ON.
TOP OR BOTTOM, (2) ON SIDE
NOTE. AT ROLL41P DOOR
OPENINGS, POST SHOULD
BE FLUSH WITH RAIL END.
CUP POST TO RAIL ONLY ON
SIDE OPPOSITE THE OPENING.
TRUSS CHORD, OR
ZAL HEADER CONN. DETAIL
Gnx BOX.RAFTER/POST DETAIL
e
TS
1-12•x 1-1/2 xT 16 GA CUP
ANGLESECURETO
POSTAND BASE RAIL
WITH (4) 012-14 z 3/4- SDFs,
(2) ON TOP, (2) ON SIDE,
CONTINUOUS BASE RAIL
;END POST/BASE RAIL CONN.
Not To Style
IN
3'
TO
CONTINUOUS
EYEANCHOR (SEE GROUND ANCHOR
5/8' ROD 3W LONG SCHEDULE, SHEET 1 OF 6.
WITH DBL 4'HEUX FOR APPLICABILITY)
(S TO T.POST)
(8'TO14' POST)
45'
4L NIPPLE TO
BASE RAIL
3• `9' LONG TS NIPPLE
T SECURE RAFTER AND POST TO
NIPPLE WITH (4) #12.14 x 3/4'
7AFTER POST SELF-DRRLNG FASTENERS
�R BOW RAFTER/POST DETAIL
:� Not To Smle
TS POST
(12 GA IF ROLL -UP DOOR FRAME)
rxr
(2) ON TOP OR
(12 GA IF ROLL -UP DOOR FRAME)
TS WINDOW RAIL OR GRT
FOR VERTICAL SIDING OPTION
NON-STRUCTURAL HEADER, WINDOW
RAIL, OR GIRT TO POST CONN. DETAIL
�T Not TD Scale
BASE RAIL ANCHORAGE
tv Not To Seale
:i47y-T_111
POST/BASE RAIL CONN. DETAIL
� NotTo SCaIe '
CAROLINA CARPORTS, INC.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
AND TES2N2N9
BECNTOL ENGINEERING - RR .
RNO /n¢
MR
RR 'P' G19001
""^"EOTB -I SHEET401
2]¢72. 18 GA ANGLE CLIP
SECURE TO POST AND
RAFTER WITH (4) #12-14 x 3/4'
SOPS, (2) ON BOTTOM,
(2) ON SIDE
OR
2'x4' 16 GA PLATE
SECURE TO EACH SIDE OF
TS END POST PO.ST/RAFTER CONNECTION
WITH (4) #12-14 x 3/4' SDP%,
4 (2) ON POST, (2) ON RAFTER
r,1 END POST/RAFTER.CONN. DETAIL
Not To Sale
2.16
#12.14 x W. SDP% (2) ON TOP,
(2) ON BOTTOM
RAFTER POSTAND GABLE
RAIL WITH (4)/H2-14 x 3/4• SOFa
(2) ON TOP, (2) ON SIDE TS GABLE RAIL
—TS RAFTER POST
GABLE RAIL TO RAFTER POST
%1 CONNECTION DETAIL
� Nol TO Scele '
2-1/4' FOR
12 GA FRAMING
2-12' FOR
14 GA FRAMING
16 GAUGE U-CHANNEL BRACE
FASTENED TO THE POST AND
RAFTER WITH (2) #12-14 x 3/4• SOPS
AT EACH END (4 PER BRACE)
BRACE SECTION
NotToSale
NIPPLE TC
DBL. HDR.
6' LONG TS NIPPLE
SECURE EACH WITH
(4) #12.14 x 3/4'
SELF-DRILUNG FASTENERS
TS POST
,(-.1 RAFTER POST/DBL. HEADER DETAIL
Not To Scale
16
GABLE RAIL
TO NIPPLE WITH (4) #.12-14 x 3/4'
SELF -DRILLING FASTENERS
I RAFTER POST
GABLE RAIL TO RAFTER POST
%1 CONNECTION DETAIL
/ Io Not To Sale
1-12. 16 GAUGE FURRING CHANNEL FASTENED
TO EACH RAFTER WITH (2) #12-14 x aW SDF
SPACED NOT MORE THAN 43. O.C.
26 GA METAL ROOF
PANEL
ROOF PANEL ATTACHMENT
(ALTERNATE FOR VERTICAL ROOF PANELS)
Not To Scale
24'
POST
LONGIL NIPPLE
SECURE WITH(4)#12-14x 301'
SELF-0RBLNG FASTENERS
DOUBLE TS HEADER
NIPPLE TO
DBL HDR.
�1 RAFTER POST/HEADER DETAIL
Not To Smle
NIPPLE TO 3116' 6' LONG TS NIPPLE
RAFTER SECURE WTTH(4) 012-14 x 3/4'SDPs
I 12' LONG TS NIPPLE.
SECURE POST TO NIPPLE
WITH (4) #12-14 x 3/4' SDF'a,
A U-CHANNEL BRACE IS TO T POST)
U-CHANNEL BRACE IS TO 14' POST)
BRACE ANGLE SHALL BE MIN. 45•
TO MAX 60' FROM HORIZONTAL -
TS RAFTER POST
SIDE EXTENSION.
RAFTER/POST DETAIL _
Not To Scale
TS LEG
IG
TS SAS
TYPICAL FLOOD
VENT FRAMING PLAN
NOTTO SCALE
SEE GENERAL NOTE No. 12, SHEET 1 OF 6:
x 3/4'
RAFTER POSTBASE
�1 BASE _RAIL CONNECTION DETAIL
�� Not Td Smle
POST
Tx4.16 GA PLATE (ONE REQUIRED)
SECURE TO EITHER SIDE OF
POST/RAFTERCONNECTION
WITH (4) #12-14 x 3/4' 5130%
(2) ON POST, (2)ON RAFTER
25272' 16 GA ANGLE CUP
SECURETOPOSTAND
RAFTER WITH (4) #12-14 x 314'
SDFs, (2) ON RAFTER,
(2) ON POST
"OLEAN-TO RAFTER CONN. DETAIL
a/
�t111'IIIIIII�
BECHTOL.ENGINEERINC�
i
60SWESTNEW YORK AVENU •'
DELAND, FLORIDA 32720 : : '•�,\DENSE •'•T0
Dt
/
i
Cei66c olAUNorizedon
8538
;.
Thomas SWIM. � �
-Florida Ucensallo.
of -
i O. STATE
NAL`�`�
CAROLINA CARPORTS, INC.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
2/12/19
MBECHTOL ENGINEERING
AND TESRNG, lne.
oxmanc ®nmerK onmNow, uo W+wui nsmc oxemo '- RR . — _G19001
TBSHEETS OF
VERTICAL SIDE OPTION
GIRTS
(Typical)
SEE
TABLE 1
SHEET
WITH
WALL OPENINGS POST/RAFTER/GIRT FRAMING PLAN
NOTTOSCALE -
a
BOX EAVE FRAME RAFTER ENCLOSED BLDG : VERTICAL _SIDES
ROLL -UP DOOR 'SWINGING DOOR
(As applicable) (As applicable)�
I\ .
TYPICAL SIDE ELEVATION
NOT TO SCALE
TYPICAL END ELEVATION
NOTTOSCALE
GIRTS
(Typical)
1-12' 18 GAUGE FURRING CHANNEL FASTENED TO
EACH RAFTER WITH (2) #12-14 x 314- SELF -DRILLING
I— FASTENER SPACED NOT MORE THAN 48' O.C.
r OPENING FOR SWINGING DOOR
/ WITH NONSTRUCTURAL HEADER
�I��I�I�
I-ICI-I�SIlI�I�I
�I�I�I�lo101-li�l�I�I-I
vII/II\v
��I\v
■_;lip:
,�_�
-I,
I �
TYPICAL POST/RAFTER/GIRT FRAMING PLAN
NOT TO SCALE 7 .
BOX SAVE FRAME RAFTER UTILITY BLDG - VERTICAL SIDES
.. ROLL -UP DOOR SWINGING DOOR
.TYPICAL SIDE ELEVATION
NOTTOSCALE
(As
TYPICAL END ELEVATION
NOT TO SCALE