Loading...
HomeMy WebLinkAboutENGINEERING PAPERWORKkr Engiiueeriug & Cor[sttuction Services, inc. Civil - Structural Engineering Consulting & Construction Services EREFTVE$000 4834 South US Hwy 1 �OFort Pierce, FL 34982 A2 7 2006_ giLucie (772) 46sa068 40(772) 468-7061 Fax o� St. Lucie Q Department Building'& 2300 Virgin January 17, 2006 Development �r 1066 P.erM I I- -ff— *, MMNWM Re: Townhouse Restoration, 914 000 d 1002 Shore Winds Drive, Fort Pierce, FL 34949. To Whom it may concern, The construction drawings for the above noted projects specifies the use of a fabricated joist hanger to support the Parallam beam at the edge of the second floor overhang (see Typical End Wall Section and Typical End Wall Bracket Detail). However, during the restoration process, the contractor requested the use of a pre -manufactured joist hanger. Based on review of the design documents and applicable loads at the location in question, it was determined that the use of joist hanger HUC412 (manufactured by Simpson -Strong Tie Company, Inc.) is an acceptable alternate. The hanger is to be secured to the concrete wall with (16) - 3/16" dia. Tapcons x 1 Y2." long and to the wood beam with (6) 1 Od galvanized nails. The undersigned Consultant Certifies that the above request is acceptable and meets the intent of the original design and the Florida Building Code 2004 provided the installation is in accordance with the above instructions and hanger manufacturer's recommendations. The undersigned Consultant makes no warranty either expressed or implied, as to his findings, recommendations, specifications or professional advice except that these were developed to the best of his professional ability in accordance with generally accepted engineering practices. Should you have any questions or require additional information, please contact me at your earliest convenience. JFV/ GC Shirley Properties.Ltrmpd Sincerely, Jose F. Vazquez P.E-. President ' S;n � s • � _ a' cT1l QF !qL •. Engineeihng & Construction Services, Pit. Civil - Structural Engineering Consulting & Construction Services 4834 South US Hwy 1' Fort Pierce, Fl- 34982 (772) 468-7068 (772) 468-7061 Fax January 17, 2006 SCANNED St. Lucie County BY Department of Community Development St. L 61p, CCUAv Building & Zoning Division 2300 Virginia AveBKJ tt c�ir� pD0 PZrvn v7 ti 51�•-(�S l L� b58� Fort Pierce, FL 34982 Re: Townhouse Restoration, 91 100 and 1002 Shore Winds Drive, Fort�ierce, FL 34949. To Whom it may concern, The construction drawings for the above noted projects specifies the use of a fabricated joist hanger to support the Parallam beam at the edge of the second floor overhang (see Typical End Wall Section and Typical End Wall Bracket Detail). However, during the restoration process, the contractor requested the use of a pre -manufactured joist hanger. Based on review of the design documents and applicable loads at the location in question, it was determined that the use of joist hanger HUC412 (manufactured by Simpson -Strong Tie Company, Inc.) is an acceptable alternate. The hanger is to be secured to the concrete wall with (16) - 3/16" dia. Tapcons x 1 ''/z" ` long and to the wood beam with (6) 10d galvanized nails. The undersigned Consultant Certifies that the above request is acceptable and meets the intent of the original design and the Florida Building Code 2004 provided the installation is in accordance with the above instructions and hanger manufacturer's recommendations. The undersigned Consultant makes no warranty either expressed or implied, as to his findings, recommendations, specifications or professional advice except that these were developed to the best of his professional ability in accordance with generally accepted engineering practices. Should you have any questions or require additional information, please contact me at your earliest convenience. V Jose F. Vazquez, P.E. President JFV/ GC Shirley Properties.Urmpd