Loading...
HomeMy WebLinkAboutPLANSREPAIRED STAIRS SHALL NOT CONNECT TO EXISTING RESIDENCE ST,41R FL�4N 2" x 2" 2"x2" P pickets 2" 2" x 4" of rail IV UJood iZailin EXISTING SIDE ELEVATION in Stair Info: 5 risers at 6 13/16" high 4 Treads at 11' deep SCALE 1/2" = 1'-0" 4" x 4" PT Detail scale 1/2"=l' SCOFF. OF LORK: - RF-FAIR EXISTING STAIRS S�4CK TO NEW CONDITION — NO NEL ELECTRIC NO NEW MEC�-1,4NICAL — NO NEW RLUMBING Bolt handrail tsee rail detail on this sheet o post through sppacer using 3/8" x 5" lag screw with washer in predrilled hole 4" x 4" PT wood post 2" x 6" PT graspable i type II handrail 2" x 2 " x 3.5"L ELEVATION 4" x 4" PT wood p; 2" x 2"x 3.5"L " x 6" PT graspable PLAN VIEW type II handrail Handrail Termination Detail SCALE: 1/4" = 1'-0" FRONT ELEVATION 2" x 6" PT cking screwed to iois using (2) 410 x 3" wo — screws 2" x 6" joists at 26" o.c, max — --- Bolt posts to outside joist using (1) 1/2" thrubolt Attach all posts to slab using Simpson ABU 44 post base with one 5/8" x 4" Expansion anchor into slab and filling all nail holes with 16d nails PERMITTING INFORMATION (FORM 100) Florida Building Code Residential: 5TH Edition and ASCE 1-10 for Wind Loading Building Design Is: Enclosed Risk Category: II Wind Speed: 165 mph ultimate Mean Roof Height: 15'-0" Roof Pitch: 6:2 Internal Pressure Coe icient: ±0.18 Subjectabilitg to damage from: Weathering: Negligible Termites: Vertu Heavy Width of Roof End Zone: Wind Exposure Classification: C Adjustment factor for Exposure Height Using Allowable Stress Design and Load Combination per ASCE 7-10 Section 2.4 DL+LL; DL+O.6WL; 0.61DL+0.6WL Exp Height Ad j Factor: 1.21 x Load Combo Factor 0.4 = 0.126 applied below Components III Cladding Wind Pressure (NET) Roof Zone: 1. +21.0/-33.0 psf Roof Zone: 2. +21.0/-51.0 psf Roof Zone: 3. +21.0/-84.0 psf Components @ Cladding Wall End Zone Width; 5'-6" Components t Cladding Wind Pressure (NET) Wall Zone: 4. +34.0/-39.0 psf Wall Zone: 5. +36.0/-48.0 psf Components i Cladding Wind Pressure (NET) on Garage Door: +31.0/-38.0 psf Shear Walls Considered for Structure? Yes Continuous Load Path Provided? Yes Are Components an Cladding Details Provided? Yes Minimum Soil Bearing Pressure: 2.500 psi, Presumptive: X By Test: psi This Building Shall Have the Following: APPROVED SHUTTERS: IMPACT GLASS: X BOTH: NEITHER: r OF LESS i nnm AnA PITCH HIP ROOF 2:12 TO 4i12 PITCH GABLE ROOF FROM 2:12 TO 12:12 PITCH I� = Roof Zone I EE9 = Roof Zone 2 = Corner Zones Walla Zone 4 Walls Zone 5 Roof Zone 3 END ZONE FORM 100 ONLY APPLIES TO NEW STAIRS - EXISTING RESIDENCE TO REMAIN UNTOUCHED 4" x 4" PT wood posts N 2" x PT guardrail rsee detail on this sheet II" 1 2" x pt riser and tread Bolt stringer to post using (1) 1/2" dia. thrubolt m L STAIR SECTION I" nosing required Add Simpson HGA10 strap filling all holes with 1/4' x 3" SIDS wood screws (2) 2" x 6" SYP PT ledger screwed to post using (3) U10 x 3" SDS wood screws in each board end REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC RECEIVED APR 17 2019 ST. Lucie County, Permitting SCANNED BY St. Lucie County c j v Q LN � U Q " t Q U r— LO V- LL U Q G l� v W O v N �1 +-' Q N z O QJ L L VI < Y � N W o O w� �o z > 00 o O —aQ00 sa OD 8- t- r r Q z Nci # O U r a ~ LQ v x of Jj L U N LL }' Q ,' -bd to SHEET N O� I. JOB DUMBER: j 19-17 )��, O < o�lEL R. F� 2% o° 00 AR 9770 SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" QVM1.=: i/ 7 - i -V