Loading...
HomeMy WebLinkAboutSCREEN ENCLOSURELOT 179. 9 LOT' 160' ut tea rraoFcY;eo F1'S¢)Fs ARcA�3,2aa aF.- FFE-21105 w LOT 168 a <. \4' l l aqv i COURT:60' R/W I j x�Afp LnNZ FEn rLAT)rne J;eeM1 I LEGEND PEmiFmOm. i //C ._. A"P9a R9 TnLE W9NIIMCO ,1�. C roiik�.i. VN�4PWNFEp i n - 4pm.Por. I �W _ vwr 'l.M.. mtu.[. M vhes vlre m. na Ax A M M esF6N Rrom nEta [LLURW - ".6 efJ 1nn1Vn P28CNM10Ni lot ll0 A]ONfE CAatl 0 --• i ek. nepbr COV,VmVCLUB UNRONE ov �eevtledlry m, nv......_. nnnl Fi....le.. e 9[ok Y].Pan.>R_•A II.. Pi�]n. P.mM. nI C•. \� �,__.. � oT PE 68212 M. Randall R dgers, P.E. N FL Lic. No. 68212 1801 Hazelwood Drive Fort Pierce, FL 34982 Ph: (772) 201-1634 'Surveying, Inc. REVIEWED FOR LUGAR RESIDENCE CODE COMPLIANCE ST. LUCIE COUNTY EER SCREEN BOCC FILE COPY DECK: 690 SQFf BOMBAY SCREEN ENCLOSURE PION SPA RAISED 12" ABOVE DECK 38' SPLIT LEVEL SPA BENCH IS" / 21" rn - i M H 18" : -R _ * = DECO rh 6J ,VAC,• to AIR SWITCH 21 -R a 24"SPILLWAYS DEPTH 5' 6" r o NICHELE55 SPA LED ti 18„ `\ o EDGE TILE MAIN DRAIN ��-' SPA MAIN DRAIN DEPTH 3' 6" \ A D rn n z G N y 1T 3"28 r------------ 3 6 = •6'4n 3 6 N 3 � rn _ z G /n bc::_ 12" 12' w , ti' o m tT y / rn G 3' 2.e- ,.4i EDGE TILE. Z - / rn UMBRELLA SLEEVE BUBBL R NICHEI E S POOL LED 1B" Z N UNDECK r_R / m N x -R ` i HAND L B-RTD-354 ------ --m�----------- ----------------- --- -- ---------- ------------ ---''" SKIMMER LINE 2" CHILD BARRIER TO CODE RETURN LINE 2.5" 0 DECO -DRAIN BUBBLER LINE 2" O .......................�...................._._..................................................................•.......•....................•..,.....................•........... -2 6 LEAVE 1' OFEXISTING CONCRETE ! 17' 1N 38' GRIND AND TOP EXI577NG LANAI d/- 2505QFT WATERLINE TILE: QUARZITE GREEN 6" X 611 STEP TILE: QUARZITE GREEN 1'" X 1" ACCENT TILE: 3 "SLATE" MULTI DECO ON FACE OF SPA HANDRAIL: CB-RTD-354 TAUPE .i FLO-CRETE: BOMBAY EXPANSION JOINTS: WHITE INTERIOR FINISH: SKY BLUE CHILD BARRIER:, BLACK ON BLACK PLUMB WATER FEATURES FIRST 8' 7" Shape: CIRCULAR RAISED 12" Width: 6 FT Depth: 3FT Perimeter: 19" Square Footage: 29 Material: Spillway: 2 / 24" I have reviewed and I give my approval to proceed with the construction of this project. x Customer Date MAX WIDTH: 13' 6" MAX LENGTH: 28' DEPTH: 3'6" TO S' 6" PERIMETER: 75" SHAPE: FREEFORM SQUARE FEET., 300 DIRT FROM EXCAVATION: HAUL LEAVE: NO LEAVE & SPREAD: NO LEAVE -MOVE -THEN SPREAD NO EXTRA FILL & COMPACTION NO 30B ENTRANCE: RIGHT SIDE OF HOUSE 6 X 6 TILE: QUARZITE GREEN 6" X 6" INT FINISH: SKY BLUE STEP TILE: QUARZITE GREEN 1" X 1" ON STEPS FILTER: CLEAN & CLEAR 150 PUMP: INTELLIFLO VSP MOTOR H.P. 3 HP MAX TIME CLOCK: IN PUMP CHLORINATOR: ICHLOR IC-30 LIGHTS 3 GLOBRITE, 2 POOL, 1 SPA TRANSFORMERS 2 POOL CLEANER: DORADO VAC LINE 1 MAIN DRAIN: 32" CHANNEL SKIMMERS: 1 RETURNS: 4 SWIMOUT OR LADDER: SWIMOUT HANDRAIL: CB-RTD-3S4 TAUPE FILL LINE: NONE OVERFLOW LINE: NONE SPA SPECS: 6' CIRCULAR RAISED 12" ABOVE PATIO SPA PUMP SUPERFLO 2HP SLIDE: NONE HEATER: ULTRATEMP 120c TANK: N/A VAC. HEAD: N/A VAC. HOSE 1 VAC POLE: 1 BRUSH: 1 LEAF SKIMMER: 1 TEST KIT: 1 OVERFLOW LINE: NONE FILL LINE: NONE TREE REMOVAL: NONE STUMP REMOVAL: NONE WATER & ELECTRICAL SUPPLY: REAR OF HOUSE ELECTRICAL HOOKUP: PAYUK RIGHT SIDE OF HOME BACKWASH LINE: STD BLUE FLAT LINE PATIO: 690 SQFT FLO-CRETE COLOR: BOMBAY EXISTING PATIO: 250SQFr GRIND & TOP TERMITE: STD DEC-O-DRAIN: WHITE FOOTERS: _STD PLANTERS: NONE OVERPOUR: YES SCREEN ENCLOSURE: PIONEER SCREEN "BRONZE" SAFETY FENCE COLOR: BLACK ON BLACK CUT & CAP SPRINKLERS: BY HOMEOWNER APPROX GALLONS: 9,650 PUMP G.P.M. SEE ATTACHED SOLAR BY: NONE YES 6" X 6" —X— SHEET TILE OVERPOUR —X— MOSAICS Designer: ROBERT WOOD m _X Address: 8886 S FEDERAL HWY City: PORT ST LUCIE FL 34982 Phone: 772-337-9713 ext 20 Cell: 772-631-3948BY ANNED Email: robertbwood@att.net St. Lurie Cnrintg4 License #: CPC 1458338 Name: THOMAS & DIANE LUGAR Address: 9408 PINEBARK CT City: FORT PIERCE FL 34951 Cell: 207-564-7189 MAINE HOME Email: tdlugar@gmail.com —Pool construction complies with FBC 2017 ANSI-7 ANSI-15 —Water Velocity —Max 8ft/sec as per FBC 2017—R4501.6.3 —Pool Barrier to comply with Section R4501.17-6th edition FBC —Skimmers Comply with FBC 2017—R4501.21.2 —Soil bearing capacity assumed 2,000psi @95% compaction —Equipment foundation 3'x7' conc. slab min 3.5" thick pour in place or approved Hurricane Rated precast equipment pads L1o,.+L,.. o.., ,,.,,,.ter+ I, ,.,,..,,.L, ,..I+h CQr` On17-0dr;nl WHEN PROVIIDED SHALL BE AT 20" MAX BELOW THE WATERLINE SWIMOUTS (NO SCALE) PRESSURE GAUGES INSTALLED ON FILTER PUMP FOR FINAL INSPECTION 3 Vacuum (In Hg) X 1.13 Feet Of Head c Pressure (PSI) X 2.31 Feet Of Head Vacuum Head + Pressure Head = Total Dynamic Head HYDRO -STATIC RELIEF DEVICE INSTALLED IN AREAS THAT EXCEED 1' WATER TABLE IN SHELL TRENCH DRAIN '.5- POOL SPA MAIN DRAIN POOL DETAIL (NO SCALE) OUTSIDE ANGLE OF REPOSE 6' AND FURTHER - 4" THICK WALLS W/13 REBAR e12" O.C. EACH WAY 3' TO 6• - 6" THICK WALLS W/#3 REBAR e12" O.C. EACH WAY 0' TO 3• - 8" THICK WALLS W/p(3 REBAR 012" O.C. EACH WAY UM REMOVE GRATE & WELL POINT PLUG F7UNPOURDRAIN & ATTACH AUOURONE WHEN EMPTYI6"xGRATE SHALL BE SECURED ININ PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL Y" PER FT MINN SLOPE ► OR CAR TILE APPLICABLE 6" TILE 4" SLAB TERIOR 2500 FIBER MIX FINISH 4t" TYP. WALL-3,000 PSI GUNITE STEEL-TEX FORM OR KRAFT WALL 6" TYP. FLOOR TRENCH DRAIN 3,000 PSI #3 0 12 O.C.B.W. GUNRE NOTE: FOR DEPTHS TREADED •i i` �' GREATER THAN 6' ADD PLUG :° •k (1)#3 COVE BAR ®6" O.C. GRAVEL BE TO PUMP �. TYP. WALL SECTION & WELL POINT (NO SCALE) OVERPOUR OR CAP TILE WHERE APPLICABLE 6"x6" TILE SPA BENCH 18" BELOW WATER LINE GRATE SHALL BE SECURED IN PLACE SO THAT TOOLS ARE REQUIRED FOR REMOVAL TRENCH DRAIN GRAVEL Is 6" TYP. FLOOR 6"xC TILE 4" SLAB 2500 FIBER MIX 4v" TYP, WALL-3,000 PSI GUNITE STEEL-TEX FORM OR KRAFT WALL #3 0 12" O.C.B.W. TO PUMP SPA WALL SECTION (NO SCALE) TO JET PUMP TO AIR VENT•'::; VENT LINE NOT TO BE FURTHER THAN 40 FT FROM POOL 25' MAX WET LENGTH DRAIN SPA DETAIL (NO SCALE) TO FILTER t PUMP TO AIR VENT () #3 REBAR OR POOLS (11) #5 REAR • 91 FOOTER DETAIL Y DREG, INC DECK —� 1 ROW OF WATERLINE TILE �— EE WATERLINE J CHLORINATOR HEATER FILTER 3 s MAX 5*_g11 LIGHT WALLS SHALL ;URNS PUMP W/ HAIR & LEVEL FLOOR — 11 N3 STEEL a 12" O/C E,W. 54L LINT STRAINER PUMP W/ HAIR & 6" THICK �T B RE{13 LINT STRAINER FLOOR SLOPES THAN 11 FLOOR SLOPE SHALL BE REASONABLY UNIFORM AND HEATER COMPLY WITH ARTICLES 56 I BY—PASS THRU 5.6.3 sK\MMER DUE ELOPE OF THE.AYLtOWUES c FRO S OPE ATE �E *FIE meyy,FpEO THE3WLly xWLYW END W1LLuD w III rTO THE A ILLL�M�ESos Ty � SkY AREA p • SLAI PaDE DRN\N NOT Er IN 7 FOOT EXCEED IN 7 FCE!<ErSEL1 FOOT IN 7 FO TT 2A—sAA RpOI pppM CFWANEI ORNN ClFA1'tER LINE 1 � —g CNNNNEL DRAIN MERPF't S 28'-0" PIPING SCHEM'. C TYPICAL SECTION THRU POOL (NO SCALE) CUSTOM MOLDED PRODUCTS INC. SINGE CHANNEL DUAL OUTLET CMP 25506-32X VGB PER FRC45OL6.fi COMPLIANT 32" CHANNEL DRAIN COMPLIANT W11H 2017 FLORIDA BUILDING CODE LISTED TO ASME/ANSI A112198 32" CHANNEL DRAIN AND SUMP 25506-320-000 'THREE 2" SOCKET x 2.5" SPIGOT PORTS *DEBRIS GUARD INCLUDED *38.79in? OPEN AREA *IAMPO LISTED FLOW RATES *WHITE PVC BODY *COVER GOES OVER BODY TO GIVE FINISHED LOOK TO PUMP The maximum flow rating for this suction fitting with the center port plugged and outer ports open is 308 GPM (floor) and 212 GPM (wall) when using 2.5" plumbing and 268 GPM (floor) and 192 GPM (woll) when using 2" plumbing. The maximum flow rating for this suction fitting with the outer ports plugged and the center port open is 200 GPM (floor) and 168 GPM (wall) when using 2.5" plumbing and 184 GPM (floor) and 176 GPM (wall) when using 2" plumbing.. Determine System Flow Rate: Minimum Flow Rote Required: 35 gpm per skimmer POOL 1. Calculate Pool Volume: _===__ft__=_x Z48(gol/Ft) _ _---gal PUMP (Surface Area) (Average Depth) (Volume in gallons) 2. Determine Flow Rate: ___ XXX --_ gal / _ XXX-=__XXX-__+_- XXX _ XXX Determine Pipe Sizes: (Volume) (Turnover Minutes) (Pool Flow Rate) (Feature Flow Rate) (System Flow Rate) Trunk Piping to be_ 2_5 -inch to keep velocity 0 8 fps max. at_ 117 gpm Maximum System Flow Rate. Return Piping to be_ L5 inch to keep velocity ® 8 fps max. at_ 1_17_gpm Maximum System Flow Rate, Main Drain Cover(-_ SEE_ABOVE-__--) System Flow Rate. must not exceed approved cover flaw rate. (Make and Model) See Engineering Page for Drain Configuration Pump Model PENTAIR INTELLIFLO VS3050 H.P. 3 Total H.P.=H.P.x service factor. I Kip. or more must be 2 speed Invertible speed Filter Make PENTAIR C&C Size 150 Filter min. area based on 6hr. turnover flow rate pool gal. /36o min. = Flow pate Divide G.P.M. by Cartridge = .375 w Sand =15 or D.E. = 2 Time Controller make ON PUMP Model ------ Controls must operate a minimum of two speeds. The hl herspeed override Is not to exceed one normal cycle or 24Ins. whichever Is less Pipe Slze 6 fps 8fps 1' 16 gpm 0,14' 21 gpm 0.23' 1,5' 37 gpm 0,08' 50 gpm 0.14' 2' 62 gpm 0.06' 82 aom 0,10' 2,5' 88 gpm 0.05' 17 gpm 0.09 3' 136 gpm 0.04' 181 gpm . 7' 4' 234 gpm 0,03' 313 gpm 0,05' 6' 534 gpm 0,02' 712 gpm 0,03' 3 ft. Determine Pipe Sizes: HYDROS Trunk Piping to be 2.5 inch to keep velocity ® 8 fps max. at_ 117_gpm Maximum System Flow Rate, Return Piping to be_ 2S_inch to keep velocity ® 8 fps max. at_ 117-gpm Maximum System Flow Rate. 3 ' Main Drain Cover(___ SEE_ABOVE System Flow Rate must not exceed approved cover flow rate. (Make and Model) See Engineering Page for Droin Configuration 05 Pump Model PENTAIR SUPERFLO H.P. 2 Total H.P.=H.P.x service factor 1 H.p• or more must be 2 speed or variable speed pF Filter Make N/A Size --- EXCAVATION INTO THE ANGLE OF REPOSE 15 ALLOWABLE PROVIDED: SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE Filter min. area based on Bhn turnover flow refs pool gal./360 min. =Rewrote Q$� SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT Civil by Gadridge=.375w Sand=15or D.E.=2 NO UNDERMINING OCCURS OR ENGINEER APPROVED If ANY DOES °' * Time Controller make N/A Model ------ COMPACTION TEST OF THE BACKFILLED MATERIAL ARE PROVIDED PRIOR TO THE POURING OF THE PATIO Controls must operate a minimum of two speeds. The higher Indeed override Is not to exceed one normal cycle or 24 has. whichever is lees MISC. NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 24 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR MSIBILITY 2. HANDHOLD TO BE INSTALLED ARE WHERE DECK RAISED +6" ABOVE POOL STEPS (NO SCALE) POOL PATIO WATER LEVEL 12 VAC FROM POWER SUPPLY ;.�; ;• SIZE AS DETERMINED UNDERWATER °;�:.; BY LICENSED ELECTRICIAN LIGHT '' �•,-, 1" PVC POOL FINISH CONDUIT STEP DETAILS r: j•` 1. TREAD IS MIN OF 10" WIDE. SCHEDULE 40 PVC SLEEVE 2. RISER NOT GREATER THAN 12" EXCEPT IF •, MORE THAN (3) TREADS ARE USED '.r�%, NO BONDING 3. ALL STEPS TO BE SOLID GUNITE 3000 P.S.I. •' OR GROUND A3' •! REQUIRED NICHLESS UNDERWATER LIGHT DETAIL (NO SCALE) Pipe Slze 6 fps 8fps 1' 16 gpm 0.14' 21 gpm 0.23' 1.5' 37 gpm 0.08' 50 gpm 0.14' 2' 62 gpm 0.06' 82 m 0.10, 2.5' 88 gpm 0.05' 17 gpm 0.09 3' 136 gpm 0.04' 181 gpm . 7' 4' 234 gpm 0.03' 313 gpm 0.05' 6' 534 gpm 0.02' 712 gpm 0,03' DESIGNED FOR: POOLS BY GREG LUGAR RESIDENCE 9408 PINEBARK CT FT PIERCE, FL PE 6SLA*@eNo:§ Z �801 Hazelwood' e = * ; Ft Pierce, FL34911 Z. 1*'*+ELW11R1C* `NOT INCLUDED'** PREPARED BY: STEVE HORST DRAFTING & DESIGN SERVICES (772)201.7846 horststeve@yahoo.com 12101111 1 412 PENTAIR TDH CALCULATOR Pool Information PBG-LUGAR-HIGH SPEED Flow Rate: 104.09 GPM Total Piping Lengths: Suction Lift : 2 Ft Inlet Side: 24 Ft Discharge Side: 54 Ft Maximum Pipe, Velocity Allowed: Piping Sizes: (consult your local code) Inlet Piping: 2.445 In Branch Piping: 6 FVSec Discharge Piping: 2.445 In Inlet Piping: 8 FVSec Piping Head Loss at 104.09 Gal/Min: Discharge Piping: 8 FVSec (not inruding mlings or valves) Inlet Piping: 1.60 Ft Discharge Piping: 3.60 Ft For advanced pools that contain multiple suctions, this program may be inaccurate. Consult a hydraulics engineer. This program is for single pump sytems with a single body of water. Results: Your TDH Calculation Suggested Minimum Pipe Sizes: Flow Rate: 104.09 Gal/Min Branch Piping: 3.0 In Your Head Loss: 78.91 Ft Inlet Piping: 2.51n Maximum Flow Rate Discharge Piping: 25 In at Maximum RPM: 104.09 Gal/Min Ensure the drain cover max now rating to not expended. Head Lose at Maximum Flow Rate: 76.91 Ft 1110 50 0 Selected Components Components System Head Pros. uro Ourve Intelll Flo Variable Speed. VS-SVRS, VF or VSF - 345D rpl„ Clean System Desired Operation Point 100 in ReBe.n..x Xw Oumllry +OaeaaYMln aW.LMnIL.bi 85 sitYz15"]vny valve d SSd n c-1 led rXM xMclw 12 UsTamp . 1 3x tNA Rnurn d 17 2 Piping Imtl olunma. Xa.a QaannM QuanGy edm .W.l oawln oa Vren omw 8 tx Br9 Tn inrwOn V ] pOB Pumps nl.% Va"blo Spne, Vs,svn, VF, a'ay l V6F MRNW(mNmaMrntl.Yen xB cnMdey Pomv. Mc fnlWl✓.q ksMC. Eaar1 M...T .3.1w vgeoygd+ re Wiens lledsm1'e MNMIIFhIMMaof PenleH sss'Pntl rid sye, InB. Mdbr NBBMNa1Btl Wmyanbs in Ih. ..I Smbe mNbWh., mnhpa lbNaa aepnLrnbµ M sMbW4a W ssses e.m.ybuwtlmtluz Ws-1 s,a rulusmllo 1...-.0s. aNP•aMnMeahMn IMaMWa dM»BlipMaWbYAa NFYMW xYx PttVMdSps. N,c 1MSB na'ns sgnamtf meYb Me uaMMms o,/.Wabmdn.e.mWx>nrmM. wlaMm.e. a».Bn w ma Mndnwuarylmprouup ov,onaueu.nd Bmelm. wixw,nrwe me IyN N tlwpa gauti&sYpu wa�eW pb mYu. MYW iJ M up.dWpMWWY mMkym 150 TDH CALCULATOR Pool Information PBG-LUGAR-LOW SPEED Pool Volume: 9660 Gel Total Piping Lengths: Turn Over Time: 4.25 Hr. Inlet Side: 24 Ft Suction Lift: 2 Ft Discharge Side: 54 Ft Maximum Pipe Velocity Allowed: Piping Sizes: (consult your local cede) Inlet Piping: 2.445 In Branch Piping: 6 FVSec Discharge Piping: 2.445 in Inlet Piping: A FVSec Discharge Piping: 8 FVSec P g PI in Head Loss at 37.84 Gal/Min: (not incutlNlg fittings or valves) Inlet Piping: 0.25 Ft Discharge Piping: 0.55 Ft For advanced pools that contain multiple suctions, this program may be inaccurate, Consult a hydraulics engineer. This program is for single pump sytems with a single body of water Results: Your TDH Calculation Suggested Minimum Pipe Sizes: Flow Rate: 37.84 Gal/Min Branch Piping: 2.0 In Your Head Loss: 17.36 Ft Inlet Piping: 1.5 In Maximum Flow Rate Discharge Piping: 1.51n at Maximum RPM: 104,09 Gal/Min Ensure the drain cover max flow rating is not exceeded. Head Loss at Maximum Flow Rate: 76.91 Ft 30 g 25 3 20 0 15 10 5 00 System Head Pressure Curve Nrtelli Flo Variable Speed, VO+SVRS, VF, or VSF - 1600 rpm Clean System Desired Operation Point 10 20 30 40 50 Volumetric Flow Rate (GPM) Selected Components Components x»tMam Noma quanGN mAB gays T[33']1vNv a OW M>NOreln 1 to ckanenu Deal 1 st 1.0 UIpaTM 1 1 vql Rdun O3S Piping Imo Qnmelra x.mr eB.ea xmn. qunGN aMGN 31 eB Dawm BO T. InuOn 0 T-B ] 1 0.15re 0 3 Pumps uems QuntlN IF ,,WVyO,W av¢E, VS SLURS. VF I VS ,vtwN,r,.daaxewmrMW.owMdev Pedmi mn mlbxFmo. mleacWrvno. eaerraKno rmBwr Is.swrROWa andeMSW.dm MredsI.IW lnemmkawEGVW.mada awnb. wWm PodWtlspu mn saw G>ame'al»»nW WM>mme uwdsxwWwWaM, wBMdn Unlsn BxplaaLrnaaa n.m.BBMaBMBBrwNMm»IMl may o. usedm mx dm'umanl . ...romakaesltw lh. andn"emaM MMnNswvne/¢orlhen nemns enddrzMaWld Penxv WalB/Poland $M.Inc. TM1nB MInN ntl GMBa may M lha eadmnMs W /ep'aMM VWmaela arnnse rlwdpa"sv ewun eV ma wnnmwuW urymm,pw/poM,aa eM,WAay P,MW n+,rves rM nrnlm aM/p. u.d5nnax mmodp/mrnrn. ran:eel¢.n »u.repponwBy.mµrW ELECTRICAL EQUIPMENT WIRING, GROUNDING AND INSTALLATION MUST CONFORM TO THE 2017 N.E.C. AND APPLICABLE EOCAL CODES 30" WIDE x 6'B" HIGH x 36" DEPTH CLEAR WORKING SPACE IN FRONT OF ANY PANEL BOARD PER 110.26(A), 110.26(2) AND 110,26(3) OF THE 2017 NATIONAL ELECTRIC CODE JUNCTON-BON(S) NW OF 8' DISCO CT POOL TNER W/5T ,B, ''Myi1 DECK W/P TOGGLE -SWITCH P.1. O NEC APPROVED �. I' PVC CONWR ,.....t...a` WATER PROOF CF.I. MUST NOT BE MORE 3-/12 6 MIN 20' FROM POOL 1/2' CONDUIT EDGE AND NOT WTDIM B' OF POOL EDGE 18 SOLO COPPER WRE 77 i0 EMPOTFNTVL BOND N.E.C. 2017 SEC. 680.22(3) ie SOLID COPPER WIRE TO GROUND ELECTRICAL DETAIL NOTE: ALL ELECTRICAL WORK SHALL CONFORM TO N.E.C. 2017 SEC. 080 18 SOLID COPPER SOLO WRE WITH APPROVED CLUMPS NICHE 18"MIN-24"MAX E UIPOTENTIAL BONDING DETAIL PER FLORIDA BUILDING CODE ADAPTION OF THE N.R.C. 2017 SRC, 680.26 TDH CALCULATOR Pool information PBG-LUGAR-SPA Flow Rate: 95 GPM Total Piping Lengths: Suction Lift: 2 Ft Inlet Side: 52 Ft Discharge Side: 56 Ft Maximum Pipe Velocity Allowed: Piping Sizes: (consult your local code) Inlet Piping: 2.445 In Branch Piping: 6 FVSec Discharge Piping: 2.445 In Inlet Piping: 8 FVSec Discharge Piping: 8 FVSec Piping Head Loss at 96.00 Gal/Min: (not incuding fiflingx or valves) Inlet Piping: 2.93 Ft Discharge Piping: 3.15 Ft For advanced pools that contain multiple suctions, this program may be inaccurate. Consult a hydraulics engineer. This program is for single pump sytems with a single body of water. Results: Your TDH Calculation Suggested Minimum Pipe Sixes: Flow Rate: 95.00 Gal/Min Branch Piping: 3,0 In Your Head Lose: 22.84 Ft Inlet Piping: 2.5 In Maximum Flow Rate Discharge Piping: 2.5 In at Maximum RPM: 96.00 Gal/Min Ensure the drain cover max flow rating is not expanded. Head Loss at Maximum Flow Rate: 22.84 Ft 40 30 S 0 620 Rit 10 0 0 Selected Components Components System Head Pressure Curve 2hp• Ec, Single Speed (348025) Clean System Desired Operation Point 50 100 Volumetric Flow Rate (GPM) `Z's b" L Name. quMllly 05,006MMln Pz253.,.N. 0 Goo E1m0nN 1 1. U... 4 4W Piping Inle DI»nage WMbo.,. Nema quen4N Quami, 15.00se e" smeW»sun,. a 12 ee 'yf.Tftut o ] o.e3 Pumps Nun gnmm xp, F,. smW. s».d i xaxsl 1 NI PemNrlretlamWaactby, els awn 0PenIN[mc. MlamGm&IMeµCanma Ee>.sse InINosas, Sunnesa aaaq tulle' me/pWWpugwnx>a WiUp b'afnwxa dPnveelMnr /SdaM Sp mcMwMaMx»amps+bh is elatlaasaWaabr Wunin'». vMenexeln¢lYndatl. MmsaeMauamodem»Ih.l marMa>Nln sin, NnvMMMe m!vagromOfOM nMap"n eMa,wMnlOaMIM IM1a M'nweame»nemelus Md PebMdx Mau WelMPodelqlro, iM1P#Mmb 4pbNdemeyM XN »dmaW» W rtryNmadttadm,na> W Wn mxdamlN..e.Maa"Bm Bnbunl,yl�Mm»vonvpMuna.ad+mmMe.wmm,Mnw ,IrM1! lo[Mnpa,peo0utian W1gNpp/M3a, PonNQan egMylµtcrrily Bmpbyn. \�0\111111UN// `���,, �CENS •,'p /i PE 682MRC LIC"A