HomeMy WebLinkAboutCARPORT PLANSI
0
RO4L—UP
DOOR
NOTES:
.I I
PLAN VIEW
2.5" BUILDING FRAMING
RECESS
4'
I UOOR WIDTi7-1
ELEVATION VIEW
BUILDING FRAMING
' RECESS
.75•J 14" DOOR WIDTH —
ROLL —UP DOOR CONCRETE
SPLASH —GUARD RECESS
2,500 PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER
MESH) AND 12"x12" REINFORCED FOOTER PERIMETER
SUB —GRADE SOILS:
—TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2017 FLORIDA
BUILDING CODE, 6TH EDITION
CONCRETE:
—MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS
—ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE
STRUCTURE
}"K5}" EXPANSION ANCHOR WITHIN 6" OF
EACH POST/TRUSS ALONG SIDES AND
EVERY OTHER END -WALL POST
2" MIN. - -- BASE -
GRADE _Ed II
1.�.
III --III < a 2.500 PSI 4" CONCRETE
SLAB WITH W.W.F. OR
FIBER MESH
�12"
(2) #5 REBAR ® 6" O.C.
[CAPACITY
IMUM SOIL BEARING CONTINUOUS WITH MINIMUM
2,000 PSF (TP.) 12" OVERLAP SPLICE
CONCRETE FOUNDATION/BASE RAIL
ANCHOR DETAIL
REINFORCING STEEL (REBAR) REQUIREMENTS:
—MINIMUM GRADE 40 STEEL
—REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED:
—THE REBAR IS BENT COLD
—THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6—BAR DIAMETERS: AND
—REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED
TO BE BENT TO ALIGN WITH A VERTICAL CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1"
HORIZONTALLY TO 6" VERTICALLY.
—COVER:
—2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND
1}" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF 4" FOR FINE GROUT,
AND }" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL. REBAR USED IN MASONRY WALLS SHALL HAVE A
MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR
WEATHER, AND 14" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER.
GALVANIZATION-
-METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE
GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED
DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED.
P.-90
CODE VERSION
FBE 2017 6N E n,
_I
O
MANUFACTURER
CARPoRTS ANYWHERE
BUILDING TYPE
krWT, 6TRUCTURE
O
_.
CONSRiUCDONIYPL _ _
II_0_ _
RISK CATEGORY
RNE PROTECNON
NONE
FIRE SUPPRESSION SYSTEM
NONE
OCCUPANCY
m uGB
BASIC WIND SPEED
Va 170.p
EXPOSURE
C
ENCLOSURE
FNCIMW
INIFANAL PRESSURE COEFDCIEW
a/- 0.10
IMPORTANCE FACTOR
1-15
ROOF DEAD LOAD
10PSF
ROOF LIVE LOAD
20PSF ON 3001e POINT IMD
FLOOR DEAD LOW
10PSr
FLOOR DVE LOAD
WPEr
•R• RATING OF WALLS, FLOOR. ROOF
N/A
4000LES PER BUILDING
1
HURRICANE PROTECDON USAGE
NO
HURRICANE SHELTER USAGE
INO
SOUARE FOOTAGE
I iZDO S0. FT.
O
1�qq'od(-o r3 ROLL ;UP
o
REVIEWED FOR DOOR
CODE COMPLIANCE
ST. LUCIE COUNTY !
B..n B,
MTB
Date:
i
/'� 1
BOCC
4/11/19
Lo<O500
5001 Silver Oak Dr., Ft. Pierce, 34982
Da.l
401 X 30'W X 14'H
CMFRei NOTES
1. THIS BOLDING IS EKEMPT FROM THE FEE ENERGY
CONSERYAMM CODE PER SECWN CIGIA4 .
2 ALL STEEL MBING 51441 BE 50 NEI STFEL.
3. PWIVENG. ELECTWCN.. INGRESS/EGRESS PROPERTY
SET -BALKS. AND/OR OTHER LOW. CODE REOUWEMENTS ARE
THE RESPONSIBNM OF THE OWNER.
4. ROOF AND WALL SHEATHING SECURED WRH /12-14x1"
1
SELF-DRWNG SCREWS WITH SEAL WASHERS C 6' O.C. MAY.
FLEW FRAWNG CONNECDONS SECURED WITH /12-143/4'
SELF-DRUJ uREWs
S. ALL SHOP WH CONNECNONS ME TO BE WETDEO. NO
MWING ONSITE. ALL WELDING DONE N SHOP.
7. CONCRETE WANSONS ANCHORS ME TO BE MINIMUM
O
% 2'x3'. 2.600LB 11NSLE STRENGTH.
& 12 OR flGk FPAMING IS 2.6�r3.6" NEE SIEFl. LUPREB
L
ME 2.25'#]5' T18E STEEL
O
o
�
O
SCANNED
Dd
BY i
St. Lucie County i
12"x12" REINFORCED FOOTER
— I>
----------------------------- -- p+ oR
w
4/ 13/ 19
>
Matthew T. BOldw7D P.E.
3•-0„.T
o e e 20
11
6/
I7V
J
Sheet: CA-1 OF 4
e
TALL -UP
OOOH
12 U POS
(GGH SIDE OF
DOLL -UP pall
FRONT END WALL
m wNG11
WOR
3'-0'
LEFT SIDE WALL
ROLL -TIP
WJR
12 Ck POST
(ETCH 90E OF All
ROLL -UP DOORS)
REAR END WALL
RIGHT SIDE WALL
WOE VERSION
1,G 3011 .0 E61bn. AUE-T-10
MANUFACNRER
BUR-DING TYPE
CONSTRUCOON� E_RISK
CATEGORYRK
"MNE
PROTECNON
FlRE SUPPRESSION SYSTEM
ENCLOSURE
LNCLOsm
INTEMM PRESSURE COEFFICIENT
+/- 0.18
IMPORTANCE FACTOR
1.16
ROOF DEAD LOAD
10PSF
ROOF TINE LOAD
20PSF OR 3.1mW IA+a
FLOOR DUD LOAD
10P
FLOOR LIVE LOAD
SOPS,
W RAPNG OF wAL1S, ELGO. ROOF
N/A
MODULES PER BUILDING
1
1200 S0. R.
8001 Silver Oak Dr., Ft. Pierce, 34982
otlel
40�L % 30*W X 14'H
1. THIS BUILDING, Is EXEMPT EAOM THE FLOC ENERGY
CONSER✓ATION CODE PER SECTION C101A3.
2. NL STEEL. MENG SI BE 50 NS SIFE-
3.PLUMBING, EIECTmM INGRESS/EGRESS PROPERTY
nFT_Re A ANO/OR OTHER 1➢PN. WOE RWUIREMENTS ARE
3E T(I BE SHOP. wELDE0. NO 1
IE TO ^11I
IE TO BE MINIMUM
1.
NBE STEEL NIPPLES
V/
L1J
V
Z_
Q DIY/Y�
w 4/13/19
86 Matthew T. Baldwin P.E.
W III��. 11sa���cTgte R, dnDeLcn 4Fi0ina
Fn Sh9 ll-. -COPV
z
11K�
LEFT SIDE WALL
FRONT END WALL
SPONGING
DOOR
REAR END WALL
RIGHT SIDE WALL
CODE VERSION FBG iG1T su c.n;n. AscE-T-+a
MANUFACNRER CARPoWS AMWHERE
e,,,, n,un rwc IIRIrD' SfRDCDWE
RISK CATEGORY
I
FIRE PROTECDON
NONE
FIRE SUPPRESSION WErrEM
NONE
OCCUPANCY
STOWWE
BASIC WIND SPEED
EXPOSURE
C
ENCLOSURE
ENC,CSED
INTERNAL PRESSURE COEFFICIENT
./- 0.18
IMPORTANCE FACTOR
1.15
ROOF DEAD LOAD
+GPSF
ROOF m LOAD
2GPSF OR 3Com FGIRF Lab
FLOOR DEAD LOAD
+GPSF
ROOK LIVE LOAD
GGPSF
' RATING OF WALLS, ROOF, ROOF
N/A
MODULES PER BUILDING
1
HURRICANE PROTECf10N USAGE
NO
HURRCANE SHELTER USAGE
NO
SQUARE FOOTAGE
1200 S0. FI.
MTB
4/11/19
500 500
1 Silver Oak Or., Ft. Pierce, 34982
m:
40'L % 30'W X 14'H
,ns LDiNc Is IXEMPT FROM THE NBC MOW
9NSERVARON CODE PER SECDON C101A2.
LL STEEL. MENG smW BE 30 ON Si
.UMBING, EIEGTIGCAL. INGRESS/EGRESS, PROPERTY
J-GXM AND/OR OTHIA LOW. CODE REANREMFNIS ARE
iE RESPoNSIBRRY OF WE OWINER
DOF AND Wu SHEATWNG SECURED WOH /13-14It
Eli-DRIw G SCREWS WIn SEAL WASHERS o B' oc MA1L
Q-D FIRMING WN ECNONS SECURED WITH /13-1443/r
Eli-DWW G SCREWS.
LL SHOP FRAMING CONNECTIONS APE TO BE WELDED. NO
MING ONSIIE All WMING GONE IN SHOP.
ONCREIE IXPANSCNS ANCHORS ARE TO BE MINIMUM
/313_, 2,5WLE TENSILE STRO M.
1tG 2 OR A FRAMDG Is 2 bvQS* TUBE STEEL NIPPLES
Cn
w ,
W
i
w
4/13/19
MGttheW T. Baldwin P.E.
Florida Lice Be
OCRW
n W6
0_
U)
I Sheet:
A-3 OF4
MINIMUM 6" TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
(4)812-14x)' SELF-DRIWNG SCREWS
4
4' /NIPPLE TO
Rscr RAIL
POST TO BASE RAIL
CONNECTION
MINIMUM 6' TS NIPPLE NIPPLE
SECURED TO WALL POST W"
(41112-14,4" SELF —DRILLING SCREWS
Vx2'RY 16 GA. ANGLE CUP SECURED
" (4) /12-1414" SELF —DRILLING
SCREWS
END POST TO BASE RAIL
CONNECTION
A. ANGLE CLIP
SCE
NON—STRUCTURAL NON—STRUCTURAL HEADER OR
WINDOW RAIL TO POST DETAIL
INTERIOR
/12-141a' SELF—DRIWNG
SCREWS ® 10" O.C. MAX.. 3'
MAX. FROM CORNERS
HORIZONTALLY/ 4" MAX. FROM
CORNERS VERTICALLY
EXTERIOR
DOOR FRAME TO POST
CONNECTION
2'x2"x2' 16 GA ANGLE CUP
SECURED WITH (4) /12-144'
16 GA. ANGLE CUP SECURED SELF—DRIWNG SCREWS
SOY—DRILLING-14,aSOY—DRILLING
OR DOUBLE TS HEADER
INTERMEDIATE POST TO
HEADER/BASE RAIL/OR HEADER CONNECTION
WINDOW RAIL DETAIL DETAIL OPTION 1
2"x2"x2" 16 GA ANGLE CLIP SECURED
WITH (4) #12-14X3" SELF —DRILLING
SCREWS
VARIES
-1-ItSTD. MAX. SPACING
3" MIN.
STD. MAX. SPACING
,E-VARIES �i
Q
4 I' SIDE WALL ROLL —UP
DOOR HEADER DETAIL
INSTALL PER MANUFACTURERS INSTRUCTIONS
SELF—DRIWNG
a O.C. MAX&
FROM CORNERS
ROLL —UP DOOR TO
POST CONNECTION
DESIGN PRESSURES
— 170 Mph
ROOF
+24.6/-54.3
WALLS
+28.9/-26.0
DOORS
+28.9/-26.0
WINDOWS
+28.9/-26.0
1
2
3
4
5
ZONE
+12.4
—27.7
+15.5
—42.3
+24.6
—54.3
+28.9
—26.0
+27.8
—24.8
26 GAUGE ROOF SHEATHING SECURED
WITH (1)/12-14X}' SELF—DRIWNG
SCREWS 0 6' D.C. (9" O.C. MAX.)
1' 16 GAUGE FURRING CHANNEL "'
O.C. MAIL SECURED WITH (2)812-14x1"
SELF—DRIWNG SCREWS TO EACH RAFTER
ROOF PANEL CONNECTION
VERTICAL SHEATHING OPTION
16 CA U—CHANNEL BRACE.
MIN. 24' UP TO ]' POST,
MIN. 48' OVER ]' POST. MIN.
45' TO MAX. 6O FROM
HORR. (EXCLUDE END —WALLS
MINIMUM 6" TS NIPPLE NIPPLE
SECURED TO WALL POST WITH
(4)J12-144" SELF—DRIWNG SCREWS
MINIMUM 6" TS NIPPLE. NIPPLE
TO WALL POST WITH
144" SELF —DRILLING SCREWS
OR DOUBLE TS HEADER
HEADER CONNECTION DETAIL
OPTION 2
BOX EAVE RAFTER TO TRUSSED RAFTER
POST CONNECTION DETAIL CONNECTION DETAIL
MINIMUM 6' TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
(4)812-14x4" SELF —DRILLING SCREWS
POST TO TRUSS
APPROVED PRODUCTS
APPROVAL NO.
ROOF {SHEATHING
Carports Anywhere
FL27402.1
Hampton Rib Roof Panel
WALL SHEATHING
Carports Anywhere
FL27403.1
Hampton Rib Wall Panel
SWINGING DOOR
ELIXER DOOR AND METAL COMPANY
FL17996.5
407 STEEL DOOR
ROLL —UP DOOR
JANUS INTERNATIONAL CORPORATION
FL12765.4
SERIES 3100
CMPOM MMME
CODE INFORMATION
SION
ITC: 201] 5N EdAI-. ASCE-]-1
URER
W+PORis ITIYIINFAE
TYPE
UR SaUmn
RON TYPE
11-R
_ _ _
NCARGORY
RISKGORYECRON
NONEPRESSION
SYSTEM
NONECY
SPORAGE
BASIC WIND SPEED
V�-1TOmp,
EXPOSURE
O
ENCLOSURE
ENCIMM
INTERNAL PRESSURE COEFFICIENT
IMPORTANCE FACTOR
1.15
ROOF DEAD LOAD
10PSF
ROOF UW LOAD
201PSF OR 3001A FONT LOAD
FLOOR DEAD L AAD
'.z
FLOOR UYE LOAD
e5P6F
'R' RATING OF WALLS, FLOOR, ROOF
N/A
MODULES PER BUILDING
I
HURRICANE PROTECRON USAGE
NO
HURRICANE SHELTER USAGE
NO
SQUARE FOOTAGE
72. 5I
REVISIONS
REV
DESCRIPTON
DATE
BY
(n
J
Q
Q
Drcnn BY: MTB
O.W.
4/11/19
L Dom
5001 S1IVer Oak Dr., Ft. e, 34982
oEel
40'L X 30'W X
t' E%.L N016
1. THIS BUII ATO 5 IXFMPF FROM TENERGY
CL wEEL TU CODE PER SECTION C.
2, pll STER E.ECTRfflNG IN RE 50 N51
OPERTY
3. PLUMHING, E1MD/ORL. OTHER
SET -RASPS. MD/OR OTHER LOCAL CDUWEMENIs ARE
THE AND *,IBNIT OF THE OWNER
4 ROOF AND WALL CREWS ,MGNG SECURED 12 A. 0.c
SELD FRAM14G SCREWS WNH SEAL ECU WAO A. O.3 VA%.5. RELD FRAMING CORNEGRON$ SECURE/@-14x3/C
sLLSHOP11NG scGehs.
6. ALL SHOP FPAA6NG D. WENG ARE IN BE WEDGED. NO
WELOWG OWA AL. WELDING DONE IN SHOP.
]. CONCRELE EXPNISONS ANCHORS IRE 1(I BE MINIMUM
1/2OR j FRA TENSIIE SIRENGTN.
8. 12 OR IArd FATUBE IS 25'#.5' TUBE SRII. NIPPLES
APE 225'�315' TUBE STEEL
4/13/19
Matthew T. BGIdWin P.E.
FI n # 608
0
Sheet: CA-4 OF 4
FILE COPY
0
FILE COPY
mm
I+
2.5• PLAN VIEW BUILDING FRAMING
3' RECESS
I- DOOR WIDTH�i
ELEVATION VIEW
BUILDING FRAMING
RECESS
.75'JDOOR WID
OPTIONAL ROLL —UP DOOR
-CONCRETE SPLASH —GUARD RECESS
2,500 PSI 4" CONCRETE SLAB WITH W.W.F. (OR FIBER
NOTES: MESH) AND 12"02" REINFORCED FOOTER PERIMETER
SUB —GRADE SOILS:
—TO BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDANT PER SECTION R318 AND 1816 OF THE 2017 FLORIDA
BUILDING CODE, 6TH EDITION
CONCRETE:
—MINIMUM 2,500 PSI COMPRESSIVE STRENGTH AT 28 DAYS
ALL OPEN AREAS OF CONCRETE OUTSIDE OF THE PROPOSED STRUCTURE SHALL BE DESIGNED TO SLOPE AWAY FROM THE
STRUCTURE
f�.
+ 4Y v1�
s,
}'xSW EXPANSION ANCHOR WITHIN 6' OF
EACH POST/TRUSS ALONG SIDES AND
EVERY OTHER END —WALL POST
2" MIN. _ E RAIL
GRADE
2,5( CRETE
SLAB WITH W.W.F. OR
FIBER MESH
(2) TI5 REBAR TM O.C.
MINIMUM SOIL BEARING CONTINUOUS WITH MINIMUM
CAPACITY 2.000 PSF OYP.) 12" OVERLAP SPLICE
CONCRETE FOUNDATION/BASE RAIL
ANCHOR DETAIL
REINFORCING STEEL (REBAR) REQUIREMENTS,
-MINIMUM GRADE 40 STEEL
-REBAR MAY BE BENT IN SHOP OR FIELD PROVIDED:
-THE REBAR IS BENT COLD
-THE DIAMETER OF THE BEND MEASURED ON THE INSIDE DOES NOT EXCEED 6-BAR DIAMETERS: AND
-REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD BENT EXCEPT IN CASES WHERE DOWELS NEED
TO BE BENT TO ALIGN WITH A VERTICAL CELL. THESE REBAR MAY BE BENT NOT TO EXCEED TO SLOPE OF 1"
HORIZONTALLY TO 6" VERTICALLY.
-COVER:
-2" COVER MINIMUM WHERE THE CONCRETE IS CAST AGAINST AND PERMANENTLY IN CONTACT WITH SOIL OR WEATHER, AND
14" ELSEWHERE. REBAR EMBEDDED IN GROUTED CELLS SHALL HAVE A MINIMUM CLEAR DISTANCE OF J" FOR FINE GROUT,
AND k" FOR COARSE GROUT BETWEEN REBAR AND ANY FACE OF A CELL. REBAR USED IN MASONRY WALLS SHALL HAVE A
MASONRY COVER (INCLUDING GROUT) OF NOT LESS THAN 2" FOR MASONRY UNITS WITH FACE EXPOSED TO EARTH OR
WEATHER, AND 1}" FOR MASONRY UNITS NOT EXPOSED TO EARTH OR WEATHER.
GALVANIZATION:
-METAL ACCESSORIES FOR USE IN EXTERIOR WALL CONSTRUCTION AND NOT DIRECTLY EXPOSED TO WEATHER SHALL BE
GALVANIZED IN ACCORDANCE WITH ASTM A 153, CLASS B-2. METAL PLATE CONNECTORS, SCREWS, BOLTS, AND NAILS EXPOSED
DIRECTLY TO WEATHER SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED.
REVIEWED FOR
OfAPLIANCE
g�®LUCIIE COUNTY
®OCC
COUNTY
DIVISION
FOR
REVIEWED BY
MUST DE iSWCA
NO INSPECTION OR
eCounty
12"x12" REINFORCED FOOTER St. Luc
1
ROLL
_I
O
I
e I4�.7
O
0
CODE VERSION
MANUFACTURER
9UIlDMG TYPE
CONSTPUCTION TYPE
RSK CATEGORY
FIRE PROTECr1ON
FIRE SVPPRMON SYSTEM
DCCUPA cv
e C "No SPEID
EVOSURE
FNCIDSURE
M MAL PRESSURE Cosnna Nr
IMPORDMCE FACTOR
ROOF DM IDAD
ROOF 111'E lDAO
FLOOR DM LOAD
FLOOR 11YE LOAD
'R' RA1MG OF WALLS, FLOOR, ROOF
MODULE PER BUMING
HUMCANE PROTECnON USAGE
HURMCANE SHELTER USAGE
SaU ROOFAGE
REVISIO
REV
I DESCRIPLO
1
' R okw Ap0E0 m scam OLTNL
F.1
M17 . EENon.
0.10
W
MTB
4/11/19
Silver Oak Dr., Ft. Pierce, 34982
401 X 30'W X 14'H
INO Is E10'MPT FROM IRE FEC mN
NO
0 L61U R I6 F AWNG TUBE IIS ZB'a.6' MBE sR21. NPNES
We
ow -we
'9L
a A
S
w
8/26/19
Matthew T. BaltlWin P.E.
z
Florida License #64608
'
og
Sheet: CA-1 OF 4
12 GA
FRONT END WALL
S""G
DaoR
LEFT SIDE WALL
Wo -w
DOOR
10
12 G& Po
EAG 9DE OF
Rat-w DDa
REAR END WALL
RIGHT SIDE WALL
REVIEWED FOR
CODE COMPLIANCE
ST. LUCIE COUNTY
ROCC
ft F .
a1UCDON D E
CATEGORY
PROIEMON
sU itl SIGN sYSTEW
PANcY
WND SPEED
WRE
)SURE
NAL PRESSURE COEFFlpQR
RANCE FACTOR
am LQAO
M LOID
i DEAD OAD
I THE aA0
A1NG OF WALLS, FLOOR, ROOF
L FER DU[ICNG
[CANE PR01ECn01( USIGE
ICANE S nMt USAGE
RE FOOFAGE
REVISIO1
DESCRIPT01
'cFno%V AWED w FaDen MA
5001 Silver Oak Dr., Ft. Pierce, 34982
aaa
401 X 30'W X 14'H
1. R., G Is E41IPE FROW WE M ENER
�2. ALL51 wmNGG s�W w ECilED m010�I Al2
O. PWWMNQ ELEctmcm. NGRfw/EGR65, PROPERrc
gT-DICK. AND/OR ORRR EOCIL WOE REaUIREMEIM IAf
l.liN INp W�111 4ENMING TRE� WRR /12-141'
sEli-DRUING SMIE" *RR SIX WA90SS a e' QQ WAIL
S.FELD FRAIING COK$ W NE SEWRED WITH /12-I4.3/4'
sFlF- WNG SCREWS.
& ILL SHOP TRUING aNs ARE m eE *E . No
). W EIwANso�Ns�a10 s eREE m . Ww4uW
1/2t . 2,5 IENSRE 51REIICIN.
612 OR 1� FNNNG IS 26'A2.5' WK S NRPLFS
LJ
W
5-
CD
Z_
L
Q
0
w
8/26/19
MattheW T. BaldWln P.E.
W
Florida License #64608
0
U)
Sheet.
CA-2 OF 4
FRONT END WALL
LEFF SIDE WALL
Sam
DOOR
_-
(tr—. iAk"
REAR END WALL
RIGHT SIDE WALL
REVIEWED FOR
CODE COMPLIANCE
J E a LUCIE COUNTY
13OCC
I e 1 0 i >
M1F 6M
TYPE
A J"I 'JT�PI
FNCIMURE
a1a.•O8D
INTERNAL PNESSUW COEFFICIENT
+/- 0.1e
IMPORTANCE FACTOR
1.1e
ROOF DEAD LOAD
tuns
ROOF t LMD
=M OR aaom PartT Iwo
FLOOR DFAD LOAD
101�
FLOOR IN¢ LOAD
aoP3
'R' RAIING OF WALLS, FL00R, ROOF
WA
MODULES PER WIWING
I
W. R.
r —>t. lr.
MT6
4/11/19
Silver Oak Dr., Ft. Pierce, 34982
40-L X 30-W X 14-H
DaMPT FROM THE FBC MOM
TO W wE1DE0. No
IN eR ly
Ta eE�iR1IMuM
DE 51EEL NlrelFs
U
LLJ
o
-
w
8/26/19
Matthew T. Baldwin P.E.
LLJ
Florida License #64608
0
(n
Sheet:
CA-3 OF 4
INTERIOR
MINIMUM 6' TS NIPPLE NIPPLE
SECURED TO WALL POST WITH
(4)012-1414' SELF-DRIWNG SCREWS
POST TO BASE RAIL
CONNECTION
MINIMUM 6' TS NIPPLE NIPPLE
SECURED TO WALL POST WITH
(4)112-144' SELF-DRIWNG SCREWS
2'x2'x2' 16 FA ANGLE CUP SECURED
WTIH (4) P12-144' SELF-DRIWNG
SCREWS
END POST TO BASE RAIL
CONNECTION
A ANGLE CUP
SCREWS-14xi?"
NON—STRUCTURAL HEADER OR
WINDOW RAIL TO POST DETAIL
EXTERIOR
SEIF-DRIWNG
10' O.C. MAX.. 3'
CORNERS
LY/ 4' MAX FROM
DOOR FRAME TO POST
CONNECTION
2'x2'x2' 16 CA, ANGLE CUP SECURED
WITH (4) 012-141j' SELF -DRILLING
SCREWS
mow
2'x3'x2' 16 GA ANGLE CUP
SECURED WITH (4) 112-144-
SE -DRIWNG SCREWS
OR DOUBLE TS HEADER
INTERMEDIATE POST TO
HEADER/BASE RAIL/OR HEADER CONNECTION
WINDOW RAIL DETAIL DETAIL OPTION 1
2"x2"x2" 16 GA ANGLE CUP SECURED
WITH (4) #12-14xj" SELF —DRILLING
SCREWS
VARIES
STD. MAX. SPACIN
3" MIN.
STD. MAX. SP CING
OVARIES�i
K
i' SIDE WALL ROLL —UP
DOOR HEADER DETAIL
INSTALL PER MANUFACTURERS INSIRUCILONS
114x1' SELF-DRIWNG
SCREWS O 6' O.C. MAX. @
6MAX FROM CORNERS
ROLL —UP DOOR TO
POST CONNECTION
DESIGN PRESSURES
— 170 Mph
ROOF
+24.6/-54.3
WALLS
+28.9/-26.0
DOORS
+28.9/-26.0
WINDOWS
+28.9/-26.0
1
2
3
4
5
ZONE
+12.4
—27.7
+15.5
—42.3
+24.6
—54.3
+28.9
—26.0
+27.8
—24.8
26 GAUGE ROOF SHEATHING SECURED
µITN (1)112-14,r SELF-DRIWNG
SCREWS O 6' O.C. (9' O.C. MAX.)
1' 16 GAUGE FURRING CHANNEL 48"
O.C. MAIL SECURED WITH (2)P13-14x1'
SELF-DRIWNG SCREWS TO EACH RAFTER.
ROOF PANEL CONNECTION
VERTICAL SHEATHING OPTION
16 GA. U-CHANNEL BRACE.
MIN, 2C UP TO T POST.
MIN. 4B' OVER T POST. MIN.
45 TO MAX. 6P FROM
NORM (E)(CLUDE ENO -WALLS;
MINIMUM 6' TS NIPPLE. NIPPLE
SECURED TO WALL POST WITH
(4)112-144" SELF—DRIWNG SCREWS
BOX EAVE RAFTER TO
POST CONNECTION DETAIL
IMu : Tie. NIPPLE
T ALL RI W
(4)P1z-u>a' SELF-DRIwNG scRT:Ws
OR DOUBLE TS HEADER
f91ILDING TYPE
CONSTRUCTION TIT
HEADER CONNECTION DETAIL RISx CATEGORY
OPTION 2 1
FlRE PROTELTON
ME SUPPRESSION
TRUSSED RAFTER
CONNECTION DETAIL'
1
MINIMUM 6' TS NIPPLE NIPPLE
SECURED TO WALL POST WITH
(4)P12-14,4' SELF-DRIWNG SCREWS
IMPORTANCE FACTOR
ROOF DEAD LOAD
ROOF LIVE LOAD
FLOOR DEAD LOAD
FLOOR UVE LOAD
'R• RATING OF WALLS. FLOOR, ROOF
MODULES PER BUILDING
HURRICANE SHELTER USAGE
SOUARE F00TAGE
RNSIOl
POST TO TRUSS R 1 DESCRIPTOI
CONNECTION I
IEWEp FOR
COMPLIANCE
)CIE COuNT�
BOCC
APPROVED PRODUCTS
APPROVAL NO.
ROOF SHEATHING
Carports Anywhere
FL27402.1
Hampton Rib Roof Panel
WALL SHEATHING
Carports Anywhere
FL27403.1
Hampton Rib Wall Panel
SWINGING DOOR
ELIXER DOOR AND METAL COMPANY
FL17996.5
407 STEEL DOOR
ROLL —UP DOOR
JANUS INTERNATIONAL CORPORATION
FL12765.4
SERIES 3100
=12 M
1,200
1 5001 Silver Oak Dr., Ft. Pierce, 34982 II
EEi40'L X 3D'W X 14'H
. THIS BNIDI IG IS EXWPT FROM THE I'M ETIERar
ARE
m BE WELOEo. No
IN A m GNwum
BE STD.. NIPRES
VA
8/26/19
J Matthew T. BaldWin P.E.
Q Florida License #64608
w
o sheet: CA-4 OF 4