Loading...
HomeMy WebLinkAboutCHVAC LOADSFILE COP` Harbor Insurance SCANNED HVAC Load Analysis BY for St. Lucie County Harbor Insurance Kitterman Plaza Units 6, 7 & 8 Port St. Lucie, FL v CQLYTR4ERGI H11AC LQAasD$ Prepared By: Eric J. Svoboda, PE Fort Pierce Engineering, Inc. 315 South 7th Street Fort Pierce, FL 34950 772-672-4636 Sunday, December 19, 2010 Chvac- FullCommercial HVAC Loads Calculation Program :�' - Elite Software Development, Inc'. I " A Harbor Insurance j ' Page 2 Building Summary Loads Building peaks in August at gam. Bldg Load Area Sett %Tot Lat Sen Net %Net Descriptions Quan.' _ Loss 'Loss Gain Gain .. Gain Gain Roof 4,578 7,554 13.67 0 3,848 3,848 2.74 Wall 2,709 8,493 15.37 0 3,653 3,653 2.60 Glass 315 8,628 15.62 0 30,881 30,881 21.96 Floor Slab - 189 3,867 7.00 0 0 0 0.00 Skin Loads 28,541 51.66 0 38,382 38,382 27.29 Lighting 9,156 0 0.00 0 31,242 31,242 22.21 Equipment 4,578 0 0.00 0 15,621 15,621 11.11 People 39 0 0.00 7,708 9,635 17,343 12.33 Partition 0 0 0.00 0 0 0 0.00 Cool. Pret. 0 0 0,00 0 0 0 10.00 Heat. Pret. 0 0 0.00 0 0 0 0.00 Cool. Vent. 750 0 0.00 29,602 7,418 37,021 26.32 Heat. Vent. 750 26,706 48.34 0 0 0 0.00 Cool.lnfil. 0 0 0.00 0 0 0 0.00 Heat.Infil. 0 0 0.00 0 0 0 0.00 Draw-Thru Fan 0 0 0.00 0 1,029 1,029 0.73 Blow-Thru Fan 0 0 0.00 0 0 0 0.00 Reserve Cap. 0 0 0.00 0 0 0 0.00 Reheat Cap. 0 0 0.00 0 0 0 0.00 Supply Duct 0 0 0.00 0 0 0 0.00 Return Duct 0 0 0.00 0 0 0 0.00 Misc. Supply 0 0 0.00 0 0 0 0.00 Misc. Return 0 0 0.00 0 0 0 0.00 Building Totals 55,247 100.00 37,310 103,327 140,637 100.00 BuildingSen _ /ooTof Lat 'Sen Net`, %oNet i Summary• Loss Loss Gain _ Gain 1Gain Gain { Ventilation 26,706 48.34 29,602 7,418 37,021 26.32 Infiltration 0 0.00 0 0 0 0.00 Pretreated Air 0 0.00 0 0 0 0.00 Zone Loads 28,541 51.66 7,708 94,880 102,588 72.94 Plenum Loads 0 0.00 0 0 0 0.00 Fan & Duct Loads 0 0.00 0 1,029 1,029 0.73 Building Totals 55.247 100.00 37,310 103,327 140,637 100.00 Check Fi ures Total Building Supply Air (based on a 20° TD): 4,297 CFM Total Building Vent. Air (17.45% of Supply): 750 CFM Total Conditioned Air Space: 4,578 Sq.ft Supply Air Per Unit Area: 0.9387 CFM/Sq.ft Area Per Cooling Capacity: 390.6 Sq.ft/Ton Cooling Capacity Per Area: 0.0026 Tons/Sq.ft Heating Capacity Per Area: 12.07 Btuh/Sq.ft Total Heating Required With Outside Air: 55,247 Btuh Total Cooling Required With Outside Air: 11.72 Tons r C:\Documents and Settings\Eric S\Desktop\Harbor Insurance\HVAC\Harbor Insurance.CHV Sunday, December 19, 2010, 06:31 PM Chvac- FullCommercialHVAC Loads Calculation Program. - - - Elite Software Development, Inca r ` A ce Harbor ln Pane Pae3� Air Handler #1 - RTU 1 - Summary Loads Zn Description Area Htg.Loss Sen.Gain Lat.Gain Htg.O.A. Clg.O.A. No Zone Peak Time People 'Htg.CFM CIg.CFM S.Exh Req.CFM Req.CFM - volume, CFM7S ft CFM/S ft W.Exh Act.CFM Act.CFM 1 Conference 297 4,944 16,718 2,000 Direct Direct 8am August 10 229 692 0 56 56 4,158 0.77 2.33 0 145 131 2 File Area 666 1,523 9,533 888 Direct Direct 3pm August 4 71 395 0 126 126 9,324 0.11 0.59 0 45 75 3 Office 7 72 119 1,017 96 Direct Direct 3pm August 0 6 42 0 14 14 1,008 0.08 0.58 0 3 8 4 Office 8 72 119 1,017 96 Direct Direct 3pm August 0 6 42 0 14 14 1,008 0.08 0.58 0 3 8 5 Break Room 154 1,243 2,545 205 Direct Direct 7pm August 1 58 105 0 29 29 2,156 0.37 0.68 0 36 20 6 Toilet 56 587 1,003 75 Direct Direct 9pm August 0 27 42 0 11 11 784 0.49 0.74 0 17 8 Zone Peak Totals: 1,317 8,533 31,832 3,360 Total Zones: 6 17 395 1,318 0 250 250 Unique Zones: 6 18,438 0.30 1.00 0 250 250 C:\Documents and Settings\Eric S\Desktop\Harbor Insurance\HVAC\Harbor Insurance.CHV Sunday, December 19, 2010, 06:31 PM Chvad• Full Commercial Loads Calculation Program - - Elite Software Develbpment,,lnc. I • APae4! Harbor Insurance i ' Air Handler #1 - RTU 1 - Total Load Summar Air Handler Description: RTU 1 Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.12 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.90 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: gam in August. Outdoor Conditions: 84° DB, 76° WB, 119.72 grains Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 8,533 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 8,902 Btuh 250 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 17,435 Btuh Heating Supply Air: 8,533 / (.999 X 1.08 X 20) = 395 CFM Winter Vent Outside Air (63.2% of supply) = 250 CFM Zone space sensible gain: 30,106 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 316 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 30,421 Btuh Cooling Supply Air: 30,421 / (.999 X 1.1 X 21) = 1,318 CFM Summer Vent Outside Air (19.0% of supply) = 250 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 2,473 Btuh 250 CFM Blow-thru fan sensible gain: 0 Btuh . Total sensible gain on return side of coil: 2,473 Btuh Total sensible gain on air handling system: 32.894 Btuh Zone space latent gain: 3,360 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 9,867 Btuh Total latent gain on air handling system: 13,227 Btuh Total system sensible and latent gain: 46,121 Btuh Check Fi ures Total Air Handler Supply Air (based on a 21 ° TD): 1,318 CFM Total Air Handler Vent. Air (18.97% of Supply): 250 CFM Total Conditioned Air Space: 1,317 Sq.ft Supply Air Per Unit Area: 1.0008 CFM/Sq.ft Area Per Cooling Capacity: 342.7 Sq.ft/Ton Cooling Capacity Per Area: 0.0029 Tons/Sq.ft Heating Capacity Per Area: 13.24 Btuh/Sq.ft Total Heating Required With Outside Air: 17,435 Btuh Total Cooling Required With Outside Air: 3.84 Tons C:\Documents and Settings\Eric S\Desktop\Harbor Insurance\HVAC\Harbor Insurance.CHV Sunday, December 19, 2010, 06:31 PM Chvac- FullCommercial HVAC Loads Calculation Program- ---, - - -' Elite Software Development, Inc. I �, - • 'Harbor'Insurance Air Handler #2 - RTU 2 - Summaty Loads Zn , Description ? .Arbal Htg Loss. Sen.Gain . Lat.Gain Htg.o,A. CIg.O:A No Zone Peak•Tinne• People „•Htg CFM,,, Clg.CFM S.Exh Req.CFM Req.GFM I , Volume =" CFM/S 'k y.- CFM/S ft W.Exh Act.CFM ' _ 'Act.CFM i 7 Spare Office 144 1,594 4,124 192 Direct Direct 9am August 1 74 178 0 22 22 2,016 0.51 1.24 0 41 30 8 Reception 144 2,104 6,221 192 Direct Direct Sam August 1 97 269 0 22 22 2,016 0.68 1.87 0 54 45 9 Office 1 110 1,977 5,780 147 Direct Direct 8am August 1 92 250 0 17 17 1,540 0.83 2.27 0 50 42 10 Work / File Area 980 1,617 13,836 1,307 Direct Direct 3pm August ' 7 75 598 0 148 148 13,720 0.08 0.61 0 41 100 11 Server 121 976 2,000 161 Direct Direct 7pm August 1 45 86 0 18 18 1,694 0.37 0.71 0 25 14 12 Closet / Hall 108 1,026 1,871 144 Direct Direct 9pm August 1 48 81 0 16 16 1,512 0.44 0.75 0 26 13 13 Women 48 503 860 64 Direct Direct 9pm August 0 23 37 0 7 7 672 0.49 0.77 0 13 6 Zone Peak Totals: 1,655 9,797 34,692 2,207 Total Zones: 7 11 454 1,501 0 250 250 Unique Zones: 7 23,170 0.27 0.91 0 250 250 C:\Documents and Settings\Eric S\Desktop\Harbor Insurance\HVAC\Harbor Insurance.CHV Sunday, December 19, 2010, 06:31 PM Chvac - Full IIommercial HVAC Loads Calculation Program:. - - Elite SoftwareDevelopment, Inc.: Harbor Insurance, Page Air Handler #2 - RTU 2 - Total Load Summary Air Handler Description: RTU 2 Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.14 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.94 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 9am in August. Outdoor Conditions: 84° DB, 76° WB, 119.72 grains Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 9,797 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 8,902 Btuh 250 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 18,699 Btuh Heating Supply Air: 9,797 / (.999 X 1.08 X 20) = 454 CFM Winter Vent Outside Air (55.1 % of supply) = 250 CFM Zone space sensible gain: 32,624 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 359 Btuh Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 32,983 Btuh Cooling Supply Air: 32,983 / (.999 X 1.1 X 20) = 1,501 CFM Summer Vent Outside Air (16.7% of supply) = 250 CFM Return duct sensible gain: 0 Stuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 2,473 Btuh 250 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 2,473 Btuh Total sensible gain on air handling system: 35,456 Btuh Zone space latent gain: 2,207 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 9,867 Btuh Total latent gain on air handling system: _ 12,074 Btuh Total system sensible and latent gain: 47,530 Btuh Eheck Fi Gres ,__ .. • , e ._ ... „... ;, Total Air Handler Supply Air (based on a 200 TD): 1,501 CFM Total Air Handler Vent. Air (16.66% of Supply): 250 CFM Total Conditioned Air Space: 1,655 Sq.ft Supply Air Per Unit Area: 0.9067 CFM/Sq.ft Area Per Cooling Capacity: 417.8 Sq.ft/Ton Cooling Capacity Per Area: 0.0024 Tons/Sq.ft Heating Capacity Per Area: 11.30 Btuh/Sq.ft Total Heating Required With Outside Air: 18,699 Btuh Total Cooling Required With Outside Air: 3.96 Tons C:\Documents and Settings\Eric S\Desktop\Harbor Insurance\HVAC\Harbor lnsurance.CHV Sunday, December 19, 2010, 06:31 PM Chvac - Full Commercial HVAC'Loads Calculation Program --- - Elite Software Development, Inc. Harbor Insurance ' `-'- Pace,7 Air Handler #3 - RTU 3 - Summary Loads Zn Description Area Htg Loss Sen.Gain Lat.Gain Htg.O.A Clg.O.A. No . Zone Peak Time Htg.CFM Cl9.CFM S.Exh Req.CFM Req.CFM 'Peopler Volume CFM/S ft_ CFM/Soft W.Exh ACt.CFM Act.CFM 14 Men 48 503 860 64 Direct Direct 9pm August 0 23 37 0 7 7 - 672 0.49 0.77 0 12 6 15 Office 2 110 1,977 5,780 147 Direct Direct Sam August 1 92 249 0 17 17 1,540 0.83 2.27 0 48 42 16 Office 3 110 107 5,780 147 Direct Direct Sam August 1 92 249 0 17 17 1,540 0.83 2.27 0 48 42 17 Office 4 110 1,468 3,680 147 Direct Direct Sam August 1 68 159 0 17 17 1.540 0.62 1.44 0 36 27 18 Hall 114 188 1,610 152 Direct Direct 3pm August 1 9 69 0 18 18 1,596 0.08 0.61 0 5 12 19 Work Area 150 248 2,118 200 Direct Direct 3pm August 1 11 91 0 23 23 2,100 0.08 0.61 0 6 15 20 File Area 120 198 1,694 160 Direct Direct 3pm August 1 9 73 0 19 19 1,680 0.08 0.61 0 5 12 21 Hall 114 188 1,610 152 Direct Direct 3pm August 1 9 69 0 18 18 1,596. 0.08 0.61 0 5 12 22 Work / File Area 378 624 5,337 504 Direct Direct 3pm August 3 29 230 0 59 59 5,292 0.08 0.61 0 15 39 23 Rear Hall 110 888 1,818 147 Direct Direct 7pm August 1 41 78 0 17 17 1,540 0.37 0.71 0 22 13 24 Office 5 121 976 2,000 161 Direct Direct 7pm August 1 45 86 0 19 19 1,694 0.37 0.71 0 24 15 25 Office 6 121 976 2,000 161 Direct Direct 7pm August 1 45 86 0 19 19 1,694 0.37 0.71 0 24 15 Zone Peak Totals: 1,606 10,211 34,285 2,141 Total Zones: 12 11 473 1,479 0 250 250 Unique Zones: 12 22,484 0.29 0.92 0 250 250 C:\Documenls and Settings\Eric S\Desktop\Harbor Insurance\HVAC\Harbor Insurance.CHV Sunday, December 19, 2010, 06:31 PM Chvac -Full Commercial HVAC,Loads Calculation Program Elite Software Development, Inc. - Harbor Insurance I ` ' - Page 8 Air Handler #3 - RTU 3 - Total Load Summary Air Handler Description: RTU 3 Constant Volume - Proportion Supply Air Fan: Draw-Thru with program estimated horsepower of 0.14 HP Fan Input: 0% motor and fan efficiency with 0 in. water across the fan Sensible Heat Ratio: 0.94 --- This system occurs 1 time(s) in the building. --- Air System Peak Time: 9am in August. Outdoor Conditions: 84° DB, 76° WB, 119.72 grains Summer: Ventilation controls outside air, ----- Winter: Ventilation controls outside air. Zone Space sensible loss: 10,211 Btuh Infiltration sensible loss: 0 Btuh 0 CFM Outside Air sensible loss: 8,902 Btuh 250 CFM Supply Duct sensible loss: 0 Btuh Return Duct sensible loss: 0 Btuh Return Plenum sensible loss: 0 Btuh Total System sensible loss: 19,113 Btuh Heating Supply Air: 10,2111 (.999 X 1.08 X 20) = 473 CFM Winter Vent Outside Air (52.8% of supply) = 250 CFM Zone space sensible gain: 32,150 Btuh Infiltration sensible gain: 0 Btuh Draw-thru fan sensible gain: 354 Btuh - Supply duct sensible gain: 0 Btuh Reserve sensible gain: 0 Btuh Total sensible gain on supply side of coil: 32,504 Btuh Cooling Supply Air: 32,504 / (.999 X 1.1 X 20) = 1,479 CFM Summer Vent Outside Air (16.9% of supply) = 250 CFM Return duct sensible gain: 0 Btuh Return plenum sensible gain: 0 Btuh Outside air sensible gain: 2,473 Btuh 250 CFM Blow-thru fan sensible gain: 0 Btuh Total sensible gain on return side of coil: 2,473 Btuh Total sensible gain on air handling system: 34,977 Btuh Zone space latent gain: 2,141 Btuh Infiltration latent gain: 0 Btuh Outside air latent gain: 9,867 Btuh Total latent gain on air handling system: 12,009 Btuh Total system sensible and latent gain: 46,986 Btuh CheckFi ure5 Total Air Handler Supply Air (based on a 200 TD): 1,479 CFM Total Air Handler Vent. Air (16.91 % of Supply): 250 CFM Total Conditioned Air Space: 1,606 Sq.ft Supply Air Per Unit Area: 0.9208 CFM/Sq.ft Area Per Cooling Capacity: 410.2 Sq.ft/Ton Cooling Capacity Per Area: 0.0024 Tons/Sq.ft Heating Capacity Per Area: 11.90 Btuh/Sq.ft Total Heating Required With Outside Air: 19,113 Btuh Total Cooling Required With Outside Air: 3.92 Tons C:\Documents and Settings\Eric S\Desktop\Harbor Insurance\HVAC\Harbor lnsurance.CHV Sunday, December 19, 2010, 06:31 PM Construction Florida Department' of Commu'nfty Affairs €nergyG'auge' Summits Fla/Com-2008, Effective;. March 1, 2000 -- Form 40OA-2008 Method -A -Whole Build! nd,'Perfdrmance, Method,,for Commercial Buildings PROJECT SUMMARY OLANIV1--D BY St. Luria CountV Short Desc: Harbor Insurance Description: Harbor Insurance Owner: Harbor Insurance Address]: Kitterman Plaza Units 6, 7 & 8 City: Port St. Lucie Address2: State: FL Zip: 0 Type: Office Class: New Finished building Jurisdiction: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) Conditioned Area: 4560 SF Conditioned & UnConditioned Area: No ofStories: 1 Area entered from Plans Permit No: 0 Max Tonnage If different, write in: 4560 SF 0 SF 4 �uuunq %% N �: 8 882 o a STA E OF :•Q. EnergyGauge Summit@ Fla/Com-2008. Effective: March 1, 2009 12/19/2010 Page I of 7 Compliance Summa Component Design Criteria Result Gross Energy Cost (in $) 3,192.0 3,397.0 PASSED LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES None Entered PASSES None Entered None Entered None Entered Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit@ Fla1Com-2008. Effective: March 1, 2009 12/19/2010 Page 2 of 7 CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation -are in compliance with the Florida Energy Code Prepared By: Eric J. voboda, PE Building Official: Date: 17 o -oo Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (') that the system design is in compliance with the FLorida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: Reg No: Plumbing Designer: - Reg No: (') Signature is required where Florida Law requires design to be performed by registered design professionals. EnergyGauge Summil0 Fla/Com-2008. Effective: March 1, 2009 12/19/2010 Page 3 of 7 Project: Harbor Insurance Title: Harbor Insurance Type: Office (WEA File: FL ST LUCII Building End Uses 1) Proposed 2) Baseline Total 205.40 255.40 $3,192 $3,996 ELECTRICITY(MBtulkWh/$) 205.40 255.40 60226 74830 $3,192 $3,996 AREA LIGHTS 49.10 52.40 14394 15362 S763 S820 MISC EQUIPMT 68.40 68.40 20043 20043 $1,062 $1,070 PUMPS & MISC 0.00 0.10 13 21 $1 $1 SPACE COOL 67.40 66.00 19762 19326 $1,047 $1,032 SPACE HEAT 0.50 3.70 151 1080 $8 $58 VENT FANS 20.00 64.80 5863 18998 $311 $1,014 assing requires Proposed Building cost to be at most 85% PASSES f Baseline cost. This Proposed Building is at 79.9% EnergyGauge Summit@ Fla/Com-2008. Effective: March 1. 2009 12/19/2010 Page 4 of 7 External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None Project: Harbor Insurance Title: Harbor Insurance Type: Office (WEA File: FL_ST LUCIE CO_INTL.tm3) .Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance PrOZolSpl 17 Office -Enclosed 4,560 20 2 PASSES PASSES Project: Harbor Insurance Title: Harbor Insurance Type: Office (WEA File: FL_ST_LUCIE_CO_INTL.tm3) System Report Compliance 1Pr0Sy1 System 1 Constant Volume Packaged No. of Units System 3 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Conditioners Air Cooled 13.00 12.23 8.00 PASSES < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 0.30 0.90 PASSES System -Supply Constant Volume Air Distribution ADS System 6.00 3.50 PASSES System PASSES EnergyGauge Summit@ Fla/Com-2008. Effective: March 1, 2009 12/19/2010 Page 5 of 7 Plant Compliance Description Installed Size Design Min Design Min Category No Eff Eff IPLV IPLV Comp Hance None Water Heater Compliance Description Type Category Design Min Design Eff Eff Loss Max Comp Loss Hance None Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins jinchesj Runout? Temp [Btu-in/hr Thick jinj jFj SF.Fj Req Ins Compliance Thick linj None EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009 12/19/2010 Page 6 of 7 A: Harbor Insurance Harborinsurance Office File: FL_ST_LUCIE_CO_INTL.tm3) Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Report 13-101 Input Report Print -Out from EnergyGauge FlaCom attached Operations Manual 13-102.1, Operations manual provided to owner 13-410,13-413 Windows & Doors 13-406.AB. 1. 1 Glazed swinging entrance & revolving doors: max. 1.0 cfm/ft'; all other products: 0.4 cfm/ft' Joints/Cracks 13-406.AB.1.2 To be caulked, gasketed, weather-stripped or otherwise sealed Dropped Ceiling 13-406.AB.3 Vented: seal & insulated ceiling. Unvented seal & insulate roof & ❑ Cavity side walls System 13-407 HVAC Load sizing has been performed ❑ Reheat 13-407.13 Electric resistance reheat prohibited El HVAC Efficiency 13-407, 13-408 Minimum efficiences: Cooling Tables 13-407.AB.3.2.1A-D; ❑ Heating Tables 13-407.AB.3.2.1B, 13-407.AB.3.2. I D, 13-408.AB.3.2.1E, 13-408.AB.3.2F HVAC Controls 13-407.AB.2 Zone controls prevent reheat (exceptions); simultaneous heating and cooling in each zone; combined HAC deadband of at least 57 (exceptions) Ventilation Controls 13-409.AB.3 Motorized dampers reqd, except gravity dampers OK in: 1) ❑ exhaust systems and 2) systems with design outside air intake or exhaust capacity <300 cfm ADS 13-410 Duct sizing and Design have been performed ❑ HVAC Ducts 13-410.AB Air ducts, fittings, mechanical equipment & plenum chambers ❑ shall be mechanically attached, sealed, insulated & installed per Sec. 13-410 Air Distribution Systems Balancing 13-410.ABA HVAC distribution system(s) tested & balanced. Report in construction documents Piping Insulation 13-41 LAB In accordance with Table 13-41 LAB.2 Water Heaters 13-412.AB Performance requirements in accordance with Table 13-412.AB.3. Heat trap required Swimming Pools 13-412.AB.2.6 Cover on heated swimming pools: Time switch (exceptions); ❑ Readily accessible on/off switch Hot Water Pipe 13-41 LAB.3 Table 13-41 LAB.2 for circulating systems, first 8 feet of outlet Insulation pipe from storage tank and between inlet pipe and heat trap Water Fixtures 13-412.AB.2.5 Shower hot water flow restricted to 2.5 gpm at 80 psi. Public lavatory fixture how water flow 0.5 gpm max; if self -closing valve 0.25 gallon recirculating, 0.5 gallon non recirculating Motors 13-414 Motor efficiency criteria have been met Lighting Controls 13-415.AB Automatic control required for interior lighting in buildings >5,000 s.f; Space control; Exterior photo sensor; Tandom wiring with 1 or 3 linear fluuorescent lamps>30W EnergyGauge Summit0 Fla/Com-2008. Effective: March 1, 2009 12/19/2010 Page 7 of 7 EnergyGauge Summit® v3.22 INPUT DATA REPORT Proiect Information Project Name: Harbor Insurance Project Title: Harbor Insurance Address: Kitterman Plaza Units 6, 7 & 8 State: FL Zip: 0 Owner: Harbor Insurance Orientation: North Building Type: Office Building Classification: New Finished building No.of Stories: I GrossArea: 4560 SF Zones No Acronym Description Type Area Multiplier [sq Total Area [sf] 1 PrOZoI Zone I CONDITIONED 4566.0 I 4560.0 ❑ Spaces No Acronym Description Type Depth Width A [ftl Height Multi Total Area [ftl plier [sfI Total Volume tcfl 12/19/2010 EnergyGauge Summit@ v3.22 In Zone: PrOZol 1 PrOZoISPI ZoOSPI Office - Enclosed 48.00 95.00 14.00 1 4560.0 63840.0 ❑ Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W]l Ctrl pts In Zone: Pr0Zo1' In Space: PrOZo1Sp1 1 Compact Fluorescent General Lighting 1 4700 4700 Manual On/Off 20 ❑ Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ftl [ftl plier [sf] [Btu/hr. sf F] Capacity [lb/cf] [h.sf.F/Btul [Btu/sf.Fl In Zone: PrOZol l PrOZOI Wa1 5/8" stucco 95.00 14.00 l 1330.0 East 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZol Wag 5/8" stucco 95.00 14.00 1 1330.0 West 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp Windows No Description Type Shaded U SHGC Vis.Tra W H (Effec) Multi Total Area [Btu/br sf Fl [ft] [ft] plier [s fl In Zone: PrOZol In Wall: East I Pr0Zo 1 Wa l W i 1 User Defined No 1.2500 0.82 0.76 3.00 7.00 16 336.0 EEJI 12/19/2010 EnergyGauge Summit® v3.22 Doors No Description Type .Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] [Ib/ct] [Btu/sE F] [h.sf.FBtul In Zone: PrOZo1 In Wall: West I PrOZol Wa2Drl Solid core flush No 3.00 7.00 3 21.0 0.3504 0.00 0.00 2.85 ❑ (2.25) Roofs No Description Type Width H (Effec) Multi Area " Tilt Cond. Heat Cap Dens. R-Value IN N plier [sl] [deg] [Btu/hr. SE F] [Btu/sE F] [Ib/ct] [h.sEF/Btu] In Zone: PrOZoI I PCOZOIRfl Mtl Bldg Roof/R-19 95.00 48.00 1 4560.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt Skylights No Description Type U SHGC Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] [ft] [ft] [Sf] [Sf] In Zone: In Roof: Floors No Description Type. Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sE F] [Btu/sE F] [lb/cf] [h.sEF/Btu] In one: PrOZol I PrOZOI Fl l I ft. soil, concrete 95.00 48.00 1 4560.0 0.2681 34.00 113.33 3.73 ❑ floor, carpet and rubber pad 12/19/2010 EnergyGauge Summit® v3.22 Systems 1Pr0Sy1 System 1 Constant Volume Packaged, System No. Of Units 3 Component Category Capacity Efficiency IPLV I Cooling System 2 Heating System 3 Air (Handling System -Supply 4 Air Distribution System 48000.00 24000.00 1440.00 13.00 8.00 1.00 0.30 6.00 ❑ ❑ Plant Equipment Category . Size Inst.No Eff. IPLV El Water Heaters W-Heater Description CapacigCap.Unit I/P Rt. Efficiency Loss El Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sVft/No] [W] 12/19/2010 EnergyGauge Summit® v3.22 Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness (F[ [ Btu-in/h.sf.F[ [in[ [in[ uJ Fenestration Used Name Glass Type No. of Glass SHGC VLT Conductance Panes [Btu/h.sf.F[ ASHULSgICIrAI User Defined 1 1.2500 0.8200 0.7600 ❑ IFrm Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sf.F/Btuj IN lBtu/h.ft.F[ [Ib/ct] [Btu/Ib.FJ 187 MatII87 6YP OR PLAS No . BOARD,1 /2IN 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Matl265 Soil, I fl No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 268 Mat1268 0.625"stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 1 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.MOO ❑ 23 Matl23 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/8IN 12/19/2010 1 EnergyGauge Summit® v3.22 5 Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.Fl lBtu/sfF) lib/cfl [h.sf.FBtu) 1011 5/8" stucco /8"CMU/3/4"ISO No No 0.21 5.73 34.65 4.8 ❑ BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. [ft] Factor 1 268 0.625" stucco 0.0521 0.000 ❑ 2 42 8 in. Lightweight concrete block. 0.6670 0.000 ❑ 3 269 .75" ISO BTWN24" oc 0.0625 0.000 ❑ 4I 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cfl [h.sf.FBtul 1056 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 ❑ Layer Material Material Thickness Framing No. [ft) Factor 1 94 BUILT-UP ROOFING, 3/8IN 0.0313 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 ❑ No Name Simple Massless - Conductance Heat Capacity Density RValue Construct Construct lBtu/h.sf.Fl [Btu/sf.Fl [Ib/cfl [h.sf.F/Btul 1057 1 ft. soil, concrete floor, carpet and rubber No No 0.27 34.00 113.33 3.7 ❑ pad Layer Material Material Thickness Framing - No. lftl Factor 1 265 Soil, I ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ 12/19/2010 EnergyGauge Summit@ v3.22 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] jh.sf.FBtu[ 1058 Solid core flush (2.25) No Yes 0.35 2.9 ❑ Layer Material Material Thickness Framing No. (f[j Factor 1 279 Solid core flush (2.25") 0.000 ❑ 12/19/2010 EnergyGauge Summit@ v3.22