Loading...
HomeMy WebLinkAboutEVALUATION REPORTFIA 27403.1 Force Engineering 8c Testing Inc. 19530 R oxble d Drive H.ble.TX 77338 Product Evaluation Report CARPORTS ANYWHERE Hampton Rib Wall Panel over open framing Florida Product Approval # 21463.1 Florida Building Code 2017 Per Rule 61G20-3 Method: 2-11 Category: Structural Components Subcategory: Structural Wall Compliance Method:61G20-3.005(2)(b) NON HVHZ Product Manufacturer: Carport Anywhere 10858 S.E. County Road 221 Starke, Florida 32091' Eneineer Evaluator: Terrence E. Wolfe„P.E. # 44923 Florida Evaluation ANE ID: 1920 Validator• Gary Hartman, P.E. 1173227 Contents: Evaluation Report Pages 1-4 4q- k CENSE ///777 �No. 4A� STATE OF ;off AL0g19P AL � ONrIffIM`l Ju.oe.18, SCANNED BY St. Lucie County Force F meeting 8c Testing Iac 195301tamblea ood Drim Hmnblc rX 77338 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1709.2. Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Wall Panel, 36" Wide, through fastened stmctumlwall panel. Structural Application. Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50 29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80 Conforming to Florida Building Code 2017 Section 1405.2; Panel Dimension(s): Thickness: 26 Ga.: 0.0185" min. order thickness 29 Ga.: 0.0142" min. order thickness Width: 36" maximum coverage Rib Height: Y." major rib at 9" O.C. Panel Rollformer. MRS Metal Roliforming Systems Panel Fastener: #12-14 x'/." HWH SD#3 with 14mm neoprene bonded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017. Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel gauge. Framing must be designed in accordance w/ Florida Building Code 2017. Allowable Design Pressures: Table "A" 26 Ga. Hampton Rlb Wall Panel Maximum Design Pressure: -57.3 psf -72.9 psf -67.7 psf +46.9 psf +54.7 psf Panel Fastener Panem: 2-1-2-1 2-1-2-1 2-1-2-1 2-1-2-1 Panel Span: V-ol O.G 4'-V O.C. 4-W O.C. 5'-o"0.r— Substrate: Min. 14 Ga. Steel Framing Min. 14 Ga. Steel Framing MIn.14Ga. Steel Framing Min. 18 Ga. Steel Framing Min. 18 Ga. Steel Framing 'Design Pressure includes a Safety Factor =2.0. `3tpttltlrirr'"" ,`% r"I No. 449� �•o• STATE OF ;r 0R19A ss.artea "i FS •. ti�� YYIA A lro IIf110,f0 FL# 27403.1 Jlul�18, 2.018 Force Enginecring & Testing Inc. 19530 Rumblmood Drive Humblc,TX77338 Table "a" 29 Ga. Hampton Rib Wall Panel Maximum Design Pressure: -57.3 psf -1509 psi +39.0 pst +143.1'psf Fastener Pattern: 6'-3 Fastener Sp acing: 4'-0"O.C. T-0"O.C. 4'-0"O.C. 2--V O.C. -Design Pressure Includes a Safety Factor= 2.0. Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1709.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 63G20-3. Performance Standards: The product described herein has demonstrated compliance with: • ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference Reference Data: ,1. ASTM E 1592-05 (2012) Test Force Engineering & Testing; Inc. (FBC Organization #TST-5328) Report No. 667-006OT-18A-E, 667-0061T--ISA-D 2. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization # ANE ID: 1920) Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for - manufacturing under a quality assurance program audited by an approved quality assurance entity. Installation: Install per manufacturers recommended details. Insulation: Manufacturers approved product (Optional) Panel Fire Classification: Fire classification is not part of this acceptance. FL# 27403.1 %%43,,\t C E I E t /rt22. �, p�Vt C E PJS A 7F� '•' STATE OF mpg y AiOR11) ORAL cns S Jtcoz,18, 2018 Force Engineering &Testing inc. 195301tnmble .d Dme Humble,TX 77338 Shear Diaphragm: Shear diaphragm values are outside the scope of this report Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 forwall cladding wind loads. These component wind loads for wall cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pulloutand pullover.'Support framing must be in compliancewith Florida Building Code 2017 thapter22 for steel, and Chapter 16 for structural loading. E, q CE NSF V �No. 449 STATE OF ; AiORIbA.�+4 sr o�rnsf -fy; • , • Vti �� .rm ,,r ti ONntltPNt°� FL# 27403.1 Ju+z18, 2018 26 GA. HAMPTON RIB FASTENER PATTERN 2-1-2-1 14 v 3/4' HUH S03 W/ 14MM BONDEDNEOPRENE WASHER 29 GA. HAMPTON RIB FASTENER PATTERN V-3"-6"-3"-6"-3"-6" 6' — 3. 6. —,— 3' , — 6' _ . - 3.- , - 6' 3. 4 x 3/4' HWH S03 W/ 14MM ECHOED NEOPRENE WASHER Sao dt FlOddo O.OA diffm No. 44923� k- S STAT 0' ?�v�: L• 1MN182818 rForceEngineering & Testing Inc. 19530 Fi=bI..ad Drive H=W;rX 77338 Product Evaluation Report CARPORTS ANYWHERE Hampton Rib Roof Panel over open framing Florida Product Approval 1# 27402.1 Florida Building Cade 2017 Per Rule 61G20-3 Method: I—D Category: Structural Components Subcategory: Roof Deck Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: CarportAnywhere 10858 S.E. County Road 2Z1 Starke, Florida 3ZO91 Engineer Evaluator: Terrence E. Wolfe, P.E. # 449Z3 .Florida Evaluation ANE ID: 1920 Validator' Gary Hartman, P.E. #73227 Contents' Evaluation Report Pages 1-4 \,\ptunrrgtr' N,C E_ CENse�,P�: STALE OF w-1'zox19A, 4 sa orw 01Fs; ., SGANNEC BY St. Lucie County FL# 27402.1 Ju.nz 18, 2018 V Force Engineering & Testing Inc. 19530 RambIMood Drive Humble=77333 Compliance Statement: The product as described In this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2, 1504.7. Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Roof Panel, 36" Wide, through fastened structural roof panel. Structural Application. PanelMaterial/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50 29 Ga. Steel, ASTM A792 4r ASTM A653 G90 Grade 80 Conforming to Florida Building Code 2017 Section 1507.43. Optional paint finish. Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 26 Ga.: 0.0185" min. order thickness 29 Ga.: 0.0142" min. order thickness Width: 36" maximum coverage Rib Height %" major rib at 9" O.C. Panel Rollformer. MRS Metal Rollforming Systems Panel Fastener: #12-14 x Y" HWH SOp3 with 14mm neoprene banded washing or approved equal. Corrosion Resistance: Per Florida Building Code 2017, Section 1507.4A. Substrate Description: Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel framing, 4r Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B forsteel gauge. Framing must be designed in accordance w/ Florida Building Cade 2017. Allowable Design Pressures: Table "A" 26 Ga. Hampton Rib Roof Panel Maximum Deslgn Pressure: -57.3 psf -72.9 psf -67.7 psf ♦46.9 psi .54.7 psf Panel Fastener Panem: 2-1-2-1 2-1-2-1 2-1-2-1 2.1-2-1 2-1-2-1 Panel Span: 5b" O.C. 4'-W O.C. 4'-G" O.C. S'-0" O.C. 4'-W O.C. substrate: Min.14Ga. Steel Framing Min. 14 Ga. Steel Framing Min. 14 Ga. steel Framing Min. 18 Go. I Steel Framing Min. 18 Ga. I SteelFraming Ue51gn rressuM Includes a safety Factor -2.0. FL# 27402.1 ```'Htc E �e t t e %. P�VI CENSF tb.4A� STATE OF ; m W, JDtGti Ox19P`; N sm o�rbm. i,�E•s .. .arm , rtt``t`, JV-ft'.18a 2018 rFlorcengineering & Testing Inc. 19530 Rsmblcvd Drive HurribkaX 77338 Table "B" 29 Ga. Hamotun Rib Roof Panel Maximum Design Pressure: -57.3 psf -2509 psf +39.0 psf +143.1 psf Fastener Pattern: 6'-3"-6'-3"-6'-3"-6' 6'-3"-6--3"-6"-3"-6' 6'-3W-3-6--3'-6' 6'-3'-6'-3'-6'-3'-6' Fastener5pacing: 4'-0' O.C. 2'-W O.C. 4'-0" O.C. 2'-0' O.C. 'Design Pressure includes a Safety Factor= 2.0. Code Compllance: The product described herein has demonstrated compliance with The Florida Building Code 2017, Section 1504.3.2, 1504.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61GL0-3. Performance Standards: The product described. herein has demonstrated compliance with: • ASTM E 1592-05 (2012) Test method for structural performance of sheet metal roof and siding systems by uniform static air pressure difference • FM 4471-92- Foot Traffic Resistance Test Reference Data: 1. ASTM E 1592-05 (2012) Test Force Engineering &Testing, Inc. [FBC Organization #TST-5328) Report No. 657-0060T-1BA-E, 667-0061T--1HA-D 2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test Force Engineering &Testing, Inc. (FBC Organization # TST-5328) Report No. 657-0060T-18F, 667-0061f-18E 3. Certificate of Independence By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc. (FBC Organization It ANE ID: 1920) Test Standard Equivalency: The FM 4471-10, Foot Traffic Resistance test standard is equivalent to FM 4471-92. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. c E N S STATE OF ; oc v, OR19p`..�+4'� isr°m ,7�/��Olfrlfliw•�t ��. FL# 27402.1 Jua.,19, 201.8 Force En ' e�nngTestin Inc. 19530 1t,a,bt�oaa n.t,� Humbl,TX 77338 Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. Forslopes less than 3:12, lap sealant must be used In the panel side laps. Installation: Install per manufacturer's recommended details. Insulation: Manufacturer's approved product (Optional) Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report Design Procedure: Based on the dimensions of the structure, appropriate wind loads are determined using Chapter 16 of the Florida Building Cade 2017 for roof cladding wind loads. These component wind loads for roof cladding are compared to the allowable pressure listed above. The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover. Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel, and Chapter 16 for structural loading. FL# 27402.1 CtE rE rrrr2'. E.•-" %4k..Al STATEOF ;p 01t1 ID P �: maezree �i �'•. 4♦ rrm i�i � OVAL• E.`�� Jbwtz 18, 2018 26 GA. HAMPTON RIR FASTENER PATTERN 2-1-2-1 Q12-14 z 3/4' HWH SD3 W/ 14MM BONDED NEOPRENE VIASHER 29 GA. HAMPTON RIB FASTENER PATTERN 6"-3"-6"-3 6"-3"-6" 912-14 x 3/4' HWH S03 %V/ 14MM BONDED NEOPRENE WASHER amcifloltda FDA B2am No. 449_3 Jam- = 9 •. STATE OF DINI ;90182018 t on E�P V pop . Y � i�ti eoo �axm m 'e b a REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY SOCC FILE COPY