HomeMy WebLinkAboutPOOL ENCLOSURE PAPERWORKGENERALNOTES 1. DESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS: 1. THE 2017 FLORIDA BUILDING CODE, 6TH EDITION SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CHAPTER 23 WOOD. 2. ASCE 7-10. & SE17 3. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 4. ACI318 CONCRETE REFRENCE MANUAL. 5. PCI PRECAST & PRESTRESSED CONCRETE. 6. AA ASM 35 & AA ADM 1 WIND LOADS: 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 150 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: C 3. SCREENED ROOF ENCLOSURE FBC 2017 CH. 20 TABLE 2002.4 CONCRETE & FOUNDATION DESIGN: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: A. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: 1. PORTLAND CEMENT TYPE 1 -ASTM C 150 11. AGGREGATES - LARGE AGGREGATE 3/4" MAX. - ASTM C 33 III. AIR ENTRAINING +/- 1 %- ASTM C 260 IV. WATER REDUCING AGENT - ASTM C 494 V. CLEAN POTABLE WATER VI. OTHER ADMIXTURES NOT PERMITTED B. METAL ACCESSORIES SHALL CONFORM TO: I. REINFORCING BARS-ASTM A615, GRADE 60 II. WELDED WIRE FABRIC -ASTM Al85 C. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. D. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. E. MOIST CURE OR POLYETHYLENE CURING PERMITTED. F. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. G. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. FOOTING SIZE: EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB (3000 PSI) IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. 3. WHEN APPLICABLE FOR ATTACHING NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS. 4. WHEN INSTALLING 4" CONCRETE SLAB -ADD ADJACENT TO EXISTING-DOWELL INTO EXISTING CONCRETE 48" O/C W/8" #5 REBARS- DRILL 3/4" HOLE 4" EMBEDMENT- EPDXY Wl NON -SHRINKING "SIMPSON EPDXY TIE" (OR EQUAL). 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHER WISE NOTED. ;;. UMINUM SPECIFICATIONS: 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE SPECIFIED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH #12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. FASTNER SPECIFICATIONS: 1. FASTNERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG.) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, AND FASTENERS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1/4"X3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1 "X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1/4"X2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14X2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10X1-1/2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE VX2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS: 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2. ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. MISCELLANEOUS: RECEIVED APR 3 0 2019 ST. Lucie County, Permitting 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND INSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK W/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE SMB UNLESS OTHERWISE INDICATED. RESPONSIBILITIES: 1. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. LEGEND: (ALL MAY NOT APPL SCR = SCREEN KP = KICK PLATE PW = PICTURE WINDOW X= HORIZ. SLIDING WINDOW O = HORIZ. STATIONARY WINDOW DH = DOUBLE HUNG WINDOW SH= SINGLE HUNG WINDOW SIP = SOLID INSULATED PANEL CT = CABLE TIE SG = SUPER GUTTER CS = CLEAR SPAN KB = KNEE BRACE ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2"x2"x0.044" 2 x 3: 2"x3"x0.044" 2 x 4: 2"x4"4.044" 2 x 5: 2"x5"x0.050" OPEN BACK SECTIONS 1 x 2: 1 "x2"x0.044" 1 x 3: 1 "x3"x0.044" SNAP SECTIONS 2 x 2 SNAP: 2"x2"x0.050" 2 x 3 SNAP: 2"x3"x0.050" 2 x 4 SNAP: 2"x4"4.045" SELF MATING (SMB) 2 x 4 SMB: 2"x4"x0.044"x0.100" 2 x 5 SMB: 2"x5"x0.050"x0.100" 2 x 6 SMB: 2"x6"x0.050"x0.120" 2 x 7 SMB: 2"x7"x0.057"x0.120" 2 x 8 SMB: 2"x8"x0.072"x0.124" 2 x 9 SMB: 2"x9"x0.082"x0.124" 2 x 10 SMB: 2"xl0"x0.092"x0.398" NOTE: AS INDICATED ABOVE ALL MEMBER PROFILES ARE INDICATED :IN INCHES. Tg D4- 6-711 Fj44 BY St. Lucie County N O x ui a: a � o NN pip a „y � o � ui m F � o WALL HEIGHT PER PIA MT§ 00 O I I 1\\ - m I I 1 \ I I I \ i i I TRANSOM @ GUTTER 0 N X W X N O O X 1X3 G) --------�--------------------------- w 4X4X.125 y mI O i v I = I 1 I 2X7SMB -- 20'-0" I I I I O N x I I N IX 1 2X75MB--------- -- X o m N N N O v w w w A 6 _ \ j O 2X8SMB 101-011-, ,rci G) i O m m 7' 3X2 I 4X4X.125 � I �9' 8"� r30'-0" Z 0 1X3 O 00 N N X X X N Ln Ln F+ O r- X N N W N N m O Lo W O 60 m m N m 2X3 w -Oi z o m 0O 1X3 5 m I— -6'-8"-1�6'-8"--I- 6'-8"—i--101-0„�.�2'-0" ZO cn m a� Dm z� �� 902 cn m �0 XW c� n0 cZ r� �O m WO cn Z i =m O r Z� p - 1, N z CONTRACTOR: o m m o o z PIONEER SCREEN LLC FLORIDA ENGINEERING LLC N 4456 TAMIAMI TRAIL, UNIT B14 m PORT CHARLOTTE, FLORIDA 33980 N mmi IT PROJECT ADDRESS: (941 ) '391 _55980 KLIEBACK www.flengineeringlic.com 1487 NW SWEET BAY CIR raig E. Gunderson, P.E. #60102 jV m PALM CITY, FL PROJECT NO. 1910541 CA CERT.#30782 TE: 04/18/2019 I� X 1X2 X N tail � X W 2X2 N W FLASHING 1'12 FASTEN TO COL. (INTERNAL) W/(2) #10x1-1R" SMS, FASTEN TO EAVE RAILS ABOVE W/410Xt-1/2" SMS 24'O.C. AND 6°FROM END. \ TABLE D BEAM QTYEACHSIDESRE 2x3 4/12 2x4 8/10 2x5 8/10 2x8 10/10 2x7 12110 2x8 8/14 2 x 9 9114 2x10 9/14 MAINTAIN MIN, OF 5W SEPERATION FROM EDGE OF BEAM SMS O.C. DETAIL E - UPRIGHT TO BEAM CONNECTION SCALE: NTS NOTE: IF PAVERS ARE PRESENT, CONCRETE ANCHORS SHALL PENETRATEINTO NOTE: WHEN FASTENING TO WOOD USE 174" GALV. LAG SCREW IN LIEU OF CONC. ANCHORS AND j ENSURE PENETRATION MIN 2-1/4" INTO STRUCTURAL FRAMING BENEATH (TYP.) 5032 H-32 ANGLE 2-912 SMS INTO COLUMN 1/4" MASONRY ANCHOR EACH ANGLE - EACH SIDE COLS 3000 PSI CONC. SLAB/ FTG. 6x610x10 W WM OR FIBERMESH 'HORIZONTAL OR SLOPED BEAM PER PLAN NOTCHED TO RECEIVE COLUMN WITHIN SMS, (EACH SIDE) DTY PER TABLE D NOTCH PROFILE MAY VARY TO PERMIT CORRECT # SMS COLUMN PER PLANS TABLE "B" SECONDARY ANGLE SCHEDULE UPRIGHT QTY. TAPCON/ SCREW 2X3 0 2X4 1/ 2 2X$ 112 2X6 2/ 4 2X7 2/ 4 2X8 3/ 6 2X9 316 2X1G 4/8 SIDE VIEW SELF -MATING OR SNAP SECTION TYP. PER PLAN 1.1d- O.B. BASE PLATE-TYP 2-1/4" MIN. CONC. �— ANCHOREMBEDMENT (2)#10x2" INTO BEAM BEAM 2' MIN. WHEN GREATER THAN 2x4 UPRIGHT IS USED SEE TABLE ANGLE ,., +,,.,,, ANGLE SCHEDULE 1/4' MASONRY ANCHOR AT EACH ANGLE 2-#12 SMS V24v TAPCON bQ BASE XL (RED HEAD MFG. OR EQUAL) 2 A SLAB (BEYOND) ANCHOR V MAX EACH SIDE OF POST AND 24" O.C. MAX 3000 PSI CONG. SLAB/ FIG. ' / I 6x5-lox10 —/ FRONT VIEW W WM OR FIBERMESH DETAIL "B" -2"x4" OR LARGER SELF MATING UPRIGHT TO DECK DETAILS SCALE: N.T.S. (2) 010)3- SMS INTO SCREW BOSSES FOR EDGE MEMBEF EDGE MEMBER OR PURLIN PURLIN DETAIL "D" - ROOF BRACING CONNECTION DETAIL SCALE: MS � EDGE MEMBER n OR PURLIN 0.0625" 6063-T6 FLAT PLATE w/(8) #10YJ/4' SMS, MIN. 1/2- EDGE DISTANCE, PLATE MAY BE FASTENED INTERNALLY TO BRACE ALL MEMBERS PER PLAN 'MEMBERS VARY PER PLAN FASTEN TOP OF HEADER TO INTERSECTING MEMBER W(2) #10 SMS wli" PENETRATION INTO SCREW BOSS OF MEMBER - TYP. BOTH SIDES FASTEN HEADER wl(2) #10x3- INTO SCREW BOSS OF HEADER ALTERNATE HEADER CONNECTION WHEN Z-BAR IS USED- FASTEN Z-BAR TO COLIHEADER AT EACH CORNER AND 18'0/C ALTERNATE BASE PLATE CONNECTION ATTACH MEMBERTO BASE PLATE (INTERNAL) w/(2) #10)0 SMS ATTACH BASE PLATE TO MEMBER wl(2) #10x3' SMS INTO SCREW BOSS OF BASE PLATE � ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL w/(4) #10x75- INTO GIRT OR PURLIN S (2) #14x.75" INTO BEAM OR UPRIGHT 0,062 ANGLE CLIPS MAYBE USED > PURLIN 9 UPRIGHT, BEAM -SNAP, SELF MATING, OR HOLLOW II L MEMBER < DETAIL "C" - GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: NTS 1/4-TAPCON (RED HEAD MFG. OR EQUAL) WITHIN 6- OF COLUMN 824" O.C. MAX. 1-1/4' PENETRATION INTO UNDERLYING FOOTING DETAIL "F" - DOOR JAMB 8 HEDERA CONNECTION SCALE: NTS :'SMS INTO . BOSSES 3'x2- EDGE BEAM (2) #10x5- SMS PURLN INTO SCREW BOSSES CONNECTING EDGE BEAM TO PURLIN 2"13'X2'X1/8"ANGLE 1- i FASTENED TO COLUMN W/ (4) #12 X 3/4- EA LEG NOTCH COLUMN AS REQ'D. COLUMN PER PLAN DETAIL "G" - SLOPED PURLIN CONNECTION SCALE: NTS J 00 ro 0 m � # M z z O n/ U U W DO a) W LL Lo .c- C' z 0� WQ J ';t a) cy) � c Q Q V Lo ,t 0 O 1 ,O I..L d7 O Z' U W O a 1.1/2"x 1/16" PLATE (12)#12x1°SMS (TOP OR BOTTOM) @ 1°SPACING ` \\\1 0_ U U 39Q' EDGE BEAM J } J Q + Z m (2)#10x5'SMS p150-111 W W F- INTO SCREW BOSSES W CONNECTING EDGE BEAMTOPURLIN U U-I LL 1",6- FASTENED TO COLUMN (n w/(2)#10x1-1/2-SMS INTO N SCREW BOSSES FOR SMB OR SNAP COLUMN W It O Q (� W Z Q Z Wr-� V co d NOTCH COLUMN AS REQ'D. D.Y a- COLUMN PER PLAN Z F' L) a DESIGN DATE: 04/18/2019 EVISION I: DATE PAGE: ALTERNATEDETAIL"G"SLOPED] ®A PURLIN CONNECTION SCALE: NTS REVISION 2: DATE SCALE: NTS GIV FASTENED INTERNALLY AT EACH END / \ w/ tt10x1.5' EACH SCREW GROOVE. FASTEN TO BEAM w/ Wx.125 ANGLE (2) #12 EMS FOR BEAMS ABOVE 24 INSTALL INTO BEAM &(2)#10xl-1/2" THRU ANGLE INTO GUTTER BRACE AT MIDPOINT GUTTER WHERE NO GIRT IS PRESENT, ATTACH BETWEEN BEAMS & INCLUDE 2" ANGLE DIRECTLY TO GUTTER GUTTER BRACE AT EACH BEAM LOCATION 050" GUTTER STIFFNER ILL\\ FASTEN TO FASIAw(2) 2'Y2'x1/8'ANGLE I \ WOOD SCREW FASTEN TO GUTTER w(2) #125MS � Fl 0 BEAM (2) #14oQ" WOOD 11 (21#12 SMS SCREW I8'O.C. CLOSE BOTTOM OF BEAM WHEN TRIMMED 21Qxl/8'ANGLE EA SIDE OF BEAM w/(2) 412 SMS EACH LEG EACH S FOR BEAM OVER 2x5 .044 RECEIVING CHANNEL FASTEN TO STRUCTURAL GUTTER INTERNALLYwI(2)#12 SMS ALTERNATELY 2YdU/8' ANGLE BELOW GIRT, (2) #14 SMS INTO BEAM & (2) #12 SMS INTO STRUCTURAL GUTTER SIDE VIEW TOP VIEW DETAIL"H" SCALE:NTS FASTEN GUTTER TO FASCIAw/#14#' WOOD SCREW 18" O.C. (2) #12 SMS (2)#14x2- WOOD SCREW FASCIA(2"x6' MIN. EXISTING) STRUCTURAL GUTTER —ALTERNATELY SEE PAGE 5 m ° Frof of 0 F� of °� 0 0 ° F \ 0 o F NOTE F INSTALL FASTENERS ALONG PERIMETER OF GUSSET -BEAM JOINT 3/8" MIN, FROM EDGE. FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-1 FASTENER PATTERN MAY APPEAR DIFFERENT FROM ILLUSTRATION. MAINTAIN 1/2' SEPARATION BETWEEN FASTENERS. MAINTAIN 3/8- MIN, FASTENER SEPARATION FROM BEAM JOINT OR EDGE OF BEAM LAP FASTENERS MAY BE EVENLY SPACED AROUND EDGE OF GUSSET WITHIN 3/8' OF BEAM JOINT. FASTENERS MAY BE STAGGERED TO INSURE PROPER QUANTITY PER TABLE B-1 3/16"-5052-H32 GUSSET INTERNAL OR EXTERNAL (2X10SMB ILLUSTRATED) TABLE B-1 BEAM SQE OOL.TO BEAM Ott SMS/ SIDEOFCOL BEAMTO BEAM OTYSMS/ FACEISDE 2x4 (5)#12 (9)#12 2x5 (5)#12 (9)#12 2x6 (7)#12 (9)#12 2x7 (10)#12 (10)#12 2x8 (12)#12 (14)#12 2 x 9 (14) #14 (14) #14 2 x 10 (16) #14 (15) #14 DETAIL" K" GUSSET CONNECTION SCALE:NTS "ALTERNATELY SEE PAGE 5 � DETAIL "M" BEAM & PURLIN TO GUTTER CONNECTION SCALE:NTS WHEN BEAM & PURLIN HIT ON CORNER - FASTEN OUTSIDE OF BEAM & PURLIN w/ 1/8929Q" ANGLE & (4) #12 SMS EACH LEG FASTEN INSIDE CORNER (BEAM TO PURLIN) w/ 1/8"x2"x2" ANGLE w/(2) #12 SMS INTO EA MEMBER (BEAM & PURLIN) (9) #10#" SA 1/8" PLATE ON 45' ANGLE OR 1/BSQ'YL' ANGLE w/(4) #12 SMS INTO EACH INTERSECTING MEMBER PERIMETE FRAMING DETAIL "I.2" CABLE CONNECTION AT CORNER SCALE:NTS SAVE RAIL SECTION ATTACHED TO BEAM W/ (4) #10 X I-1/2' SMS INTO SCREW BOSS I IX2 FASTENED TO GAVE RAIL BEAMS FASTEN PER 1 ° SECTION W/#10 X 1-1/2' 1/6' STAINLESS STEEL DETAIL'E' SHT 3 0 SMS WITHIN 6' OF COL. MMAX BRAIDED CABLE PURLINS FASTEN PER HT DETAIL'G' S3 I ° o ° AND 24. 0/C 60° GUTTER BRACE AT EACH BEAM/ PURLIN COLUMN TO LOCATION. FOR BEAMS 2x8 AND GREATER MATCH BEAM/ INSTALL GUTTER BRACE AT MIDPOINT PURLIN SIZE BETWEEN BEAMS. 2'a2'XI/0• ANGLE nR2) #12 SIRS (U.N.OJ SEE EACH LEG PAGE-2 4" MIN. SLAB W/FOOTING 30DIAx3"E TO GUTTER CONIC. SCRE% r SMS D :H SIDE OF COL. (TAPCON OR (2) #14x2' WOOD 3000 PSI CONIC. (2) #12 SMS SCREW IS- O.C. 40' MIN 6x6-10x10 60° MAX. WWM OR FIBERMESH \ SIDE VIEW TRANSOM CONNECTION SCALE: N.T.S. x EQUAL) J DO m J rn co ZZp o U n/ W J 0 00 = J p W g LL L!) •L r 0) W ~ UI F M c IEBOLTFOR W < ABLETENSION Q Im STAINLESS STEEL BRAIDED CABLE Q < U N N 1..1� (D LL' O� r a 1J I..L 3000 PSI CONIC. 6x6-IOx10 W WM OR FIBERMESH 4" MIN. SLAB/ WFOOTING 1.5'x5.5'ALUM. STRAP w/(2)1/4" DIA x 2-1/4' MASONRYANCHOR (TAPCON OR EQUAL) DETAIL 1-1" CABLE CONNECTION AT FOUNDATION SCALE: NTS J' A LnL0 O CD O z U L LI i O Q. Of U U J } z m W ILI I--. UW ILL U)Of Ul 0 U� W Z o mzU < Wti0 DO w 0- 0- DATE: 04/1812019 N 1: DATE PAGE: N 2: DATE NTS 3/16" 5052-H32 GUSSET 2" X PURLINS ATTACH TO BEAM WITH MIN (4) 910 X 1 112" SMS PLACE WASHER UNDER SCREW IN GUSSET CORNER 11/4"(TYPICAL) o 50 2"X2"X11V ANGLE X 4" LONG PROVIDE #14 X 1" INTO EACH MEMBER AS INDICATED BELOW PROVIDE INTERIOR ANGLE ABOVE AND BELOW CHAIRRAIL EXTERIOR CORNER POST x2x SMS @ 1 1/4" O.C. NOTES: 1. GUSSET DIMENSION ARE MINIMUM (2) REDO (1) EA SIDE OF BEAM - MAYBE INTERNAL OR EXTERNAL 2. AS BEAM SIZE CHANGES, ADD OR SUBTRACT SCREWS TO MAINTAIN 1-1/4" C/C SPACING 3. GUSSET LENGTHS REMAIN CONSTANT WIDTHS CHANGE TO MATCH BEAM SIZE. RAIL _1"x2"O.B. PATIO SECTION 3" x 3" x 0.050" MIN., 6063-T6 ALLOY PLATE DR STRONGER (ONE SIDE) WITH (3) - #12 x 3/4" S.M.S. EACH SIDE AS iOWN (3/8" MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) K-BRACE LATERAL "IV' -BRACING CONNECTION DETAILS GUSSET PLATE PER ESERIES PURLIN 3" x 2" x 0.050" MIN., 6063-T6 ALLOY PLATE DR STRONGER (ONE SIDE) (3) - #12 x 3/4" S.M.S., EACH SIDE AS SHOWN (1/2" MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) ANGLE 1" INTO EACH ]ICATED BELOW CORNER (2) #10 X 1 1/2" SMS THRU SCREW BOSSES �YW1=616Ti100 NOTES: SEE PLAN 1. CONNECTION DETAIL AT EAVE RAIL SIMILAR MATING 6" 1" X 2" O.B. FASTENED TO CORNER POST W/ 912 X 1 112" SMS AT 6" FROM TOP & BOTTOM RAILS TYPICALLY @ 24" O.C. 1/8" X 2" X 2" EXTRUDE ANGLE 5052 H-32 ALLOY EA CORNER W/ (2) #14 X 2" SMS INTO POST & (1) 3/8' DIA CONCRETE SCREWANCHOR INTO CONCRETE 2114' MN CCNC SIDE VIEW CORNER K-BRACE DETAIL SCALE: N.T.S. (4) #14 X 3/4" SMS INTO POST 1" X 2" BASE PLATE ANCHORED TO CONC W/ 114" CONTRACTOR TO INSTALL CONCRETE SCREW ANCHOR (2) #14 X 2" SMS THRU BRACE (MIN. 1 1/4" EMBED) INTO BEAM THRU GUSSET 6" MAX EACH SIDE OF POST PLATE AND 24" O.C. MAX 1"X2"@ 3/8" X LENGTH AS REQUIRED FOR 2 1/4" EMBED CONCRETE SCREW ANCHOR INTO CONCRETE DETAIL #2 FRONT VIEW CP- CORNER POST TO CONCRETE DETAIL CORNER POST A -A SCALE: NTS 6" x 5" x 0.050" /' COLUMN 6063-T6 ALLOY PLATE VIBRACE -BRACE (ONE SIDE) OR STRONGER 2x 2x 0.093 BRACE (TYP.) K-BRACE x 2 x 0.093 (TY2 x 3 x 0.070 CHAIR RAIL O O O-- I O O O O GIRT (CHAIR RAIL) K-BRACE O O 3/8" 0 CONCRETE ANCHOR (2 PLATES) FOUNDATION IN LIEU OF TYP. 1/4" 0 CONCRETE SCREWS FOR CORNER COLUMN LATERAL "IC' -BRACING CONNECTION DETAILS 2 x2 x 0.093 13RACE(fYP.) (11 TOTAL)-#12 x3/4" S.M.S. AS SHOWN (1/2" MIN. PLATE EDGE DISTANCE & LATERAL "IV' -BRACING C-C FASTENER SPACING) w CONNECTION DETAILS AV (3) 1/4' DIA. MACHINE BOLTS f E: FOR DOUBLE OR TRIPLE CARRIER w/ 3/4' DIA. WASHERS THRU BEAM. OUTSIDE WEBS SHALL OVERLAP • CARRIER BEAM B POST 4xL POST OR NOTCH POST AS ABOVE FOR 60 POST. ALL CASES, CONNECT USING MACHINE BOLTS DECRIBED ABOVE. ® CARRIER BEAM E- 2' MEMBER FOR SCREENING VARIES (2) 2'A_ SHE HORIZONTAL BEAM (SEE PAGE 2 ON ITS SIDE FOR SIZE) #14M SHE 12. O.C. POST (IF REQUIRED) STAGERED ROWS `2-a2-x0.'62' \ TFOR SINGLE RECEIVING CHANNEL \\— HORIZONTAL BEAM OR ANGLE EACH SIDE 4- FOR DOUBLE HORIZONTAL (6) 1I04.75• SHE BEAM OR 4'x4' EACH SIDE \` (12) #BM0,75- SMS 2 ROWS OF (6) FOR RECEIVING CHANNEL OR (6) EACH ANGLE CARRIER BEAM TO POST DETAIL CONNECTION SCALE: N.T.S. (2) 3/0- CIA. EXPANSION BOLTS SEE NOTE #1 THIS PAGE FOR BOLT PLACEMENT Ned i9 2• FROM EDGE 2' FROM EDGE OF SLAB OF SLAB 2-s2' FASTENED TO CARRIER BEAM wIGN #ICxI-I/T SMS INTO SCREW BOSSES EACH END 2'x2'x.062 RECEIVING CHANNEL MAY USE 2-n2'x.1.25 ANGLE EIS CARRIER BEAM IN LIEU OF_062 REC. CHANNEL ROOF BEAM (SLOPED OR FLAT) O NOTE USE SIMILAR DETAIL FOR NOTCHED UPRIGHT CI CONNECTION TO CARRIER BEAM 1'#'MEMBER O FOR SCREENING-,,,,, O SI #12x3/4•SMS (TTP. EACH SIDE) (2) ROWS OF (5) #10A-1/2- SMS #12n3/4'SMS O.C. MAX CONNECTING TO I-x2- CARRIER BEAM NOTE: FOR DOUBLE OR TRIPLE CARRIER BEAM, OUTSIDE WEBS SHALL OVERLAP U4 POST OR NOTCH POST AS ABOVE #IDXI-1/2' SMS @ 24• FOR 60 POST. ALL CASES. CONNECT O.C. MAX CONNECTING USING MACHINE BOLTS DECRIBED ABOVE. TO I-XV POST ROOF BEAM TO CARRIER BEAM CONNECTION DETAIL SCALE: N.T.S. (2)1/2'DIA. EXPANSION BOLTS SEE NOTE 42 THIS PAGE FOR BOLT PLACEMENT \ 2', SMB /(SEE PAGE-2 FOR SIZE) 3-3/4- FROM EDGE OF SLAB (TV.) TOP VIEW TOP VIEW (2)1/C DIA, MACHINE BOLTS w/ WASHERS 4`x4' POST SIZE STITCH wl(D VARIES SEE PG 2 #12x3/L' SMS (3) 1/4'DIA. MACHINE 0 12'O.C. 3'x3' POST BOLTS w/ WASHERS (2) 3/8' DIA. EXPANSION BOLTS (SEE PAGE-2 FOR SIZE) 2's— SMB SEE NOTE #1 THIS PAGE (SEE PAGE-2 FOR BOLT PLACEMENT 3'x3'xO.125 ANGLE (2) UT DIA. EXPANSION FOR SIZE) BOLTS SEE NOTE #2 THIS PAGE FOR BOLT 2'X4'x0.125 ANGLE PLACEMENT • 3000 PSI CONIC. ' n SLAB/ FTG. 6x6HOMO WWM . g• 3000 PSI CONIC. OR FIBERMESH • n SLAB/ FIG. 6s6-10X10 WWM FRONT VIEW OR FIBERMESH FRONT VIEW 3"xY POST CONNECTION DETAIL SCALE: N.T.S. 4"x4" POST W/ 2x SMB CONNECTION DETAIL SCALE: N.T.S. NOTES: L 3X3 POST TO HAVE 3/8' RED HEAD - TRUBOLT WEDGE ANCHORS (STAINLESS STEEL, PROVIDE MINIMUM 2- FROM EDGE OF SLAB AND PROVIDE MINIMUM Z' SPACING TO ANY OTHER CONNECTOR. SEE MFG. NOTES FOR INSTALLATION REQUIREMENTS. THREADED ROD REQUIRES 3' MINIMUM EDGE DISTANCE. 2. 4X4 POST TO HAVE 1/3' RED HEAD - TRUBOLT WEDGE ANCHORS (STAINLESS STEEL, PROVIDE MINIMUM 3.3/4- FROM EDGE OF SLAB AND PROVIOEBMINIMUM }3/4- SPACING TO ANY OTHER CONNECTOR. SEE MFG. NOTES FOR INSTALLATION REQUIREMENTS. 3. WHERE PAVERS ARE PRESENT ANCHOR LENGTH SHALL BE INCREASED BY THICKNESS OF PAVER NOT TO EXCEED 2-1/2' FOR PAVER THICKNESS MORE THAN 2-1/2' SPECIFICATIONS SHALL BE REQUIRED. PAVERS SHALL BE BONDED TO UNDERLYING CONCRETE FOUNDATION. 4. WHERE RETURN WINDOW BEAM MEETS MASONRY WALL USE 1/8' U-CHANNEL W/ (3) 2-1/4' TAPCONS INTO WALL AND #14 X 3/4' INTO BEAM E/S QUANITY= BEAM SIZE O O V,E C91/4' DIA. MACHINE BOLTS RE w/ 3 DIA, WASHERS THRU Dj WRIER BEAM 8 POST PAST n: a ~ ' C O O d pip a 'y C � O � (� Q (3) I/4' 014. MACHINE W BOLTS w/ 3/A• DIA. CD LU RIER WASHERS THIRD WRIER t0 TOP VIEW - BEAM B POST Q CARRIER BEAM 0 v J 0 GO S m J # CARRIER BEAM p (y) (i) /L' DIA. MACHINE / n CY) BOLTS In/ 3/4• DIA. THIRD CARRIER v BEAM A POST Z L o QU U POST (5) I/4• CIA. MACHINE BOLTS w/ 3/4' CIA. WASHERS THRU CARRIER BEAM 8 POST FRONT VIEW CORNER CARRIER BEAM CONNECTION DETAIL SCALE: N.T.S. (4) 3/0'x4'TAPCON THRU BOTTOM LEG OF ANGLE INTO CONIC 3-3/4-FROM EDGE OF SLAB (TV.) - TOP VIEW (3) I/4' DIA. MACHINE BOLTS w/WASHERS - (4) 3/8'x4' TAPCON THRU BOTTOM LEG OF ANGLE INTO CONC. 3000 PSI CONC. SLAB/ FIG. 6x6-IOXI0 WWM OR FIBERMESH r Z 1' 4'n4-POST (SEE PAGE-2 FOR SIZE) -I/8-x2'AZ'x33/4• (LENGTH)ANGLE (INTERNAL) �r FRONT VIEW 4"W' POST CONNECTION DETAIL (INTERNAL BASE) SCALE: N.T.S. Q) I/2' DIA. EXPANSION BOLTS SEE NOTE #2 THIS PAGE FOR BOLT PLACEME 3-3/4' FROM EDGI OF SLAB (TYI 3-3/4' FROM EDGE OF SLAB(TYP.) TOP VIEW (3) IlW CIA. MACHINE BOLTS w/ WASHERS (2) I/2- DIA. EXPANSION 4W POST BOLTS SEE NOTE #2 (SEE PAGE-2 THIS PAGE FOR BOLT FOR SIZE) PLACEMENT --. \ II II � 2-AW.0.125 ANGLE Ir p U W O Go — W J11 L LLo ~_ L C /1'1 - 6j z 0 Q J d N Q c �♦/Cha-� U O n.�..F. of d V 0 O LL Z U_ W O LL J 3000 PSI CONIC. • J < SLAB/FTG. WWM Z6A6-IOXIO CO OR FIBERMESH W F FRONT VIEW W LU WLL 4"W POST CONNECTION DETAIL U) N Y SCALE: N.T.S. m U?) o W °o mZU H z Q W h c3 Y�d d w /1 J'ke p o �1 DESIGN DATE: 04118/201 9 REVIS12N PAGE 2: C NTS