Loading...
HomeMy WebLinkAboutDESIGN CERTIFICATION - WIND LOAD COMPLIANCESt. Lucie County FILE COPY.,;,: Building and Zoning Department 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-1553 Design Certification for Wind Load Compliance This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for building permits involving the construction of new residence (smglq or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply tointerior renovations (provided that no structural walls, columns or other similar component is being effected) and certain otherminor building. permits. For further assistance, please contact the Building Inspection Office at 462-1553 or 462-2172. Project Name 1'Q or a 'a N --Office Use Only , Street Address CAK Permit Number Al &,Vft2Occupancy T Construction T _y Certification Statement: I certify that, to the best of my knowledge and'belief, tlie'se plans and specifications have been designed to comply with the applicable structural portion ofthe Building Codes currently adopted and enforced by St. Lucie County. I also certify that structuual.elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. 1 Design Parameters and Assumptions Used: a check or complete the nate box.) 1. Florida Building Code 2004 Edition ASCE 7-98 2. Building Design is (check one) Enclosed Partially Enclosed Open Building 3. Building Height: 2 -7 1_ 4. Wind Speed Used in Building Design: r ys ' 3 second gust -5. Wind Exposure Classification (refer to exposure tables in Building Code identified in Line #1): C 6. Average Wind Velocity Pressure on Exterior Faces of Structure V6 -.$6 PSF 7. Peak Wind Velocity Pressure on Exterior Faces of Structure S 3. « PSF &.Importance/Use Factor (obtain from Building code): /1 O 9.Loads: Floor 'SS PSF Roofidead 95 -PSF Roof/live PSF 10. Were Shear Walls Considered for Structure (check one): Y NV o (if No, attach erplanation) 11. Is a Continuous Load Path Provided (check one): Yes No (if No, attach explanation) 12. Are Component and Cladding DetailProvided (check one): Yes ZNo _(if No, attach explanation) 13. Minimum Soil Bearing Pressure: 2000 PSF As witnessed by my seal, I hereby certify that the information included A this certificatiou is true and correct, to the best of my knowledge and belief. {� Name: �z /]% M _ 1'A'E RMAAI. I" Certification #: ��G S qO [Seal Here] Design Firm:, A aoD Date: C / a SLCCDV Form 0 020-00 rev.1015;05 ding