:STAR BUILDING SYSTEMS
RECEIVED
NOV 0 3 2004
MARK CONSTRUCTION CO.
October 28, 2004
MARK CONSTRUCTION
421 GOLD MEDAL COURT
LONGWOOD, FL 32750
Gentlemen:
STAR BUILDING SYSTEMS
P. O. Box 94910
Oklahoma City, OK 73143-491 O
405-636-2010
FAX 405-636-2419
Subject: COMMERCIAL PROPERTY ASSOCIATES
FORT PIERCE, FL
(A) SMT 160'-0" x 250'-0" x 20'-0" Is
10@25'-0", Bay Spacings
Star Job Number 10-B-96509 (REVISED)
This is to certify that materials for the subject structure have been designed in accordance with
the order documents, specifically as shown per the attached Engineering Design Criteria
Sheet.
Aspects of code compliance as related to use or occupancy, such as sprinkler requirements,
are not addressed by these documents.
The materials for this building have been designed in general accordance with the 9th edition,
AISC Steel Construction Manual and 1996 AISI Cold Formed Steel Design Manual with 1999
addendum.
Star Building Systems is certified by AISC in Category MB. These structural components have
been designed at the Oklahoma City, OK, facility and will be fabricated at one or more of the
following AISC certified locations: Monticello, IA; Lockeford, CA; Elizabethton, TN; Columbus,
MS; or Rocky Mount, NC.
These materials, when properly erected on an adequate foundation in accordance with the
erection drawings as supplied and using the components as furnished, will meet the attached
loading requirements without exceeding the allowable working stress.
This certification does not cover field modifications or the design of materials not furnished by
Star Building Systems.
The attached calculations are to remain with and form part of this Letter of Certification. This
letter voids and supersedes the previous.Letter of Certification, dated September 16, 2004.
The undersigned is not the engineer of record for the overall project.
ordially, f, n
S� AR BUILD YSTI
M terials for e I Build
olbertson C o oral
V
Dennis P. Watson, P.E.
Director of Engineering
Florida #17978
Ltd 8600 South Interstate 35, Oklahoma City, OK 73149
GFNhpiC
o I 9i
. �h'"OM'M'0•
Star Building Systems
Engineering Services
Design Criteria
Job Number: - 10-B-96509
Engineer: vJ,
Building Code _ Florida 2001'---
Building End Use Commercial
Classification of Building Standard
Impact Loads,
'Dead Load (Star material)
(Average weight of panels, purlins
Collateral Loads
Sprinkler -
Ceiling (non -plaster)
Lights
Other
Fixed Service Equipment
Designed Roof Live Load
Column Lines
Ground Snow Load
Wind Speed
Importance Factor, Wind
Wind Exposure
Building Designed
Internal Pressure Coefficient
None '
4.0 psf
and frames)
5.0 psf (total)
0.0 psf
0.0 psf
0.0 psf
5.0 psf
None
12.0 psf (Purlins)
12.0 psf (Frames)
None
130.0 mph
1
B
Open
+/- 0.00 (GCpi)
10/28/2004
Revision 5 1 of 24 vJ
"Bracing size" as noted on.Engine_ering documents and Erection
drawings denotes thread diameter for rod bracing and wire strand
cable diameter for wire strand cable bracing. -
All bolted joints with A325 Type 1 bolts are specified as
snug -tightened joints in accordance with the "Specification for
Structural Joints Using ASTM A325 or A490 Bolts, June'23, 2000".
Pretensioning methods, including turn -of -nut and'calibrated wrench
,are NOT required.
The materials supplied by Star Building Systems are designed -for
building(s) A & B to be classified as open or enclosed, per the
specified building code. If all walls are enclosed in the future, the
material shall attach to Star's framing to adequately transfer all
loads to the main framing system (rigid frames and rodbracing).
The maximum weight of any future wall enclosure material is 3 psf.
Any future construction that does not leave the building classified
as open or enclosed, per the specified building code, or exceeds
a weight of 3 psf, could void warranties and certifications as they
apply to the material supplied by Star.
Product approval numbers for the State of Florida, Department of
Community Affairs per Product Rule 9B-72:
1. Panel Walls
FL3093.1 26 Ga'. DuraRib walls
FL3093.2 29 Ga. DuraRib walls
FL3093.3 26 Ga. Starmark walls
FL3093.9 29 Ga. Starmark walls
3. Roofing Products
FL3088.1 26 Ga. DuraRib roofs
FL3088.2 29 Ga.. DuraRib roofs
FL3088.3 29 Ga. Starshield roofs
FL3088.9 22 Ga. Starshield roofs
7. Structural Components
FL3099.1 Structural Zee Sections
FL3099.2 Structural Cee Sections
10/28/2004
Revision 5 2 of 24' vi
The material supplied by
Star,has been designed with.the
following minimum deflection criteria: The actual
deflection
may be less depending'= -on
actual -load and -actual member length.
'
The frame sidesway for wind=loading is based on a
10'year
mean occurrence
wind interval.
Roof Purlins
- -
- .-Wall .Panels
-
Live
..t / 150
'Total` Wind
L F
90 -
Snow
L /'150
-Wall Girts
- -
Wind -
L / 120
Total Wind
L /
90
Total Gravity_L
/ 150
Endwall Columns
Total Uplift
L / 120
Total Wind
L /
120
• Frame/Portal Frame Sidesway.
Roof Rafters
_
.. Frame Live
H�/,
90
Live
L /._180
Frame Snow
H /
90
Snow
L / 180
Frame Wind
H /
_
50 '
Wind—L'
150
-Frame Seismic
H /
50
Total Gravity_L
/ 180
Frame Crane
H'./.
0
Total Uplift_L
/ 150
Frame Total Wind
H /
50
'
Frame Total Seismic
H /
50
Roof Panels
Frame Total Gravity--H
/
90
Live
•L / 150
Portal Total Wind
/
60
Snow
L_/ 150
—H
Portal Total Seibmic_H /
50
Total Uplift_L
/ 120
All deflection
and sidesway limits shown are at service
loads unless
indicated otherwise.
10/28/2004
Revision 5
3 of 24
vJ
Star Building
Systems, OKC, OK
User: vjoseph
Message Program - Version 2.3
Job Number: 96509A
Design Summary
Report run01
Date:
10/25/04
Manufacturing
Plant - Elizabethton, TN
Start Time:
10:17:21
J:\Active\ENGO-B-96509\OPEN02-vjoseph\Bldg-A\run01\
,M•. A I N.
B U_ I L. D ~I N G D
E S I G N
S U M M A R Y R
E P O R T
DATA
.BUILDING
Live Load:
12.00 psf
SMT 16010 x
250 �'0' x 2Q'b., 1.:''L2
Tributary Check:
YES
Bays: 10@2510
Building Code:
Florida 2001
Roof.'Snow Load:
0.00 psf
Wind Exposure Category: B
Wind Load:
130.00 mph
Seismic
Zone: N
Dead Load:
1.90 psf
Collateral Load:
5.00 psf
-------------
ROOF PLANE.-------
------------------------
RPA
---------
-------
PANEL
: SDR 26GA GALM (DURA-RIB)
PURLIN SPACING
: 2@4.4044 14@510 1.1912
Bay
Length Member Size
Brace
L Lap R Lap
Bear
#
1(ft) Identification
Locations
Exten Exten
Stiff
-----'----------------------------------------------------------------
1
25.000 8.5Z88 PURLIN/
None
S 0.000 3.188
C None
2'
25.000 8.5Z72 PURLIN
None
C 2.583 2.583
C None
3-
25.000 8.5Z72 PURLIN
None
C 2.583 2.583
C None
4
25.000 8.5Z72 PURLIN
None
C 2.583 2.583
C None
5
25.000 8.5Z72 PURLIN
None
C 2.583 2.583
C None
6
25.000 8.5Z72 PURLIN
None
C 2.583 2.583
C None
7
25.000 8.5Z72 PURLIN
None
C 2.583 2.583
C None
8
25.000 8.5Z72 PURLIN
None
C 2.583 2.583
C None
9
25.000 8.5Z72 PURLIN
None -
C 2.583 2.583
C None
10
25.000 8.5Z88 PURLIN
None
C 3.188 0.000
S None
Area with Sub -Framing
Bay
Width Start
Length
Number and size of
Edge Purlin
#
(ft-in) (ft)
(ft)
between Main Purlins
---------------------------------------------------------------------
1 &10
1212 0.00
8.81
1 8.5Z57 PURLIN
Note(s) .
1) Area with Sub -Framing distances are measured from sidewall
steel line and are additive.
2) Use 2-1/2 x 2-1/2 x 3/16 angle sub -framing for support.
Purlin Anchorage Hdwe @ 9,17 @ Frame Lines:1-11
10/28/2004
Revision 5
4of24
vi
Star Building Systems, OKC, OK.
User:
vjoseph
Message Program -
version 2.,3`, "'
Job Number: 96509P`
Design Summary Report
1 . riin0i
Date: 10/25/04
Manufactuting Plant =
Elizalethton, TN
Start
Time: 10:17:21 '
J:\Active\ENGR.-B=96509'\OPEN02-vjoseph\Bldg-A\run01\
---------------------------------------------------------
ROOF PLANE-----y,� RPC u
PANEL "' :' SDR 26GA`. GALM (DURA-RIB)
PURLIN SPACING 2@4.4044.14@5'0 1.1912
Bay Length-"
Member Size
Brace
L Lap
R Lap
Bear _.
4. (ft)-
Identification
Locations
Exten
Exten
Stiff
---------------------_------------------------------------------------
1 25.000
.8.5Z88 PURLIN .None
S
0.000
3.188
C None
2 -r 25.000
8.5Z72 PURLIN
'None
C
2.583
2.583
C None
- 3- 25.000
8.5Z72 PURLIN
None
C
2.583
2.583
C None
4 25.000
8:SZ72 PURLIN
None
C
2.583
2.583
C None
5 25.000."
8.5Z72 PURLIN
None
C
2.583
2.583
C None
.6 25:000
8.5Z72 PURLIN
None
C
2.583
2.583
C None
7 25.000
8.5Z72 PURLIN
None
C
2.583
2.583
C None
8 25.000
8.5Z72 ••PURLIN
None
C
2.583
2.583
C None
9 25.000
8.5Z72 PURLIN
None
C
2.583
2.583
C None
- 10 25.060
8.5Z88 PURLIN
None
C
3.188
0.000
S None
Area with Sub -Framing
Bay
Width Start
Length
Number
and
size of Edge Purlin
#
---------------------------------------------------------------------
(ft-in) (ft)
(ft)
between
Main Purlins
1 &10
1212 0.00
8.81
1
8.5Z57
PURLIN
Notes) .
1) Area with Sub -Framing distances are measured from sidewall
steel line and are additive.
2) Use 2-1/2 x 2-1/2 x 3/16 angle sub -framing for support.
Purlin Anchorage Hdwe @ 9,17 @ Frame Lines:l-il
STRUTS PLANES SWA ----
STRUTS PLANES SWC ----
SIZE AND LAPS SAME AS ROOF PURLINS @ Bays 1 - 10
SIZE AND LAPS SAME AS ROOF PURLINS @ Bays 1 - 10
10/28/2004
Revision 5
5 of 24
vi
Star Building Systems, OKC, OK User: vjoseph
Message Program - Version 2.3 Job Number: 96509A
Design Summary Report run01 Date: 10/25/04
Manufacturing Plant - Elizabethton, TN Start Time: 10:17:21
J:\Active\ENGO-B-96509\OPEN02-vjoseph\Bldg-A\run01\
-------------------------------------------------------------------------------
BRACING ---- Roof: 5 bays rods
Plane SWA :Portal Frame
Plane SWC :Portal Frame
Plane EWB :End Frame
Plane EWD :End Frame
SIDEWALL PLANE SWA -- ( .8.50011 Inset columns )
"OPEN TO REMAIN OPEN"
SIDEWALL PLANE SWC -- (- 8.500" Inset columns )
"OPEN TO REMAIN OPEN"
ENDWALL PLANE EWB ---- Non -Expandable Frame (SMT )
"OPEN TO REMAIN OPEN"
ENDWALL PLANE EWD ---- Non -Expandable Frame (SMT
"OPEN TO REMAIN OPEN"
FRAMES ----- Type Span Live Wind Eave Trib
SMT 160.000 12.00/130.00 20.00/ 25.00
SMT 160.000 12.00/130.00 20.00/ 18.08
Frame Lines
2-10
1, 11
10/28/2004
Revision 5 6 of 24 vi
Star Building Systems,
OKC, OK
User: vjoseph
Message Program -
Version 2.3-268
Job Number:
96509A
Design Summary Report
run01
Date:
10/25/04
Manufacturing Plant -
Elizabethton, TN
Start Time:
10:17:21
J:\Active\ENG®-B-96509\OPEN02-vjoseph\Bldg-A\run01\
-------------------------------------------------------------------------------
A-SWA-CF01
C A N O P Y D E
S I G N
S U
M M A R Y R E P
O R T
BUILDING DATA
Live Load: 12.00
psf
CANOPY 1510 x 26010 x
20'0 1.:12
Tributary Check: Yes
Bays: 3010 8@2510 3010
Building Code: Florida
2001
Roof
Snow Load: 0.00
psf
Wind Exposure Category: B
Wind Load: 130.00
mph
Dead Load: 3.25
psf
--------------------------------------------------------------------------------
PANELS ----- Roof: SDR
26GA GALM
(DURA-RIB)
PURLINS ---- Spacings
:316 2@419 210
Bay Length
Member Size
Brace
L
Lap R Lap Bear
# (ft)
Identification
Locations
Exten Exten Stiff
---------------------------------------------------------------------
1 30.000
8.5Z88 PURLIN
None
S
0.000 3.188 C
None
2 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C
None
3 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C
None
4 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C
None
5 25.000
8.SZ72 PURLIN
None
C
2.583 2.583 C
None
6 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C
None
7 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C
None
8 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C
None
9 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C
None
10 30.000
8.5Z88 PURLIN
None
C
3.188 0.000 S
None
EAVE STRUTS ---- 8.5E92
E.S. @ Bays
1 - 10
RAFTER ---- Built-up
BOSS
Starting Ending Web Out Flange Inner Flange
Length Web Depth Web Depth Thickness Width Thickness Width Thickness
(feet) (inches) (inches) (inches) (in.) (in.) (in.) (in.)
---------------------------------------------------------------------
15.052 18.934 8.000 0.2500 8.00 x 0.2500 8.00 x 0.2500
With 212I Type End Connection and 8.000 x 0.625 (in) Plate.
Starting Ending Web Out Flange Inner Flange
Length Web Depth Web Depth Thickness Width Thickness Width Thickness
(feet) (inches) (inches) (inches) (in.) (in.) (in.) (in.)
---------------------------------------------------------------------
0.708 19.643 18.934 0.1250 6.00 x 0.3750 6.00 x 0.3750
With 8.00 x 20.25 x 0.6250 (in) Boss End Plate.
10/28/2004
Revision 5
7of24
vi
Star Building Systems,
OKC, OK
User: vjoseph Page: 6
Message Program -
Version 2.3-268
Job Number: 96509A
Design Summary Report
run01
Date: 10/25/04
Manufacturing Plant -
Elizabethton, TN
Start Time: 10:17:21
J:\Active\ENG®-B-96509\OPEN02-vjoseph\Bldg-A\run01\
-------------------------------------------------------------------------------
A-SWC-CF01
C A N O P Y D E
S I G N
S U
M M A R Y R E P 0 R T
BUILDING DATA
Live Load: 12.00 psf.
CANOPY 1510 x 26010 x
2010 1.:12
Tributary Check: Yes
Bays: 3010 8@2510 3010
Building Code: Florida
2001
Roof Snow Load: 0.00 psf
Wind Exposure Category: B
Wind Load: 130.00 mph
Dead Load: 2.24 psf
--------------------------------------------------------------------------------
PANELS ----- Roof: SDR
26GA GALM
(DURA-RIB)
PURLINS ---- Spacings
:316 2@419 210
Bay Length
Member Size
Brace
L
Lap R Lap Bear
# (ft)
Identification
Locations
Exten Exten Stiff
---------------------------------------------------------------------
1 30.000
8.5Z88 PURLIN
None
S
0.000 3.188 C None
2 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C None
3 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C None
4 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C None
5 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C None
6 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C None
7 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C None
8 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C None
9 25.000
8.5Z72 PURLIN
None
C
2.583 2.583 C None
10. 30.000
8.5Z88 PURLIN
None
C
3.188 0.000 S None
EAVE STRUTS ---- 8.5E92
E.S. @ Bays
1 - 10
RAFTER ---- Built-up
BOSS
Starting Ending Web Out Flange Inner Flange
Length Web Depth Web Depth Thickness Width Thickness Width Thickness
(feet) (inches) (inches) (inches) (in.) (in.) (in.) (in.)
---------------------------------------------------------------------
15.052 18.934 8.000 0.2500 8.00 x 0.2500 8.00 x 0.2500
With 2I2I Type End Connection and 8.000 x 0.625 (in) Plate.
Starting Ending Web Out Flange Inner Flange
Length Web Depth Web Depth Thickness Width Thickness Width Thickness
(feet) (inches) (inches) (inches) (in.) (in.) (in.) (in.)
---------------------------------------------------------------------
0.708 19.643 18.934 0.1250 6.00 x 0.3750 6.00 x 0.3750
With 8.00 x 20.25 x 0.6250 (in) Boss End Plate.
10/28/2004
Revision 5 8 of 24 vi
Strut
keys x=double Z,
xx=triple Z, o=pipe
Builder i
3MS -11VM3QIS
MARK CONSTRUCTION
0 ,06Z
Job Noi 96509A run01
Version, OPEN02-vjoseph
0 ,se u,sd 0 ,52 0 ,s2ll 0 ,52 O ,S2 u,sd
0
,SZ 0 Sd 0 ,S
Date Mon Oct 25 10, 171 22 2004
2,T
I I
I
z,T
N
j
I I
I
I I I
I
15S0 SJUct.
1 '
2m
2m
2m
20
20
O rp
0
0
N �
1
O
O
2
O
_
O
O W
O
3
W
O
W
=
0
Jo
�o o
o-
2m
2m
2m
20
2m
15' 0 Struct,
F
P
0
Note: Provide 5-7-5 screw pattern
1, 2
1' 2
with standard lap fasteners
Owner
MARK
CONSTRUCTION
1
4
FORT
PIERCE FL 34945
250'0
SIDEWALL SWA
10/28/2004
RevmSion
9 0f
Star Building Systems
FRAME DESCRIPTION:
USER NAME:vjoseph
DATE:10/25/04
TIME:11:24:04 PAGE: 1-1
8600 S. I-35, Oklahoma City, OK 73149 Smt 160./20./25. 12./130./0.
JOB
NAME:96509A
FILE:fra2thrul0.fra
DESIGN AND ESTIMATION INFORMATION
FRAME ID #01 LOCATION: frame lines 2-10
STANDARD NOTES:
WEIGHT: 6881 lbs
DETAIL FILE: \ENG\30-B-96509\OPEN02-vjoseph\Bldg-A\Drftg\xO1L
(1) All sectional dimensions are in
inches.
YIELD STRENGTH(ksi) - PLATE:50,
PIPE:42, TUBE:46, W.F.:50, FLG BRC:50, BOLTS:A325
SNUG TIGHT
(2) All Flange
lengths are measured
along outer flange.
PURLINS(horz, from save) :8.5°-Z
204'-4 7/811,14®5'
GISTS (vert. from floor):8.5"-Z
(BYPASS)
CONNECTION DETAILS
Location
1
2
3
4
5
6
7
8
9
10
Web Dep.
8.0
34.0
N/A
30.0
25.5
25.5
25.5
40.0
6.625
6.625
Type
BASE
HORZ STP
CAP (EXT)
3E/2E
SPLICE
4E/3E
SPLICE
4E/22
BASE
CAP/STF
Plate (DN)
8.0X0.375
3.75X0.5
8.OXO.25
8. OX0.5
N/A
6.0X0.5
N/A
6.0X0. 625
8. OXO.625
8.OXO.375
Plate(UP)
N/A
N/A
N/A
6.OXO.5
N/A
6.0X0.5
N/A
6.OXO. 625
N/A
N/A
��QQ
(4)-3/4
N/A
N/A
(10)-3/4
N/A
(14)-3/4
N/A
(12)-3/4
(4)-3/4
(4)-1/2
Rev(s)on
vJ
l U Oi Z4
Star Building Systems
FRAME DESCRIPTION: USER
NAME:vjoseph
DATE:10/25/04
TIME:11:24:04 , PAGE: 1-2
8600 S. I-35, Oklahoma City, OK 73149
smt 160./20./25. 12./130./0. JOB
NAME:96509A,'.,
FILE:fra2thrul0.fra _
DESIGN AND ESTIMATION INFORMATION
FRAME ID #OS LOCATION: frame lines 2-10
STANDARD NOTES:
WEIGHT: 6881 lbs
DETAIL FILE: \ENG\10-B-96509\OPEN02-vjoseph\Bldg-A\Drftg\xO1R
(1) All sectional
dimensions are in
inches.
YIELD STRENGTH(ksi) - PLATE:50,
PIPE:42, TUBE:46, W.F.:50, FLG BRC:50, BOLTS:A325 SNUG TIGHT
(2) All Flange
lengths are measured
along outer flange.
PURLINS(horz. from save) :8.5"-Z
2@4'-4 7/6",14®5'
GIRTS (Vert. from floor):8.5"-Z
(BYPASS)
I
M1MCPTON nrTATLB :
Location
1
1 2
3
4
5
6
7
B
9
10
Web Dep.
8.0
34.0
N/A
30.0
25.5
25.5
25.5
40.0
6.625
6.625
Type
BASE
HORZ STF
CAP (EXT)
3E/2E
SPLICE
4E/3E
SPLICE
4E/2I
BASE
CAP/STF
Plate(DN)
8.OXO.375
3.75X0.5
8.0X0.25
8.OXO. 5
N/A
6. OXO.5
N/A
6. OXO. 625
B. 0XO.625
B. OXO.375
Plate(UP)
N/A
N/A
N/A
6. OXO.5
N/A
6. OXO.5
N/A
6. OXO. 625
N/A
N/A
Bo'MM
0043/4
N/A
N/A
(10)-3/4
N/A
(14)-3/4
N/A
(12)-3/4
(4)-3/4
(4)-1/2
Revision
0
12
12
' E.H.
VJ
c
Star Building Systems FRAME DESCRIPTION: USER NAME:vjoseph DATS:10/25/04 PAGE: 1-3
8600 S. I-35, Oklahoma City, OK 73149 smt 160./20./25. 12./130./0 JOB NAME:96509A FILB:fra2thrulO.fra
SUPPORT REACTIONS FOR EACH LOAD GROUP PRAMS ID #01 LOCATION:frame lines 2-10
NOTE: All reactions are in kips and-kip-ft. ..� TIME:11:24:04
REACTION NOTATIONS
VL
LOAD 'GROUP'REACTION TABLE .
V1
COLUMN
LEFT COLUMN
RIGHT COLUMN
INTERIOR COLUMN 1
BASE PLATE
8.OX9.OXO.375
8.OX9.OXO.375
8.OX14.OXC.625
ANC. BOLTS
(Q -3/4
W -3/4
W -3/4
LOAD GROUP
HL
VL
LL
MR
VR
LR
H1
Vl
L1
_ DL
1.3
4.8
0.0
-l'.3
5.2
0.0
0.0
6.7
0.0
LL
4.7
18.2
0.0
-4.7
18.2
0.0
0.0
24.0
0.0
-COLL
2.8
5.0
0.0
-2.8
5.0
0.0
0.0
10.1
0.0
WL1
-4.9
-26.1
0.0
4.0
-17.4
0.0
0.0
-25.3
0.0
WL2
-4.7
-15.4
0.0
1.8
-21.0
0.0
0.0
-20.2
0.0
WL3
-4.0
-17.4
0.0
4.9
-26.1
0.0
0.0
-25.4
0.0
WL4
-1.8
-21.0
0.0
4.7
-15.4
0.0
0.0
-20.3
0.0
LWB1
-5.4
-17.8
0.0
5.4
-17.8
_v 0.0
0.0
-25.5
0.0
LWB2
-5.4
-17.8
0.0
5.4
-17.8
0.0
0.0
-25.5
0.0
LOAD GROUP
DL
DESCRIPTION
Roof Dead Load
LL
Roof Live Load
COLL
Roof Collateral Load
WL1
Lateral Primary Wind Load
WL2
Lateral Primary Wind Load
WL3
Lateral Primary Wind Load
WL4
Lateral Primary Wind Load
.LWB1
Longitudinal Primary Wind Load [base only]
LWB2
'
Longitudinal Primary Wind Load [base only]
n ,
a
- HR
VR
10/28/2004
Revision 5 12 of 24 vJ
i
Star Building Systems FRAME DESCRIPTION: USER NAME:vjoseph DATE:10/25/04 PAGE: 1-4
8600 S. I-35, Oklahoma City, OK 73149 smt 160./20./25. 12./130./0 J09 NAME:96509A FILE:fra2thru10.fra
MAX. SUPPORT REACTIONS FOR LOAD COMBINATIONS - FRAME_ID #01 LOCATION:frame lines 2-10
NOTES:(1) All reactions are in kips and kip-ft.. TIME:11:24:04- --•
(2) These reactions are from loads determined from the applicable code for Aso design. Seismic loads are limit
state and include magnification factors -when so required by the seismic provisions.•of the applicable code
for ASD� esign. It is the resBonsibility of -the foundation. designer to apply the load factors and load
combinations appropriate for the concrete foundation design
REACTION NOTATIONS
,.. 4
HL
VL
LOAD COMBINATION MAXIMMM REACTION TABLE .
COLUMN
LEFT COLUMN
RIGHT COLUMN
'INTERIOR COLUMN 1
BASE PLATE
8.OX9.OXO.375
8.OX9.OXO.375
8.0X14.9 0.625
ANC. BOLTS
--(4)-3/4
._ (4)-3/4 `
(4)-3/4
LOAD COMB
- RL
, VL' LLB
HR
I VR I LR I
H1
I V1
I L1
GRAVITr LOAD COMBINATION ._ •. _.
1 1 8.91 27.9 ` 0.0 -8.91 28.3 0.0
MIND LOAD CDMB1NATION _
21
6.4
7.6
0.0
-4.2
12.2
O.D
0.0
- 19.6
0.0
12
-4.6
-15.0
0.0
4.6
-14.7
0.0
0.0
-21.5
0.0
19
4.2
11:8
6.0
-6.4
. 8.0
0.0
0.0
19.6
0;0
8
-4.1
-23.2
0.0
3.2
-14.3
0.0
0.0
-21.3
0.0
10
-3.2
-14.61
0.0
4.1
-22.9
0.0
0.0.
-21.4
0.0
LOAD COMBINATION
1
DESCRIPTION. ..
DL +LL +COLL
8
0.6DL
+WL1
10
0.6DL
+WL3
- 12
0.6DL
+LW331
19
DL +0.75LL
_
+COLL +0.75WL2.
21
DL +0.75LL
+COLL +0.75WL4
+
L MR
VR
10/28/2004
Revision 5
13 of 24
vJ
Star Building Systems
w
FRAME DESCRIPTION: USER
NAME:vjoseph' i
DATE:10/25/04
TIME:11:23:53 PAGE: 2-1
8600 S. I-35, Oklahoma City, OK 73149
smt 160./20./18.083 12./130./0. JOB
NAME:96509A
FILE:fra1 11.fra
DESIGN AND ESTIMATION INFORMATION
FRAME ID. H02
-'LOCATION: frame lines 1
STANDARD NOTES:
"
WEIGHT: 5879 'lbe
DETAIL'FILE:
\ENG\10-B-96509\OPEN02-vjoseph\Bldg-A\Drftg\X02L
(1) All sectional dimensions
are in
inches.
YIELD ETRENGTH(ksi) - PLATE:50,
PIPE:42; TUBE:46,
W.F.:50, FLG BRC:50, BOLTS:A325 SNUG TIGHT
(2) All Flange lengths
are measured
along outer flange.
PURLINS(horz. from save) :B.S"-Z
4m2,'-2 7/16",1495'
GIRTS (vent.: from floor):8':5"-Z
(BYPASS)
4
Y
'
G
1
20' E.H.
CONNECTION DETAILS :
Location
1
2
3
4
5
6
7
8
9
10
Web Dep.
8.0
26.0
N/A
25.0
19.5
19.5
19.5
35.0
6.625
6.625
Type
BASE
HORZ STF
CAP (EXT)
3E/2E
SPLICE
4E/3E
SPLICE
4E/2I
EASE
CAP/STF
Plate(DN)
8.0X0.3]5
3.]5%0.3125
a. 0%0. 25
8. 0X0.5
N/A
6.OX0.5
N/A
6. 0%0.5
8. Us.5
8. 0X0.375
Plate(UP)
N/A
N/A
N/A
6. OX0.5
N/A
6.0%0.5
N/A
G. u%0.5
N/A
N/A
1(4)-1/2
AUiRQQ
N/A
(10)-3/4
N/A
(14)-3/4
N/A
(12)-3/4
(4)-3/4
Revision
l4 OT Z4
Star Building Systems FRAME DESCRIPTION: USER NAME:vjoseph DATE:10/25/04 PAGE: 2-3
8600 S. I-35, Oklahoma City, OK 73149 smt 160./20./18.083 12./130 JOB NAME:96509A FILE:fral_ll.fra
MAX. SUPPORT REACTIONS FOR LOAD COMBINATIONS FRAME ID #02 LOCATION:frame lines 1
NOTES:(1) All reactions are in kips and kip-ft. TIME:11:23:53
(2) These reactions are from loads determined from the applicable code for ASD design. Seismic loads are limit
state and include magnification factors when so required by the seismic provisions of the applicable code
for ASD design. It is the responsibility of the foundation designer to apply the load factors and load
REACTION NOTATIONS,
v
HL --
... VL ..
LOAD COMBINATION MAXIMUM REACTIONTABLE
COLUMN _
LEFT COLUMN
RIGHT COLUMN
INTERIOR COLUMN 1
BASS PLATE
B.OX9.OXO.375
S.OX9.OXO.375
8.OX14.OXO.5
ANC. BOLTS
(4)-3/4
(4)-3/4
(4)-3/4
LOAD COMB
` HL
I VL I LL
MR
I VR 'LR
H1
I Vl
I L1
GRAVITY LOAD COMBINATION
1 5,9 21.0 0.0 - -5.91 21.31 0.01 0.01 30.3 0.0
WINO LOAD COMRINATFON
21
4.5
6.3
0.0
-2.6
9.6
0.0
0.0
14.7
0.0
12
-3.0
-10.4
-10.3
0.0
0.0
-15.5
0.0
19
2.6
9.3
6.6
0.0
0.0
14.7
0.0
B
-2.9
-16.4
91.,
-9.9
0.0
0.0
-15.5
0.0
10
-1.8
-10.1
-16.2
0.0
0.0
-15.5
0.0
LOAD COMBINATION
1
DESCRIPTION
DL +LL +COLL
e
0.6DL +WL1
10
0.6DL +WL3
12
0.6DL +LWBI
19
DL +0.75LL +COLL +0.75WL2
21
DL +0.75LL +COLL +0.75WL4
4
MR
VR
10/28/2004
Revision 5 16 of 24 vJ
Star Building Systems FRAME DESCRIPTION: USER NAME:vjoseph DATE:10/25/04 PAGE: 2-4
8600 S. I-35, Oklahoma City, OK 73149 smt 160./20./1B.083 12./130 JOB NAME:96509A PILE:fra1_ll.fra
USSR LOAD SCHEMATICS FRAME ID #02 LOCATION:frame lines 1
NOTE: All user loads are in kips and kip-ft. TR E:11:23:53
(1) DL
0.02 0.02 0.02 0.02
0.99 m m 1.26
'F'o`r Re�`fe-re-n`ce `O:n'I;,y`,
!Iroards shfow�n are `inclad'ed iFn `rea'ctEio:n fiab'.1.,I
10/28/2004
Revision 5 17 of 24 vJ
Star Building Systems
FRAME DESCRIPTION: USER
NAME:vjoseph
DATE:10/25/04
TIME:11:24:13 PAGE: 4-1
8600 S. I-35, Oklahoma City, OX 73149
pf 25./20. main building at planes SWA JOB
NAME:96509A
FILE:pfra.fra
DESIGN AND ESTIMATION INFORMATION
FRAME ID #04
LOCATION: bays
STANDARD NOTES:
WEIGHT: 3667 lbs
DETAIL FILE:
\ENG\10-B-96509\OPEN02-vjoseph\Bldg-A\Drftg\x04L
(1) All sectional dimensions are in
inches.
YIEL➢ STRENGTH(ksi) - PLATE:50,
PIPE:42, TUBE:46,
W.F.:50, FLG BRC:50, BOLTS:A325 SNUG TIGHT
(2) All Flange lengths
are measured
along outer flange.
PURLINS(horz. from save) :0"-Z
GIRTS (vert. from floor): 0"-Z
(4.25^OUTSET)- LEFT COLUMN 0"-Z (4.25"OUTSET)- RIGHT COLUMN
Location
1
2
3
4
5
6
7
e
Web Dep.
14.5
14.5
N/A
27.5
27.5
14.5
14.5
N/A
Type
BASE
HORZ STF
CAP (EXT)
4E/4E
4E/4E
BASE
HORZ STF
CAP (EXT)
Plate(DN)
10.OXO.375
4.75XO.5
10.OXO.5
10.OXO.75 C
10.OXO.75 C
30.OXO.375
4.75XO.5
30.0X0.5
Plate(UP)
N/A
N/A
N/A
0.0XO.625
0.0X0.625
N/A
N/A
N/A
QQ4
(4)-1
N/A
N/A
(16) /4
(16)-3/4
(4)-1
N/A
N/A
10
Rev)s)on o
VJ
Star Building Systems PRAM DESCRIPTION: USER NAM:vjoseph DATE:10/25/04 PAGE: 4-2
8600 S. I-35, Oklahoma City, OK 73149 pf 25./20. main building at p JOB NAM:96509A FILE:pfra.fra
SUPPORT REACTIONS FOR EACH LOAD GROUP FRAM ID #04 LOCATION:bays
NOTE: All reactions are in kips and kip-ft. TIM:11:24:13
HL
WAD GROUP REACTION TABLE
COLUMN
LEFT COLUMN
RIGHT COLUMN
BASE PLATE
10.OX1S.625X0.375
10.OX15.62SX0.375
ANC. BOLTS
W -1
(0 -1
LOAD GROUP
HL
VL
LL
HR
VR
LR
DL
0.1
1.7
0.0
-0,1
1.7
0.0
WL1
-16,3
-27.3
0.0
-17.2
27,3
0.0
LOAD GROUP DESCRIPTION
DL Roof Dead Load
WL1 Lateral Primary Wind Load
10/28/2004
Revision 5 19 of 24 vJ
S't r Building Systems FRAME DESCRIPTION: USER NAME:vjoseph DATE:1O/25/04 PAGE: 4-4
56O0 S. I-35, Oklahoma City, OR 73149 pf 25./20. main building at p JOB NAME:965O9A PILE:pfra.fra
USER LOAD SCHEMATICS FRAME IO #04 LOCATION:baya
NOTE: All user loads are in kips and kip-ft. TIME:11:24:13
[11 WL1
33.44
r
'fF'o:r'Rre:fe`re.n�c'e �O�n �y,
10/28/2004
Revision 5 21 of 24 vJ
STAR
BUILDING
SYSTEMS
STRUCTURAL CANOPY
RAFTER W/BYPASS GIRTS
AT EAVE DETAILS
JOB NO. 10-B-96509
DATE/BY 1012512004 VJ 1
12
1.0
O
O 1
WEB DEPTH 18.93"" 8.0"
TYPE 21121
PLATES 8.Ox0.625
BOLTS 3/4"
PLATE: 50 ft
BOATS.• A325
BRACKET.•
WEB = 0.25"
TOP = 8.0 x0.25"
BOTTOM= 8.0'x0.25"
10/28/2004
STAR PORTAL FRAME SHEET
BUILDING DETAIL (4 AB min) JOB NO. 104 9WW
SYSTEMS Heavy Connection
DATE/BY 0W152W4 V✓
Nears
wnsry
J
,K a-v4• *
FILE PORTAL FRAME COLUMN
HALF PORTAL COLUMN BASE
PLATE WIDTH PLUS 114'
m A 8114-
� O O O
H ElE*L
INITHFLANGE
FLASH AND 7' GIRTS. GIRTS.
INSIDE GIRT FLANGE AT BYPASS GIRTS.
B"MFRAWCO(M
Revision 5 23 of 24 vJ
STAR SPECIAL FLANGE BRACE SHEET
BUILDING USING SQUARE TUBE JOB N0. 10-B-96059
SYSTEMS I DATE/BY 09/10/2004 vl
3/8" STITCH
PLATES W/
(1)3M'0
A 325 BOLT
UNLESS
NOTED
TS 7x7X3/16 W/ 1/2" CAP PLATES
AND (4) 3/4" 4) A325 BOLTS EACH END
5'-0 1. .1 5'-0
(2) L 2-1/2 x 2-1/2 x 3/16
w/ (1) 3/4" 4) A325 BOLT
EACH END UNLESS NOTED
OTHERWISE
1. ALL CONNECTION PLATES
3/8" UNLESS NOTED
OTHERWISE
Provide Tube column 1'-0 +/- downhill of interior column/rafter connection on
Roof Bays 1,3,5, 7, 9 & 10.
Tube to be located to clear roof rod bracing and to clear purlin flange braces.
Purlin flange braces to remain.
Code Compliance Division Inspections•
2300 Virginia Avenue
Ft. Pierce, FL: 34982. - O
Phone: (772) 462-1553 Fm: (772) 462-1168 7107
7 77 770�%
.Inspection Notes
Job Address 701 KINGS HWY
---- ---- .--------
ApplicaiionType Master Permit w/subs _
Activity Type (New
Date
Scheduled
Foundation & Slab an
Permit Type Building Commercial
Other
Stories Inspection Area
6"10 5112".
Priority Status
Phone (602) 850-8627
Inspector (Code
Inspector Date Inspected
425
Sewer Connect
0
Pending
.. ....... .
S/2212005
05/19f2005
425
232
125
Sewer Connect
Underground Electric
Tie Beam
0
0
3
Pending
Pending
Pending
91
Scott Attey
05/09/2005
awp_ones
Karl Cundlff
-+ —
Dawn ones
Dawn J no e�
05/09/2005
03224/20051
118
105
148
Column
Form Board Survey
Window/Door Attatchment
3
3
4
n
Pending
Pending
c
238
Electric Rough
5
Pending
423
Plumbing Top Out
5
Pending
351
Mechanical Rough-In(ducts)
5
Pending
140
Construction Rough Framing
6
Pending
141
Insulation
7
Pending
179
Firewall
8
Pending
260
30 Day for Testing
9
Pending
165
Handicap Restrooms
9
Pending
460
Plumbing Final
9
Pending
380
Mechanical Final
9
Pending
280
Electric Final
9
Pending
801
Paving and Drainage Certific
9
Pending
,
803
Parking/Handicap Sign & Stri
9
Pending
805
Environmental, Sea Turtle (D
9
Pending
808
Landscaping/Trees
9
Pending
996
Final Termite Treatment
9
Pending
457
Fire Sprinkler Final
9
Pending
180
Building Final
10
Pending
700
Fire Department Final
11
Pending
999
Final Inspection
12
Pending
IVR Access
03/11/2005
110
Footer/Foundation
0
Disapproved
Don Determan
03/11/2005
Dawn Jones
04/18/2005
103
Euffer Ground
0
Approved
Scott Attey
04/18/2006
Mary Jackson
04/07/2005
115
Slab
0
Partial Approval
Don Determan
04/0712005
Lynette Hamilton
04/04/2005
121
Termite Spray
0
Partial Approval
Don Determan
04/04/2005
Dawn Jones
04/16/2005
121
Termite Spray
0
Approved
Scott Attey
04/18/2005
Frank Williams
04/06/2005
900
Plan Revision
0
Approved
Billy Hatcher
04/06/2005
Dawn Jones
04/18/2005
115
Slab
0
Approved
Scott Attey
04/18/2005
Lynette Hamilton
04/20/2005
110
Footer/Foundation
0
Approved
Scott Attey
04/20/2005
Dawn Jones
03/21/2005
232
Underground Electric
0
Rollover to Next Day
Greg Smyth
03/21/2005
Dawn Jones
03/22/2005
110
Footer/Foundation
1
Partial Approval
Don Determan
03/22/2005
Dawn Jones
03/07/2005
121
Termite Spray
1
Approved
Don Determan
03/07/2005
Disunite Joseph
03/16/2005
420
Plumbing Rough
1
Disapproved
Greg Smyth
03/1612005
Dawn Jones
03/03/2005
104
Compaction Test
1
Approved
Dawn Jones
03/03/2005
Dawn Jones
03/25/2005
119
Stem wall
1
Approved
Scott. Attey
03/25/2005
Dawn Jones
03/07/2005
110
Footer/Foundation
1
Approved
Don Determan
03/07/2005
Judy Brenner
03/17/2005
420
Plumbing Rough
1
Disapproved -Reinspect Fr
Greg Smyth
03/17/2005
Mary Jackson
03/21/2005
420
Plumbing Rough
1
Approved
Greg Smyth
03/21/2005
2400 Rhode Island Avenue
Ft Pierce, FL 34950
L, .1. , ^ram � •
ST LUCIE COUNTY FIRE DISTRICT
BUREAU OF FIRE PREVENTION
PLAN REVIEW
Telephone: 772-462-8306
FAX: 772-462-8466
!.,
( ew Construction ( )Tenant Improvement ( )Addition ( )Renovation/alterations
( )Shell Only
Jurisdiction: SLC F.P.B.:
B-04-583
Occupancy: Builders First Choice - Truss Bldg. C. Building Dept:
24101904
Address: 710 S. Kings Hwy. Number of stories:
Contractor Mark Construction Phone #
407-831-6275
Contractor's Address:, 421 Gold Medal Court City:
Longwood
State: FL Zip Code:
32750.."'- '
Architect/Engineer: Stephen A. Brock Architects, Inc. Phone#
561-622-4480
Building Owner: �• Review Date:,-;
1/3/2004
Occupancy Type: Industrial ' Automatic sprinklers:
{r . Gross sq ft: 41,600 Net sq ft:
Occupant Load: Based On:
Construction Type: SBCCI Type:
IV unp .
:NOTE
1. All revisions must be in compll�nce before the final inspection.
2. The Fire Marshal requires 24 hour notice on all inspections.
3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office.
4. Permit fees are required to be paid in full prior to any inspections.
5. Failed inspections require payment of fee prior to rescheduling of further inspections.
6. A copy of the required revision/s have been transmitted to the Architect () Contractor ( ).
7. Penetrations through rated assemblies shall be of proper UL design.
8. UL design criteria shall be submitted with the construction plans.
9. Fire Alarm Panels shall be located indoors.
THE FLORIDA FIRE PREVENTION CODE, 2001 EDITION IS CURRENTLY ENFORCED.
REVISIONS REQUIRED
ACCESS BOX IS REQUIRED ( ) ACCESS KEY SWITCH REQUIRED
( )
1. Provide portable fire protection throughout.
Reviewed by: Date: 1/3/2004
n rl• �, 2r n + � S
ST LUCIE COUNTY FIRE DISTRICT
BUREAU OF FIRE PREVENTION
PLAN REVIEW
(D
2400 Rhode Island Avenue
Ft Pierce, FL 34950
ew Construction ( )Tenant Improvement ( )Additior
Jurisdiction: SLC
Occupancy: Builders First Choice Manufac. Bldg. A
Address: 710 S. Kings Hwy.
Contractor Mark Construction
Contractor's Address: 421 Gold Medal Court
State: FL
Architect/Engineer: Stephen A. Brock Architects, Inc. '
Building Owner:
Occupancy Type: Industrial
Gross sq ft: 72,405
Occupant Load:
Construction Type:
Telephone: 772-462-8306
FAX: 772-462-8466
( )Renovation/alterations
F.P.B.:
Building Dept:
- Number of stories:
'�'Phone #
NCity:
-Zip Code:
Phone #
Review Date:
Automatic sprinklers:
Net'sq ft:
Based On:..
SBCCI Type:
( )Shell Only
B-04` 582
24100909
s
407-831-6275
Longwood
327,50
'561-622-4480
'12/2612004
.Required
IV urip
NOTE
1. All revisions must be in compliance before the final inspection.
2. The Fire Marshal requires 24 hour notice on all inspections.
3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office.
4. Permit fees are required to be paid in full prior to any inspections.
5. Failed inspections require payment of fee,prior to rescheduling of further inspections.
6. A copy of the required revision/s have been transmitted to the Architect () Contractor ( ). ,.
7. Penetrations through rated assemblies shall be of proper UL design. ,
8. UL design criteria shall be submitted with the construction plans.
9. Fire Alarm Panels shall be located indoors.
THE FLORIDA FIRE PREVENTION CODE, 2001 EDITION IS CURRENTLY ENFORCED. p
REVISIONS REQUIRED
ACCESS BOX IS REQUIRED ACCESS KEY SWITCH REQUIRED( )
1. A separate permit is required for the jnstallation of the fire sprinkler system. Monitoring is required.
�. 2. A "separate permit is required for the installation of the fire alarm system.
3. Provide.an exit light fixture above door number 213.
4. Automatic fan shutdown is required for the HVAC systems. Provide duct -detectors in the supply air.
Reviewed by: y�, Date: 12/28/2004
ounry
g Department
iAenue
,L 34992
.1
1553
hid -Load Compliance.
euetneer. This Certification must be submitted with all
dense (single or multi• family), residential addition, any
structure. This Certification shall not apply to interior,
component is being effected) and certain other minorbuilding
Difice at 462-1553 or 462-2172. .
TrVjOCE NiM& ata
wars Sr
Office Use Only
Sweet Address
!
Icimstruction
Permit Numb"
Occutiancy TYL)c
Type
NT_
Certification Statement:
Lcertify.ow:.ta ffic.licst of&y.. XnmlWjp-..and be I hef, these plans and specifications have been deiigned to
comply wi6ifiiapplicable structural portion of the Building Codes currently adopted and enforced by St. Lucie
,County.A.also ceitify that depicted on these plans provide adequate resistance to the wind
loads and f6rces specified by.currint code. Provisions."
DcslZn Parameters and Assumptions Used: ME(please check or complete the appropriate box.)
I-Morida Building Code-Idiflon ASCE 7-98
2. Building Design is (check Parliaily-Enclosed-_ Open Building-
3. Building Height, Wind -Speed -Used in Building Design: l30 3 second gust
5. Wind Exposure Classification (refer to exposure tables In Building Code Identified in Tine #i):
6. Average Wind VieFocity. Faces orStructure __9-!_PSF
7. Peak Wind Velocity Pressure on Exterior Faces of Structure' _PSF
&
9.-Loads:. . Floor iV0_0M R@4dc&d.-2__c0PSF Roofilive _2.0 PSF
10. Were Shear Walls'Considered for Structure (check one): Yes ✓ No —(if No, attach explanation)
tes V' No T (if No,
attach explanation):
17. Are Component and Cladding Detail Provided (check one): Yes No explanation).
—(if No, attach expla on
Li-minimuins,oit.Bearwirre*suer. - -S06bPSF:,_
As witnessed
itnessed by my seal, I hereby certify that the information induided with this certification Is true and
correct, to the best of -my Knowledge andIelkf.-,
Rx re'u a
Name: Certificafien't'. Isqa, Hem)
T:
Design Firm, Lu oy Ditc:
9bCCDV Form 0 02M
7W_10�
Product Review Affidit
St Lucie County, Public Works Department
Code Compliance Division
The following products will be installed in the structure located at
Building Permit.# 2390-M.-Camelback-Road, Suite..,210
Owners Name NSHE Hardinsburg, LLO gwner's,Address Phoenix, AZ 85016
Contractor's,Address 421 Gold Medal Court Contractor Mark 'Construction Co�. , _
` Longwood, Florida 32750
Product
*Product Rated
Desi Pressures
Manufacturer
Model Numtier
Method of Attachment
Windows ' -
"Fill [if the rated wind design pressures fisted by the manrrfdeturerfor each product listed
.1st Choice
130.
YQi
YES45FS
OA # 03-0801-04
Mullions
fixed Glass _
1st Choice
130 ,'
YRK
YES45FS
OA P 03-0801-04
Skylights
Glass (other)
Butt Glass
Glass Block
N-A. `
Sliding Glass Doors
1st Choice
2nd Choice ,J,,
N.A.
Swink Type Doors
IstChoice
On NOA as Lis.
Steelcraft:
1116 Required
2nd Choice v, ,w
130
YRR
20D DA # 03-0801-06
Overhead Garage Doors ._
a
, . -
1st Choice
37 —42
Clopay
524146
Required
2nd Choice ,u w
+31.41-34.5
Cookson
FCFLAB
Required
Roofing Material
7.1
Asphalt/Fiberglass
N-A.
Metal
52_5 psf
Star
Starshield
Standing Seam Clip
Other (Metal)
52.5 .psf
Star
Durarib
Thru Fastened
butters
Choice
N-A.
I have reviewed the above components and cladding, and have approved their use iti e
provide adequate resistance to the wind loads and forces specified by Curren a _vs
Name: Signature
Design Firm J�J X /�Gle Cert. No.__��_YZ 'Date:
to -
•. It O R.11 D�_A
a,
71
The followingproducts will be ii stalled in the stricture located at s
Building Permit 2390 E. Camelback Road, Suite 210
Owners Name _ NME Hardansburg, LLC Owner's Address Phoenix, Az 85016
Contractor Nark, Conscraction Co. Contractor's Address 421 Gold Medal Court
Longwood, Florida 32750 Al
Product *Product Rated Manufacturer Model:Number Method of Attachment
Design Pressures
N'Viudows tr Fill in the rated wind design pressures listed by the raanrrjactnrerjor each pYbdriet)listed
Firoduc$ Review Affidavit
St Lucie County, Public Works Deparhnent
Code Compliance Division
1st Choice 130 YKIC YES45FS O® $ •03-0801. 04'•
Mullions
iced Glass
-I st Choice
Skylights
i
Glass (other)
130 f YKK
Butt Glass N.A.
Glass Block N.A.
Sliding Glass Doors
1st Choice
2nd Choice „f.� N.A:
Swing Type Doors
IstChoice on NOA as lis Steelcraft" H16 s Required
2nd Choice,s,� 130 YRx 20D OA # 03-0801-06
Overhead Garage Doors
1st Choice
37 —42 „
I Clopay
524116 Required
2nd Choice,,(,o ..
31.4/-34.5 , .
Cookson
FCFLAB Required
Roofing Material
Asphalt/Fiberglass
N.A.
Metal
52.5 psf
Star
Starshield
Standing Sean,Clip
.1 IOtlfer'(Netal)
'523 psf
Star
Durarib
Thru Fastened
'butters ,
Choice
I have reviewed the:above components and cladding, and have approved
provide adequate resistance to the wind loads and forces specifiedAbycu
Name: Signature
Design Firm Celt. No.---_� -
ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
EnergyGauge FlaCom v1.22 FORM 40OA-2001
Whole Building Performance Method for Commercial Buildings
Jurisdietion: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000)
Short Dese:
PRO SOURCE
Project: PRO SOURCE OFFICE
Owner:
Enter Owner's name here
Address:
Enter Address here
Enter Address here
City:
FT. PIERCE
State:
FLORIDA
PermitNo: ;L `i 10 1 °1 O'
Zip:
0
Storeys: 1
Type: Office (Business) GrossArea: 3120
Class: New Finished building Net Area: 3120
Max Tonnage: /.'(if different, write
c �
Compliance Summary
Component Design Criteria Result
Gross Energy Use 93.07 100.00 PASSES
Other Envelope Requirements - A PASSES
LIGHTING CONTROLS
EXTERNAL LIGHTING
HVAC SYSTEM
PLANT
WATER HEATING SYSTEMS
PIPING SYSTEMS
Met all required compliance from Check List?
PASSES
PASSES
PASSES
PASSES
PASSES
PASSES
Yes/No/NA
IMPORTANT NOTE. An input report Print -Out from EnergyGauge FlaCom of
this design building must be submitted along with this Compliance Report.
11/9/2004
EnergyGauge FlaCom FLCCSB v1.22
1
COMPLIANCE CERTIFICATION:
I hereby certify that the plans and
Review of the plans and specifications covered by this
specifications covered by this calculation are
calculation indicates compliance with the Florida Energy
in compliance with the Florida Energy
Code. Before construction is completed, this building will be
Efficiency Code,
inspected for compliance .in accordance with Section
553.908, F.S.
PREPARED BY:
oBUILDING OFFICIAL:
DATE: /
DATE:
I hereby certify that this building is in compliance
with the Florida Energy Efficiency Code.
OWNER AGENT:
DATE:
If required by Florida law, I hereby certify (')
that the system design is in
compliance with the Florida Energy Code.
REGISTRATION
No.
I n
ARCHITECT: S�tphGv� rod< ANC.0007 (03e
ELECTRICAL SYSTEM DESIGNER:
G e f3. Rw5 F No. 3)-3 %. O
LIGHTING SYSTEM DESIGNER:
MECHANICAL SYSTEM DESIGNER:
PLUMBING SYSTEM DESIGNER:
(') Signature is required where Florida Law requires design to be performed by registered design professionals.
Typed names and registration numbers may be used where all relevant information is contained on signed/sealed
plans.
11/9/2004 EnergyGauge FlaCom FLCCSB v1.22
Project: PRO SOURCE
Title: PRO SOURCE OFFICE
Type: Office (Business)
Location: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000)
(WEA File: DAYTONABEA
Whole Building Compliance
_Design Reference
Total 93.07 100.00
ELECTRICITY 93.07
100.00
AREA LIGHTS 16.58
23.33
MISC EQUIPMT 9.70
9.70
PUMPS & MISC 0.09
0.09
SPACE COOL 21.87
22.06
VENT FANS 44.82
44.82
Credits & Penalties (if any): Modified Points: = 93.07 PASSES
Project: PRO SOURCE
Title: PRO SOURCE OFFICE
Type: Office (Business)
Location: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000)
(WEA File: DAYTONABEA
Other Envelope Requirements
Item Zone Description Design
Limit Meet Req.
PrOZo2Rf1 PrOZo2 Exterior Roof -Max Uo Limit 0.05
0.09 Yes
Meets Other Envelope Requirements
11/9/2004 EnergyGauge FlaCom FLCCSB v1.22 3
External Lighting Compliance
Description
Category Allowance Area or Length ELPA CLP
(W/Unit) or No. of Units (W) (W)
(Sgft or it)
None
Project: PRO SOURCE
Title: PRO SOURCE OFFICE
Type: Office (Business)
Location: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000)
(WEA File: DAYTONABEA
Lighting Controls Compliance
Acronym Ashrae
Description Area No. of Design Min Compli-
D)
(sq.ft) Tasks CP CP ance
PrOZolspl 26
Offices (Partitions>4.5ftbelow 1,560 1 2 2 PASSES
ceiling) Enclosed offices, all open
plan offices without partitions
PrOZo2Sp1 26
Offices (Partitions>4.5 ft below 1,560 1 4 2 PASSES
ceiling) Enclosed offices, all open
plan offices without partitions
PASSES
11/9/2004 EnergyGauge FlaCom FLCCSB v1.22
Project: PRO SOURCE
Title: PRO SOURCE OFFICE
Type: Office (Business)
Location: ST LUCIE COUNTY, ST LUCIE COUNTY, FL (661000)
(WEA File: DAYTONABEA
System Report Compliance
PrOSyl System 1 Constant Volume Air Cooled No. of Units
Split System < 65000 Btu/hr 1
Component Category Capacity
Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System Air Cooled < 65000 Btu/h
Cooling Capacity
Air Handling Air Handler (Supply) -
System -Supply Constant Volume
10.00 10.00 9.30 PASSES
0.80 0.80 PASSES
PrOSy2 System 2
Constant Volume Air Cooled No. of Units
Split System < 65000 Btu/hr 1
Component Category Capacity
Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System Air Cooled <65000 Btu&
Cooling Capacity
Au Handling Air Handler (Supply) -
System -Supply Constant Volume
10.00 10.00 8.30 PASSES
0.80 0.80 PASSES
PASSES
Plant Compliance
Description Installed Size Design Min
No Eff Eff
Design Min Category Comp
IPLV IPLV liance
None
Water Heater Compliance
Description Type Category
D
Design Min Design Max Comp
Eff Eff Loss Loss liance
None
11/9/2004 EnergyGauge FlaCom FLCCSB v1.22
Piping System Compliance
Category
Pipe Dia Is Operating Ins Cond Ins Req Ins
Compliance
[inches] Runout? Temp [Btu-in/br Thick [in] Thick [in]
[F] SF.FJ
None
Project: PRO SOURCE
Title: PRO SOURCE OFFICE
Type: Office (Business)
Location: ST LUCIE COUNTY, S
Other Required Compliance
Category
Section
Requirement (write N/A in box if not applicable)
Check
Infiltration
406.1
Infiltration Criteria have been met
System
407.1
HVAC Load sizing has been performed
Ventilation
409.1
Ventilation criteria have been met
ADS
410.1
Duct sizing and Design have been performed
T & B
410.1
Testing and Balancing will be performed
Electrical
413.1
Metering criteria have been met
Motors
414.1
Motor efficiency criteria have been met
Lighting
415.1
Lighting criteria have been met
O & M
102.1
Operation/maintenance manual will be provided to owner
Roof/Ceil
404.1
R-19 for Roof Deck with supply plenums beneath it
El
Report
101
Input Report Print -Out from EnergyGauge F1aCom attached?
El
11/9/2004 EnergyGauge FlaCom FLCCSB v1.22
ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
EnergyGauge FlaCom v1.22
INPUT DATA REPORT
Proiect Information
Project Name:
PRO SOURCE
Orientation:
North
i
Project Title:
PRO SOURCE OFFICE
Building Type:
Office (Business)
Address:
Enter Address here
Building Classification:
New Finished building
Enter Address here
No.of Storeys:
1
State:
FLORIDA
Zip:
0
GrossArea:
3120
Owner:
Enter Owner's name here
Zones
No Acronym Description
Type Load Profile
Area
Multiplier Total Area
lsil
lsfl
b
1. , PrOZol Zone 1
CONDITIONED Uses Building Load
1560.0
1 1560.0 ❑
Profile
2 PrOZo2 Zone 2
CONDITIONED Uses Building Load
1560.0
1 1560.0 ❑
Profile
ll/.9/2004
EuergyGauge FlaCom FLCCSB v1.22
1
0
t
Spaces
No Acronym Description
Type
Depth Width
height Multi Total Area
Total Volume
IN IN
[ft] plier
[sf]
len
In Zone: PrOZol
1 Pr0ZolSpl ZoOSpl
Offices (Partitions>4.5 ft
26.00 60.00
8.00 1
12480.0
El
below ceiling) Enclosed
offices, all open plan offices
without partitions
In Zone: PrOZo2
1 PrOZo2Spl ZoOSpl
Offices (Partitions>4.5 ft
60.00 26.00
8.00 1
1560.0
12480.0
below ceiling) Enclosed
offices, all open plan offices
without partitions
Lighting
No Type
Power
Control Type
No.of
[W]
Ctrl pts
In Zone: PrOZol
In Space: Pr0Zo1Sp1
i Suspended Fluorescent
2000.00
Manual On/Off
2
❑
In Zone: PrOZo2
In Space: Pr0Zo2Sp1
1 Suspended Fluorescent
2000.00
Manual On/Off
4
❑
Walls
No Description Type
Width H (Effec) Multi Area
DirectionConductance
Heat
Dens. R-Value
[ft] [ft]
plier [sf]
[Btu/hr. sf. F]
Capacity
[lb/cf] [h.sf.FBtu]
[Btu/sf.F]
In Zone: PrOZol
11/9/2004
EnergyGauge F1aCom FLCCSB v1.22
I
PrOZolWal
5/8" stucco
60.00
8.00 1
480.0
West
0.2067
5.7314
34.65
4.84
/8"CMU/3/4"ISO
BTWN24"oc/.5"
Gyp
2
PrOZolWa2
5/8" stucco
60.00
8.00 1
480.0
East
0.2067
5.7314
34.65
4.84
/8"CMU/3/4"ISO
BTWN24"oc/.5"
Gyp
3
PrOZolWa3
5/8" stucco
38.00
8.00 1
304.0
North
0.2067
5.7314
34.65
4.84
/8"CMU/3/4"ISO
BTWN24"oc/.5"
Gyp
4
PrOZol Wa4
5/8" stucco
38.00
8.00 1
304.0
South
0.2067
5.7314
34.65
4.84
Ej
/8"CMU/3/4"ISO
BTWN24"oc/.5"
Gyp
In Zone: PrOZo2
1
PrOZo2Wa1
0.75 in. stucco,
60.00
8.00 1
480.0
East
0.1118
1.1829
14.94
8.94
Ej
2x4xl6" oc,
RI Matt, 0.5 in. gyp
2
PrOZo2Wa2
0.75 in. stucco,
60.00
8.00 1
480.0
West
0.1118
1.1929
14.94
8.94
❑
2x4xl6" oc,
R11Batt, 0.5 in. gyp
3
PrOZo2Wa3
0.75 in. stucco,
26.00
8.00 1
208.0
North
0.1118
1.1829
14.94
8.94
❑
2x4xl6" oc,
RI Matt, 0.5 in. gyp
4
PrOZo2Wa4
5/8" stucco
26.00
8.00 1
208.0
South
0.2067
5.7314
34.65
4.84
/8"CMU/3/4"ISO
BTWN24"oc/.5"
GYP
Windows
No
Description Type
Shaded
UCen SC
Vis.Tr
W
H (Effec)
Multi
Total Area
[Btu/hr sf F]
IN
[ft]
plier
[sf]
In Zone: PrOZol
In Wall: PrOZo1Wa2
]
PrOZolWa2Wi1 SINGLECLEAR No
1.0018 0.95 0.88
3.00
5.00
1
15.0
21
ll/?/2004 EnergyGauge FlaCom FLCCSB vl.22
Skylights
No Description Type
UCen Shading Vis.Trans W H (Effet) Multiplier
Area Total Area
[Btu/hr sf F] Coeff [ft] [ft]
[91 [Sf]
In Zone:
In Roof:
01
Floors
No Description Type
Width H (Effec) Multi Area Cond. Heat Cap. Dens.
R-Value
[ft] [ft] plier [sf] [Btu/hr. sE F] [Btu/sL F] [Ib/cf]
[h.sf.FBtu]
In Zone: PrOZol
1 PrOZolFll I ft. soil„concrete
60.00 26.00 1 1560.0 0.1745 54:00 108.00
5.73
❑
floor, carpet and
rubberpad
Systems
PrOSyl System 1
Constant Volume Air Cooled Split No. Of Units 1
System < 65000 Btu/hr
Component Category
Capacity Efficiency IPLV
I Cooling System (Air Cooled < 65000 Btu/h Cooling 60000.00 10.00 8.30
❑
Capacity)
2 Air Handling System -Supply (Air Handler (Supply) - 2000.00 0.80
❑
Constant Volume)
11/9/2004 EnergyGauge FlaCom FLCCSB v1.22
5
PrOSy2 System 2 Constant Volume Air Cooled Split No. Of Units 1
System < 65000 Btu/hr
Component Category Capacity Hfficiency ITLV
1 Cooling System (Air Cooled < 65000 Btu/h Cooling 60000.00 10.00 8.30 ❑
Capacity)
2 Air Handling System -Supply (Air Handler (Supply) - 2000.00 0.80 ❑
Plant
Equipment Category Size Inst.No 1 ff. IPLV
Water Heaters
W-Heater Description Capacit Cap,Unit i/P at. ]Efficiene Loss
�i.t-Lig�ltua��
Description Categories.
Area/Len/No. of units
[sf/fft/No]
Wattage
fWj
b
Piping
No Type Operating Insulation
Temperature Conductivity
[r? (Bku-in/h.sf.Fj
Nomonal pipe
Diameter
finj
Insulation Is Runout?
Thicknesg
[in]
11/9/2004
PnergyGauge F1'aCom FLCCSB v1.22
6
Fenestration Used
Name
Glass Type No. of
Glass
Conductance
SC
VLT
Frame
Conductance Absorptance
Frame
Panes
[$tu/h.sf.Fl
[Btn/h.sf.F1
ApLbWndl
SINGLE CLEAR 1
1.0018
0,9500
0.8810
0.4340
0.7000
❑
Materials Used
Only R-Value
RValue Thickness
Conductivity
Density
SpecificHeat
Mat No
Acronym
Description
Used
[h.sf.F/Btu1
[fil
[Btu/h.ft.F1;
[lb/eq
[Btu/lb.F]
18
MatII8
2 in. Wood
No
2.3857
0.1610
0.0700
37.00
0.3900
❑
264
Mat1264
ALUMINUM, 1/16IN
No
0.0002
6.0050
26.0000
480.00
0.1000
❑
214
Mat1214
POLYSTYRENE, EXP.,
No
5.2100
0.1042
0.0200
1.90
0.2900
❑
MAIN,
❑
187
MatII87
GYP OR PLAS
No
0.4533
0.0417
0.0520
50.00
0.2000
BOARD,1/2I14
206
Mat1206
CELLULOSE,FI1,L,5.5IN,R-
No
26.8318
0.4583
0.0220
3.00
0.3300
20 '
151
Mat1151
CONC 14W, DRD,140LB,
No
0.4403
0.3333
0.7570
140.00
0.2000
❑
41N
178
Mat1178
CARPET W/RUBBERPAD
Yes
1.2300
❑
265
Mat1265
Soil, 1 ft
No
2.0000
1.0000
0.5000
100.00
0.2000
❑
48
Mat148 1
6 in. Heavyweight concrete
No
0.5000
6.5000
1.0000
140.00
0.2000
❑
123
Mat1123
CONCBLOCK
No
1.7227
0.6667
0.3870
53.00
0.2000
MW,8IN,HOLLOW
159
Mat1159
CONC
No
0.3202
0.3333
1.0410
M0.00
0.2000
❑
HW-UNDRD-140LB-41N
57
MOM
3/4 in. Plaster or gypsum
No
0.148.8
6.0625
0.4200
100.00
0.2000
❑
72
Mat172
AIR LAYER, 3/4IN OR
Yes
0.9000
❑
LESS, VERT, WALLS
267
Mat1267
0.75" stucco
No
0.1563
0.0625
0.4000
16.00
0.2000
�]
266
Mat1266
2x4@16" oc+k11 Batt
No
8.3343
0.2917
0.0350
9.70
0.2000
❑
11/9/2004
EnergyGauge F1aCom FLCCSB v1.22
287
Mat1287
Polyurethane core (24 ga
Yes
4.1500
❑
steel) 2
❑
288
Mat1288
Solid Urethane foam core
Yes
4.1'500
81
Matl81
ASPHALT -ROOFING,
Yes
0.1500
❑
ROLL
244
Matl244
PLYWOOD, 1/21N
No
0.6318
0.0417
0.0660
34.00
0.2900
❑
185
Matll85
CLAY TILE, PAVER, 3/8IN
No
0.0301
0.0313
1.0410
120.00
0.2000
❑
82
Mat182
ASPHALT -SHINGLE AND
Yes
0.4400
❑
11
Matll 1
SIDING
2 in. Insulation
No
6.6900
0.1670
0.0250
2.00
0.2000
❑
47
Mat147
2 in. Heavyweight concrete
No
0.1670
0.1670
1.0000
140.00
0.2000
❑
95
Matl95
CONC BLOCK
No
0.7107
0.3333
0.4690
101.00
0.2000
❑
HW4IN-HOLLOW
248
Mat1248
ROOF GRAVEL OR
No
0.0500
0.0417
0.8346
55.00
0.4000
❑
SLAGI/2IN
94
Mat194
BUILT-UP ROOFING,
No
0.3M6
0.0313
0.0930
70.00
0.3500
❑
3/8IN
Constructs Used
Simple
Massless Conductance
Heat Capacity
Density
RValue
No
Name
Construct
Construct [Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.FBtu]
1002
Aluminum door, 1.25 in. polystyrene
No
No
0.19
033
43.67
5.2104
❑
Layer
Material Material
Thickness
Framing
No.
[it]
Factor
1
264 ALUMINUM, 1/16114
0.0050
0.00
❑
2
214 POLYSTYRENE,
EXP., 1-1/4IN,
0.1042
0.00
❑
3
264 ALUMINUM, 1116IN
0.0050
0.00
❑
11/9/2004 EnergyGauge FlaCom FLCCSB v1.22 9
Simple
11+Yass1'ess Condu'efauce
Heat Capacity
Density
RValue
Name
Construct
Construct [13tu/h.s£F]
[)3tuAf.F]
[lb/cf
[h.s£.F/Btuj
1005
FFNo
1 ft. soil, concrete floor, carpet and rubber pad No
No 0.17
54.00
108.00
5.7300
C]
Layer
Material
Material
Thickness
Framing
No.
[ft]'
Factor
1
265
Soil, 1 ft
2.0000
0.00
❑
2
48
6 in. Heavyweight concrete
0.500.0
0.00
❑ ',
3
178
CARPET W/RUBBER PAD
0.00
Simple
massless Conductance Heat Capacity
Density
RValue
No
Name
Construct
Construct [Btu/b.S£F]
[$tuM.F]
[]h/cn
]hsfFBtu]
1009
0.75 in. stucco, 2x4xl6" oc, R11Batt, 0.5 in. No
No 0.11
1.18
14.94
8.9438
❑
gyp
I
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
267
0.75" stucco
0.0625
0.00
❑
2
266
2x4@16" oc+R11 $att
0.2917
0.00
d
3
187
GYP ORPLAS BOARD,1/21N
0.0417
0.00
❑
Simple
Massless Conductance Heat Capacity
Density
RValue
No
Name
Construct.
Constritet [i3tu/h.sf.F]
[Btii/sf.F]
[lb/cf]
[hsfF/ 1
1011
5/8" stucco /8"CMU/3/4180 No
No 0.21
5.73
34.65
4.8368
❑
BTWN24"oc/.5"
Gyp
Layer
Material
Material
Thickness
Framing
No.
[£t]
Factor
1
268
0.625" stucco
0.052.1
0.00
❑
2'
42
8 In. Lightweight concrete block
0.6670
0.00
13
3
269
.75" ISO BTWN24" oc
0.0625
0.00
❑
4
187
GYP OR PLAS BOARD,1/2IN
0.0417
0.00
❑
11/9/2004 $nergyGauge FlaCom FLCCSB v1.22 10
No Name
Simple
Construct
Massless Conductance
Construct [Btu/h.sf.F]
Heat Capacity
[Btu/sf.F]
Density
[lb/cf]
RValue
[b.sEF/Btn]
1039 Shngl/1/2"WD Deck/WD Truss/6'Batt/Gyp No
No 0.05
1.40
10.89
21.2351 ❑
Brd
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
81
ASPHALT -ROOFING, ROLL
0.00
❑
2
244
PLYWOOD, 1/2IN
0.0417
0.00
❑
3
23
6 in. Insulation
0.5000
0.00
❑
4
187
GYP OR PLAS BOARD,1/2IN
0.0417
0.00
❑
11/Q/2004
EnergyGaugeFlaCom FLCCSB v1.22
11
e
Sheet
i
PLANS t 0.240 dm 13, `240 cfm 2000 dm �243 dm
0.229 cfm
WOMEN
LUNCH RM MEN
0.87dm
[� 0.243 dm
PLANS 2 1240 dm �240 dm
0.237 dm
Job #: PRO SOURCE Scale: 1 : 121
Performed by WG for: Page 1
Right -Suite Commerclal
PRO SOURCE 5.0.17 RSC60847
LUNCH/OFFICE 2004-Nov-09 15:11:58
FT. PIERCE, FL 34945 C:1My Documents\Wrightsoft WA...
SECOND FLOOR
2000 dm
0.,4, dm
[� [� OFFICE 3
0.229 dm 1229 dm 1229 d
0.,4, dm
GENERAL OFFICE
I� 0.,73 dm
\229 dm 0. OFFICE 2
229 dm 229
0.173 dm
Job M
Performed by WG for:
PRO SOURCE
LUNCH/OFFICE
FT. PIERCE, FL 34945
PRO SOURCE
Scale: 1 : 121
Page 2
Right -Suite Commercial
5.0.17 RSC50847
2004-Nov-09 15:11:58
CAMy DocumentsMrightso$ HVA...
Right -Suite Commercial Load Summary
It UNIT TWO
PRO SOURCE Job: 111612004
Project Information
For: PRO SOURCE
LUNCH/OFFICE, FT. PIERCE, FL 34945
Zone: ON(T TWO ` COOLING'IOAD
1.
DESIGN CONDITIONS at Jul 1500
Peak load at Jul 1500
Inside: 75 OF Outside: 90 OF
TD:
15 OF
RH: 50 % Moisture: 61.4 gr/lb
Mult:
1.0 Ins.wb
63 OF
Sensible
Latent
2.
SOLAR RADIATION THROUGH GLASS
5693
-
3.
TRANSMISSION GAINS Sensible
9843
-
Walls: 1369
-
-
Glass: 2172
-
-
Doors: 110
-
-
Partitions: 0
-
-
Floors: 0
-
Roofs/Ceilings: 6192
-
Return Air Ceiling: 0
4.
INTERNAL HEAT GAIN Sensible
Latent
19020
2069
Occupants: 2587
2069
-
-
Lights: 12726
-
Motors: 0
-
Appliances: 3707
0
-
-
5.
INFILTRATION: Outside air cfm:
10
165
425
6.
SUBTOTAL: Space load
34720
11281
7.
SUPPLY DUCT
1042
-
8.
SUBTOTAL: Bldg comp's and supply duct
35762
Actual cfm: 2000 at Supply TD:
20
-
-
9.
VENTILATION: Make-up air cfm:
207
3414
8787
10.
RETURN AIR LOAD: Lighting & roof (net)
0
-
11.
RETURN DUCT
0
-
12.
TOTAL LOADS ON EQUIPMENT
39176
11281
HEATING LOAD:
13.
DESIGN CONDITIONS
MUIt:
1.0
Inside: 70 OF Outside: 42 OF
TD:
28 OF
14.
TRANSMISSION LOSSES
13395
Walls: 2240
-
Glass: 4435
-
Doors: 212
-
Partitions: 0
-
Floors: 3901
-
Roofs/Ceilings: 2607
-
Return Air Roof: 0
-
15.
INFILTRATION: Outside air cfm:
82
2528
16.
SUBTOTAL: Building components
15923
17.
SUPPLY DUCT:
478
18.
VENTILATION: Make-up air cfm:
207
6374
19.
HUMIDIFICATION
1569
20.
RETURN DUCT
0
21.
TOTAL HEATING LOAD ON EQUIPMENT
24344
wrrghtsoft Right-Suhe Commemia15.0.17 RSC5o847 2004-NOv 0915:12:09
C-.Wy DowmentslWnghtsofl WAMPRO-SOURCE OFFICE-LUNCH.Mc Page i
Right -Suite Commercial Load Calculation
ti PLANS 1
PRO SOURCE Job: 11/6/2004
For. PRO SOURCE
LUNCH/OFFICE, FT. PIERCE, FL 34945
Zone: PLANS l."
LWH:
13.0
x
16.0 x 8.0
1. DESIGN CONDITIONS - COOLING
( Jul 1700 )
.
Dry Bib RH
Moisture Range Wet Bib
Outdoor Conditions
89 62
15
78
Indoor Conditions
75 50
63
TOD Correction
2
Difference
14
61.4
i Mult = 1.0 ] —
2. GLAZING SOLAR HEAT GAIN
( Lat = 27.45
°N
Const Wt
= M )
Type Orien Shad
Tilt
%ovr
Area Sc
Shgf Shad
Sens
n/a 0 n/a
0
0 0.00
0 0.0
0
3. TRANSMISSION GAINS
Type Orien GrArea
NtArea
Uval Grp
CLTD
Shad Clr
Sens
WALL 3 N 128
128
0.137 D
16.5
N
D 289
WALL 3 W 104
83
0.137 D
24.5
N
D 279
DOOR 6 w 21
21
0.360
13.5
102
FLOR 1 - 29
29
0.810
0.0
0
4. INTERNAL HEAT GAIN
Sens Latent
PEOPLE
Activity
Total
Sensible
Latent
Schedule
ft2/prsn
# people
Btuh/prsn
Btuh/prsn
Office
150
0 1
250
200 347 277
8to6
0
0 0
0
0 0 0
wnghtsoft Right -Suite Co etcial5.0.17 RSC50847 2004-NOV-0916:12:27
CWy D=aneetsMhightsaft HVACIPRO-SOURCE OFFICE-LUNCH.me Page 1
• LIGHTS
Type
Total
Factor
Space
Schedule W/ftz
W W
Btuh/W
Tract
Fluorescent 2.00
0 416
4.10
1.0
1706
8to6
Fluorescent 0.00
0 0
4.10
1.0
0
Fluorescent 0.00
0 0
4.10
1.0
0
Fluorescent 0.00
0 0
4.10
1.0
0
PLUG LOADS / APPLIANCES
-
Application
Usage Total
Sensible
Latent
Schedule
Btuh
Btuh
Plug load W/ft'
W
8to6 0.7
0 1.00 146
3
0
497
0
#/ft'
#
0.0
0 1.00 0
0
0
0
0
#/ft'
#
0.0
0 1.00 0
0
0
0
0
#Ift'
#
0.0
0 1.00 0
0
0
0
0
#/ft'
#
0.0
0 1.00 0
0
0
0
0
#/ftz
#
0.0
0 1.00 0
0
0
0
0
MOTORS
Power (hp)
Load Total
Sensible
Schedule #/ft2
# factor
Btuh
0.00 0.0
0 1.00 0
0
0
0.00 0.0
0 1.00 0
0
0
0.00 0.0
0 1.00 0
0
0
5. INFILTRATION
Sens
Latent
10 cfm ->
x db Temp Diff
13.5 x 1.10
149
->
x Moist. Diff
61.4 x 0.69
425
6. SUBTOTAL COOLING LOAD FOR SPACE
3368
1880
7. SUPPLY DUCT HEAT GAIN
Gain factor 0.03
x Line 6 Sensible Gain
101
S. COOLING FAN SIZING
Sum of Duct Gain (7 ),
Line (6) & Drawthru
Fan =
3469
(L 8
Sens ) / (Xfer x Supply TD ) =
cfm
Est Cooling Cfm = (
3469) / (1.10 x
20.0 ) =
158
Actual Cooling Fan
> =
229
9. VENTILATION
' 28 cfm ->
x db Temp Diff
13.5 x 1.10
412
->
x Moist. Diff
61.4 x 0.69
1178
10. RETURN AIR LOAD FROM LIGHTING AND ROOF
Lights
Total power (W)
0
1706
RA Roof Load
from Line 3 (+)
0
RA Ceiling Load Credit
- from Line 3 (-)
0
wnghtsoft Right -Suite Commerclai5.0.i7RSC50847
2004-Nov-0915:12:27
C:wiy Dowmems\wrigmsoft HVAC\PRO-SOURCE OFFICE-LUNCH.r=
Page 2
11. RETURN DUCT HEAT GAIN
Gain factor 0.00 x Line 6 Sensible Gain 0
12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 3880 1880
SPACE HEATING LOAD CALCULATION
13. HEATING DESIGN TEMPERATURE
Heating TO = (Inside DB - Outside DB)
_ ( 70 - 42) =
28
Mult = 1.0 ] —
14. TRANSMISSION LOSSES
Type Expos GrArea NetArea Uval
HTD
Loss
WALL 3 N 128 128 0.137
28.0
491
WALL 3 W 104 83 0.137
28.0
318
DOOR 6 w 21 21 0.360
28.0
212
FLOR 1 29 29 0.810
28.0
658
15. INFILTRATION
Loss
28 cfm x db Temp Diff 28.0
x 1.10
872
16. SUBTOTAL HEATING LOAD FOR SPACE
2551
17. SUPPLY DUCT HEAT LOSS
77
Loss factor 0.03 x Line 16 Loss
18. VENTILATION
854
28 cfm x db Temp Diff 28.0
x 1.10
19. HUMIDIFICATION
Inside RH desired 40.0 (Max =
32.0 for 1 pane )
# of Glazing panes 0.0 (Max =
52.0 for 2 pane )
56 cfm x 3.20 g/100cfm/d
= 1.8 gpd
678
20. RETURN DUCT HEAT LOSS
Loss factor 0.00 x Line 16 Loss
0
21. TOTAL HEATING LOAD ON EQUPMENT (Btuh)
4160
wnghtsoft Right-Sufle Commercial 5.0.17 RSCS0847 2004-Nov 0915:12:27
C:Vy DocumemslWrightsoft HVACTRO-SOURCE OFFICE-LUNCH.mc Page 3
Right -Suite Commercial Load Calculation
PLANS 2
PRO SOURCE Job: 1116/2004
For: PRO SOURCE
LUNCH/OFFICE, FT. PIERCE, FL 34945
Zone: PLANS 2
-
LWH:
13.0
x
16.0 x 8.0
1. DESIGN CONDITIONS - COOLING
( Jul 1700 )
Dry Bib RH
Moisture Range Wet Bib
Outdoor Conditions
—>
89 62
15
78
Indoor Conditions
>
75 50
63
TOD Correction
2
Difference
14
61.4
i Mult = 1.0 ] —
2. GLAZING SOLAR HEAT GAIN
( Lat = 27.45
ON ,
Const Wt
= M )
Type Orien Shad
Tilt
%ovr Area SC
Shgf Shad
Sens
n/a 0 n/a
0
0 0.00
0 0.0
0
3. TRANSMISSION GAINS
Type Orien GrArea
NtArea
Uval Grp
CLTD
Shad Clr
Sens
WALL 3 S 128
128
0.137 D
22.8
N
D 400
WALL 3 W 104
83
0.137 D
24.5
N
D 279
DOOR 5 w 21
21
0.360
13.5
102
FLOR 1 - 29
29
0.810
0.0
0
ROOF 1 - 3
3
0.060 R4
67.5
D 11
4. INTERNAL HEAT GAIN
Sens Latent
PEOPLE
Activity
Total
Sensible
Latent
Schedule
ft2/prsn
# people
Btuh/prsn
Btuh/prsn
Office
150
0 1
250
200 347 277
8to6
0
0 0
0
0 0 0
wnghtsoft RIgM-Suite Commemlal S.0.17RSC50947 2004-Nov0915:12:27
C:1AAy DowmentslWAghtsoft HVAMPRO-SOURCE OFFICE-LUNCH.Me Page 1
•
LIGHTS
Type
Total
Factor
Space
Schedule W/ft2
W W
BtuhNV
Tract
Fluorescent 2.00
0 416
4.10
1.0
1706
8to6
Fluorescent 0.00
0 0
4.10
1.0
0
Fluorescent 0.00
0 0
4.10
1.0
0
Fluorescent 0.00
0 0
4.10
1.0
0
PLUG LOADS / APPLIANCES
Application
Usage Total Sensible
Latent
Schedule
Btuh
Btuh
Plug load W/ft2
W
8to6 0.7
0 1.00 146
3
0
497
0
#/ftz
#
0.0
0 1.00 0
0
0
0
0
#/ft'
#
0.0
0 1.00 0
0
0
0
0
#/ft2
#
0.0
0 1.00 0
0
0
0
0
#Ifta
#
0.0
0 1.00 0
0
0
0
0
#/ft'
#
0.0
0 1.00 0
0
0
0
0
MOTORS
Power (hp)
Load Total Sensible
Schedule #/ft2
# factor
Btuh
0.00 0.0
0 1.00 0
0
0
0.00 0.0
0 1.00 0
0
0
0.00 0.0
0 1.00 0
0
0
5.
INFILTRATION
Sens
Latent
10 cfm ->
x db Temp Diff 13.5
x 1.10
149
->
x Moist. Diff 61.4
x 0.69
425
6.
SUBTOTAL COOLING LOAD FOR SPACE
3489
1880
7.
SUPPLY DUCT HEAT GAIN
Gain factor 0.03
x Line 6 Sensible Gain
105
S.
COOLING FAN SIZING
Sum of Duct Gain (7 ),
Line (6) & Drawthru Fan
=
3593
(L 8
Sens ) / (Xfer x Supply
TD ) =
cfm
Est Cooling cfm = (
3593) / (1.10 x 20.0
) =
163
Actual Cooling Fan
>
=
237
9.
VENTILATION
28 cfm ->
x db Temp Diff 13.5
x 1.10
412
->
x Moist. Diff 61.4
x 0.69
1178
10.
RETURN AIR LOAD FROM LIGHTING AND ROOF
Lights
Total power (W)
0
1706
RA Roof Load
from Line 3 (+)
0
RA Ceiling Load Credit
from Line 3 (-)
0
wrightsoft Right -Suite Commercial 5.0.17RSC50847
2004-Nov-0915:12:27
C,.XMy DocumeRslWrightsoft HVACTRO-SOURCE OFFICE-LUNCH.me
Page 2
11. RETURN DUCT HEAT GAIN
Gain factor 0.00 x Line 6 Sensible Gain 0
12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) - 4005 1880
SPACE HEATING LOAD CALCULATION
13. HEATING DESIGN TEMPERATURE
Heating , TD = (Inside DB - Outside DB)
14. TRANSMISSION LOSSES
Type
Expos
GrArea
NetAresi
Uval
WALL
3
S
128
128
0.137
WALL
3
W
104
83
0.137
DOOR
5
w
21
21
0.360
FLOR
1
29
29
0.810
ROOF
1
3
3
0.060
_ ( 70 - 42) =
28
Mult = 1.0 ] —
HTD_
Loss
28.0
491
28.0
318
28.0
212
28.0
658
28.0
4
15.
INFILTRATION
Loss
28 cfm x db Temp Diff 28.0
x 1.10
872
16.
SUBTOTAL HEATING LOAD FOR SPACE
2556
17.
SUPPLY DUCT HEAT LOSS
77
Loss factor 0.03 x Line 16 Loss
18.
VENTILATION
854
28 cfm x db Temp Diff 28.0
x 1.10
19.
HUMIDIFICATION
Inside RH desired 40.0 (Max =
32.0 for 1 pane )
# of Glazing panes 0.0 (Max =
52.0 for 2 pane )
56 cfm x 3.20 g/100cfm/d
1.8 gpd
678
20.
RETURN DUCT HEAT LOSS
0
Loss factor 0.00 x Line 16 Loss
21.
TOTAL HEATING LOAD ON EQUPMENT (Btuh)
4165
Wfl ht50ft Right -Suite Commeroia15.0.17RSC50S47 - 2004-Nov-0915:12:27
C.Wy Dowments\WrIghtsoR WACIPRO-SOURCE OFFICE-LUNCH.rso Page 3
Right -Suite Commercial Load Calculation
WOMEN
PRO SOURCE Job: 111612004'
Rrojeet Information
•-. SOURCE
LUNCH/OFFICE, FT. PIERCE, FIL 34945
Zone: WOMEN
LWH: 8.0
x
8.0 x 8.0
1. DESIGN CONDITIONS - COOLING
( Jul 1700 )
Dry Bib RH
Moisture Range Wet Bib
Outdoor Conditions
89 62
15
78
Indoor Conditions --- >
75 50
63
TOD Correction --- >
2
Difference
14
61.4
Mult = 1.0 ] -
i
- 2. GLAZING SOLAR HEAT GAIN
( Lat = 27.45
ON ,
Const Wt
= M )
Type Orien Shad Tilt
%ovr Area SC
Shgf Shad
Sens
n/a 0 n/a 0
0 0.00
0 0.0
0
3. TRANSMISSION GAINS
Type Orien GrArea NtArea
Uval Grp
CLTD
Shad Clr
Sens
WALL 3 N 64
64
0.137 D
16.5
N
D 145
WALL 3 S 64
43
0.137 D
22.8
N
D 134
DOOR 3 s 21
21
0.360
13.5
-
102
FLOR 1 - 16
16
0.810
0.0
0
4. INTERNAL HEAT GAIN
Sens Latent
PEOPLE
Activity
Total
Sensible
Latent
Schedule ft'/prsn
# people
Btuh/prsn
Btuh/prsn
Restroom 50
0 1
210
140 269 179
8to6
0
0 0
0
0 0 0
wnghtsc3ft Right-Sufte Commercial 5.0.17 RSC50847 2004-Nov-0915:12:27
C:UAy Documents\Wrighlsoft HVACIPRO-SOURCE OFFICE-LUNCH.rsc Page 1
11. RETURN DUCT HEAT GAIN
Gain factor 0.00 x Line 6 Sensible Gain
12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh)
SPACE HEATING LOAD CALCULATION
13. HEATING DESIGN TEMPERATURE
Heating TD
= (Inside DB - Outside DB)
14. TRANSMISSION LOSSES
Type Expos
GrArea NetArea
Uval
WALL 3 N
64 64
0.137
WALL 3 S
64 43
0.137
DOOR 3 s
21 21
0.360
FLOR 1
16 16
0.810
0
2105 2727
( 70 - 42) =
28
Mult = 1.0 ] —
HTD
Loss
28.0
246
28.0
165
28.0
212
28.0
363
15.
INFILTRATION
Loss
695
23 cfm x db Temp Diff 28.0
x 1.10
16.
SUBTOTAL HEATING LOAD FOR SPACE
1680
17.
SUPPLY DUCT HEAT LOSS
50
Loss factor 0.03 x Line 16 Loss
18.
VENTILATION
50 cfm x db Temp Diff 28.0
x 1.10
1540
19.
HUMIDIFICATION
Inside RH desired 40.0 (Max =
32.0 for 1 pane )
# of Glazing panes 0.0 (Max =
52.0 for 2 pane )
73 cfm x 3.20 g/100cfm/d
= 2.3 gpd
878
20.
RETURN DUCT HEAT LOSS
0
Loss factor 0.00 x Line 16 Loss
21.
TOTAL HEATING LOAD ON EQUPMENT (Btuh)
4148
wnghtsoft Right -Suite Commemia15.0.17RSC50847 2004-NOV-0915:12:27
C.Wy DommentslWrightsofl HVACtPRO-SOURCE OFFICE-LUNCH.mc Page 3
Right -Suite Commercial Load Calculation
MEN
. * PRO SOURCE Job: 111612004
Project Informaltion
For: PRO SOURCE
LUNCH/OFFICE, FT. PIERCE, FL 34945
Zone: MEN
LWH: 26.0
x 11.0 x
8.0
1. DESIGN CONDITIONS - COOLING
( Jul 1700 )
Dry Blb
RH Moisture
Range
Wet ab
Outdoor Conditions --- >
89
62
15
78
Indoor Conditions —>
75
50
63
TOD Correction --- >
2
Difference
14
61.4
Mult = 1.0 ] —
2. GLAZING SOLAR HEAT GAIN
( Lat
= 27.45 °N Const Wt =
M) ,
Type Orien Shad Tilt
%ovr Area
SC Shgf
Shad
Sens
n/a 0 n/a 0
0 0.00 0
0.0
0
3. TRANSMISSION GAINS
Type
Orien GrArea
NtArea
Uval Grp
CLTD
Shad
Or
Sens
WALL
3 N 88
88
0.137 D
16.5
N
D
199
WALL
3 E 208
208
0.137 D
32.5
N
D
926
WALL
3 S 88
88
0.137 D
22.8
N
D
275
WALL
3 W 144
123
0.137 D
24.5
N
D
413
DOOR
2 w 21
21
0.360
13.5
102
FLOR
1 - 66
66
0.810
0.0
0
ROOF
1 - 182
182
0.060 R-4
67.5
D
737
4. INTERNAL HEAT GAIN
Sens Latent
PEOPLE
Activity
Total
Sensible
Latent
Schedule
ft'/prsn #
people
Btuh/prsn
Btuh/prsn
Restroom
50 0
6
210
140
1201 801
8to6
0 0
0
0
0
0 0
wnghtsc3ft Right -Suite Commerd1815.C.17 RSC50847 2004-Nov-0915:12:27
C:VvTy Oocuments=dghtsofl HVACtPRO-SOURCE OFFICE-LUNCH.mc Page 1
LIGHTS
Type
Total
Factor
Space
Schedule W/ft2
W W
Btuh/W
fract
Fluorescent 2.00
0 572
4.10
1.0
2345
8to6
Fluorescent 0.00
0 0
4.10
1.0
0
Fluorescent 0.00
0 0
4.10
1.0
0
Fluorescent 0.00
0 0
4.10
1.0
0
PLUG LOADS / APPLIANCES
Application
Usage Total Sensible
Latent
Schedule
Btuh
Btuh
Plug load W/ft2
W
8to6 0.7
0 1.00 200
3
0
683
0
#/ft2
#
0.0
0 1.00 0
0
0
0
0
#/ft'
#
0.0
b 1.00 0
0
0
0
0
#/ft2
#
0.0
0 1.00 0
0
0
0
0
#/fr
#
0.0
0 1.00 0
0
0
0
0
#/ftz
#
0.0
0 1.00 0
0
0
0
0
MOTORS
Power (hp)
Load Total Sensible
Schedule #/ft2
# factor
Btuh
0.00 0.0
0 1.00 0
0
0
0.00 0.0
0 1.00 0
0
0
0.00 0.0
0 1.00 0
0
0
5.
INFILTRATION
Sens
Latent
25 cfm ->
x db Temp Diff 13.5
x 1.10
375
->
x Moist. Diff 61.4
x 0.69
1072
6.
SUBTOTAL COOLING LOAD FOR SPACE
7256
1873
7.
SUPPLY DUCT HEAT GAIN
Gain factor 0.03
x Line 6 Sensible Gain
218
S.
COOLING FAN SIZING
Sum of Duct Gain (7 ),
Line (6) & Drawthru Fan
=
7474
(L 8
Sens ) / (Xfer x Supply
TD ) =
cfm
Est Cooling cfm = (
7474) / (1.10 x 20.0
) =
340
Actual Cooling Fan
>
=
487
9.
VENTILATION
0 cfm ->
x db Temp Diff 13.5
x 1.10
0
->
x Moist. Diff 61.4
x 0.69
0
10.
RETURN AIR LOAD FROM LIGHTING AND ROOF
Lights
Total power ( W)
0
2345
RA Roof Load
from Line 3 (+)
0
RA Ceiling Load Credit
from Line 3 (-)
0
wrlghtsoft Right -Suite Commercial5.0.17RSC50S47
2004-Nov-0915:12:27
C:Wy Documents\Waghtsoft HVACIPRO-SOURCE OFFICE-LUNCH.rsc
Page 2
11. RETURN DUCT HEAT GAIN
Gain factor 0.00 x Line 6 Sensible Gain 0
12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh)
SPACE HEATING LOAD CALCULATION
13. HEATING DESIGN TEMPERATURE
7474 1873
Heating TD
= (Inside DB - Outside DB)
_ ( 70 - 42) =
28
Mult = 1.0 ] -
14. TRANSMISSION LOSSES
Type Expos
GrArea
NetArea
Uval
HTD
Loss
WALL 3 N
88
88
0.137
28.0
338
WALL 3 E
208
208
0.137
28.0
798
WALL 3 S
88
88
0.137
28.0
338
WALL 3 W
144
123
0.137
28.0
472
DOOR 2 w
21
21
0.360
28.0
212
FLOR 1
66
66
0.810
28.0
1497
ROOF 1
182
182
0.060
28.0
306
15.
INFILTRATION
Loss
43 cfm x db Temp Diff 28.0
x 1.10
1321
16.
SUBTOTAL HEATING LOAD FOR SPACE
5280
17.
SUPPLY DUCT HEAT LOSS
Loss factor 0.03 x Line 16 Loss
158
18.
VENTILATION
0 cfm x db Temp Diff 28.0
x 1.10
0
19.
HUMIDIFICATION
Inside RH desired 40.0 (Max =
32.0 for 1 pane )
# of Glazing panes 0.0 (Max =
52.0 for 2 pane )
43 cfm x 3.20 g/100cfm/d
= 1.4 gpd
519
20.
RETURN DUCT HEAT LOSS
Loss factor 0.00 x Line 16 Loss
0
21.
TOTAL HEATING LOAD ON EQUPMENT (Btuh)
5957
wnghtsoft Right -Suite Commemial5.0.17RSC50647 20N-Nowm 15:12:27
C.XMy DooumentsUdghtsofi HVACtPRO-SOURCE OFFICE-LUNCH.mc Page 3
Right -Suite Commercial Load Calculation
GENERAL OFFICE
PRO SOURCE Job: 11/5/2004
Project Information
For. PRO SOURCE --
LUNCH/OFFICE, FT. PIERCE, FL 34945
Zorie GENERAL'OFFICE`
LWH: 25.8 x 48.0 x 8.0
1. DESIGN CONDITIONS - COOLING
Outdoor Conditions
Indoor Conditions
TOD Correction
Difference
2. GLAZING SOLAR HEAT GAIN
Type Orien Shad Tilt
GLAZ 1 S N 90
3. TRANSMISSION GAINS
(Jul1500)
Dry Bib RH Moisture Range Wet Bib
90 59 15 78
75 50 63
0
15 61.4
( Lat = 27.45 ON , Const Wt = M
%ovr Area Sc Shgf Shad
— 64 1.00 0 1.0
Type
Orien
GrArea
NtArea
GLAZ
1
S
64
64
WALL
2
N
384
384
WALL
2
S
384
299
WALL
2
W
207
207
DOOR
1
s
21
21
FLOR
1
-
122
122
ROOF
1
-
1240
1240
4. INTERNAL HEAT GAIN
PEOPLE
Activity
Schedule
Office
8to6
Uval
Grp
CLTD
Shad
Clr
1.040
14.5
N
-
0.065
D
13.5
N
D
0.065
D
15.8
N
D
0.065
D
14.5
N
D
0.360
14.5
0.810
0.0
0.060
R-4
66.5
D
Mult = 1.0 ] —
Sens
1832
Sens
965
337
307
195
110
0
4948
Sens Latent
Total Sensible Latent
ft2/prsn # people Btuh/prsn Btuh/prsn
150 0 8 250 200 2067 1653
0 0 0 0 0 0 0
wnghtsoft Right -Suite Commercial 5.0.17 RSC50847 2004-N0w0915:12:27
'C:1My Dooumems\WrigMsoft HVACIPRO-SOURCE OFFICE -LUNCH.= Page 1
-
LIGHTS
Type
Total
Factor
Space
Schedule
W/ft'
W W
Btuh/W
fract
Fluorescent
2.00
0 2480
4.10
1.0
10168
8to6
Fluorescent
0.00
0 0
4.10
1.0
0
Fluorescent
0.00
0 0
4.10
1.0
0
Fluorescent
0.00
0 0
4.10
1.0
0
PLUG LOADS / APPLIANCES
Application
Usage Total Sensible
Latent
Schedule
Btuh
Btuh
Plug load
W/ft2
W
8to6
0.7
0 1.00 868
3
0
2962
0
#/ft'
#
0.0
0 1.00 0
0
0
0
0
#/ft'
#
0.0
0 1.00 0
0
0
0
0
#/ft'
#
0.0
0 1.00 0
0
0
0
0
#/ft2
#
0.0
0 1.00 0
0
0
0
0
#Ift2
#
0.0
0 1.00 0
0
0
0
0
MOTORS
Power (hp)
Load Total Sensible
Schedule
#If?
# factor
Btuh
0.00
0.0
0 1.00 0
0
0
0.00
0.0
0 1.00 0
0
0
0.00
0.0
0 1.00 0
0
0
5.
INFILTRATION
Sens
Latent
10 cfm
->
x db Temp Diff 16.0
x 1.10
165
->
x Moist. Diff 61.4
x 0.69
425
6.
SUBTOTAL COOLING LOAD FOR SPACE
24054
9098
7.
SUPPLY DUCT HEAT GAIN
Gain factor 0.03
x Line 6 Sensible Gain
722
8.
COOLING FAN SIZING
Sum of Duct Gain
(7 ),
Line (6 ) & Drawthru Fan
=
24776
(L 8
Sens ) / (Xfer x Supply
TD ) =
cfm
Est Cooling cfm
= (
24776) / (1.10 x 20.0
) =
1126
Actual Cooling Fan
>
=
1371
9.
VENTILATION
165 cfm
->
x db Temp Diff 15.0
x 1.10
2728
->
x Moist. Diff 61.4
x 0.69
7020
10.
RETURN AIR LOAD FROM LIGHTING AND ROOF
Lights
Total power (W)
0
10168
RA Roof Load
from Line 3 (+)
0
RA Ceiling Load Credit
from Line 3 (-)
0
wnghtsoft Rlght-Suite Commemia15.0.17RSC50947 2004-Nov-0915:12:27
C.Wy Doouments\Wrightsoft WAMPRO-SOURCE OFFICE-LUNCH.rso Page 2
11. RETURN DUCT HEAT GAIN
Gain factor 0.00 x Line 6 Sensible Gain
V
12. TOTAL COOLING LOADS ON EQUIPMENT (Btah) 27504 9098
SPACE HEATING LOAD CALCULATION
13. HEATING DESIGN TEMPERATURE
Heating TD = (Inside DB - Outside DB)
_ ( 70 - 42) =
28
Mult = 1.0 ] -
14. TRANSMISSION LOSSES
Type Expos GrArea NetArea Uval
HTD
Loss
GLAZ 1 S 64 64 1.100
28.0
1971
WALL 2 N 384 384 0.065
28.0
699
WALL 2 S 384 299 0.065
28.0
544
WALL 2 W 207 207 0.065
28.0
376
DOOR 1 s 21 21 0.360
28.0
212
FLOR 1 122 122 0.810
28.0
2763
ROOF 1 1240 1240 0.060
28.0
2083
15. INFILTRATION
Loss
70 cfm x db Temp Diff 28.0
x 1.10
2144
16. SUBTOTAL HEATING LOAD FOR SPACE
10792
17. SUPPLY DUCT HEAT LOSS
Loss factor 0.03 x Line 16 Loss
324
18. VENTILATION
165 cfm x db Temp Diff 28.0
x 1.10
5092
19. HUMIDIFICATION
Inside RH desired 32.0 (Max =
32.0 for 1 pane )
# of Glazing panes 1.0 (Max =
52.0 for 2 pane )
235 cfm x 1.48 g/100cfm/d
= 3.5 gpd
1276
20. RETURN DUCT HEAT LOSS
Loss factor 0.00 x Line 16 Loss
0
21. TOTAL HEATING LOAD ON EQUPMENT (Btuh)
17484
wrrghtsoft Right -Suite Commercial 5.0.17 RSCS0847 2004-Nov-0915:12:27
C:Wy DocumemsWrlghtsoft HVACIPRO-SOURCE OFFICE-LUNCH.me Page 3
Right -Suite Commercial Load Calculation
OFFICE 2
PRO SOURCE Job: 111512004
For. PRO SOURCE
LUNCH/OFFICE, FT. PIERCE, FL 34945
Zone: OFFICE 2-'
LWH: 13.0 x 12.0 x 8.0
1. DESIGN CONDITIONS - COOLING ( Jul 1500 )
Outdoor Conditions
Indoor Conditions
TOD Correction
Difference
2. GLAZING SOLAR HEAT GAIN
Type Orien Shad Tilt
GLAZ 1 E N 90
GLAZ 1 S N 90
Dry Bib
RH
Moisture Range
Wet Bib
90
59
15
78
75
50
63
0
15
61.4
Mult = 1.0 ] —
( Lat =
27.45 ON Const Wt =
M )
%ovr Area
Sc
Shgf Shad
Sens
— 24
1.00
0 1.0
1472
— 32
1.00
0 1.0
916.
3. TRANSMISSION GAINS
Type
Orien GrArea
NtArea
Uval Grp
CLTD
Shad
Clr
Sens
GLAZ
1 E 24
24
1.040
14.5
N
-
362
GLAZ
1 S 32
32
1.040
14.5
N
-
483
WALL
1 E 104
80
0.069 D
33.5
N
D
185
WALL
1 S 96
64
0.069 D
15.8
N
D
70
WALL
1 W 1
1
0.069 D
14.5
N
D
1
FLOR
1 - 25
25
0.810
0.0
0
ROOF
1 - 156
156
0.060 R-4
66.5
D
622
4. INTERNAL HEAT GAIN
Sens Latent
PEOPLE
Activity
Total
Sensible
Latent
Schedule
ft2/prsn #
people
Btuh/prsn
Btuh/prsn
Office
150 0
1
250
200
260 208
8to6
0 0
0
0
0
0 0
wnghtsoft Right -Suite Commercial5.0.17RSC50847 2004-Nov-0915:12:27
C:1My Documents\WrIghtsoft HVA0PRO-SOURCE OFFICE-LUNCH.mc Page 1
LIGHTS
Type
Schedule W/ft' W
Fluorescent 2.00 0
8to6
Fluorescent 0.00 0
Fluorescent
0.00
0
Fluorescent
0.00
0
PLUG LOADS / APPLIANCES
Application
Schedule
Plug load
W/ft'
W
8to6
0.7
0
#/ft2
#
0.0
0
#/ft2
#
0.0
0
#/ff
#
0.0
0
#/ft2
#
0.0
0
#/ftz
#
0.0
0
MOTORS
Power (hp)
Schedule
#/ft'
#
0.00
0.0
0
0.00
0.0
0
0.00
0.0
0
Total
Factor
Space
W
Btuh/W
fract
312
4.10
1.0
1279
0
4.10
1.0
0
0
4.10
1.0
0
0
4.10
1.0
0
Usage
Total
Sensible
Latent
Btuh -
Btuh
1.00
109
3
0
373 0
1.00
0
0
0.
0 0
1.00
0
0
0
0 0
1.00
0
0
0
0 0
1.00
0
0
0
0 0
1.00
0
0
0
0 0
Load
Total
Sensible
factor
Btuh
1.00
0
0
0
1.00
0
0
0
1.00
0
0
0
5. INFILTRATION
0 cfm -> x db Temp Diff 15.0 x 1.10
-> x Moist. Diff 61.4 x 0.69
6. SUBTOTAL COOLING LOAD FOR SPACE
7. SUPPLY DUCT HEAT GAIN
Gain factor 0.03 x Line 6 Sensible Gain
S. COOLING FAN SIZING
Sum of Duct Gain (7 ), Line (6) & Drawthru Fan =
(L 8 Sens ) / (Xfer x Supply TD ) = cfm
Est Cooling cfm = ( 6204) / (1.10 x 20.0 ) = 282
Actual Cooling Fan > = 346
9. VENTILATION
21 cfm -> x db Temp Diff 15.0 x 1.10
-> x Moist. Diff 61.4 x 0.69
Sens Latent
0
0
6023 1091
181
6204
343
883
10. RETURN AIR LOAD FROM LIGHTING AND ROOF
Lights Total power (W) 0 1279
RA Roof Load from Line 3 (+) 0
RA Ceiling Load Credit from Line 3 (-) 0
wrightsoft Right-Sufte Commercial 5.0.17 RSC50847 2004-Now0915:12:27
C:1My Documents\Wrightsoft WAVPRO-SOURCE OFFICE -LUNCH.= Page 2
11. RETURN DUCT HEAT GAIN
Gain factor 0.00
x Line 6 Sensible Gain
0
' 12. TOTAL COOLING LOADS ON
EQUIPMENT (Btuh)
6547 1091
SPACE HEATING LOAD CALCULATION
13. HEATING DESIGN TEMPERATURE
Heating TD = (Inside DB - Outside DB)
_
( 70 - 42) =
28
- -
1.0 -
Mult = ]
14. TRANSMISSION LOSSES
Type Expos GrArea
NetArea
Uval
HTD
Loss
GLAZ 1 E 24
24
1.100
28.0
739
GIAZ 1 S 32
32
1.100
28.0
986
WALL 1 E 104
80
0.069
28.0
155
WALL 1 S 96
64
0.069
28.0
124
WALL 1 W 1
1
0.069
28.0
3
FLOR 1 25
25
0.810
28.0
571
ROOF 1 156
156
0.060
28.0
262
15. INFILTRATION
6 cfm x db Temp Diff 28.0 x 1.10
16. SUBTOTAL HEATING LOAD FOR SPACE
17. SUPPLY DUCT HEAT LOSS
Loss factor 0.03 x Line 16 Loss
18. VENTILATION
21 cfm x db Temp Diff 28.0 x 1.10
19. HUMIDIFICATION -
Inside RH desired 32.0 (Max = 32.0 for 1 pane )
# of Glazing panes 1.0 (Max = 52.0 for 2 pane )
27 cfm x 1.48 g/100cfm/d = 0.4 gpd
20. RETURN DUCT HEAT LOSS
Loss factor 0.00 x Line 16 Loss
21. TOTAL HEATING LOAD ON EQUPMENT (Btuh)
wnghtsoft Right -Sane Commemial5.0.17RSC50847
C:IMy Do entslWrightwft HVACIPRO-SOURCE OFFICE -LUNCH.=
Loss
192
3031
91
641
147
2004-No 0915:12:27
Page 3
Right -Suite Commercial Load Calculation
F OFFICE 3
PRO SOURCE Job: 111512004
Projoct Information
For: PRO SOURCE
LUNCH/OFFICE, FT. PIERCE, FL 34945
Zone: OFFICE 3
LWH: 13.0 x 12.0 x 8.0
1. DESIGN CONDITIONS - COOLING
Outdoor Conditions
Indoor Conditions
TOD Correction
Difference
2. GLAZING SOLAR HEAT GAIN
Type Orien Shad Tilt
GLAZ 1 E N 90
3. TRANSMISSION GAINS
(Jul 1500)
Dry Bib RH Moisture
90 59
75 50
0
Range Wet Bib
15 78
63
15 61.4
( Let = 27.45 'N Const Wt
%ovr Area Sc Shgf Shad
--- 24 1.00 0 1.0
Type
Orien
GrArea
NtArea
GLAZ
1
E
24
24
WALL
1
N
96
96
WALL
1
E
104
80
FLOR
1
-
25
25
ROOF
1
-
156
156
4. INTERNAL
HEAT GAIN
PEOPLE
Activity
Schedule
ft2/prsn.
Office
150
8to6
0
--[ Muit = 1.0 ] —
= M)
Sens
1472
Uval Grp
CLTD
Shad Clr
Sens
1.040
14.5
N -
362
0.069 D
13.5
N D
89
0.069 D
33.5
N D
185
0.810
0.0
0
0.060 R-4
66.5
D
622
Sens Latent
Total Sensible Latent
# people Btuh/prsn Btuh/prsn
0 1 250 200 260 208
0 0 0 0 0 0
wnghtsoft RightSute Commetciai5.9.17RSC50847 2004-No"915:12:27
CAMy DowmentslWtightsoft HUACIPRO-SOURCE OFFICE-LUNCH.mc Page 1
.,t
LIGHTS
Type
Total
Factor
Space
Schedule W/ft'
W W
Btuh/W
Tract
Fluorescent 2.00
0 312
4.10
1.0
1279
8to6
Fluorescent 0.00
0 0
4.10
1.0
0
Fluorescent 0.00
0 0
4.10
1.0
0
Fluorescent 0.00
0 0
4.10
1.0
0
--
PLUG LOADS / APPLIANCES
Application
Usage Total
Sensible
Latent
Schedule
Btuh
Btuh
Plug load W/ft'
W
8to6 0.7
0 1.00 109
3
0
373
0
#/ft2
#
0.0
0 1.00 0
0
0
0
0
#Ift'
#
0.0
0 1.00 0
0
0
0
0
#/ft'
#
0.0
0 1.00 0
0
0
0
0
#fft2
#
0.0
0 1.00 0
0
0
0
0
#/ftz
#
0.0
0 1.00 0
0
0
0
0
MOTORS
Power (hp)
Load Total
Sensible
Schedule #/ftz
# factor
Btuh
0.00 0.0
0 1.00 0
0
0
0.00 0.0
0 1.00 0
0
0
0.00 0.0
0 1.00 0
0
0
5.
INFILTRATION
Sens
Latent
0 cfm ->
x db Temp Diff
15.0 x 1.10
0
,
->
x Moist. Diff
61.4 x 0.69
0
6.
SUBTOTAL COOLING LOAD FOR SPACE
4643
1091
7.
SUPPLY DUCT HEAT GAIN
Gain factor 0.03
x Line 6 Sensible Gain
139
8.
COOLING FAN SIZING
Sum of Duct Gain (7)
Line (6) & Drawthru
Fan =
4782
(L 8
Sens ) / (Xfer x Supply TD ) =
cfm
Est Cooling cfm = (
4782) / (1.10 x
20.0 ) =
217
Actual Cooling Fan
> =
283
9.
VENTILATION
21 cfm ->
x db Temp Diff
15.0 x 1.10
343
->
x Moist. Diff
61.4 x 0.69
883
10.
RETURN AIR LOAD FROM LIGHTING AND ROOF
Lights
Total power (W)
0
1279
RA Roof Load
from Line 3 (+)
0
RA Ceiling Load Credit
from Line 3 (-)
0
wnghtsoft Right -Suite commercia15.0.17 RSC50847
2004-Nav-0915:12:27
C:UNy DowmentslWrightsoft HVACIPRO-SOURCE OFFICE -LUNCH.=
Page 2
'w
11. RETURN DUCT HEAT GAIN
Gain factor 0.00 x Line 6 Sensible Gain
0
12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh)
5125 1091
SPACE HEATING LOAD CALCULATION
13. HEATING DESIGN TEMPERATURE
_ Heating TD = (Inside DB - Outside DB)
_ ( 70 - 42) =
28
Mult = 1.0 ] —
14. TRANSMISSION LOSSES
Type Expos GrArea NetArea Uval
HTD
Loss
GLAZ 1 E 24 24 1.100
28.0
739
WALL 1 N 96 96 0.069
28.0
185
WALL 1 E 104 80 0.069
28.0
155
FLOR 1 25 25 0.810
28.0
567
ROOF 1 156 156 0.060
28.0
262
15. INFILTRATION
Loss
6 cfm x db Temp Diff 28.0
x 1.10
192
- 16. SUBTOTAL HEATING LOAD FOR SPACE
2101
17. SUPPLY DUCT HEAT LOSS
Loss factor 0.03 x Line 16 Loss
63
18. VENTH ATION
21 cfm x db Temp Diff 28.0
x 1.10
641
19. HUMIDIFICATION
Inside RH desired 32.0 (Max =
32.0 for 1 pane )
# of Glazing panes 1.0 (Max =
52.0 for 2 pane )
27 cfm x 1.48 gl100cfmld
= 0.4 gpd
147
20. RETURN DUCT HEAT LOSS
Loss factor 0.00 x Line 16 Loss
0
21. TOTAL HEATING LOAD ON EQUPMENT (Btuh)
2951
wrightsoft Right -Suite Commercia15.0.17RSC50847 2004-Nov-0915:12:27
C:1My Documents\Wdghtsofl HVACTRO-SOURCE OFFICE-LUNCH.mc Page 3
h Right -Suite Commercial Load Calculation
LUNCH RM
PRO SOURCE Job: 111612004
ProjkA Information
For: PRO SOURCE —
LUNCH/OFFICE, FT. PIERCE, FL 34945
Zone: LUNCH RM
LWH: 26.0 x 32.0 x 8.0
1. DESIGN CONDITIONS - COOLING ( Jul 1700 )
Dry Bib
RH
Moisture Range Wet Bib
Outdoor Conditions
89
62
15
78
Indoor Conditions
75
50
63
TOD Correction
2
Difference
14
61.4
Mult = 1.0 ] -
- 2. GLAZING SOLAR HEAT GAIN
( Lat =
27.45
ON . ,
Const Wt
= M )
Type Orien Shad
Tilt %ovr Area
SC
Shgf Shad
Sens
GLAZ 1 S N
90
— 12
1.00
0 1.0
266
3. TRANSMISSION GAINS
Type Orien GrArea
NtArea
Uval Grp
CLTD
Shad Clr
Sens
GLAZ 1 S 12
12
1.040
13.5
N
- 168
WALL 3 N 256
256
0.137 D
16.5
N
D 579
WALL 3 E 144
144
0.137 D
32.5
N
D 641
WALL 3 S 256
223
0.137 D
22.8
N
D 696
DOOR 4 s 21
21
0.360
13.5
102
FLOR 1 82
82
0.810
0.0
0
ROOF 1 - 5
5
0.060 R-4
67.5
D 22
4. INTERNAL HEAT GAIN
Sens Latent
PEOPLE
Activity
Total
Sensible
Latent
Schedule
ft2/prsn #
people
Btuh/prsn
Btuh/prsn
Restaurant
75 ' 0
11
275
275 3051 3051
8tO6
0
wrrghtsc3ft Right-SuRe Commercial '5.0.17 RSCS0847 2004.NOv 0915:12:27
C.Wy Doauments\Wrightsofl HVACIPRO-SOURCE OFFICE-LUNCH.tso Page 1
. .�
LIGHTS
Type
Total
Factor
Space
Schedule
Wff
W W
Btuh/W
Tract
Fluorescent
2.00
0 1664
4.10
1.0
6822
8to6
Fluorescent
0.00
0 0
4.10
1.0
0
Fluorescent
0.00
0 0
4.10
1.0
0
Fluorescent
0.00
0 0
4.10
1.0
0
-
PLUG LOADS / APPLIANCES
Application
Usage Total Sensible
Latent
Schedule
Btuh
Btuh
Plug load
W/ft2
W
8to6
0.7
0 1.00 582
3
0
1987
0
#/ft'
#
0.0
0 1.00 0
0
0
0
0
W
#
0.0
0 1.00 0
0
0
0
0
#/ftz
#
0.0
0 1.00 0
0
0
0
0
#/ft'
#
0.0
0 1.00 0
0
0
0
0
#/ft2
#
0.0
0 1.00 0
0
0
0
0
MOTORS
Power (hp)
Load Total Sensible
Schedule
#/ft'
# factor
Btuh
0.00
0.0
0 1.00 0
0
0
0.00
0.0
0 1.00 0
0
0
0.00
0.0
0 1.00 0
0
0
5.
INFILTRATION
Sens
Latent
10 cfm
->
x db Temp Diff 13.5
x 1.10
149
->
x Moist. Diff 61.4
x 0.69
425
6.
SUBTOTAL COOLING LOAD FOR SPACE
14483
12896
7.
SUPPLY DUCT HEAT GAIN
Gain factor 0.03
x Line 6 Sensible Gain
434
S.
COOLING FAN SIZING
Sum of Duct Gain
(7 ),
Line (6) & Drawthru Fan
=
14917
(L 8
Sens ) / (Xfer x Supply
TD ) =
cfm
Est Cooling cfm
= (
14917) / (1.10 x 20.0
) =
678
Actual Cooling Fan
>
=
960
9.
VENTILATION
222 cfm
->
x db Temp Diff 13.5
x 1.10
3295
-
->
x Moist. Diff 61.4
x 0.69
9421
10.
RETURN AIR LOAD FROM LIGHTING AND ROOF
Lights
Total power (W)
0
6822
RA Roof Load
from Line 3 (+)
0
RA Ceiling Load Credit
from Line 3 (-)
0
wnghtsoft RightSuite Commercial5.0.17RSC50847 2004-Nov-0915:12:27
C-.Wy D=mentslWAghtsoR HVACIPRO-SOURCE OFFICE-LUNCH.mc Page 2
11. RETURN DUCT HEAT GAIN
Gain factor 0.00 x Line 6 Sensible Gain
0
12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh)
18212 12896
SPACE BEATING LOAD CALCULATION
13. HEATING DESIGN TEMPERATURE
Heating TD = (Inside DB - Outside DB)
_ ( 70 - 42) =
28
Mult = 1.0 ] -
14. TRANSMISSION LOSSES
Type Expos GrArea NetArea Uval
HTD
Loss
GLAZ 1 S 12 12 1.100
28.0
370
WALL 3 N 256 256 0.137
28.0
982
WALL 3 E 144 144 0.137
28.0
552
WALL 3 S 256 223 0.137
28.0
855
DOOR 4 s 21 21 0.360
28.0
212
FLOR 1 82 82 0.810
28.0
1860
ROOF 1 5 5 0.060
28.0
9
15. INFILTRATION
Loss
53 cfm x db Temp Diff 28.0
x 1.10
1641
16. SUBTOTAL HEATING LOAD FOR SPACE
6481
17. SUPPLY DUCT BEAT LOSS
Loss factor 0.03 x Line 16 Loss
194
18. VENTILATION
222 cfm x db Temp Diff 28.0
x 1.10
6833
19. HUMIDIFICATION
Inside RH desired 32.0 (Max =
32.0 for 1 pane )
# of Glazing panes 1.0 (Max =
52.0 for 2 pane )
275 cfm x 1.48 g/100cfm/d
= 4.1 gpd
1494
20. RETURN DUCT HEAT LOSS
Loss factor 0.00 x Line 16 Loss
0
21. TOTAL HEATING LOAD ON EQUPMENT (Btah)
15003
wrrghtsoft Right -Suite Commercial 5.0.17 RSC50847 2004-Nov-0915:12:27
C:Wiy DowmemslWrlghtsofl WACTRO-SOURCE OFFICE-LUNCH.m Page 3
®STEPHEN A. BROCK
ARCHITECTS, INC.
4189 Elm Avenue
Palm Beach Gardens, FL 33410
Office (561) 622-4480 • Fax (561) 630-0784
e-mail: SABAI@bellsouth.net • License AR0006492
December 20, 2004
• Mr. Wihiam Hatcher
Plans Review Agent
St. Lucie County Building Dept.
2300 Virginia Avenue
Fort Pierce, Florida 34982
Re: Builder's First Source
Permit#124101909
Dear Mr. Hatcher:
Thank you for your time in preparing plans review comments for this project. We appreciate the
task tha, you undertake each day.
As per the comments, we have the following responses:
1. 2rdlevel office would require elevator to meetflorida accessibility code 11-4.1.2. Code
section 11-4.1.3 (5) exception 41 allows that elevators are not required if the floor area is less
than 3,000 sq. feet unless the building is a shopping mall, shopping center, or the office of a
health care provider. This facility meets the requirements of this exception.
2. . Fire sprinkler plans -table 500-factory industrial type IV unprotected. Building "A" will
have a sprinkler system and the plans are being prepared by the contractor. Building "C" is
factory industrial with an allowable area of 21,000 sq. feet unsprinkled. Area modifications allow
100% increase or a 21,000 sq. foot increase. The total allowable is 42,000 s.f and the total shown
in the plans is 41,500 s.f.
3. Travel distance length to exit — table 1004 Florida Building Code — manufacturer travel
distance to swing door warehouse from offices. The allowable distance of travel in the
manufacturing area is 250 feet in a sprinkler protected building. The distance to a required exit is
less than the maximum from any point.
4. Exits 2 d level minimum number for egress code 1004.2.2 per story 2. The drawings have
been modified to provide a maximum distance of 75 feet to a single exit per section 1004.1.2 of
the Florida Building Code.
We believe that these responses will meet with your approval. Should you have any further
questions or concerns regarding our building permit application, please do not hesitate to call on
ct
Stephen A. Brock Architects, Inc.