HomeMy WebLinkAboutPLANSGulf Coast Supply and MFG 5v Crimp Metal roofing FL 211151.12
2L ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment Installed with min. 4' side laps and V end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced V o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
12
4 1 SLOPE
•::
----------------------------------------------
5/8" thick x 8"w cut
coral finished stucco bands
LEFT ELEVATION
5/8" thick light textured
stucco on typical concrete
block construction
RIGHT ELEVATION
SCALE: 1/4" = 1'-0'
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 911651.12
26 9a. 5v crimp metal roofing attached to plywood deck using #9
wood screws with self sealing washer at 12" o.c. max spacing over
(type 2) 30 lb felt underlagment installed with min. 4 side laps
laps fastened with corrosion resistant tin caps and with 1.25" ring
spaced c.c- at all laps and two staggered rows 12" o.c. in fie
deck t trusses using attachment detail on this sheet
SCALE: 1/4" - 1'-0'
IXI
FH.
3
5/8" thick light textured
stucco on typical concrete
block construction
Ili
5/8" thick x 8"w cut
coral finished stucco bands
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, SDding Doors, windows d: Skylights
opening
Type
NOA/FL
NUMBER
Product
Model #
Manufacturer
Glass
Attachment method
T�g�"ration
Date
Design Pressure
of Approved Tests
12 3
114
FLU 11499.2
Single Hung
Series 185
Mr Windows
and doors
row • ' cor or and iwooct Issuer thro sZr"1 2.
k°ontto wl`d
filled Cflu call maintaining min 1.5 edge dstamee in strict adharonce
to the prodoct approval.
± LO pat
A
FL# 15311.1
Overhead
I
Garage Door
lodel 624/811
'-2. x IL' sex
ctional garage door
DAB
ri 'v-c w OTF ia, A Hd'w siL«. a "Mop"
�..
r °i s 'x" i i li"fr4• ee"c "a,ia aa`°ob nrntarins
q ws - o to to
+36.0/-44.0 PSF
B
FLU 16L14.1
Fiberglass
Doman Pro/
Smooth Pro
Jeld-Wan
Eko 1/4' die. tapcon with min 1.25' embedment at 3' max
from corners and 11.5' o.c. max thereafter in heed and jambs.
+ 50.0 PSF
C
FLU 16332.2
Sliding Glass
Door
Series 420
MI Windows
and doors
ai x d y�eons ens aeon ae max
T'iS'e°Cek ` r wobd fill d aMuawalllmeintelr'"anpt s f to ge istence
m strict ad�ronce to t o product approval.
+ 48.2 PSF
-
Product
NOA/FL
NUMIM
Model #
Manufacturer
Attachment Method
ration
Date
Design Pressure
of Approved Tests
Mons
FLU 15353.8
CM-18531
vertical mullion
Mi Windows
and doors
For CMy use (2) 1/4' x 2 3/4' tapcons with min 1 1/4' embedment
penetration into each Mull Clip. Attach mull to clip using (4) #10 x 1.25"
sell tapping scrams per clip as shown in product epprovsl.
+ 118.9 PSF
ROOF
FLU IIG5I.12
5V Crimp
Metal Roofing
Gulf Coast Supply
and manufacturing
2L ga. 5v crimp metal roofing attached to plguood deck using #9 x 1.5"
(t a 2) 30wlbh felt scaling washer at
with minx ,pacing sioverASTMC an
laps �!I laps
laps fastened with corrosion resistant tin c ga and with 1.25' ring Shenk nails
rced L o.c. at all laps and two staggere rows 12' o.c. in field. Attach
k to trusses using attachment dotal an roof plan
- 108.5 P$F
Siding
stucco on Block
Soffit
FLU 12198.3
Model T4 12" vented
Vingl Soffit
Kaycan
Install using 2" x 2' battens at L" o.c. screwed to soffit framing using
#8 x 3" wood screws at each truss. Install soffit to battens using
0-120 dia. x 1.5* Iona find shank mail& with 3/8" dia. head,
+55.0/-35.0 P5F
Hurricane
Panels
FI# 15014.2
24 Gauge
Storm Panels
Global Protection
Products LLC
Install using 1/2" dia. solid set lead anchor* with 1/4' dia.-20 x 1.5'
long SS screw head combo. with Neoprene washer at 12 1/2" o.c.
along the bottom and 13' o.c. at the top
+ 45.0 PSF
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record )
12
SLOPE 14
COVERED
PORCH
12
4 1 SLOPS
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
24 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12' o_c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4 side laps and L" and
laps fastened with corrosion resistant tin capa and with 1.25" ring shank nails
aced G' o.c. at all laps and two staggered rows 12' o.c. in field. Attach
eck to trusses using attachment detail on this sheet
5/8" thick light textured
stucco on typical concrete
block construction
REAR ELEVATION
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
2214 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and G" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L o.c. at all tape and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one lager of 15 lb fait using 8d nails. Substrate
to be 19/32" CDX Plgwood nailed at L" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
12
Finish Columns with
5/8" thick cut coral
finished stucco bands
2' x 4" top plate II 1/2" drgwall ceiling on trues bottom cord
1/2" drgwall on
2" x 4" studs at 14" o.c.
base -board 11 II / 2" x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
VxV #10/10 WWM on L mil Visqueen over
clean compacted termite treated fill
Interior Non-BearinQ Partition
4 1 SLOPE
III ■
A
12
5/8" thick x 8"w cut
coral finished stucco bands
SCALE: 1/4" - 1'-0'
FRONT ELEVATION
SCALE: 1/4' - 1'-0'
A
12
5/8" thick x 8"w cut
coral finished stucco bands
SCALE: 1/4" - 1'-0'
FRONT ELEVATION
SCALE: 1/4' - 1'-0'
OZIZ-
a�
oavv
o
_W U
m
W
V
U
W
J
�O�
U
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING: INFORMATION DORM 100)
Florida Building Code Residential: 6th Edition and ASCE 1-10 for Wind Loading
Buildinq Design is: Enclosed Risk Categorg: II Wind Velocity: I0 mph ultimate
Mean
Roof Height: IIII'-OO' Roof Pitch: 4:12
00,9Cr
Internal Pressure went: ±O_Is
SubJectability to damage from: Weathering: Negligible Termites: Veru Heavy
Width of Roof End Zone: 3'-f" Wind Speed: IL5 mph ultimate
Wind Exposure Classification: C
1.21 x O.L = 0.12L
Adjustment factor for Exposure Height: ASD design
Load Combination: ASCE 1-10 Section 2.4 DL+LL: DL+O.LWL: O.LDL+O.LWL
Components I Cladding Wind Pressure (NET) Roof Zone. I. +20.L/-32.6 pat
Roof Zone: 2. +20.L/-51.0 pat
Roof Zone: 3. +20.6/-a4.0 pot
Components I Cladding Wall End Zone Width: 3'-4"
Components I Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 psf
0 = Roof Zone I
Wall Zone: S. +35.8/41.8 psf
Walls Zone 4
Components I Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3Pat
Shear Walls Considered for Structure? yes
Continuous Load Path Provided?
- Roof Zone 2
®Walls
a
Zone 5
Are Components an Cladding Details Provided?Yes
END ZONE
Minimum Sal Bearing Pressure:2 500 Pal, Presumptive: X By Test: pal
SEE PRODUCT APPROVAL FOR IMPACT PROTECTION FOR OPENINGS
= Corner Zones
Roof Zone 3
ROOF LIVE LOAD: 3-1 pat ROOF DEAD LOAD: 10 pat
FLOOR LIVE LOAD: _6- ipsf FLOOR DEAD LOAD: 10 Pat
JOB ADDRESS:
FLOOR PLAN 4
CRASH POST DETAIL AREA CALCULATIONS
=
TYPICAL NOTES: SCALE I/4" I'-O"
1. Contractor t0 verify ALL notes and dimensions prior t0
34" high by 4" diameter N.T.S. Living A/C =
1,124 sq. ft.
proceeding with work.
steel crash post. Floor
Flange - Back Porch Total =
210 sq. ft.
2. Contractor to STRICTLY enforce ALL OSHA Requirements.
with 4 3/8"
expansion bolts Into Garage =
455 sq. ft.
3. ALL Lumber to be used as Beam, Rafters, etc... t0 have
slab 13/8"t 50 ksi steel plate) Front Porch Total =
96 sq, ft,
a minimum 1,400 P.S.I. fiber stress.
4. No dissimilar metals to touch.
`"91Total
=
Under Roof-
2,485 s ft.
q
S. ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
�6"
2%2"
2;6
,21,
ALL Concrete used for vertical filled cells, Cont. tie beams etc.. to
1, Total Volume = xx,xxx
sq ft.
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
,„
°
(o, Drywall at ceilings shall be leveled and attached to bottom chord
3,a
2�2"
,
of trusses with screws per FBC R-102.3.5.
p
2�
Attach buck to block mall with
-1. ALL wood In contact with concrete shall be pressure treated.
° °
1/4' dia. Elco conc screws with min.0 11/4" penetration at 12" o.c. max
Ir
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
�„ and 4" max reach corner thru
Exterior 2" x L" PT Bck
9. ALL plumbing fixtures to be low flow.
d well "
10. Contractor to Provide Drain at water heater in accordance
apes
with the current edition of the Florida Plumbing Code.
ll. Contractor to Provide a 2'-8" wide door at one bathroom for
#8 wood screws thru jamb into buck
handicap accessibility requirements.
i "
2h
i "
2�
at each tinge and 15' o.c. max and
Detail at Door prior to door attachment
12. Lowest finished floor to be set by Governing Building Department
NITS
surveyor t0 Set In field.
13. Separation between residence and garage shall be per FBC R302.6
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB, HEADER, AND
14. Door between garage and residence shall be 1-3/4"t 20 min. rated door
SILL LOCK PRIOR TO BUCK
INSTAATIWater
Heater
Install windows thru buck into
block with 3/I6' tap -con with
I I/2' penetration at L" o.c. max.
15. Wall and Ceilingshall havea flame -spread classification of not greater than 200 er FBC R3O2.9,1 from each corner and 20.' o.c. max
p
14. Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per
thereafter at jamb* and 20' o.c. max.
FBC R302.9.2 Exterior face at head and all per product approval
11. All exposed attic insulation materials installed on attic floors shall have a critical radiant
of wall Muck to be I' x 4' PT
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
Varies
materials exposed on the underside of the roof deck or on the attic walls shall comply
with F.B.C. R316 - see permit info box of code edition
18. Gyypsum board material shall conform to ASTM C36, C19, C415, C514. C630, C931
I'x4' P.T. Buck nailed to
A.0, C1002, C1041,CII11, CII-18, C1218, C1395, or C139L and shall be installed
lock with case hardened nails
Detail t w d to window attachment
according to the following: (FBC R�02.3.5)
a I n ow s prior
Masonry Beam
Drywall
Framing
Max. spacing
1" x L" P.T. Buck nailed to / NTS
block with case hardened nails
Thickness
Locution
Orientationtion
Member
fastienar
Nod sizing options for
Spacing
of
installation oP drywall into
19. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, AlU.1 and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C11-78 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall the in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompangino smoke
E developed index not to exceed 450 When tested in accordance With AA 84
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #11451.12
24ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" and
laps fastened with corrosion resistant tin caps and with 1.25ring shank nails
spaced L" c.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Simpson HETA 20 or equal
hurricane anchor et each truss
with (10) IOd x 11/2" nails
( 24" o.c.) supporting Max.
IBIOIbe. uplift `I_
Aluminum Drip
Edge iFascia /-
2" x L" Sub -Fascia
Kagcan full o vent vinlil aoffit i
using 1/8' dia shank x 15' long
roofing nails with 3/8" dia. heat
product approval -Mee chart at
5/8" thick light textured
stucco on typical concrete
block construction
#5 bar vert. w/
30" overlap
at each filled call
Grade
#1
12
4 -
TYPICAL SE
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
l ' \R-30 blown fiberglass
in bottom chord or trusses
I/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (1) 11:5 bar cunt. in each row. Substitute
precast lintel filled with concrete and (1) #5
bar cont_ for bottom row over openings
1/2' drywall over I" x furring
strips at 14" o.c, with R4.1 5-foll
insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.1
T and shall meet all pertaining ASTM codes.
io Mortar to be Type "M" only proportioned per FBC R601.1
and Mortar Jonts shall comply with FBC R401.2.1,
Provide Our-O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with concrete and
(I) #S bar vert. (typical).
Max. spacing shall not exceed
Wood 48" unless otherwise noted
Base age foundation plan notes for
spacing at openings
4" concrete slob with frbarmesh OR
L"xL" #10/10 WWM on L mil Visqueen over
clean compacted termite treated Pill
F. III01111 �IIIII;; IIII-
1I1 1II II1
14' x 14" Concrete footing
with (2) #5 bars cont. and #5
/ I O transverse bars at 48"o.c.
Scale : 1/2" = 1'-0"
Install SGD thru buck into
block with 3/16" tap -con with
1 1/2" penetration at L' o.c. max.
/from each corner and 20." o.c, max
thereafter at head per product approval
Use 3/16" tap -con with
1 1/2" penetration at L" o.c. max.
thereafter atnsill perr prooductcapproval
I" x L" P.T. Buck nailed to
block with case hardened nails
Head prior to door attachment
fixed door
sliding door
,,, Masonry Wall
11/2-7
Bottom Truck ----Tgprcal Flooring
Sill Install SGD thru buck into
block with 3/IL
e t a i l " Cap -con with
511 d 1 n Door D 1 1/2" penetration at o.c. max.
g thereafter atner aniambsdper0product approval
At Masonry Wall NITS Jamb
Window Schedule
Mark
Size
Roucih Open.
Window Descrl tion
PRESSURE ZONE
I.
4'-5%a"x V-3 %a"
54'.1x 0;41'
Single Hung
ZONE 4
2.
V-2ka"x 5'-3 W
15' x 0 %,"
single Hung
ZONE 4
3.
2'-2' x 3'-2'/2"
21h"x 38%`
Single Hung
ZONE 4
4.
3'-I' x 6'-3%"
38' x G3'/4'
Single Hung
ZONE 4
5.
4'-5y; x 4'-2 %"
54 ke'x 54 Y8"
Single Hung
ZONE 4
L.
2'-2" x 2'-2" 1
25" 24 %"
Fixed Glass -Tempered
ZONE 5
ALL Windows to be nluminum windows w/ tint
and mullions per elevations.
ALL windows to withstand pressures in permit info box on sheet 1
ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified by contractor
with manufacturers specs prior to construction
Door Schedule
Mark
Size
Rough Opening
Door Description
PRESSURE ZONE
A
9'-O" X 1'-0"
toe" x a4"
Overhead Garage Door
ZONE 4
B
3'-0' X V-8'
41' x 83
Fiberglass Panel - Inewing
ZONE 4
C
5'-0" X 6'-8"
14 x 81 �" yr hot "
I Sliding Glass Door
ZONE 4
D
2'-O' X L'-8"
Solid Core - Wood - L-Panel-Bi-Fdd Finished 24' x 81 h"
E
2'-L" X C-8"
Solid Core - Wood - L-Papal
F
3'-0' X V-8'
Surface mounted S.C. - Wood L panel over 32' drywall opening
G
2'-e" x 4'-8' x I N'
Solid Core Wood. Steel, or Maamte Door
H
2'-8" X 6'-8'
Solid Core - Wood - 4-Panel
J
X-L" X V-8"
Solid Core - Wood - L-Panel - Bi-Fold
ALL Exterior doors to withstand pressures stated in permit info
box on sheet #1
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #1
All rough opening dimensions to be verified by contractor
with manufacturers specs prior to construction
Braden t Braden AAA, PA
Architects - Planners
411
S.E. Coconut Avenue
Tel :
(112) 281-8268
Fax :
(112) 281-8283
E-mail:
bradenaiaecomcast.net
L
T
iv
tv
Winne Building Corp.
THE MANOR it
Spanish Lakes
St. Lucie County Florida
EGRESS
12'-8"
MASTER
BEDROOM
8'-O" A.F.F.
Flat Ceding
Vanity to be
�34.5" high
I I
e"
O
Rod t Shelr
�CL05ET 1�
l in
I
_ JUNIOR
m MASTER
in BEDROOM
8'-O" A.P.F.
Flat Ceiling
z
Opt. PATIO SLAB
35'-0"
21'-0"
9'-4" 12" 9'-6"
COVERED
4_-7-� PORCH
I
I
201-8"
I
1
I
GRE.1 T
ROM
S'-O" to 9' 18" A.F.F.
Vaulted Ceiling
I
I
I
I
4'-1" 15" Align cabinet
with outside
of ra', wa
�R-II Batts __
Provide Auto
Closer on Do
r - -
--
4"4 Steel Ballard 22" x 54"
See s detail on l4tLc Access i
with light
L_____-
5 2
Imp 2 CAR
ry GARAGE
Q V-4" A.F_F. R-II Bi
ling
- - - - - - - - - -
Flat Ce---
I I
I
I Block walls in Garage I
I to be struck block
I I
I 1
1 1
I I
1 I
1 I
I I
I I
I
21'-O"
vert. tied into
O
4'-3"
0
BAR TOP -
\Peia=ret
1 0 o n t1 I
(LINEN
CASINET I I
We vwte 1
I
Vanity to be KITCHEN o O
34.5" high 1 8'-0" A.F.F. O p
I Flat Cad ngg
Upper cabinets
to extend over
REF l
REP. D Q - JQ
OPlmNING - �
5 andva
Tit
O 34to to WDER 0
GEapace4. ® Wdoor I-
spc%ee NI
F i space w
in NOOK QI I
p H.B.o
5'-8" I T
tt6
8"
i HO WI
N
in a
MITo 4) o o+ri
LAUNDR
I Q
5'-O" iv 8
TEMPS H�
In line
with door 3'-10"
s to laundry
COVERED
PORCH
A
2'-8" alE 14'-0" 3'-8" II'-8" 12"
ffff 3E �
22'-4" T 12'-8"
35'-O"
MODEL: Date Drawn Revisions
GARAGE 4-2-19
LEFT Drawn bg:
C.C.U.
Checked bg:
D.R.B.
Sheet
2.
OF 5
Comm #
1B-s'4
NON-IMPAi
ZD I 1CUL.. I UlC/�L IN�J I >=.7:
1. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,600 PSI AT 28 DAYS
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 P51 OR 4,000 PSI GROUT MIX AT 28 DAYS
3. POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
4 GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ LXL 10/10
WELDED WIRE MESH REINFORCING ON L MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED. CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
5. LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL 15 BROUGHT IN. FILL MATERIAL SHALL CONSIST OF
CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL
PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE
STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND
COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY
PROCTOR VALUE.
6• GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT.
-I• GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
FOUNDATION fL.4N
IV
8. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
9. DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 4-1 PSF
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 41
EXPOSURE ="C"
10. ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A -IL, E
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 30-7 STEEL.
II, ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
12. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
13. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
14. USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1400 PSI
IS. ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
16. ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
I. Any changes to plans must be submitted to the architect
for approval before proceeding with construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified In writing for revision
4. Verify all recess thickness at showers, tile, etc....
S. Contractor to provide filled cell with concrete and 1 45 bar vert. at 48"
o.c. max. Provide (1) filled cell on each side of openings upp to 5'-11" wide.
Provide (2) filled cells on each side of openings from 6'—O" to 9'-1111
and Provide (3) filled cells on each side of openings from 10'—O" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24" o.c. unless otherwise noted (see section)
6. Contractor to provide for Form Board Survey — Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade 60, meeting ASTM A-16 and
A-35 specifications. ALL Anchors to be A-30-1 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar vert. w/
30" overlap —
at each filled cell
t�
4" concrete slab with fibermash OR
Vxk" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
I
14"w x 14"d concrete monolithic
footing with (2) #5 bar& cost.
II��I
TYPICAL FOOTING DETAIL
J SCALE 1/2" = I'-U"
4" concrete slab with fibermesh OR
61fx6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
US bar cunt.
Step per
Q foundation plan
:Y
iv :q
10" (2) #5 bars cunt. bottom steel
12"
2 DETAIL AT GARAGE STEPDOWN
SCALE 1/2" = 1'-0"
12" x 12" concrete column
block filled with concrete
and (2) #1 bars vert. tied
into lintels above Verify house slab
height in field
Top or footer
IG below finished floor
IL'
301#x30"xl6" concrete
column footing with (4)
45 bars each way
SCALE 1/2" = 1'-0"
Thicken edge to 8"x8"
with concrete and
one #5 bar continuous
#5 bar vert. w/
30" overlap
at each filled cell
Adjust curb height
based on gar. floor
slope.
#5 bar in curb \
b
SCALE: 1/4" = 1'-0"
FOOTING
SCHEDULE
Mark
size
Description
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
F
12"W
X 12"D
MONOLITHIC FOOTING
WITH (2) #5 BARS CONTINUOUS
F
30"
x 30" x IL"D
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
8"W
x e"D
THICKEN SLAB EDGE
WITH 1 #5 BAR CONTINUOUS
W
14"h
Wit
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB a 0'-0"
4" concrete slab with fibermesh OR
VxL" #10/10 WWM on 10 mil Visqueen over
fill
4" concrete slab with fibermash OR
VxG" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
err Ai-\ I
i i ii I 1�14"w x 14"d concrete monolithic
footing with (2) #5 bars cont.
Tj% GARAGE CURB DETAIL
2" x 6" IT wood secured with \
3/8"dia. x L" anchor bolt at 18" o.c.
overhead door track secured to wood
jamb per manufacturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED NTS
IN PERMIT INFO BOX ON SHEET #l. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established by the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
Filled Cell Masonry Column With One
#5 From Footing To Tie Beam
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
95 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
Braden It Braden AAA, FA
Architects - Planners
41-1 S.E. Coconut Avenue
Tel : (112) 281-8258
Fax : (112) 281-8283
OB E-mail: bradenaiaecomcast.net
Stuart. FL S4994 #AAC000032
H.B.
I® 4 I
14'-0"
i 9'-G" a 4 ' 12" 9'-9" 12"
L1+ i -- --
i —i i i i i Q© D O --- N
--�----� ------------- " I
I I 12" x 12" Concrete column 1
block Filled with concrete and
24„ p = (2) #1 bars vert. tied into
W lintels above I
f J °-
Rear Porch Slab to
I
be poured separatelg
I n 1 from House Slab. N 1
I �
Thicken Footing to I I
24"w x 14"d x 24"L I p n
I under filled cell 0 0 ©W O D 0 G
under girder bearing_
IFI L—————--——————— —
----� E
I FI Rear Patio/Slab to Fi
be flush with bottom of I
sliding door recess.
Slope I" I
I I�
I
li
r-
I
I `-
I I �-
I ,c
I Fl I
I
i
I
I I
FI 1
i
4" concrete slab with fibermesh OR I i
6"x6" 410/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill I �_
o I li
I I `-
ol I©
I I
I la
I I
I FI I
al
_i I FI 104
it
°I I
4'-O" I OE
Io
I I
M Q1
0 ----- ©-- 1•
in
I
H. 0-a"
I 44 Steel Ballard
o IQ tsus ee s�etl an
I
POanal p I I
I " 4" concrete slab with fibermash OR 1 1
O L xL11
®
n
#10/10 WWM on L mil Visqueen over I
p clean compacted termite treated fill
21'-0" I
I
I FI =
ul
o o 001
we
o
_ Q
--
W
O
W nne Buildmg Corp.
THE MANOR 11
Spanish Lakes
St. Lucie County Florida
I A -4 I
I FS 21'-0"
p— — — — — — — — — — — — — — — — — — � p 4 4
02 Recess for pp ©©--------- :'�
arage oor
IG'-O" I
22'-4"
35'-0"
MODEL: Date Drawn Revisions
14-2-19
GARAGE Drawn raven
LEFT by:
C.C.U.
Checked bg:
D.R.B.
Sheet
3).
OF 5
Comm #
I8-54
NON-IMPAi
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nall e = )
51z 8d ring shank (min. 2.5 long)
9
2. Minimum Screw Size = #8 x 2"
B. Minimum Sheathing Thickness 19/32" COX Plywood
4. Use nails or screws bas d on pressure for roof' stated
in permit info box on t ese plans for zone 3
Ke
Area
Ede
Field
Fastener
Pressure
Zone 1
6"
L"
8d ring shank
45 psf
Zone 2
4116"
8d ring shank
'i 08f
Zone 3
4 11
4"
8d ring shank
84 oaf
** Zone 3a
6"
6"
#8 wood screw
112.5 psf
** Use nails or screwsbased on pressure for r of stated
in permit info box on these plans for zone 3
Concrete
/ Lintel
Column
Verify with Plan
Provide #5 bars 48 bar
ROOF O F
FL
A
with min. provide #6 her set in pro -cast
diameters overlap into beam- Tie p
filled cell steel into continuous lintel into beam where length of
scale I/2" = l'-0"
beam block steel. the opening calls for it.
— Overhangs
— Roof pitch
at
at
1'-0" unless otherwise noted on this sheet
-f:12 unless otherwise noted on this sheet
Provide Cast -Crete
Sue-OB/OT precast
lintel act in mortar-i
Min. 8" Bearing
12"x 12"
lumn Block
Rebar
Rebar 1.48 Bar Dia.
Min. Overlap
to Lintel Attachment
NTS
r., :;
"1
Provide PT Buck
attached per jamb
"•F
details into filled cal
"
4' Pre -cast
Sill
;.:
Truss shop drawings to be provided by manufacturer
Any changes to this plan shall be submitted to the
architect for approval In writing prior to starting construction.
— ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
— Architect to review Truss Shop Drawings Prior
Poured Filled Cell to construction for layout and uplift verification
Contractor to provide for Form Board Survey and to provide
Form Board Survey to Truss Company prior to truss construction
Provide its bars with min. 48 bar
diameters overlap in filled cell. Tie
�lfilled cell steel into continuous
/ rooter steel.
. ,.: .;.: ..• ; .;.' :ear:
l ` Concrete Footing
(see factor schedule
for exact sizes)
DETAIL AT WINDOW OPENING IN
CBS WALL Scale: 1/2" = I'-0"
SINGLE PLY REAR GIRDER TRUSS
Kai 2' x 4' biockm� to Vert. leg of
truss with IOd x 1.5 nails at 4' o.c.
Install Simpson MGT into wall using
5/8' dia. threaded rod set min. I.
into stet beam and (22) IOd nails into trums
TRUSS BLOCKING DETAIL
AT GIRDER STRAPPING
AT CENTER BEARING POINT
1/8" thick light textured stucco installed per
ASTM C 924 over ASTM D type 2 paper backed
wire lath nailed to substrate through one lager of
ASTM D Type 2 felt paper using 8d Halls. Substrate
to be 19/3Z" CDX Plgwood nailed at L" o.e. in field
and edges with IOd ring shank nails into studs.
Gulf Coast Supplg and MFG 5v Crimp Metal roofing FL #11451.12
2L ga. 5v crimp metal roofing attached to plgwood deck using #9 x 1.5"
wood screws with self sealing washer at 12' oi max abating over ASTM D
(tgpe 2) 30 lb felt undarlagment installed with min. 4' side laps and L" and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet \'
Addit sal precast Lin al ,"
Lintel
Bar
ClearB
"A"
o "
• : s<
%' `� - •..�`��.
Length
Length
Span
Bars
Bars
CLEAR
2'-10"
2'-8"
1'-6"
2,#3
none
3'-4"
3'-4"
T-2"
2,u3
none
8F8-OBAT 8F8-IBAT SF8-IS/2T
;a Additional
4'-0"
3'-10"
2'-8"
2 #3
none
#5 bars
CLFAR
-4"
4'-4"
3'-2"
2,#3
none
ns Row of "H" ... .°•.-±,..'
5 -4"
5 -2n
4'-O "
2,#3
none
Block Above f::,^,•
retest Lintel '�'''�-`
2A4
none
Additional i
5'-4"
2A4
none
----e a5 bars t___-�
1'-6"
1'-0"
6'-2"
2,#5
none
8FIL-IB/IT 8FIL-IB/2T
8'-4"
I T-O"
1 2.45
none
NOTES:
ALL reinforcing steel Is grade LO.
I. min. coverage of steel-1.5"
2. min. bearing required • ea. end-8'
3. standard for remf, ateelASTM A615
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL SCHEDULE
Mark
Wln owRows
or
Unit
WI
Lintel
Size
C,�ast-Crate
specification
of
'H' Block
Above
a
Bottom
Steel
Size
Top
steel
Size
Max
Gravity
Load
(Pi
Max
Uplift
Load
(PLF)
Max
Leland
Load
(Pi
L22
2'-2'
3'—V
BF8—OB/IT
1
#5
3069
160
1024
L31
T—L'
2'-8.
Vi
4'—O"
8F8—OBAT
1
#5
2561
1363
163
L45
4'-5'
V-10'
BPS—OBAT
1
a5
1105
909
339
L60
Si
C-l'
811m8-OBAT
1
05
1236
635
'721
LLO
L'-8"
T-L"
SFS-015AT
1
#6
1011
121
534
L80
e'—O'
9'-4'
8198-1
I
a6
2
#6
162
691
612
1_90
9'-0'
10'-V
I
a6
2
#6
643
530
401
1_9015
4111
10'—V
8FIL—I5/2T
ONE
1
#6
2
#5
1633
1183
401
LI00
10'-0"
II'-4"
BF8—I15/2T
1
85
2
#5
582
494
462
LIOOS
10'-O"
II'-4"
8FIL-15/2T
ONE
1
#5
2
#6
131.1,
1028
452
L120
IT—O'
13'-4'
BF8-83/2T
1
85
2
#5
411
428
324
L120B
IT—O'
13'-4"
8FIL—I5/2T
ONE
I
#6
2
#6
1015
110
324
LI40
14'—O'
Ili'-4'
8FIL-15/2T
ONE
I
a6
2
#5
1250
Loll
269
LILO
IL'—O'
IT-4"
8198-85/2T
1
#5
2
#5
Soo
192
194
LILOB
IL'-O" 1
IT-4"
811114-6/1
ONE
I
a6
2
#6
950
Soo
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-O" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
with (10) Inrricane , x I 1/2'nails trues
( 24' o.c.) supporting Max.
1810106. uplift
Aluminum Drip
Edge t Fascia
12"
2" x V Sub-Fasci
Kagcan full o vent vinyl soffit installed
using 1/8" die shank x 15" long gals.
roofing role with 3/8' dia. head per
produce approval — see chart sheet #1
12" x 12' concrete column
block filled with concrete
and (2) #1 bare vert. tied
into lintels above
thicken edge to BOW
with concrete and
one #5 bar continuous
BEYOND
Top of Tooter
16" below finished floor
a
-1III.:i III II II III �I �I II�•—��i—�i'—
12
4
1/2'
horizontal wood
into vertical w
Aluminum Drip
Edge t Fascia
Flesh and Counter
flash
Nail ledger to
gable end truss
with (2) IOd
at each web
on 3/8" livi lath
ntal and vertical wood
r staples to provide
4" penetration into
mlfl and 3/4" penetreton
framing members
5/8' thick light textured
stucco on typical concrete
block construction
Varies - see plan
#5 bar vart. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Step per foundation plan
m
Slope per foundation plan 'r p
r
Poured Cm
concrete b
Poured Concret,
concrete block r
Concrete iii
Manufacture
Flush Mounted Shutter Detail
Uuminum Panel
izew per manufacturer
See Tggical Stud Detail
1/8" x 3/32' Wing Nut w/
perprmnnu�acturer's D r and taileeL1k9
Stud Detail
Stud w/ Du Cast Zinc lute
Nickel Plated Wing Nut
nts
Brace Gable and
with 2" x 4" SYP 382
aft back nailed to bottom
of top chords using (2) IOd
nails at each truss —
RE -ENGINEERED WOOD TRUSSES
e 24"o.c. TYPICAL
! shop drawings bg manufacturer )
\R-30 blown fiberglass
in bottom chord of trusses
drywall with smooth finish
Two rows of beam block filled with concrete
end (1) #5 bar cont, in each row. Substitute
precast lintel filled with concrete and (U #5
bar cant. for bottom row over openings
1/2" drygwall over I" x furrin
strips A AT" o.c. with R4.1 Vii
insulation on typical 8" Block walls
All drgwall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
in Mortar to be Type "M" only proportioned per FBC RLO"i
and Mortar Joints shall comply rw2h FBC RL01.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tuba etc...)
Fill cell with concrete and
(U #5 bar vart. (tgpical).
Max. abating shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
L"xV #10/10 WWM on L and Visqueen over
clean compacted termite treated fill
—14
3 T�plcal S ?ctlon at Front Force
Scale : 1/2" = 1'-0"
(3
W
Simpson HETA 20 Strap truss to wall using Simpson MGT with
hurricane anchor at each truss 5/8 dia. threaded rod with min 12" embedment
( 24" o.c.) supporting Max. into beam either wet set or in epoxy with
1810 Ibs_ uelift (:�H7F_TA 20 (22) IOd _..-
nadl gps�A into_tr_dd ��oekL% to
i1,
101
A�
WNE
I PAN
1
Ed
I•r9i
IWO,
WAFS I WA4 WA OAR
J
11
III
IWAF M NO,
NEVA
12
Cr im
-scrAwfiL_ self
at
e
laps fastened with corrosion r
cage an..
1.25" ring shank nails
IBI
spaced C o.c. at all laps andestlusm.t-!�ffra
r 0,
T.C. in field. Attach
I
Attic 'Accon
with light
111M
Imp
MEMO
Simpson HETA 20 HETA 20
hurricane anchor at each truss
( 24" o.c.) supporting Max.
1810 Ibs. uplift
Provide (2) HETA 20
straps at this locatlon
O
w
0
Fe-
w
Q
tY
Q
W
PANEL
"A"
Poles
BR
Load
Wire
Description
arc#
circ#
Description
Wee
Lood
BR
Poles
2
40
1.0 Its
#8
A/C comp
I
2
AHU
#10
3,6 ku
30
2
3
4
2
30
4.5 kw
#IO
40 gal. water HTR
5
L
Range
#L
12,0 k u
50
2
�
8
I
120
1 1.8 kw
#12
Pump
9
1 10
Drilor
810
6.0 kw
30
2
11
12
1
20
1.5 kw
#12
t3
14
Dishwasher
412
1.2 kw
20
1
1
20
1.6 kw
#12
Microwave
15
11;
Refrigerator
#12
1.2 kill
20
1
1
20
1.5 kw
$12
Kitchen S.A.C.
n
I9
Recepts
#12
-
20
1
1
20
1.9 Its
912
Kitchen S.A.C.
19
20
Recepts
#12
20
1
I
120
1 1.2 kw
#12
Clothes Washer
21
22
Recepts
#12
20
1
I
20
0.81 kw
#12
Garage Door Opener
23
24
Recapts
#12
-
20
1
1
20
1.4 kw
#12
25
2L
Recepts
#12
20
1
1
20
1.92 kw
#12
21
2a
Recepts
#12
20
1
1
16
#14
General Lighting
29
30
Recepts
912
20
1
1
Ib
#14
General Lighting
31
32
Recepts
912
20
1
1
15
-
814
General Lighting
33
34
Exterior GFCI
#12
20
1
1
16
$14
General Lighting
35
36
Bathroom GPI
#12
20
1
1
20
#12
Smoke Detectors
31
3a
General Lighting
414
15
I
1
20
#12
Bathroom GFI
39
40
General Lighting
#14
i5
I
spare
f1
42
spa e
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qt .
Watts
Total(Watts)
General Lighting. (3. watts sq, ft.)
Small Appliance. Circult(s), ...................................
.Range.........................................................
Refrigerator
Microwave.....................................................
Dish Washer
Clothes..Washer...............................................
........
Water Heater
....................................................
.ureter Pump ...................................................
.Garage,Door.Opener.................. ...
1135
3
5,205
2
1,500
3,000
1
12,000
12,000
1
1200
1,200
1
1500
1500
1
1.200
1 1,200
1
1.200
1 1.200
I
5,000
5,000
1
4.500
4.500
I
woo
1800
1
810
810
Total Watts
31,415
First 10000 Watts e100%
1
10,000
_ 10,000
Remainder 21,415 e40%
1
O
10,%L
Electric Heat or A/C 10,000 945%
1
10,000
10,000
Calculated Load
Watts
30,9L4
Voltage
240
Calculated Wattage Divided by Voltage = Total Amps 129.03
Panel Size Required = 150 Amps
Electrical S mbol Legend
$
Single Pole Switch
®
Recessed Can Light
Ss
Double Pole Switch
®
Elieball Recessed
Pe
Push Button Switch
-0-
Exhaust Fan
••e
Duplex Outlet
-�-
Ceiling Mounted Light
Special Receptacle
o-
Wall Mounted Light
ftWaterproof,
grolsid fault interruptari
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
®
Carbon Monoswde Detector
4t?
Flood Light
TQ
Thermostat
Electrical Panel
m
®
Central Vac
8
Electrical Meter
®
Smoke Detector
%f
Coiling fan
©
Television Jack
ffl
Telephone Jack
'
A/C Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
®
Speaker Hook-up
❑I
Intercom
Vent thru W L-J-
Soffif--- --
SEE MANUAL
"J" and Energg
Calculation
for Unit info
121 CFM
IOxioxt
MASTER
BEDROOM
123 CFM
IOxIOxL
14x14
B/A
EVA�-y - - - �-L 221 CFM
i IOxlOx@
ex4x4 I
CLOSET I
I
31 CFM
IOxLx4
JUNIOR
MASTER
BEDROOM Er
93 CFM
IO)dOxL
W.H.
8�-4"0 Steel Ballard
See detail on
this sheet
®= JUNCTION BOX TO SUPPORT A FAN
A/C disc.
O = THERMOSTAT LOCATION
B/A = Balanced Air
ISO
Electric Notes:
*2/0 Aluminum feed
I%*Conduit
AMP
Mcs
PANEL
I. Use copper wire only, no aluminum.
2. Provide and wire all required smoke detectors.
3. Contractor to verify location of electrical
TB
service and provider.
4. ALL paddle fans shall be on a rheostat.
AHu
S. ALL bath and kitchen receptacles to be GFI
protected.
2• PVC (FPL
L. ALL exterior outlets to be WP/GFI protected.
1. Recessed cans to be installed per NFPA requirements.
8. AFCI receptacles are required in all rooms except
Kitchen, Bathrooms, and Garage.
9. A/C Return Air Balance Must comply w/ FBC RMiL02
2• ri d service PPL
Bad #L sop , am.
to 5 cant. pZar in slab
10. A/C Refrl Brant lines that are run thru slabs must be
ev
sleeved In I YC
II ALL A/C E t h II I h I I
ELECTRICAL
RISER
2 CAR
GARAGE
12"
COVERED
PORCH
I
I
I
I
I
GREAT
ROOM
I �
221 CFM
IOxloxa
i ow 1 I
12 L 1 1
A I
4x4,` i KITCHEN
` O
\ I 16 CFM O
ko" 4" I
oD , I
- J
2mx20 ------
` 8z4CF
T ; I > OWDEF
i O
rI�22" x 64' I Q
Wttic Access
L with light - _ J L ZR _ AJ
N00
15 CFM
IOxLxs LJ
-------------------------------
I I
I I
I I
I 1
I I
I I
I I
I I
I I
I I
I I
I 1
I I
I 1
I I
I I
I I
I I
w I
48 CFM 40 FM "a
loxcx5 lox6x5
AUNDRY > I
rc
ra
COVERED
PORCH
gwpmen s a comp y wIt energy ca cis aUon ` , A LAYOUT
12. All work shall be performed by a licensed electrical -Contractor shall use AL-CU Landing lugs. NT$ I��I lr�'
contractor• the completed system shall be full operative. - Contractor shall for ue la a I A w
13.
Contractor shall pay for all fees, permits, tee ing, and
manufacturers recommendatiions which
inspections including blower testing where required.
shall be venried prior to construction
14.
All work shall be coordinated with other trades to avoid
interference with the progress of construction.
19. The electrical system shall be coin letel and effective)
y P y g
by
15.
All required insurance shall be provided for protection
grounded as required the latest edition of the N.E.C.
against the public liability and property damage for the
20, All material shall be new and shall bear underwriters'
duration of the work.
labels where applicable.
IL.
Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years from
21. All equipment and panel sizes shall be verified before
the date of acceptance or certificate of occupancy, or one
ordering. The contractor shall provide circuit routings to
year from closing sale of house.
suit the conditions.
Correction of defects shall be completed without additional
,lob
charge and shall include replacements or repair of any
22. Furnish and install all fixtures as called for on the plans
other phase of installation that may have been damaged.
or as selected by others.
11.
It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
23. All raceways and pipes placed in or through any concrete
all items for a complete electrical system and provide all
slab shall be spaced a minimum of three diameters of the
the requirements necessary for the equipment to be placed in
largest conduit or pipe from any other service.
proper working order.
18.
All work shall be done in accordance with the N.E.C. and
24. All exposed wire below T-I" shall be installed in metal EMT
shall comply with all local codes and ordinances, and shall
conduit.
meet all standard requirements of the local electric utility
and telephone company.
25. Dryer Vents to be Installed per FBC RMI502
`'.J - THERMOSTAT LOCATION SCALE: 114 " = 1'-0 It
3C 2309.1 Attic Venting Calculations
Total Attic Space = 2481 sq. ft.
Venting Ratio 1/150 = IL.58 sq. ft. required
Provide A Continuous Vented Soffit
Soffit
---- Venf, Thnu
Exhaust Duct C"4
Thru Soffit
WP
Install owlet
under disc.
not shown or
clarity
P
Opt. PATIO SLAB
MASTER
BEDROOM
TV I*N
� I
\ I
S ®Ki"', CartimI
Morwadd Detector I
Casbo
GR AT
----, RO M
/ \
Ile
WP GFCI
CGS/VERED
PIORCH
VC,I
t I
CLOS�T I
P
II
II
t`
so CFM
FAN I I
CLOSET
No -- stem
/
o
I I �n.�eombo 9
\ +IInEB ,5.1 5
I
GFCI
JUNIOR /�
�� I a
GFCI
WI
//
MASTER' / ►
I®-
�` _
G
�.
I
I
KITCHENsame i
Ln
/ 5o CFM(IC
- VL
1+40
cl
/ FAN
GFCI
yqp
I\
0
W.H.
42"h GFCI PaS
R
® r----
4"4 Steel Ballard 22" x 54'
See detail an �4ttic Access I
this sheet witfi
L_____�
Pull chain
i
150 Amp
light in attic Pp
I /
Panel
2 CAR
/NOOK
GARAGE OPTIONAL PANEL
�
LOCATION
11-�
---------- - h GFCI
--------------Garage i
1 Door
1 Opener 1
1 1
I I
I I
I i
I I
I 1
I I
I I
I I
I I
I I
I I
I I
I I
I 1
I I
ELECTRICAL PLAN
SCALE: IkV = I'-O"
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wall
LAUNDRY >w -
t,�amnimar
O s R
I I Wire For
I / - Front Post
wP GFCI Light
COVERED
PORCH
0
-Jv
U> 0
30"
Xis
W
o
,�o
4v
Post Light with
>w
Photo cell:2
) 8
Braden It Braden AlA. PA
UJ( aria Building Corp.
MODEL:
Date Drawn
Revisions
Sheet
Comm #
Architects - Planners
GARAGE
411 S.E. Coconut Avenue
Tel (112) 281-8258
1BStuart
THE MANOR 11
LEFT
Drawn by:
Drawn
F - 1
18-r4
:
C.C.U.
Spanish Lakes
Fax : (112) 281-8283
E-mall: bradenalaecomcast.net
Checked by:
NON -IMPACT
FL 34994 #AAC000032
St. Lucie County Florida
D.R.B.
OF 5
=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
.. TO DETERMINE IF MULTIPLE PLY. ,.
�- — -
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Sp n or less fJul
To U Spain
Spre er Bar '
60 degrees
or less
Tag line � 1P2 span ...
Tag line ♦r�ap3 to
p'ox2of 2pann.. w�
.pp..,
1lSp
REFER TO BCSI
REFER TO BCSI
Truss must be set this way if crane is used.
Truss must be set this way it crane is used.
Truss is an example, your truss may not match.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
Insist crane operator sets truss this way
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
A are installed. A
0
•
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
/N WARNING !\
The size of these trusses makes it necessary that they a set by a profeesional builder
familiar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
SEAT PLATES BY CHAMBERS TRUSS
Hatch 17��2/12 VAULT
It
BRIG WALL @ 8'- I
DARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPEADER BAR OF 18' - 24' IN LENGTH!!
0 Do not stand on trusses until they are braced per BCSI & properly nailed to straps and hangers .In
METAL ROOFS SHOW IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN.
3-15
u
�12
HIP CARRIER LOCATED AS DIMENSIONED ON LAYOUT
i l
rn
CORNOER JACKS
ARE NOT BEVELED.
FT
'• SEESTANDARD
\.,ENGINEERING./
p
HOO
\o
24" O.C. THRU
CORNER JACKS
ONLY 24- ' 1-1t
CORNER DETAIL
OVERHANGS NOT SHOWN FOR CIARITY
PLUMB CUT END
2X4 TOP CHORD
WALL HEIGHT 8'-1"
END DETAIL: TYPICAL
PLUMB CUT END
2X4 TOP CHORD
WALL HEIGHT 8'-1"
END DETAIL: VAULT
1J
The Architect's or Architect's representative
shop drawing approval is NOT a
"double check" of the contractor.
The contractor shall remain responsible
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
he undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authority lot
atermining successful fabrication of the trusses.
2. All dimensions in this layout have been verified by the undersigned.
3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery the
idersgned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss
tall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option.
fter 10 days of delivery remedy will be according to Florida statute 558.
4. The undersigned acknowledges receipt of 'BCSI" summary sheet by TPI & WTCA.
5. Delivery is to job site. It is the buyers responsibility to make the job site suitable for delivery. Chambers Truss has
e sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will
responsible for dump delivery only. The buyer is responsible for additional delivery expenses it Chambers Truss has
redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is
sponsible to Chambers Truss for towing costs due to site conditions.
6. Price as shown in paragraph 7 below is subject to change if any changes are made in this layout. A $50 per hour
e for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price.
voice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of
Avery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss
asonable attorney's fee for collections in event of payment not timely made. 1-112 % per month service charge will be
ided for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees
iyment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the
idersgned agrees to pay such indebtedness including attorneys fees, if default in payment for material be made by the
cipient.
10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to
:rein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida.
11. Design responsibilities are per ""National Standard And Recommended Guidelines On Responsibilities For
Dnstruction Using Metal Plate Connected Wood Trusses ANSIrrPIIWTCA 4 - 2002""
12. Warranty is per Chambers Truss Warranty attached.
A spreader bar may be required per "BCSI" to prevent Injury & damage.
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary and p ry permanent bracing are required and can save life and property
and is the responsibility of the truss erector.
Study the contents of the information packet included on delivery before
setting trusses.
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be set and square
Do not set bunks or stack of plywood, roofing material or any other
concentrated loads on trusses, this can cause collapse.
DO NOT INSTALL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
111%
NA
3105 Oleander Avenue
Fort Pierce, Florida 34982-6423
800-551-5932
Fort Pierce 772.465.2012 Fax 772.465.8711
Vero Beach 772-569.2012 Stuart 772-286-3302
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS.COM
C tlist created from this layout
This layout sent to jobsite
LOADINGIDESIGN CRITERIA REDUCIBLE
DESIGN CRITERIA
PER CODE SUCH AS SDC 1604.6.1
County
Saint Lucie County
Building Department
Saint Lucie County
Wind Design Criteria
ASIDE 2010
Wind Design Method
MWFRS(Directional)/C-C hybrid Wind ASCE 7-10
Roofing Material
Metal
Loading in PSF
Roof R.D.L. Floor
Top Chord Live
20 0
Top Chord Dead
7 4.2 0
Bottom Chord Live
-10-Non Conceurent 0
Bottom Chord Dead
10 3 0
Total Load
47 7.2 0
Duration Factor
1.25 0
Wind Speed
165mph
Top Chord C.B.
Sheathing by builder
Bottom Chord C.B.
Sheathing by builder
Highest Mean Height
15'
Building Type
Enclosed
Building Category
It: Non Restrictive
Exposure Category
C-Open Terrain with scattered obstructions
Miles from Ocean
5
Conforms to Florida Building Code 2017
R.D.L.=Restraining Dead Load
C.B.=Continuous Bracing
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
for checking field measurements and Chambers Truss Inc. Drawing Name: M11439
other construction criteria. Architect's SCALE: 1 /4" = 1 r_Or1
approval covers general roof shape,
review of truss strapping, and loading on g2 total trusses, 16 unique designs
structure from gravity and uplift loads and their r pective location Designer: BLW Reviewed by:
Approved By: —
s.
.�U17_�\dJ,,1q_S-- Date: 09/11/18 Revised 09/21/18
Date: FOR
Br en & Braden A.I.A. P.A. 1�
=+M
-7s4a9
Wynne 59 041
DESCRIPTION:
MANOR 71 / GARAGE LEFT
Page 1 of 1 CUSTOMER INITIALS EACH PAGE _
M11439
I
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qt .
Watts
Total(Watts)
General Lighting (a watts sq. ft.)
Small Appliance Circwt(s) ...
Range .. ... _ , ...... _ .......
Refrigerator
Microwave
Dish Washer
.Clothes, Washer. . ...
Clothes Dryer,
Water Heater
Garage Door Opener
Ii35
3
5,205
2
1,500
3000
1
12,000
12.000
1
1200
1200
I
1 1.500
1500
1
1,200
1200
1
1,200
1200
I
S.
5,000
1
4,500
4,500
1
810
810
Total Watts
35,615
First 10000 Watts e100%
1
10,000
10.000
Remainder 25,415 e40%
1
O
10.246
Electric Heat or A/C 10,000 945%
1
10.000
10,000
Calculated Load
Watts
30,244
_
Voltage
240
Calculated Wattage Divided by Voltage = Total Amps 126.02
Panel Size Required = 150 Am s
Electrical S mbol Legend-]
S
Single Pole Switch
®
Recessed Can Light
Double Pole Switch
®
Eyeball Recessed
Pe
Push Button Switch
Exhaust Fan
Duplex Outlet
¢
Ceiling Mounted Light
Special Receptacle
♦
Wall Mounted Light
gran fault arcwtgf
WateF interrupter
ro
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
Fc-r-1
Carbon Monoxide Detector
Flood Light
TQ
Thermostat
m
Electrical Panel
©
Central Vac
g
Electrical Meter
®
Smoke Detector
Ceiling fan
©
Television Jack
❑Z
Telephone Jack
DISCIAC
A/C Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
Speaker Hook -Up
FB = JUNCTION BOX TO SUPPORT A FAN
O = THERMOSTAT LOCATION
B/A = BALANCED AIR
X
M
C
lm I
H
z
-2-19
FIELD VERIFY SERVICE LOCATION RESPECIVE TO PANEL LOCATION AND USE APPROPRIATE RISER BELOW
A/C disc. I A/C disc.
42/0 AL SER Cable
(3) 41 THHN Copper
With 41 Grnd
2" PVC Schedule
40 conduit
2" PVC Schedule
ISO
40 conduit sleeve
AMP
AMP
MCB
into attic
MCB
PANEL AHU
PANEL i
200a rated
200a rated
meter can
meter can
ME ER
ME ER
Intersystem bonding
Intersystem bonding
2" PVC ( FPL)�
Termination point
2" PVC ( FPL)-�
Termination pant
schedule 80
schedule 80
2" rigid service FPL
2" rigd service FPL
GEC Bar�2�eL, c�peGr �uin
9a vanved
ground rods
ELECTRICAL RISER
- Contractor shall use AL-CU Landing lugs.
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
- Verify AIC/KIC Rating prior to ordering e
ELECTRIC NOTES:
GEC Bare
'I8 V G, c2ppel Wire
to alvanved
ground rods
_ ALTERNATE SERVICE ELECT. RISER
NTS - Contractor shall use AL-CU Landing lugs. NITS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall bgrtr,• Ified prior to construction
t - Verify ; XIC Rating prior to ordering equipment
Vent thru
Soffll---
123 CFM
IOxIOX4
MASTER
BEDROOM
123 CFM
IOx1OxL
12"A2"
B/Ar\
�1 ---- 10"---
9 CFM
sx4x4
CLOSET
CLOSET
14 CFM
I 8x4x4 �
Oot. PATIO SLAB
12"xl2"
B/A 223 CFM
R\ IOxlOx8
COVERED
PORCH
i:2l
223 CFM
IOxlOx8
12x12LTDWI I
B/A
9 CFMi I KITCHEN I
JUNIOR x4x4
MASTER `e I O
BEDROOM I ioXox1
I I
95 CFM O
IOxIOxL \ -- ----- J
IL 3 CFM Soffit
W.H. I 8x4x4 �----Venf�t.hTu
OWDE
r
4"m Steel Ballard - - x 54 I
See detail on i stew 1
this sheet 3 1 L Wi �i6 —
a NOO
__���- 1 I I
�150 Amp 2 C A Lc- Al A ternative IVI 15 CFM
Panel Panel 8x4x4
GARAGE Location I
w
I I 44 F a
8x4x4 8x4x4
AUNORY W I
I 1 rc h
I I o LI
I I
I I
I I
I I
I I
I I
I I
COVERED
PORCH
I I
I 1
M C�I4NICAL L/4YC
,m
I.
Use copper wire onlg from panel to devices
A T{j
15. Controctor shall guarantee all materials and workmanship
free 0 defects for a less than two From
20.
All equipment and panel sizes shall be
verified before
2.
Provide and wire all required smoke f Carbon
period of not years
ordering. The contractor shall provide
circuit routings to
Monoxide detectors.
the date of acceptance or certificate of occupancy, or one
suit the job conditions.
3.
Contractor to verify location of electrical
year from closing sale of house.
service and provider.
Correction of defects shall be completed without additional
21,
Furnish and install all fixtures as called
For on the plans
4.
ALL bath and kitchen receptacles to be GFCI protected.
charge and shall include replacements or repair of any
or as selected by others.
5.
ALL exterior outlets to be WP/GFCI protected.
other phase of installation that may have been damaged.
L.
Recessed cans to be installed per NFPA requirements.
IL. It is not the intent of these plans to show every minor detail
22�
All raceways and pipes placed in or through any concrete
T
Tamper resistant AFCI receptacles are required in
of construction. The contractor shall furnish and install
slab shall be spaced a minimum of three diameters of the
ALL rooms.
all items for a complete electrical system and provide all
largest conduit or pipe from any other
service.
S.
A/C Return Air Balance Must comply w/ FBC RMI402
the requirements necessary for the equipment to be placed in
9.
A/C Refrigerant lines that are run thru slabs must be
proper working order.
23.
All exposed wire below 9'-l" shall be
installed in metal EMT
sleeved in VC conduit.
10. ALL A/C Equipment shall comply with energy calculation Il. All work shall be done in accordance with the N.E.C. and
II. All work shall be performed b a licensed electrical shall comply with all local codes and ordinances, and shall 24. Dryer Vents to be installed per
P 9 meet all standard requirements of the local electric utility FBC RM1502
contractor, the completed system shall be Fully operative, and telephone company.
12. Contractor shall pay for all Fees, permits, testing, and
inspections including blower testing where required. 18. The electrical ayatem shall be completeiy and effectivelg
13. All work shall be coordinated with other trades to avoid grounded as required bg the latest edition of the N.E.C.
interference with the progress of construction.
14. All required insurance shall be provided For protection 19. All material shall be new and shall bear underwriters'
against the public habilitu and orooertu damage For the labels where applicable.
�y��,1;
SCALE: 1/4" = 1'—V,11
Attic ventino Calculations FBC 2309.7
Total Attic Space = 2,481 sq. ft.
Venting Ratio VISO = ILS8 sq. ft. required
Provide A Continuous Vented Soffit
Exhaust Duct ry
Thru Soffit , -
4" Exhaus
Duct Thru
Wall
WF
Install owlet
under disc.`/"
not shown or
clarity
F.LF.CTF-,,IC
SCALE: 1/4" = I'-O"
Post Light with
Photo cell\
r
Exhaust Duct
Thru Soffit
Wire For
Front Post
Light
Braden It Braden AAA. FA
Architects - Planners
411 S.E. Coconut Avenue
UJynne Building Corp.
THE MANOR
MODEL:
GARAGE
Date Drawn
5-24-18
Drawn by:
Revisions
II-15-18 Window 44 M.O.
$-16-o Poe.-r ftrucs
Sheet
Comm #
Tel : (112) 281-8258
LEFT
IMPACT
C.C.U.
SCANNED
F.
Fax (112) 281-8283
�
E-mail: bradenaia comcast.net
Spanish Lakes
Checked by:
BYfB
St"LucleCounty'%
Stuart FL 34994 #AACOO0032
St. Lucie County Florida
)] R. E3
OF 5