Loading...
HomeMy WebLinkAboutHELICOOL COLLECTOR CONCRETE TILE ROOF INSTALLATIONHELIOCOL COLLECTOR-CON_Cke'I E TILE - TILE ADHCABLVDGENERAL NGTECOEFLORIDA BUILDING 6TH 1. EDITION) & ASCE-7-10 MINIMUM DESIGN -DADS FOR BUILDING AND OTHER STRUCTURES. 2. PLANS ARE IN ACCORDANCE WITH 2O17 F.B.C. (6TH EDITION) AND PER MIAMI DADE NOA 15-1201.04. 3. POLYPRO ROOF ADHESIVE SHALL BE APPLIED IN COMPLIANCE WITH THE COMPONENT APPLICATION SECTION AND THE CORRESPONDING PLACEMENT DETAILS NOTED IN THE NOA APPROVAL DOCUMENT AND THE 3M/POLYFOAM POLYPRO ROOF TILE ADHESIVE OPERATING INSTRUCTION AND MANUAL BOOKLET. 4. TILE ROOF INSTALLATION AND UNDERLAYMENT SHALL COMPLY WITH LATEST FLORIDA BUIDING CODE AND ROOFING APPLICATION STANDARD RAS 120. 5.3M/POLYFOAM POLYPRO ROOF ADHESIVE COMPLIES WITH THE FOLLOWING CODES: 2014 FLORIDA BUILDING CODE (5TH ED), SOUTH FLORIDA BUIDING CODE BROWARD COUNTY-1999, MIAMI DADE NOA 15-1201.04 6. LOCATION OF COLLECTORS WITH 3M/POLYFOAM ADHESIVE IS NOT TO BE INSTALLED IN WIND ZONE 3. 7. CONNECTIONS AND SPECS PER THIS DRAWING MAY BE USED FOR ALL HELIODL COLLECTORS TO RESIST WIND LOADS AS OUTLINED IN 2017 FBC, CHAPTER 16 FOR UP TO 175 MPH, EXPOSURES "B" OR "C' WIND VELOCITY PER REQUIREMENTS STATED IN ASCE7-10. 3M/POLYFOAM POLYPRO -NOA SPECIFIC NOTES: POLYPRO ROOF TILE ADHESIVE MUST BE APPLIED TO AN UNDERLAYMENT INSTALLED IN COMPLIANCE WITH APPLICATION INSTRUCTIONS DETAILED IN THE FOLLOWING LATEST DOCUMENTS: FRSA/ROOF TILE INSTITUTE ADHESIVE SET TILE SPECIFICATION 3M/POLYFOAM ADHESIVE IS UL CLASSIFIED AS AN ADHESIVE MIA„ VDADEN!0 5-1201A4, EXPIRES 1/03/2021. LIMITATIONS OF MIAMI-DADE NOA FOR SPECIFIED TILE PROFILE -ADHESIVE BELOW: 1) FOR ADHESIVE SET TILE APPLICATIONS, A STATIC FIELD UPLIFT TEST IN ACCORDANCE WITH TAS 106 MAY BE REQUIRED, REFER TO APPLICABLE BUILDING CODE. 2) APPLICANT SHALL RETAIN THE SERVICES FOR A MIAMI-DADE COUNTY CERTIFIED LABORATORY TO PERFORM QUARTERLY TEST IN ACCORDANCE WITH TAS 112, APPENDIXW. SUCH TESTING SHALL BE SUBMITTED TO THE BUIDING CODE COMPLIANCE OFFICE FOR REVIEW. 3) MINIMUM UNDERLAYMENT SHALL BE IN COMPLIANCE WITH THE APPLICABLE ROOFING APPLICATIONS STANDARDS LISTED SECTION 4.1 HEREIN. 4) THIS ACCEPTANCE IS FOR WOOD DECK APPLICATIONS. MINIMUM DECK REQUIREMENTS SHALL BE IN COMPLIANCE WITH APPLICABLE BUILDING CODE. TABLE 1: ADHESIVE PLACEMENT FOR EACH GENERIC TILE PROFILE PER MIAMI DADE NOA 15-1201.04 CONCRETE ROOF TILE PROFILE PLACEMENT DETAIL MINIMUM SINGLE PADDY WEIGHT (GRAMS) FLAT / LOW / HIGH PROFILE #1 AND #2 12 HIGH PROFILE (2 PIECE BARREL) #2 12 FOR HIP AND GABLE ROOFS - PLAN %1` 1"xZ"x2%"-1fi"ALUM. 6063T6 Z-BAR SHAPE WITH (1)14" DIA. -14" LENGTH TAPCON STAGGERED AS SHOWN THIS SHEET HELIOCOL COLLECTOI TYP I"x12"x21/z"-16"ALUM. 6063T6 Z-BAR SHAPE WITH (1) y' DIA. -1 y' LENGTH TAPCON STAGGERED AS SHOWN THIS SHEET END CAF TYP. TYPICAL SCALE: a° '5) COLLECTOR ARRAY PLAN ** CLAMP CONNECTION NOTE: 1. WHEN CLAMP FALLS OVER TILE: USE (1) a' DIA. -14' LENGTH TAPCON THRU Z-BAR INTO TILE. 2. WHEN CLAMP FALLS OVER VALLEY: USE (1) q" DIA. - 1" LENGTH ST. STL. BOLT - WASHER- NUT THRU Z-BAR REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC VIX Z' x 2 /" - lb" ALUM. 6063T6 Z-BAR SHAPE (30" MIN. SECTIONS) FASTENED WITH (1) q' DIA. -14' LENGTH TAPCON 12" O.C. 1 22 I 32 TYPICAL Z-BAR DETAIL SCALE: 1 Z'=1'-0" V O CV 1" x Z' x 2 %" -16" ALUM. 6063T6 Z-BAR SHAPE TYP TOP &BOTTOM OF COLLECTOR WITH (1) q' DIA. -1 y' LENGTH TAPCON STAGGERED 12 O.C. (SEE Z-BAR DETAIL) (2) #6 HEX SCREWS 1 - 4 LENGTH TYP CLAMP CONNECTION - SEE NOTE ** FLAT CONC. TILE TYP. 1" x 12" x 2 %" -16' ALUM. 6063T6 Z-BAR SHAPE TYP TOP & BOTTOM OF COLLECTOR WITH (1) q' D1A, _ 1 ? 4 LENGTH TAPCON STAGGERED 12" O.C. (SEE Z-BAR DETAIL) (2) #6 HEX SCREWS 1" 4 LENGTH TYP CLAMP CONNECTION - SEE NOTE ** � 1" x 12' x 2 Y2" -1fi' ALUM. 6063T6 Z-BAR SHAPE TYP. HELIOCOL CLAMP SPACED 2-0" O.C. q' DIA. - 1.q' LENGTH TAPCON STAGGERED 12" O.C. TYP. SCANN�I� HIGH CONC. BY TILE TYP. St. Lucie COU11 a Z O a o a N APPLY 3M/POLYPRO ROOF TILE APPLY 3M/POLYPRO ROOF TILE f7TRUSS SY.P. ADHESIVE, OR EQUAL, TO ADHERE #2S.Y.P.ADHESIVE, OR EQUAL, TO ADHEREOD ROOF WOOD ROOF TYP. BOTTOM SIDE OF TILE HELIOCOL TRUSS TYP. BOTTOM SIDE OF TILE HELIOCOL c CLAMP IS ABOVE TO PLUS ALL CLAMP IS ABOVE TO PLUS ALL 19D5 -O[OJ SHEATHINGWOOD SHEATHING AROUND IT (5 MIN.) WOOD SHEATHINGTILES AROUND If (5 MIN.) TYPICAL Z-BAR - HELIOa4 TYPICAL FLAT / LOW PROFILE CONCRETE TILE _ TYPICAL HIGH PROFILE CONCRETE TILE _ CLAMP CONNECTION ADHESIVE TOP & BOTTOM CONNECTION DETAIL SCALE: 1"44' ADHESIVE TOP & BOTTOM CONNECTION DETAILr 4 SCALE: 1"=V-0" DETAIL SCALE: 1/2' �w z U � Z as U � �� ZDs L a 1 ,z ToFo W U Q' N F J LU Q U] 0 w Q U 8��Gb oU,, �ZH¢OO wOwo�ce = U m a n SCALE APR 0 9 2018