Loading...
HomeMy WebLinkAboutPLANSi I I ........„.., COVERED PATI❑ : .................. 1 0 :1 `o .......... ..... WOMEN'S a :::::: V MEWS UNIT B C = C — -- _ ... �.....� : � _ _ ;,.•� REVERSE 1 �: 1 ::: =; Cws :::::::::......... cws _ UNIT B1 3 ::::::-- 4 �..._. ............. i' 4R .. R :CWS C c 3 _ a C C SS:, 2'•.. i 3 y�::::0:'r.1- .. _ 1 CWR U u 3' 3 0 6' 31. CWR ................... .. 4' — .. .................. ...... .... .. .. CWR 4' .. ..... ....... 6' 6' 6' 6' UNITA ..............:: 3 CWR 3' ..., _ 3' CWR�� �+r.GNR.......... ..... CWR 5 cws cC s��+.M G.... - ti� cws cws ........... .1-112, .... . CWR ................ �� CWR :.. ... - ............................... ;e /r 1 CWS W53, BUILDING FLOOR PLAN — GROUND AND lie•=I1-a° •................ FIRST FLOOR .................. CWR op—cws CONTINUE TO COOLINGrp,,EK. Y�vuw SEE DETAIL SHEET AC-11 1 LOCATION OF RISERS SHOWN FOR CLARITY, COORDINATE EXACT LOCATION WITHIN WALLS ON FLOOR ABOVE. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS. LOCATION OF COOLING TOWER, CONDENSER WATER PUMPS & BOILER. SEE SHEET AC-I1 FOR 1/4' SCALE DR�IWING, VERIFY LOCATION WITH OWNERS AGENT. SCANNED BY St. Lucie Cou* V) z 0 w Q CD (PI OD 0 o.'. o z U z _ 0 o d F Q o w O_ Q U G = CL 0 Cl) 0 0 z1 J U C' F---I U LU U Q z Q U () > W � = LU LIJ o 0 pa z z Q _ w ULLJ L� Q U 3 ry 0 U U U ~o 0 v¢ U o O z r 1 J � w w V) 0 BUILDING FLOOR PLAN - GROUND AND FIRST FLOOR AC-2/ 1/8"=1'-0" LOCATION OF RISERS SHOWN FOR CLARITY. RISERS SHALL BE WITHIN FIRE RATED CHASE SUPPLIED AND INSTALLED BY OTHERS, TYPICAL FOR SHEETS AC-2 THRU AC-4. V) z O w ly- o f-- s M OD T o z U o z I, �, N Q LLJ O W 1- J Q U ?: U LLJ O_ Q U o _ a (n 0 U z n Q U I ---I z Q U = Z a U Q W � o W LL.I W ry = 0 W () o E �o o U w z EQ U J V / Z E:l Q (Y CQ L F- = tail lD U of O A B C n E F G H I J K L Mco LLJ z UNIT B2 UNIT B2 c c REVERSED cws cws 3 4 11 UNIT Bl CWR CWR UNIT B1 wsE 3 a cs i E� 1 REVERSED CWR \ CWR 5 UNIT A UNIT A REVERSED C 1 R TO c DRYER 1 CWR EXH, 6 CWs CWs 6 4• DtA. TO 4' DIX TO DRYER EXH. DE DRYER EXH. DE 1 i +• DIA. TO 4• DIA. TO DRYER EXH. cn 4' DRYER VENT \ / 4' DRYER VENT THR WALL W/ WALL C WALL W/ WALL C LL- L BACKDRAFT R. L BACKDRAFT D R. MMJNT ! 6' MOUNT Q 6' AF Li BUILDING FLOOR PLAN - FLOORS 2 THROUGH 9 m A3 1/8' = 1'- 0' o z U w cn o z 0 w Q r, o �- S � p U O � Z Q � U � m C� O H Q � W � Q U CC S z Q n� L� Q U H z Q U W � U a Q = Z — W H � � W O > W � C� _ = W o O MM� � p � � o U w � o � � z � QQ = v¢i LL U � o � 4 BUILDING PL❑❑R PLAN - IOTH PL❑❑R AC-4/ 1/8"=1'-0" Uv� �jm( cn z O w o � U n� O Q > C) cFJ � ti O U O Q S w Q� Q U _ a. 0, V) O U z Q n Q � U Q z z < Q w (__) U W _ �Q U) ry O � pa z z Q LLi 0 u (� Q LJ w LL- ry 0 Ljj Q O DUCTLESS CHEMFAN NOTES: 1. RETURN AIR THROUGH FALL LOUVER DOOR 2. FOR DRYER VENTS AND COND. WATER PIPING, SEE SHEETS AC-1,2,3,4,10 & 11. ( TYP. FOR SHEETS AC-5 THRU 8 ) UNIT "A" A/C PLAN AC-5 � 1 /4"=19-0" DUCTLESS CHEMFAN BY OTHERS (TYP. FOR ALL) DUCTLESS CHEMFAN BY OTHERS (TYP. FOR ALL) NOTES: 1. RETURN AIR THROUGH FULL LOUVER DOOR 2. FOR DRYER VENTS AND COND. WATER PIPING, SEE SHEETS AC-1,2,3,4,10 & 11. ( TYP. FOR SHEETS AC-5 THRU 8 ) UNIT "A" REVERSE A/C PLAN 1/4 12=11-opl DUCTLESS CHEMFAN z O Ld D- 0 Ld 0000 O z r w- a; Z N Q U U r DO 0 O F- Q LJ O' Q U 0' S 0_ 0 1 co I c U (-3 z Q z Qo Q w w i _1 U V) n > w U (w Q o ��0 Q Q LL m z LLJ o0 Q o !vu / n U J 1-- cn o ::) W z Q _D u o Ln uz L w W cn o DUCTLESS CHEMFAN V ( * DENOTES 10th FLOOR ONLY ) NOTES: RETURN AIR THROUGH FULL LOUVER DOOR UNIT "B1" A/C PLAN 1/4 #$-13-011 DUCTLESS CHEMFAN DUCTLESS CHEMFAN ( * DENOTES 1Oth FLOOR ONLY ) NOTES: RETURN AIR THROUGH FULL LOUVER DOOR UNIT "B1" REVERSE A/C PLAN 1/4 )$=i'-o py DUCTLESS CHEMFAN 0 z 0 w 0 w m z 0. tl h0 Z V) Q U Lli o Q m U W U W a� Q U G _ D_ 0 (n 0 U U z Q z 0 Q Q0 w un > w U � o _ \v� I- Q ry o m z �_ Lv U) o m r o w W LLJ U " J �::D 0 m Z Z Q J = V) U crf O LL- �a DUCTLESS CHEMFAN I :ter BALCONY MASTER BEDROOM LIVING ROOM CLOSET * 14X8 * 250 CFM 12X8 190` CFM * 8.0 �R K7.0 i� ,OXB 75 CFM DINING ROOM * 9"0 _ 8.0 SX4 30 CFM \•) * 0 6.�/. 0ilj� * 14xe * 200 CFM 14X6 150 CFM BEDROOM FOYER 4 * 14X8 * 200 CFM f 14X6 150 CFM DRESSI G- T4e.01 -,*"r 8X4 40 CF f� 1 BX4O[ 25 CFM BATH $ lTCC"H KIEN * 80 6"0 � f *,2X12 * 250 CFM 12X10 190 CFM D ( * DENOTES 10th FLOOR ONLY ) NOTES: RETURN AIR THROUGH FULL LOUVER DOOR UNIT "132" A/C PLAN 1/4 tp=l tolp DUCTLESS CHEMFAN DUCTLESS. CHEMFAN BALCONY MASTER BEDROOM 14X8 * 200 CFM * 14X6 ` f 50 CFM R\ �DRESSING 4- .nc, BX4 0 CFM O8X4 25 CFM BATH LIVING ROOM CLOSET 1 14XB * 4"0 7.0 250 CFM * 4 12X8 N 190 CFM 0 * 7 00 00 \ KITCHEN 8.0 6"0 12X12* a250 CFM 12x10 D7 190 CFM 1ox8 75 CFM a DINING ROOM/ 9"o * 1 BATH 30 CFM O FOYER ( * DENOTES 10th FLOOR ONLY ) 7"0 6.0 L �14X8 * 200 CFM 14X6 150 CFM BEDROOM NOTES: RETURN AIR THROUGH FULL LOUVER DOOR UNIT "B2" REVERSE A/C PLAN 1/4 "—1 '—oll DUCTLESS CHEMFAN cn z 0 w D_ 0 w 00 O z N s u Do 0 F- a 3: w 0- a C) D- _ D 0 U7 0 U z Q z — o Q Q 0 _J LL.I U w a w U wQ \ L Q �0 Q LL m Z Ld o m ry o LLJ U J '�'^^ V I 0 V I m Z z a� Q = vai D U 0 DUCTLESS CHEMFAN DUCTLESS CHEMFAN NOTES: RETURN AIR THROUGH FULL LOUVER DOOR UNIT "A" PENTHOUSE A/C PLAN (10th FL ONLY AC-8 1/4 YP=i I -of$ DUCTLESS CHEMFAN DUCTLESS CHEMFAN NOTES: RETURN AIR THROUGH FULL LOUVER DOOR UNIT "A" PENTHOUSE REVERSE A/C PLAN (10th FL ONLY 1/4 IY=i'-o )I i U7 z 0 U7 LLJ D_ 0 W � s- ZZ L U O z �= � Q U Ld o `U a m o w D_ Q U D_ _ z 0 h c- 0 U Q W Z _o u� � � LLJQ LLJ _U (/) _ > LLJ ry W o z z cf)� n Qo mz LiJ cn o Q cnQ Iz o DLLJ � J /� v, o v / m z z Q� Q Z ai) c U 0 o � (2) 'C PLAN 04 o\M cn z 0 w ly- o w co 0 z rc� q, OZ Q U � o Li O M Q m �= w Q U _ = p Cn U U Z c 0 � 0 W w z U wJ Q > W � Q �C, �- v rya i �- _ Q , m Z o Q (.nQ w V) U r p w / /� v , n V / J /y�� W Q Q J _m z 0 g� Z cn U o CD uz w w cn o 1" UP TO VENT ABOVE ROOF :HE-42 GPM 1" UP TO VENT ABOVE ROOF UP TO VENT ABOVE ROOF :-C�14 3" 1-1/4" 1-1/4" 1Oth FL-- -- -- --- 3" 2-1/2 HE-34 HE-27 9 GPM 7.1 GPM 2" 1-1/2" 9th FL -- --m -- --- 3" 2-1/2 HE-34 HE-27 9 GPM 7.1 GPM 2" 2" 8th FL -- -- -- --- 2-1/2" 2-1/2 HE-34 HE-27 D GPM 7.1 GPM 2-1/2" 2„ 7th FL -- -- -- --- 2-1/2" 2-1/2 HE-34 3rr q1A 9 GPM 2-1/2" 2-1/2" 6th FL -- -- -- --- 2-1/2" 2" 5th FL -- 4th FL - - 3rd FL - - 2nd FL -m 1st FL -- a 9 CPL-J 2-1 /2" 2-1 /2"--< HE-34 D GPM 2-1/2" 2.. -� 9 GPM 3" HE-34 9 GPM 3" --- 3"-< UP TO VENT ABOVE ROOF 1" IEG-PIM4 UP TO VENT ABOVE ROOF 3" 1-1/4" > 2-1/2" 3 0 7.1 GPM C.}- 2-1/2" - - me � - - 2„ HE-27 7.1 GPM 2-1/2" 2" HE-27 7.1 GPM 2-1/2" - - - - 1-1/2" HE-27 7.1 GPM 3" HE-27 3'- 7.1 7 OPM \` 3" 4" 3" IG 7 1-1/2- 2-1/2' HE-27 7.1 GPM 2" 2-1/2 HE-27 7A GPM 2" 2-1/2' HE127 7.1 GPM �}- 2-1/2" 2-1 /2". HE-27 7.1 GPM C ]- 2-1/2" 2„ >-1rr UP TO VENT „ ABOVE ROOF 1 ABOVE ROOF 3" UP TO VENT 3" 7.1 GPM 2-1/2" ----- 2" HE-27 7.1 GPM C,>- 2-1/2" MEN -l--- HE-27 7.1 GPM 3" HE-52 3" 13.0 GPM VROON3---- 6" 4" 1" 1'• UP TO VENT „ UP TO VENT „ HE-34 ABOVE ROOF 1 D HE-34 ABOVE ROOF UP TO VENT UP TO VENT 9 GPM ABOVE ROOF 9 GPM ABOVE ROOF 3" 3" 71 OPM 1-1 /2" MEN �m--- 2-1/2" HE-27 7.1 GPM 2" 2-1/2" HE-27 7.1 GPM 2" --- 2-1 /2"- HE-27 7.1 GPM - 2-1/2" - - - 2-1 /2"- HE-27 I 71 WM C^� 2-1/2- 2-1/2' HE-27 I 7.1 GPM L� 2-1/2" -r•----- mom -- 2" - HE-27 7.1 GPM C4>- 2-1/2- ME - MEN �- 2" - HE-27 I 7.1 OPM 3" NO "_ 6" 3" 2-1/2" � HE-27 7.1 GPM 1-1/2" < HE-27 7.1 GPM 2" < HE-27 7.1 GPM 2" < NO - - - - - - • 2-1/2" HE-27 3„ 7.1 GPM 2-1/2- < MEN 2" I HE-27 7.1 I GPM L}- 2-1/2" < 2" HE-27 I 7.1 GPM 2-1/2" < 3rr� 13.0 T-[CPM H - 3" 6" CONDENSER WATER RISER NTS 2" IHE127 7., GPM C- 2-1/2" '�- - - 1-1/2" HE-27 7.1 GPM 3" - ON MEN - 1-1 /4" HE-27 3" 7.1 GPM 3" - - - - 6" 6" ccw.Dj �r.Tt< RGgF rmJjrseanu,-1 REAJikKEAAFJATS U/(T"H P.I)3FIAI(a S `r iEM WSTALLEJL ;T'Y PiCAL) 1'• UP TO VENT HE-42 ABOVE ROOF 11 GPM 3" 1-1/4" 3" HE-34 9 GPM 2" 'm `NNNNNR�77 3" 9 GPM 2" 2-1/2" DE3M4 2-1/2" 2-1/2" 9 GPM 2-1/2- 2-1/2- 2-1/2" HE-34 9 GPM I 2-1/2" 2" ----- C:' I HE-34 9 GPM 3" 9 GPM 3" T 6" OR NO mmNRNRR 3"... < - -- - FROM TOWER 6" 6 TO TOWER �1,, z _O C7 W o ago O z �� � i Uj H z U -0 U o F- ¢ m 3 L.1 w a. o (0 m U LLJ cf) U Z Q 0 Q o cr- w W LL w U (n F- 0 O >- w � Q m LLJ o z V)o D w w ww U ��/-� o J z V / Q Q J m z O _ c) U uOf O L 1-1/4" FROM CONDENSATE SUMP PUMP, CONNEC- TOWER BASIN. TCWS 6 ROOF 10th FLxl3x13 - 9th FL —I- EF-4 L---- 27X19X19 J 19X13; - — - — - — - — - — i COOi AI ➢A Y1x3F PEAIETfLAT101! �E1JUI K,EME.l:f1S W ITT( V4r FWCi -4 SYSTEM IMSTa Ll Ek (TYPICAL) ," UP TO VENT ABOVE ROOF -----.ommm --_----- 7------w7r_7-- 8th FL —I--f— I--t------ 7th FL — - 0X13X13- 6th FL — - -- V) Z 0 (n w r- T o W o s 0 u Z " a �'�'7 U m w 7 O H Q � W a- 0 u) 0 0 Z7X19XI9 —� 19X13XI3 - — - — - - - — - — - 0 5th FL -- ---- 1 N II II 4th FL —I --+-----I-- --- 1-1 /4"- 1-1 /2"— V V V L I Y V 1 V♦ L I\ 24 —0 1-1/2"— TYPICAL N 4" DRYER EXHAUST FOR ALL N DUCT. (TYPICAL) L�l PROVIDE 2 TAPS EACH FLOOR. L IaX13X13 2nd FL 6" FROM ENLARGED COOLING TOWER DETAIL EF-1 1 /4'=1'-0' TYPICAL 4" DRYER EXHAUST TYPICAL iv 4" DRYER EXHAUST FOR ALL DUCT. (TYPICAL) FOR ALL DUCT. (TYPICAL) ACCESS PANEL (TYP)-- ►- 13X9X9 13X9X9 (- 1-1 2"— - — m- 1stFL ---------------------- -�--- DE DE DE C 1 2 3 1 DRYER EXHAUST RISERS TYPICAL CONDENSATE RISER Q�til1 NTS NTS U Z Q 0 U_ � > Ld Lv � o � W p i Qw m Z w O (%) Q (f) U cy p C) LLJ Ld U U 0 D J LLJ m Z / n v / > _ = cn H O 0 z W w V) Q o SLAB ABOVE , SPRING HANGERS 3/4' EMERG. DRAIN ROUTE OVER NEAREST SINK OR AS DIRECTED r 2' MINIMUM —y L 1 AC-12 5 AC-12 I / I I I COOLING I FAN I COIL I I I I I I 1 I I I I I 1 -� I I I I AC UNIT I I 1 SUSPENDED AIR CONDITIONING UNIT EMERG. DRAIN PAN DETAIL N.T.S. END BEARING 4' MIN DUCT TAKE OFF BRANCH _� MANUAL DAMPER MATH LOCKING TYPE INDICATOR QUADRANT ( AS REQUIRED ) 3/8' SQ ROD 1/3 W, 4' MINIMUM 45' SUPPLY DUCT AIR FLOW OR RETURN DUCT AIR FLOW SUPPLY & RETURN BRANCH CONNECTION N.T.S. JUM DU' lI N6 L FLASttILUa ) Ec1<- -- 2EJ3�A I f MEA17S W I rN 20047I0L' SYsrEgn 1 "STALL _w- TYP. ROOF EXHAUST FAN N.T.S. 3/8' ALL THREADED ROD AUXILIARY DRAIN PAN 3' MINIMUM 4' CHANNEL SUPPORT 3/4' CONDENSATE LINE -� CEILING �-----TERMINATE DIRECTLY CABOVE SINK OR CHROME PLATE AS DIRECTED 2 EMERG. CONDENSATE DRAIN AC-12) N.T.S TURNING VANE WITH SHEET METAL SCREW FASTENER'. 6 AC-12 10 AC-12 ELBOW N.T.S. 1Q CONDENSATE FROM BUILDING (J5 CONDENSATE RETURN TO COOLING TOWER Q CONDENSATE PIT COVER © SUMP TANK 03 CONDENSATE SHUT-OFF VALVES CONDENSATE PUMP ( SUBMERSIBLE WITH BUILT IN FLOAT SW. AND CONTROLLER. ) ® CHECK VALVE CONDENSATE SUMP DETAIL N.T.S. BLACK STEEL PIPE TO NEW UNIT THREADED VALVE BLACK STEEL NIPPLE THREADED BLACK STEEL FLANGE GASKET SCH. 80 SUP PVC FLANGE PVC PIPE MAKE UP WATER LINE TYPICAL PVC TO STEEL 3 PIPE CONNECTION 4 COOLING TOWER MAKE-UP & DRAIN AC-12 N.T.S. AC-12 N.T.S. :ONN. OUT PLUG of TCH 1 yr I R„r 7 DRAIN PAN TRAP DETAIL AC-12) N.T.S. HEAT PUMP SUPPLY RETURN HOSE 0 CONDENSATE DRAIN HOSE tO UNION RETURN FLOW —up SUPPLY FLOW CONDENSATE FLOW TO DRAIN O2 TEMPERATURE / PRESSURE TEST PORTS O3 FLOW REGULATOR k VALVE ASSEMBLY 8 IN -LINE STRAINER k VALVE ASSEMBLY 5 'P' TRAP 11 HEAT PUMP PIPING CONNECTION AC-12 N.T.S. n L--- GAS FIRED BOILER Q 2 STAGE TEMPERATURE CONTROL 2� THERMOMETER RETURN TO COOLING TOWER TO COOLING TOWER BASIN AND CONDENSER PUMP INLET FACTORY MOUNTED PUMP Q3 BALANCING VALVE CONDENSER WATER a BOILER CONNECTION DETAIL AC-12 N.T.S. OGATE VALVE OSUCTION DIFFUSER (TACO 348) NOT REQUIRED 3/4" GATE VALVE W/ 3 HOSE ADAPTER, SEAL CAP AND CHAIN OEXPANSION JOINT END SUCTION PUMP O CONCENTRIC REDUCER O OPRESSURE GAUGE OCHECK VALVE 12 END SUCTION PUMP DETAIL AC-12 N.T.S. Ln z O w 0_ o L � u O -0 Z Z Ld O F Q 3:: W 0 � 0 U Z Q 0 Q Of O U_ J ,wn V / \ / LLJ LIJ Q Z Ln 0 0 Q m Z W (� O U� 0 � LLJ Ld U 0 Q U) 0 ::D J Q J m Z w C G I- = can U of O 0 owt , JOIN FLEX DUCT TO FITTING IN ACCORDANCE W/MFG'S INSTRUCTIONS FLEXIBLE DUCT TAKEOFF N. T. S. HEAT PUMP SCHEDULE AREA SERVED CFM O.A. CFM ESP VOLT FLA FAN HP GTH MBH SENS. MBH EAT I EWT LWT GPM PD FT. EER COP HTG MBH MFG. MODEL # REMARKS DB I WS APT. A TYP. 1145 NA 0.3 208-10 16.3 1 3 31.8 26.7 95 9.0 13.9 10.6 4.0 44.0 FHP HEV34-1 1,2 APT. A 10TH FL 1350 NA 0.3 208-10 19.4 1 2 38.4 31.8 95 11.0 8.2 10.4 4.1 55.3 FHP HEV42-1 1,2 APT. 81,82 TYP. 875 NA 0.3 208-10 12.5 1 4 25.2 20.7 a 95 7.1 18.0 10.8 4.1 36.4 FHP HEV27-1 1.2 APT. Bi B2 10TH FL 1095 NA 0.3 208-10 16.3 1 3 31.8 26.7 95 9.0 13.9 10.6 4.0 44.0 FHP HEV34-1 1,2 LOBBY EACH 1530 200 0.3 208-10 23.0 1 2 46.8 37.5 95 13.0 17.1 10.0 4.0 65.0 FHP HEH52-1 23 NOTES: 1. PROVIDE WITH MANUFACTURERS STANDARD THERMOSTAT 2. PROVIDE WITH CUPRO NICKEL CONDENSERS 3. PROVIDE WITH ACCU-STAT THERMOSTATS 4- CHAMFER 2 TYPICAL AC-13 N.T.S. EXHAUST FAN SCHEDULE DESIG. AREA SERVED LOCATION CFM E.S.P. SONES (AMPS) VOLT/PH. DRIVE MFGR. MODEL No. REMARKS EF-1 PUMP ROOM CEILING 216 .125 2.5 1.3 115-10 DIRECT DAYTON 4C622 1 EF-2 JANITOR CLOSET CEILING 110 .125 4.0 1.1 115-10 DIRECT DAYTON 4C377 2 EF-3 TOILET ROOMS CEILING 216 .125 2.5 1.3 115-10 DIRECT DAYTON 4C622 2 EF-4 Dh1EL_°, RmF SL5 1(5-10 151 LEI U&'(TON 1401 1, CONNECT THROUGH DAYTON 2E369 THERMOSTAT. 2, INTERLOCK WITH LIGHT SWITCH. COOLING TOWER SCHEDULE SYM. WB DB EWT LWT GPM ILP FANS HP POWER DRIVE MFG. MODEL # REMARKS CT-1 80 91 95 85 488 10' 2 3 208V-30 DIRECT P.W.S. 20024 1,2,3 1. PROVIDE WITH 5 YEAR WARRANTY 2. PROVIDE WITH DRIFT ELIMIMATORS 3. 220 NOMINAL TONS HYDRONIC BOILER SCHEDULE SYM INPUT MBTU OUTPUT MBTU TYPE A P GPM Z� T POWER WEIGHT MFG. MODEL N REMARKS B-1 1466 1100 LP 8.8, 110 20- 208/120/24 1240 LAARS PH-1466-1-P-16 1 1. PROVIDE WITH SYSTEM #16 IGNITION SAFEGUARD SYSTEM PUMP SCHEDULE - MARK LINE SIZE GPM TDH IN FT. HP RPM VOLTS 1 PH SERVICE MANUFACTURER IMODEL NUMBER P-1 TACO__ FM-3013 4X3 488 150 t25 1760 208V 3 CONDENSER WATER PUMP P-2 TACO FM-3013 4X3 488 150 25 1760 208V 3 CONDENSER WATER PUMP P-3 TEEL P-61 1-1/4 27.5 15 1 3 --- 115V 1 1 QUNULNSAIL SUMP PUMP NOTES: 1. PROVIDE WITH SUCTION STRAINER 2. TRIM IMPELLER AFTER TEST AND BALANCE 3. PROVIDE P-3 WITH BUILT IN FLOAT SW. AND CONTROLLER. 4 ALT P-i, P-1 MDIAEL- FM 250-1 3SF!' RPM PUMP BASE NO. 5 STEEL RODS + 6" MIN. TO REINFORCE PUMP BASE + 6" MIN. ---TTT NO. 5 STEEL ROD 4-MIN HOUSEKEEPING AIR CONDITIONING GENERAL LEGEND -40% A, " SYMBOL DEFINITION ABBREVIATION - EXISTING DUCTWORK EXIST. DUCT EXISTING DUCTWORK TO BE REMOVED EXIST. DUCT NEW DUCTWORK NEW DUCT EXHAUST DUCTWORK EXH. DUCT OUTSIDE AIR DUCTWORK O.A. DUCT FLEXIBLE DUCT FLEX. DUCT FIRE DAMPER F.D. FIRE AND SMOKE DAMPER F & S.D VOLUME DAMPER V.D. V.D. �^ � OPPOSSED BLADE DAMPER O.B.D. ELECTRIC DUCT HEATER E.D.H. ® CEILING DIFFUSER C.D. SIZE AS RETURN REGISTER OR GRILLE R.R. OR R.G. INDICATED ® ON EXHAUST FAN E.F. DRAWINGS CWS CONDENSER WATER SUPPLY CWS - CWR CONDENSER WATER RETURN CWR - C CONDENSATE DRAIN LINE C --D�- GATE VALVE G.V. CHECK VALVE C.V. UNION STRAINER WITH BLOW DOWN O THERMOSTAT W/ INDICATION OF HEATING OR COOLING SOURCE IT CONTROLS AHU. AIR HANDLING UNIT AHU O.A. OUTSIDE AIR CD-- CONDENSATE PIPE CD B POSITIVE PRESSURE DUCT TURNING UP NEGATIVE PRESSURE DUCT TURNING UP SD SMOKE DETECTOR SD NOTE: THESE ARE STANDARD SYMBOLS AND ALL MAY NOT APPEAR ON PROJECT DRAWINGS. )AMPER f g i9 " grow . 0<. -USER ALL END OF SUPPLY BRANCH 4 END OF SUPPLY BRANCH 3 AC-13 N.T.S. AC-13 N.T.S. c d wt►, z " i In Z O W O L �O O Z z F Ld W UA W w Y c) O F- Q LJ 0 Q U G = c� (n U z LL_1 LI_l U Z Q 0 � Q U LLB Q W � W � � Q Z �- O Q m Z LLJ W ( � O U ry Q C�) U J IIJ LL � m Z // � �J CQC L F = U)i U 0 O I O z u W W 01) Q o t •r t S 2 a S' 1 1 t J A' J/ l�J i 1 1 � , l • W C. h !v C t `e 1� W �c i ail f. ..5 Phi P +N 'q _ # i . 3 At r I � � r T f ,