HomeMy WebLinkAboutSUBMITTED DOCUMENTSF. a =ENGINEERING AND :PRODUCT DATA i D 2 LA I �A 0 y r'lok :STAR BUILDING SYSTEMS RECEIVED NOV 0 3 2004 MARK CONSTRUCTION CO. October 28, 2004 MARK CONSTRUCTION 421 GOLD MEDAL COURT LONGWOOD, FL 32750 Gentlemen: STAR BUILDING SYSTEMS P. O. Box 94910 Oklahoma City, OK 73143-491 O 405-636-2010 FAX 405-636-2419 Subject: COMMERCIAL PROPERTY ASSOCIATES FORT PIERCE, FL (A) SMT 160'-0" x 250'-0" x 20'-0" Is 10@25'-0", Bay Spacings Star Job Number 10-B-96509 (REVISED) This is to certify that materials for the subject structure have been designed in accordance with the order documents, specifically as shown per the attached Engineering Design Criteria Sheet. Aspects of code compliance as related to use or occupancy, such as sprinkler requirements, are not addressed by these documents. The materials for this building have been designed in general accordance with the 9th edition, AISC Steel Construction Manual and 1996 AISI Cold Formed Steel Design Manual with 1999 addendum. Star Building Systems is certified by AISC in Category MB. These structural components have been designed at the Oklahoma City, OK, facility and will be fabricated at one or more of the following AISC certified locations: Monticello, IA; Lockeford, CA; Elizabethton, TN; Columbus, MS; or Rocky Mount, NC. These materials, when properly erected on an adequate foundation in accordance with the erection drawings as supplied and using the components as furnished, will meet the attached loading requirements without exceeding the allowable working stress. This certification does not cover field modifications or the design of materials not furnished by Star Building Systems. The attached calculations are to remain with and form part of this Letter of Certification. This letter voids and supersedes the previous.Letter of Certification, dated September 16, 2004. The undersigned is not the engineer of record for the overall project. ordially, f, n S� AR BUILD YSTI M terials for e I Build olbertson C o oral V Dennis P. Watson, P.E. Director of Engineering Florida #17978 Ltd 8600 South Interstate 35, Oklahoma City, OK 73149 GFNhpiC o I 9i . �h'"OM'M'0• Star Building Systems Engineering Services Design Criteria Job Number: - 10-B-96509 Engineer: vJ, Building Code _ Florida 2001'--- Building End Use Commercial Classification of Building Standard Impact Loads, 'Dead Load (Star material) (Average weight of panels, purlins Collateral Loads Sprinkler - Ceiling (non -plaster) Lights Other Fixed Service Equipment Designed Roof Live Load Column Lines Ground Snow Load Wind Speed Importance Factor, Wind Wind Exposure Building Designed Internal Pressure Coefficient None ' 4.0 psf and frames) 5.0 psf (total) 0.0 psf 0.0 psf 0.0 psf 5.0 psf None 12.0 psf (Purlins) 12.0 psf (Frames) None 130.0 mph 1 B Open +/- 0.00 (GCpi) 10/28/2004 Revision 5 1 of 24 vJ "Bracing size" as noted on.Engine_ering documents and Erection drawings denotes thread diameter for rod bracing and wire strand cable diameter for wire strand cable bracing. - All bolted joints with A325 Type 1 bolts are specified as snug -tightened joints in accordance with the "Specification for Structural Joints Using ASTM A325 or A490 Bolts, June'23, 2000". Pretensioning methods, including turn -of -nut and'calibrated wrench ,are NOT required. The materials supplied by Star Building Systems are designed -for building(s) A & B to be classified as open or enclosed, per the specified building code. If all walls are enclosed in the future, the material shall attach to Star's framing to adequately transfer all loads to the main framing system (rigid frames and rodbracing). The maximum weight of any future wall enclosure material is 3 psf. Any future construction that does not leave the building classified as open or enclosed, per the specified building code, or exceeds a weight of 3 psf, could void warranties and certifications as they apply to the material supplied by Star. Product approval numbers for the State of Florida, Department of Community Affairs per Product Rule 9B-72: 1. Panel Walls FL3093.1 26 Ga'. DuraRib walls FL3093.2 29 Ga. DuraRib walls FL3093.3 26 Ga. Starmark walls FL3093.9 29 Ga. Starmark walls 3. Roofing Products FL3088.1 26 Ga. DuraRib roofs FL3088.2 29 Ga.. DuraRib roofs FL3088.3 29 Ga. Starshield roofs FL3088.9 22 Ga. Starshield roofs 7. Structural Components FL3099.1 Structural Zee Sections FL3099.2 Structural Cee Sections 10/28/2004 Revision 5 2 of 24' vi The material supplied by Star,has been designed with.the following minimum deflection criteria: The actual deflection may be less depending'= -on actual -load and -actual member length. ' The frame sidesway for wind=loading is based on a 10'year mean occurrence wind interval. Roof Purlins - - - .-Wall .Panels - Live ..t / 150 'Total` Wind L F 90 - Snow L /'150 -Wall Girts - - Wind - L / 120 Total Wind L / 90 Total Gravity_L / 150 Endwall Columns Total Uplift L / 120 Total Wind L / 120 • Frame/Portal Frame Sidesway. Roof Rafters _ .. Frame Live H�/, 90 Live L /._180 Frame Snow H / 90 Snow L / 180 Frame Wind H / _ 50 ' Wind—L' 150 -Frame Seismic H / 50 Total Gravity_L / 180 Frame Crane H'./. 0 Total Uplift_L / 150 Frame Total Wind H / 50 ' Frame Total Seismic H / 50 Roof Panels Frame Total Gravity--H / 90 Live •L / 150 Portal Total Wind / 60 Snow L_/ 150 —H Portal Total Seibmic_H / 50 Total Uplift_L / 120 All deflection and sidesway limits shown are at service loads unless indicated otherwise. 10/28/2004 Revision 5 3 of 24 vJ Star Building Systems, OKC, OK User: vjoseph Message Program - Version 2.3 Job Number: 96509A Design Summary Report run01 Date: 10/25/04 Manufacturing Plant - Elizabethton, TN Start Time: 10:17:21 J:\Active\ENGO-B-96509\OPEN02-vjoseph\Bldg-A\run01\ ,M•. A I N. B U_ I L. D ~I N G D E S I G N S U M M A R Y R E P O R T DATA .BUILDING Live Load: 12.00 psf SMT 16010 x 250 �'0' x 2Q'b., 1.:''L2 Tributary Check: YES Bays: 10@2510 Building Code: Florida 2001 Roof.'Snow Load: 0.00 psf Wind Exposure Category: B Wind Load: 130.00 mph Seismic Zone: N Dead Load: 1.90 psf Collateral Load: 5.00 psf ------------- ROOF PLANE.------- ------------------------ RPA --------- ------- PANEL : SDR 26GA GALM (DURA-RIB) PURLIN SPACING : 2@4.4044 14@510 1.1912 Bay Length Member Size Brace L Lap R Lap Bear # 1(ft) Identification Locations Exten Exten Stiff -----'---------------------------------------------------------------- 1 25.000 8.5Z88 PURLIN/ None S 0.000 3.188 C None 2' 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 3- 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 4 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 5 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 6 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 7 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 8 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 9 25.000 8.5Z72 PURLIN None - C 2.583 2.583 C None 10 25.000 8.5Z88 PURLIN None C 3.188 0.000 S None Area with Sub -Framing Bay Width Start Length Number and size of Edge Purlin # (ft-in) (ft) (ft) between Main Purlins --------------------------------------------------------------------- 1 &10 1212 0.00 8.81 1 8.5Z57 PURLIN Note(s) . 1) Area with Sub -Framing distances are measured from sidewall steel line and are additive. 2) Use 2-1/2 x 2-1/2 x 3/16 angle sub -framing for support. Purlin Anchorage Hdwe @ 9,17 @ Frame Lines:1-11 10/28/2004 Revision 5 4of24 vi Star Building Systems, OKC, OK. User: vjoseph Message Program - version 2.,3`, "' Job Number: 96509P` Design Summary Report 1 . riin0i Date: 10/25/04 Manufactuting Plant = Elizalethton, TN Start Time: 10:17:21 ' J:\Active\ENGR.-B=96509'\OPEN02-vjoseph\Bldg-A\run01\ --------------------------------------------------------- ROOF PLANE-----y,� RPC u PANEL "' :' SDR 26GA`. GALM (DURA-RIB) PURLIN SPACING 2@4.4044.14@5'0 1.1912 Bay Length-" Member Size Brace L Lap R Lap Bear _. 4. (ft)- Identification Locations Exten Exten Stiff ---------------------_------------------------------------------------ 1 25.000 .8.5Z88 PURLIN .None S 0.000 3.188 C None 2 -r 25.000 8.5Z72 PURLIN 'None C 2.583 2.583 C None - 3- 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 4 25.000 8:SZ72 PURLIN None C 2.583 2.583 C None 5 25.000." 8.5Z72 PURLIN None C 2.583 2.583 C None .6 25:000 8.5Z72 PURLIN None C 2.583 2.583 C None 7 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 8 25.000 8.5Z72 ••PURLIN None C 2.583 2.583 C None 9 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None - 10 25.060 8.5Z88 PURLIN None C 3.188 0.000 S None Area with Sub -Framing Bay Width Start Length Number and size of Edge Purlin # --------------------------------------------------------------------- (ft-in) (ft) (ft) between Main Purlins 1 &10 1212 0.00 8.81 1 8.5Z57 PURLIN Notes) . 1) Area with Sub -Framing distances are measured from sidewall steel line and are additive. 2) Use 2-1/2 x 2-1/2 x 3/16 angle sub -framing for support. Purlin Anchorage Hdwe @ 9,17 @ Frame Lines:l-il STRUTS PLANES SWA ---- STRUTS PLANES SWC ---- SIZE AND LAPS SAME AS ROOF PURLINS @ Bays 1 - 10 SIZE AND LAPS SAME AS ROOF PURLINS @ Bays 1 - 10 10/28/2004 Revision 5 5 of 24 vi Star Building Systems, OKC, OK User: vjoseph Message Program - Version 2.3 Job Number: 96509A Design Summary Report run01 Date: 10/25/04 Manufacturing Plant - Elizabethton, TN Start Time: 10:17:21 J:\Active\ENGO-B-96509\OPEN02-vjoseph\Bldg-A\run01\ ------------------------------------------------------------------------------- BRACING ---- Roof: 5 bays rods Plane SWA :Portal Frame Plane SWC :Portal Frame Plane EWB :End Frame Plane EWD :End Frame SIDEWALL PLANE SWA -- ( .8.50011 Inset columns ) "OPEN TO REMAIN OPEN" SIDEWALL PLANE SWC -- (- 8.500" Inset columns ) "OPEN TO REMAIN OPEN" ENDWALL PLANE EWB ---- Non -Expandable Frame (SMT ) "OPEN TO REMAIN OPEN" ENDWALL PLANE EWD ---- Non -Expandable Frame (SMT "OPEN TO REMAIN OPEN" FRAMES ----- Type Span Live Wind Eave Trib SMT 160.000 12.00/130.00 20.00/ 25.00 SMT 160.000 12.00/130.00 20.00/ 18.08 Frame Lines 2-10 1, 11 10/28/2004 Revision 5 6 of 24 vi Star Building Systems, OKC, OK User: vjoseph Message Program - Version 2.3-268 Job Number: 96509A Design Summary Report run01 Date: 10/25/04 Manufacturing Plant - Elizabethton, TN Start Time: 10:17:21 J:\Active\ENG®-B-96509\OPEN02-vjoseph\Bldg-A\run01\ ------------------------------------------------------------------------------- A-SWA-CF01 C A N O P Y D E S I G N S U M M A R Y R E P O R T BUILDING DATA Live Load: 12.00 psf CANOPY 1510 x 26010 x 20'0 1.:12 Tributary Check: Yes Bays: 3010 8@2510 3010 Building Code: Florida 2001 Roof Snow Load: 0.00 psf Wind Exposure Category: B Wind Load: 130.00 mph Dead Load: 3.25 psf -------------------------------------------------------------------------------- PANELS ----- Roof: SDR 26GA GALM (DURA-RIB) PURLINS ---- Spacings :316 2@419 210 Bay Length Member Size Brace L Lap R Lap Bear # (ft) Identification Locations Exten Exten Stiff --------------------------------------------------------------------- 1 30.000 8.5Z88 PURLIN None S 0.000 3.188 C None 2 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 3 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 4 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 5 25.000 8.SZ72 PURLIN None C 2.583 2.583 C None 6 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 7 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 8 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 9 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 10 30.000 8.5Z88 PURLIN None C 3.188 0.000 S None EAVE STRUTS ---- 8.5E92 E.S. @ Bays 1 - 10 RAFTER ---- Built-up BOSS Starting Ending Web Out Flange Inner Flange Length Web Depth Web Depth Thickness Width Thickness Width Thickness (feet) (inches) (inches) (inches) (in.) (in.) (in.) (in.) --------------------------------------------------------------------- 15.052 18.934 8.000 0.2500 8.00 x 0.2500 8.00 x 0.2500 With 212I Type End Connection and 8.000 x 0.625 (in) Plate. Starting Ending Web Out Flange Inner Flange Length Web Depth Web Depth Thickness Width Thickness Width Thickness (feet) (inches) (inches) (inches) (in.) (in.) (in.) (in.) --------------------------------------------------------------------- 0.708 19.643 18.934 0.1250 6.00 x 0.3750 6.00 x 0.3750 With 8.00 x 20.25 x 0.6250 (in) Boss End Plate. 10/28/2004 Revision 5 7of24 vi Star Building Systems, OKC, OK User: vjoseph Page: 6 Message Program - Version 2.3-268 Job Number: 96509A Design Summary Report run01 Date: 10/25/04 Manufacturing Plant - Elizabethton, TN Start Time: 10:17:21 J:\Active\ENG®-B-96509\OPEN02-vjoseph\Bldg-A\run01\ ------------------------------------------------------------------------------- A-SWC-CF01 C A N O P Y D E S I G N S U M M A R Y R E P 0 R T BUILDING DATA Live Load: 12.00 psf. CANOPY 1510 x 26010 x 2010 1.:12 Tributary Check: Yes Bays: 3010 8@2510 3010 Building Code: Florida 2001 Roof Snow Load: 0.00 psf Wind Exposure Category: B Wind Load: 130.00 mph Dead Load: 2.24 psf -------------------------------------------------------------------------------- PANELS ----- Roof: SDR 26GA GALM (DURA-RIB) PURLINS ---- Spacings :316 2@419 210 Bay Length Member Size Brace L Lap R Lap Bear # (ft) Identification Locations Exten Exten Stiff --------------------------------------------------------------------- 1 30.000 8.5Z88 PURLIN None S 0.000 3.188 C None 2 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 3 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 4 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 5 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 6 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 7 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 8 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 9 25.000 8.5Z72 PURLIN None C 2.583 2.583 C None 10. 30.000 8.5Z88 PURLIN None C 3.188 0.000 S None EAVE STRUTS ---- 8.5E92 E.S. @ Bays 1 - 10 RAFTER ---- Built-up BOSS Starting Ending Web Out Flange Inner Flange Length Web Depth Web Depth Thickness Width Thickness Width Thickness (feet) (inches) (inches) (inches) (in.) (in.) (in.) (in.) --------------------------------------------------------------------- 15.052 18.934 8.000 0.2500 8.00 x 0.2500 8.00 x 0.2500 With 2I2I Type End Connection and 8.000 x 0.625 (in) Plate. Starting Ending Web Out Flange Inner Flange Length Web Depth Web Depth Thickness Width Thickness Width Thickness (feet) (inches) (inches) (inches) (in.) (in.) (in.) (in.) --------------------------------------------------------------------- 0.708 19.643 18.934 0.1250 6.00 x 0.3750 6.00 x 0.3750 With 8.00 x 20.25 x 0.6250 (in) Boss End Plate. 10/28/2004 Revision 5 8 of 24 vi Strut keys x=double Z, xx=triple Z, o=pipe Builder i 3MS -11VM3QIS MARK CONSTRUCTION 0 ,06Z Job Noi 96509A run01 Version, OPEN02-vjoseph 0 ,se u,sd 0 ,52 0 ,s2ll 0 ,52 O ,S2 u,sd 0 ,SZ 0 Sd 0 ,S Date Mon Oct 25 10, 171 22 2004 2,T I I I z,T N j I I I I I I I 15S0 SJUct. 1 ' 2m 2m 2m 20 20 O rp 0 0 N � 1 O O 2 O _ O O W O 3 W O W = 0 Jo �o o o- 2m 2m 2m 20 2m 15' 0 Struct, F P 0 Note: Provide 5-7-5 screw pattern 1, 2 1' 2 with standard lap fasteners Owner MARK CONSTRUCTION 1 4 FORT PIERCE FL 34945 250'0 SIDEWALL SWA 10/28/2004 RevmSion 9 0f Star Building Systems FRAME DESCRIPTION: USER NAME:vjoseph DATE:10/25/04 TIME:11:24:04 PAGE: 1-1 8600 S. I-35, Oklahoma City, OK 73149 Smt 160./20./25. 12./130./0. JOB NAME:96509A FILE:fra2thrul0.fra DESIGN AND ESTIMATION INFORMATION FRAME ID #01 LOCATION: frame lines 2-10 STANDARD NOTES: WEIGHT: 6881 lbs DETAIL FILE: \ENG\30-B-96509\OPEN02-vjoseph\Bldg-A\Drftg\xO1L (1) All sectional dimensions are in inches. YIELD STRENGTH(ksi) - PLATE:50, PIPE:42, TUBE:46, W.F.:50, FLG BRC:50, BOLTS:A325 SNUG TIGHT (2) All Flange lengths are measured along outer flange. PURLINS(horz, from save) :8.5°-Z 204'-4 7/811,14®5' GISTS (vert. from floor):8.5"-Z (BYPASS) CONNECTION DETAILS Location 1 2 3 4 5 6 7 8 9 10 Web Dep. 8.0 34.0 N/A 30.0 25.5 25.5 25.5 40.0 6.625 6.625 Type BASE HORZ STP CAP (EXT) 3E/2E SPLICE 4E/3E SPLICE 4E/22 BASE CAP/STF Plate (DN) 8.0X0.375 3.75X0.5 8.OXO.25 8. OX0.5 N/A 6.0X0.5 N/A 6.0X0. 625 8. OXO.625 8.OXO.375 Plate(UP) N/A N/A N/A 6.OXO.5 N/A 6.0X0.5 N/A 6.OXO. 625 N/A N/A ��QQ (4)-3/4 N/A N/A (10)-3/4 N/A (14)-3/4 N/A (12)-3/4 (4)-3/4 (4)-1/2 Rev(s)on vJ l U Oi Z4 Star Building Systems FRAME DESCRIPTION: USER NAME:vjoseph DATE:10/25/04 TIME:11:24:04 , PAGE: 1-2 8600 S. I-35, Oklahoma City, OK 73149 smt 160./20./25. 12./130./0. JOB NAME:96509A,'., FILE:fra2thrul0.fra _ DESIGN AND ESTIMATION INFORMATION FRAME ID #OS LOCATION: frame lines 2-10 STANDARD NOTES: WEIGHT: 6881 lbs DETAIL FILE: \ENG\10-B-96509\OPEN02-vjoseph\Bldg-A\Drftg\xO1R (1) All sectional dimensions are in inches. YIELD STRENGTH(ksi) - PLATE:50, PIPE:42, TUBE:46, W.F.:50, FLG BRC:50, BOLTS:A325 SNUG TIGHT (2) All Flange lengths are measured along outer flange. PURLINS(horz. from save) :8.5"-Z 2@4'-4 7/6",14®5' GIRTS (Vert. from floor):8.5"-Z (BYPASS) I M1MCPTON nrTATLB : Location 1 1 2 3 4 5 6 7 B 9 10 Web Dep. 8.0 34.0 N/A 30.0 25.5 25.5 25.5 40.0 6.625 6.625 Type BASE HORZ STF CAP (EXT) 3E/2E SPLICE 4E/3E SPLICE 4E/2I BASE CAP/STF Plate(DN) 8.OXO.375 3.75X0.5 8.0X0.25 8.OXO. 5 N/A 6. OXO.5 N/A 6. OXO. 625 B. 0XO.625 B. OXO.375 Plate(UP) N/A N/A N/A 6. OXO.5 N/A 6. OXO.5 N/A 6. OXO. 625 N/A N/A Bo'MM 0043/4 N/A N/A (10)-3/4 N/A (14)-3/4 N/A (12)-3/4 (4)-3/4 (4)-1/2 Revision 0 12 12 ' E.H. VJ c Star Building Systems FRAME DESCRIPTION: USER NAME:vjoseph DATS:10/25/04 PAGE: 1-3 8600 S. I-35, Oklahoma City, OK 73149 smt 160./20./25. 12./130./0 JOB NAME:96509A FILB:fra2thrulO.fra SUPPORT REACTIONS FOR EACH LOAD GROUP PRAMS ID #01 LOCATION:frame lines 2-10 NOTE: All reactions are in kips and-kip-ft. ..� TIME:11:24:04 REACTION NOTATIONS VL LOAD 'GROUP'REACTION TABLE . V1 COLUMN LEFT COLUMN RIGHT COLUMN INTERIOR COLUMN 1 BASE PLATE 8.OX9.OXO.375 8.OX9.OXO.375 8.OX14.OXC.625 ANC. BOLTS (Q -3/4 W -3/4 W -3/4 LOAD GROUP HL VL LL MR VR LR H1 Vl L1 _ DL 1.3 4.8 0.0 -l'.3 5.2 0.0 0.0 6.7 0.0 LL 4.7 18.2 0.0 -4.7 18.2 0.0 0.0 24.0 0.0 -COLL 2.8 5.0 0.0 -2.8 5.0 0.0 0.0 10.1 0.0 WL1 -4.9 -26.1 0.0 4.0 -17.4 0.0 0.0 -25.3 0.0 WL2 -4.7 -15.4 0.0 1.8 -21.0 0.0 0.0 -20.2 0.0 WL3 -4.0 -17.4 0.0 4.9 -26.1 0.0 0.0 -25.4 0.0 WL4 -1.8 -21.0 0.0 4.7 -15.4 0.0 0.0 -20.3 0.0 LWB1 -5.4 -17.8 0.0 5.4 -17.8 _v 0.0 0.0 -25.5 0.0 LWB2 -5.4 -17.8 0.0 5.4 -17.8 0.0 0.0 -25.5 0.0 LOAD GROUP DL DESCRIPTION Roof Dead Load LL Roof Live Load COLL Roof Collateral Load WL1 Lateral Primary Wind Load WL2 Lateral Primary Wind Load WL3 Lateral Primary Wind Load WL4 Lateral Primary Wind Load .LWB1 Longitudinal Primary Wind Load [base only] LWB2 ' Longitudinal Primary Wind Load [base only] n , a - HR VR 10/28/2004 Revision 5 12 of 24 vJ i Star Building Systems FRAME DESCRIPTION: USER NAME:vjoseph DATE:10/25/04 PAGE: 1-4 8600 S. I-35, Oklahoma City, OK 73149 smt 160./20./25. 12./130./0 J09 NAME:96509A FILE:fra2thru10.fra MAX. SUPPORT REACTIONS FOR LOAD COMBINATIONS - FRAME_ID #01 LOCATION:frame lines 2-10 NOTES:(1) All reactions are in kips and kip-ft.. TIME:11:24:04- --• (2) These reactions are from loads determined from the applicable code for Aso design. Seismic loads are limit state and include magnification factors -when so required by the seismic provisions.•of the applicable code for ASD� esign. It is the resBonsibility of -the foundation. designer to apply the load factors and load combinations appropriate for the concrete foundation design REACTION NOTATIONS ,.. 4 HL VL LOAD COMBINATION MAXIMMM REACTION TABLE . COLUMN LEFT COLUMN RIGHT COLUMN 'INTERIOR COLUMN 1 BASE PLATE 8.OX9.OXO.375 8.OX9.OXO.375 8.0X14.9 0.625 ANC. BOLTS --(4)-3/4 ._ (4)-3/4 ` (4)-3/4 LOAD COMB - RL , VL' LLB HR I VR I LR I H1 I V1 I L1 GRAVITr LOAD COMBINATION ._ •. _. 1 1 8.91 27.9 ` 0.0 -8.91 28.3 0.0 MIND LOAD CDMB1NATION _ 21 6.4 7.6 0.0 -4.2 12.2 O.D 0.0 - 19.6 0.0 12 -4.6 -15.0 0.0 4.6 -14.7 0.0 0.0 -21.5 0.0 19 4.2 11:8 6.0 -6.4 . 8.0 0.0 0.0 19.6 0;0 8 -4.1 -23.2 0.0 3.2 -14.3 0.0 0.0 -21.3 0.0 10 -3.2 -14.61 0.0 4.1 -22.9 0.0 0.0. -21.4 0.0 LOAD COMBINATION 1 DESCRIPTION. .. DL +LL +COLL 8 0.6DL +WL1 10 0.6DL +WL3 - 12 0.6DL +LW331 19 DL +0.75LL _ +COLL +0.75WL2. 21 DL +0.75LL +COLL +0.75WL4 + L MR VR 10/28/2004 Revision 5 13 of 24 vJ Star Building Systems w FRAME DESCRIPTION: USER NAME:vjoseph' i DATE:10/25/04 TIME:11:23:53 PAGE: 2-1 8600 S. I-35, Oklahoma City, OK 73149 smt 160./20./18.083 12./130./0. JOB NAME:96509A FILE:fra1 11.fra DESIGN AND ESTIMATION INFORMATION FRAME ID. H02 -'LOCATION: frame lines 1 STANDARD NOTES: " WEIGHT: 5879 'lbe DETAIL'FILE: \ENG\10-B-96509\OPEN02-vjoseph\Bldg-A\Drftg\X02L (1) All sectional dimensions are in inches. YIELD ETRENGTH(ksi) - PLATE:50, PIPE:42; TUBE:46, W.F.:50, FLG BRC:50, BOLTS:A325 SNUG TIGHT (2) All Flange lengths are measured along outer flange. PURLINS(horz. from save) :B.S"-Z 4m2,'-2 7/16",1495' GIRTS (vent.: from floor):8':5"-Z (BYPASS) 4 Y ' G 1 20' E.H. CONNECTION DETAILS : Location 1 2 3 4 5 6 7 8 9 10 Web Dep. 8.0 26.0 N/A 25.0 19.5 19.5 19.5 35.0 6.625 6.625 Type BASE HORZ STF CAP (EXT) 3E/2E SPLICE 4E/3E SPLICE 4E/2I EASE CAP/STF Plate(DN) 8.0X0.3]5 3.]5%0.3125 a. 0%0. 25 8. 0X0.5 N/A 6.OX0.5 N/A 6. 0%0.5 8. Us.5 8. 0X0.375 Plate(UP) N/A N/A N/A 6. OX0.5 N/A 6.0%0.5 N/A G. u%0.5 N/A N/A 1(4)-1/2 AUiRQQ N/A (10)-3/4 N/A (14)-3/4 N/A (12)-3/4 (4)-3/4 Revision l4 OT Z4 Star Building Systems FRAME DESCRIPTION: USER NAME:vjoseph DATE:10/25/04 PAGE: 2-3 8600 S. I-35, Oklahoma City, OK 73149 smt 160./20./18.083 12./130 JOB NAME:96509A FILE:fral_ll.fra MAX. SUPPORT REACTIONS FOR LOAD COMBINATIONS FRAME ID #02 LOCATION:frame lines 1 NOTES:(1) All reactions are in kips and kip-ft. TIME:11:23:53 (2) These reactions are from loads determined from the applicable code for ASD design. Seismic loads are limit state and include magnification factors when so required by the seismic provisions of the applicable code for ASD design. It is the responsibility of the foundation designer to apply the load factors and load REACTION NOTATIONS, v HL -- ... VL .. LOAD COMBINATION MAXIMUM REACTIONTABLE COLUMN _ LEFT COLUMN RIGHT COLUMN INTERIOR COLUMN 1 BASS PLATE B.OX9.OXO.375 S.OX9.OXO.375 8.OX14.OXO.5 ANC. BOLTS (4)-3/4 (4)-3/4 (4)-3/4 LOAD COMB ` HL I VL I LL MR I VR 'LR H1 I Vl I L1 GRAVITY LOAD COMBINATION 1 5,9 21.0 0.0 - -5.91 21.31 0.01 0.01 30.3 0.0 WINO LOAD COMRINATFON 21 4.5 6.3 0.0 -2.6 9.6 0.0 0.0 14.7 0.0 12 -3.0 -10.4 -10.3 0.0 0.0 -15.5 0.0 19 2.6 9.3 6.6 0.0 0.0 14.7 0.0 B -2.9 -16.4 91., -9.9 0.0 0.0 -15.5 0.0 10 -1.8 -10.1 -16.2 0.0 0.0 -15.5 0.0 LOAD COMBINATION 1 DESCRIPTION DL +LL +COLL e 0.6DL +WL1 10 0.6DL +WL3 12 0.6DL +LWBI 19 DL +0.75LL +COLL +0.75WL2 21 DL +0.75LL +COLL +0.75WL4 4 MR VR 10/28/2004 Revision 5 16 of 24 vJ Star Building Systems FRAME DESCRIPTION: USER NAME:vjoseph DATE:10/25/04 PAGE: 2-4 8600 S. I-35, Oklahoma City, OK 73149 smt 160./20./1B.083 12./130 JOB NAME:96509A PILE:fra1_ll.fra USSR LOAD SCHEMATICS FRAME ID #02 LOCATION:frame lines 1 NOTE: All user loads are in kips and kip-ft. TR E:11:23:53 (1) DL 0.02 0.02 0.02 0.02 0.99 m m 1.26 'F'o`r Re�`fe-re-n`ce `O:n'I;,y`, !Iroards shfow�n are `inclad'ed iFn `rea'ctEio:n fiab'.1.,I 10/28/2004 Revision 5 17 of 24 vJ Star Building Systems FRAME DESCRIPTION: USER NAME:vjoseph DATE:10/25/04 TIME:11:24:13 PAGE: 4-1 8600 S. I-35, Oklahoma City, OX 73149 pf 25./20. main building at planes SWA JOB NAME:96509A FILE:pfra.fra DESIGN AND ESTIMATION INFORMATION FRAME ID #04 LOCATION: bays STANDARD NOTES: WEIGHT: 3667 lbs DETAIL FILE: \ENG\10-B-96509\OPEN02-vjoseph\Bldg-A\Drftg\x04L (1) All sectional dimensions are in inches. YIEL➢ STRENGTH(ksi) - PLATE:50, PIPE:42, TUBE:46, W.F.:50, FLG BRC:50, BOLTS:A325 SNUG TIGHT (2) All Flange lengths are measured along outer flange. PURLINS(horz. from save) :0"-Z GIRTS (vert. from floor): 0"-Z (4.25^OUTSET)- LEFT COLUMN 0"-Z (4.25"OUTSET)- RIGHT COLUMN Location 1 2 3 4 5 6 7 e Web Dep. 14.5 14.5 N/A 27.5 27.5 14.5 14.5 N/A Type BASE HORZ STF CAP (EXT) 4E/4E 4E/4E BASE HORZ STF CAP (EXT) Plate(DN) 10.OXO.375 4.75XO.5 10.OXO.5 10.OXO.75 C 10.OXO.75 C 30.OXO.375 4.75XO.5 30.0X0.5 Plate(UP) N/A N/A N/A 0.0XO.625 0.0X0.625 N/A N/A N/A QQ4 (4)-1 N/A N/A (16) /4 (16)-3/4 (4)-1 N/A N/A 10 Rev)s)on o VJ Star Building Systems PRAM DESCRIPTION: USER NAM:vjoseph DATE:10/25/04 PAGE: 4-2 8600 S. I-35, Oklahoma City, OK 73149 pf 25./20. main building at p JOB NAM:96509A FILE:pfra.fra SUPPORT REACTIONS FOR EACH LOAD GROUP FRAM ID #04 LOCATION:bays NOTE: All reactions are in kips and kip-ft. TIM:11:24:13 HL WAD GROUP REACTION TABLE COLUMN LEFT COLUMN RIGHT COLUMN BASE PLATE 10.OX1S.625X0.375 10.OX15.62SX0.375 ANC. BOLTS W -1 (0 -1 LOAD GROUP HL VL LL HR VR LR DL 0.1 1.7 0.0 -0,1 1.7 0.0 WL1 -16,3 -27.3 0.0 -17.2 27,3 0.0 LOAD GROUP DESCRIPTION DL Roof Dead Load WL1 Lateral Primary Wind Load 10/28/2004 Revision 5 19 of 24 vJ S't r Building Systems FRAME DESCRIPTION: USER NAME:vjoseph DATE:1O/25/04 PAGE: 4-4 56O0 S. I-35, Oklahoma City, OR 73149 pf 25./20. main building at p JOB NAME:965O9A PILE:pfra.fra USER LOAD SCHEMATICS FRAME IO #04 LOCATION:baya NOTE: All user loads are in kips and kip-ft. TIME:11:24:13 [11 WL1 33.44 r 'fF'o:r'Rre:fe`re.n�c'e �O�n �y, 10/28/2004 Revision 5 21 of 24 vJ STAR BUILDING SYSTEMS STRUCTURAL CANOPY RAFTER W/BYPASS GIRTS AT EAVE DETAILS JOB NO. 10-B-96509 DATE/BY 1012512004 VJ 1 12 1.0 O O 1 WEB DEPTH 18.93"" 8.0" TYPE 21121 PLATES 8.Ox0.625 BOLTS 3/4" PLATE: 50 ft BOATS.• A325 BRACKET.• WEB = 0.25" TOP = 8.0 x0.25" BOTTOM= 8.0'x0.25" 10/28/2004 STAR PORTAL FRAME SHEET BUILDING DETAIL (4 AB min) JOB NO. 104 9WW SYSTEMS Heavy Connection DATE/BY 0W152W4 V✓ Nears wnsry J ,K a-v4• * FILE PORTAL FRAME COLUMN HALF PORTAL COLUMN BASE PLATE WIDTH PLUS 114' m A 8114- � O O O H ElE*L INITHFLANGE FLASH AND 7' GIRTS. GIRTS. INSIDE GIRT FLANGE AT BYPASS GIRTS. B"MFRAWCO(M Revision 5 23 of 24 vJ STAR SPECIAL FLANGE BRACE SHEET BUILDING USING SQUARE TUBE JOB N0. 10-B-96059 SYSTEMS I DATE/BY 09/10/2004 vl 3/8" STITCH PLATES W/ (1)3M'0 A 325 BOLT UNLESS NOTED TS 7x7X3/16 W/ 1/2" CAP PLATES AND (4) 3/4" 4) A325 BOLTS EACH END 5'-0 1. .1 5'-0 (2) L 2-1/2 x 2-1/2 x 3/16 w/ (1) 3/4" 4) A325 BOLT EACH END UNLESS NOTED OTHERWISE 1. ALL CONNECTION PLATES 3/8" UNLESS NOTED OTHERWISE Provide Tube column 1'-0 +/- downhill of interior column/rafter connection on Roof Bays 1,3,5, 7, 9 & 10. Tube to be located to clear roof rod bracing and to clear purlin flange braces. Purlin flange braces to remain. Code Compliance Division Inspections• 2300 Virginia Avenue Ft. Pierce, FL: 34982. - O Phone: (772) 462-1553 Fm: (772) 462-1168 7107 7 77 770�% .Inspection Notes Job Address 701 KINGS HWY ---- ---- .-------- ApplicaiionType Master Permit w/subs _ Activity Type (New Date Scheduled Foundation & Slab an Permit Type Building Commercial Other Stories Inspection Area 6"10 5112". Priority Status Phone (602) 850-8627 Inspector (Code Inspector Date Inspected 425 Sewer Connect 0 Pending .. ....... . S/2212005 05/19f2005 425 232 125 Sewer Connect Underground Electric Tie Beam 0 0 3 Pending Pending Pending 91 Scott Attey 05/09/2005 awp_ones Karl Cundlff -+ — Dawn ones Dawn J no e� 05/09/2005 03224/20051 118 105 148 Column Form Board Survey Window/Door Attatchment 3 3 4 n Pending Pending c 238 Electric Rough 5 Pending 423 Plumbing Top Out 5 Pending 351 Mechanical Rough-In(ducts) 5 Pending 140 Construction Rough Framing 6 Pending 141 Insulation 7 Pending 179 Firewall 8 Pending 260 30 Day for Testing 9 Pending 165 Handicap Restrooms 9 Pending 460 Plumbing Final 9 Pending 380 Mechanical Final 9 Pending 280 Electric Final 9 Pending 801 Paving and Drainage Certific 9 Pending , 803 Parking/Handicap Sign & Stri 9 Pending 805 Environmental, Sea Turtle (D 9 Pending 808 Landscaping/Trees 9 Pending 996 Final Termite Treatment 9 Pending 457 Fire Sprinkler Final 9 Pending 180 Building Final 10 Pending 700 Fire Department Final 11 Pending 999 Final Inspection 12 Pending IVR Access 03/11/2005 110 Footer/Foundation 0 Disapproved Don Determan 03/11/2005 Dawn Jones 04/18/2005 103 Euffer Ground 0 Approved Scott Attey 04/18/2006 Mary Jackson 04/07/2005 115 Slab 0 Partial Approval Don Determan 04/0712005 Lynette Hamilton 04/04/2005 121 Termite Spray 0 Partial Approval Don Determan 04/04/2005 Dawn Jones 04/16/2005 121 Termite Spray 0 Approved Scott Attey 04/18/2005 Frank Williams 04/06/2005 900 Plan Revision 0 Approved Billy Hatcher 04/06/2005 Dawn Jones 04/18/2005 115 Slab 0 Approved Scott Attey 04/18/2005 Lynette Hamilton 04/20/2005 110 Footer/Foundation 0 Approved Scott Attey 04/20/2005 Dawn Jones 03/21/2005 232 Underground Electric 0 Rollover to Next Day Greg Smyth 03/21/2005 Dawn Jones 03/22/2005 110 Footer/Foundation 1 Partial Approval Don Determan 03/22/2005 Dawn Jones 03/07/2005 121 Termite Spray 1 Approved Don Determan 03/07/2005 Disunite Joseph 03/16/2005 420 Plumbing Rough 1 Disapproved Greg Smyth 03/1612005 Dawn Jones 03/03/2005 104 Compaction Test 1 Approved Dawn Jones 03/03/2005 Dawn Jones 03/25/2005 119 Stem wall 1 Approved Scott. Attey 03/25/2005 Dawn Jones 03/07/2005 110 Footer/Foundation 1 Approved Don Determan 03/07/2005 Judy Brenner 03/17/2005 420 Plumbing Rough 1 Disapproved -Reinspect Fr Greg Smyth 03/17/2005 Mary Jackson 03/21/2005 420 Plumbing Rough 1 Approved Greg Smyth 03/21/2005 2400 Rhode Island Avenue Ft Pierce, FL 34950 L, .1. , ^ram � • ST LUCIE COUNTY FIRE DISTRICT BUREAU OF FIRE PREVENTION PLAN REVIEW Telephone: 772-462-8306 FAX: 772-462-8466 !., ( ew Construction ( )Tenant Improvement ( )Addition ( )Renovation/alterations ( )Shell Only Jurisdiction: SLC F.P.B.: B-04-583 Occupancy: Builders First Choice - Truss Bldg. C. Building Dept: 24101904 Address: 710 S. Kings Hwy. Number of stories: Contractor Mark Construction Phone # 407-831-6275 Contractor's Address:, 421 Gold Medal Court City: Longwood State: FL Zip Code: 32750.."'- ' Architect/Engineer: Stephen A. Brock Architects, Inc. Phone# 561-622-4480 Building Owner: �• Review Date:,-; 1/3/2004 Occupancy Type: Industrial ' Automatic sprinklers: {r . Gross sq ft: 41,600 Net sq ft: Occupant Load: Based On: Construction Type: SBCCI Type: IV unp . :NOTE 1. All revisions must be in compll�nce before the final inspection. 2. The Fire Marshal requires 24 hour notice on all inspections. 3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 4. Permit fees are required to be paid in full prior to any inspections. 5. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. A copy of the required revision/s have been transmitted to the Architect () Contractor ( ). 7. Penetrations through rated assemblies shall be of proper UL design. 8. UL design criteria shall be submitted with the construction plans. 9. Fire Alarm Panels shall be located indoors. THE FLORIDA FIRE PREVENTION CODE, 2001 EDITION IS CURRENTLY ENFORCED. REVISIONS REQUIRED ACCESS BOX IS REQUIRED ( ) ACCESS KEY SWITCH REQUIRED ( ) 1. Provide portable fire protection throughout. Reviewed by: Date: 1/3/2004 n rl• �, 2r n + � S ST LUCIE COUNTY FIRE DISTRICT BUREAU OF FIRE PREVENTION PLAN REVIEW (D 2400 Rhode Island Avenue Ft Pierce, FL 34950 ew Construction ( )Tenant Improvement ( )Additior Jurisdiction: SLC Occupancy: Builders First Choice Manufac. Bldg. A Address: 710 S. Kings Hwy. Contractor Mark Construction Contractor's Address: 421 Gold Medal Court State: FL Architect/Engineer: Stephen A. Brock Architects, Inc. ' Building Owner: Occupancy Type: Industrial Gross sq ft: 72,405 Occupant Load: Construction Type: Telephone: 772-462-8306 FAX: 772-462-8466 ( )Renovation/alterations F.P.B.: Building Dept: - Number of stories: '�'Phone # NCity: -Zip Code: Phone # Review Date: Automatic sprinklers: Net'sq ft: Based On:.. SBCCI Type: ( )Shell Only B-04` 582 24100909 s 407-831-6275 Longwood 327,50 '561-622-4480 '12/2612004 .Required IV urip NOTE 1. All revisions must be in compliance before the final inspection. 2. The Fire Marshal requires 24 hour notice on all inspections. 3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 4. Permit fees are required to be paid in full prior to any inspections. 5. Failed inspections require payment of fee,prior to rescheduling of further inspections. 6. A copy of the required revision/s have been transmitted to the Architect () Contractor ( ). ,. 7. Penetrations through rated assemblies shall be of proper UL design. , 8. UL design criteria shall be submitted with the construction plans. 9. Fire Alarm Panels shall be located indoors. THE FLORIDA FIRE PREVENTION CODE, 2001 EDITION IS CURRENTLY ENFORCED. p REVISIONS REQUIRED ACCESS BOX IS REQUIRED ACCESS KEY SWITCH REQUIRED( ) 1. A separate permit is required for the jnstallation of the fire sprinkler system. Monitoring is required. �. 2. A "separate permit is required for the installation of the fire alarm system. 3. Provide.an exit light fixture above door number 213. 4. Automatic fan shutdown is required for the HVAC systems. Provide duct -detectors in the supply air. Reviewed by: y�, Date: 12/28/2004 ounry g Department iAenue ,L 34992 .1 1553 hid -Load Compliance. euetneer. This Certification must be submitted with all dense (single or multi• family), residential addition, any structure. This Certification shall not apply to interior, component is being effected) and certain other minorbuilding­ Difice at 462-1553 or 462-2172. . TrVjOCE NiM& ata wars Sr Office Use Only Sweet Address ! Icimstruction Permit Numb" Occutiancy TYL)c Type NT_ Certification Statement: Lcertify.ow:.ta ffic.licst of&y.. XnmlWjp-..and be I hef, these plans and specifications have been deiigned to comply wi6ifiiapplicable structural portion of the Building Codes currently adopted and enforced by St. Lucie ,County.A.also ceitify that depicted on these plans provide adequate resistance to the wind loads and f6rces specified by.currint code. Provisions." DcslZn Parameters and Assumptions Used: ME(please check or complete the appropriate box.) I-Morida Building Code-Idiflon ASCE 7-98 2. Building Design is (check Parliaily-Enclosed-_ Open Building- 3. Building Height, Wind -Speed -Used in Building Design: l30 3 second gust 5. Wind Exposure Classification (refer to exposure tables In Building Code Identified in Tine #i): 6. Average Wind VieFocity. Faces orStructure __9-!_PSF 7. Peak Wind Velocity Pressure on Exterior Faces of Structure' _PSF & 9.-Loads:. . Floor iV0_0M R@4dc&d.-2__c0PSF Roofilive _2.0 PSF 10. Were Shear Walls'Considered for Structure (check one): Yes ✓ No —(if No, attach explanation) tes V' No T (if No, attach explanation): 17. Are Component and Cladding Detail Provided (check one): Yes No explanation). —(if No, attach expla on Li-minimuins,oit.Bearwirre*suer. - -S06bPSF:,_ As witnessed itnessed by my seal, I hereby certify that the information induided with this certification Is true and correct, to the best of -my Knowledge andIelkf.-, Rx re'u a Name: Certificafien't'. Isqa, Hem) T: Design Firm, Lu oy Ditc: 9bCCDV Form 0 02M 7W_10� Product Review Affidit St Lucie County, Public Works Department Code Compliance Division The following products will be installed in the structure located at Building Permit.# 2390-M.-Camelback-Road, Suite..,210 Owners Name NSHE Hardinsburg, LLO gwner's,Address Phoenix, AZ 85016 Contractor's,Address 421 Gold Medal Court Contractor Mark 'Construction Co�. , _ ` Longwood, Florida 32750 Product *Product Rated Desi Pressures Manufacturer Model Numtier Method of Attachment Windows ' - "Fill [if the rated wind design pressures fisted by the manrrfdeturerfor each product listed .1st Choice 130. YQi YES45FS OA # 03-0801-04 Mullions fixed Glass _ 1st Choice 130 ,' YRK YES45FS OA P 03-0801-04 Skylights Glass (other) Butt Glass Glass Block N-A. ` Sliding Glass Doors 1st Choice 2nd Choice ,J,, N.A. Swink Type Doors IstChoice On NOA as Lis. Steelcraft: 1116 Required 2nd Choice v, ,w 130 YRR 20D DA # 03-0801-06 Overhead Garage Doors ._ a , . - 1st Choice 37 —42 Clopay 524146 Required 2nd Choice ,u w +31.41-34.5 Cookson FCFLAB Required Roofing Material 7.1 Asphalt/Fiberglass N-A. Metal 52_5 psf Star Starshield Standing Seam Clip Other (Metal) 52.5 .psf Star Durarib Thru Fastened butters Choice N-A. I have reviewed the above components and cladding, and have approved their use iti e provide adequate resistance to the wind loads and forces specified by Curren a _vs Name: Signature Design Firm J�J X /�Gle Cert. No.__��_YZ 'Date: to - •. It O R.11 D�_A a, 71 The followingproducts will be ii stalled in the stricture located at s Building Permit 2390 E. Camelback Road, Suite 210 Owners Name _ NME Hardansburg, LLC Owner's Address Phoenix, Az 85016 Contractor Nark, Conscraction Co. Contractor's Address 421 Gold Medal Court Longwood, Florida 32750 Al Product *Product Rated Manufacturer Model:Number Method of Attachment Design Pressures N'Viudows tr Fill in the rated wind design pressures listed by the raanrrjactnrerjor each pYbdriet)listed Firoduc$ Review Affidavit St Lucie County, Public Works Deparhnent Code Compliance Division 1st Choice 130 YKIC YES45FS O® $ •03-0801. 04'• Mullions iced Glass -I st Choice Skylights i Glass (other) 130 f YKK Butt Glass N.A. Glass Block N.A. Sliding Glass Doors 1st Choice 2nd Choice „f.� N.A: Swing Type Doors IstChoice on NOA as lis Steelcraft" H16 s Required 2nd Choice,s,� 130 YRx 20D OA # 03-0801-06 Overhead Garage Doors 1st Choice 37 —42 „ I Clopay 524116 Required 2nd Choice,,(,o .. 31.4/-34.5 , . Cookson FCFLAB Required Roofing Material Asphalt/Fiberglass N.A. Metal 52.5 psf Star Starshield Standing Sean,Clip .1 IOtlfer'(Netal) '523 psf Star Durarib Thru Fastened 'butters , Choice I have reviewed the:above components and cladding, and have approved provide adequate resistance to the wind loads and forces specifiedAbycu Name: Signature Design Firm Celt. No.---_� - ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge FlaCom v1.22 FORM 40OA-2001 Whole Building Performance Method for Commercial Buildings Jurisdietion: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000) Short Dese: PRO SOURCE Project: PRO SOURCE OFFICE Owner: Enter Owner's name here Address: Enter Address here Enter Address here City: FT. PIERCE State: FLORIDA PermitNo: ;L `i 10 1 °1 O' Zip: 0 Storeys: 1 Type: Office (Business) GrossArea: 3120 Class: New Finished building Net Area: 3120 Max Tonnage: /.'(if different, write c � Compliance Summary Component Design Criteria Result Gross Energy Use 93.07 100.00 PASSES Other Envelope Requirements - A PASSES LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES PASSES PASSES PASSES PASSES PASSES Yes/No/NA IMPORTANT NOTE. An input report Print -Out from EnergyGauge FlaCom of this design building must be submitted along with this Compliance Report. 11/9/2004 EnergyGauge FlaCom FLCCSB v1.22 1 COMPLIANCE CERTIFICATION: I hereby certify that the plans and Review of the plans and specifications covered by this specifications covered by this calculation are calculation indicates compliance with the Florida Energy in compliance with the Florida Energy Code. Before construction is completed, this building will be Efficiency Code, inspected for compliance .in accordance with Section 553.908, F.S. PREPARED BY: oBUILDING OFFICIAL: DATE: / DATE: I hereby certify that this building is in compliance with the Florida Energy Efficiency Code. OWNER AGENT: DATE: If required by Florida law, I hereby certify (') that the system design is in compliance with the Florida Energy Code. REGISTRATION No. I n ARCHITECT: S�tphGv� rod< ANC.0007 (03e ELECTRICAL SYSTEM DESIGNER: G e f3. Rw5 F No. 3)-3 %. O LIGHTING SYSTEM DESIGNER: MECHANICAL SYSTEM DESIGNER: PLUMBING SYSTEM DESIGNER: (') Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. 11/9/2004 EnergyGauge FlaCom FLCCSB v1.22 Project: PRO SOURCE Title: PRO SOURCE OFFICE Type: Office (Business) Location: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000) (WEA File: DAYTONABEA Whole Building Compliance _Design Reference Total 93.07 100.00 ELECTRICITY 93.07 100.00 AREA LIGHTS 16.58 23.33 MISC EQUIPMT 9.70 9.70 PUMPS & MISC 0.09 0.09 SPACE COOL 21.87 22.06 VENT FANS 44.82 44.82 Credits & Penalties (if any): Modified Points: = 93.07 PASSES Project: PRO SOURCE Title: PRO SOURCE OFFICE Type: Office (Business) Location: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000) (WEA File: DAYTONABEA Other Envelope Requirements Item Zone Description Design Limit Meet Req. PrOZo2Rf1 PrOZo2 Exterior Roof -Max Uo Limit 0.05 0.09 Yes Meets Other Envelope Requirements 11/9/2004 EnergyGauge FlaCom FLCCSB v1.22 3 External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or it) None Project: PRO SOURCE Title: PRO SOURCE OFFICE Type: Office (Business) Location: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000) (WEA File: DAYTONABEA Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- D) (sq.ft) Tasks CP CP ance PrOZolspl 26 Offices (Partitions>4.5ftbelow 1,560 1 2 2 PASSES ceiling) Enclosed offices, all open plan offices without partitions PrOZo2Sp1 26 Offices (Partitions>4.5 ft below 1,560 1 4 2 PASSES ceiling) Enclosed offices, all open plan offices without partitions PASSES 11/9/2004 EnergyGauge FlaCom FLCCSB v1.22 Project: PRO SOURCE Title: PRO SOURCE OFFICE Type: Office (Business) Location: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000) (WEA File: DAYTONABEA System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 65000 Btu/h Cooling Capacity Air Handling Air Handler (Supply) - System -Supply Constant Volume 10.00 10.00 9.30 PASSES 0.80 0.80 PASSES PrOSy2 System 2 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled <65000 Btu& Cooling Capacity Au Handling Air Handler (Supply) - System -Supply Constant Volume 10.00 10.00 8.30 PASSES 0.80 0.80 PASSES PASSES Plant Compliance Description Installed Size Design Min No Eff Eff Design Min Category Comp IPLV IPLV liance None Water Heater Compliance Description Type Category D Design Min Design Max Comp Eff Eff Loss Loss liance None 11/9/2004 EnergyGauge FlaCom FLCCSB v1.22 Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/br Thick [in] Thick [in] [F] SF.FJ None Project: PRO SOURCE Title: PRO SOURCE OFFICE Type: Office (Business) Location: ST LUCIE COUNTY, S Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Electrical 413.1 Metering criteria have been met Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it El Report 101 Input Report Print -Out from EnergyGauge F1aCom attached? El 11/9/2004 EnergyGauge FlaCom FLCCSB v1.22 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge FlaCom v1.22 INPUT DATA REPORT Proiect Information Project Name: PRO SOURCE Orientation: North i Project Title: PRO SOURCE OFFICE Building Type: Office (Business) Address: Enter Address here Building Classification: New Finished building Enter Address here No.of Storeys: 1 State: FLORIDA Zip: 0 GrossArea: 3120 Owner: Enter Owner's name here Zones No Acronym Description Type Load Profile Area Multiplier Total Area lsil lsfl b 1. , PrOZol Zone 1 CONDITIONED Uses Building Load 1560.0 1 1560.0 ❑ Profile 2 PrOZo2 Zone 2 CONDITIONED Uses Building Load 1560.0 1 1560.0 ❑ Profile ll/.9/2004 EuergyGauge FlaCom FLCCSB v1.22 1 0 t Spaces No Acronym Description Type Depth Width height Multi Total Area Total Volume IN IN [ft] plier [sf] len In Zone: PrOZol 1 Pr0ZolSpl ZoOSpl Offices (Partitions>4.5 ft 26.00 60.00 8.00 1 12480.0 El below ceiling) Enclosed offices, all open plan offices without partitions In Zone: PrOZo2 1 PrOZo2Spl ZoOSpl Offices (Partitions>4.5 ft 60.00 26.00 8.00 1 1560.0 12480.0 below ceiling) Enclosed offices, all open plan offices without partitions Lighting No Type Power Control Type No.of [W] Ctrl pts In Zone: PrOZol In Space: Pr0Zo1Sp1 i Suspended Fluorescent 2000.00 Manual On/Off 2 ❑ In Zone: PrOZo2 In Space: Pr0Zo2Sp1 1 Suspended Fluorescent 2000.00 Manual On/Off 4 ❑ Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: PrOZol 11/9/2004 EnergyGauge F1aCom FLCCSB v1.22 I PrOZolWal 5/8" stucco 60.00 8.00 1 480.0 West 0.2067 5.7314 34.65 4.84 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZolWa2 5/8" stucco 60.00 8.00 1 480.0 East 0.2067 5.7314 34.65 4.84 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 3 PrOZolWa3 5/8" stucco 38.00 8.00 1 304.0 North 0.2067 5.7314 34.65 4.84 /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 4 PrOZol Wa4 5/8" stucco 38.00 8.00 1 304.0 South 0.2067 5.7314 34.65 4.84 Ej /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp In Zone: PrOZo2 1 PrOZo2Wa1 0.75 in. stucco, 60.00 8.00 1 480.0 East 0.1118 1.1829 14.94 8.94 Ej 2x4xl6" oc, RI Matt, 0.5 in. gyp 2 PrOZo2Wa2 0.75 in. stucco, 60.00 8.00 1 480.0 West 0.1118 1.1929 14.94 8.94 ❑ 2x4xl6" oc, R11Batt, 0.5 in. gyp 3 PrOZo2Wa3 0.75 in. stucco, 26.00 8.00 1 208.0 North 0.1118 1.1829 14.94 8.94 ❑ 2x4xl6" oc, RI Matt, 0.5 in. gyp 4 PrOZo2Wa4 5/8" stucco 26.00 8.00 1 208.0 South 0.2067 5.7314 34.65 4.84 /8"CMU/3/4"ISO BTWN24"oc/.5" GYP Windows No Description Type Shaded UCen SC Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sf] In Zone: PrOZol In Wall: PrOZo1Wa2 ] PrOZolWa2Wi1 SINGLECLEAR No 1.0018 0.95 0.88 3.00 5.00 1 15.0 21 ll/?/2004 EnergyGauge FlaCom FLCCSB vl.22 Skylights No Description Type UCen Shading Vis.Trans W H (Effet) Multiplier Area Total Area [Btu/hr sf F] Coeff [ft] [ft] [91 [Sf] In Zone: In Roof: 01 Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sE F] [Btu/sL F] [Ib/cf] [h.sf.FBtu] In Zone: PrOZol 1 PrOZolFll I ft. soil„concrete 60.00 26.00 1 1560.0 0.1745 54:00 108.00 5.73 ❑ floor, carpet and rubberpad Systems PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV I Cooling System (Air Cooled < 65000 Btu/h Cooling 60000.00 10.00 8.30 ❑ Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - 2000.00 0.80 ❑ Constant Volume) 11/9/2004 EnergyGauge FlaCom FLCCSB v1.22 5 PrOSy2 System 2 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Hfficiency ITLV 1 Cooling System (Air Cooled < 65000 Btu/h Cooling 60000.00 10.00 8.30 ❑ Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - 2000.00 0.80 ❑ Plant Equipment Category Size Inst.No 1 ff. IPLV Water Heaters W-Heater Description Capacit Cap,Unit i/P at. ]Efficiene Loss �i.t-Lig�ltua�� Description Categories. Area/Len/No. of units [sf/fft/No] Wattage fWj b Piping No Type Operating Insulation Temperature Conductivity [r? (Bku-in/h.sf.Fj Nomonal pipe Diameter finj Insulation Is Runout? Thicknesg [in] 11/9/2004 PnergyGauge F1'aCom FLCCSB v1.22 6 Fenestration Used Name Glass Type No. of Glass Conductance SC VLT Frame Conductance Absorptance Frame Panes [$tu/h.sf.Fl [Btn/h.sf.F1 ApLbWndl SINGLE CLEAR 1 1.0018 0,9500 0.8810 0.4340 0.7000 ❑ Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sf.F/Btu1 [fil [Btu/h.ft.F1; [lb/eq [Btu/lb.F] 18 MatII8 2 in. Wood No 2.3857 0.1610 0.0700 37.00 0.3900 ❑ 264 Mat1264 ALUMINUM, 1/16IN No 0.0002 6.0050 26.0000 480.00 0.1000 ❑ 214 Mat1214 POLYSTYRENE, EXP., No 5.2100 0.1042 0.0200 1.90 0.2900 ❑ MAIN, ❑ 187 MatII87 GYP OR PLAS No 0.4533 0.0417 0.0520 50.00 0.2000 BOARD,1/2I14 206 Mat1206 CELLULOSE,FI1,L,5.5IN,R- No 26.8318 0.4583 0.0220 3.00 0.3300 20 ' 151 Mat1151 CONC 14W, DRD,140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 41N 178 Mat1178 CARPET W/RUBBERPAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 1 6 in. Heavyweight concrete No 0.5000 6.5000 1.0000 140.00 0.2000 ❑ 123 Mat1123 CONCBLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 MW,8IN,HOLLOW 159 Mat1159 CONC No 0.3202 0.3333 1.0410 M0.00 0.2000 ❑ HW-UNDRD-140LB-41N 57 MOM 3/4 in. Plaster or gypsum No 0.148.8 6.0625 0.4200 100.00 0.2000 ❑ 72 Mat172 AIR LAYER, 3/4IN OR Yes 0.9000 ❑ LESS, VERT, WALLS 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 �] 266 Mat1266 2x4@16" oc+k11 Batt No 8.3343 0.2917 0.0350 9.70 0.2000 ❑ 11/9/2004 EnergyGauge F1aCom FLCCSB v1.22 287 Mat1287 Polyurethane core (24 ga Yes 4.1500 ❑ steel) 2 ❑ 288 Mat1288 Solid Urethane foam core Yes 4.1'500 81 Matl81 ASPHALT -ROOFING, Yes 0.1500 ❑ ROLL 244 Matl244 PLYWOOD, 1/21N No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ 185 Matll85 CLAY TILE, PAVER, 3/8IN No 0.0301 0.0313 1.0410 120.00 0.2000 ❑ 82 Mat182 ASPHALT -SHINGLE AND Yes 0.4400 ❑ 11 Matll 1 SIDING 2 in. Insulation No 6.6900 0.1670 0.0250 2.00 0.2000 ❑ 47 Mat147 2 in. Heavyweight concrete No 0.1670 0.1670 1.0000 140.00 0.2000 ❑ 95 Matl95 CONC BLOCK No 0.7107 0.3333 0.4690 101.00 0.2000 ❑ HW4IN-HOLLOW 248 Mat1248 ROOF GRAVEL OR No 0.0500 0.0417 0.8346 55.00 0.4000 ❑ SLAGI/2IN 94 Mat194 BUILT-UP ROOFING, No 0.3M6 0.0313 0.0930 70.00 0.3500 ❑ 3/8IN Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1002 Aluminum door, 1.25 in. polystyrene No No 0.19 033 43.67 5.2104 ❑ Layer Material Material Thickness Framing No. [it] Factor 1 264 ALUMINUM, 1/16114 0.0050 0.00 ❑ 2 214 POLYSTYRENE, EXP., 1-1/4IN, 0.1042 0.00 ❑ 3 264 ALUMINUM, 1116IN 0.0050 0.00 ❑ 11/9/2004 EnergyGauge FlaCom FLCCSB v1.22 9 Simple 11+Yass1'ess Condu'efauce Heat Capacity Density RValue Name Construct Construct [13tu/h.s£F] [)3tuAf.F] [lb/cf [h.s£.F/Btuj 1005 FFNo 1 ft. soil, concrete floor, carpet and rubber pad No No 0.17 54.00 108.00 5.7300 C] Layer Material Material Thickness Framing No. [ft]' Factor 1 265 Soil, 1 ft 2.0000 0.00 ❑ 2 48 6 in. Heavyweight concrete 0.500.0 0.00 ❑ ', 3 178 CARPET W/RUBBER PAD 0.00 Simple massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/b.S£F] [$tuM.F] []h/cn ]hsfFBtu] 1009 0.75 in. stucco, 2x4xl6" oc, R11Batt, 0.5 in. No No 0.11 1.18 14.94 8.9438 ❑ gyp I Layer Material Material Thickness Framing No. [ft] Factor 1 267 0.75" stucco 0.0625 0.00 ❑ 2 266 2x4@16" oc+R11 $att 0.2917 0.00 d 3 187 GYP ORPLAS BOARD,1/21N 0.0417 0.00 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct. Constritet [i3tu/h.sf.F] [Btii/sf.F] [lb/cf] [hsfF/ 1 1011 5/8" stucco /8"CMU/3/4180 No No 0.21 5.73 34.65 4.8368 ❑ BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. [£t] Factor 1 268 0.625" stucco 0.052.1 0.00 ❑ 2' 42 8 In. Lightweight concrete block 0.6670 0.00 13 3 269 .75" ISO BTWN24" oc 0.0625 0.00 ❑ 4 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.00 ❑ 11/9/2004 $nergyGauge FlaCom FLCCSB v1.22 10 No Name Simple Construct Massless Conductance Construct [Btu/h.sf.F] Heat Capacity [Btu/sf.F] Density [lb/cf] RValue [b.sEF/Btn] 1039 Shngl/1/2"WD Deck/WD Truss/6'Batt/Gyp No No 0.05 1.40 10.89 21.2351 ❑ Brd Layer Material Material Thickness Framing No. [ft] Factor 1 81 ASPHALT -ROOFING, ROLL 0.00 ❑ 2 244 PLYWOOD, 1/2IN 0.0417 0.00 ❑ 3 23 6 in. Insulation 0.5000 0.00 ❑ 4 187 GYP OR PLAS BOARD,1/2IN 0.0417 0.00 ❑ 11/Q/2004 EnergyGaugeFlaCom FLCCSB v1.22 11 e Sheet i PLANS t 0.240 dm 13, `240 cfm 2000 dm �243 dm 0.229 cfm WOMEN LUNCH RM MEN 0.87dm [� 0.243 dm PLANS 2 1240 dm �240 dm 0.237 dm Job #: PRO SOURCE Scale: 1 : 121 Performed by WG for: Page 1 Right -Suite Commerclal PRO SOURCE 5.0.17 RSC60847 LUNCH/OFFICE 2004-Nov-09 15:11:58 FT. PIERCE, FL 34945 C:1My Documents\Wrightsoft WA... SECOND FLOOR 2000 dm 0.,4, dm [� [� OFFICE 3 0.229 dm 1229 dm 1229 d 0.,4, dm GENERAL OFFICE I� 0.,73 dm \229 dm 0. OFFICE 2 229 dm 229 0.173 dm Job M Performed by WG for: PRO SOURCE LUNCH/OFFICE FT. PIERCE, FL 34945 PRO SOURCE Scale: 1 : 121 Page 2 Right -Suite Commercial 5.0.17 RSC50847 2004-Nov-09 15:11:58 CAMy DocumentsMrightso$ HVA... Right -Suite Commercial Load Summary It UNIT TWO PRO SOURCE Job: 111612004 Project Information For: PRO SOURCE LUNCH/OFFICE, FT. PIERCE, FL 34945 Zone: ON(T TWO ` COOLING'IOAD 1. DESIGN CONDITIONS at Jul 1500 Peak load at Jul 1500 Inside: 75 OF Outside: 90 OF TD: 15 OF RH: 50 % Moisture: 61.4 gr/lb Mult: 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 5693 - 3. TRANSMISSION GAINS Sensible 9843 - Walls: 1369 - - Glass: 2172 - - Doors: 110 - - Partitions: 0 - - Floors: 0 - Roofs/Ceilings: 6192 - Return Air Ceiling: 0 4. INTERNAL HEAT GAIN Sensible Latent 19020 2069 Occupants: 2587 2069 - - Lights: 12726 - Motors: 0 - Appliances: 3707 0 - - 5. INFILTRATION: Outside air cfm: 10 165 425 6. SUBTOTAL: Space load 34720 11281 7. SUPPLY DUCT 1042 - 8. SUBTOTAL: Bldg comp's and supply duct 35762 Actual cfm: 2000 at Supply TD: 20 - - 9. VENTILATION: Make-up air cfm: 207 3414 8787 10. RETURN AIR LOAD: Lighting & roof (net) 0 - 11. RETURN DUCT 0 - 12. TOTAL LOADS ON EQUIPMENT 39176 11281 HEATING LOAD: 13. DESIGN CONDITIONS MUIt: 1.0 Inside: 70 OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 13395 Walls: 2240 - Glass: 4435 - Doors: 212 - Partitions: 0 - Floors: 3901 - Roofs/Ceilings: 2607 - Return Air Roof: 0 - 15. INFILTRATION: Outside air cfm: 82 2528 16. SUBTOTAL: Building components 15923 17. SUPPLY DUCT: 478 18. VENTILATION: Make-up air cfm: 207 6374 19. HUMIDIFICATION 1569 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPMENT 24344 wrrghtsoft Right-Suhe Commemia15.0.17 RSC5o847 2004-NOv 0915:12:09 C-.Wy DowmentslWnghtsofl WAMPRO-SOURCE OFFICE-LUNCH.Mc Page i Right -Suite Commercial Load Calculation ti PLANS 1 PRO SOURCE Job: 11/6/2004 For. PRO SOURCE LUNCH/OFFICE, FT. PIERCE, FL 34945 Zone: PLANS l." LWH: 13.0 x 16.0 x 8.0 1. DESIGN CONDITIONS - COOLING ( Jul 1700 ) . Dry Bib RH Moisture Range Wet Bib Outdoor Conditions 89 62 15 78 Indoor Conditions 75 50 63 TOD Correction 2 Difference 14 61.4 i Mult = 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Lat = 27.45 °N Const Wt = M ) Type Orien Shad Tilt %ovr Area Sc Shgf Shad Sens n/a 0 n/a 0 0 0.00 0 0.0 0 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens WALL 3 N 128 128 0.137 D 16.5 N D 289 WALL 3 W 104 83 0.137 D 24.5 N D 279 DOOR 6 w 21 21 0.360 13.5 102 FLOR 1 - 29 29 0.810 0.0 0 4. INTERNAL HEAT GAIN Sens Latent PEOPLE Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 0 1 250 200 347 277 8to6 0 0 0 0 0 0 0 wnghtsoft Right -Suite Co etcial5.0.17 RSC50847 2004-NOV-0916:12:27 CWy D=aneetsMhightsaft HVACIPRO-SOURCE OFFICE-LUNCH.me Page 1 • LIGHTS Type Total Factor Space Schedule W/ftz W W Btuh/W Tract Fluorescent 2.00 0 416 4.10 1.0 1706 8to6 Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 PLUG LOADS / APPLIANCES - Application Usage Total Sensible Latent Schedule Btuh Btuh Plug load W/ft' W 8to6 0.7 0 1.00 146 3 0 497 0 #/ft' # 0.0 0 1.00 0 0 0 0 0 #/ft' # 0.0 0 1.00 0 0 0 0 0 #Ift' # 0.0 0 1.00 0 0 0 0 0 #/ft' # 0.0 0 1.00 0 0 0 0 0 #/ftz # 0.0 0 1.00 0 0 0 0 0 MOTORS Power (hp) Load Total Sensible Schedule #/ft2 # factor Btuh 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 5. INFILTRATION Sens Latent 10 cfm -> x db Temp Diff 13.5 x 1.10 149 -> x Moist. Diff 61.4 x 0.69 425 6. SUBTOTAL COOLING LOAD FOR SPACE 3368 1880 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 101 S. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 3469 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling Cfm = ( 3469) / (1.10 x 20.0 ) = 158 Actual Cooling Fan > = 229 9. VENTILATION ' 28 cfm -> x db Temp Diff 13.5 x 1.10 412 -> x Moist. Diff 61.4 x 0.69 1178 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Lights Total power (W) 0 1706 RA Roof Load from Line 3 (+) 0 RA Ceiling Load Credit - from Line 3 (-) 0 wnghtsoft Right -Suite Commerclai5.0.i7RSC50847 2004-Nov-0915:12:27 C:wiy Dowmems\wrigmsoft HVAC\PRO-SOURCE OFFICE-LUNCH.r= Page 2 11. RETURN DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 3880 1880 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TO = (Inside DB - Outside DB) _ ( 70 - 42) = 28 Mult = 1.0 ] — 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss WALL 3 N 128 128 0.137 28.0 491 WALL 3 W 104 83 0.137 28.0 318 DOOR 6 w 21 21 0.360 28.0 212 FLOR 1 29 29 0.810 28.0 658 15. INFILTRATION Loss 28 cfm x db Temp Diff 28.0 x 1.10 872 16. SUBTOTAL HEATING LOAD FOR SPACE 2551 17. SUPPLY DUCT HEAT LOSS 77 Loss factor 0.03 x Line 16 Loss 18. VENTILATION 854 28 cfm x db Temp Diff 28.0 x 1.10 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 0.0 (Max = 52.0 for 2 pane ) 56 cfm x 3.20 g/100cfm/d = 1.8 gpd 678 20. RETURN DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 4160 wnghtsoft Right-Sufle Commercial 5.0.17 RSCS0847 2004-Nov 0915:12:27 C:Vy DocumemslWrightsoft HVACTRO-SOURCE OFFICE-LUNCH.mc Page 3 Right -Suite Commercial Load Calculation PLANS 2 PRO SOURCE Job: 1116/2004 For: PRO SOURCE LUNCH/OFFICE, FT. PIERCE, FL 34945 Zone: PLANS 2 - LWH: 13.0 x 16.0 x 8.0 1. DESIGN CONDITIONS - COOLING ( Jul 1700 ) Dry Bib RH Moisture Range Wet Bib Outdoor Conditions —> 89 62 15 78 Indoor Conditions > 75 50 63 TOD Correction 2 Difference 14 61.4 i Mult = 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Lat = 27.45 ON , Const Wt = M ) Type Orien Shad Tilt %ovr Area SC Shgf Shad Sens n/a 0 n/a 0 0 0.00 0 0.0 0 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens WALL 3 S 128 128 0.137 D 22.8 N D 400 WALL 3 W 104 83 0.137 D 24.5 N D 279 DOOR 5 w 21 21 0.360 13.5 102 FLOR 1 - 29 29 0.810 0.0 0 ROOF 1 - 3 3 0.060 R4 67.5 D 11 4. INTERNAL HEAT GAIN Sens Latent PEOPLE Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 0 1 250 200 347 277 8to6 0 0 0 0 0 0 0 wnghtsoft RIgM-Suite Commemlal S.0.17RSC50947 2004-Nov0915:12:27 C:1AAy DowmentslWAghtsoft HVAMPRO-SOURCE OFFICE-LUNCH.Me Page 1 • LIGHTS Type Total Factor Space Schedule W/ft2 W W BtuhNV Tract Fluorescent 2.00 0 416 4.10 1.0 1706 8to6 Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 PLUG LOADS / APPLIANCES Application Usage Total Sensible Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6 0.7 0 1.00 146 3 0 497 0 #/ftz # 0.0 0 1.00 0 0 0 0 0 #/ft' # 0.0 0 1.00 0 0 0 0 0 #/ft2 # 0.0 0 1.00 0 0 0 0 0 #Ifta # 0.0 0 1.00 0 0 0 0 0 #/ft' # 0.0 0 1.00 0 0 0 0 0 MOTORS Power (hp) Load Total Sensible Schedule #/ft2 # factor Btuh 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 5. INFILTRATION Sens Latent 10 cfm -> x db Temp Diff 13.5 x 1.10 149 -> x Moist. Diff 61.4 x 0.69 425 6. SUBTOTAL COOLING LOAD FOR SPACE 3489 1880 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 105 S. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 3593 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 3593) / (1.10 x 20.0 ) = 163 Actual Cooling Fan > = 237 9. VENTILATION 28 cfm -> x db Temp Diff 13.5 x 1.10 412 -> x Moist. Diff 61.4 x 0.69 1178 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Lights Total power (W) 0 1706 RA Roof Load from Line 3 (+) 0 RA Ceiling Load Credit from Line 3 (-) 0 wrightsoft Right -Suite Commercial 5.0.17RSC50847 2004-Nov-0915:12:27 C,.XMy DocumeRslWrightsoft HVACTRO-SOURCE OFFICE-LUNCH.me Page 2 11. RETURN DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) - 4005 1880 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating , TD = (Inside DB - Outside DB) 14. TRANSMISSION LOSSES Type Expos GrArea NetAresi Uval WALL 3 S 128 128 0.137 WALL 3 W 104 83 0.137 DOOR 5 w 21 21 0.360 FLOR 1 29 29 0.810 ROOF 1 3 3 0.060 _ ( 70 - 42) = 28 Mult = 1.0 ] — HTD_ Loss 28.0 491 28.0 318 28.0 212 28.0 658 28.0 4 15. INFILTRATION Loss 28 cfm x db Temp Diff 28.0 x 1.10 872 16. SUBTOTAL HEATING LOAD FOR SPACE 2556 17. SUPPLY DUCT HEAT LOSS 77 Loss factor 0.03 x Line 16 Loss 18. VENTILATION 854 28 cfm x db Temp Diff 28.0 x 1.10 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 0.0 (Max = 52.0 for 2 pane ) 56 cfm x 3.20 g/100cfm/d 1.8 gpd 678 20. RETURN DUCT HEAT LOSS 0 Loss factor 0.00 x Line 16 Loss 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 4165 Wfl ht50ft Right -Suite Commeroia15.0.17RSC50S47 - 2004-Nov-0915:12:27 C.Wy Dowments\WrIghtsoR WACIPRO-SOURCE OFFICE-LUNCH.rso Page 3 Right -Suite Commercial Load Calculation WOMEN PRO SOURCE Job: 111612004' Rrojeet Information •-. SOURCE LUNCH/OFFICE, FT. PIERCE, FIL 34945 Zone: WOMEN LWH: 8.0 x 8.0 x 8.0 1. DESIGN CONDITIONS - COOLING ( Jul 1700 ) Dry Bib RH Moisture Range Wet Bib Outdoor Conditions 89 62 15 78 Indoor Conditions --- > 75 50 63 TOD Correction --- > 2 Difference 14 61.4 Mult = 1.0 ] - i - 2. GLAZING SOLAR HEAT GAIN ( Lat = 27.45 ON , Const Wt = M ) Type Orien Shad Tilt %ovr Area SC Shgf Shad Sens n/a 0 n/a 0 0 0.00 0 0.0 0 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens WALL 3 N 64 64 0.137 D 16.5 N D 145 WALL 3 S 64 43 0.137 D 22.8 N D 134 DOOR 3 s 21 21 0.360 13.5 - 102 FLOR 1 - 16 16 0.810 0.0 0 4. INTERNAL HEAT GAIN Sens Latent PEOPLE Activity Total Sensible Latent Schedule ft'/prsn # people Btuh/prsn Btuh/prsn Restroom 50 0 1 210 140 269 179 8to6 0 0 0 0 0 0 0 wnghtsc3ft Right-Sufte Commercial 5.0.17 RSC50847 2004-Nov-0915:12:27 C:UAy Documents\Wrighlsoft HVACIPRO-SOURCE OFFICE-LUNCH.rsc Page 1 11. RETURN DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval WALL 3 N 64 64 0.137 WALL 3 S 64 43 0.137 DOOR 3 s 21 21 0.360 FLOR 1 16 16 0.810 0 2105 2727 ( 70 - 42) = 28 Mult = 1.0 ] — HTD Loss 28.0 246 28.0 165 28.0 212 28.0 363 15. INFILTRATION Loss 695 23 cfm x db Temp Diff 28.0 x 1.10 16. SUBTOTAL HEATING LOAD FOR SPACE 1680 17. SUPPLY DUCT HEAT LOSS 50 Loss factor 0.03 x Line 16 Loss 18. VENTILATION 50 cfm x db Temp Diff 28.0 x 1.10 1540 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 0.0 (Max = 52.0 for 2 pane ) 73 cfm x 3.20 g/100cfm/d = 2.3 gpd 878 20. RETURN DUCT HEAT LOSS 0 Loss factor 0.00 x Line 16 Loss 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 4148 wnghtsoft Right -Suite Commemia15.0.17RSC50847 2004-NOV-0915:12:27 C.Wy DommentslWrightsofl HVACtPRO-SOURCE OFFICE-LUNCH.mc Page 3 Right -Suite Commercial Load Calculation MEN . * PRO SOURCE Job: 111612004 Project Informaltion For: PRO SOURCE LUNCH/OFFICE, FT. PIERCE, FL 34945 Zone: MEN LWH: 26.0 x 11.0 x 8.0 1. DESIGN CONDITIONS - COOLING ( Jul 1700 ) Dry Blb RH Moisture Range Wet ab Outdoor Conditions --- > 89 62 15 78 Indoor Conditions —> 75 50 63 TOD Correction --- > 2 Difference 14 61.4 Mult = 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Lat = 27.45 °N Const Wt = M) , Type Orien Shad Tilt %ovr Area SC Shgf Shad Sens n/a 0 n/a 0 0 0.00 0 0.0 0 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Or Sens WALL 3 N 88 88 0.137 D 16.5 N D 199 WALL 3 E 208 208 0.137 D 32.5 N D 926 WALL 3 S 88 88 0.137 D 22.8 N D 275 WALL 3 W 144 123 0.137 D 24.5 N D 413 DOOR 2 w 21 21 0.360 13.5 102 FLOR 1 - 66 66 0.810 0.0 0 ROOF 1 - 182 182 0.060 R-4 67.5 D 737 4. INTERNAL HEAT GAIN Sens Latent PEOPLE Activity Total Sensible Latent Schedule ft'/prsn # people Btuh/prsn Btuh/prsn Restroom 50 0 6 210 140 1201 801 8to6 0 0 0 0 0 0 0 wnghtsc3ft Right -Suite Commerd1815.C.17 RSC50847 2004-Nov-0915:12:27 C:VvTy Oocuments=dghtsofl HVACtPRO-SOURCE OFFICE-LUNCH.mc Page 1 LIGHTS Type Total Factor Space Schedule W/ft2 W W Btuh/W fract Fluorescent 2.00 0 572 4.10 1.0 2345 8to6 Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 PLUG LOADS / APPLIANCES Application Usage Total Sensible Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6 0.7 0 1.00 200 3 0 683 0 #/ft2 # 0.0 0 1.00 0 0 0 0 0 #/ft' # 0.0 b 1.00 0 0 0 0 0 #/ft2 # 0.0 0 1.00 0 0 0 0 0 #/fr # 0.0 0 1.00 0 0 0 0 0 #/ftz # 0.0 0 1.00 0 0 0 0 0 MOTORS Power (hp) Load Total Sensible Schedule #/ft2 # factor Btuh 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 5. INFILTRATION Sens Latent 25 cfm -> x db Temp Diff 13.5 x 1.10 375 -> x Moist. Diff 61.4 x 0.69 1072 6. SUBTOTAL COOLING LOAD FOR SPACE 7256 1873 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 218 S. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 7474 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 7474) / (1.10 x 20.0 ) = 340 Actual Cooling Fan > = 487 9. VENTILATION 0 cfm -> x db Temp Diff 13.5 x 1.10 0 -> x Moist. Diff 61.4 x 0.69 0 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Lights Total power ( W) 0 2345 RA Roof Load from Line 3 (+) 0 RA Ceiling Load Credit from Line 3 (-) 0 wrlghtsoft Right -Suite Commercial5.0.17RSC50S47 2004-Nov-0915:12:27 C:Wy Documents\Waghtsoft HVACIPRO-SOURCE OFFICE-LUNCH.rsc Page 2 11. RETURN DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE 7474 1873 Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 Mult = 1.0 ] - 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss WALL 3 N 88 88 0.137 28.0 338 WALL 3 E 208 208 0.137 28.0 798 WALL 3 S 88 88 0.137 28.0 338 WALL 3 W 144 123 0.137 28.0 472 DOOR 2 w 21 21 0.360 28.0 212 FLOR 1 66 66 0.810 28.0 1497 ROOF 1 182 182 0.060 28.0 306 15. INFILTRATION Loss 43 cfm x db Temp Diff 28.0 x 1.10 1321 16. SUBTOTAL HEATING LOAD FOR SPACE 5280 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 158 18. VENTILATION 0 cfm x db Temp Diff 28.0 x 1.10 0 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 0.0 (Max = 52.0 for 2 pane ) 43 cfm x 3.20 g/100cfm/d = 1.4 gpd 519 20. RETURN DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 5957 wnghtsoft Right -Suite Commemial5.0.17RSC50647 20N-Nowm 15:12:27 C.XMy DooumentsUdghtsofi HVACtPRO-SOURCE OFFICE-LUNCH.mc Page 3 Right -Suite Commercial Load Calculation GENERAL OFFICE PRO SOURCE Job: 11/5/2004 Project Information For. PRO SOURCE -- LUNCH/OFFICE, FT. PIERCE, FL 34945 Zorie GENERAL'OFFICE` LWH: 25.8 x 48.0 x 8.0 1. DESIGN CONDITIONS - COOLING Outdoor Conditions Indoor Conditions TOD Correction Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Shad Tilt GLAZ 1 S N 90 3. TRANSMISSION GAINS (Jul1500) Dry Bib RH Moisture Range Wet Bib 90 59 15 78 75 50 63 0 15 61.4 ( Lat = 27.45 ON , Const Wt = M %ovr Area Sc Shgf Shad — 64 1.00 0 1.0 Type Orien GrArea NtArea GLAZ 1 S 64 64 WALL 2 N 384 384 WALL 2 S 384 299 WALL 2 W 207 207 DOOR 1 s 21 21 FLOR 1 - 122 122 ROOF 1 - 1240 1240 4. INTERNAL HEAT GAIN PEOPLE Activity Schedule Office 8to6 Uval Grp CLTD Shad Clr 1.040 14.5 N - 0.065 D 13.5 N D 0.065 D 15.8 N D 0.065 D 14.5 N D 0.360 14.5 0.810 0.0 0.060 R-4 66.5 D Mult = 1.0 ] — Sens 1832 Sens 965 337 307 195 110 0 4948 Sens Latent Total Sensible Latent ft2/prsn # people Btuh/prsn Btuh/prsn 150 0 8 250 200 2067 1653 0 0 0 0 0 0 0 wnghtsoft Right -Suite Commercial 5.0.17 RSC50847 2004-N0w0915:12:27 'C:1My Dooumems\WrigMsoft HVACIPRO-SOURCE OFFICE -LUNCH.= Page 1 - LIGHTS Type Total Factor Space Schedule W/ft' W W Btuh/W fract Fluorescent 2.00 0 2480 4.10 1.0 10168 8to6 Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 PLUG LOADS / APPLIANCES Application Usage Total Sensible Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6 0.7 0 1.00 868 3 0 2962 0 #/ft' # 0.0 0 1.00 0 0 0 0 0 #/ft' # 0.0 0 1.00 0 0 0 0 0 #/ft' # 0.0 0 1.00 0 0 0 0 0 #/ft2 # 0.0 0 1.00 0 0 0 0 0 #Ift2 # 0.0 0 1.00 0 0 0 0 0 MOTORS Power (hp) Load Total Sensible Schedule #If? # factor Btuh 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 5. INFILTRATION Sens Latent 10 cfm -> x db Temp Diff 16.0 x 1.10 165 -> x Moist. Diff 61.4 x 0.69 425 6. SUBTOTAL COOLING LOAD FOR SPACE 24054 9098 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 722 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6 ) & Drawthru Fan = 24776 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 24776) / (1.10 x 20.0 ) = 1126 Actual Cooling Fan > = 1371 9. VENTILATION 165 cfm -> x db Temp Diff 15.0 x 1.10 2728 -> x Moist. Diff 61.4 x 0.69 7020 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Lights Total power (W) 0 10168 RA Roof Load from Line 3 (+) 0 RA Ceiling Load Credit from Line 3 (-) 0 wnghtsoft Rlght-Suite Commemia15.0.17RSC50947 2004-Nov-0915:12:27 C.Wy Doouments\Wrightsoft WAMPRO-SOURCE OFFICE-LUNCH.rso Page 2 11. RETURN DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain V 12. TOTAL COOLING LOADS ON EQUIPMENT (Btah) 27504 9098 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 Mult = 1.0 ] - 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ 1 S 64 64 1.100 28.0 1971 WALL 2 N 384 384 0.065 28.0 699 WALL 2 S 384 299 0.065 28.0 544 WALL 2 W 207 207 0.065 28.0 376 DOOR 1 s 21 21 0.360 28.0 212 FLOR 1 122 122 0.810 28.0 2763 ROOF 1 1240 1240 0.060 28.0 2083 15. INFILTRATION Loss 70 cfm x db Temp Diff 28.0 x 1.10 2144 16. SUBTOTAL HEATING LOAD FOR SPACE 10792 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 324 18. VENTILATION 165 cfm x db Temp Diff 28.0 x 1.10 5092 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 235 cfm x 1.48 g/100cfm/d = 3.5 gpd 1276 20. RETURN DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 17484 wrrghtsoft Right -Suite Commercial 5.0.17 RSCS0847 2004-Nov-0915:12:27 C:Wy DocumemsWrlghtsoft HVACIPRO-SOURCE OFFICE-LUNCH.me Page 3 Right -Suite Commercial Load Calculation OFFICE 2 PRO SOURCE Job: 111512004 For. PRO SOURCE LUNCH/OFFICE, FT. PIERCE, FL 34945 Zone: OFFICE 2-' LWH: 13.0 x 12.0 x 8.0 1. DESIGN CONDITIONS - COOLING ( Jul 1500 ) Outdoor Conditions Indoor Conditions TOD Correction Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Shad Tilt GLAZ 1 E N 90 GLAZ 1 S N 90 Dry Bib RH Moisture Range Wet Bib 90 59 15 78 75 50 63 0 15 61.4 Mult = 1.0 ] — ( Lat = 27.45 ON Const Wt = M ) %ovr Area Sc Shgf Shad Sens — 24 1.00 0 1.0 1472 — 32 1.00 0 1.0 916. 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ 1 E 24 24 1.040 14.5 N - 362 GLAZ 1 S 32 32 1.040 14.5 N - 483 WALL 1 E 104 80 0.069 D 33.5 N D 185 WALL 1 S 96 64 0.069 D 15.8 N D 70 WALL 1 W 1 1 0.069 D 14.5 N D 1 FLOR 1 - 25 25 0.810 0.0 0 ROOF 1 - 156 156 0.060 R-4 66.5 D 622 4. INTERNAL HEAT GAIN Sens Latent PEOPLE Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 0 1 250 200 260 208 8to6 0 0 0 0 0 0 0 wnghtsoft Right -Suite Commercial5.0.17RSC50847 2004-Nov-0915:12:27 C:1My Documents\WrIghtsoft HVA0PRO-SOURCE OFFICE-LUNCH.mc Page 1 LIGHTS Type Schedule W/ft' W Fluorescent 2.00 0 8to6 Fluorescent 0.00 0 Fluorescent 0.00 0 Fluorescent 0.00 0 PLUG LOADS / APPLIANCES Application Schedule Plug load W/ft' W 8to6 0.7 0 #/ft2 # 0.0 0 #/ft2 # 0.0 0 #/ff # 0.0 0 #/ft2 # 0.0 0 #/ftz # 0.0 0 MOTORS Power (hp) Schedule #/ft' # 0.00 0.0 0 0.00 0.0 0 0.00 0.0 0 Total Factor Space W Btuh/W fract 312 4.10 1.0 1279 0 4.10 1.0 0 0 4.10 1.0 0 0 4.10 1.0 0 Usage Total Sensible Latent Btuh - Btuh 1.00 109 3 0 373 0 1.00 0 0 0. 0 0 1.00 0 0 0 0 0 1.00 0 0 0 0 0 1.00 0 0 0 0 0 1.00 0 0 0 0 0 Load Total Sensible factor Btuh 1.00 0 0 0 1.00 0 0 0 1.00 0 0 0 5. INFILTRATION 0 cfm -> x db Temp Diff 15.0 x 1.10 -> x Moist. Diff 61.4 x 0.69 6. SUBTOTAL COOLING LOAD FOR SPACE 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain S. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 6204) / (1.10 x 20.0 ) = 282 Actual Cooling Fan > = 346 9. VENTILATION 21 cfm -> x db Temp Diff 15.0 x 1.10 -> x Moist. Diff 61.4 x 0.69 Sens Latent 0 0 6023 1091 181 6204 343 883 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Lights Total power (W) 0 1279 RA Roof Load from Line 3 (+) 0 RA Ceiling Load Credit from Line 3 (-) 0 wrightsoft Right-Sufte Commercial 5.0.17 RSC50847 2004-Now0915:12:27 C:1My Documents\Wrightsoft WAVPRO-SOURCE OFFICE -LUNCH.= Page 2 11. RETURN DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 0 ' 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 6547 1091 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 - - 1.0 - Mult = ] 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ 1 E 24 24 1.100 28.0 739 GIAZ 1 S 32 32 1.100 28.0 986 WALL 1 E 104 80 0.069 28.0 155 WALL 1 S 96 64 0.069 28.0 124 WALL 1 W 1 1 0.069 28.0 3 FLOR 1 25 25 0.810 28.0 571 ROOF 1 156 156 0.060 28.0 262 15. INFILTRATION 6 cfm x db Temp Diff 28.0 x 1.10 16. SUBTOTAL HEATING LOAD FOR SPACE 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 18. VENTILATION 21 cfm x db Temp Diff 28.0 x 1.10 19. HUMIDIFICATION - Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 27 cfm x 1.48 g/100cfm/d = 0.4 gpd 20. RETURN DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) wnghtsoft Right -Sane Commemial5.0.17RSC50847 C:IMy Do entslWrightwft HVACIPRO-SOURCE OFFICE -LUNCH.= Loss 192 3031 91 641 147 2004-No 0915:12:27 Page 3 Right -Suite Commercial Load Calculation F OFFICE 3 PRO SOURCE Job: 111512004 Projoct Information For: PRO SOURCE LUNCH/OFFICE, FT. PIERCE, FL 34945 Zone: OFFICE 3 LWH: 13.0 x 12.0 x 8.0 1. DESIGN CONDITIONS - COOLING Outdoor Conditions Indoor Conditions TOD Correction Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Shad Tilt GLAZ 1 E N 90 3. TRANSMISSION GAINS (Jul 1500) Dry Bib RH Moisture 90 59 75 50 0 Range Wet Bib 15 78 63 15 61.4 ( Let = 27.45 'N Const Wt %ovr Area Sc Shgf Shad --- 24 1.00 0 1.0 Type Orien GrArea NtArea GLAZ 1 E 24 24 WALL 1 N 96 96 WALL 1 E 104 80 FLOR 1 - 25 25 ROOF 1 - 156 156 4. INTERNAL HEAT GAIN PEOPLE Activity Schedule ft2/prsn. Office 150 8to6 0 --[ Muit = 1.0 ] — = M) Sens 1472 Uval Grp CLTD Shad Clr Sens 1.040 14.5 N - 362 0.069 D 13.5 N D 89 0.069 D 33.5 N D 185 0.810 0.0 0 0.060 R-4 66.5 D 622 Sens Latent Total Sensible Latent # people Btuh/prsn Btuh/prsn 0 1 250 200 260 208 0 0 0 0 0 0 wnghtsoft RightSute Commetciai5.9.17RSC50847 2004-No"915:12:27 CAMy DowmentslWtightsoft HUACIPRO-SOURCE OFFICE-LUNCH.mc Page 1 .,t LIGHTS Type Total Factor Space Schedule W/ft' W W Btuh/W Tract Fluorescent 2.00 0 312 4.10 1.0 1279 8to6 Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 -- PLUG LOADS / APPLIANCES Application Usage Total Sensible Latent Schedule Btuh Btuh Plug load W/ft' W 8to6 0.7 0 1.00 109 3 0 373 0 #/ft2 # 0.0 0 1.00 0 0 0 0 0 #Ift' # 0.0 0 1.00 0 0 0 0 0 #/ft' # 0.0 0 1.00 0 0 0 0 0 #fft2 # 0.0 0 1.00 0 0 0 0 0 #/ftz # 0.0 0 1.00 0 0 0 0 0 MOTORS Power (hp) Load Total Sensible Schedule #/ftz # factor Btuh 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 5. INFILTRATION Sens Latent 0 cfm -> x db Temp Diff 15.0 x 1.10 0 , -> x Moist. Diff 61.4 x 0.69 0 6. SUBTOTAL COOLING LOAD FOR SPACE 4643 1091 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 139 8. COOLING FAN SIZING Sum of Duct Gain (7) Line (6) & Drawthru Fan = 4782 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 4782) / (1.10 x 20.0 ) = 217 Actual Cooling Fan > = 283 9. VENTILATION 21 cfm -> x db Temp Diff 15.0 x 1.10 343 -> x Moist. Diff 61.4 x 0.69 883 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Lights Total power (W) 0 1279 RA Roof Load from Line 3 (+) 0 RA Ceiling Load Credit from Line 3 (-) 0 wnghtsoft Right -Suite commercia15.0.17 RSC50847 2004-Nav-0915:12:27 C:UNy DowmentslWrightsoft HVACIPRO-SOURCE OFFICE -LUNCH.= Page 2 'w 11. RETURN DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 5125 1091 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE _ Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 Mult = 1.0 ] — 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ 1 E 24 24 1.100 28.0 739 WALL 1 N 96 96 0.069 28.0 185 WALL 1 E 104 80 0.069 28.0 155 FLOR 1 25 25 0.810 28.0 567 ROOF 1 156 156 0.060 28.0 262 15. INFILTRATION Loss 6 cfm x db Temp Diff 28.0 x 1.10 192 - 16. SUBTOTAL HEATING LOAD FOR SPACE 2101 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 63 18. VENTH ATION 21 cfm x db Temp Diff 28.0 x 1.10 641 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 27 cfm x 1.48 gl100cfmld = 0.4 gpd 147 20. RETURN DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 2951 wrightsoft Right -Suite Commercia15.0.17RSC50847 2004-Nov-0915:12:27 C:1My Documents\Wdghtsofl HVACTRO-SOURCE OFFICE-LUNCH.mc Page 3 h Right -Suite Commercial Load Calculation LUNCH RM PRO SOURCE Job: 111612004 ProjkA Information For: PRO SOURCE — LUNCH/OFFICE, FT. PIERCE, FL 34945 Zone: LUNCH RM LWH: 26.0 x 32.0 x 8.0 1. DESIGN CONDITIONS - COOLING ( Jul 1700 ) Dry Bib RH Moisture Range Wet Bib Outdoor Conditions 89 62 15 78 Indoor Conditions 75 50 63 TOD Correction 2 Difference 14 61.4 Mult = 1.0 ] - - 2. GLAZING SOLAR HEAT GAIN ( Lat = 27.45 ON . , Const Wt = M ) Type Orien Shad Tilt %ovr Area SC Shgf Shad Sens GLAZ 1 S N 90 — 12 1.00 0 1.0 266 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ 1 S 12 12 1.040 13.5 N - 168 WALL 3 N 256 256 0.137 D 16.5 N D 579 WALL 3 E 144 144 0.137 D 32.5 N D 641 WALL 3 S 256 223 0.137 D 22.8 N D 696 DOOR 4 s 21 21 0.360 13.5 102 FLOR 1 82 82 0.810 0.0 0 ROOF 1 - 5 5 0.060 R-4 67.5 D 22 4. INTERNAL HEAT GAIN Sens Latent PEOPLE Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Restaurant 75 ' 0 11 275 275 3051 3051 8tO6 0 wrrghtsc3ft Right-SuRe Commercial '5.0.17 RSCS0847 2004.NOv 0915:12:27 C.Wy Doauments\Wrightsofl HVACIPRO-SOURCE OFFICE-LUNCH.tso Page 1 . .� LIGHTS Type Total Factor Space Schedule Wff W W Btuh/W Tract Fluorescent 2.00 0 1664 4.10 1.0 6822 8to6 Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 Fluorescent 0.00 0 0 4.10 1.0 0 - PLUG LOADS / APPLIANCES Application Usage Total Sensible Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6 0.7 0 1.00 582 3 0 1987 0 #/ft' # 0.0 0 1.00 0 0 0 0 0 W # 0.0 0 1.00 0 0 0 0 0 #/ftz # 0.0 0 1.00 0 0 0 0 0 #/ft' # 0.0 0 1.00 0 0 0 0 0 #/ft2 # 0.0 0 1.00 0 0 0 0 0 MOTORS Power (hp) Load Total Sensible Schedule #/ft' # factor Btuh 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 0.00 0.0 0 1.00 0 0 0 5. INFILTRATION Sens Latent 10 cfm -> x db Temp Diff 13.5 x 1.10 149 -> x Moist. Diff 61.4 x 0.69 425 6. SUBTOTAL COOLING LOAD FOR SPACE 14483 12896 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 434 S. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 14917 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 14917) / (1.10 x 20.0 ) = 678 Actual Cooling Fan > = 960 9. VENTILATION 222 cfm -> x db Temp Diff 13.5 x 1.10 3295 - -> x Moist. Diff 61.4 x 0.69 9421 10. RETURN AIR LOAD FROM LIGHTING AND ROOF Lights Total power (W) 0 6822 RA Roof Load from Line 3 (+) 0 RA Ceiling Load Credit from Line 3 (-) 0 wnghtsoft RightSuite Commercial5.0.17RSC50847 2004-Nov-0915:12:27 C-.Wy D=mentslWAghtsoR HVACIPRO-SOURCE OFFICE-LUNCH.mc Page 2 11. RETURN DUCT HEAT GAIN Gain factor 0.00 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 18212 12896 SPACE BEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 Mult = 1.0 ] - 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ 1 S 12 12 1.100 28.0 370 WALL 3 N 256 256 0.137 28.0 982 WALL 3 E 144 144 0.137 28.0 552 WALL 3 S 256 223 0.137 28.0 855 DOOR 4 s 21 21 0.360 28.0 212 FLOR 1 82 82 0.810 28.0 1860 ROOF 1 5 5 0.060 28.0 9 15. INFILTRATION Loss 53 cfm x db Temp Diff 28.0 x 1.10 1641 16. SUBTOTAL HEATING LOAD FOR SPACE 6481 17. SUPPLY DUCT BEAT LOSS Loss factor 0.03 x Line 16 Loss 194 18. VENTILATION 222 cfm x db Temp Diff 28.0 x 1.10 6833 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 275 cfm x 1.48 g/100cfm/d = 4.1 gpd 1494 20. RETURN DUCT HEAT LOSS Loss factor 0.00 x Line 16 Loss 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btah) 15003 wrrghtsoft Right -Suite Commercial 5.0.17 RSC50847 2004-Nov-0915:12:27 C:Wiy DowmemslWrlghtsofl WACTRO-SOURCE OFFICE-LUNCH.m Page 3 ®STEPHEN A. BROCK ARCHITECTS, INC. 4189 Elm Avenue Palm Beach Gardens, FL 33410 Office (561) 622-4480 • Fax (561) 630-0784 e-mail: SABAI@bellsouth.net • License AR0006492 December 20, 2004 • Mr. Wihiam Hatcher Plans Review Agent St. Lucie County Building Dept. 2300 Virginia Avenue Fort Pierce, Florida 34982 Re: Builder's First Source Permit#124101909 Dear Mr. Hatcher: Thank you for your time in preparing plans review comments for this project. We appreciate the task tha, you undertake each day. As per the comments, we have the following responses: 1. 2rdlevel office would require elevator to meetflorida accessibility code 11-4.1.2. Code section 11-4.1.3 (5) exception 41 allows that elevators are not required if the floor area is less than 3,000 sq. feet unless the building is a shopping mall, shopping center, or the office of a health care provider. This facility meets the requirements of this exception. 2. . Fire sprinkler plans -table 500-factory industrial type IV unprotected. Building "A" will have a sprinkler system and the plans are being prepared by the contractor. Building "C" is factory industrial with an allowable area of 21,000 sq. feet unsprinkled. Area modifications allow 100% increase or a 21,000 sq. foot increase. The total allowable is 42,000 s.f and the total shown in the plans is 41,500 s.f. 3. Travel distance length to exit — table 1004 Florida Building Code — manufacturer travel distance to swing door warehouse from offices. The allowable distance of travel in the manufacturing area is 250 feet in a sprinkler protected building. The distance to a required exit is less than the maximum from any point. 4. Exits 2 d level minimum number for egress code 1004.2.2 per story 2. The drawings have been modified to provide a maximum distance of 75 feet to a single exit per section 1004.1.2 of the Florida Building Code. We believe that these responses will meet with your approval. Should you have any further questions or concerns regarding our building permit application, please do not hesitate to call on ct Stephen A. Brock Architects, Inc.