HomeMy WebLinkAboutA.M.ENGINEERING - TESTING PAPERWORKA. M. ENGINEERING AND TESTING, INC. 590 N.W. MERCANTILE PLACE PORT ST. LUCIE, FLORIDA 34986 LOCAL OFFICE: (772) 924-3575 FAx: (772) 924-3580 REPORT OF STEM WALL BACKFILL COMPACTION Client: Izzo Builders, Inc. 1338 Southwest Biltmore Street Port St. Lucie, Florida 34983 Site: 703 Northeast Ramie Court Port St. Lucie, St. Lucie County, Florida Stem Wall Backfill (Slab Area) SCANNED BY St I I Iris rni mtv Report Date: October 15, 2007 Project No: 07-1567 Lab No: Permit No: Density tests and Hand Cone Penetrometer (HCP) readings were made in the stem wall backfill (slab area) to a depth of one foot at a minimum of three locations. Density tests were performed in the upper one foot of fill. HCP readings were.taken in hand auger boreholes at one foot intervals from slab grade through the depth of fill. At the time of our testing no information was available regarding the foundation setbacks. The density tests were performed in general compliance with ASTM D 2922. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative density of subsurface soils. Density Test No. Date Tested Location Elevation feet Dry Density s Percent Com action In Place Proctor 1 10/15/07 Northeast Comer 0-1 1 108.6 113.4 95.8 2 Center Area 0-1 109.4 113.4 96.5 3 Southwest Comer 0-1 109.3 113.4 964 _ Ali elevations are below slab grade. In the locations and depths that were tested, the stem wall backfill (slab area) has been compacted to a minimum of 95 percent of the modified Proctor maximum dry density (ASTM D 1557). Distribution: Client - 3 SLC B g. e t. - D W NUjs Submitted by: A. M. ENGINEERING ND TESTING, INC. �i, 71 i' 7 on Id W. Moler, P.E. Florida Registration No. 60675 IlServer-amelcompanylC.O.D. JobsU=o Builders. A607-1567 - 703 NE Ramie Court, PSL -Stem wall BF.doc t A. M. ENGINEERING AND I1,STING9 INC. 590 N.W. MERCANTILE PLACE PORT ST. LUCIE, FLORIDA 34986 � LOCAL OFFICE: (772) 924-3575 FAx: (772) 92I -350C E+ IVE I AUG ;1U 2007 � REPORT OF STEM WALL Client: Izzo Builders, Inc. 1338 Southwest Moore Street Port St. Lucie, Florida 34983 Site: 703 Northeast Ramie Court Port St. Lucie, St. Lucie County, Florida Stem Wall Footing COMPACTION St. Lucie County Report Date: August 27, 2007 Project No: ---- Report No: 07-1476 Permit No: 0703-0014 Density tests and Hand Cone Penetrometer (HCP) readings were made below footing grade to a depth of one foot at a minimum of three locations. At the time of our testing no information was available regarding the foundation setbacks. The density tests were performed in general compliance with ASTM D 2922. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative density, of subsurface soils. z Density Test No. Date Tested Location Elevation (feet) Dry Density ct) Percent Compaction In Place Proctor 1 8/24/07 North Footing, Center 0-1 109.5 113.5 96.5 2 Fast Footing, Center 0-1. 110.6 113.5 97.4 3 South Footing, Center 0-1 109.1 113.5 96.1 4 West Footing, Center 0-1 111.1 113.5 97.9 * All elevations are below bottom of footing. ? In the locations and depths that were tested, the soil beneath the footings has been compacted to a minimum of 95 percent of the modified Proctor maximum dry density (ASTM D 1557). Additional compaction tests are required for the stem wall backfill beneath the slab. a Distribution: Client (3) SLC Bldg. Dept. (1) PCM/ah Reviewed by: A. M. ENGINEERING AND TESTING, INC. 1? )']/D7 Paul C. Martin, P:E.' ' Florida Registration No. 65051 Inrver-amelcompanylCO.D. JobsUzzo Builders, Inc107-1476- 703 NERamie Court, PSL -Stem wall footing.doc • r A. M. ENGINEERING AND TESTIING,,INC. 590 N.W. MERCANTILE PLACE PORT ST. LUCIE, FLORIDA 34986 LOCAL OFFICE: (772) 924-3575 FAx: (772) 92 S -C F��jE AUG 2 7 2007 REPORT OF STEM WALL FOOTING COMPACTION Client: Ino Builders, Inc. Report Date: August 27, 2007 1338 Southwest Moore Street Project No: ---- Port St. Lucie, Florida 34983 Report No: 07-] 476 Site: 703 Northeast Ramie Court Permit No: 703 0 A Port St. Lucie, St. Lucie County, Florida Stem Wall Footing Density tests and Hand Cone Penetrometer (HCP) readings were made below footing grade to a depth of one foot at a minimum of three locations. At the time of our testing no information was available regarding the foundation setbacks. The density tests were performed in general compliance with ASTM D 2922. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative density of subsurface soils. Density Test No. Date Tested Location Elevation (feet) D Density.(pcf) Percent Compaction In Place I Proctor 1 8/24/07 North Footing, Center 0-1 109.5 113.5 96.5 2 East Footing, Center 0-1 110.6 113.5 97.4 3 South Footing, Center 0-1 109.1 113.5 96.1 4 West Footing, Center 0-1 111.1 113.5 97.9 * All elevations are below bottom of footing. In the locations and depths that were tested, the soil beneath the footings has been compacted to a minimum of 95 percent of the modified Proctor maximum dry density (ASTM D 1557). Additional compaction tests are required for the stem wall backfill beneath the slab. Distribution: Client (3) SLC Bldg. Dept. (1) PCM/ah Reviewed by:, A. M.GINEERING AND TESTING, INC. Paul C. Martin, P.E.,. - Florida Registration No. 65051.' .J, Merver-amelcompanylC.O.D. JobsUzzo Builders, 1ncIO7-1476 - 703 NE Ramie Court, PSL -Stem wall footing.doc