Loading...
HomeMy WebLinkAboutENGINEERING PAPERWORKPRINCIPAL Engineering 1011 N Causeway Blvd, Suite 19 ♦ Mandeville, Louisiana 70471 ♦ Phone: 985.624.5001 ♦ Fax: 985.624.5303 April 2019 RECEIVED St. Lucie County APR 2 b 2019 Property Owner: Theresa Berry ST. Lucie County, Permitting SCANNED Property Address: 8606 Penny Lane, Fort Pierce, Florida 34951 BY St. Lucie County Re: HIGH WIND -RESISTANT CONSTRUCTION CERTIFICATE Wind loads have been calculated for a speed of 157 MPH. The roof pitch and construction have been analyzed, and the photovoltaic system structure designed to resist resulting uplift and downward forces. The attached drawings and diagrams reflect a design that safely transmits dead and live loads to the roof. To the best of my professional knowledge and belief, the subject construction and photovoltaic system installation will be in compliance and designed to 2017 Florida Building Code 6d Edition at the time of our review. PERMIT SET I�gq614-OL3 Z- REVIEWED FOR CODE COMPLIANCE ST. LUCIE C( BOCC * No. 71950 .* Vf W� n �4. STATE OF 4/; Firm No. 30649 Principal Engineering, Inc. PRINCIPAL Infrastructure T M FILE Copy Architecture ♦ Engineering ♦ Construction www.pi-aec.com ♦ info@pi-aec.com Uplift and Wind Downforce Calculation Summary (ASCE 7-05 Method 1) Mount, Rack, & Panel Proportioning Property Owner: Theresa Berry Individual Panel Dimensions Project Address: 18606 Penny Lane Length (in) Width (in) Area (s City, State: IFort Pierce, Florida 34951 77 1 39 20.85 Building Characteristics, Design Input, and Adjustment Factors Basic Wind Speed: Exposure Category: Occupancy Category: Effective Wind Area (sf): Roof Dimensions: Length: Width: Roof Height (h): Pitch: on 12 = Ht. & Exposure justment (A) Importance Factor (1) TopographicAdj. (Kt) 157 From Code Office or Fig. 6-1 Para 6.5.6.3 Table 1-1 Para 6.2 (Area per individual fastener) Least Dimension: 34 Fig 6-3, Note 5, must be less than 60 degrees; must be less than 45 Fig. 6-3 Table 6-1 Para 6.5.7 B 2 10 54 34 15 18.4 1 1 1 Roof Zone Strip (a), in ft,, Fig. 6-3, Note 5 _ 1- Least Roof Horizontal Dimension (L or W) x 0.10 2 - Roof Height x 0.4 3 - Least Roof Horizontal Dimension (L or W) x 0.04 4 - Least of (1) and (2) 5 - Greater of (3) and (4) 6 - Greater of (5) and 3 feet a= 3.4 6 1.36 3.4 3.4 3.4 RECEIVED APR 2 5 201.9 Lucie County, Permitting ` va''4A ��GENgF No.71950 STATE OF Net Design Pressures (Fig 6-3), Components & Cladding Zone 1 Zone 2 Zone 3 Uplift (-psf) Down (psf) Interior Roof Area Strip of (a) ft wide at root edge Corner intersection of strips 30net lArinr3onet 30net rt 30net 40.7 40.7 25.6 25.6 70.9 70.9 25.6 25.6 104.9 104.9 25.6 25.6 Mount& Rail Selection Manufacturer: Model: Ultimate Uplift (lb): Nucor Perpindicular Panel Orientation S-5-1.1 Mini Allowable Scheme by Uplift Pressure 1913 < 60 psf 2 rails, 4"-0" OC mounts 60-90 psf 3 rails, 4'-0"; or 2 rails, 2'-0" 90-110 psf 4 rails, 4"-0" OC mounts 110-150 psf 3 rails, 2'-0" OC mounts 150-170 psf 4 rails, 2'-0" OC mounts 1170 psf+, panel clip capacity exceeded Parallel: Mounts per Individual Panel # Mounts FS Zone 1 1.5 3.4 Zone 2 3.3 4.3 Zone 3 3.3 2.9 (From rail analysis, allowable pressures controlled by individual mount pullout before rail bending) Firm No. 30649 Principal Engineering, Inc. cnvedopn lu:¢ueeayn-moa-vl.�e-ogca�luooioovult Install Map as Theresa Berry Quantity: 16 Panel: JA 300 Inverter: Enphase iQ7 The engineer's seal and signature on this manufacturer's drawing certifies the product for use in this project only. Estimated Energy Savings Annual Results 7,166 kWh per Year' I -my High Estimated Solar Energy Production tknvnrpr 6,866 7,466 Estimated Energypro Efficiency Savings tkvnwyr- 2,000 6,000 Solar+ Energypro Estimated Annual Benefit tlrwhml 8,866 13,466 Monthly Estimates lkwmmao " 492 701 'rhe solarenerey peoducton provided here to onlym estlmale and does not take Intoaccuunl enypre4nabnR charter rasues.The final Radar energy production guarealee yM he iaaued altar thejob is complete and Wood entire, shade mensuremente mnduded al lbeday et installation. " oceans Iram Neenelgy siy wotkmodueled by Ece,gypm are eadrmlen Doty and cannot W guaranteed ea every home utigreo d'dhrent mmon.1nalruNon meNodv. Estimated Monthly Production ergo - -- — -- ------ - - --- - 0 Z SB No. I e- UNFOMMN OaremayOks OR Sor PE5oUsn TO Es APPROVAEa rand HOMEOWNER V or r� Firm Print Il The a Berry APPROVE THE PROPOSED DESIGN AND ESTIMA" ENERGY SAVINGS FOR MY SOLAR PANEL INSTALLATION. UoouSignedby: X E AgAa 506C c v M o n b* rn < J�. 30649 Al Engine ring, Inc. MARCJONES Install: CONSTRUCTION residential -commercial • set or S U N �R SOS RNbid S C1kW$TS • . t__J � t JurlShc Utility: Desigr Date: STATE OF Lane, Fort Pierce, FL 34951 4.80 kW Solar Panel Sy St. Lucie County FP&L Z Olmstead 04.15.19 1 REV: 1 1 Sheet: 1 of 1 THIS EDGE TOWARDS ROOF RIDGE The engineer's seal and signature on this manufacturer's drawing a the product for use in this project 4.50 • tt Hrm NO. DESCRIPTION QTY. 1 FLASHING, ROUNDED CORNERS, 9" X 12" X .040", 5052, MILL 1 2 L-FOOT, 2" X 3.30" FOR .438" O.D. FASTENER, 6061-T6/6005A-T61, MILL 1 3 WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS 1 4 LAG SCREW, HEX HEAD, 5/16" x 4", 18-8 SS 1 L-FOOT 2" X 3.30", 2 X .75" SLOT FOR .438" O.D. FASTENER, 6061- r,,,,.,,�. _11 —.11 12.00 4 QMLM2: R,i4..r,, 2 X .75" SLOT { `_ DtFRAiyc+,�+ VERSION QY.� * OPTIONAL- 3 4.20) _ * no. 71950 e 3.00 W� STATE OF ? 1 o 2.00 0.397W1.77 � RR 23.30r{ .90 u 2.00 0.397 TYP 1.00 .p N o 1 3 io irm No. 30649 3.30 Principal Engin -rdD l .75 O AVAILABLE IN MILL, AND BLACK FINISHES .25 1.14 75 C uick Mount PV� TITLE: Theresa LM2 QMLM: L-MOUNT, 5/16" LAG, 9" X 12" FLASHING 8606 Penny Lane QMLM UNLESS OTHERWISE SPECIFIED: SIZE DRAWN BY: RAID REV Fort Pierce, Florida 34951 DIMENAONS: IN INCHES A 6 1RACTIONAFL2118 DATE: 8/23/2017 WTH6DMWWG6THESOLEPROPERIYOFOUCKMOUMW. ANYREPRODUCTONNPAWORASAWHOLEWRHOWME DONOTSCALE DRAWING I TWOPLACEDECIMAL t.19 THREE PLACE DECIMAL i.094 ISCALE:1:4 WEIGHT: 1.0241 1 SHEET OF MoUMW6PFON199ED. COPYRIGHT 02016 QUICK MOUNT PV 5 4 3 2 1 Installation Address: 8606 Penny Lane, Fort Pierce, Florida 34951 The following components installed per the attached diagrams and plans will comply with the required 157 mph ultimate wind loads in City of St. Lucie. See attached plans labeled as follows; Quick Mount PV, L-Foot Layout, Rail Layout, Solar array Layout. Code Compliant Unirac Solar Installation Components. Unirac SolarMount Rail Components The engineer's seal and signature RECEIVED APR 2 5 2019 ST. Lucie County, Permitting on this manufacturer's drawing certifies Figured. SolarMount standard rail components. the product for use in this project only. ORail —Supports PV modules. Use two per row of lock washer for attaching Lrfoot. Flashings: Use one per modules. Aluminum extrusion, anodized. standoff. Unirac offers appropriate flashings for both standoff types. © Rail splice —Joins and aligns rail sections into single length of mil. It can form either a rigid or thermal expansionjoint, 8 inches long, predrilled. Aluminum extrusion, anodized. © Self -drilling screw —(No. 10 x 3/a") — Use4 per rigid splice or 2 per expansion joint. Galvanized steel. OL-foot— Use to secure rails either through roofing material to building structure or standoffs. Refer to loading tables for spacing. Note: Please contact Unirac for use and specification of double Lrfoot. © L-foot bolt (3/8" x 3/a") —Use one per L-foot to secure rail to 1-foot. Stainless steel. OFlange nut (3/8") — Use one per L-foot to secure rail to Irfoot. Stainless steel. 0 Lag screw for L-foot (5/16") — Attaches standoff to rafter. See PV Quickmount Notes below. 16 Top Mounting Clamps • Top Mounting Grounding Clips and Lugs ADMONAL NOTES: PVOUICKMOUNT—Attaches Lrfootorstandoff to rafter. install per attached Quickmount PV detail; QMSC: Classic composition mount dated 7/19/2012. If lag screw head is exposed to elements, use stainless steel. Under flashings, zinc plated hardware is adequate. Waterproof roofing sealant —Use a sealant appropriate to your roofing material. Consult with the company tkD;Fk" ntlf providing warranty of roofing. O yIGENs� ,� a No. 71950 �* * >< Ix= FILE C®Fy W., STATE OF � _fy! Firm No. 30649 Principal Engineering, Inc.