Loading...
HomeMy WebLinkAboutSUBMITTED DOCUMENTS' F1 -OFFICE USE ONLY: DATE FILED:- 4c'I IN PERMIT#: 0704-0331 REVISION FEE: - =` RECEIPT #: aZ1 ST.LUCIE COUNTY ,DEPARTMENT OF COMMUNITY DEVE BUILDING & ZONING 2300 VIRGINIA AVENUE " FORT PIERCE, FLORIDA 34982-56 772=462-1553 APPLICATION FOR BUILDING PERM PROJECT INFORMATION 1. LOCATION/SITE - ' ADDRESS: 6951 - 6997 Hancock nrive, Port St. Lucie 2. DETAILED DESCRIPTIONS OF PROJECT REVISIONS: Change,fromSpace Coast Truss r to Chambers Truss, Truss drawin s attached 3. CONTRACTOR INFORMATION: ST. OF FL REG/CERT #:—=0 25 9 9 ST LUCIE COUNTY CERT BUSINESS NAME: Wynnes Development Corporation.'- QUALIFIERSNAME: r Matthew Lyle Wynne ADDRESS:, 8000 S. US1, Suite-.402 CITY: Port St. Lucie STATE FL ZIP: 349S2 PHONE (DAYTIME): 772-878=5513 FAX# 772-878-7656 4. ARCHIT/ENGINEER:, NAME: Braden &- Braden ADDRESS: 417'-Coconut Ave. CITY: Stuart STATE FL ZIP: 34996 PHO'E(DAYTIME): 772-287=8258 FAX# 772-287-8283 17JI9102' _ WYNNE DEVELOPMENT CORPORATION 8000 S. US 1, SUITE 402 PORT ST. LUCIE, FL 34952 772-878-5513 FAX: 772878-7656 NO DATE: March 11, 20 TO: St. Lucie County Building and Zoning FROM: Matthew Lyle Wynne, Wynne_Development Corporation SUBJECT: Truss Contractor change , I am changing'from Space Coast,Truss to Chamber T s n Permit#0704-03311,. _ .. Matthew Lyl nne •1 Sa- fit: ��nr Building Code Compliance Division 2300 Virginia Avenue Receipt Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 http://www.stiucleco.org/public_works/permitting.htm _ Date: 19 March 2009 - . Receipt,#: - 0000068277 - Job Address: 6951-6993 HANCOCK DR - - 'ermit Number: SLC- 0704-0331 Received By: gersteml - - Amount: $50.00 Paid With: ck Gard Number: Check Number: 028728 Paid By: Wynne building corporation Sign: OFFICE USE ONLY: DATE FILED: 4 PERMIT#: 0704-0331. REVISION FEE: RECEIPT #: togbPS ST. LUCIE COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT $UILDING & ZONING 2300.VIRGINIA AVENUE FORT PIERCE, FLORIDA 34952-5652 772-462-1553 APPLICATION FOR 1. LOCATION/SITE PROJECT 6951-6997 Hancock Dri%e3&N rt Saaint 2. DETAILED DESCRIPTIONS OF PROJECT have c Front columns shall be 16"xl6" column block New column has been added under girder CRE SEE ATTACHED LETTER FOR DETAILS OF REVISION 3. CONTRACTOR INFORMATION: ST.OFFLREG/CERT#: ec:ro3599 ST. LUCIE COUNTY CERT #: 0 8 8 9 8 BUSINESS NAME: Wynne Development Corporation QUALIFIERS NAME: Matthew L. Wvnne ADDRESS: CITY: PHONE (DAYTIME): 4. ARCHIT/ENGINEER: 772-878-5513 FAX# 772-878-7656 NAME:. Braden & Braden, A.I.A., P.A. ADDRESS: 417 Coconut Avenue CITY: Stuart STATE FL ZIP:34996 PHONE (DAYTIME): 77 - 87-8258 FAX#772-287-8283 12/19/02 BRADEN 6 BRADEN, A. I. A., P. A. - rchilecZ5 & 91anner5 417 COCONUT AVENUE, STUART. FLORIDA 3499E TELEPHONE: (772) 2S7-8258 FAX (772] 2S7-82B3 #AAC-CCC032 St Lucie County Building Department Re: Carlton Square, US 1 Port St Lucie RE Permit # 07-04-0331 To whom it may concern, Please note the following items have changed: - The sheer walls have been re -arranged from a single cell at.€ every other tenant wall alternating sides. - The four columns in the center of the building at the angle bottom with 16 x 16 column blo on the top. The. outer 20 x 16 deep poured concr In all four columns ther two #7 bars from the top of th mns and terminate at thee - ALL other front columns sha "x 16" column block with 4 #5 bars vert. Rebar will cha gg,((2) #7 bars from the top row of beam blocks. ! - A new column has been added w-nder gird submitted. - In Bay #13, above the lintel and o co approximately 8" x 64" long that wiI continue through the beam block an nto bar. There shall be six #5 bars (verti seen needed while in the field. The logo - The rear wall of bay #13 shall have a new girder truss GRE above. Horizontal Steel into this new beam. GRE. A detail has March 3, 2009 each tenant wall to a wall,7'-4" long at 20 x 20 poured concrete columns at the •enter building columns shall have a 20 x 7 vertical bars. The re6ar will change to the beam block. � block above filled with concrete and lumn block and terminate at the top provided foundation plan of intermittent block, a oured concrete beam, e at the top of the adjat, ck and shall have two #7 bars that e poured beam, :;There III be two #5 bars placed below the #7 that will tie into the beam. Contractor shall add any extra steel as shown on the attached plan and marked beam A. 16" x 120"long concrete tie beam with (2) #7 bars cont. to carry Oblie into bond beam. All vertical steel from filled cells below shall tie t i In Bay #14, above the lintel and one course of intermittent block, there shall be a poured concrete beam, approximately 8" x 68" long that will terminate at the top of the adjacent beam block and shall have two #7 bars that continue through the beam block and into the poured beam. There also will be two #5 bars placed below the #7 bar. There shall be six #5 bars (vertical steel) that will tie into the beam. Contractor shall add any extra steel as seen needed while in the field. The location is shown on the attached room plan and marked beam B. If you have any questions please feel free to call me at 287-8258. Th " /ou 1L R BRADEN AIA Braden & Braden AIA PA Code Compliance Division • 2300 Virginia Avenue Ft. Pierce, FL 34932 Phone: (772) 462-1553 Fax: (772) 462-1578 http:i/www.stlucieco.org/publie—works/pemitting.htm Date: 04 March 2009 .lob Address: 6951-6993 HANCOCK DR Received By: gersteml Paid With: CK Paid By: WYNNE BUILDING CORPORATION Building Receipt Receipt #: 0000068045 'emit Number: SLC- 0704-0331 Amount: $50.00 �rcc it Card Number: Check Number: 028714 Sign: 3 r- M, �x�: 11 S- S 7 ST LUCIE COUNTY FIRE DISTRICT Office of the Fire Marshal Plan Review 5160 N.W. Milner Drive Telephone: 772.621.3322 Port Saint Lucie, FL 34983 FAX: 772.621.3604 THE FLORIDA FIRE PREVENTION CODE, 2004 EDITION IS CUR Y ENFORCED. The Code is based on NFPA 1 and NFPA 101, 2003 Florid c• ition: Jurisdiction: at SG G O i #: B-07-450 Project Name: Carlton Square (Lexington Square) B Permit #: 0704-0331 Address: 6951-6993 Hancock Drive ®� Contractor Wynne Development one # 772-878-5513 Contractor's Address: 8000 South US1 City: PSL State: FI Zip Code: 34952 Architect/Engineer: Braden&Braden Phone # 772-287-8258 Occupancy Type: Mercantile AS Permit: Required Construction Type: 3B FA Permit: Required Square feet: 24951 FFP Permit: Number of stories: 1 Access Box: Occupant Load: Access Key Switch: NOTE 1. All revisions, including the electronic copy must be received prior to permitting. 2. The Fire Marshal requires 24 hour notice on all inspections. 3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 4. Failed inspections require payment of fee prior to rescheduling of further inspections. 5. Penetrations through rated assemblies shall be of proper UL design. Design criteria shall be submitted with the construction plans. 6. Fire alarm panels shall be located indoors within a controlled environment. 7. Plans and construction are subject to corrections in the'field to maintain code compliance. An electronic version of the construction plans on a CD is required. The file format shall be .pdf only. The CD shall contain a sheet index file. Files shall be separated by discipline. Files names shall match construction documents sheet numbers. L Required Revisions 1. A separate permittreview shall be required for the fire sprinkler and fire alarm system. 2. The fire alarm panel shall be located in air-conditioned space. 3. The fire service underground piping shall meet NFPA13 and NFPA 24 specs.. 4. Read all notes above. 2007.10.01 08:27:30-04'00' "l s .,uue kinnne 777- qw r wow 'a'+r�ra `N I'M 1Y NNYf�ituYAy M" YIAi BCIS Home I Log In ; Hot'Topicsj Submit Surcharge! Stats & Facts! Publications! FBC Staff 11 q1 Product Approval /* 3 I ) USER: Public User _ a Product Approval Menu > Product or Application Search > Application List > Application Detail, i' FL`# FL6309-111 Application Type Revision Code Version Application Status Comments Archived . Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative 2004 Approved South Florida Metal Supply, Inc.' 2783 S.E. Monroe Street Stuart, FL 34997 (772)223-4055 sflmetalsuppiy@bellsouth.net James L. Buckner, P.E. @ C-Buck, Inc jimmy@cbuckinc.net Search(" I of 9/ 17/2007 2:33 1 """"` http://www.floridabuildi,ng.org/pr/Or_app_dtl.aspx?param=WGEVXQwtDquQX8AcxAgw Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who James L.,Buckner, P.E. developed the Evaluation Report Florida License 'PE-31242 Quality Assurance Entity Keystone Certifications, Inc. Validated By Wendell-W: Haney, P.E. Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated FL6309 RICOI CertOfIndep FL6309-R1 pdf Standard UL 580-94 with Revisions through February 1998 Method 1 Option D 08/03/2006 Year 1998 2 of 4 9/17/2007 2:331 - - -.•, nttp:i/www.tioriciabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQWtDquQX8AcxAg% • Date Pending FBC Approval 08/07/2006 Date Approved 08/22/2006 Summary of Products FL # Model, Number or Name Description 6309.1 1- "5-V Crimp" Minimum 26 Gauge Steel, Maximum 24" Wide (Net Coverage) Panel, Attached to Wood Deck Limits of Use Installation Instructions Approved for use in FL6309 R1 II 1-5VCrimp 24in 26GaSteelonWood INSTALLATION- R1. pdf j HVHZ: No Verified By: James L. Buckner, P.E. Florida P.E: #.31242 Approved for use outside 'i Evaluation Reports I HVHZ: Yes FL6309 R1 AE 1-5VCrimp 24in 26GaSteelonWood EVALREPORT Rl.pdf Impact Resistant: No Design Pressure: +N/A /-50.50 Other: Design Pressure (Rows 16" o.c.) = -50.50 .psf. Design Pressure (Rows 8" o.c.) =-106.75 psf. The -• I required design wind loads I shall be determined for each project. The maximum fastener spacing listed herein Shall not be exceeded. All I rational analysis computations shall be prepared by a qualified design professional, as required by Florida Building I Code, Section 105 or 106. This product is not approved for use in the High Velocity Hurricane Zone. Refer to i Evaluation Report. 3of4 - 9/17/2007 233 I 4 Y 4. i.. l p`r http: //www. tl oridabui I d ing. orgtprlpr_app_dtl.aspx?param=wGEV XQwtDquQX8AcxAg% Back LNexti DCA Administration Department of Community Affairs Florida Building Code online Codes and Standards 2555 Shumard Oak Boulevard Tallahassee, Florida 32399-2100 (850) 487-1824, Suncom 277-1824, Fax (856) 414-8436 © 2000-2005 The State of Florida. All rights reserved. Copyright and Disclaimer Product Approval Accepts: VW51afl Bobby SYiufatl "4t.v' APV0.gVFP VEfl IPYY .l i 4 of 4 9/17/2007 2:3. C-BUCK Engineering In C-Buck, Inc. Florida Certificate of Authorization 78064 Specialty Structural Engineering Installation Method Of South Florida Metal Supply, Inc. "5-V Crimp" Metal Roof Assembly for Florida Product Approval # FL 6309.1-R1 Florida Building Code 2004 Method: 1 - D Category: Roofing Sub - Category: Metal Roofing Product: 5-V Crimp Metal Roof Panel Material: Steel Panel Thickness: 26 Gauge Minimum Panel Dimensions: 24"Maximum (Net Coverage) Support Type: - Wood Deck Prepared for: South Florida Metal Supply, Inc. -2783 S.E. Monroe Street Stuart, FL 34997 . Prepared by: James L. Buckner, P.E. Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Engineer Assistant: Gil Samson Report No. 06-132-5V-IM-Rl Date: 3 / I / 06 *Revision: 7 / 13 / 06 (dg) Contents: Installation Method Pages -I - 4 u 4L V Ja> L, Buckner, P,E. Florida 1) . # 31242 '71/3T0(0 1334 S. Killian Drive, Suite 4 - West Palm Beach, Florida 33403 Phone: (561)491-9927 - Fax: (561)491-9928 - Email: cbuck@cbuckinc.net — FL #: FL 6309.1-111 Date: 3/1/06 "Revision: 7/13/06 � ii Report No.: 06-132-5V-IM-RI � liJ4 ',"� naj'ine-�sring Page 2of4 C-Buck, Inc. Florida Certificate of Authorization 48064 Specialty Structural Engineering Evaluated Installation Panels shall be through -fastened to the deck with minimum #14 x Method: minimum penetration through deck 3/16", hex -head, self -tapping, corrosion resistant, woodgrip screws, per ANSI/ASME B18.6.4, with weather sealing washers. For 50.50 usf Design Pressure: Install the "5-V Crimp" to the deck with screw rows spaced 3" from all ends and maximum 16" o.c. thereafter, along the length of the panel. Within rows, screws shall be spaced nominally 12" o.c., across the width of the panel, at the top of the major corrugations. Install system in compliance with the installation method described herein, along with the attached drawings. For 106.75 nsfFor 106.75 Design Pressure: Install the "5-V Crimp" to the deck with screw rows spaced 3" from all ends and maximum 8" o.c. thereafter, along the length of the panel. Within rows, screws shall be 'spaced nominally 12" o.c., across the width of the panel, at the top of the major corrugations. Install system in compliance with the installation method described herein, along with the attached drawings. Manufacturer's Refer to the manufacturer's installation instructions as a supplemental Installation Instructions: guide for attachment. i` - 1' FL #: FL 6309.1-RI Date: 3/1/06 *Revision: 7/13/06 ReportNo.: 06-132-5V-]M-RI a C— r C Kng.1"t�'e1"®.1I6. Page 3 of4 C-Buck, Inc. Florida Certificate of Authorization # 8064 Specialty Structural Engineering Installation Method South Florida Metal Supply, Inc.. "5-V Crimp" (26 Ga. Min.) Panel Attached to Wood Deck r 24" Maximum Net Coverage Panel Profile Nominal 12" o.c. Assembly Profile Nominal 12" o.c. ' FL #: FL 6309.1-R1 Date: 3/1/06 *Revision: 7/13/06 Report No.: 06-132-5V-IM-RI C-BUCK EnghleerIng Page 4of4 C-Buck, Inc. Florida Certificate of Authorization # 8064 Specialty Structural Engineering Installation Method (Continued) South Florida Metal Supply, Inc. 1'5-V Crimp" (26 Ga. Min.) Panel Attached to Wood Deck Panel Fasteners - #14 Hex -Head Self-Taooina CDX Plywood - Minimum 15/32", or wood plank Assembly Isometric View — Design Pressure 50.50 psf Panel Fasteners - #14 Hex Head Self Taooina_ CDX Plywood - Minimum 15/32", or wood plank Assembly Isometric View — Design Pressure 106.75 psf 976 LINCOLN AVENUE PRINCIPAL PM: (651) 310-9960 FAX: (651) 310-9961 SAINT PAU-, MINNESOTA 55105 EN INEE�tING WWW.PR INCIPALENGINEERING.COM PROJECT NAME: CARLTON PLAZA WORK ORDER: 45288 DATE: `7/6/2607 - Pole Length, ft.= 28 Wind Velocity, mph = 140 Tip Width, in. = 5 Exposure Category = C Taper, in./ft = 0.162 Building Classification = II Trial Pen., ft= 8 Importance Factor= 1 Width of Btm. = 9.536 Soil Parameter = 150 Per 2004 Florida Building Code Sect. 1819.6 WIND LOAD ANALYSIS DESIGN STANDARD: ASCE 7-02 ZONE b A Kz G C P Y. M 0-15 ..7.03 8.78 0.85 0.85 2 636.9831 7.5 4777.37 15-20 5.41 2.25 0.9 0.85 2 172.9735 17.5 3027.04 Fixtures 4.00 0.9 0.85 1.6 245.7792 20 4915.58 Antenna 0 0.9 0.85 1.6 0 20 0.00 Totals Sum P= 1055.736 Sum M= 12719.99 POLE EMBEDMENT DESIGN STANDARD: 2004 FLORIDA BUILDING CODE d b h Mu Pu 8 1.0736 12.04846 16218 810.9 S1= 800 A= 2.8764 ADEQUATE EMBEDMENT?• B24/2'(1+(SQRT(1+(4.36'C20/B24))))<C8 YES 5 { 45288 SHEET ---OF ------------------------------------------------------------------- --- ---------------------------- I PRE -CAST SPECIALTIES, -Inc." I S-POLE : DESIGN OF PRESTRESSED AND PARTIALLY PRESTRESSED - SQUARE TAPERED CONCRETE POLES CopyIright:,(C) 1991 by Pre/Soft GEOMETRIC DE�SCRIPTI'.ON Total length = 28.00 ft Embedment length = 8.00 ft Tip dimension = 5.00 in Void diameter at 0.00 ft from tip = 0.00 in Taper = 0.162 in/ft Butt dimension = 9.54 in Void diameter at 0.00 ft from butt = 0.00 in CONCRETE DATA ALLOWABLE STRESSES f'c = 6000 psi fc = 3360 psi f'ci= 3500 psi fci = 2100 psi Ec = 4417060 psi ft = - 651 psi Eci = 3373585 psi fr = 581 psi We = 144 pcf Stress -strain model : ACI MISCELLANEOUS DATA LOADING DATA Strength factor \ = 0.90 Pa = N.A. Number of sections = 16 _ Pcr = N.A. Center of gravity 11.2 ft Pu = 0.80 kips Weight 1.5 kips PDp = N.A. Strand pattern type: Standard d = 1.00 ft Direction ORTHOGONAL REINFORCEMENT SUMMARY -------------------------------- -------------------------------- Reinf. Strand \ Grade Strand' As Ast Pull/ea Cover Type Qty (in) (ksi) type (in2) (in2) (kips) (in) ------------------------------------------------------------------- Active 4 7/16 270 L.R. 0.115 0.460 17.30 1.500 ------------------------------------------------------------------- CRA 8-30-07 --------------------------------------------------------------------------- Presoft, Inc. 1240A East -Main Street, Bartow, FL 33830 Tel: (863) 533-1054 Fax: (863) 533-1803 D 0 I N I (D mcn.cwNro�omJmcnawNHo I �rt 1 N- I o I � H H r r H r H H r N I I H J J J m m l0 O O H N W Ja (n J m 0 I M rNio�NJ(n In JO I M(- W MW M H N J 01 1p m N W 0 O\ r J (JI Ol W m O W m I N F'- H H 1 0 (D I (D (A r r H H r r H H r N 1 ro rt 1 0 D) H H N <0 .G 1p Cn N lO J Cn (n (n J O N H I 'Ki F'- (D H N J m l0 m N W 0 01 H J (n Ol W m 0 1 `-' m I N rrH I r m m01 Ol J J tjw Ln m m l0 l0 O O•r N w .� 1 M rt 61 O (n O dl N l0 m .G' N r 0 0 I M (] H Ol lO N m Ol lO Ut Ol IV .P H W m O- I N (D O N D r H H H .r H H 1 ro N (D O\ Ol 01 J J m m l0 l0 O O N N W .G (,n I O N Ul F'- 01 l0 iA N .P m a1 l0 W W m O I I I I H C] r rr H.H r r r H N N••NN N W W I (D O r N W. . 01 J m lO O N .G 01 W O W I ro r z M (n N r lO W O N On M I N (D n N-m .G w m w 0 I F•- W H I N (D I (D I (D 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o i ro 0 • 1 M O 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 l rt H H H r r r H H 1 • M H lO O N W (n m O W 61 O W J r dl O 01 H I l rt x 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 ro O O O O O O O O O O O O O O O O O l rt I W W N N N r H H N N l0 J (n W H l0 m J N •Ca .A Ol I I "S' . I M O W O l0 O W m UI W .L� OD tO (P H 1p l0 O H 1 rt I H H H H H H H I x N .A W W N H O l0 10 m J J 61 U (n Ja H I I x I M rt m m l0 O I rt I I I w t7 I l l l l l l l l l l l l l l l l l p I�- 'i3 I (D I H r H r r H H I (D I O I I N I N M v+awNmJrncnawN m 'ti 1 0 1 1 (n I M C7 I I N N N N N r H r r H H CD] m. .C. N r lO J (n .P N O m. wH O I FA rt I I . En O W (n m O W (n m O W Cn M O W (n m O :rt 'J I I En Y P. n I ro N I H F I ED' I ..I Lo [n W N O l0 m J Ol In .P W N N H I Cf"(D G 0 I, m N J N l0 Ol .P W N W .P Ol m H Ul l0 .P 1 Ul O I `— cQ 0 r I H I ED m ? r 1 H • 1 rt N '1 0 I m H O O lO m m J. N. .p W. r. C'1 . ., I rF (D' I M.- I - C 1 0 • I I '3 I . m I H �A ,kD (D I I lO w m m W-�] J J J,O1 0) O1 (n (.n (n N I . P- a O 1 T, z . . . . . . . . . ._ . . . . I Cn W O J .G H m 01 W O I C7 rt rt I `-' .T P. I y., I C7 I •_ O 1 Z. I ro W I 70 oOOo. oO. OOoo O. 3 . . . I Imo-,/ O 1 ( I H 0 0 0 0 0 0 0 0 0 0 0 0 0 0 057 O I L I F' - 3 I m ¢ J H CD 1 0 N m m J J W (n In (n .A W w W N I F'- 'y I 'V •I C'1 W N W m J W m m W 10 Ot H J W W O Ol W O J I�:j H I ',i7 I 1 H 0 m J Ol Cn .P .Q w W N N N H H H r I H H I V] I r W Ol t0 W J N m O J N O m N I W w w m .� m m m W W m mm .� W .o l (D I I I ¢ I I I [j7 M ro l t77 m [i W W W W w W N N . ,J I I tq C J W N O O 0 J .A W N 01 (n 1 .7 1 r (DD 1 C H w m Ol N w J w J W m .P o m W l0 Cn H W m .A O I '--' I H I H H I rt I O I F'- I I Z (D I m 1 O .� W w W W W w W N N N N l 1 I r=] . F'- K J W N O J .� W N O to J O (n 1 � N I I J W m W M .P O al M W m W l0 N H J W m � O I 45288 SHEET_OF_ ULTIMATE MOMENT CAPACITY AND STEEL STRESSES - ORTHOGONAL LOAD ,. ------------------------------------------ Mu \ Mn c --------------------------------- a Steel Stresses at Ultim Section (active) (passive) # --------------------------------------------------------------------------- (k-ft) (k-ft) (in) (in) fps (psi) fs (psi) 0 0.00 6.79 2.55 1.91 138692 - 1 0.60 8.05 2.40 1.80 146637 - 2 2.00 9.25 2.45 1.84 156987 - 3 3.40 10.77 2.46 1.84 168928 - 4 4.80 12.34 2.47 1.85 180253 - 5 6.20 13.93 2.49 1.87 190824 - 6 7.60 15.65 2.50 1.87 201628 - 7 9.00 17.51 2.48 1.86 211567 - 8 10.40 19.17 2.47 1.85 218976 - 9 11.80 20.91 2.45 1.84 225983 - 10 13.20 22.71 2.43 1.82 232668 - 11 14.60 24.60 2.39 1.80 239095 - 12 13.30 26.31 2.35 1.76 243144 - 13 9.98 27.66 2.30 1.73 243551 - 14 6.65 29.07 2.24 1.68 243998 - 15 3.33 30.29 ' 2.22 1.67 244345 - 16 0.00 31.81 2.15 1.61 244880 - STRAND PATTERN DESCRIPTION - STANDARD Distance Active Passive Strand Pattern Section from tip (stressed) (dormant) Active Passive --------------------------------------------------------------------------- (ft) Qty Qty Qty-\(in) Qty-\(in) 0 0.0 4 0 4-7/16 - 1 1.8 4 0 4-7/16 - 2 3.5 4 0 4-7/16 - 3 5.3 4 0 4-7/16 - 4 7.0 4 0 4-7/16 - 5 8.8 4 0 4-7/16 - 6 10.5 4 0 4-7/16 - 7 12.3 4 0 4-7/16 - 8 14.0 4 0 4-7/16 - 9 15.8 4 0 4-7/16 - 10 17.5 4 0 4-7/16 - 11 19.3 4 0 4-7/16 - 12 21.0 4 0 4-7/16 - 13 22.8 4 0 4-7/16 - 14 24.5 4 0 4-7/16 - 15 26.3 4 0 4-7/16 - 16 28.0 4 0 4-7/16 - 45288 SHEET_OF_ REQUIREMENTS (fy = 60 ksi) -------------------------SHEAR Distance ------------------------------------------------- Shear Reinforcement Section from tip Vu/.85 Vc Vs spiral Av (in2) Vc/2 Avmin # --------------------------------------------------------------------------- (ft) (kips) (kips) (kips) @ 126 @ 86 @ 66 (kips) (in2/ft) 0 0.0 0.0 3.1 - 0.000 0.000 0.000 1.5 0.050 1 1.8 0.9 8.4 - 0.000 0.'000 0.000 4.2 0.053 2 3.5 0.9 3.8 - 0.000 0.000 0.000 1.9 0.056 3 5.3 0.9 4.2 - 0.000 0.000 0.000 2.1 0.059 4 7.0 0.9 4.7 - 0.000 0.000 0.000 2.3 0.061 5 8.8 0.9 5.1 - 0.000 0.000 0.000 2.6 0.064 6 10.5 0.9 5.6 _ - 0.000 0.000 0.000 2.8 0.067 7 12.3 0.9 6.0 - 0.000 0.000 0.000 3.0 0.070 8 14.0 0.9 6.5 - 0.000 0.000 0.000 3.3 0.073 9 15.8 0.9 7.1 - 0.000 0.000 0.000 3.5 0.076 10 17.5 0.9 7.6 - 0.000 0.000 0.000 3.8 0.078 11 19.3 0.9 8.2 - 0.000 0.000 0.000 4.1 0.081 12 21.0 2.2 8.7 - 0.000 0.000 0.000 4.4 0.084 13 22.8 2.2 9.3 - 0.000 0.000 0.000 4.7 0.087 14 24.5 2.2 10.7 - 0.000 0.000 0.000 5.3 0.090 15 26.3 2.2 20.1 - 0.000 0.000 0.000 10.0 0.093 16 28.0 2.2 28.2 - 0.000 0.000 0.000 14.1 0.095 ------------------- Section Elastic # ------------------- Shortening 0 - 1 11.06 2 10.04 3 9.15 4 8.37 5 7.69 6 7.09 7 6.55 8 6.07 9 5.64 10 5.26 11 4.91 12 4.59 13 4.31 14 4.05 15 3.81 16 3.59 PRESTRESS LOSSES (%) ----------------------------------------------- Shrinkage Creep Steel Total Relaxation Losses ----------------------------------------------- 9.25 13.11 0.55 33.96 9.19 12.03 0.55' 31.82 9.13 11.07 0.56 29.91 9.08 10.20 0.56 28.21 9.02 9.41 0.57 26.69 8.96 8.71 0.57 25.33 8.90 8.07 0.57 24.09 8.85 7.49 0.58 22.98 8.79 6.96 0.58 21.97 8.73 6.48 0.58 21.06 8.68 6.05 0.59 20.22 8.62 5.65 0.59 19.45 8.56 5.29 0.59 18.75 8.51 4.96 0.59 18.10 8.45 4.65 0.59 17.50 8.39 4.37 0.59 16.95 Gs, Carlton Square HVAC Load Analysis for Carlton Plaza US 1 & Kitterman Rd Port St. Lucie, FL VA COMMORCIAL HVAC LOADS V Prepared By: Eric J. Svoboda, PE Garrison Engineering 4826 South US Hwy 1 Fort Pierce, FL 34982 772-466-2500 Friday, July 06, 2007 "M 00 IMP W W N101H W I", Building peaks in August at 3pm. Wall 10,887 34,131 10.96 �0 17,450 17,450 2.78 Glass 2,085 75,685 24.31 0 75,570 75,570 12.06 Floor Slab 1,081 22,117 7.10 0 0 0 0.00 Skin Loads 181,346 58.25 0 122,686 122,686 19.57 Lighting 49,912 0 0.00 0 170,307 170,367 27.17 Equipment 12,478 0 0.00 0 42,577 42,577 6.79 People 166 0 0.00 33,275 41,593 74,868 11.94 Partition 0 0 0.00 0 0 0 0.00 Cool. Prot. 0 0 0.00 0 0 0 0.00 Heat. Pret. 0 0 0.00 0 0 0 0.00 Cool. Vent. 3,650 0 0.00 151,515 60,171 211,686 33.77 Heat. Vent. 3,650 129,969 41.75 0 0 0 0.00 Cool. Infil. 0 0 0.00 0 0 0 0.00 Heat. Infil. 0 0 6.00 0 0 0 0.00 Draw-Thru Fan 0 0 0.00 0 4,672 4,672 0.75 Blow-Thru Fan 0 0 0.00 0 0 0 0.00 Reserve Cap. 0 0 0.00 0 0 0 0.00 Rehedt Cap. 0 0 0.00 0 0 0 0.00 Supply Duct 0 0 0.00 0 0 0 0.00 Retum Duct 0 0 0.00 0 0 0 0.00 Misc. Supply 0 0 0.00 0 0 0 0.00 .7 Misc. Return 0 0 0.00 0 0 0 0.00 Building Totals 311,315 100.00 184,790 442,006 626,796 100.00. % Lea I Ih M, MM-N E- Ventilation 129,969 41.75 151,515 60,171 211,686 33.77 Infiltration 0 0.00 0 0 0 0.00- Pretreated Air 0 0.00 0 0 0 0.00 Zone Loads 181,346 58.25 33,275 377,163 410,438 65.48 Plenum Loads 0 0.00 0 0 0 0.00 Fan & Duct Loads 0 0.00 0 4,672 4,672 0.75 Building Totals 311,315 100.00 184,790 442,006 626,796 100.00 Total Building Supply Air (based on a 200 TD): 19,518 CFM Total Building Vent. Air (18.70% of Supply): 3,650 CFM Total Conditioned Air Space: 24,956 Sq.ft Supply Air Per Unit Area: 0.7821 CFM/Sq.ft Area Per Cooling Capacity: 477.7824 Sq.ftITon Cooling Capacity Per Area: 0.0021 Tons/Sq.ft Heating Capacity Per Area: 12.47 Btuh/Sq.ft Total Heating Required With Outside Air: 311,315 Btuh Total Cooling Required With Outside Air: 52.23 Tons W'.\06 PROJECTS\06002-07 Lexington Square\CalculationsWech\Cariton Plaza.CHV Friday, July 06, 2007, 11:40.AM CljpBc Ftilrcolnr»erc10IIIracLoadeca�cuiatlo Program ,:�* r ,s y �� E�noS`oftw4reg elopment,�nc, eFnrtJ5er0�nFl��1n„y `���r�,-s� i A►i~ Har►d►er #1Summary Loatls ° r ; ° ; " Y`a °" " 'a e boa2.t t^Las SenOf W LatGainx�yF,�i o air: �e&i�Tme '� Peopi �gt/l �CI((� � "mS�Ezh � Re $iRepGFN�. VON `f'. J A f„apm•*+ rF kS P,.`i '', '.§g syM3w.� tag.+7,R' yp$r n pY 3 n3v,"h y.' }'`P. °e.'.., b. �Y, ill. 1 Retail 1,000 12,024 '21,276 1,333 Direct Direct 8am August 7 557 979 0 150 150 10,000 0.56 0.98 0 150 150 Zone Peak Totals: 1,000 12,024 21,276 1,333 Total Zones: 1 7 557 979 0 150 150 Unique Zones: 1 10,000 0.56 0.98 0 ' 150 150 Xl v �+ t. 4' W:\06 PROJECTS\06002-07 Lexington Square\CalculationsWlech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM Ghvc ,tI Commercl "HVACaLoade CaleW 3R rCarrlsogfnee" 4 ° ;* x - Ilte"So ara a elopmentrOa g{ ertotSgare r* w, . a.. 6 "� Pa e 4 qrr Handler #1 Total, Loaa1 Sum►�rar� Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.09 HP Fan Input: 0%, motor and fan efficiency with 0 in. water across the fan 9 Sensible Heat Ratio: 0.94 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: gam in August. Outdoor Conditions: 79° DB, 76° WB, 127.93 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 8am is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 21,276. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 12,024 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 17,366 Btuh Heating Supply Air: 12,024 / (.999 X 1.08 X 20) = 557 CFM Winter Vent Outside Air (26.9% of supply) = 150 CFM Zone space sensible gain: 21,234 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 234 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 21,468 Btuh Cooling Supply Air: 21,510 / (.999 X 1.1 X 20) = 979 CFM Summer Vent Outside Air (15.3% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 659 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 659 Btuh Total sensible gain on air handling system: 22,128 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,758 Btuh . Total latent gain on air handling system: 8,091 Btuh Total system sensible and latent gain: 30,219 Btuh Total Air Handler Supply Air (based on a 200 TD): 979 CFM Total Air Handler Vent. Air (15.33% of Supply): 150 CFM. Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.9786 CFM/Sq.ft Area Per Cooling Capacity: 397.1015 Sq.ft/Ton Cooling Capacity Per Area: 0.0025 Tans/Sq.ft Heating Capacity Per Area: 17.37 Btuh/Sq.ft Total Heating Required With Outside Air: 17,366 Btuh Total Cooling Required With Outside Air: 2.52 Tons 4 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM i? Retail -1,000 7,388 Barn August 7 342 10,000 0.34 Zone Peak Totals: 1,000 7,3B8 Total Zones: 1 7 342 Unique Zones: 1 10,000 0.34 20,184 1,333 Direct 928 0 150 0.93 0 150 20,184 1,333 928 0 150 0.93 0 150 Direct 150 150 150 150 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mach\Carlton Plaza.CHV' Friday, July 06, 2007, 11:40 AM Supply Air Fan: Draw-Thru with program estimated horsepower of 0.09 HP Fan Input: 0% motor and fan efficiency with 0 in: water across the fan Sensible Heat Ratio: 0.94 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 9am in August. Outdoor Conditions: 79° DB, 76° WB, 127.93 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at Barn is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 20,184. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM - Outside Air sensible loss: 5,341 Stuh 150 CFM - Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zone space sensible gain: 19,940 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 222 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 20,162 Btuh Cooling Supply Air: 20,407 / (.999 X 1.1 X 20) = 928 CFM Summer Vent Outside Air (16.2% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 659 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 659 Btuh Total sensible gain on air handling system: 20,822 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,758 Btuh Total latent gain on air handling system: 8,091 Btuh Total system sensible and latent gain: 28,913 Btuh i oiai Air Hanaier Supply Air (based on a 209 TD): 928 CFM Total Air Handler Vent. Air (16.169/o of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.9284 CFM/Sq.ft Area Per Cooling Capacity: 415.0391 Sq.ftITon Cooling Capacity Per Area: 0.0024 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.41 Tons W:\06 PROJECTS\06002-07 Lexington Square\CalculationsWech\Cadton Plaza.CHV -- . Friday, July 06, 2007, 11:40 AM el- { 3�`i�/aJli$Gfa'yVT-'��Mj.[+jyY(�j h4f Y?-k' 'net ]];'� St N'Y...r`�R 3 Retail 1,000 7,388 20,184 1,333 Direct Direct 8am August 7 342 928 0 150 150 10,000 0.34 0.93 0 150 150 Zone Peak Totals: 1,000 7,388 20,184 1,333 Total Zones: 1 7 342 928 0 150 150 Unique Zones: 1 10,000 0.34 0.93 0 150 150 W:\06 PROJECTS\06002-07 Lepngton Square\Calculations\ Mech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM Supply Air Fan: Draw-Thru with program estimated horsepower of 0.09 HP Fan Input: 0% motor and fan efficiency with 0 in, water across the fan Sensible Heat Ratio: 0.94 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 9am in August. Outdoor Conditions: 79` DB, 76° WB, 127.93 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 8am is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 20,184. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8%, of supply) = 150 CFM Zone space sensible gain: 19,940 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 222 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 20,162 Btuh Cooling Supply Air: 20,407 / (.999 X 1.1 X 20) = 928 CFM Summer Vent Outside Air (16.2% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 659 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 659 Btuh Total sensible gain on air handling system: 20,822 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,758 Btuh Total latent gain on air handling system: 8,091 Btuh Total system sensible and latent gain: 28,913 Btuh UM �u nanmer auppiy Air (aasea on a zu- I u): 926 GFM Total Air Handler Vent. Air (16.16% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.9284 CFM/Sq.ft Area Per Cooling Capacity: 415.0391 Sq.ft/fon Cooling Capacity Per Area: 0.0024 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.41 Tons WA06 PROJECTS\06002-07 Lebngton Square\Calculations\Mech\Carlton PIaza.CHV Friday, July 06, 2007,11:40 AM 4 Retail 1,000 7,388 20,184 1,333 Direct Direct Sam August 7 342 928 0 150 150 10,000 0.34 0.93 0 150 150 Zone Peak Totals: 1,000 7,388 20,184 1,333 Total Zones: 1 7 342 928 0 150 150 Unique Zones: 1 10,000 0.34 0.93 0 150 150 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton.Plaza.CHV. _ Friday, July06, 2007, 11:40 AM, fx° V 0 4 0 c .. �n'PP u� E feB ere s :z .���"S�$'i,,�" Sri :qa� ,r�¢ #` ✓aim � Y.�' ���t�fi�s # Air Hartdl er #4 Tofaf Load Summary .... r =r Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.09 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.94 This system occurs 1 time(s) in the building. --- Air System Peak Time: 9am in August. Outdoor Conditions: 79° DB, 76° WB, 127.93 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at Elam is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 20,184. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air, sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zone space sensible gain: 19,940 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 222 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 20,162 Btuh Cooling Supply Air: 20,407 / (.999 X 1.1 X 20) = 928 CFM , Summer Vent Outside Air (16.2% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 659 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 659 Btuh Total sensible gain on air handling system: 20,822 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,758 Btuh Total latent gain on air handling system: 8,091 Btuh Total system sensible and latent gain: 28,913 Btuh � wtdl i� '✓+{ �''t` �f`9�;p. � � fA Yty .y 5 x � �+..?..'�;'k� �'L. � � i `4.'�'�F,:3A� 4-R,�yiS�y- �,i..^�` � xa ���£�z. . &S.i'y' Total Air Handler Supply Air (based on a 20' TD): 928 CFM Total Air Handler Vent. Air (16.16% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.9284 CFM/Sq.ft Area Per Cooling Capacity: 415.0391 Sq.ft/Ton Cooling Capacity Per Area: 0.0024 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.41 Tons WA06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\CarltonPIaza.CHV Friday, July 06, 2007, 11:40 AM 5 Retail 1,000 7,388 20,184 -1,333 Direct Direct 8am August 7 342 928 0 150 150 10,000 0.34 0.93 0 150 150 Zone Peak Totals: 1,000 7,388 20,184 1,333 Total Zones: 1 7 342 928 0 150 150 Unique Zones: 1 10,000 0.34 0.93 0 150 150 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza:CHV - Friday, July 06,.2007, 11:40 AM x V1 {4 M l tPN 5�i � M ¢ �a, Qgg� c Q 8 { Kw. Ad<Bh A� • C'�IG. A►r Wa►�fler�#,5 To#al'toad Summery ' ", ' _ ," � 4 ` x -; �:.,,.. ° �' �' � , .� Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.09 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.94 ---This system occurs 1 time(s) in the building. --- Air System Peak Time: 9am in August. Outdoor Conditions: 79° DB, 76° WB, 127.93 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at Elam is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 20,184. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM . Zone space sensible gain: 19,940 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 222 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain onsupply side of coil: 20,162 Btuh Cooling Supply Air: 20,407 / (.999 X 1.1 X 20) = 928 CFM Summer Vent Outside Air (16.2% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 659 Btuh__ _ 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 659 Btuh Total sensible gain on air handling system: 20,822 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,758 Btuh Total latent gain on air handling system: 8,091 Btuh Total system sensible and latent gain: 28,913 Btuh .._ y y^^;y S°A#... BS s.�' Xn +Y.{ va.. E a�i':" Z..9i .. If R r' 2 "44'Y4 :, v #` WN�'v Total Air Handler Supply Air (based on a 20' TD): 928 CFM Total Air Handler Vent. Air (16.16% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.9284 CFM/Sq.ft Area Per Cooling Capacity: 415.0391 Sq.ft/Ton Cooling Capacity Per Area: 0.0024 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.41 Tons W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM 6 Retail 1,000 7,388 20,184 1,333 Direct Direct Elam August - 7 342 .. 928 0 150 150 10,000 0.34 0.93 0 150 150 Zone Peak Totals: 1,000 7,388 20,184 1,333 Total Zones: 1 7 342 928 0 150 150 Unique Zones: 1 10,000 0.34 0.93 0 150 150 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton PlamCHV6 Friday, July 06, 2007, 11:40 AM trvac IF¢omme ► tiVAO Loa l:e►cula gpA � gr � � , � ,� v,�: ; �= EIItdSo ere e►op�enki�c sF`btler`ce?fiL�"Jr�9B v� �r��'� . �' �,?r . . ,z . '� rf�i' •k �' `. , .max.. "_ ,��a Pa` e'�ri. Air Handler Description: Constant Volume -Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.09 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.94 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 9am in August. Outdoor Conditions: 79° DB, 76° WB, 127.93 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at Sam is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 20,184. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zone space sensible gain: 19,940 Btuh Infiltration sensible gain: . 0 Btuh Draw-thru fan sensible gain: 222 Btuh :Supply duct sensible gain: 0 Btuh ,Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 20,162 Btuh "Cooling Supply Air: 20,407 / (.999 X 1.1 X 20) = 928 CFM ;Summer Vent Outside Air (16.2% of supply) = 150 CFM `Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 659 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 659 Btuh Total sensible gain on air handling system: 20,822 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,758 Btuh Total latent gain on air handling system: 8,091 Btuh Total system sensible and latent gain: 28,913 Btuh .,. , Total Air Handler Supply Air (based on a 200 TD): 928 CFM Total Air Handler Vent. Air (16.16% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.9284 CFWSq.ft Area Per Cooling Capacity: 415.0391 Sq.ft/Ton Cooling Capacity Per Area: 0.0024 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.41 Tons W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV - Friday, July 06, 2007, 11:40 AM 7 Retail 1,000 7,388 8am August 7 342 10,000 0.34 Zone Peak Totals: 1,000 7,388 Total Zones: 1 7 342 Unique Zones: 1 10,000 0.34 20,184 1,333 Direct Direct 928 0 150 150 0.93 0 150 150 20,184 1,333 928 0 150 150 0.93 0 150 150 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM ChaS1'9� ® a1 HVAC ! oaiiCele alatlo rogr €mom*" r '. -�' ra � �' �- EIIt4 So $re eveloprryerft f s?t rit S air G� � ��a L orr,Pi&06' F' 9�tjt12 . ,. u . Fi Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.09 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.94 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 9am in August. Outdoor Conditions: 79° DB, 76° WB, 127.93 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 8am is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 20,184. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12;729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zone space sensible gain: 19,940 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 222 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 20,162 Btuh Cooling Supply Air: 20,407 / (.999 X 1.1 X 20) = 928 CFM Summer Vent Outside Air (16.2% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 659 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 659 Btuh Total sensible gain on air handling system: 20,822 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,758 Btuh Total latent gain on air handling system: 8,091 Btuh Total system sensible and latent gain: 28,913 Btuh Total Air Handier Supply Air (based on a 200 TD): 928 CFM Total Air Handler Vent. Air (16.16% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.9284 CFM/Sq.ft Area Per Cooling Capacity: 415.0391 Sq.ft/Ton Cooling Capacity Per Area: 0.0024 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.41 Tons W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Cadton Plaza.CHV Friday, July 06, 2007, 11:40 AM 8 Retail 1,000- 7,388 20,184 1,333 Direct Direct 8am August 7 342 928 0 150 150 10,000 0.34 0.93 0 150 150 Zone Peak Totals: 1,000 7,388 20,184 1,333 Total Zones: 1 7 342 928 0 150 150 Unique Zones: 1 10,000 0.34 0.93 0 150 150 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV:. .. _ - . Friday, July 06, 2007, 11:40 AM Supply Air Fan: Draw-Thru with program estimated horsepower of 0.09 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.94 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 9am in August. Outdoor Conditions: 79° DB, 76° WB, 127.93 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at Sam is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 20,184. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss:. 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zane space sensible gain: 19,940 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 222 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 20,162 Btuh Cooling Supply Air: 20,407 / (.999 X 1.1 X 20) = 928 CFM Summer Vent Outside Air (16.2% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 659 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 659 Btuh Total sensible gain on air handling system: 20,822 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,758 Btuh Total latent gain on air handling system: 8,091 Btuh Total system sensible and latent gain: 28,913 Btuh i vial nu rianuier bupply Air (oased on a zu- I u): yLtf UFM Total Air Handler Vent. Air (16.16% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.9284 CFM/Sq.ft Area Per Cooling Capacity: 415.0391 Sq.ft/Ton Cooling Capacity Per Area: 0.0024 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.41 Tons W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV , . Friday, July 06, 2007, 11:40 AM Chvacf Full mmerclaG VAC Loada',Cafcufg�rr��oit rogram =i FF� F l ltte So Davetopmant nc' T..xxyt } vz'zk- 'v �-¢ ft$,Qn �n 1 R� „' o x5� „r M5+ FO ,Ief .r�FL349 :.wt�'ikf-s rr��';. 4x3k .i.. n`2'^„j``:n4 4sz?? �`vsr <Nc•:`^t� .,,..�:e"G''`P�$ ..1r #� j• +... e.� rc r r .r h -v l..r � v' a r�} Zn Deanpfmr ' 3 Aiea g Htg Loss` 5e 'Gelp Lat`Galn NCH �rA" ° yy�t9' y 'd`"'re 74s°° " '5`` p4 �S ��epR� ItnYe, � �9 Retail 1,000 7,388 20,184 1,333 Direct Direct Bam August 7 342 928 0 150 150 10,000 0.34 0.93 0 150 150 Zone Peak Totals: 1,000 7,388 20,184 1,333 Total Zones: 1 7 342 928 0 150 150 Unique Zones: 1 10,000 0.34 0.93 0 150 150 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM ' Supply Air Fan: Draw-Thru with program estimated horsepower of 0.09 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.94 --- This system occurs 1 time(s) in the.building. --- Air System Peak Time: 9am in August. Outdoor Conditions: 79- DB, 76° WB, 127.93 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 8am is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 20,184. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 -Btuh Return Plenum sensible loss: 0 Btuh - Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zone space sensible gain: 19,940 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 222 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 20,162 Btuh Cooling Supply Air: 20,407 / (.999 X 1.1 X 20) = 928 CFM Summer Vent Outside Air (16.2% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 659 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 659 Btuh Total sensible gain on air handling system: 20,822 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,758 Btuh Total latent gain on air handling system: 8,091 Btuh Total system sensible and latent gain: 28,913 Btuh V LM M11 nanwer ouppry Air taasea on a zu- I u): 928 OFM Total Air Handler Vent. Air (16.16% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.9284 CFM/Sq.ft Area Per Cooling Capacity: 415.0391 Sq.fVTon Cooling Capacity Per Area: 0.0024 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2AI Tons WA06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV - Friday, July 06, 2007, 11:40 AM ]0 Retail10 1,000 7,388 20,184 - 1,333 Direct Direct 8am August 7 342 928 0 150 150 10,000 0.34 0.93 0 150 150 Zone Peak Totals: 1,000 7,388 20,184 1,333 Total Zones: 1 7" 342 928 0 150 150 Unique Zones: 1 10,000 0.34 0.93 0 150 150 W:\06 PROJECTS\06002-07 Lexington Square\CalculationsNMech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM ' rayEn11�1nei VAS`` aelbutffiIbh'f� of �p itemengtr^I�rc tFortPiece�ihL94s6g2 s- A �r,�'Hand►er#D.,Total,LoadSumm� .::, ti on 'h3 ,E4 F���>� ����`,';a,_�_�� �:,.,.. _ �;,'„h.K� ,_ ,:� Air Handler Description: Constant Volume - Proportion Supply'Air Fan: Draw-Thru with program estimated horsepower of 0.09 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.94 --- This system occurs 1 time(s) in the building. •- Air System Peak Time: 9am in August. Outdoor Conditions: 79° DB, 76° WB, 127.93 grains . Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 8am is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 20,184. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zone space sensible gain: 19,940 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 222 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 20,162 Btuh Cooling Supply Air: 20,407 / (.999 X 1.1 X 20) = 928 CFM Summer Vent Outside Air (16.2% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 659 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 659 Btuh Total sensible gain on air handling system: 20,822 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,758 Btuh Total latent gain on air handling system: 8,091 Btuh system sensible and latent gain: 28,913 Btuh fTotal yp. Total Air Handler Supply Air (based on a 200 TD): 928 CFM Total Air Handler Vent. Air (16.16% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.9284 CFM/Sq.ft Area Per Cooling Capacity: 415.0391 Sq.fUfon Cooling Capacity Per Area: 0.0024 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.41 Tons W:\06 PROJECTS\06002-07 Lepngton Square\Calculations\Mech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM �+s.?a'� A►r f#anller #i Summary +1. y{�y(i�:. Y $+�+L'i 4 Vas F �[�4 •i�-4 }g3',J71iu 011- "BY , '$G"A. y 4V �M J* L i `'" •2 1{.� v° kilYR lki{ x "F ieiN /Xl{. 11 Retail11 1,000 7,388 20,184 1,333 Direct Direct Sam August 7 342 928 0 150 150 10,000 0.34 0.93 0 150 150 Zone Peak Totals. 1,000 7,388 20,184 1,333 Total Zones: 1 7 342 928 0 150 150 Unique Zones: 1 10,000 0.34 0.93 0 150 150 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Calton Plaza.CHV' Friday, July 06, 2007, 11:40 AM eiis 6F`Funl¢�Gorlat ACoadSC I�ulatl4nproltH� ° ." rEIf<eS�Qnmet8< tFbtt�Pler 982 �H�s s v�5�a��.�at m:5 A�r,Hnd/erfl Tofal;Loagl.Summary,, , ,;, E F Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.09 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.94 --- This system occurs 14ime(s) in the building. --- Air System Peak Time: 9am in August. Outdoor Conditions: 79° DB, 76° WB, 127.93 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at Barn is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 20,184. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: . 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zone space sensible gain: 19,940 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 222 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 20,162 Btuh Cooling Supply:Air: 20,407 / (.999 X 1.1 X 20) = 928 CFM Summer Vent Outside Air (16.2% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 659 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 659 Btuh Total sensible gain on air handling system: 20,822 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,758 Btuh Total latent gain on air handling system: 8,091 Btuh Total system sensible and latent gain: 28,913 Btuh h� M dLI Total Air Handler Supply Air (based on a 200 TD): 928 CFM Total Air Handler Vent. Air (16.16% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.9284 CFM/Sq.ft Area Per Cooling Capacity: 415.0391 Sq.fUfon Cooling Capacity Per Area: 0.0024 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.41 Tons W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM 12 Retail12 1,000 7,388 20,184 1,333 Direct Direct Bam August 7 342 928 0 150 150 10,000 0.34 0.93 0 150 150 Zone Peak Totals: 1,000 7,388 20,184 1,333 Total Zones: 1 7 342 928 0 150 150 Unique Zones: 1 10,000 0.34 0.93 0 150 150 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza:CHV. - : 'Friday, July 06, 2007, 11:40 AM thva fUl Or 1 ep 11V7lO- o d C IOulbl[o tTOgram nv 9 ns �il8 t # <,T: AEI aS6tftv AenO! pi�ie0tiln '„, �€ Earlton Sq�na, Mile!v� ,1� , �1ofiPerca34 r � .� .a'` �a �� Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.09 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.94 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 9am in August. Outdoor Conditions: 79° DB, 76° WB, 127.93 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 8am is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 20,184. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zone space sensible gain: 19,940 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 222 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 20,162 Btuh Cooling Supply Air: 20,407 / (.999 X 1.1 X 20) = 928 CFM' Summer Vent Outside Air (16.2% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 659 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 659 Btuh Total sensible gain on air handling system: 20,822 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,758 Btuh Total latent gain on air handling system: 8,091 Btuh Total system and latent. gain: 28,913 Btuh ysensible � .j �0 iSwet... la ^ a: emu' �. A v'#S�" =5i`. .q. •..� Y Y�'- ,6iS� _ .ti l Total Air Handler Supply Air (based on a 200 TD): 928 CFM Total Air Handler Vent. Air (16.16% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.9284 CFM/Sq.ft Area Per Cooling Capacity: 415.0391 Sq.WTon Cooling Capacity Per Area: 0.0024 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.41 Tons W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\CarltomPlaza.CHV - Friday, July 06, 2007, 11:40 AM ,IV nciau 10-w 4,700 ZL,OUI Oy,tl48 O,V/O Vllecl vu vci 6pm August 30 1,047 2,620 0 600 600 45,560 0.23 0.58 0 600 600 Zone Peak Totals: 4,556 22,601 59,848 6,075 Total Zones: 1 30 1,047 2,620, 0 600 600 Unique Zones: 1 45,560 0.23 0.58 0 600 600 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV . Friday, July 06, 2007, 11:40 AM hvqc pll�Core 1 k11/ASA"'Obd alit ICI f b4tatll6` rP � c � Eilta 9 am-P Yelop,�e tY3nrY, k a 1x f� �, CarlIt DSO TO e FL 98 zt ,xu �iM"�w'- .$ d28' Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.25 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.91 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 5pm in August. Outdoor Conditions: 89° DB, 78° WB, 128.26 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 6pm is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 59,848. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 22,601 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 21,365 Btuh 600 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 43,965 Btuh Heating Supply Air: 22,601 / (.999 X 1.08 X 20) = 1,047 CFM Winter Vent Outside Air (57.3% of supply) = 600 CFM Zone space sensible gain: 59,732 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 627 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 60,360 Btuh Cooling Supply Air: 60,475 / (.999 X 1.1 X 21) = 2,620 CFM Summer Vent Outside Air (22.9% of supply) = 600 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 8,572 Btuh 600 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 8,572 Btuh Total sensible gain on air handling system: 68,932 Btuh Zone space latent gain: 6,075 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 26,246 Btuh Total latent gain on air handling system: 32,320 Btuh Total system sensible and latent gain: 101,252 Btuh y< ._ 2. 1,_�� .. Total Air Handler Supply Air (based on a 21 ° TD): 2,620 CFM Total Air Handler Vent. Air (22.90% of Supply): 600 CFM Total Conditioned Air Space: 4,556 Sq.ft Supply Air Per Unit Area: 0.5751 CFM/Sq.ft Area Per Cooling Capacity: 539.9598 Sq.ftlron Cooling Capacity Per Area: 0.6019 Tons/Sq.ft Heating Capacity Per Area: 9.65 Btuh/Sq.ft Total Heating Required With Outside Air: 43,965 Stuh Total Cooling Required With Outside Air: 8.44 Tons W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV . Friday, July 06, 2007, 11:40 AM 19r': A�r,Hand/e"r #�4 summary Loads.... ` t ��w.. , x, ... .. _._. , _ ,r ..> ,u vNx- t.fi ez`ii'✓xa f 'mi`n., a + r r€. " �_ `m �t fig. yy; ''3tfj39^.y�yy� sib rr xJ- ' t x i�M�p� �{117aa y� q� 1*SLtia f`i }�- ��f z' .d .:'�,.{A 14 Retail15 1,000 7,388 15,303 1,333 Direct Direct 6pm August 7 342 670 0 150 150 10,000 0.34 0.67 0 150 150 Zone Peak Totals: 1,000 7,388 15,303 1,333 Total Zones: 1 7 . 342 670 0 150 150 Unique Zones: 1 10,000 0.34 0.67 0 150 150 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM fi� r tr oI o k Fitts` oar q R ��L;((((�� iFr'ry($j 'fd"M1 d) 1 2rc. rC4",1 -IN 4 Ai►r'Handtex #14.Tota! Laad,Sumrr�a_ry.,, . ..'.. Air Handler Description: Constant Volume - Proportion = Supply Air Fan: Draw-Thru with program estimated horsepower of 0.06 HP ' Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.92 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 5pm in August. Outdoor Conditions: 89° DB, 78° WB, 128.26 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 6pm is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 15,303. Summer: Ventilation controls outside air, ---- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM .Zone space sensible gain: 15,057 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 160 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 15,217 Btuh Cooling Supply Air: 15,463 / (.999 X 1.1 X 21) = 670 CFM Summer Vent Outside Air (22.4% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 2,143 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 2,143 Btuh Total sensible gain on air handling system: 17,360 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,561 Btuh Total latent gain on air handling system: 7,895 Btuh Total system sensible and latent gain: 25,255 Btuh VON Total Air Handler Supply Air (based on a 21 ° TD): 670 CFM Total Air Handler Vent. Air (22.39% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.6700 CFM/Sq.ft Area Per Cooling Capacity: 475.1511 Sq.ff/Ton Cooling Capacity Per Area: 0.0021 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.10 Tons W A06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza:CHV Friday, July 06, 2007, 11:40 AM k �jIR§6+x�` c *f' i �� °n.�<�.s $"t"'Z ""'fr`a'xx'- #Y•'f�" :Arr Hanalh�r yy#�S,Summary f ` � n 4td .p',�r".`er#£ +i`'s` p -# x x .; �'1#�1x "-"'�.f¢ # y�.''�%?"4 r r ty..'a ksFTnLraPe`t"v Y g' -t,v„, r=. ..��2 .,,,�c ,s „r c t7 -.�br-.n✓^3ti ` T .� I... t,h-f�3�,w �n M{' -.15 Retail16 1,000 7,388 15,303 1,333 Direct Direct 6pm August 7 342 670 0 150 150 10,000 0.34 0.67 0 150 150 Zone Peak Totals: 1,000 7,388 15,303 1,333 Total Zones: 1 7 342 670 0 150 150 Unique Zones: 1 10,000 0.34 0.67 0 150 150 W.V6 PROJECTS\06002-07 Lexington Square\Calculations\Meth\Carlton Plaza.CHV .. : , - Friday, July 06, 2007, 11:40 AM t I+rap. FUIfoft",ft }t AG Load§zCatcu131f `rt P� IIte,So arepeYopmapylnc e A�r,Hanpller #�5�,_T_ ofal�Load�Summary� r �'k3 �7�� � � � r�INA, Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.06 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.92 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 5pm in August. Outdoor Conditions: 89° DB, 78° WB, 128.26 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 6pm is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 15,303. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zone space sensible gain: 15,057 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 160 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 15,217 Btuh Cooling Supply Air: 15,463 / (.999 X 1.1 X 21) = 670 CFM Summer Vent Outside Air (22.4% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 2,143 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 2,143 Btuh Total sensible gain on air handling system: 17,360 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,561 Btuh Total latent gain on air handling system: 7,895 Btuh Total system sensible and latent gain: 25,255 Btuh Total Air Handler Supply Air (based on a 21 ° TD): 670 CFM Total Air Handler Vent. Air (22.39% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.6700 CFM/Sq.ft Area Per Cooling Capacity: 475.1511 Sq.ft/Ton Cooling Capacity Per Area: 0.0021 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.10 Tons ay _ WA06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM f .16 Retail17 1,000. 7,388 15,303 1,333 Direct Direct 6pm August 7 342 670 0 150 150 10,000 0.34 0.67 0 150 150 Zone Peak Totals: 1,000 7,388 15,303 1,333 Total Zones: 1 7 342 670 0 150 150 Unique Zones: 1 10,000 0.34 0.67 0 150 150 r 4 WA06 PROJECTS\06002-07 LeAnoton Square\Calculations\Mach\Carlton Plaza!CHV - Friday, July 06, 2007, 11:40 AM 1a�7ir,6�1gitlSQey AC'Laa. a Caleulpn ) r�� 4 3 E�Itm;So �D etbp q p i 1'a 5 .'icy nF't x! yTArF":c'f Y f h 4 {'r 1Y 5 Air Hantlle16 Totalrl oad Summary, Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.06 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.92 This system occurs 1 time(s) in the building. --- Air System Peak Time: 5pm in August. Outdoor Conditions: 89° DB, 78° WB, 128.26 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 6pm is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 15,303. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zone space sensible gain: 15,057 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 160 Btuh Supply duct sensible gain: 0 ' Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 15,217 Btuh Cooling Supply Air: 15,463 / (.999 X 1.1 X 21) = 670 CFM Summer Vent Outside Air (22.4% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 2,143 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 2,143 Btuh Total sensible gain on air handling system: 17,360 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,561 Btuh Total latent gain on air handling system: 7,895 Btuh Total system sensible and latent gain: 25,255 Btuh Total Air Handler Supply Air (based on a 21 ° TD): 670 CFM Total Air Handler Vent. Air (22.39% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.6700 CFM/Sq.ft Area Per Cooling Capacity: 475.1511 Sq.ft/Ton Cooling Capacity Per Area: 0.0021 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.10 Tons W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM ,k'OI�'�16I'�� 6���e�"G'.� �3 n1'x�`�p'4,Y '.t "r�� ��� �5���., �'�#3�`il� ,5. +£ei �a73Ch���°y� �M !p•��' h� �t 17 Retail18 1,000 7,388 15,303 1,333 Direct Direct 6pm August 7 342 670 0 150 150 10,000 0.34 0.67 0 150 150 Zone Peak Totals: 1,000 : 7,388 15,303 1,333 Total Zones: 1 7 342 670 0 150 150 Unique Zones: 1 10,000 0.34 0.67 0 150 150 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV - Friday, July 06, 2007, 11:40 AM gh�vo full Caifsm1= AC t'�ada Gn cu{a�tion gram aGarrgr�aet� �� p"rt iroeFl�a�34i£i2"b �s. : Etlte So ere ig(pmentt lner * tier to qua e f�3�.�' tz'* 3'`e,8ttr Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.06 HP Fan Input: 0% motor and fan efficiency with 0 in: water across the fan Sensible Heat Ratio: 0.92 ---This system occurs 1 time(s) in the building. --- Air System Peak Time: 5pm in August. Outdoor Conditions: 89° DB, 78' WB, 128.26 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 6pm is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 15,303. Summer: Ventilation controls outside air, ---- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,3B8 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zone space sensible gain: 15,057 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 160 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 15,217 Btuh Cooling Supply Air: 15,463 / (.999 X 1.1 X 21) = 670 CFM Summer Vent Outside Air (22.4% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 2,143 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 2,143 Btuh Total sensible gain on air handling system: 17,360 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,561 Btuh Total latent gain on air handling system: 7,895 Btuh Total system sensible and latent gain: 25,255 Btuh Total Air Handler Supply Air (based on a 210 TD): 670 CFM Total Air Handler Vent. Air (22.39% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.6700 CFM/Sq.ft Area Per Cooling Capacity: 475.1511 Sq.ft/Ton Cooling Capacity Per Area: 0.0021 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.10 Tons W:\06 PROJECTS\06002-07 Lexington Square\CalculationsWlech\Carlton;Plaza.CHV - Friday, July 06, 2007, 11:40 AM 1.. a ` ). c rc aP G t o�te an`�to k �.. a g. tl eves Rtr� �S.6 A'�r,Hardler#iBSumma bads ..„� pq {>v.. y.�.. s� �141 t w gWCa":yam bs�.; Aye' w. i j tvs� .�_` w x . 5 (} p (y 3+. J(§j��I nn }�.VVy� ��yy,,,� .xii •5� 1+`uyy t1t :. .e'.l7 ..N s*` {ffx�G S:.f �Y 18 Retail19 1,000 7,388 15,303 1,333 Direct Direct 6pm August 7 342 670 0 150 150 10,000 0.34 0.67 0 150 150 -.__ ..----- ---- -_- _ — -- -_ -- — Zone Peak Totals: 1,000 7,388 15,303 1,333 Total Zones: 1 7 342 670 0 150 150 Unique Zones: 1 10,000 0.34 0.67 0 150 150 W-.\06 PROJECTS\06002-07 Lepngton Square\Calculations\Mech\Carlton Plaza.CHV • . . Friday, July 06, 2007, 11:40 AM w oys § A d$ ar o gtaa �p„ BEg'NkEgm�'"y^• r'3.�i-<fM.' z74 I C4v a eh %hc ?m+ '�Ar7�'' "^�'` " ro;..a. `"?'t>.. zw ,��'�rlftln y8r' i�..-�3�+c g .:tn°r,'5„*", l�r Handler#i8 dotal Ldad Summary,., _ 4 Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.06 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.92 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 5pm in August. Outdoor Conditions: 89° DB, 78° WB, 128.26 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 6pm is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 15,303. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM - Zone space sensible gain: 15,057 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 160 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 15,217 Btuh Cooling Supply Air: 15,463 / (.999 X 1.1 X 21) = 670 CFM Summer Vent Outside Air (22.4% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 2,143 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 2,143 Btuh Total sensible gain on air handling system: 17,360 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,561 Btuh Total latent gain on air handling system: 7,895 Btuh Total system sensible and latent gain: 25,255 Btuh Total Air Handler Supply Air (based on a 21 ° TD): 670 CFM Total Air Handler Vent. Air (22.39% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.6700 CFM/Sq.ft Area Per Cooling Capacity: 475.1511 Sq.ft/Ton Cooling Capacity Per Area: 0.0021 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.10 Tons W:\06 PROJECTS\06002-07 Lebngton Square\Calculations\Mech\Carlton Plaza.CHV . Friday, July 06, 2007, 11:40 AM D Q sv EngT'eer0g ' $� ,0rhAkift,''i ' �S �3��,,,1_)P � Ji�'x�y�, 'ilk �� p ,�}r.��/,+� }� � �.L,�' �'4� t� v��•�7('K�� ".'�� j (�� '���:. /y'fF�grvxj st;*',?Ua iY',�;"E1R 19 Retail20 1,000 7,388 15,303 1,333 Direct Direct 6pm August 7 342 670 0 150 150 10,000 0.34 0.67 0 150 150 Zone Peak Totals: 1,000 7,388 15,303 1,333 Total Zones: 1 7 342 670 0 150 150 Unique Zones: 1 10,000 0.34 0.67 0 150 150 W:\06 PROJECTS\06002-07 Lexington Square\CalculationsWech\Carlton PIaza.CHV ' - . - Friday, July 06, 2007, 11:40 AM h n �hG l 'Will apb g e� .. � r1 ."` G 11— Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.06 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat, Ratio: 0.92 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 5pm in August. Outdoor Conditions: 89° DB, 78° WB, 128.26 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 6pm is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 15,303. Summer: Ventilation controls outside air, ----c Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zone space sensible gain: , 15,057 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 160 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 15,217 Btuh Cooling Supply Air: 15,463 / (.999 X 1.1 X 21) = 670 CFM Summer Vent Outside Air (22.4% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 2,143 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 2,143 Btuh Total sensible gain on air handling system: 17,360 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,561 Btuh Total latent gain on air handling system: - 7,895 Btuh Total system sensible and latent gain: 25,255 Btuh p"aagr�.....n & ^ `na Yal.S:'�- sXg13.y e.^.i�ii. 3?.'4i74A'�Tu.n j ^Air Total Air Handler Supply (based on a 21 ° TD): 670 CFM Total Air Handler Vent. Air (22.39% of Supply): 150 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.6700 CFM/Sq.ft Area Per Cooling Capacity: 475.1511 Sq.ft/Ton Cooling Capacity Per Area: 0.0021 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.10 Tons 7 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\CarltonPlaza.CHV Friday, July 06, 2007, 11:40 AM 20 Retail21 1,000 7,388 15,303 1,333 Direct Direct 6pm August 7 342 670 0 150 150 10,000 0.34 0.67 0 150 150 Zone Peak Totals: 1,000 7,388 15,303 1,333 Total Zones: 1 7 342 670 0 150 150 Unique Zones: 1 10,000 0.34 0.67 0 150 150 e 4 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton P.Iaza.CHV .. - . Friday, July 06, 2007, 11:40 AM rC l A dos` a f P p7o y4 $� "z��' °$k����� �'��,.' �'�' �� _ �'�Sy��k������}�� v 3'" ``-Arr �l�nalC�r�2O'Tata/ioad,�Surt►mary ' �.�' ... Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.06 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.92 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 5pm in August. Outdoor Conditions: 89- DB, 78° WB, 128.26 grains Because of the diversity in zone, plenum and ventilation loads, the zone sensible peak time in August at 6pm is different from the total system peak time, hence the air system CFM was computed using a zone sensible load of 15,303. Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 7,388 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 5,341 Btuh 150 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 12,729 Btuh Heating Supply Air: 7,388 / (.999 X 1.08 X 20) = 342 CFM Winter Vent Outside Air (43.8% of supply) = 150 CFM Zone space sensible gain: 15,057 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 160 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 15,217 Btuh Cooling Supply Air: 15,463 / (.999 X 1.1 X 21) = 670 CFM Summer Vent Outside Air (22.4% of supply) = 150 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 2,143 Btuh 150 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 2,143 Btuh Total sensible gain on air handling system: 17,360 Btuh Zone space latent gain: 1,333 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 6,561 Btuh Total latent gain on air handling system: 7,895 Btuh Total and latent gain: 25,255 Btuh {system �sensible y y t 4 Ili �+1t.]d �ry �..{, f'4'-r T-9pFrt. �� y:' ��•^ � iL p�.�yy �.SZ yy\c � .". `x° �' 3a-t � g`Yl'.'.n'L Total Air Handler Supply Air (based on a 21 ° TD): 670 CFM Total Air Handler Vent. Air (22.39% of Supply): 156 CFM Total Conditioned Air Space: 1,000 Sq.ft Supply Air Per Unit Area: 0.6700 CFM/Sq.ft Area Per Cooling Capacity: 475.1511 Sq.fUfon Cooling Capacity Per Area: 0.0021 Tons/Sq.ft Heating Capacity Per Area: 12.73 Btuh/Sq.ft Total Heating Required With Outside Air: 12,729 Btuh Total Cooling Required With Outside Air: 2.10 Tons a W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Calton Plaza:CHV Friday, July 06, 2007, 11:40 AM 21 Retail22 1,400 13,746 23,229 1,867 Direct Direct 3pm August 9 637 1,017 0 200 200 14,000 0.45 0.73 0 200 200 Zone Peak Totals: 1,400 _ 13,746 23,229 1,867 Total Zones: 1 9 637 1,017 0 200 200 Unique Zones: 1 14,000 0.45 0.73 0 200 200 0 W:\06 PROJECTS\06002-07 Lexington Square\CalculationsWlech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM atoaf it€�g' Tx�tLNh ViAYY i$�#+" �c �I' 4 r?� PJi i '.%r i� 1� _. °.{`'`e e.f� 4ir Handler #2'l I ©{BF,LIDL%.- . ,�] Air Handler Description: Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.10 HP ° Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.93 ---This system occurs 1 time(s) in the building. --- Air System Peak Time: 3pm in August. , Outdoor Conditions: 90° DB, 78° WB, 125.80 grains Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 13,746 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 7,122 Btuh 200 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 20,867 Btuh Heating Supply Air: 13,746 / (.999 X 1.08 X 20) = 637 CFM Winter Vent Outside Air (31.4% of supply) = 200 CFM Zone space sensible gain: 23,229 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 243 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 23,473 Btuh Cooling Supply Air: 23,473 / (.999 X 1.1 X 21) = 1,017 CFM Summer Vent Outside Air (19.7%of supply) = 200 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 3,297 Btuh 200 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 3,297 Btuh Total sensible gain on air handling system: 26,770 Btuh Zone space latent gain: 1,867 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 8,302 Btuh Total latent gain on air handling system: 10,169 Btuh Total system sensible and latent gain: 36,939 Btuh ,. _ .., 4 X E1.+.,•. Y' � �N .�,� � ,€-„3 p,y- 5t.�;--iik„� "•i .�t` ay'�.7k*' 6 +.� -`3.t d`*s, ,,y bzt� �:5.h u:.' k2'w`'k Total Air Handler Supply Air (based on a 210 TD): 1,017 CFM Total Air Handler Vent. Air (19.67% of Supply): 200 CFM Total Conditioned Air Space: 1,400 Sq.ft Supply Air Per Unit Area: 0.7264 CFM/Sq.ft Area Per Cooling Capacity: 454.8091 Sq.fVTon Cooling Capacity Per Area: 0.0022 Tons/Sq.ft Heating Capacity Per Area: 14.91 Btuh/Sq.ft Total Heating Required With Outside Air: 20,867 Btuh Total Cooling Required With Outside Air: 3.08 Tons W:\06 PROJECTS\06002-07 Lebngton Square\Calculations\Mech\CarltonPlaza.CHV Friday, July 06, 2007, 11:40 AM Fty c Pu4 . (IVAC^X artaCa�culfi r1:P4 ypp"3t" a�, �#+ }•� � �" aIife D j Ic �"` �� �UW Q� �f �i� $��y IIIbU�r.�"W N'4'k� i i5 }Y i i�„� t�S.�'Y' "eYNM14$ ''"E�'fri }'}r: Z/{one Deta�leyd,Loads (At Zane Peak T��rr�Je�s)°x� t1 >Sy4t !nwpp'�y,,J � ^f 'e£��A�rN,yYy3i��tEEn. ?e- ���`.y�yy., t3�`�E�qq���♦,�} 'N��F� �=x$,.�,�{i�iy�yrt�'`be' V,}i� "�i w`t ��//��fE111 ii Y� �k�"+' J��. s. zln `{ yy9..txH' y xa P�+'N.�t `"�'."`Fr.,.r 33 rri'113' SYi'i'i`kkt'i' tY+ 's)..# y(`✓n3 t?ir,t yo,�xww-a34S'X('+i'Y-... 9{f xTR Roof-1-4-Susp.C-L 1,000 0.50 6.8 0.060 409 1.980 1,980 Wall-1-E-C-D 147 1 11.9 0.095 166 3.135 461 Wall-2-N-C-D 534 1 6.5 0.095 330 3.135 1,674 Wall-3-W-C-D 240 1 15.9 0.095 362 3.135 752 GIs-E-1-90-Tran 72.0 1.000 1 1.040 37 36.300 2,614 0%S-0-WS-Solar 72.0 0.550 220 0.800 6,970 GIs-E-1-90-Tran 21.0 1.000 1 1.040 11 36.300 762 0%S-0-WS-Solar 21.0 0.550 220 0.800 2,033 GIs-N-1-90-Tran 54.0 1.000 1 1.040 28 36.300 1,960 O%S-O-WS-Solar 54.0 0.550 38 0.650 734 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 89 20.460 1,821 Sub -total 21,276 1,333 12,024 Safety factors: +0% +0% +0% Total w/ safety factors: --------- --------- 21,276 1,333 --------- 12,024 Roof-1-4-Susp.C-L 1,000 0.50 6.8 0.060 409 1.980 1,980 Wall-1-E-C-D 147 1 11.9 0.095 166 3.135 461 Wall-2-W-C-D 240 1 15.9 0.095 362 3.135 752 GIs-E-1-90-Tran 72.0 1.000 1 1.040 37 36.300 2,614 0%S-0-WS-Solar 72.0 0.550 220 0.800 6,970 GIs-E-1-90-Tran 21.0 1.000 1 1.040 11 36.300 762 0%S-0-WS-Solar 21.0 0.550 220 0.800 2,033 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 -- -------- Sub-total 20,184 1,333 7,388 Safety factors: +0% +0% +0% Total w/ safety factors: --------- --------- 20,184 1,333 --------- 7,388 Roof-1-4-Susp.C-L 1,000 0.50 6.8 0.060 409 1.980 1,980 Wall-1-E-C-D 147 1 11.9 0.095 166 3.135 461 Wall-2-W-C-D 240 1 15.9 0.095 362 3.135 752 GIs-E-1-90-Tran 72.0 1.000 1 1.040 37 36.300 2,614 b%S-O-WS-Solar 72.0 0.550 220 0.800 6,970 GIs-E-1-90-Tran 21.0 1.000 1 1.040 11 36.300 762 0%S-0-WS-Solar 21.0 0.550 220 0.800 2,033 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Meth\Carlton Plaza.CHV = - Friday, July 06, 2007, 11:40 AM x! Ad she e;iC.tattan`P�ta f i e�� �`� yin `F` w &�oitw r0 �r(gaa t trya� � � '9�#:�k 3n1�� i�.�R •�� b..0 -y{Fy'. 'i. :{ $^ 5119"! -.M� F �N' Y....yy,, YT � � k i.' I� V+�i3 JYy,.i'Nr s XYp�N[.^Y�`✓��h� �-Y1 t/'�Z.�A'' 'F diMl• ,���� ��a y.3 ��`$,�%g ��A : .''S�iYfX she *� � a � �VR �'��� �1'1QA� ��4it# �xei x People-Prof=O 6.7 1.000 . 1,667 1,333 Floor slab 40 20.460 818 Sub -total 20,184 1,333 7,388 Safety factors: +0% +0% +0% Total w/ safety factors: ------------------ --------- 20;184 1,333 . 7,388 } �z p'� 1 j- Fib 'f§ My Y 1C.... h }iw e`+ft • 4' «N'. Roof-1-4-Susp.C-L 1,000 0.50 6.8 0.060 409 1.980 1,980 Wall-1-E-C-D 147 1 11.9 0.095 166 3.135 461 Wall-2-W-C-D 240 1 15.9 0.095 362 3.135 752 GIs-E-1-90-Tran 72.0 1.000 1 1.040 37 36.300 2,614 O%S-O-WS-Solar 72.0 0.550 220 0.800 6,970 GIs-E-1-90-Tran 21.0 1.000 1 1.040 11 36.300 762 0%S-0-WS-Solar 21.0 0.550 220 0.800 2,033 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 20,184 1,333 7,388 Safety factors: +0% +0% +0% Total w/safety factors: --------- --------- .... 20,184 1,333 ----- 7,388 F Roof-1-4-Susp.C-L 1,000 0.50 6.8 0.060 409 1.980 1,980 - Wall-1-E-C-D 147 1 11.9 0.095 166 3.135 461 Wall-2-W-C-D 240 1 15.9 0.095 362 3.135 752 GIs-E-1-90-Tran 72.0 1.000 1 1.040 37 36.300 2,614 0%S-0-WS-Solar 72.0 0.550 220 0.800 6,970 GIs-E-1-90-Tran 21.0 1.000 1 1.040 11 36.300 762 0%S-0-WS-Solar 21.0 0.550 2-20 0.800 2,033 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 20,184 1,333 7,388 Safety factors: +00/0 +0% +0% Total w/safety factors: --- ----- --------- --- 20,184 1,333 --- -- 7,388 Roof-1-4-Susp.C-L 1,000 0.50 6.8 0.060 409 1.980 1,980 Wall-1-E-C-D 147 1 11.9 0.095 166 3.135 461 Wall-2-W-C-D 240 1 15.9 0.095 362 3.135 752 GIs-E-1-90-Tran 72.0 1.000 1 1.040 37 36.300 2,614 $ ' W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Cadton Plaza.CHV Friday, July 06, 2007, 11:40 AM liya Iyto 8 AC load Ga fati Pmg 1< *< , h� Sbtixarf# v alin�n d , 0+ done sDfa��ed_L'oaLds (At. Peak4Ti�nes) (can'dj) _ , ._ ... 4 ra..y......K ;. (Zloyne t j•�r{ �`� � T�+ s�AM1ff*✓✓A� �'n' L`^ . �iL.aj .f" .('� �` ✓Y �4'# i, �Rf l'��` �` J vi Yr � ? +'a}�'S � �0.4+� ` y-� „4N��,��i�F 0%S-0-WS-Solar 72.0 0.550 220 0.800 6,970 GIs-E-1-90-Tran 21.0 1.000 1 1.040 11 36.300 762 0%S-0-WS-Solar 21.0 0.550 220 0.800 2,033 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 20,184 1,333 7,388 Safety factors: +0% +0% +01/0 Totalw/safety factors: ---- ---- 20,184 --------- --------- 1,333 7,388 yi Roof-1-4-Susp.C-L 1,000 0.50 6.8 0.060 409 1.980 1,980 Wall-1-E-C-D 147 1 11.9 0.095 166 3.135 461 Wall-2-W-C-D 240 1 15.9 0.095 362 3.135 752 GIs-E-1-90-Tran 72.0 1.000 1 1.040 37 36.300 2,614 0%S-0-WS-Solar 72.0 0.550 220 0.800 6,970 GIs-E-1-90-Tran 21.0 1.000 1 1.040 11 36.300 762 0%S-0-WS-Solar 21.0 0.550 220 0.800 2,033 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub total 20,184 1,333 7,388 Safety factors: +0% +0% +00/0 Total w/ safety factors: ---- ---- 20,184 --------- ------- 1,333 7,388 -Nf9't` �` {i iNXXC$�� �'v `�' �w�.Vi',fS iRS'#'��i?Y�tn aikC ��v11..i ."a`�f.��h`.SW v31.'_`-'£•v'i ,�=t'�!' �M�F�N Roof-1-4-Susp.C-L 1,000 0.50' 6.8 0.060 409 1.980 1,980 Wall-1-E-C-D 147 1 11.9 0.095 166 3.135 461 Wall-2-W-C-D 240 1 15.9 0.095 362 3.135 752 GIs-E-1-90-Tran 72.0 1.000 1 1.040 37 36.300 2,614 0%,S-0-WS-Solar 72.0 0.550 220 0.800 6,970 GIs-E-1-90-Tran 21.0 1.000 1 1.040 11 36.300 762 0%S-0-WS-Solar 21.0 0.550 220 0.800 2,033 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 20,184 1,333 7,388 Safety factors: +0% +0% +0% Total w/ safety factors: 20,184 1,333 7,388 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV. - Friday, July 06, 2007, 11:40 AM .ti r^ � e t � F a � S _ � v f � .A � S s. •� y, 1!� # Fri, +/f, ',�r'J.fsY ' rh`"i$�^XS yii .it Roof-1-4-Susp.C-L 1,000 0.50 6.8 0.060 409 1.980 1,980 Wall-1-E-C-D 147 1 11.9 0.095 166 3.135 461 Wall-2-W-C-D 240 1 15.9 0.095 362 3.135 752 GIs-E-1-90-Tran 72.0 1.000 1 1.040 37 36.300 2,614 O%S-O-WS-Solar 72.0 0.550 220 0.800 6,970 GIs-E-1-90-Tran 21.0 1.000 1 1.040 11 36.300 762 0%S-0-WS-Solar 21.0 0.550 220 0.800 2,033 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 20,184 1,333 7,388 Safety factors: +0% +0% +0% Total w/ safety factors: ------------------ 20,184 1,333 --------- 7,388 Roof-1-4-Susp.C-L 1,000 0.50 6.8 0.060 409 1.980 1,980 Wall-1-E-C-D 147 1 11.9 0.095 166 3.135 461 Wall-2-W-C-D 240 1 15.9 0.095 362 3.135 752 GIs-E-1-90-Tran 72.0 1.000 1 1.040 37 36.300 2,614 0'/oS-O-WS-Solar 72.0 0.550 220 0.800 6,970 GIs-E-1-90-Tran 21.0 1.000 1 1.040 11 36.300 762 0%S-0-WS-Solar 21.0 0.550 220 0.800 2,033 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 20,184 1,333 7,388 Safety factors: +0% +0% +00/0 Total w/ safety factors: --------- --------- 20,184 1,333 --------- 7,388 Roof-1-4-Susp.C-L 1,000 0.50 6.8 0.060 409 1.980 1,980 Wall-1-E-C-D 147 1 11.9 0.095 166 3.135 461 Wall-2-W-C-D 240 1 15.9 0.095 362 3.135 752 GIs-E-1-90-Tran 72.0 1.000 1 1.040 37 36.300 2,614 0%S-0-WS-Solar 72.0 0.550 220 0.800 6,970 GIs-E-1-90-Tran 21.0 1.000 1 1.040 11 36.300 762 0%S-0-WS-Solar 21.0 0.550 220 0.800 2,033 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 20,184 1,333 7,388 Safety factors: +0% +0% +0% W:\06 PROJECTS\06002-07 Lexington Square\CalculationsWech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM m j ��� � FLG Zone,Detai►ledLoads AtlZvnePea1�:Ties)�con#`d) >,, u, �`�"� r�.. � I �"�" ��.���.��` �� .{�_ C1--�-AG�.�'.Sk�� .�,.� ,�, {a .�_�,`�€�. a�tf1 � • rat ��,�,�'��? Total W/ safety factors: 20,184 1,333 7,388 `y{ Roof-1-4-Susp.C-L 1,000 0.50 6.8 0.060 409 1.980 1,980 Wall-1-E-C-D 147 1 11.9 0.095 166 3.135 461 Wall-2-W-C-D 240 1 15.9 0.095 362 3.135 752 GIs-E-1-90-Tran 72.0 1.000 1 1.040 37 36.300 2,614 0%S-0-WS-Solar 72.0 0.550 220 0.800 6,970 GIs-E-1-90-Tran 21.0 1.000 1 1.040 11 36.300 762 0%S-0-WS-Solar 21.0 0.550 220 0.800 2,033 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 20,184 1,333 7,388 Safety factors: +0% +0% +0% Total w/ safety factors: ---- ------------- --------- 20,184 1,333 7,388 R6of-1-4-Susp.C-L 4,556 0.50 23.8 0.060 6,509 1.980 9,021 Wall-1-NE-C-D 255 1 23.1 0.095 560 3.135 799 Wall-2-W-C-D 816 1 23.9 0.095 1,851 3.135 2,558 Wall-3-S-C-D 816 1 23.0 0.095 1,783 3.135 2,558 GIs-NE-1-90-Tran 54.0 1.000 13 1.040 702 36.300 1,960 0%S-0-WS-Solar 54.0 0.550 151 0.120 538 GIs-NE-1-90-Tran 63.0 1.000 13 1.040 819 36.300 2,287 0%S-0-WS-Solar 63.0 0.550 151 0.120 628 Lights-Prof=O 9,112 1.000 31,091 Equipment-Prof=O 2,278 1.000 7,773 0 People-Prof=O 30.4 1.000 7,593 6,075 Floor slab 167 20.460 3,417 Sub -total 59,848 6,075 22,601 Safety factors: +0% +0% +0% Total w/ safety factors: --------- ------ -- --------- 59,848 6,075 22,601 g Rolf-1-4-Susp.C-L 1,000 0.50 23.8 0.060 1,429 1.980 1,980 Wall-1-N-C-D 147 1 12.5 0.095 175 3.135 461 Wall-2-S-C-D 240 1 23.0 0.095 524 3.135 752 GIs-N-1-90-Tran 72.0 1.000 13 1.040 936 36.300 2,614 0%S-0-WS-Solar 72.0 0.550 38 0.910 1,369 GIs-N-1-90-Tran 21.0 1.000 13 1.040 273 36.300 762 0%S-0-WS-Solar 21.0 0.550 38 0.910 399 Lights-Prof=O 2,000 1.000 6,824 W:\06 PROJECTS\06002-07 Le:angton Square\Calculations\Mech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM. CI _1w Ogg N V. kit Elm RG 4' Tm I D, V * PW Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 15,303 1,333 7,388 Safety factors: +0% +00/0 +0% Total w/ safety factors: . ....... --------- 15,303 1,333 --------- 7,388 Roof-1-4-Susp.C-L 1,000 0.50 23.8 0.060 1,429 1.980 1,980 Wall-I-N-C-D 147 1 12.5 0.095 175 3.135 461 Wall-2-S-C-D 240 1 23.0 0.095 524 3.135 752 GIs-N-1-90-Tran 72.0 1.000 13 1.040 936 36.300 2,614 0%S-0-WS-Solar 72.0 0.550 38 0.910 1,369 GIs-N-1 -90-Tran 21.0 1.000 13 1.040 273 36.300 762 0%S-0-WS-Solar 21.0 0.550 38 0.910 399 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 15,303 1,333 7,388 Safety factors: +0% +0% +0% Total w/ safety factors: --------- 15,303 1,333 -------- 7,388 Roof-1 -4-Susp.C-L 1,000 0.50 23.8 0.060 1,429 1.980 1,980 Wall-l-N-C-D 147 1 12.5 0.095 175 3.135 461 Wall-2-S-C-D 240 1 23.0 0.095 524 3.135 752 GIs-N-1-90-Tran 72.0 1.000 13 1.040 936 36.300 2,614 0%S-0-WS-Solar 72.0 0.550 38 0.910 1,369 GIs-N-1-90-Tran 21.0 1.000 13 1.040 273 36.300 762 0%S-0-WS-Solar 21.0 0.550 38 0.910 399 Lights-Prof--o 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 15,303 1,333 7,388 Safety factors: +00/0 +0% +0% Total w/ safety factors: --------- 15,303 1,333 --------- 7,388 Roof-1-4-Susp.C-L 1,000 0.50 23.8 0.060 1,429 1.980 1,980 Wall-l-N-C-D 147 1 12.5 0.095 175 3.135 461 Wall-2-S-C-D 240 1 23.0 0.095 524 3.135 752 WA06 PROJECTS\06002-07 Lexington SquarekCalculationsWechkCadton Plaza.CHV Friday, July 06, 2007, 11:40 AM Ohria P l�Co ra)itl �1i1 &�Rafa tat�Ipo ,�� ",� � �- � f (e C3g�i$t Zone Detailed L�rads (A#Zone ..r. • 5 '� ��k1� 5$�Y,�b teF k-j �I'f-h S3r��A1��C�3� �� � i"'`� 'Y'F` ri'`..'Ru^N i �. q. y� 1..(j Nu^tL;,^� ',( +C5 5r �°si-Q�%3Yi.r?$'nL' Y" `�aa 9! t f�9�}� �M "744h� '�"�.� � � � .��� � � �✓a �`i 4"h'Z. yyY 11 GIs-N-1-90-Tran 72.0- 1.000 13 1.040 936 36.300 2,614 O%S-O-WS-Solar 72.0 0.550 38 0.910 1,369 -GIs-N-1-90-Tran 21.0 1.000 13 1.040 273 36.300 762 0%S-0-WS-Solar 21.0 0.550 38 0.910 399 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 - 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub-totai 15,303 1,333 7,388 Safety factors: +0% +0% +0% Total w/ safety factors: --------------------------- 15,303 1,333 7,388 Roof-1-4-Susp.C-L 1,000 0.50 23.8 0.060 1,429 1.980 1,980 Wall-1-N-C-D 147 1 12.5 0.095 175 3.135 461 Wall-2-S-C-D 240 1 23.0 0.095 524 3.135 752 GIs-N-1-90-Tran 72.0 1.000 13 1.040 936 36.300 2,614 0%S-0-WS-Solar 72.0 0.550 .38 0.910 1,369 GIs-N-1-90-Tran 21.0 1.000 13 1.040 273 36.300 762 0%S-0-WS-Solar 21.0 0.550 38 0.910 399 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 15,303 1,333 7,388 Safety factors: +0% +0% +00/0 Total w/ safety factors: ------------------ --------- 1115,303 1,333 7,388 Roof-1-4-Susp.C-L 1,000 0.50 23.8 0.060 1,429 1.980 1,980 Wall-1-N-C-D 147 1 12.5 0.095 175 3.135 461 Wall-2-S-C-D 240 1 23.0 0.095 524 3.135 752 GIs-N-1-90-Tran 72.0 1.000 13 1.040 936 36.300 2,614 O%S-O-WS-Solar 72.0 0.550 38 0.910 1,369 GIs-N-1-90-Tran 21.0 1.000 13 1.040 273 36.300 762 0%S-0-WS-Solar 21.0 0.550 38 0.910 399 Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1.000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 15,303 1,333 7,388 Safety factors: +0% +0% +0% Total W/ safety factors: --------- --------- --------- 15,303 1,333 7,388 W:\06 PROJECTS\06002-07 Lexington Square\Calculations\Mech\Carlton Plaza.CHV Friday, July 06, 2007, 11:40 AM sCh �FI�o �6fH��oaila alc In Cam t rna�IP t�^'ar�EIIteSo�m6eg2 Lblso rcPlerce FL 3498 r n �. , Zpne'Deailed loadsj(Af Zone,peak Timis (,carit'd _. .-a> IN, Roof-1-4-Susp.C-L 1,006 0.50 23.8 0.060 1,429 1.980 1,980 Wall-1-N-C-D 147 1 12.5 0.095 175 3.135 461 Wall-2-S-C-D 240 1 23.0 0.095 524 3.135 752 GIs-N-1-90-Tran 72.0 1.000 13 1.040 936 36.300 2,614 O%S-O-WS-Solar 72.0 0.550 38 0.910 1,369 GIs-N-1-90-Tran 21.0 1.000 13 1.040 273 36.300 762 0%aS-0-WS-Solar 21.0 0.550 38 0.910 399 _ Lights-Prof=O 2,000 1.000 6,824 Equipment-Prof=O 500 1.000 1,706 0 People-Prof=O 6.7 1:000 1,667 1,333 Floor slab 40 20.460 818 Sub -total 15,303 1,333 7,388 Safety factors: +0% +0% +0% Total w/ safety factors: --------- 15,303 ------ -- 1,333 --------- 7,388 °��=' eta ape s'(sen Itile'ii�- y9t�i� t p" , Ai a' c7t`er'1;�4 ioup ©2 0 0 O,�v ttu�tionf Y Roof-1-4-Susp.C-L 1,400 0.50 19.8 0.060y 1,664 1.980 2,772 Wall-1-N-C-D 243 1 8.5 0.095 196 3.135 762 Wall-2-E-C-D 534 1 28.9 0.095 1,465 3.135 1,674 Wall-3-S-C-D 336 1 16.0 0.095 511 3.135 1,053 GIs-N-1-90-Tran 72.0 1.000 15 1.040 1,086 36.300 2,614 0%S-0-WS-Solar 72.0 0.550 38 0.820 1,234 GIs-N-1-90-Tran 21.0 1.000 15 1.040 317 36.300 762 0%S-0-WS-Solar 21.6 0.550 38 0.820 360 GIs-E-1-90-Tran 54.0 1.000 15 1.040 814 36.300 1,960 0%S-0-WS-Solar 54.0 0.550 220 0.200 1,307 Lights-Prof=O 2,800 1.000 9,554 Equipment-Prof=O 700 1.000 2,388 0 People-Prof=O 9.3 1.000 2,333 1,867 Floor slab -------- --- 105 20.460 2,148 ------ Sub-total -- - ---- - — - ------- - -- - 23,229 --- ------ -- 1,867 13,746 Safety factors: +0% +0% +0% Total w/ safety factors: --------- 23,229 --------- 1,867 --------- 13,746 W:\06 PROJECTS\06002-W Lepngton Square\Calculations\Mech\Cadton Plaza.CHV Friday, July 06, 2007, 11:40 AM Project Name: Carlton Square Project Title: Carlton Square Address: US 1 & Kitterman Rd State: FL Zip: 0 Owner: Carlton Square EnergyGauge FLA/COM 2004 v3.00 Proiect Information Orientation: East Building Type: Retail Building Classification: New Finished building No.of Storeys: 1 GrossArea: 24956 SF Zones No Acronym Description Type Area [stl Multiplier Total Area isfl 1 Unit I Zone 1 CONDITIONED 1000.0 1 1000.0 ❑ 2 Unit 2 Zone 2 CONDITIONED 1000.0 1 1000.0 ❑ 3 Unit 13 & 14 Zone 3 CONDITIONED 4556.0 1 4556.0 ❑ 4 Unit 15 Zone 14 CONDITIONED 1000.0 1 1000.0 ❑ 5 Unit 22 Zone 21 CONDITIONED 1400.0 1 1400.0 ❑ 6 Unit 3 Zone 3 CONDITIONED 1000.0 1 1000.0 ❑ 7/6/2007 Energy;Gauge FLA/COM 2004 v3.00 1 m 7 Unit 4 Zone 4 CONDITIONED 1000.0 1 1000.0 ❑ 8 Unit 5 Zone 5 CONDITIONED 1000.0 1 1000.0 ❑ 9 Unit 6 Zone 6 CONDITIONED 1000.0 1 1000.0 ❑ 10 Unit 7 Zone 7 CONDITIONED 1000.0 1 1000.0 ❑ 11 Unit 8 Zone 8 CONDITIONED 1000.0 1 1000.0 ❑ 12 Unit 9 Zone 9 CONDITIONED 1000.0 1 1000.0 ❑ 13 Unit 10 Zone 10 CONDITIONED 1000.0 1 1000.0 ❑ 14 Unit I Zone 11 CONDITIONED 1000.0 1 1000.0 ❑ 15 Unit 12 Zone 12 CONDITIONED 1000.0 1 1000.0 ❑ 16 Unit 16 Zone 15 CONDITIONED 1000.0 1 1000.0 ❑ 17 Unit 17 Zone 16 CONDITIONED 1000.0 1 1000.0 ❑ 18 Unit 18 Zone 17 CONDITIONED 1000.0 1 1000.0 ❑ 19 Unit 19 Zone 18 CONDITIONED 1000.0 1 1000.0 ❑ 20 Unit 20 Zone 19 CONDITIONED 1000.0 1 1000.0 ❑ 21 Unit 21 Zone 20 CONDITIONED 1000.0 1 1000.0 ❑ Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] [ft] [ft] plier [sf] [ct] In Zone: Unit 1 1 PrOZoISp1 ZoOSpl Sales Area 50.00 20.00 12.00 I 1000.0 12000.0 ❑ In Zone: Unit 2 I Pr0Zo2Sv1 ZoOSpI Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 ❑ In Zone: Unit 13 & 14 1 PrOZo3Sp1 Zo0Sp1 Sales Area 68.00 67.00 12.00 1 4556.0 54672.0 ❑ In Zone: Unit 15 1 PrOZo4Spl ZoOSpl Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 ❑ In Zone: Unit 22 1 Pr0Zo5SpI ZoOSpl Sales Area 50.00 28.00 12.00 1 1400.0 16800.0 ❑ In Zone: Unit 3 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 I PrOZo2SD1 ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 ❑ In Zone: Unit 4 1 PrOZo2Sp1 ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 ❑ In Zone: Unit 5 1 PrOZo2Sv1 ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 ❑ In Zone: Unit 6 1 PrOZo2Spl ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 ❑ In Zone: Unit 7 1 PrOZo2spl ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 ❑ In Zone: Unit 8 1 PrOZo2Spl ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 ❑ In Zone: Unit 9 I PrOZo2Sp1 ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 ❑ In Zone: Unit 10 I PrOZo2Spl ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 El In Zone: Unit 11 I PrOZo2Sp1 ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 ❑ In Zone: Unit 12 1 PrOZo2Spl ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 In Zone: Unit 16 1 PrOZo4spl ZoOSpl Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 El In Zone: Unit 17 1 PrOZo4Spl ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 Q In Zone: Unit 18 1 PrOZo45pl ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 El In Zone: Unit 19 I PrOZo4Spl ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 ❑ In Zone: Unit 20 1 PrOZo4Spl ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 El In Zone: Unit 21 1 PrOZo4Sp1 ZoOSp1 Sales Area 50.00 20.00 12.00 1 1000.0 12000.0 El 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 3 M Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: Unit 1 In Space: Pr0Zo1Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 In Zone: Unit 2 In Space: Pr0Zo2Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 ❑ In Zone: Unit 13 & 14 In Space: Pr0Zo3Sp1 1 Compact Fluorescent General Lighting 1 3000 3000 Manual On/Off 4 ❑ In Zone: Unit 15 In Space: Pr0Zo4Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 ❑ In Zone: Unit 22 In Space: PrOZo5Sp1 1 Compact Fluorescent General Lighting 1 2000 2000 Manual On/Off 6 In Zone: Unit 3 In Space: PrOZo2Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 El In Zone: Unit 4 In Space: Pr0Zo2Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 ❑ In Zone: Unit 5 In Space: Pr0Zo2Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 In Zone: Unit 6 In Space: Pr0Zo2Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 In Zone: Unit 7 In Space: Pr0Zo2Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 ❑ 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 4 In Zone: Unit 8 In Space: Pr0Zo2Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 ❑ In Zone: Unit 9 In Space: Pr0Zo2Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 In Zone: Unit 10 In Space: Pr0Zo2Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 ❑ In Zone: Unit 11 In Space: Pr0Zo2Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 In Zone: Unit 12 In Space: Pr0Zo2Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off, 4 In Zone: Unit 16 In Space: PrOZo4Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 ❑ In Zone: Unit 17 In Space: Pr0Zo4Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 El In Zone: Unit 18 In Space: Pr0Zo4Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 In Zone: Unit 19 In Space: Pr0Zo4Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 In Zone: Unit 20 In Space: Pr0Zo4Sp1 I Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 In Zone: Unit 21 In Space: Pr0Zo4Sp1 1 Compact Fluorescent General Lighting 1 1500 1500 Manual On/Off 4 7/6/2007 Energy,Gauge FLA/COM 2064 v3.00 5 Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value IN [ft] plier [sf] [Btu/hr. A F] Capacity [lb/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: Unit 1 1 PrOZolWal 5/8" stucco 20.00 10.00 1 200.0 East 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZolWe2 5/8" stucco 49.00 10.00 1 490.0 North 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 3 PrOZOlWa3 5/8" stucco 20.00 10.00 1 200.0 West 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: Unit 2 1 PrOZ02Wal 5/8" stucco 20.00 10.0& 1 200.0 East 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo2Wa2 5/8" stucco 20.00 10.00 1 200.0 West 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: Unit 13 & 14 1 PrOZ03Wal 5/8" stucco 32.00 10.00 1 320.0 NorthEast 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo3Wa2 5/8" stucco 68.00 10.00 1 680.0 West 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 3 PrOZo3Wa2 5/8" stucco 68.00 10.00 1 680.0 South 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp F/6/2007 EnergyGauge FLA/COM 2004 v3.00 6 In Zone: Unit 15 1 Pr0Zo4Wa1 5/8" stucco 20.00 10.00 1 /8".CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo4Wa2 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" GYP In Zone: Unit 22 1 Pr0Zo5Wa1 5/8" stucco 28.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo5Wa2 5/8" stucco 49.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" GYP 3 Pr0Zo5Wa3 5/8" stucco 28.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: Unit 3 1 Pr0Zo2Wa1 5/8" stucco 20.00 10.00 1 /8",CMU/3/4"IS0 BTWN24"oc/.5" GYP 2 Pr0Zo2Wa2 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: Unit 4 1 Pr0Zo2Wa1 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" GYP 2 PrOZo2Wa2 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.S' Gyp In Zone: Unit 5 7/6/2007 200.0 North 0.2067 5.731. 34.65 4.8 ❑ 200.0 South 0.2067 5.731 34.65 4.8 ❑ 1 280.0 North 0.2067 5.731 34.65 4.8 ❑ 1 490.0 East 0.2067 5.731 34.65 4.8 ❑ 11 280.0 South 0.2067 5.731 34.65 4.8 ❑ it 200.0 East 0.2067 5.731 34.65 4.8 ❑ 11 200.0 West 0.2067 5.731 34.65 4.8 ❑ 11 200.0 East 0.2067 5.731 34.65 4.8 ❑ 11 200.0 West 0.2067 5.731 34.65 4.8 ❑ II EnergyGauge FLA/COM 2004 v3.00 7 M I PrOZo2Wa1 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo2Wa2 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: Unit 6 1 PrOZo2Wa1 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo2Wa2 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: Unit 7 1 PrOZo2Wa1 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo2Wa2 5/8" stucco 20.00 10.00 1 /8"CMU/3/4'4s0 BTWN24"oc/.5" Gyp In Zone: Unit 8 1 PrOZo2Wa1 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" GYP 2 PrOZo2Wa2 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: Unit 9 1 . PrOZo2Wa1 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 200.0 East 0.2067 5.731 34.65 4.8 200.0 West 0.2067 5.731 34.65 4.8 ❑ ji 200.0 East 0.2067 5.731 34.65 4.8 ❑ ll 200.0 West 0.2067 5.731 34.65 4.8 ❑ 11 200.0 East 0.2067 5.731 34.65 4.8 ❑ 11 200.0 West 0.2067 5.731 34.65 4.8 ❑ II 200.0 East 0.2067 5.731 34.65 4.8 ❑ 11 200.0 West 0.2067 5.731 34.65 4.8 ❑ 11 200.0 East 0.2067 5.731 34.65 4.8 ❑ ll 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 8 2 PrOZo2Wa2 5/8" stucco 20.00 10.00 1 200.0 West 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: Unit 10 I PrOZo2Wa1 5/8" stucco 20.00 10.00 1 200.0 East 0.2067 5.131 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo2Wa2 5/8" stucco 20.00 10.00 1 200.0 West 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" GYP In Zone: - Unit 11 1 PrOZo2Wa1 5/8" stucco 20.00 10.00 1 200.0 East 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo2Wa2 5/8" stucco 20.00 10.00 1 200.0 West 0.2067, 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: Unit 12 1 PrOZo2Wa1 5/8" stucco 20.00 10.00 1 200.0 East 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo2Wa2 5/8" stucco 20.00 10.00 1 200.0 West 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: Unit 16 1 PrOZo4Wa1 5/8" stucco 20.00 10.00 1 200.0 North 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZ04Wa2 5/8" stucco 20.00 10.00 1 200.0 South 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: Unit 17 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 9 0 1 PrOZo4Wa1 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" GYP 2 PrOZo4Wa2 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: Unit 18 1 PrOZo4Wa1 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo4Wa2 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" GYP In Zone: Unit 19 1 PrOZo4Wa1 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" GYP 2 PrOZo4Wa2 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: Unit 20 1 PrOZo4Wa1 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo4Wa2 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" GYP In Zone: Unit 21 1 PrOZo4Wa1 5/8" stucco 20.00 10.00 1 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 7/6/2007 200.0 North 0.2067 5.731 34.65 4.8 ❑ 200.0 South 0.2067 5.731 34.65 4.8 ❑ 200.0 North 0.2067 5.731 34.65 4.8 ❑ ll 200.0 South 0.2067 5.731 34.65 4.8 ❑ 11 200.0 North 0.2067 5.731 34.65 4.8 ❑ II 200.0 South 0.2067 5.731 34.65 4.8 ❑ 11 200.0 North 0.2067 5.731 34.65 4.8 ❑ 11 200.0 South 0.2067 5.731 34.65 4.8 ❑ 11 200.0 North 0.2067 5.731 34.65 4.8 ❑ ll EnergyGaoge FLA/COM 2004 v3.00 10 2 PrOZo4Wa2 5/8" stucco 20.00 10.00 1 200.0 South 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Bta/hr sf F] [ft] [ft] plier �sf] In Zone: Unit 1 In Wall: East 1 PrOZolWalWil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 2 PrOZolWalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 In Wall: North 1 PrOZOlWa2Wil User Defined No 1.2500 0.82 0.76 3.00 6.00 3 54.0 El In Zone: Unit 10 In Wall: East I PrOZ02WalWil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 2 PrOZo2Wa1Wi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 In Zone: Unit 11 In Wall: East 1 PrOZo2Wa1Wi1 User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 El 2 PrOZo2Wa1Wi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 In Zone: Unit 12 In Wall: East 1 PrOZ02WalWil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 El 2 PrOZo2Wa1Wi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 In Zone: Unit 13 & 14 In Wall: North East 1 PrOZo3Wa1Wil User Defined No 1.2500 0.82 0.76 3.00 6.00 2 36.0 2 PrOZo3Wa1Wi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 In Zone: Unit 15 In Wall: North I PrOZo4Wa1Wil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 2 PrOZo4WalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 7/6/2007 EnergyGauge FLA/COM 200i v3.00 11 m In Zone: Unit 16 In Wall: North 1 PrOZo4Wa1Wi1 User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 2 PrOZo4WalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 In Zone: Unit 17 In Wall: North I PrOZo4WalWil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 El 2 PrOZo4WalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 In Zone: Unit 18 In Wall: North 1 PrOZo4WalWil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 2 PrOZo4WalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 In Zone: Unit 19 In Wall: North 1 PrMo4WaMil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 El 2 PrOZo4WalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 El In Zone: Unit 2 In Wall: East 1 PrOZo2WalWil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 2 PrOZo2Wa1Wi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 ❑ In Zone: Unit 20 In Wall: North 1 PrOZo4Wa1Wil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 2 PrOZo4WalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 H In Zone: Unit 21 In Wall: North 1 PrOZo4Wa1Wil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 2 PrOZo4WalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 ❑ In Zone: Unit 22 In Wall: East 1 PrOZo5Wa2Wil User Defined No 1.2500 0.82 0.76 3.00 6.00 3 54.0 In Wall: North 1 PrOZo5WaMl User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 2 PrOZo5WalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 In Zone: Unit 3 In Wall: East 1 PrOZo2WalWil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 2 PrOZo2Wa1Wi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 7/6/2007 EnergyGauge FLAXOM 2004 v3.00 12 In Zone: Unit 4 In Wall: East 1 PrOZo2WalWil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 2 PrOZo2WalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 El In Zone: Unit 5 In Wall: East 1 PrOZo2WalWil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 El 2 PrOZo2WalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 El In Zone: Unit 6 In Wall: East 1 PrOZo2WalWil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0 2 PrOZo2WalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 In Zone: Unit 7 In Wall: East 1 PrOZo2WalWi1 User Defined No 1.2500 0.82 0.76 3.00 6.00 4• 72.0 2 PrOZo2WalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00' 1 21.0 In Zone: Unit 8 In Wall: East 1 PiOZo2Wa1Wil User Defined No 1.2500 0.82 0.76 3.00 6.00 4 72.0El 2 PrOZo2WalWi2 User Defined No - 1.2500 0.82 0.76 3.00 7.06 1, 21.0 In Zone: Unit 9 In Wall; East " 1 PrOZo2WalWil User Defined No 1.2500 0.82 0.76 3.00 ' 6.60 4` 72.0 ET 2 PrOZo2WalWi2 User Defined No 1.2500 0.82 0.76 3.00 7.00 1 21.0 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. s£ F] [lb/cf] [Btu/s£ F] [h.sLF/Btu] In Zone: Unit 1 In Wall: West 1 PrOZolWa3Drl Solid core flush No 3.00 7.00 1 21.0 0.6061 0.00 0.00 1.65 ❑ (1.75") In Zone: Unit 2 In Wall: West 1 PrOZo2Wa2Drl Solid core flush No 3.00 7.00 1 21.0 0.6061 0.00 0.00 1.65 (1.75") In Zone: Unit 13 & 14 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 13 0 a In Wall: West 1 PrOZo3Wa2Drl Solid core flush No 3.00 7.00 1 21.0 0.6061 0.00 0.00 (1.75") In Wall: South 1 PrOZo3Wa2Drl Solid core flush No 3.00 7.00 1 21.0 0.6061 0.00 0.00 (1.75") In Zone: Unit 15 In Wall: South 1 PrOZo4Wa2Drl Solid core flush No 3.00 7.00 1 21.0 0.6061 0.00 0.00 (1.75") In Zone: Unit 22 In Wall: South 1 PrOZo5Wa31)rl Solid core flush No 3.00 7.00 1 21.0 0.6061 0.00 0.00 (1.75") In Zone: Unit 3 In Wall: West 1 PrOZo2Wa2Drl Solid core flush No 3.00 7.00 1 21.0 0.6061 0.00 0.00 (1.75") _ In Zone: Unit 4 In Wall: West 1 PrOZo2Wa2Drl Solid core flush No 3.00 7.00 1 21.0 (1.75") In Zone: Unit 5 In Wall: West 1 PrOZo2Wa2Drl Solid core flush No 3.00 7.00 1 . 21.0 (1.75") In Zone: Unit 6 In Wall: West 1 PrOZo2Wa2Dr1 Solid core flush No 3.00 7.00 1 21.0 (1.75") In Zone: Unit 7 In Wall: West 1 PrOZo2Wa2Drl Solid core flush-- No 3.00 7.00 1 21.0 (1.75") In Zone: Unit S In Wall: West 1 PrOZo2Wa2Drl Solid core flush No 3.00 7.00 1 21.0 In Zone: Unit 9 In Walh., West 1 PrOZo2Wa2Drl Solid core flush No 3.00 7.00 1 21.0 (1.75") 0.6061 0.00 0.00 0.6061 0.00 0.00 0.6061 0.00 0.00 0.6061 0.00 0.00 ;�x1�z.11�4110=fxfl( 0.6061 0.00 0.00 1.65 El II 1.65 D 11 1.65 D 1.65 D 1.65 D 1.65 D I' 1.65 D 1.65 D 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 14 In Zane: Unit 10 In Wall: West 1 PrOZo2Wa2Drl Solid core flush No (1.75") In Zone: Unit 11 In Wan: West 1 PrOZo2Wa2Drl Solid core flush No (1.75") In Zone: Unit 12 In Wall: West 1 PrOZo2Wa2Drl Solid core flush No (1.75") In Zone: Unit 16 In Wall: South 1 PrOZo4Wa2Drl Solid core flush No (1.75") In Zone: Unit 17 In Wall: South 1 PrOZo4Wa2Drl Solid core flush No (1.75") In Zone: Unit 18 In Wall: South 1 PrOZo4Wa2Drl Solid core flush No (1.75") In Zone: Unit 19 In Wall: South 1 PrOZo4Wa2Drl Solid core flush No (1.75") In Zone: Unit 20 In Wall: South I PrOZo4Wa2Drl Solid core flush No (1.75") In Zone: Unit 21 In Wall: South 1 PrOZo4Wa2Drl Solid core flush No (1.75") 3.00 7.00 1 21.0 0.6061 0.00 0.00 1.65 3.00 7.00 1 21.0 0.6061 0.00 0.00 1.65 3.00 7.00 1 21.0 0.6061 0.00 0.00 1.65 3.00 7.00 1 21.0 0.6061 0.00 0.00 1.65 i 3.00 7.00 1 21.0 0.6061 0.00 0.00 1.65 3.00 7.00 1 21.0 0.6061 0.00 0.00 1.65 3.00 7.00 1 21.0 0.6061 0.00 0.00 1.65 n. 3.00 7.00 1 21.0 0.6061 0.00 0.00 3.00 7.00 1 21.0 0.6061 0.00 0.00 7/6/2007 EnergyGauge FLAXOM 2004 v3.00 15 Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] [111 plier [sf] [deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: Unit 1 1 PrOZolRfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 2 1 PrOZo2Rfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 13 & 14 1 PrOZo3Rfl Mtl Bldg Roof/R-19 67.00 68.00 1 4556.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 15 1 PrOZo4Rfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 22 1 PrOZo5Rfl Mtl Bldg Roof/R-19 28.00 49.00 1 1372.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 3 1 PrOZo2Rfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 4 1 PrOZo2Rfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 5 1 PrOZo2Rfl' Mtl=B1dg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 6 1 PrOZo2Rfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 7 1 PrOZo2Rfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 8 1 PrOZo2Rf1 Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 9 1 PtOZo2Rf1 Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt 7/6/2007 EnergyGauge RI A/COM 2004 v3.00 16 In Zone: Unit 10 1 PrOZo2Rfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 Batt In Zone: Unit 11 1 PrOZo2Rfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 12 1 PrOZo2Rfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 16 I PrOZo4Rfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 17 1 PrOZo4Rfl Mtl BldgRoof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 18 1 PrOZo4Rfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 19 1 PrOZo4Rfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 20 1 PrOZo4Rfl Mtl Bldg Roof/R-19 20.00 49.00 1 980.0 0.06 0.0492 1.34 9.49 20.3 ❑ Batt In Zone: Unit 21 1 PrOZo4Rfl Mtl Bldg Roof/R-19 20.00 , 49.00 1 980.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt Skylights No Description Type U SHGC Vis.Trans W H (EMO Multiplier Area Total Area [Btu/hr sf F] [ft] IN [Sf] [Sf] In Zone: In Roof: 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 17 Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. Fl [Btu/sE F] [lb/cf] [h.sf.FBtul In Zone: Unit 1 1 PrOZolFll 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 0 floor, carpet and rubber pad In Zone: Unit 2 1 PrOZo2Fl1 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 (] floor, carpet and rubber pad In Zone: Unit 13 & 14 1 PrOZ03Fll 1. ft. soil, concrete 67.00 68.00 1 4556.0 0.1745 54.00 108.00 5.73 0 floor, carpet and rubber pad In Zone: Unit 15 1 PrOZo4Fl1 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 0 floor, carpet and rubber pad In Zone: Unit 22 1 PrOZo51711 1 ft. soil, concrete 28.00 49.00 1 1372.0 0.1745 54.00 108.00 5.73 0 floor, carpet and rubber pad ,. In Zone: Unit 3 1 PrOZo2F11 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 ED floor, carpet and rubber pad In Zone: Unit 4 1 PrOZo2Fll 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 0 floor, carpet and rubber pad In Zone: Unit 5 1 PrOZo2F11 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 0 floor, carpet and 11n rubber pad Zone: Unit 6 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 18 1 PrOZo2Fl1 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 ❑ floor, carpet and rubber pad In Zone: Unit 7 1 . PrOZo2Fll 1 ft. soil, concrete 20.00 49.00 1 980.0 .0.1745 54.00 108.00 5.73 ❑ floor, carpet and rubber pad In Zone: Unit 8 1 PrOZ02F11 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 ❑ floor, carpet and rubber pad In Zone: Unit 9, 1 PrOZo2F11 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 ❑ floor, carpet and rubber pad In Zone: Unit 10 1 PrOZo2Fll 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 ❑ floor, carpet and rubber pad In Zone: Unit 11 1 PrOZ02F11 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 ❑ floor, carpet and rubber pad In Zone: Unit 12 1 PrOZ02F11 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54:00 108.00 5.73 ❑ floor, carpet and rubber pad In Zone: Unit 16 1 PrOZo4Fll 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 ❑ floor, carpet and rubber.pad In Zone: Unit 17 1 PrOZ04F11 I ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 ❑ floor, carpet and rubber pad In Zone: Unit 18 4 1 PrOZo4Fl1 I ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 ❑ floor, carpet and rubber pad In Zone: Unit 19 7/6/2007 EnergyGauge FUAXOM 2004 v3.00 19 I Pr0Zo4Fll 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 0 floor, carpet and rubber pad In Zone: Unit 20 1 Pr0Zo4F11 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 ID floor, carpet and rubberpad In Zone: Unit 21 1 PrOZ041711 1 ft. soil, concrete 20.00 49.00 1 980.0 0.1745 54.00 108.00 5.73 0 floor, carpet and rubber pad Systems Pr0Sy1 System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 42000.00 13.00 8.00 Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 El 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 Constant Volume) 4 Air Distribution System (ADS System) 6.00 PrOSy2 System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 42000.00 13.00 8.00 Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 ❑ 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 ❑ Constant Volume) 4 Air Distribution System (ADS System) 6.00 ❑ 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 20 Pr0Sy15 System 15 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 36000.00 13.00 8.00 ❑ Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 ❑ 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 ❑ Constant Volume) 4 Air Distribution System (ADS System) 6.00 ❑ PrOSy22 System 22 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 48000.00 13.00 8.00 ❑ Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 ❑ 3 Air Handling System -Supply (Air Handler (Supply) - 1400.00 0.20 ❑ Constant Volume) 4 Air Distribution System (ADS System) 6.00 ❑ PrOSy3 System 3 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 ` Cooling System (Air Cooled < 65000 Btu/h Cooling 42000.00 13.00 8.00 ❑ Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 ❑ 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 ❑ Constant Volume) 4 Air Distribution System (ADS System) 6.00 ❑ 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 21 M w PrOSy4 System 4 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 BtuA Cooling 42000.00 13.00 8.00 Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 ❑ 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 ❑ Constant Volume) 4 Air Distribution System (ADS System) 6.00 PrOSy5 System 5 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV .1 Cooling System (Air Cooled < 65000 Btu/h Cooling 42000.00 13.00 8.00� Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 ❑ 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 Constant Volume) 4 Air Distribution System (ADS System) 6.00 PrOSy6 System 6 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV I Cooling System (Air Cooled < 65000 Btu/h Cooling 42000.00 13.00 8.00 Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 Constant Volume) 4 Air Distribution System (ADS System) 6.00 ❑ 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 22 PrOSy7 System 7 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 42000.00 13.00 8.00 Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 Constant Volume) 4 Air Distribution System (ADS System) 6.00 ❑ PrOSy8 System 8 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 42000.00 13.00 8.00 ❑ Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 ❑ 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 Constant Volume) 4 Air Distribution System (ADS System) 6.00 El PrOSy9 System 9 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 42000.00 13.00 8.00 Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 Constant Volume) 4 Air Distribution System (ADS System) 6.00 0 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 ' 23 Pr0Sy10 System 10 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 BhA Cooling 42000.00 13.00 8.00 Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 ❑ 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 ❑ Constant Volume) 4 Air Distribution System (ADS System) 6.00 Pr0Sy11 System 11 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Bta/h Cooling 42000.00 13.00 8.00 Capacity) 2 Heating, System,(ElectricFurnace) 17000.00 1.00 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00. 0.20 ❑ Constant Volume) 4 Air Distribution System (ADS System) 6.00 El Pr0Sy12 System 12 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 42000.00 13.00 8.00 ❑ Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 ❑ 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 Constant Volume) 4 Air Distribution System (ADS System) 6.00 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 24 Pr0Sy13 System 13 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled 65000 to 135000 Btu/h 120000.00 13.00 _ 8.00 Cooling Capacity) 2 Heating System (Electric Furnace) 34600.00 1.00 3 Air Handling System -Supply (Air Handler (Supply) - 4000.00 0.20 Constant Volume) 4 Air Distribution System (ADS System) 6.00 ❑ Pr0Sy16 System 16 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 36000.00 13.00 8.00 ❑ Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 ❑ 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 Constant Volume) 4 Air Distribution System (ADS System) 6.60 13 PrOSy17 System 17 Constant Volume Air Cooled Split No. Of Units 1. System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 36000.00 13.00 8.00 Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 3 Air Handling System -Supply (Air Handler (Supply) - 12b0.00 0.20 Constant Volume) 4 Air Distribution System (ADS System) 6.00 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 25 PrOSy18 System 18 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 36000.00 13.00 8.00 Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 3 . Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 Constant Volume) 4 Air Distribution System (ADS System) 6.00 ID PrOSy19 System 19 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 36000.00 13.00 8.00 13 Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 ID Constant Volume) 4 Air Distribution System (ADS System) 6.00 PrOSy20 System 20 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV I Cooling System (Air Cooled < 65000 Btu/h Cooling 36000.00 13.00 8.00 Capacity) 2 Heating System (Electric Furnace) 17000.00 1.00 3 Air Handling System -Supply (Air Handler (Supply) - 1200.00 0.20 ❑ Constant Volume) 4 Air Distribution System (ADS System) 6.00 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 26 Pr0Sy21 System 21 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 2 3 4 Cooling System (Air Cooled < 65000 Btu/h Cooling Capacity) Heating System (Electric Furnace) Air Handling System -Supply (Air Handler (Supply) - Constant Volume) Air Distribution System (ADS System) 36000.00 17000.00 1200.00 13.00 8.00 1.00 0.20 6.00 El ID Plant Equipment Category size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit}Cap.Unit UP Rt. Efficiency Loss Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Luminaires Luminaire [sf/ft/Nol Control Type Wattage 1W1 Piping No Type Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sf.F] Nomonal pipe Diameter [in] Insulation Is Runout? Thickness [in] 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 ' 27 Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] ASHULSg1C1rAll User Defined 1 1.2500 0.8200 0.7600 ❑ Frm Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity' Density SpecificHeat Used [h.sf.F/Btu] [ft] [Btu/b.ft.F] [lb/cf] [Btu/Ib.F] 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1/2IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ black 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/8IN Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [b.sf.FBtu] 1005 1 ft. soil, concrete floor, carpet and rubber pad No No 0.17 54.00 108.00 5.7 ❑ 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 28 Layer ' Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 2.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Bta/sLF] [lb/cf] [h.sf.F/Btu] 1011 5/8" stucco /8"CMU/3/4"ISO No No - 0.21 5.73 34.65 4.8 ❑ BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. [ft] Factor 1 268 0.625"stucco 0.0521 0.000 ❑ 2 42 8 in. Lightweight concrete block 0.6670 0.000 ❑ 3 269 .75" ISO BTWN24" oc 0.0625 0.000 ❑ 4 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1027 Solid core flush (1.75") No Yes 0.61 1.7 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 278 Solid core flush (1.75") 0.000 ❑ 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 29 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sLF] [Btu/sLF] [lb/cf] [h.sGFBtu] 1056 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 ❑ Layer Material Material Thickness Framing No. [it] Factor 1 94 BUILT-UP ROOFING, 3/8IN 0.0313 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 ❑ 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 30 .J Short Desc: Carlton Square Owner: Carlton Square Addressl: US 1 & Kitterman Rd Address2: Type: Retail PROJECT SUMMARY Description: Carlton Square City: Port St. Lucie State: FL Zip: 0 Class: New Finished building Jurisdiction: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) Cond Area: 24956 SF Cond & UnCond Area: 24956 SF No of Storeys: 1 Area entered from Plans 0 SF Permit No: 0 Max Tonnage 10 If different, write in: 7/6/2007 F\L'ccOQV -� EnergyGauge FLA/COM 2004 v3.00 I Compliance Summary Component Design Criteria Result Gross Energy Use 31,619.3 44,918.3 PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES None Entered PASSES None Entered None Entered None Entered Yes/No/NA RTANT NOTE: An input report of this design building must be submitted with this Compliance Report. 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 2 CERTIRCATIONS I hereby certify that the plans andd s ' tions cove ed by this calculation are in compliance with the Florida Energy Code cs� Prepared By: Building Official: Date: o' -�9 Date: I certify that this building is in compliance with t FLorida Energy Efficiency Code Owner Agent: Date: l If Required by Florida law, I hereby certify (*) that the system design is in compliance with the FLorida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: Reg No: Plumbing Designer: Reg No: (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 3 Project: Carlton Square Title: Carlton Square Type: Retail (WEA File: DAYTONABEACH.TMY) Compliance Design Reference Total 69.56 100.00 $31,619 $44,918 ELECTRICITY(MStulk 69.56 100.00 Whl$) 618773 889472 $31,619 $44,918 AREA LIGHTS 20.35 31.83 180973 283112 $9,248 $14,297 MISC EQUIPMT 18.05 18.05 160546 160546 i $8,204 $8,108 PUMPS & MIX 0.07 0.08 654 676 $33 $34 SPACE COOL 24.41 24.12 217127 214498 $11,095 $10,832 SPACE HEAT 1.13 0.94 10063 8323 $514 $420 VENT FANS 5.55 25.00 49410 222317 $2,525 $11,227 Credits & Penalties (if any): Modified Points: = 69.56 PASSES 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 4 External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None Project: Carlton Square Title: Carlton Square Type: Retail (WEA File: DAYTONABEACH.TMY) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- H) (sq.ft) Tasks CP CP ance PrOZo1Sp1 ,001 Sales Area 1,000 I 4 1 PASSES PrOZo2Spl ,001 Sales Area 1,000 1 4 1 PASSES PrOZo3Spl ,001 Sales Area 4,556 1 4 2 PASSES PrOZo4Sp1 ,001 Sales Area 1,000 1 4 1 PASSES PrOZo5Sp1 ,001 Sales Area 1,400 1 6 1 PASSES PrOZo2Sp1 ,001 Sales Area 1,000 1 4 1 PASSES PrOZ02SP1 ,001 Sales Area 1,000 1 4 1 PASSES PrOZo2Sp1 ,001 Sales Area 1,000 1 4 1 PASSES PrOZo2Sp1 ,001 Sales Area 1,000 1 4 1 PASSES PrOZo2Sp1 ,001 Sales Area 1,000 1 4 1 PASSES PrOZo2Sp1 ,001 Sales Area 1,000 1 4 1 PASSES PrOZo2Sp1 ,001 Sales Area 1,000 1 4 1 PASSES PrOZ02SP1 ,001 Sales Area 1,000 1 4 1 PASSES PrOZo2Sp1 ,001 Sales Area 1,000 1 4 1 PASSES PrOZo2Sp1 001 Sales Area 1,000 1 4 1 PASSES PrOZo4Spl 001 Sales Area 1,000 1 4 1 PASSES PrOZo4Sp1 001 Sales Area 1,000 1 4 1 PASSES PrOZo4Sp1 001 Sales Area 1,000 1 4 1 PASSES PrOZo4Sp1 ,001 Sales Area 1,000 1 4 1 PASSES PrOZo4Sp1 001 Sales Area 1,000 1 4 1 PASSES PrOZo4Sp1 001 Sales Area 1,000 1 4 1 PASSES PASSES 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 5 r Project: Carlton Square Title: Carlton Square Type: Retail (WEA File: DAYTONABEACH.TMY) System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy2 System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy15 System 15 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System 7/6/2007 EnergyGauge FLAICOM 2004 V3.00 6 PrOS}22 System 22 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy3 System 3 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr I Component Category Capacity Design Eff " Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy4 System 4 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy5 System 5 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 7 Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy6 System 6 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr I Component Category Capacity Design _ Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy7 System 7 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria fiance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy8 System 8 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System 7/6/2007 EnergyGauge FLA/COM 2004 V3.00 8 ' PrOSy9 System 9 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy10 System 10 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria fiance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSyll System 11 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr I Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria lPLV Criteria fiance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity. Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy12 System 12 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr I Component Category Capacity Design Eff Design lPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 9 Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy13 System 13 Constant Volume Packaged No. of Units System 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled 65000 to 135000 13.00 10.30 8.00 PASSES Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy16 System 16 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy17 System 17 Constant Volume Air Cooled No of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria H'LV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume . Air Distribution ADS System 6.00 6.00 PASSES System 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 10.1 J PrOSy18 System IS Constant Volume Air Cooled No. of Units Split System <65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy19 System 19 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled <65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy20 System 20 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity. Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.20 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 PASSES System PrOSy21 System 21 Constant Volume Air Cooled • No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria 1PLV Criteria liance Cooling System Air Cooled <65000 Btu/h 13.00 13.00 8.00 PASSES Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 11 Air Handling Air Handler (Supply) - 0.20 0.90 System -Supply Constant Volume Air Distribution ADS System 6.00 6.00 System PASSES PASSES PASSES - Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV D'LV fiance None Water Heater Compliance DDesign Min Design Max Comp Description Type Category Eff Eff Loss Loss fiance None Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] None 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 12 - Project: Carlton Square Title: Carlton Square Type: Retail (WEA File: DAYTONABEACH.TMY) Other Required Compliance Category Section Requirement (write N/A in boa if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met ❑ System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T & B 410.1 ' Vesting and Balancing will be performed Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge FlaCom attached? 7/6/2007 EnergyGauge FLA/COM 2004 v3.00 13