PLANS
sting storefront remain \ Existing storefront to remain Existing storefront Existing storefront to remain \ FRONT ENTRANCE Existing storefront to remain I I _ I I I � I I - � I I � - I I Provide new (3) 48% x 36"h L - fixed tempered glass windows --I�l _J I Each Box represents one arcade machine � I I I l7 I - J EXISTING TENANT SPACE _ z CE I N I - -1 ARCADE - _ _I I I _ I � I F- Provide new (3) 48% x 36"h - fixed tempered glass windows 1 6 I _I I I I � I I I F- - 5'-4'I ; L_ EN �I i ry 1 � I I F-I f -F-I F -F-I 1-- I I I I I I I I I I I I I I I I I I I I I 1 '�7-*Each Box represents I one arcade machine \ I - I I I I I I I I I I I Each Box represents 1- - I -I one arcade machine I --I I_J_J I_J_J I_J_J r-- I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I EXISTINIG TENANT SPACE I I 1 I_J_J I_J_JI- I I I I I I 1 I I I I I I I I I I I I I ARCADEI-- 1 I I I I I I Existing Column I 1 1 Provide new 6O% x 36"h to remain _ _ tempered glass Horizontal 1 roller window DASHED LINES -f--" I I I I I 1 I 1 EQUAL ARCADE -�EQUIPMISNT I_J_J _J_J I_J_J I I I I I I I I I counter top.high o n I I I I I I I I I 5 I 1 1 I I I I I 1 Provide new 36"w x 36 h fixed tempered glass win ow - - I SEE BATHROOM I 1 1 DETAILS ON SHEETI I I I I I 42 -J_J _ _ I 5'-1" Provide new Hi/Low water fountain field verif � y Base Cabinets see detail on sheet 42. to match existing below 36" high 1 stoappp-eed counter t0 ate.?.. steel p I i --� Ink i STORAGE 10- _ & W MEN E remove and cap existing water closet Existing exit , door to remain FLOOR FLAN I DWOMEN Existing exit - door to remain CONTRACTOR TO REPLACE ALL BATHROOM FIXTURES WITH NEW ADA SIZED FIXTURES TO COMPLY WITH CURRENT BUILDING CODE. TYPICAL NOTES: I. Contractor to verify ALL notes and dimensions prior to proceeding with work. 2. Contractor to STRICTLY enforce ALL OSHA Requirements. 3. ALL Lumber to be used as Beam, Rafters, etc.,. to have a minimum 1,400 P.S.I. fiber stress. 4. No dISSlmilar metals to touch. S. ALL Concrete used for slab repair shall be 2500 PSI concrete. 6. ALL wood in contact with concrete shall be pressure treated. 1. ALL wall dimensions are nominal and not finished Wall or stud dirrensions. 8. ALL plumbing fixtures to be low flow. 9. New Walls and Ceiling finishes shall have a flame -spread classification of not greater than 200 10, New Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 11. All exposed attic Insulation materials installed on attic floors shall have a critical radiant flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation materials exposed on the underside of the roof deck or on the attic walls shall comply with F.B.C. Residential Section R314 - see permit info box of code edition 12. Gyypsum board material shall conform to ASTM C36, C19, C415, C514, C630, C931 C960, C1002, C1041,C1111, C1118, C1218, C1395, or C1396 and shall be installed according to the following: Existing Janitors Closet Existing hand sink to remain Existing utility sink to remain XIS�IN MIENSaA ACCESSI� ° Provide one new layer of 5/8" type "X" Drywall For increased fire resistance. Q1 Provide new 48% x 36"h drywalled opening to match existing windows EXISTING TENANT SPACE a Existing window to remain LOBBY/WAITING Provide new 48% x 36"h drywalled opening to match existing windows Provide new 60% x 501 tempered glass Horizontal roller window 18% x 64"I x 36" high counter top per F.B.C. II-1.2 See detail on Demolition Plan 12'-6" 42" high counter top 36" high counter top 42" high counter Provide one new layer of 5/8" type "X" Drywall for increased fire resistance. CASHIER EXISTI OFF' / Pro de one to X" Di CONTRACTOR TO REPLACE ALL BATHROOM FIXTURES WITH NEW ADA SIZED FIXTURES TO COMPLY WITH CURRENT BUILDING CODE. Drywall Thickness Location Orientation Framing Member Max. spacing fasteners Nail sizingoptions for p Spacing of installation of dryywall into Nails Screws Maximum wood framing membera 2" x min. thickness Ceiling Perpendicular 24" 712' 13ga 1 3/8" long with 19/64" head OR 0.098" diameter x 1 1/4" long �2 annular -ringed or 5d cooler nail OR 0.0880 x 1 5/8" long with Walls Either 141,alli6" on h died. OR Ggpsum board nail 0.086" din. x 15/8" with 9/32" head. Ceiling Perpendicular 24" 12" 13ga 1 5/8" long with 19/64" head 0.098" diameter x 1 3/8" long 6 annular -ringed or 6d cooler nail OR Walls Either I6" 8" I6" 0.092" dia. x 1 1/8" long with Direction 1/4" head OR Gypsum board nail 0.0915" dia. x I l/8" with 19/64" head. u layer of 5/8" II for increased z O c N ()T U z� `[ z N 0 W Existing exit door to remain SCALE 1/4" = I'-O" FRONT SIDES O.N9 sl�sr ----- RI-An - 13. Insulation Including facings such as retarders or vapor permeable members installed within floor -ceiling assemblies, roof -telling assemblies, wall, crawl spaces and attics shall have a flame spread index not to exceed 25 with an accompanyin smoke developed index not to exceed 450 when tested In accordance with ASTM E 84. Insulation shall comply with F.B.C. R316. THERE IS NO MECHANICAL WORK TO BE DONE. EXISTING SHALL REMAIN AS -IS, SITE ADDRESS: 110 S. US HIGHWAY I, PORT ST. LUCIE, FL. Square Footage Calculation Net Square footage = 2,617 sq. ft. Total of Bathrooms Partitions etc... = 1,150 sq. ft. Total Square Footage sq. ft. OCCUPANT LOAD 2,611 sq. ft. (net) / Is sq. ft. per person = 118 persons (A-3 Assembly with tables and chairs) Including cashier and existing office spaces PERMIT INFORMATION rO THE 2001 iUPPLEMENTS t�vrx wino IJE5IGN, TH15 PROJECT HAS BEEN DESIGNED AND SHALL ADHERE TO ASCE 1-05 WHERE EXTERIOR WORK IS SHOWN ON THESE PLANS. ELECTRICAL SHALL COMPLY WITH THE 2008 EDITION OF THE N.E.C. THE OCCUPANCY TYPE SHALL BE: A-3 ASSEMBLY THE CONSTRUCTION TYPE IS: TYPE II B THIS BUILDING IS NOT SPRINKLERED THE EXISTING ROOF STRUCTURE IS AS FOLLOWS : `(QV = LIGHT -FRAME TRUSS TYPE CONSTRUCTION - ROOF ONLY SITE ADDRESSES SHALL BE PLACED CONSPICUOUSLY ON THE FRONT OF THE STRUCTURE, SO THE NUMBERS CAN BE SEEN PLAINLY FROM THE STREET NUMBERS SHALL NOT BE LESS THAN SIX INCHES IN HEIGHT MINIMUM WALL t CEILING FINISHES PER F.B.C. TABLE 803.5 GROUP: A-3 NON-SPRINKLERED Exit Enclosures t Passageways: A Corridors: A Rooms t Enclosed Spaces: C Door Schedule Mark Size Door Description A Existing Re -hang door as shown on floor plan (swing out at bathrooms) B (2) 3'-0" X 6'-8" TEMP GLASS FRENCH DOORS C 3'-0" X C-8" Solid Core Wood door with 1/2" light window Contractor to provide new A.D.A. Lever hardware at all Interior doors Contractor to verify all existing panic hardware is operable and if found non -operable or damaged, contractor to replace with new. Contractor to verify all existing auto closers are in good working order. If found non -operable or In disrepair, contractor to replace with new with new. ST. LUCIE COUNTY PLAN REVIEW BLDG: DATE: ELEC: DATE:/ MB DATE: F"� DATE: MECH. DATE: room floor base walls ceiling clg. height Arcade Carpet VCT drywall Existing Acoustical Existing 9 " 10'-0 Lounge Carpet VCT drywall Existing Acoustical Existing 10'-0" Cashier Carpet VCT dr wall Existing Acoustical Existing 0 10'-0" Office Carpet VCT drywall Existing Acoustical Existing 5 10'-0" Bathrooms VCT VCT drywall Existing Dr wall Existing ® 8'-0" Janitors Closet VCT VCT drywall Existing Drywall Existing 9 8'-0" Notes. 1103- 0 SCABYE® 1. ALL trim to be high gloss white 2. Allow for 3 different Interior paint colors St. Lucie County 3. Paint to be Beniamin Moore or equal. Walls to have 3 coats. -4. VCT Base to match existing - repair existing where needed. S. Carpet Allowance: $15.00 per yard Installed 6. VCTAllowance: $10.00 per and Installed 7. Owner to specif( carpet It tl�e colors prior to construction S 0 -_ 1 13 g U v m n/ ��'oUvCl U T ® L)IL v v I O LL +-1 C Q) E `o O ULL L 1 1-JL- IV � C Etl u +- N � U � U < (L c+l .0O ao m N O v to oo la O "" u j I I UQ Q 0- Q or0 OD # 2 Q) i cv cv E C (6 W O CA C4 � a- L 4j r- r- a- rD t! U cn rt lja L ELL. I v w10 *' t- 0) Sheet l . OF 6. Comm # 11-20 Existing struct aaUS II II II II II II II Remove wall as needed for new window location I I II � II — II II II II II II II II Remove wall as needed I I for new door location II II II II FIELD VERIFY ROUGH OPENING SIZES PRIOR TO DEMOLITION WITH WINDOW AND DOOR MANUF. I II II II II II II Remove wall as needed I I for new window location I I i I � II — II II II II II II I l � Remove existing walls as shown BATH OD :4 BATH Contractor to re —hang existing doors as shown on floor plan. Demolition Plan WALL X X W 0) \ OD C ORIFICE m HEIGHTS m r Existing column to remain Remove existing door =�eld venfg Existing cased opening to remain. Raise header up to l'—O" a.f.f. Remove existing — _ walls as shown — �' L D EXISTING JANITO 48" Min. BATH vx BATH Contractor to re as shown on floor SCALE 114" = 1'-0" Floor Mm. �in. Water Fountain Spout Height and Water Fountain Clear Floor Space Detail Knee Clearance Detail NTS NTS Water Fountain Notes: — Water Fountain spout shall provide a flow of water to allow the insertion of a cup or glass under the at least 4 inches flow of water. On high so as an accessible h r O V I c e n e W E l k a q drinking fountain with a round or oval bowl, the spout must be positioned so the flow E Z S T L 8 C Hi/Low of water is within 3" of the front edge of the fountain per F.B.C. II-4.15. Water cooler. - Fountain shall comply with F.B.C. P410 existing doors Existing window to remain II I I Remove wall as needed I '?--- for new window location II I FIELD VERIFY ROUGH OPENING SIZES PRIOR TO DEMOLITION WITH WINDOW AND DOOR MANUF. I I Remove existing wall I II II Remove existing window / / .41 Remove existing door I I II II II o III III ~ E rah E = ICI �$ 90 ICI ICI v QIic I � Remove existing window II II II II I� Existing door to remain EXISTING BATHROOM r 0 EXISTING OFFICE Existing ceiling to remain—,/," Provide new LO"w x 50"h tempered glass Horizontal roller window . ACCESSIBLE COUNTER DETAIL 1/2" = 1'-0" Existing in ulati n existA structur Existing Suspended acoustical ceiling R—II batts insulation between n3 bathrooms t hallways. � O 2"x4" wood blocking to be us U — metal fire block elsewhere I Q LLI w � X Cn U_i Q 5/8" drywall on 1 5/8" x 3 22 ga. metal studs existing slab base to match existing w T4pical Interior non—bearin Cd" — units and at ed for grab bars 5/8" wall Detail NTS Bar N.F.F. Tgpical Accessible Bathroom Detail 1/2" = 1'-0" Topical Bathroom Notes: I. Toilet paper Holder = American Specialties model # 0263-1A contractor to provide blocking so holder is 19" A.F.F. 2. Mirror = American Specialties Model # 0535-1830 fixed angle tilted mirror ( 18" x 30") insert size code = A Contractor to provide blocking so mirror will be 40" A.F.F. ( max.) 3. 36"long grab bar = American Speclaltles Model 43800 using type OI configuration as shown in details. 4. 42"long grab bar = American Specialties Model #3800 using type 02 configuration as shown In details. 5. Walls within 2 feet of urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of 4 feet above the floor and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. L, THIS MATERIAL SHALL BE F.R.P. BOARD AND SHALL BE ON THE PLUMBING WALL AND THE WALL TO THE RIGHT OF THE TOILET AS YOU WOULD FACE IF SITTING ON THE TOILET. w C] I 0 v fill 4J�'oUuC] I T o U Q E L E t A v I OL N 4' V Y 9- Min N tvI I oQ 000 Oro # N pNNp0' � +' urr,c6- CQ v ° r'✓ � tr �V� m a to lL Q E LL I Q� 4tl ,J L T v 7 ri, Sheet 2. OF 6. Comm # 11-20 Existing exit light to remain Swap out existing exit light with new fixture which shall include emergency battery backup lights \ Contractor to verify all existing life safety devices are in good working order. If found to be defective, contractor to replace with new. ENTRY DOOR vAFK__R Provide if none currently exists. Field verify prior to ordering v� I NEW TLETS 5 WIN \ AR N ADDITI TO I\ E TING TO EMAIN - I Provide TV Jeck must 1'26' a.1T / Existing battery t light to remain / EXIST G o TEN NT SP C E to new circu to new cult in panel "A" I /pa "A" CADE / I` V Jack end 6nfcu.1. I - 1 I 'OL / R£ IN A ETSHN ITIONT O / - XISTIN O REMAIN / Ti it 6 I IL - 14 1 I I/ I I� - 1 \ to new rcult in pan „A" L - I ` ton circuit Inr MEN 0� nel "A" EXISTING PANEL "A" w r� v I M O 'I Li I I I I II- I III II I I / I it I_ I I I \I II I `I " NEW OUTLETS SHOWN I I IN III / EXISTIARE NG TOIOEMAN I I - 1 T rorids TV Jack and outlet T-V m1.1. 11�11 I I/ I I I_ 4 \�to new circuit I /� I I anal B" �n emove existing rec ',,-for door taclesl _ -I r new openinwi� - -� I I I 1 1 1\\ I o to new clrcultl n panel "IS I II'-O" II Prwide TV Jack and I outlet T'-6' �T �ll I- DASHEr) LINES -f-,/EQUAL I I I I J IT - EQUIPMENT PMENTCADE I -� - \ I I 1 I I I I II I I I I 11 5 II NEW ARE NU AD TIONT O I \ - 1 - EXISTING TO REMAIN I I /� 1 I I to new circuit in panel i,B„ 1 J - - Swap out existing exit light with new fixture which shall include emergency battery backup lights ELEC7RIC/4L F'L/4N STORAGE EXISTING PANEL "B" O WOMEN Existing exit light to remain Electric Power pole dropped from telling Swap out existing exit light with one duplex receptacle For gaming with new fixture which shall / machlneal - 1 inch emergency battery backup hghkks I I I I I I I /I I II l I NEW OUTLETS SHOWN ARE IN ADDITION TO I l l EXISTING TO REMAIN 1 LI- I I III I I III I I I I \I I I \I I I III I I III I I � I I_JL I_JLJ I L -4I/ I 1 - H i EXISTING/IFEI'IANT SPA(I�E I I 1 ', -� ACADE/1- ' I \\ I to new circuit in a elI I`\ I �/ p I I I p I I I to m panel new clrpoul i- t t 1 o new circu) I In anal "C" I /=XlrT.Ing/ I I column to I I I -- remain I -- /I I_IJ_J 1 11 1 I 11 I I I ,I I rl -1 III I II I >1 III I I Relocate existing I I - - J I I - - I J thermostat in new uall \ \jto new circuit 1n panel "C" to new circuit T Relocate existing in panel "D"_ _ electric to new wall location to new in panel circuit "C" n I ti'rti'r) time / II II 1T) II------- ILIL9"nL�ll -Existing exit light to remain Contractor to verify all existing life safety devices are in good working order. If found to be defective, contractor to replace with new. Existing Janitors EXISTING Closet in new circu PANEL "C" n panel °D" Swap out existing exit light with new fixture which shall include emergency battery backup lights ELECTRIC NOTES: SCALE: I/4" = I'-O" I. Use copper wire only, no aluminum. 2. Contractor to verify location of electrical service and provider 3. ALL Branch Circuits that supply 125v Single phase 15 amp or 20 amp outlets shall be protected by an Arc -Fault Circuit Breaker 4. New receptacles shall be Tamper resistant AFCI. 5. ALL receptacles located in bathrooms or within IOft of sinks to be GFI protected. 6. ALL EXISTING BATHROOMS HAVE EXHAUST FANS. CONTRACTOR TO VERIFY THEY ARE ALL IN PROPER WORKING ORDER AND SHALL BE REPLACED IF FOUND OTHERWISE. 8. Contractor to repair/replace any existing panel, electrical device, light fixture etc... with any defect. THERE IS NO MECHANICAL WORK TO BE DONE. EXISTING SHALL REMAIN AS -IS. FK13 Fire Department Knox Box Q = Fire Extinguisher mounted �O" A,F.F. Extinguishers to be ABC - UL 2AIOBC SITE ADDRESSES SHALL BE PLACED CONSPICUOUSLY ON THE FRONT OF THE STRUCTURE, SO THE NUMBERS CAN BE SEEN PLAINLY FROM THE STREET NUMBERS SHALL NOT BE LESS THAN SIX INCHES IN HEIGHT ELECTRICAL SCOPE OF WORK: FeXISTING MENS BATHROO Swap out existing exit light \ with new fixture which shall include emergency battery backup lights Provide new TV jack EXISTING TENANT SPACE rovide new TV jack LOBBY/WAITING Remove existing outlets from removed wall el( l(1 u u 11 ��) 1LL11 1LL) 1 l.Il�)1TVI .lL .IL• .IL L Reuse existing circuits from removed outlets in new walls CASHIER Provide new x1t light fE EXISTI 0FFIC,f Provide new TV jack Reuse existing circuits from removed outlets in new walls Provide new TV jack :ate existing Jack Electrical S mbol Legend S Single Palo Switch ® 1 Recessed Can Light Sa Double Palo Switch ® E eboll Redeemed Can Light So Doctor Batch -0- Exhaust Pan Is Fall Button Batch ¢ Coding Mounted Light Duplex outlet C- Wall Mounted Light Special Rsceptacle Light with Pull Chem (aloe) Waterproof, ground fault mtermpte © Computer Connection Jack ® Floor Duplex Outlet 4& Flax! Light ® Junction Box m Electrical Penal (D Thermostat 8 Electrical Motor ® Central Vac A/C Disconnect ® Smoke Detects• � Calling Fen ® Televisor Jack Telephone Jack ® 2 x 4 Florescent Light ® I x 4 Florescent Light © Irtercen ® Speaker Hook-UpO Calling Mounted Light Dame Style + Pendent Light ® Motion Detector ( eldest light ) ® Carbm Mancoade Detector (2) Quad-plax outlets r7xisting battery backup light to remain i XISTING EXISTING ANEL "D" SUB -PANEL EXISTING PANEL E Swap out existing exit light with new fixture which shall include emergency battery backup lights ONE NEW CIRCUIT TO BE ADDED TO PANEL "E" FOR NEW LIGHTING - SEE SHEET RC -I. CONTRACTOR TO RELOCATE EXISTING OUTLETS AS SHOWN DUE TO NEW PARTITION LOCATIONS. - CONTRACTOR TO PROVIDE NEW TV JACK LOCATIONS IN LOUNGE FIELD VERIFY EXACT LOCATIONS WITH OWNER AND EXISTING RECEPTACLE LOCATIONS. - REPLACE EXISTING EXIT LIGHTS WITH NEW EMERGENCY BATTERY BACKUP LIGHT/EXIT LIGHT COMBO PACKS AS SHOWN. - EXISTING ELECTRIC NOT SHOWN BUT IS SUFFICIENT FOR NEW USE AS IS. PANEL "Bin Poles SR Load Win Dewriptim cited circle Description Woe Lead BR Pdss 2 40 4.7 kw #8 2 Ton A/C carp 1 2 AHU #10 2.3 kw 30 2 3 4 2 30 4.5 kw al0 40 gal. water HTR 5 6 Exhaust Fan #12 .a kw 20 1 1 8 Lighting #12 20 1 1 20 U12 Rece Pt. 9 10 Exist t Emargancy #12 20 1 1 20 a12 Reca is 11 12 New Receipts *12 20 1 1 20 U12 Bathroom GFI 13 14 HadRecasts #12 - 20 1 spare Is 16 New Receipts #12 - 20 1 spare 11 Is spare s are 19 20 s are spare 21 22 Spare s are 23 24 spare spare 25 26 s are b are 21 28 5 are s are 29 3° s are s are 31 1 32 spare PANEL "B" LOAD CALCULATION SHEET Load Description 0 ty,. Watts Total(Watta) General_.Lighting..(3. watts_,?9,.It.),Including,maw,..,..,,., Existing. Exhaust ,fan ,,,, .. , Exiating , Water Heater . .......... . _ _ , . , .. 133 3 2.199 1 200 BOO 1 4,500 1,600 Total Watts 11499 First 10000 Watts e100% 1,499 1499 Remainder O e40% O O Electric Heat or A/C 965% 10,000 4,500 Calculated Load Watta 13.999 Voltage 240 Calculated Wattage Divided by Voltage = Total Amps 58.32 IOOA Panel exists Panel Size Required = IOO Amps PANEL "D" Poles BR Load Wire Description cuc# cmc# Description Wire Load BR Poles 2 40 4.7kw #e 2 Ton A/C camp 1 2 AHU #10 2.3 kw 30 2 3 4 2 30 4.5 kw #10 40 gal. water HTR 5 L Exhaust Fen 012 .8 kw 20 T a Lighting 412 20 1 20 412 Race to 9 10 Exist t Emergency #12 20 1 1 20 tt12 Rece to 11 12 New Roseate #12 - 20 I 1 20 912 Bathroom GFI 13 14 New Recepts #12 - 20 I spare 1s 16 New 20 I spare 11 Is eitsm #12 - 20 1 5 are 19 20 spare spare 21 22 5 are 23 24 Spare 5 are 25 26 mare 21 28 b are 5 are 29 30 s are s are 31 32 s are PANEL "0" LOAD CALCULATION SHEET Load Description Qty. Watts Total(Wetta) ,General,.Llghting..f3_ wetts..aq..ft.),Including new Existing,Exhaust.fan Exiatmg.Water Heater. ..... ........ ......... New Water fountain ........................ ......................................... 133 3 2,199 1 1.200 Boo 1 4.500 11,500 1 Soo Soo Total Watts 8,299 First 10000 Watts 9100% 8,299 8,299 Remainder O 040% O O Electric Heat or A/C a65% 10,000 4.500 Calculated Load Watts 14,199 Voltage 240 Calculated Wattage Divided by Voltage = Total Amps 61.66 IOOA Panel axiets Panel Size Required = IOO Amps PANEL "A" Follow BR Load Wire Description arc% arc# Description Wire Load BR Polo 2 40 4.1 kw #8 2 To, A/C camp 1 2 AHU 910 2.3 kw 30 2 3 4 2 30 4.5 kw #10 40 gal. water HTR 5 L Exhaust Fan #12 .8 kw 20 1 l a Lighting #12 20 1 1 20 U12 Reca is 9 10 Exist t Emergency #12 20 1 1 20 #12 Rece is 11 12 New Rail #12 - 20 1 1 20 212 Bathroom GFI 13 H Mm Recopts #12 - 20 1 1 20 1.40 kw #12 AIR PURIFIER IS IL New Receipts #12 20 1 s are n Ia s are s are 19 20 slate s are 21 22 s are s are 23 24 s are s are 25 26 s are _5H] s are 21 20 s are s era 29 3o s are spare 31 3? 5pare _ PANEL "A" LOAD CALCULATION SHEET Load Description Qtli. Watts Total(Watts) General Lighting (3_ watts.sq..ft.) Including new. Existing Exhaust fan Existing Water Heater 133 3 2.199 1 1,200 BOO 1 4,500 4,500 Total Watts 1.499 First 10000 Watts e100% 1.499 1499 Remainder 0 e40% O O Electric Heat or A/C 865% 10.000 6,500 Smoke Eater 1.680 11680 Calculated Load Watts 15,619 Voltage 240 Calculated Wattage Divided by Voltage = Total Amps 65.32 IOOA Panel swats _ Panel Size Required = IOO Amps PANEL "C" Paid. BR Load Wire Description circa tutu Description Wirs Load BR Palo 2 40 4-1 kw #8 2 Ton A/C comp 1 2 AHU #10 2.3 kp 30 2 3 42 30 1.5 kw pIp 40 gal. water HTR s 6 Exhaust Fen 012 .e kw 202 8 Lighting 201 1 20 #12 Bathroom GFI 9 10 Exist t Emergencg #12 20 1 11 12 Had Receipts #12 20 1spare are 14 NRacapt•s 812 20 1 s are 15 16 spare s re 11 1e spare are 19 20s spare spare 2122 Spare spare 23 24 spare are 25 26s 5 are re adf 23e° s adrf ares Stare 31 se PANEL "C" LOAD CALCULATION SHEET Load Description Qty. I Watts Total(Watts) General Lighting (3. walla aq, ft.),Including,new ,. ,. Existing. Apust fen Ewating.Water Heater 133 3 2.199 1 1200 Boo 1 4500 4500 Total Watts 1,499 First 10000 Watts 8100% 1,499 14gq Remainder O 040% O O Electric Heat or A/C e65% 10,000 6,500 Calculated Load Watts 13,999 Voltage 240 Calculated Wattage Divided by Voltage = Total Amps 58.32 IOOA Penal swats Panel Size Required = IOO Amps PANEL "E" Pdee BR Load Wire Description We tire Description Win Load SR Poles 2 40 4.1 kw #6 2 Ton A/C comp 1 2 AHU a10 2.3 ku 30 2 3 4 2 30 4.5 ku #10 40 gal. water HTR 5 6 Exheuet Fen pl2 -8 kw 20 1 8 Lightmg #12 20 1 1 20 #12 Reco is 9 10 Ewet r Emergency #12 20 1 1 20 U12 Reca to 11 12 NEW LIGHTING 012 - 20 1 20 412 Bathroom GFI 13 14 spare Spar is 16 spare s are 11 Is spare spare 19 20 Spare spare 21 22 s are s are 29 24 spare spare 2s 26 s are spare 21 28 s are s are 29 30 5 are s are 31 32 s are PANEL "E" LOAD CALCULATION SHEET Load Description Qt . Watts Total(Watts) General Lighting (3, watts sq. ft.) Including new Exits ing,Exhaust fan Exiating.Water. Heater 133 3 2,199 I 1,200 800 1 4.600 4.500 Total Watts 1499 First 10000 Watts 8100% 1,499 1.499 Remainder O 040% O O Electric Heat or A/C e65% 10,000 4.500 Calculated Load Watts 13,at99 Voltacie 240 Calculated Wattage Divided by Voltage = Total Amps 58.32 IOOA Panel exists Panel Size Required = IOO Amps ;15 to a - I Z" Q =3 _D ''"'o��Q T to Q /t V v� OL Q LL 4' E _ `o > U LL Q 31 IV c E l�l U 4-3 JJ----11----// U U n<n (L e1` QI c Dom W Lf) OD 0) ID C (N c`! C oD DO U E > I I f�- Q t- oo Do U J as L_+'Urr,D N 6 CJ" %J1 o t# L � 10 E Q LL I Lu Sheet E1 OF 6. Comm # 11-20 sanitar Lire Flan �...���... .. .......�I un� as wii ua nc.cucu and cap plu�mbin�,g in Wall SCALE 1/4" = 1'-0" PLUMBING FIXTURE CALCULATION: Total Occupant Load = 178 persons/2 = 89 persons per sex. Per FBC P403.1: REQUIRED MALE I FEMALE Water Closets: I per 125 1 I per 65 Lavatories: 1 per 200 persons Drinking Fountain : I per 500 persons Service sink: I Required PLUMBING SCOPE OF WORK: PROVIDED MALE -FEMALE 2 2 2 male 2 male- 1 hi/low fountain I rovided - CONTRACTOR TO EXTEND EXISTING DRAIN AND WATER LINES AS NEEDED FOR NEW TOILET LOCATIONS - CONTRACTOR TO EXTEND EXISTING SINK DRAIN AND COLD WATER LINE AS NEEDED FOR NEW WATERFOUNTAIN INSTALLATION - CONTRACTOR TO CAP EXISTING WATER � DRAIN LINES AT NEW STORAGE ROOM WHERE EXISTING BATHROOM FIXTURES ARE TO BE REMOVED. - CONTRACTOR TO REPLACE ALL EXISTING FIXTURES WITH NEW A.D.A. APPROVED FIXTURES IN ALL BATHROOMS WHERE EXISTING ARE NON -COMPLIANT. Existing water lines o ranem Dashed lines represent existing hot water piping I�r I mckrlow Preventor auto ter line I fa nest I�Fpr rtion low shut off valor Remove existing toilet �c�water Ime as needed Cap satin J hotwater line H MIA location I as nseded.ls/ TOILET connect new wat to existing Mark TYPICAL TOILET ROOM WATER LINE EXTENSION extend hot t cold Irna as needed for new Existing water lines Sink locationto to renarn Provide backflow Preventor �� P l��! \� J Provide new shut off valve at now Sink location Emstx� o- Em•wry Jamtas I. LAV areas" 8iNt to r•nan JANITORS TYPICAL TOILET ROOM WATER LINE EXTENSION r water line✓ i EXISTING HOT WATER HEATER TO REMAIN AND 15 CURRENTLY OVER THE JANITORS Existing water line to emoting oink removed. Contractor to provide backflow Preventor if none exats. Field .venfg. Contractor to add shut off valve if rare exalts. Field venfg. or rountam cold water line WATER FOUNTAIN WATER LINE WORK g Cold Water Piping Water Hammer Arrestor — — — Hot Water Supply (IIOm) Tempering and Pressure relief Valve Conformina with ASTM Z21.22 Flow Direction Cold t Hot water Cold Water Pipe Size -0410.- Watts RP2-919 Backflow Preventor Hot Water Pipe size Check Valve Typical water shut off valve Ball Valve NOTES: - ALL Water pipe to be "L" Copper Pipe - Store all hot water at 140OF in water heater — Temperature limiting device which shall conform to ASSE 1010 with a max. max. temperature of 110 per F.B.C.P. 6011 - Verify all existing pipe diameters (where applicable) prior to ordering valves. - ALL through wall vents shall terminate IOft. above average ground level and shall be protected Trom birds and rodents entering or blocking vent openings per FBC P 904.6 Existing; Extend existing J'L for I vent new location toilet z1 XISCIKg la lose -I v. I 2" VTR I� 12 Cap as needed 1 2 1 Emoting Janitors Sink 2" Extend existing JANITORS CLOSET drain lint as needed for future sink C.anuat ea FUTURE SINK SANITARY RISER Extend existing / drain line as needed Existing dram lines for new toilet location Existingto remain we -I To be Removed TYPICAL BATHROOM to exsting SANITARYRISER sewer service nts 2XIVTR JiL _ I nts I Remove Existing sink a/ dram lines as needed existing vent to remain Extend existing / drain line as needed In existing wall for new waterfountaln location WATERFOUNTAIN SANITARY RISER ��xisting drain Imes 2" to remain nts to existing sewer service 'IL �T�� U m iO C] I R u s U v v' O 1L +-) �— E O � 7 +� N � U � U WE 2 �O a0 m W LnOD to O too Z ty cv v U � 4ry0 U # I`+'urrio6- W 0NC14 6' ro U — O r-1 ) �Q tr LLL E L v �4-; so L W fi f Sheet OF 6. Comm # 11-20 Existing storefront Existing storefront Existing storefront FRONT ENTRANCE Existing storefront CONTRACTOR TO FILL 2 TIE BEAM AND EXISTING 1/2" GAP BETWEEN EXISTING METAL DECK WITH FIRE WOOL SAFEING to remain \ /� / to remain \ //� /to remai` Existing storefront /to remain /to remain INSULATION AND SPRAY WITH FIRE CAULKING. UL Delgn U�4I9 Bearing wall Pating - 2 Hour/ SCALE 3/1" = I'-O" I. 3 5/8" x 1 5/8" metal Studs at 24" o.c. 2. (2) layers of 5/8" thick Type "X" Drywall 4 ft Wid applied vertically or honzontall�, screw at ched - to studs and plates with I I/4 long Ty e "W" steel screws spaced 8" c.c. *Drywall must bear the UL Classification Mark 3. R-11 Batts Insulation bearing the UL Classification Mark OPTIONAL - Provide one new layer of 5/8" type "X" Drywall each side for 2 hr i /o/ 73 Provide one new latype "X" Drywall ea FLOOF, F=L,4N I � I I F I I I— I�— I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I 1 ,Each Box represents 1 one arcade machine \ I _ I 1 Each Box represents — I —I one arcade machine I _1_ I_ _j_ I— _j_ -- I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I EXISTINIG TENANT SFACE I I I I I I I I I I I I 1 —_—I I--I--H ARCADEI-- I I I I I I Existing Column I I I Provide new 6O% x 36"h to remaln _ _ tempered glass Horizontal roller window DASHED LINES I I EQUAL ARCADE EQUIPMENT I — — — — I — j _ I I I I I I I nter top. high co I I I I I I I Provide new 36"w x 36 h fixed tempered glass window SEE BATHROOM I NEW MOP I DETAILS#ON SHEETI I I I n SINK I I-- r — I -4- 5 36" high Provide new Hi/Low water fountain Base Cabinets see detail on sheet #2. s - fled d nfy below counter top a - --- to mch cri-ting Proposed — — Ytmniess steel nk Existing sink < 7 to remain 1 I MENS / �\ /> I U ------- Existing toilet to remain Existing exit - door to remain W � I ll� W, MEN - — MEN c Existing exit - door to remain TYPICAL NOTES: I. Contractor to verify ALL notes and dimensions prior to proceeding with work. 2. Contractor to STRICTLY enforce ALL OSHA Requirements. 3, ALL Lumber to be used as Beam, Rafters, etc.., to have a minimum 1,400 P.S.i, fiber stress. 4. No dissimilar metals to touch. S. ALL Concrete used for slab repair shall be 2500 PSI concrete. 6. ALL wood in contact with concrete shall be pressure treated. 7. ALL wall dimensions are nominal and not finished wall or stud dimensions. 8. ALL plumbing fixtures to be low flow. 9. New walls and Ceiling finishes shall have a flame -spread classification of not greater than 200 10New wall and ceiling finishes shall have a smoke -developed index of not greater than 450 .11, All exposed attic insulation materials Installed on attic floors shall have a critical radiant flux not less than 0.12 watt per square centimeter. Exposed foam pastic insulation materials exposed on the underside of the roof deck or on the attic walls shall comply with F.B.C. Residential Section R314 - see permit info box of code edition 12. Gypsum board material shall conform to ASTM C3�, C9, C415, C514, C630, C931 C9�0, C1002, C1047,C1177, C1178, C12-18, C1395, or C1396 and shall be installed according to the following: REMODELE WOMEN Provide new plumbing N fixtures - see plumbing plan EXISTING WALL 15 CONC BLOCK WITH 5/8" EA SIDE (2 HOUR) remain m Provide new 48'w x 36"h drywalled opening to match existing windows EXISTING TENANT FACE Existing_ window to remain ell a LOBBY/WAITING Q Provide new 48"w x 36"h v drywalled opening to match existing windows Provide new 60"w x 50"h tempered glass Horizontal v roller window a, 18"w x 64"I x 34" high counter top per F.B.C. 11-1.2 See detail on Demolition Plan ED EXISTING / WOMENS B TH C 42" high counter top 36" high counter top 42" high , counter top Provide one new layer of 5/8" type "X" Drywall for increased fire resistance. CASHIER EXISTI OFFICE Pro de one n w layer of 5/8" ty e "X" Dr wall for increased e resist nice CONTRACTOR TO REPLACE ALL BATHROOM FIXTURES WITH NEW ADA SIZED FIXTURES TO COMPLY WITH CURRENT BUILDING CODE. Dr wall y Thickness Location Orientation Framing Member Max. spacing p g of fasteners Nail sizing options For installation of dryuall into Maximum wood framing members Nads Screws 2" x min. thickness Ceiling Perpendicular 24" 1" 12" 13ga 1 3/8" lloong wth 19/64" head O 0.098" diameter x 1 1/4" long annular -ringed or 5d cooler nail /2 Walls Either16118" 6" 0,080" diaOR 1 5!8" long with Direction 15/64" head OR Ggpsum board nail 0.086" dia. x 15/8" with 9/32" head. Ceiling Perpendicular 24" 1" 12" 13ga 1 5/8" bong with 19/64" head OR 0.098" diameter x 1 3/8" long annular -ringed or dd cooler nail OR Walls Either 141, g° I6" 0.092" dia. xx 1 1/8" long with Direction 1/4" head OR Ggpsum board nail 0.0915" dia. x 1/8" with 9/0" head. Z 0 An m � ? _ U ZU <Z N_ UX OUJ XIN Existing exit door to remain THERE IS NO MECHANCIAL WORK TO BE DONE. EXISTING SHALL REMAIN AS -IS. SITE ADDRESS: _110 S. US HIGHWAY I, PORT ST, LUCIE, FL. COPYSquare Footage Calculation �,5 UR ATTACHMENTS i JNSIBWTYOFTHE 4:,INACTOR OF RECORD THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORREC11ONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY MT N AIL ANPI41MIll I 1111100 SCALE 1/4" = 1'-0" ST. LUCIE COUNTY PLAN REVIEW ELEC: DATE: DATE: DATE: 2 MECH: DATE: 13. Insulation including facings such as retarders or vapor permeable members installed within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics shall have a flame spread index not to exceed 25 with an accompanying smoke developed index not to exceed 450 when tested in accordance with ASTM E 84. Insulation shall comply with F.B.C. Ral6. Net Square footage = 1,0-11 Sq. ft. Total of Bathrooms Partitions etc... = 1,120 Sq. ft. Total Square Footage = 3,017 sq. ft. OCCUPANT LOAD 3,011 sq. ft. (gross) / II sq. ft. per person = 214 persons (A-3 Assembly gaming) Including cashier and existing office spaces FERMIT INFORMATION THIS PROJECT HAS BEEN DESIGNED AND SHALL ADHERE TO THE 2001 EDITION OF THE FLORIDA BUILDING CODE WITH THE 2009 SUPPLEMENTS AS WELL AS THE CURRENT VERSION OF THE FLORIDA FIRE PREVENTION CODE. FOR WIND DESIGN, THIS PROJECT HAS BEEN DESIGNED AND SHALL ADHERE TO ASCE 1-05 WHERE EXTERIOR WORK IS SHOWN ON THESE PLANS. ELECTRICAL SHALL COMPLY WITH THE 2008 EDITION OF THE N.E.C. THE OCCUPANCY TYPE SHALL BE: A-3 ASSEMBLY THE CONSTRUCTION TYPE I5: TYPE II B THIS BUILDING IS NOT SPRINKLERED THE EXISTING ROOF STRUCTURE IS AS FOLLOWS = LIGHT -FRAME TRUSS TYPE CONSTRUCTION - ROOF ONLY SITE ADDRESSES SHALL BE PLACED CONSPICUOUSLY ON THE FRONT OF THE STRUCTURE, SO THE NUMBERS CAN BE SEEN PLAINLY FROM THE STREET NUMBERS SHALL NOT BE LE55 THAN SIX INCHES IN HEIGHT MINIMUM WALL t CEILING FINISHES PER F.B.C. TABLE 803.5 GROUP: A-3 NON-SPRINKLERED Exit Enclosures t Passageways: _A Corridors: A Rooms t Enclosed Spaces: C - o� �0 gyp/ 0 1° 0 U U nW LL 4 -) EAO o o U E Lu U 4-) a� � � U J U BOOM �C�I�DU�� room floor base walls ceiling clg. height Arcade Carpet VCT drywall Existing Acoustical Existing 5 10'-O" Lounge Carpet VCT drywall Existing Acoustical Existing 5 10'-0" Cashier Carpet VCT drywall Existing Acoustical Existing e 10'-0" Office Carpet VCT drywall Existing Acoustical Existing 9 10'-0" Bathrooms VCT VCT drywall Existing Drywall Existing 5 8'-0" Janitors Closet VCT VCT drywall Existing Drywall Existing a 8'-0" COotes:, I. ALL trim to be high gloss White � F, FILE '1 2. Allow for 3 different Interior paint colors 3. Faint to be Benjamin I'loore or equal. UJalls to have 3 coats. �I. VCT Base to match existing - repair existing where needed. S. Car et Allowance: $IS.00 per yard Installed 6. \/CTAllowance. $10.00 per yard Installed 7. Owner to specify carpet tl� colors prior to construction O 4'tn Q cQ Q0mNo Q a) v i n cn ,0 0 C CNN uU fa �'0D40 oQ III N O C-4 L .4.1 U i r- a3 6- aui orr� -tt+ rr— x toJ �V ru ELL Q IL 7 L CQ Sheet St. OF 6. O`' Comm # II-20 ie County &V = New Studs at 16" 0-c ( see typlcal section ) Contractor to verify all existing life safety Swap out exiting exit light devices are in good working order. If found with new fixture which shall to be defective, contractor to replace with new. Include emergency battery backup lights \ ENIITRY DOOR vA11-05 Provide if none currently exists. Field verify prior to ordering —I E d Existing exit light to remain I P m Electric Power pole dropped from ceding Swap out existing exit light 1 1 O with one duplex receptacle for gaming with new fixture which shall I I �- — ( machines — — I f— Include emergency battery backup i up light 9 II I I I I I I I I NEW OUTLETS SHOWN III ARE IN ADDITION TO I I EXISTING TO REMAIN I 1 I NEW OUTLETS SHOWN I 1 I I I III EARE IN XISTING ADDITION TREMAIN I 111 ( I 1 II I 1 11 I I I I ill I II I I I( I I li I I I—/f--I \Ito new circuit I // I .I - EXIS7INr4/ �EI� ANT SFAC,E I I I in panel "B" emove., existing rec9�tacles 1 `. for new door opening- �` AgCADE I_ 1 I I l I I I to new circuit I I I 1 I ' I I I I I I in panel "ID"I I I to new circulfl D D in panel "0" 1 — _ I to new circuitl _ — to new circultl- - I 1n panel "B" � In .panel "C" I I I I I I I column to I I I — J I — I — remain Electric Popwer le droppped from telling DASHED LINES -{�� I I with one dhplexfr�ceptadle for gaming EQUAL ARCADE 1 1 I machines. I I l EQUIPMENT- -� I \ \ I II NEW OUTLETS SHOWN II EXISTINGARE IN TO ADDITION RTO EMAIN- 4 I—t-1-7 1 T1 to new circuit I I I 1 III I I III I ' B" 1 in panel Relocate existing — i — thermostat in new — �E wall \ \ NEW EXIT v �1to new circuit tl x A x LIGHTS, n panel "C" to new circuit (°\ Relocate existing in panel "D"------- E T electric to new wall location O] O4EXISTING IEMENS NEW EXITLIGHTSr\UJOMEN to new circuJ n panel "D"MENSI� E WOMEN�U-ZZ -i Existing exit light to remain Et existing exlt light F Contractor to verify all existing life safety with new fixture which shall devices are in good working order. If found include emergency battery EXISTING to be defective• contractor to replace with new. backup lights PANEL "B" ELECTRIC;HL FLAN Swap out existing a light with new fixture whiff %Shall Include emergency be Lary backup fights. Provide new TV ,lack EXISTING € 2 TENANT SFACE �rovide new TV jack LOBBY/WAITING Remove existing outlets ©from removed.. wall- T _ I,r ii1,1 u It 1I I 11 II I-- xLl j IU. IL i 11 vll a--_ ILJJL JL JL jz'XISTING WOMEN BATHROO O NEL "0" ONE NEW CIRCUIT TO ONE NEW CIRCUIT TO ONE NEW CIRCUIT TO BE ADDED TO PANEL "B" BE ADDED TO PANEL "C" BE ADDED TO PANEL "D" ELECTRIC NOTES: SCALE: 1/4" 1. Use copper wire only, no aluminum. 2. Contractor to verify location of electrical service and provider 3. ALL Branch Circuits that supply 125v single phase 15 amp or 20 amp outlets shall be protected by an Arc —Fault Circuit Breaker 4. New receptacles shall be Tamper resistant AFCI. 5. ALL receptacles located In bathrooms or within IOft. of sinks to be GFI protected. �. ALL EXISTING BATHROOMS HAVE EXHAUST FANS. CONTRACTOR TO VERIFY THEY ARE ALL IN PROPER WORKING ORDER AND SHALL BE REPLACED IF FOUND. OTHERWISE, 8. Contractor to repair/replace any existing panel, electrical device, !ght fixture etc... with any defect. THERE IS NO MECHANICAL WORK TO BE DONE. EXISTING SHALL REMAIN AS -IS. KB - = Fire Department Knox Box = Fire E/tingui-) &r mounted �O'" A.F.F. Extinguishers to be ABC - UL ::AIOBC SITE ADDRESSES SHALL BE PLACED CONSPICUOUSLY ON THE FRONT OF THE STRUCTURE, SO THE NUMBERS CAN BE SEEN PLAINLY FROM THE STREET NUMBERS SHALL NOT BE LESS THAN SIX INCHES IN HEIGHT ,e existing circuits from removed is in new walls CASHIER Provide' new x1�t light 'nE) Fl`l EXISTI OFFIC,4 Provide new TV jack ,Reuse existing circuits .from removed outlets in new walls Provide new TV jack Relocate existing TV jack Existing battery backup linht to remain EXISTING -` EXISTING '-- SUB -PANEL PANEL "E" Swap out existing exit light with new fixture which shall include emergency battery backup lights ONE NEW CIRCUIT TO BE ADDED TO PANEL "E" FOR NEW LIGHTING - SEE SHEET R1 ELECTRICAL SCOPE OF WORK: — CONTRACTOR TO RELOCATE EXISTING OUTLETS AS SHOWN DUE TO NEW PARTITION LOCATIONS. — CONTRACTOR TO PROVIDE NEW TV JACK LOCATIONS IN LOUNGE �a+ FIELD VERIFY EXACT LOCATIONS WITH OWNER AND EXISTING RECEPTACLE LOCATIONS. — REPLACE EXISTING EXIT LIGHTS WITH NEW EMERGENCY BATTERY BACKUP LIGHT/EXIT LIGHT COMBO PACKS AS SHOWN. EXISTING ELECTRIC NOT SHOWN BUT IS SUFFICIENT FOR NEW USE AS IS. 11 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO 901110W WAIN A6 AIN111110AM 01,11111111111111 PANEL "B" Poles BR Load Wve Dascnpton circtl crctl Description We Load BR I Poles 2 40 4.1 kw a8 2 Ton A/C comp 1 2 AHU al0 2.3 km 30 2 3 4 2 30 4.5 kw a10 40 gal, water HTR 5 6 Exhaust Fan 412 .8 kw 20 1 1 a Ughtng all 20 1 20 912 Recets 9 10 Eest I Emergency a12 20 1 1 20 #12 Recets 11 12 Now Reeepts 612 — 20 1 I 20 all Bathroom GPI 13 14 Nw Receipts 812 — 20 I $ pare Is IL Noes Rocal 812 — 20 1 s are n 19 s are s are 19 20 S are s are 21 22 s are s'8re 23 24 spare s are 25 26 s are s are 21 29 s are s are 29 30 'Dare s are 31 32 s are PANEL "Bo LOAD CALCULATION SHEET Load Description Otti. Watts Total(Watts) General Lighting (3 watpk aq., ft.) Including new, .... . , , Exleting Exhaupt fan, . , , , , , , Exlatmg . Water. ,Neater 133 3 2,199 I 1,200 800 1 4,500 4.500 Total Watts 1,499 First 10000 Watts e100% 1.499 1.499 Remainder O 040% O O Electric Heat or A/C 965% 10,000 (.,Soo Calculated Load Watts 13.999 Voltage 240 Calculated Wattage Divided by Voltage = Total Amps 58.32 IOOA Panel exists Panel Sim Required = 100 Amps PANEL "D" Pd•s BR Load Wire _ Description circ4 nrcA Descmption We* Load BR Poles 2 40 4.1 kw tle 2 To A/C coma 1 2 AHU 410 2.3 km 90 2 3 4 2 30 4s kw al0 40 gel. water HTR 5 6 Exhaust Fan a12 .8 kw 20 I 1 8 Lighting 412 20 I 20 a12 Recets 9 to Emet I Emergency all 20 1 20 412 Recets 11 12 Now Rewpto 812 — 20 1 20 $12 Bathroom GPI 13 14 Nw Rec pts 812 — 20 '1' 9 afe is 16 Now Racepts 20 1 9 are 11 Is Nes Water Pearson 212 20 1 S are 14 20 9 Are s are 21 22 spare spar 23 24 spare s are 2s 26 so -are at s wire 21 28 9 are 5 are 29 30 s are s are 31 32 s are PANEL "D" LOAD CALCULATION SHEET Load Description 0 tii. Watts Total(Watts) General LghtfN (3,watts aqft.),Including new.,,., .... ExistingExheustfan,,,,,,. _,..,_.. ...... ... ......1 Exiatmg Water, Heater New .,Water .fountain.. ...... 133 3 2.199 1200 800 1 4500 4500 1 BOO Soo Total Watts 8,299 First 10000 Watts e100% 8,299 8,299 Remainder O e40% O O Electric Heat or A/C e65% IO,000 4,500 Calculated Load Watts 14199 Voltage 240 Calculated Wattage Divided by Voltage = Total Amps 61.L6 IOOA "anal exists Panel Size Required = 100 Amps FILECOPY Electrical S mbol Legend S single Pole snatch ® Recessed -Can Light Double Pde switch ® Eyeball Recessed Can Light Dinner Switch Exhaust Fan m� Push Button Switch ¢ Canting Mounted Light Duplex Outlet 0- Wan Mounted Light Special Recaptade W Light with Pill Chain (attic) _Ilk Weterprod, ground fault nitarmptal © Computer Connection Jack ® Floor Duplex Outlet 4C? Flood Light Q Junction Box m I Electrical Panel T Thermostat rc::f, Electrical Meter Central Vac oocac A/C Disconnect ® smoke Detector Fen ®Ceiling Televiaon Jack t Telephone Jack ® 2 x 4 Florescent Light ® I x 4 Florescent Light © Intercom afoul Spar Hook-U O Ceiling Mounted Light Dome Style Pendent Light ® Motion Detector I closat light ) © Carbon Monoiado Detector (2) Quad-plax outlets PANEL "C11 Pales BR Load Wira Descnpuon circa circtl Description Wire Load SR Pen 2 40 4.1 kw a9 2 Tom A/Ccomp 1 2 AHU a10 2.3 kw 30 2 3 4 2 30 4.5 kw 910 140 gal, water HTR 5 6 Exhaust Fen a12 .8 kw 20 1 1 8 Lighting 012 — 20 1 1 20 e12 Bathroom GFI 9 10 Exist I Emergency all 20 1 s are II 12 NowR•wpt• 812 20 I s 8re 13 14 Nw Rewpts 912 20 1 s are Is 16 arjare s are IT 19 s are s are 19 20 s are 5 8fe 21 22 9 are s 8re 29 24 s are s are 25 26 spare s are 21 28 spare spare 29 30 s ere _ 5 are 31 32 s are PANEL "LOAD CALCULATION SHEET Description Qt . Watts Total(Watts) General,L( hpn . (3 watts sq..ft,> Includm new g 9 g Existing Exhaust ,fan Existing Water Heater, _ .. , . . . , , , . 133 3 2,199 1 1.200 800 1 4.500 4.500 Total Watts 1,499 First 10000 Watts 9100% 1,499 1.999 Remainder O e40% O O Electric Heat or A/C 945% 10,000 6,500 Calculated Load Watts 13.999 Voltage 240 Calculated Wattage Divided by Voltage = Total Amps 58.32 IOOA Panel esests Panel Size Required = 100 Amps PANEL "E" Pen Bit Lead was Description circtl cuts Description Wire Load BR Poo 2 40 4.1 kW 49 2 Ton A/C comp 1 2 AHU 410 2.3 kw 30 2 3 4 2 30 4.5 ku clo 40 gal. water HTR 5 6 Exhaust Fan B12 .9 kw 20 I 1 a Lighting 912 20 I 1 20 212 Facets 9 10 Emat I Emergency 012 20 I 1 20 412 Recets 11 12 NEW LIGHTING 812 20 1 1 20 — 112 Bathroom GPI 13 14 spare Spare is 16 spare 8 are 11 18 s Are spare 19 20 9 Are Stpare 21 22 s are Spare 23 24 slDare s are 25 26 s are spare 21 28 stare SIDare 29 30 s are 5 are 31 32 s are PANEL "E" LOAD CALCULATION SHEET Load Description (2tif. Watts Total(Watts) General Lighting; ,(3, wattp..aq. ft.) ,Includmp .new .Extetmg Exhpust fan .... ......... .......... ....... Esusting Water. Heater,. .... ... ... ..... .. _ .. . 133 3 2,199 1 1200 Soo 1 4,500 4500 Total Watts 1,4419 First 10000 Watts 9100% Remainder Q 940% Electric Heat or A/C 845% Calculated Load !Volta ne240 Calculated Wattage Divided by Voltage = Total Amps2IOOA Panel exists Panes T ffl r . U a0 T Q LL. U 0) 1-1— _ O U U' CV 7 11I U m J_J-a U 7 J UN 0 (tl C d) aD C(1 w 4 v Ln OD too � (`l (`I U r: r- r^C OQ >rr- UQ a 00 OD � tt CNN ra N 0NNCr L 4J U r r- i6 Cr a41i o r- f- m L - '7 tXo E U_ Q i- lL I W` N L 11f Sheet LIn& Man SCALE 1/4" = I'-O" PLUMBING FIXTURE CALCULATION: Total Otcupant Load = 271 persons/2 = 136 persons per sex. Per FBC P4C3.1: Water Closets: Lavatories: Drinkl�__�oun_t-sin Servl�� sink: REQUIRED 11AL_F_ _I per 200persons - I per 500 persons I Reaulred PROVIDED 2 3 2 .I _3 hi/low fountain I provided Exlstln 2" V TR Extend existing I JIL vent for new smk location \ J 12„ I2 IEAV-1g. .. Existing dram fines Extend existing to remain drain line as noticed for new Sink location Existing WC -I 3" Ganneee w JANITORS SINK SANITARY RISER PLUMBINCG SCOPE OF WORK: CONt = —TOR TO EXTEND EXISTING DRAIN AND WATER LINES AS NEEDED FOR NEW TOILET LOCATIONS - CONTRACTOR TO EXTEND EXISTING SINK ®RAIN AND COLD WATER LINE AS NEEDtQ FOR NEUJ WATERFOUNTAIN INSTALLATION - CON-rR ACTOR TO CAP EXISTING WATER $ pRAIN LINES AT NEW STORAGE ROOM WHERE EXISTING BATHROOM FIXTURES ARE TO BE REMOVED, FIXOT0r-,a TOIN ALLOBATH OOMS WHERELACE ALL I EX�STING ARE NCN COMPL ANG FIXTJRES WITH NEW DT. APPROVED nts Extend existing J'L vent for new toilet 1 location 1I �XIStIN oseQ y Iv. Extend existing drain line as needed I p for new toilet location J Existing WC -I To be _.. .....-Removed_ cackfiow Preventor wets iter line 1 for new ftaon tew shut off valve %let location — 7 Remove existing tolet e� water line as needed TOILET TYPICAL TOILET ROOM WATER LINE EXTENSION Dashed Imes represent existing hot water piping I@jI P Cap ti exisng 'J hot water line rl as naeda l.'n/ I Existingwater line✓ re- �o remain/\�//�/ / FNQ G HOT WATER R TO REMAIN CURRENTLYTHE JANITORST Emoting water line to existing oink removed. Contractor to provide —backflou Preventor it none exists. Field verdg. ,Contractor to add shut air valve it none exists. Field verify. connect new water fountain to existing sink cold water tine WATER FOUNTAIN WATER LINE WORK Provide new water hammer arrestor Emoo" Provide backflow Prevents' o-ZAV to me..Provide new shut off velva at new Sink location NEW JANITORS SINK JANITORS SINK Exatln WATER LINE EXTENSION WC to remain UJat&r L&g&r Cold Water Piping Water Hammer Arrestor — — — Hot Water Su I (I10°) Pp y Temppering and Pressure relief Valve Conformin with ASTM Z21.22 Flow Direction Cold E Hot water Cold Water Pipe Size — _ -0111u- Watts RP2-919 BackFlow Preventor Hot Water Pipe size _64— Check Valve -I Typical water shut OFF valve -4-I— Ball Valve NOTES: - ALL Water pipe to be "L" Copper Pipe - Store all hot water at 140°F in water heater - Temperature limiting device which shall conform to ASSE 10-10 with a max. max. temperature of 110° per F.B.C.P. 6CTI - Verify all existing pipe diameters (where applicable) prior to ordering valves. be - ALL through wall vents Shall terminate IOft. above average ground level and shall protected from birds and rodents entering Dr blocking vent openings per FBC P 904,6 Existing drain lines to remain TYPICAL BATHROOM to existing SANITARY RISER sewer service nts Provide new 2' vent lines and connect to existing vent EXISProposed I \ 2x VTR Sink r \1L Connect new sink tLFAV tdrwn to ewetrng wet-:ISf XU dram in@6 talet line WC -I olremain Uncap existing toilet dram and pprovide now tolet Remove existing fixture Sink Drain and vent Imes. to existing REMODELED WOMENS sewer service BATHROOM,: RISER tits EXISTING 2' VTR A Extend existing drain line as needed For new sink location 1 EXIST EXIST 1 WC -I LAV-I E xietmg drain lines ew°,°1Ae�, etyµ,e,e to remain swsr"Rw EXISTING WOMENS BATH SANITARY RISER fits �I a-� N ai 7 t7 N � a-s L C OJ E 7I E O oO U� uI � C Qt O i ...r O r_ V to -a Q7 to00 I — O O I N N I I tr Ln to—_ oir�� T U� C) Q Exlsting 2" VTR JiL i Remove Existing sink la/ drain lines as needed " l.r i existing vent to remain Extend existing / 2 toremainsting fines drain line as needed In existing wall for new waterfountam location to existing WATERFOUNTAINsewer service SANITARY RISER THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY 9E NECESSARY IN ORDER TO QOMP41► MTN A6.AF_FWWM $Oft nts U _.1 0) O IL E o o U L CV E LU u 4 a) U ULID n�n (L ctl .-r O X Y �o tn m cn N O t_ QI W L n UD f6 O `` 7ciN U ��� oa (- Q 00 OD # CNNto 7 I I N O CA CA +-f vrr ao U Of r�q erd L __1 t- (U E '7' U ~ IL Q fu � g Sanitary line BT 1 Bath Tub "P" trap — — — Vent Line 1.1 SH-I Shower "P" trap riAv-I Lavatory Trap rM-I Washing Machine Drain F, I Sink Trap r Urinal W I_I Water Closet rF-I Water Fountain Drain FDI-I Floor Drain GP Grinder Pump C.O.ent Clean Out �L2' VTR 2" Vthru Roof 2 Jw - 2" Vent thru wall 2" Pipe Dlameter Designation (2" dia) NOTES: - ALL sanitary pipe to be Schedule 40 PVC - Slope hall be no less than 1/8" per foot and no more than 1/4" per foot v Sheet Comm # 1-20 '�tx. Existing storefront to remain \ Existing storefront to remain x Existing storefront to remain Existing storefront 'to remain \ FRONT ENTRANCE Existing storefront to remain UL Design U334� Bearing wall Rating - 2 Hou SCALE Vf = I' - I. 2" X 6" Studs at 16" o.c. cross braced at mid -height and fire stopped at top and bot m of wall 2. Resilient, 25 MSG gals, steel, nom 2 1//channels: x 1/2" deep. Furring channels placed perpendicular to studs, spaced vert. max. flange portion attached to each intersec with I" long Type S steel screws 3. 6/8" thick, 4 ft. wide attached to furri base lagger with I" long Type S steel scr max. 29" o.c., Face layer with 1 5/8" long Type S steel screws spaced max 12" o.c. Attached to wood studs: base layer with 1 1/8" long 6d coated nails spaced max. 14" o.c.. Face lager:with 2 3/8" Ion long 8d coated nails spaced max I" o.c. Base layer shall be installed vertically and face layer shall be installed horizontally with butt joints offset 16" fr m base layers. 4. R-II Batts Insulation bearing the UL classifi Lion mark friction fit between studs. S. Vinyl, dry or premixed point compound a lied to joints, screw heads, and nail heads; Paper tape 2" wide, embedded in first layer of compound er all joints. Provide one new layer of 5/8" type "X" Drywall each side for 2 fir F_ z Z 1V < [L z UX OW Provide one new layer df 5/8"' type "X" Drywall each side for 2 hr wall FLOOR FLAN 1 c+l I F-I -F-I F-F-I ~- I I I I I I I I I I 1 I_ J I_J_J 1 - I I I I I I I I I I 1 1 -Each Box represents 1 one arcade machine \ I - I Each Sox represents � - I 1 1 one arcade machine 1 -i I I I I I I I I I J - I I I I I I I I I 1 I I I I I I I I I -1_1 1-___I I --I --I I--I---1 -- 1 1 I I I I I 1 I I I 1 I I I I I 1 I I 1 1 1 1 I EXiSTINiG TENANT SPACE I I 1 I-- --1 1 1 I I I I 1 I I 1 I I I I I I I 1 I I 1 --I 1--I--I ARCADE1-- I I I I I I I Existing Column 1 I 1 Provide new 60"w x 36"h to remain _ _ tempered glass Horizontal roller window 1 DASHED LINESEQUAL 1 EQUIPMENT 1 I I I I I 1 I I counter top. high co I I I I I I I 1 I I I 1 1 1 1 1 1 1 1 1 Provide new 36"w x 36 h fixed tempered glass window SEE BATHROOM 1 1 I DETAILS ON SHEETI 1 I l I 1 m I I_ I-- 42 _ I �r 5'-4" 5'-l" 36" high Provide new Hi/Low water fountain field verif Base Cabinets see detail on sheet tt2. x x g below counter top a to match existing CC leeu .reel I - - - ---- Ste Existing sink smk to remain o EXISTING , - MENS J Etoilet to remain Existing exitdoor to remain C i. -- o. a W MEN MEN Existing exit door to remain TYPICAL NOTES: 1. Contractor to verify ALL notes and dimensions prior to proceeding with work. 2. Contractor to STRICTLY enforce ALL OSHA Requirements. 3. ALL Lumber to be used as Beam, Rafters, etc... to have a minimum 1,400 P.S.I. fiber stress. '{. No dissimilar metals to touch. 5. ALL Concrete used for slab repair shall be 2500 PSI concrete. 6. ALL wood in contact with concrete shall be pressure treated. 1. ALL wall dimensions are nominal and not finished wall or stud dimensions. 8. ALL plumbing fixtures to be low flow. 9. New Walls and Ceiling finishes shall have a flame -spread classification of not greater than 200 10. New Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 11. All exposed attic insulation materials installed on attic floors shall have a critical radiant flux not less than 0,12 watt per square centimeter. Exposed foam plastic Insulation materials exposed on the underside of the roof deck or on the attic walls shall comply with F.B.C. Residential Section R314 - see permit Info box of code edition 12, Gyypsum board material shall conform to ASTM C36, Cq, C4�15, C51�1, C630, C931 C9b0, C1002, C1041,C1177, C1118, C1218, C1395, or C1396 and shall be installed according to the following: REMODELE II WOMEN Provide new plumbing fixtures - see plumbing plan EXISTING WOMENS B 0 EXISTING WALL IS CONC BLOCK WITH 5/8" EA SIDE 12 HOUR) window Provide new 48"w x 36"O,� drywalled opening to match existing windows EXISTING TENANT SPACE Existing window to remain LOBBY/WAITING H Provide new 48"w x 36"h drgwalled opening to match existing windows ProN sink. Provide new 60"w x 501111 tempered glass Horizontal roller window 18"w x 64"I x 34" high counter top per F.B.C. II-1.2 See detail on Demolition Plan \ 12'- 42" high counter top 3(" high counter top 42" high counter Provide one new layer of 5/8" type "X" Drywall for increased fire resistance. CASHIER new janitors re plumbing plan EXISTI OFFIO ae one "x. D CONTRACTOR TO REPLACE ALL BATHROOM FIXTURES WITH NEW ADA SIZED FIXTURES TO COMPLY WITH CURRENT BUILDING CODE. Dr wall Thickness Location Orientation Framing Member Max, s acin of fasteners Nail sizing options for drgwall Spacing Maximum installation of into wood framing members Nails Screws 2" x min. thickness Ceiling Perpendicular 24" -1" 12" 13ga 1 3/8" Icng with 19/64" head 0.098" diameter x 1 1/4" long annular -ringed or 5d cooler nail /2 Walls Either 161,8"161, 0.080" dia. 1 5/8" long with Direction 15/64" head OR Ggpsum board sail 0.084" dia. x 15/8" with 9/32" head. Ceiling Perpendicular 24" 7 12" 13ga 1 5/8" laig with 19/64" head 0.098" diameter x 1 3/8" long e annular -ringed or 6d cooler nail OF Walls Either 161,all 141,0.092" dia. x 1 1/8" long with Direction 1/4" head OR Gypsum board nail 0.0915" dia. x 11/8" with 19/64" head. THESE ARE St hfAY BE I 00Mf6Y layer of 5/8" for increased Existing exit door to remain THERE iS NO MECHANCIAL WORK TO BE DONE. EXiSTING SHALL REMAIN AS-iS. SITE ADDRESS: _110 S. US HIGHWAY I, PORT ST. LUCIE, FL. ILE COPY LED FASTENERS OR ATTACHMENTS THE RESPONSIBILITY OF THE CONTRACTOR OF 11100111) NS AND ALL PROPOSED WORK CT TO ANY CORRECTIONS BY FIa INSPECTORS THAT CESSARY IN ORDER TO FiAcZi. 2 uie arki 89A• bcil 13017 El SCALE 1/4" = 1'-0' SL LUCIE COUNTY PLAN REVIEW R ELEC: DATE: PLUME DATE: MECH: DATE: 13. Insulation including facings such as retarders or vapor permeable members installed within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics shall have a flame spread index not to exceed 25 with an accompanyin smoke developed index not to exceed 450 when tested in accordance with ASTM E 84. Insulation shall comply with F.B.C. R316. Square Footage Calculation Net Square footage = 1,891 sq. ft. Total of Bathrooms Partitions etc... = 1,120 sq. ft. Total Square Footage = 3,011 sq. ft. OCCUPANT LOAD 3,01"1 sq. ft. (gross) / II sq. ft. per person = 214 persons (A-3 Assemblg gaming) Including cashier and existing office spaces PERMIT INFORMATION THIS PROJECT HAS BEEN DESIGNED AND SHALL ADHERE TO THE EDITION OF THE FLORIDA BUILDING CODE WITH THE 2009 SUPPLEME AS WELL AS THE CURRENT VERSION OF THE FLORIDA FIRE PREVENTION CODE. FOR WIND DESIGN, THIS PROJECT HAS BEEN DESIGNED AND SHALL ADHERE TO ASCE 1-05 WHERE EXTERIOR WORK IS SHOWN ON THESE PLANS. ELECTRICAL SHALL COMPLY WITH THE 2008 EDITION OF THE N.E.C. THE OCCUPANCY TYPE SHALL BE: A-3 ASSEMBLY THE CONSTRUCTION TYPE IS: TYPE II B THIS BUILDING 15 NOT SPRINKLERED THE EXISTING ROOF STRUCTURE IS AS FOLLOWS °= LIGHT -FRAME TRUSS TYPE CONSTRUCTION - ROOF ONLY SITE ADDRESSES SHALL BE PLACED CONSPICUOUSLY ON THE FRONT OF THE STRUCTURE, SO THE NUMBERS CAN BE SEEN PLAINLY FROM THE STREET NUMBERS SHALL NOT BE LESS THAN SIX INCHES IN HEIGHT MINIMUM WALL t CEILING FINISHES PER F.B.C. TABLE 803.5 GROU -3 N N-SP IN L RED Exit Enclosures t Passageways: A Corridors: A Rooms t Enclosed Spaces: C a MIN, SETBACK REQ. FRONT SIDES CNR SID i�00M SC�I�DU�� room floor base walls ceiling clg. height Arcade Carpet VCT dr wall Existing Acoustical Existing 0 10'-0" Lounge Carpet VCT drywall Existing Acoustical Existing fl 10'-0" Cashier Carpet VCT dr wall Existing Acoustical Existing 9 10'-0" Office Carpet VCT dr wall Existing Acoustical Existing 9 10'-0" Bathrooms I VCT VCT drywall Existing Drgwall Existing a 8'-O" Janitors Closet VCT VCT drywall Existing Dr wall Existing 0 8'-0" Notes: i. ALL trim to be high gloss white 2. Allow for 3 different interior paint colors 3. Paint to be Benjamin Moore or equal. Walls to 4. VCT Base to match existing - repair existing 5. Car�pp�et Allowance: $15.00 per yard installed �. VCTAllowance: $10.00 per and Installed 1. Owner to specify carpet tl�e colors prior to have 3 coats. where needed. construction CZ D15'C� i�ylr►r'�o_Ss 435Y � s�E� N I O N N N 0 i 3 0 0 1 119 6o u U L. (1 LL- Q) E _ `o U lL O E IU U 4 a� U J � U fL X Y 4� oD bo 1) v to aD N =CA C 00 00 ki E I I O �'. d 00 00 to CN(40 L+)urr 0 m � orr� ,,U` t! in mE d ~LL I W Sheet l . OF 6. Comm # 11-20 X X c ORIFICE HEIGHTSm ry t+l Floor Demolltlon Flan 11 — 19" MMMin.in, WALL Water Fountain Spout Height and Knee Clearance Detail NTS 48" Min Water Fountain Clear Floor Space Detail NTS Water Fountain Notes: — Water Fountain spout shall provide a flow of water at least 4 inches high so as to allow the insertion of a cup or glass under the flow of water. On an accessible drinking fountain with a round or oval bowl, the spout mumt be positioned so the flow of water is within 3" of the front edge of the fountain per F.B.C. II-4.15. — Fountain shall comply with F.B.C. P410 as shown on floor plan. SCALE 1/4" = I'-O" Provide new Elkay EZSTL8C 4/Low Water cool ier. Existing ceiling to remain-- X Provide new 60"w x 50"h tempered glass Horizontal roller window , ACCESSIBLE COUNTER DETAIL 1/2" = 1'-0" THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH Ark APPWQAM 1116DES. Existing in ulati n existA structur Existing Suspended acoustical ceiling 4 R-ll batts insulation between bathrooms t hallways. O 1 L 2"x4" wood blocking to be us L — metal fire block elsewhere I � W N 0 X (!) W Q 5/8" drywall on 1 5/8" x 2 22 ga. metal studs existing slab base to match existing I units and at ed for grab bars 5/8" Typical Interior non —bearing wall Detail NTS 54" min. Grab Bar 34" A.F.F. Grab Bar 34" A.F.F. li9 A.F.F _ MIN. L I 6O" Min. \ o l°rirro>r 5'-0" Typical AcceSSlble Bathroom Detall 1/2" = I'—O" Tuplcal Bathroom Notes: I. Toilet paper Holder = American Specialties model # 0263-1A contractor to provide blocking so holder is 19" A.F.F. 2. Mirror = American Specialties Model # 0535-1830 fixed angle tilted mirror ( 18" x 30") insert size code = A Contractor to provide blocking so mirror will be 40" A.F.F. ( max.) 3. 36"long grab bar = American Specialties Model 43800 using type OI configuration as shown in details. 4. 42"long grab bar = American Specialties Model #3800 using type 02 configuration as shown in details. S. Walls within 2 feet of urinals and water closets shall have a smooth, hard, nonabsorbent surface, to a height of 4 feet above the floor and except for structural elements, the materials used in such walls shall be of a type that is not adversely affected by moisture. 6. THIS MATERIAL SHALL BE F.R.P. BOARLD AND SHALL BE ON THE PLUMBING WALL AND THE WALL TO THE RIGHT OF THE TOILET AS YOU WOULD FACE IF SITTING ON THE TOILET. 11 O 0 nf// a�moUmQ I � U s l� 1° O U A W a- L U ff) U 7 J RN •' V c0 oom G) 0 M OD NO ra O W QOM EOQ � 00M Ql Cl Cl ## � I +� err orr�V 03 U ' �� cn m E d LL Ul L T V L � If Sheet 2, OF L. Comm # 11-20 Sdrltaru Llre Fldr PLUMBING FIXTURE CALCULATION: Total Occupant Load = 211 persons/2 Per FBC P403.1: SCALE 1/4" = 1'-0" = 136 persons per sex. REQUIRED M LE. FEMALE Water Closets: I pler 15 I per 15 Lavatories: 1 per 200 persons Drinkino Fountain : 1 psir 500 persons Service sink: I Required PLUMBING SCOPE OF WORK: PROVIDED MALE FEMALE 2 3 2 3 I hi/low fountain 1 orovided - CONTRACTOR TO EXTEND EXISTING DRAIN AND WATER LINES AS NEEDED FOR NEW TOILET LOCATIONS - CONTRACTOR TO EXTEND EXISTING SINK DRAIN AND COLD WATER LINE AS NEEDED FOR NEW WATERFOUNTAIN INSTALLATION - CONTRACTOR TO CAP EXISTING WATER t DRAIN LINES AT NEW STORAGE ROOM WHERE EXISTING BATHROOM FIXTURES ARE TO BE REMOVED. - CONTRACTOR TO REPLACE ALL EXISTING FIXTURES WITH NEW A.D.A. APPROVED FIXTURES IN ALL BATHROOMS WHERE EXITING ARE NON -COMPLIANT. Vent for new toilet location �f XISting`II oaeQ 1 LIaV. I �I I I VI Extend existing drain line as needed h E) for new toilet location to Existing WC-1 To be Removed TYPICAL BATHROOM SANITARY RISER nts Provide new 2' vent lines and connect to emoting Vent 1 \ EXISTING' Proposed, \ Sink I r, \ Connect new mnk drum to existing mat talet line WC-1 Uncap —sting\� toilet drmn and-� provl, new toilet Remove emotng fixture Sink Drain and vent lines. REMODELED WOMENS BATHROOM RISER nts iackflau Preventur mats ter line I for new ition tow shut oft valve xlet location — FX15TING HOT WATER HEATER TO REMAIN Ime� Ewen water Ilnev AND IS CURRENTLY n8 OVER THE JANITORS to roman CLOSET Dashed hots represent i existing hot water piping Remove emating toilet �o__�watsr line as needed I_, TOILET TYPICAL TOILET ROOM WATER LINE EXTEN5ION extend hot t cold line as needed for new sink location Provide backflow Proven',, Provide new shut off valve at new Sink location — Emoting water line to existing sink removed. Contractor to provide backflow Proventcr if more Cap emotingIJ exists, Field van}g. hotwaterline rl as needod.le.i Contrxtar to add shut off valve it none exists. Field verify. connect new water fountain to existing mnk cold water line WATER FOUNTAIN WATER LINE WORK Existing motor lines to remain �4 o- Nxwm q N LAV to resmn lwsixq Jointure I. 8illk to reams JANITORS TYPICAL TOILET ROOM WATER LINE EXTENSION P-11 � y UJat&r Riser L&g&rd Cold Water Piping I Water Hammer Arrestor — — — Hot Water Supply (110°) qqTempering and Pressure relief Valve Conforming with ASTM Z21.22 Plow Direction Cold t Hot water Cold Water Pipe Size -�- Watts RP2-919 Backflow Preventor 0 Hot Water Pipe size �✓1— Check Valve H Tgpical water shut off valve Ball Valve NOTES, - ALL Water pipe to be "L" Copper Pipe - Store all hot water at 140°F in water heater - Temperature limiting device which shall conform to ABBE 1010 with a max. max. temperature of 110 per F.B.C.P. 407.1 - Verify all existing pipe diameters (where applicable) prior to ordering valves. - ALL through wall vents shall terminate IOft. above average ground level and shall be protected from birds and rodents entering or blocking vent openings per FBC P 904.6 Extend existing � ,, f vent For new Sink_�� 12" i location V i< JANITORS i \ FX15TING SINK \ 2' VTR 2i, \ \ JlL \ Extend existing 1 2" drain line as needed ' 1 for new sink location i I �C19T EXIST 1 1 LAV-I I nu l dram Imes to existing sewer service drain lines to existing sewer service Existing drain lines °�e'�YMmeetbelr... to remain .Lne EXISTING WOMENS BATH SANITARY RISER nts 2XIVTR JiL i Remove Existing sink 1a/ drain lines as needed existing vent to remain Extend existing / xirema dram fines dram Ilse as needed �o remain in existing wall For new waterfountain location WATERFOUNTAIN to existing sewer service SANITARY RISER nts THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMP4Y WITH ALL APPWp pI�QEB; Il C -� ` � fn q 0 q 02 U U LK no a-- ,c _ o U`L zi, Z E � U En U U J U WE +' V Q �O rn N a� v O 4 �m Ln co q O C �!"" vU (a�aI 1 oQ � n Q 0000 to a C'4 a- 1113 L '� lL E IL I v Sheet OF L. Comm # 1-20