HomeMy WebLinkAboutENGINEERING PAPERWORKCB Engineering Services, INC. Ed 200 NE 12 Avenue, Unit 6D, Hallandale Beach, FL. 33009 Phone: 954-534-1612 Email: cbbortesno-amail.com To: Fort Pierce Building and Code Regulation Division RECEIVED Fort Virginia Avenue Fort Pierce;fL 34982 APR 2 5 2019 Re: Wind Load -Pressure Computation LE. LUCI® 10211 Isles of Pine Court Port Saint Lucie, FL SCANNED BY St. Lucie County Pursuant to the request of the Stuart Roofing I, the undersigned have performed a wind pressure analysis for the roof as per ASCE 7-16, in order to determine the most critical values at above mentioned location Wind Load -Pressure Computation Results are as follows: Roof Field 25.62 psf -52.32 psf Roof Perimeter 25.62 psf -63.72 psf Roof Corners 46.98 psf-116.38 psf Attached are the calculation results using MecaWind v2323 per ASCE 7-16 software, Design .Method with a load factor of 1. Should you have any questions regarding the above, or if require additional information, please do not hesitate to contact this office. "Engineer seal is valid for pages 1 through 2". Sincerely, CB Engineering Services, INC. (CA # 30935) Signed by: Constantin Bortes M.S., P.E. Florida P.E. # 77915 Date: April 18, 2019 \` OCR.•' UCENSF • �.p� 0.77915 : N _*:� — ' Q •' STATE OF AL l9 oq�b33 REVIEWED FOR CODE COMPLIANCE ST. LUCGE COUNTY BOCCE Contractor Copy Pagel OF 2 MecaWind v2323 :v .:.>✓e:: t'kic.1 6r tesrr:. ". nc., www.meca.biz cy._l- is 1�?18 Calculations Prepared by Calculations Prepared For: Client: STUART ROOFING Date: Apr 18, 2019 Project #: 41819 Designer: CB Engineering Services Inc Location:10208 Isles of Pines Ct. Port Saint Lucie, FL Description: Wind load pressure calculation Basic Wind Parameters Wind Load Standard = ASCE 7-16 Exposure Category - C Wind Design Speed = 170.0 mph Risk Category = II Structure Type = Building Building Type - Enclosed Building Inputs RoofType: Building Roof Type = Hipped Hipped - W Width Perp to Ridge = 35.000 ft L Length Along Ridge = 30.000 it EHt Eave Height = 8.000 ft Hip Ridge Hipped Length - 15.000 ft RE Roof Entry Method = Slope Slope Slope of Roof - 6.0 :12 OR Specify Roof to Wall intersection and Overhang= None Theta Roof Slope = 26.57 Deg Par Is there a Parapet = False ON ALL : None - 0.000 ft Components and Cladding (C&C) Calculations per Ch 30 Part 1: h = Mean Roof Height above grade = 12.375 ft Kh = Z < 15 ft [4.572 m]--> (2.01 * (15/zg)^(2/Alpha) {Table 26.10-1)- 0.849 Kzt = Topographic Factor is 1 since no Topographic feature specified = 1.000 Kd = Wind Directionality Factor per Table 26.6-1 - 0.85 GCPi = Ref Table 26.13-1 for Enclosed Building - +/-0.18 LF = Load Factor based upon STRENGTH Design - 1.00 qh = (0.00256 * Kh * Kzt * Kd * Ke * V^2) * LF = 53.38 psf LHD = Least Horizontal Dimension: Min(B, L) = 30.000 ft al = Min(0.1 * LHD, 0.4 * h = 3.000 ft a = Max(al, 0.04 * LHD, 3 ft [0.9 m]) = 3.000 ft h/B = Ratio of mean roof height to least hor dim: h / B = 0.413 Wind Pressures for C&C Ch 30 Pt 1 All wind pressures include a load factor of 1.0 Description Zone Width Span Area 1/3 Ref GCp GCp p p Rule Fig Max Min Max Min ft ft ft sq ft psf psf --------------- ---- - ------ ____ _______ ----- ------ _____ ------- ROOF FIELD 1 7.500 24.000 192.00 Yes 30.3-2G 0.300 -0.800 25.62 -52.32 ROOF PERIMETER 2r 3.000 24.000 192.00 Yes 30.3-2G 0.300 -1.014 25.62 -63.72 ROOF CORNERS 3 3.000 3.000 9.00 No 30.3-2G 0.700 -2.000 46.98-116.38 Area - Span Length x Effective Width 1/3 Rule = Effective width need not be less than 1/3 of the span length GCp = External Pressure Coefficients taken from Figures 30.3-1 through 30.3-7 p = Wind Pressure: qh*(GCp - GCpi) (Eqn 30.3-1]* Per Para 30.2.2 the Minimum Pressure for CSC is 16.00 psf [0.766 kPa] (Includes LF) Page2 OF 2 0 To: Client: CB Engineering Services, INC. Ea 200 NE 12 Avenue, Unit 6D, Hallandale, FL 33009 Phone: 954-534-1612 Email: cbbortes@gmail.com Fort Pierce Building and Code Regulation Division Stuart Roofing Re: Miami -Dade County HVHZ Electronic Roof Permit Form Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations per RAS 127" Location: 10211 Isles of Pines Court Port Saint Lucie, FL I, the undersigned, perform the Tile Calculation according with Miami Dade County HVHZ requirements using Method 1 "Moment Base Tile Calculation per RAS 127" Conservative Design Wind Uplift Pressures using MecaWind v2323: P1 in Roof Field Area = 52.32 psf P2 in Roof Perimeter Area = 63.72 psf P3 in Roof Corners Area = 116.38 psf Calculation Results Shows the Minimum Resisting Moment for the location mentioned above to be: (calculation sheet is attached to complete the report) RESULTS Mri in Roof Field Area = 9.32 ft-Ibf <_ NOA Mf 45.00 ft-Ibf PASS Mr2 in Roof Perimeter Area = 12.91 ft-Ibf 5 NOA Mf 45.00 ft-Ibf PASS Mr3 in Roof Corners Area = 29.50 ft-Ibf 5 NOA Mf 45.00 ft-Ibf PASS Installation Recommendation From FL#28328 Aerodynamic Multipliers l = 0.315 cuft Restoring Moments due to Gravity Mg = 7.16 ft-Ibf For Slope Adhesive Set System Mf = 45.00 ft-Ibf Total Mf = 45.00 ft-Ibf Pagel OF 2 ® CB Engineering Services, INC. 200 NE 12 Avenue, Unit 6D, Hallandale, Fl. 33009 Phone: 954-534-1612 Email: cbbortes@gmail.com If the Tiles will be attached on the Direct Deck (min 15/32" plywood) with DAP Foam Inc Touch N Seal Storm Bond 2 Two Component NOA 17-0829.12 (1) one Paddy with Average Paddy Weight of 24 grams, the tiles will meet the RAS 127, Current Miami Dade County HVHZ and 2017 Florida Building Code Requirements. "Engineer seal is valid for pages 1 through 2". Should you have any questions regarding the above, or if require additional information, please do not hesitate to contact this office. Sincerely, CB Engineering Services, INC. (CA # 30935) Signed by: Constantin Bortes M.S., P.E. Florida P.E. # 77915 Date: 4/18/2019 TIN .� � ENS ec)n1 R U: No.77915 (P d STATE OF k/ . Paget OF 2