Loading...
HomeMy WebLinkAboutTRUSS PAPERWORKSOUTHERN TRUSS COMPANIES, INC. SOUTHERN RANDY a@SOU UMRNTRUSS.COM TRUSS 2590 N. KINGS HIGHWAY / FORT PIERCE, FL. 34951 (800) 232-0509 / C772) 464 4160 / (772) 318-0016 Fax: CO M PAN 1 E S Project Name and Address: OAKr AND LAKE Occupancy: X Single -Family Lot:_ �71 _Block: County sTL"' SCANNE® Multi -Family Truss Company: Southern Truss Companies, Inc. Commercial Truss Engineering Program: Mitek Engineering BY Plates By: A itek pla}ei I St. Lucie County Contractor /Builder RYAN HOMES Model: 1452 Elevation: A Options: LANAI STATEMENT, I certify that the engineering for the husses listed on the attached index sheet have been designed and checked for compliance with Florida Building Code FBC2017. The truss system has been designed to provide adequate resitance to wind load and forces as required by the following provision_ ROOF FLOOR Top chord live load: 20 P.S.F. Top chord live load: — P.S.F. Desiga criteria: ASCE 7-10: 160 MPH Top chord dead load: 7 P.S.F. Top chord dead load: — P.S.F. Engineer. Brian M. Bleakly Bottom chord live load: IOs P.S.F. Bottom chord live load. _ P.S.F. Address: 2590 N. Kings Highway Bottom chord dead load: 10 P.S.F. Bottom chord dead load: — P.S.P. Fort Pierce, FL. 34951 Duration factor. 1.25 Duration factor. — Mean height 15' • Exposure: C •10.0 ?.S.F. bottom chord live load aoocuncanmt with anyother live loads. This is an index sheet submitted in accordance with the Department of Professional Engineering. Tallahassee, FL. En iierin sheets are photocopies of the original design and appmved by me. No. Truss ID. No. Truss ID. No. Truss ID. No. Truss ID. No. Truss ID. No. Truss ID. 1 Al 21 J6 41 61 81 96 2 A2 22 J58 42 62 82 97 3 A3 23 15 43 63 83 98 4 A4 24 15A 44 64 84 99 5 A5 25 J4 45 65 85 100 6 A6 26 J3 46 66 86 101 7 A7 27 DA 47 67 87 102 8 A8 28 J2 48 68 88 103 9 A8GL 29 J1 49 69 89 104 10 B1 30 v8 50 70 90 105 11 B2 31 v4 51 71 91 106 12 B3 32 MV6 52 72 92 107 13 B4G 33 Mv4 53 73 93 108 14 Cl 34 MV2 54 74, 94 109 ., 15 C2 35 CJ7 55 75 95 16 C3G 36 07A 56 76 — 17 Ll 37 CJ6 57 77 18 L2G 38 CJ4 58 78 19 J7 39 59 79 20 J7A 40 60 1 80 As witness by my seal, I hearby certify that the above information is true and correct to the best of my knowledge and belief. _ Name: Brian M. Bleakly Lie. 476051 ` � _ .._ ,'/ .. \' � _ - I .1.. 1_ - _ . � < , � i �� ��� �� r- TYPICAL DETAIL G COR.NER. - HIP ~ NOTE NDS=National Design Specifictions for Wood Construction. 132.5# per Nail (D.O.1—Factor=1.00) rids toe nails only _have 0.83 of lateral Resistance Value. .- -,'2 4n tt Ai t:Ai CORNER JACK GIRDER ALLOWABLE REACTION PER JOINT G) UP TO 265# = 2-16d NAILS REO'D. Q UP TO 394# = 3-16d NAILS REO'D. use 2-1Bd too nail TC & BC. Typical jack 45" attachment n TYPICAL CORNER LAYOL1i & Typical Hip —jack' attachment CHORD HANGERS FASTENER GIRDER JACK J1—J3 TO HIP JACK GIRDER TC — — — — — — — 2-16d nails — — — — — BC — — — — — —— 2-16d nails —--—— J5 TO HIP JACK GIRDER TC — — — — — — — 2-15d nails — — — — — BC — — — — — —— 2-16d nails ——-—— J7 TO HIP GIRDER TC — — — — — — — 3-16d nails — — — — — BC — — — — — — — 2-16d nails — — — — HIP JACK GIRDER (CJ7) TO HIP GIRDER TC — — — — — — - 3-16d nails — — — — — BC -— — — — —— 2-16d nails — — — — SOUTHERN MINIMUM GRADE OF LUMBER LOADING (PSF) TM OiaL: oax T.C.20 SYP 12 L 0 FBC7a17 B.C. 2N SYP 2 . 10P 20 WEBS 2:4 SYP No3 BOMM 00 10 SP=NG 24' O.G TRUSS Fort Pierce Division 2590 N. Kings Highway, Fort Pierce, FL 34951 COMPANIES (800)232-0509 1 B-0064-41 so mwl—& Fax:(772)318-0016 Brian M. Bleakly Struct Eng #76051 2590 N. Kngs Highway, Ft Pierce, FL 34951 772-464-4160 + ... .... TYPICAL DETAIL @ CORNER - HIP NOTE: NDS=National Design Specifictions for Wood Construction. 132.5# per Nail (D.O.I—Foctor=1.25) nds toe nails only have 0.83 of lateral Resistance Value. 2 CORNER JACK GIRDER ALLOWABLE REACTION PER JOINT QA UP TO 265f - 2-16d NAILS REO'D. @ UP TO 394J - 3-16d NAILS REQ'D. use 2-16d toe noD a TC & BC. Typical jack 45'—`---"-- attachment TYPICAL CORNER LAYOUT 3-16c nail Typical Hip -jack! attachment CHORD HANGERS FASTENER GIRDER JACK J1—J3 TO HIP JACK GIRDER TC — — — — — — — 2-16d nails — — — — — 8C — — — — — —— 2-16dnails —--— J5 TO HIP JACK GIRDER TC — — — — — — — 2-15d nails — — — — — BC — — — — — —— 2-16dnails — — — —- TC — — — — — —— 3-16dnails ————- BC — — — — — —— 2-16dnails —-——- HIP JACK GIRDER (CJ5) TO HIP GIRDER TC — — — — — — — 3-16d nails — — — — — BC — — — — — —— 2-16dnails — — —— SOUTHERN TRUSS COMPANIES hllie//—FADu emir n IIMUM GRADE OF WN LG 2X4 SYP /2 B.C. - 2.4 51P 2 WEBS 214 SYP No3 LOADING (P6F� 5(R. INCR: L D FBC2017 TOR 20 BOMM 00 ID SPACNlO 2e O.C. Fort Pierce Division 2590 N. Kings Highway, Fort Pierce, FL 34951 (800)2F x:(772)31-0509 8 200164160 Brian M. Bleakly Struet Eng #78051 2590 N. Kings Highway, Ft Pierce, FL 34951 772-464-416D iA 0 S Hangers Face Mount Hanger Charts ReW f'e. iazteW RFJW _ AOomahle lnad5lLbq - - Bnm:.. Uwe 100%71S%125% 16V%' �" -.161as sta0k9m: 1-'Tk e: Eau .16.=.-'...H 0= A" Mae - im W9, Ad.:, JL24 L1124 20 1iJ716 9 7-12 15116 _ 4 10d 2 I 10dxl-12 : 470 .540. 3B0'. 320 - 5, 4 16d 2 10d Y 1-12 • 560 1 640 1 695'. 320 ' 85, F2 JL241FR - 16 1-9716 3-11B 1-12 - _ 4 10d IBfi 2 tOdx1-12 NDG 465 595 580' 28D- 4 160136 2 1 1Ddxl-12NDB 5501 6151 615. 1 230. F32 2x4 JUS24 LUS24 18 1-9116 3-1B 1-W4 1 4 1Dd 2 1Dd vs. 7m 1 835-1 510 14 30124 U24 16 1-9716 3414 2 1-316 _ 4 10d 2 10dxl-12 .:500 .56D 1 6057' 3B0 4 led 2 10dxl-12 We 6651720.I Bee. S. HD26 HU26 14 1316 3-12 2-72 1-18 mu 4 16d 2 10dx1-12 6$' 745 3S5" fi5, Afa 4 .615 :6t5 17451 55 F2 -: J126 - iinc.. 2S� 1.9M 9�-'9/4:-Y-1T1 15d6 _- .6 .:'10d 1 4 .= iDdx.7-]P2:• We 805 870s1 See 1I '6 = t6d 4 1 10dx1-12 ' B40 { 96011045 am ;. JL261FR 1.UC16Z iB-:7-9I76 '4r72.: 'i'!2 _ _ _ " 6 '1Bd101G'..4 930dx1=12 HD61 r55 BW am: 730 31, R1, , 6 16dHDG' 4 110dx1-12HD6 I Bap 954 I IBM 730. - F32 .:111326 '.:-: 411526'-. '. 18 1-8116 4-137161-3M :].< .4 ' 10d -.j .4-1 10d--. 870 100011MD11115 - J 5, R5. F2 �+}g T.4152fi - =MUS26 16-:VMS 54AG •-2 -1'1 -S ;10d 1-6' :'. 10d' 1285 1475 1505 SO: 31. R1, F32 .2s6 N-t- y S1B7�- s 1T26 i - 16., i-816 3-118 T2 - ' ] 3I76 .6- -im { 4-t--10d Y1-172 750 M. 410� '70 6 .:';:18d 'd. -'30><1'-72 ,: 'B80 1DOOi 10B0. r F? .:' - v�isF�.... -�a-' .75i _.< 700S26._ -•'.. 30152ri-- . 16'!. - 1.516 5-7f16 3 `-- - 22 --. I'14 1Sd-: .6 1 16d-! 2760 3140 S 3345 1925 }N2S 1dIT1IF";= :�4., 1-911,6$12 .. 2-12 }4B. ORa'� - 4 `.16d �- lodxi42 .615 695 7d5 365: 5, 615 604745 ' NS 59s- R5, t HD28 H128 -34 1A16 5-17471:172 1�B 88u 8 -'16d 4 1 �. - ledx1-12 '123fl 199011490 780. 9 F2 1230 139011490 an LUX 20 1d16 4-314 142 1516 - 6 led 4 1 11bx1-12 7141 901 SMI 650.1 6 16d 4 I l UD 1 see { 11145.1 650' JL261F-7Z LUC26Z 18 1.9/6 4.12 1-12 - _ 6 10d HDB 4 1 lOdx1-12HDB 60 1 B00 1 870: 730 I 31,R1, 6 16d HDGI 4 11mx1-121{06 •836 950 1035 730 F32 J128 Ur28 20 1-9/16 6Bf8 1-12 15/16 _ 1D led 6 lOdIl-12 :1380 1295 1295: 63 5XF2 10 led 6 1 1OdY7-12 14DO 1500 17401 855 JL79ff-R - 18 1-9116 6-i8 112 - _ B 10d HOfi 4 t0dx1-12 HDG 930 100 1160.1 730: 31. R1, 8 +6d H06 4 10dz1-12 HDG 1105 121511215' 730 F32 JUS26 IJ1526 18 1.9116 4-1316 1-314 1 - 4 lad 4• 10d .870 10W 108o ills MGM LlIS2B 18 1-MG 6-51B 1-W4 1 6 10d 4 10d 111D 127-01 1375.1 1115 S. KF2 a 2x8 MUS26 MU526 18 1-916 5-1116 2 1 - 6 led 1 6 1 led 1285 147511fi05.. 865-- 31. M. AU1S28 hewn 1B i-9116 7-1116 1 2 1 1 B 10d 8 10d 171C 1970 �2140{ 1230 F32 SLUM 1126 16 1.9)16 5-1/8 2 1- 16 _ 6 10d 4 10dxl-12 :750 1840 J 910 1 755: I 6 led 14 1(kdx1-12 BBO 10MI 1080 755 SLDm - 16 1-916 6-58 2 1.m _ 8 10d 6 tOdx 1-12 10DO 112011210 1- see 8 l6tl 6 1Dd 11-12 1175 1395 1440 800: HU626 HUS26 16 1-SB 5-7116 3 2 - 14 16d 6 led 27e0 a140 3345. 1925 5 H1152a taws 16 1-W8 7-3116 3 2 - 22 t6tl 8 16d 41711 4345 43451 2570- s. HD28 HU28 14 i-R16 5.774 2-12 1-18 Men a ifid 4 10d Y7-02 •1230 13ml 14101. 710' ht 6 12D 1390 7490 825 Keno 10210 _ 14 1-916 7.3N6 2-12 1-1/8 me 10 i6d 4 1Ddx1-12 -1540 tIS 1806 78i1 14az 14 6 2153 Z{90 26f0 1170. 1) Up9Rkads have been lmemed 60%ferWDdersdm*kad5wbtlmrinmee dWI bepemlBed. - 2116d drdras (0.148 dia x 3-t14' WM may be osed a1684mthatabk bad Wnem l6d mnunmm era speeftcL Ibis does w1 applyto JUS, HIM, R=staid na0 hoMm 3)For= 1015. end 40Bhmgm Nails uamtbe&hN ata3D'k45a le1loouehft*Wcrt o hd4theheaderleadmethetetde mad1. 4) RAM led x 1-12'tm4s we a148' cFa x 7-72' IDM lm mUsare 0.148' dla x3• Iona 16daals me 0.162' d+a x 3-12' kM Nem pmdude mlgldalsd paxluctbdmma8m madsdwOW m bke foaL Cdrtosien FlOs6 ■Stamlesa Sfeel UGeld CDat T3HDG WfipleZ0lc 112 Cmdhmed on next page 97 F11' Cn (a r. CD • C3 Copyright 0 2018 MITak Industries, Inc. All Rights Resemad U 1501103• RIO ra 11 w 95011m; r. i i IT R V, MM� B 2 NN M INI M — — — — — — — — — — — --- T 7— - I 'Ip.'•'S 23 I amm'SNE — a 3 M M jilm a's il's 3 M Im m 1 M I I — - - -- I I I I I I I I I 1 !7 ;7' 7, +1+ + I? Om 2 ea ee -ee T ee —1 122 1 ez 1 1 In E2 fe I 51 15 us e! ee S 3 Q2 fe ge ig AR! ee � IRE Ee RE! 77 eel ee de P2 ee 2 ee ie se ee 'R 42 12Q N '2I 0 ee INI 'ie w us I v 7 ij W Lq wm 3,e is � id gill HM, 131HP PRRQ^Vrj I SJOBUB11 Copydgh1 V 201B Mrrek Indofihlec. Inc. AB HlBh1s Deserved a • s a qJp? m v .tea V p • � � 1 � � �,. �✓LCj � �' }�qS�1+ � •. � -��'. � �; � � (qy/5 � I � , �.. -: lY lQi�!' � '.. r�13, qN� y� Gj y�+� Gf �Oj iu �' N N,. � •: � m � A � rill I !'•' . ; Y A A A A m Q� yyq TrP Y' 4' ' T 4' 9' 9° 4+ 4' P t` 4 4' T f •4 4 Y' i' � � P �' 9' : Y' 4' � � 4 I a a a 5S Ja •;a a a a a I?l.'✓ N' IV ra N S H.1 4 '3 I I s a..__ i a a a a Er _B.B. .IF N ISrOi#O#�A#T�#O#ONm Nmmmm Ap mp OOlm APmAmO APOt OO:m01 +m�TNA OImm •• n S }sue pJ1 ". .p11 p�1 J m� 1 Q d CODS R p'S p: p� ti p� p� B. q 6 C 6 E� 6 p� 6 p� .ql p1: d C 6 q 6 p IL qJ' q a q .1, d5:, � p� p� p�Wj R R � ' R 6 6 6' 6 6': 6 4 6 6 ¢r bl T b1 � m T P e14 A T T T b. T A TAT P TAN N A A 01 �. T P v N #T m H T. T T T A m A. N m N m p T H T m m H 'Qp�q p p p p: ppp p ppd �R•. N ' '• R R G 6 R ERR R 5 GJ.6 R R Or G G R R •J •� J F4I a a s a 1a112111"IM 91gg��1_1ry110p,24 IN ERR!!PUP-Rigg �g��ENEIE11i-HUg11119 � m'cn g[�'g &' V. _ +y�. +y�• ryo J ti a 8 `el yy I"i: In m• GI a 'd a o. Gi in ya y�? Tri S W tll 6i 2 yvy S "ei yy'. 6 C! lS B Fn' Ili `�. 'I LM Cetf68 nn ' Finish. N L GIDDUBH Ranges Face Mount Hanger Charts M ITe km Jois466e r.v Bract Na 'I ' RetNo. - Steel Goo - brads Qhs.) a ¢ :lAef. Header : - _ Um4.AOmcaWe IN • H' .. 0 �. •A ' Mai . *ft RA OW' . NaH. Fluar 107% Rod. •lls% 12676 up 101 JU546 I LUU6 I 18 3-51B 5 2 1 4 l6d 4 1 16d 1104111 1185 1 I= 113M SI1N46 U46 16 39h6 4-13M6 2 1.In _ 111 111 4 10d 1250114DS 1515j 755 755. 10 16d 4 10d 1470*1167D 1WO4 HIB46 I Hum 14 3-SB 5 2 1 - 4 16d 4 16d /B85 11235 13001.11551 4x6 MJS467 HUSO46 14 8-SM 5 2 1 - 4 16d 4 16d (1085 132351 1300:111551 • H046 KM 14 3-9/16 &tA6 2-12 1-1/8Max SRa 8 16d 4 tOd 1Z30 i 1390 14901 7B0:" 1170 12 6 law] 20185 f 22351 F0)46F HUI:46 14 3-9/16 &1/16 2-12 -Min 8 ifid 4 lOd 1730 13M 114901 780 . { 1170 " Max 12 6 18501 2085 2235 .U&6: '. 1B '3•SB1 =.i5._1 '2 .. 1 - ':.4j 368: 4-." l6tl'; 1104011185 772011355 ' JUS48 '-': 11L448 - 38- -3-SIB I -7/8 2 .. 1'. I. - fi :. 16d - 4..1 16d. iS2511510 1645j 7355 . SUH4fi ; 1 1fi. J-9116 4-73%I6' 2 . 71/B - - .10 .10d -1 4 T. 10H'. 11250 1405 1515' 755 . 10 : 15d 1. a % 10d 1470 1670 1B00Y. 755 " . NIS463":'-:•' HLtW.. 14 ' 3-88 , 5- 2 7• =:1 4 '16d 1 a..' ' 16d :-- 1085. 1235113001 U55. . - HUSa6'th.`: <. F015C46 14'• 3-SB.r:5 4 -16d -' 1={' 16d.- 1085 IM5 13DD.1 1155'I _' IB se.' ; HUS48. 1 14 B-SB 7" - { 2. .'1 6 . 16d.1 6 .16d- 16M 1850 1995{ 18t0 4 x ff' - = �• '_ ' 3 H05C48 ) 14 ' i 3-SB 1 -7 - 2 i- 1... - . - 6 I 16d. 6 , 1 . 16d-. 1625 1 1850 I 1995 1 1810 1 _ . H046 :;.. HU46 74 9-9115 6Af16 2121 1-1/8 BOn.' .g 1 16d 4-1• 1210 1390114901 780 . ism I 065 2235 it70 HD46F. ) HWA6 -- 14 9-9'161 &7716, &721i _ Min. a 7� - - 4 10d 1121a 1 1390/1490/ 780... - 5, R5, 12. 0.. 11850 12035 2235.1 1170 :Iff Jim - 'HU48 . 14 3-911fi &15116.i 2-12 1 [y_7/8 Min 70. In- l6d -4: -'.. 10d:' - 1540 1735 1861.780 F2 Maz 14 '_ fi . 2155 24M 2630 . 1170:. - HD480= .'' -HUC4B S 74 }9/16 &15116; 2-121 1 .. ' 60n '. � 10 . �� . 4 lOd.�-- 115w 1 1735 i 18651 780 Mat- 14 ' 6 2155 24M 26101..1170 JUS48 UIS48 18 3-SB 6-7/8 2 i 6 lad 4 16d 1325 1510 1645 1355 JU5410 WS410 18 &SB 8-7B 2 1 B 16d 6 16d 184512105. 2290 19M SUH410 I U410 I 16 3-9/16 8-38 2 1_118 _ 16 106 6 I 10d 224512420j 11a5 16 16d 6 10d 26'18 20" 1135 HUS48 HUS48 14 3-SB 7 2 1 6 16d 6 16d 11850 105) IBM HUS48th HUSUB 14 3-58 7 2 1 6 tad 6 16d IL% 1995 18111 HD48 HU48 14 3-9/16 &11116 2-12 1-118 Sin 10 16d 4 lOd 173fii 18651 780 Max 14 6 2430 2610 1170 4x10 HD48F RUC48 14 3-06 &15116 2-1/2 _ Min 10 lfid 4 1Dtl j 1735 1JWfi - 7W Max 14 6 2430 2610 . 1170- t5ms H115410 HUS410 14 3-5M B-7/8 2 1 8 16d 8 16d : 2465 2560'. =0" MI OF HUSC410 14 3-58 1 - 8 i6d 8 16d 1 2465. 2660 2210Im410 HU410 14 3-9/16 #1&1,7182 Min14 l6d 6 lOd . 2430 Z610 1170Max 20 10 1'.3415. 3775 1950.'1 04101F HUC410 14 &9/16 F Ift 14 16d 6 10d 7A30 26f0 : U7D .3475 3725 -1950HD0410IF HUC0410 14 3-9116 - 12 W53 6 W53 5590 5598 2975 31, R1, F32 7) Upmt loads have been mmeasad 60%trcwi d orsutsmic bads; an WMerhaease ald be PMMMBd. 2)1fid sinl®s (0.148 dia. x 3-1/4' long) maybe used at 034 ofthetable mad wham 1Bd canmons are spedfied. This does not apply toJUS• HUS, MUS slad ra0 hangers 3) WM Wood Screws are 114' x 3' long and ate Included vAM HD0 hangers 4) KM-10d nails ere 0.148' dia. x 3' long, 16d rails are 0.162' dia x 3-12' Ibng. Newptudn4:is ar updated product Information are desWated In hdrefunt. Carrasion Finish ■StaWess Steel IT601d CD4 EZHDO ETriple Zmc 119 9Z' 1 gr 1, 1 W14fi 'UONy) dsd 0t' Ot, OY01lVlal. ad 00 00 Tl 013 d5d 06 at la ON Jad OZ •Oz ii Ol aNlvhlw ' d IH ivNoU do0 -arm .. •; ,i. •. g4 Io91 unul vlln 1A 1.3O u'WflPyd3 341 al NIa4P up°Lye AV wy3 NOd�3 q ""-e 0(uL4too 1114 NWlnl Pal Pypul 3q al ua nnbl P�Pu 3a�Pu9 3' bm ' 4 ul uW� oB {4-iAP,(ELL), a03a-EIA'E(Ooe) -Ao,°u�3ul -A�m t� �uwm3lPaWSeyum°pp Yi�°D Pu Aect uC)e1n10 ea�eld ltoel e'JOIWvigajOiiaA la ,QppinodLu IR IOU 4 A°Puf ao0au3 L-1 r1 = M '9VO11N3A (IN3 Einis ;IVNON.dO 'a avow ,nO a1� N� abut. ° Lna 2UVA0I099 139 PEt (E) ' A3TWA WONS SY Lna a9Nalld NO 309nbS 3e AYW WHO HOLM • .p SI O330Xd LOH I,EyI300 !NOON IppYmwm 3y:NNLL�LSV ON07 sy ,IV005p3��0 AVY) swdds 830M Gt) SAM IN Jai OOOHO dd013HL i AM VD AONN10'A dQ NflUnd 3NL3 NLYHu •91aN(...I SA7m'AsNo 031I03ds EV OHIOVdS MIOOd LWfI H1 DSSs1311WA NOIMO SVC ,sN33NI0Nl NO ouinds 35Wop SL Ila '00 .,fvIlY yyANN� aIdd sme Arm aL SONd Middy ONa1LY3Ha 1740-O3IIGYUM111dA0Sd ' UNaN. aSOWs 30 ASnW ,3S A971YA HLY3H3S OSnOL d0 Otl01110 daL �py0 �y�y '.0-,ISIWNyC033OXA JAN LVA 1H70ry1�3H0�'ylgYp�y4LW33¢A� A3L11VA WON'Iyh�Yj�W} OEIO �AOVw•'N5l 8yv aawn CAN O 03ddu 3ma'MON91d[Ott7 No A0HI1103d° 0 fi91NO 1 IaZ. w .L FElMS xoW„ 0--,9 0 4>'a ,I Nye. xDw „0—,ti aAu Sd IySy 0N, Ind 'Led n-10 OL ONNV `0111=N '0 'dl9 'ONI0INB meSwin'Naow HVOH " 'ONU,t 'C 01-1. low i00 00L uu 071IYN-3at mini Lire 9.49110) M Pal M m/m�'SSnuL ONONoddna Am aA3L % NDYL HSYLIY (n) yWnbe NO aWWB4 YK Y HOW aeddAh Ya A" CWWGl ,dlloq ,b Co AM #q L4fin ,•Ilia ,a Ep/tl Las N0 NEI ds t•NE WO (4)CYE Na40 11°0 ,•0!9 M E#/Lf AdS EI dAs WE Wa40 daL N39WNl dO 30VN0 WyIWINIW I ta^ m 'Oro J1 1V 01 dSA 00 Pool lolol u I E-j —4 1 HwKn 'IVOUMA vw •uzx N 3on a ra a a tl .E g a„s the ',a et'�irtun�n a W 4 a • a o HIGNTI 3a a otrt , azu in tme do +vnwiHw v ze tsnw owawel -mmaz Fnztttse •ao .a aNV suraz'gqNi� ,at 'ao c tr stm��sa„�s �aa�wae��z�Avi e m xuw aad 3AOBV ,Itry HO. al rrr��aCp�n►a� Pub -0.0 .4Z !V ONIOVdS 3oloaj uolloln0 5L't In i4dLtr 3olooj uollana 9Z't is 1sdo8 3olo0j uo0wn0 CC'L to JodSB 6ulpool unwlxuyl =3 0 yauo al P,uoprea w maq UTM 0=14 •nlmmal mul 341 qoo 92aSjup mul la dM1und{al sN Ias OH�N sWIWJ B La I u —{ =� A/� 09 "m 'O'0 ,0—,i. ® POW HLOS HOV3 NI SllyN Pori H11M OOOM1ld xao ,Z%Lxoxj H A NOV=Old HOVJJ.V* k zzm X/ Vlv--� 0la. O� 1a1 O�i�l 19� i o BV 'I gxg gxg gxg {,xg 0 bxg'L 4x9'L VX9'L 09'L 0 9x9 9x9 9x9 9xb 9 gx£ tix9'Z bx97 -VKZ d .Zg ,9£ b£ 0£ 3dAL 01 do SNVdS 1NIOP '0/O .t !V SllVN PS L UM HOVd1V '11311MH B3M d0 HMN3l 608 ONV H31J39 110 '93SHM -*1 01 .01 93M SV S3103dS '30VH0 3WVS '33VHB „L 4xZ '3/0 •4 1V SINN P9 UM HOVJ.LV '113SW314 oof Al sv .O'adW o3M SplodS '0WMS '3ove ONIOVNB ON A/ 01 ,0 ONIOVW a3alnb3a HION31 03M INVHO ONIOVUS 93M a 3onas mdougo %"*VA )lWR W(WfiW3 11.9N�5pyl�l0 30 8 AVW 5dwLd0 30•Ytld U 3000{ 07. fli 701{ N W pt'0 aHISILV l b 39d Ls= RAW 'al { 'doau NI 3H 99" AM= '0aia msala OL•L 30GY AOH NM aC'GMM HdN—m tsHoWeN00 Am cHmnad 3HL SOd 318V2nddV M W= 691E VNIOWS Nnlllld a3HanlM HOA RN016{i34 aMS a.0319�OrynNta37aL a13311 s n1uY�B�WP9°d3w"�'dloa�NOHO°�d00L l a dLOLao m6Nnund� 7Cd laff Aa mm 61 33nas 3xa LVHL os mmowLa 3a LsnW s3o as aNOHa wwla9 dal " no ,Y LV OWMU {e Hav9mold 2WA s3atld 03HSN Nad N016da Arms aL HUAI j•l1.4 3• dAS *WE •9•M mnra j• z aAs r>2 w•4a u•a i••4 jo Z% d6 vur P'•4a dal u36Wnl d0 30Wo WnWINIW r SCAB -BRACE -DETAIL I ST-SCAB-BRACE Note: Scab -Bracing to be used when continuous la!eral bracing at midpoint (or T-Brace) is Impractical. Scab must cover frill length of web +/- 6. THIS DETAIL IS NOTAPUCABLE WHEN BRACING IS REQUIREDAT-1/3•POINTS OR PBRACE IS'SPECIFtED.- APPLY 2x SCAB TO ONE FACE OF WEB WrrH 2 ROWS OF 10d (3°X 0.131-) NAILS SPACED 6"O.C. SCAB MUST BE THE SAME GRADE, SIZE AND SPECIES (OR BETTER) AS THE WEB. ' ' �\ MAXIMUM WEB AXIAL FORCE = 2500 Ibs MAXIMUM WEB LENGTH =.IZ-W Scar elute 2x4 MINIMUM WEB-S!7F- MINIMUM WEB GRADE OF#3 Nai1s� / SecBon DetaM Scab -Brace Web Scab -Brace must be same species grade (or better) as web member. E L-BRACE DETAIL NaMng Pattern. L-Brace size I Nall Sb% . Nag Spacing 1x4or6 'lod W,o.c. 2x4, 6, or B 16d 8" o.a Note: Nag along entire length of L-Brace. ' (On TwcWVs Nag to Both Pfies).• MI. C9 Web Note. L Bracing fo be used when wn inuous teteral bracing is tmpradical. L-brace must cover BD.90 of web length.- L-Brace must be same spedes grade (or better) as web member.- L-Brace Size for One -Ply Truss Specified Continuous ROWS of Lateral Bracing lAleb S'¢e 1 2 2x3 or2x4 1x4 2rd 128 Zx8 2x8 — DIRECT suBs7nunoN NOT APUCABM L-Brace Ste forTwo-PlyTruss Specified ContinuDnS ' Rows of Lateral Bracing Web Size 1 2 2rGior2x4 2x4 ... 2x6 2x6 2x8 2x6 —DIRECT SUBSnM10N NOTAPUCABIE I T-BRACE / I -BRACE DETML Note: T-Bracing / I -Bracing to be used when continuous lateral bracing is impractical. T-Brace / I -Brace must cover 9N. of web length. Note: This detail NOT to be used to cMwert T-Brace / I -Brace webs to continuous lateral braced webs. Nailing Patteln T-Brace size Nail Size Nag Sparing 1x4orUS 1Dd 8'oa 2x4 or 2x6 or 2x8 16d 8' o.¢ Note: Nag along entire length of•.T--Brace / I -Brace - (On Two-Plys Nag to Both Plies) .: • • - alternate position , t �% `a Jr r t . WEB ,} NWIS / Section DEW T-Brace Web. altemats position Naffs web 1-Brace Nags SPACING T-BRACE _ Brace Size for One -Ply Truss Specified Continuous Rows of Lateral Bracing Web Size • 1 2- 2x3 yr 2x4 1 x4 (7 T-Brace 1x4 (') I -Br 2x6 US (q T-Brace 2x6 I -Brace 2x8 12xB T-Brace 12x8 I -Brace Brace S'v.� for Two-ply Truss Specified Continuous Rows of Lateral Bracing web Size 1 2 2x3 or 2x4 2x4 T-Brace 2x41-Brace 2x6 2x6 T-Brace 2x61-Brace 2x8 2x8 T-Brace 2x8 I -Brace r Brace / 1-Brace must be same species and grade (or better) as web member. (� NOTE If SP webs are used In the truss, 9x4 or US SP braces must be stress rated boards with design values that are equal to (or better) the truss web design values. For SP truss lumber grades up to #2 with 1X bracing material, use IND 45 for T-BMWA-Brat For SP truss lumber grades up to #1 with 1)bracing material, use IND 55 forT-Brace/I Brac FUSS nrss vPe v ymi Homes-lbszna l-A Al COMMON 7 1 Job ReferP.txx 'ne ev,, nvneamausmes, mC PnJ 611.W.U]2Dla Pagel ID:EaPDUhut,WA016wS07JIFdz75dCH1ia1XKPMSNjkdGgpID5GO4FuyA"WLsevBonIz pw 1 7S3 1 11:7-3 21-0-0 INEa 34579 i7 733 62-0 1 7� 13 1 7473 1 6-2-0 83 -1:69.9 i 3xIDM16SHSll 314= 4t6= 3x4= 3x4= 4x6= 3x4= Wo MISSHS 11 1_-0-0 9-2-6 i 1741-13 I 2411-3 1 32-&10 4743-0 -0-0 7 6-26 ]_lira Plate Offsets (X Y7- I1.0-0-14 Edoe1 r1.O-" Edged r9.0-0-14 F_dael f9.Ob4 Edael LOADING(psf) SPACING- 2-0-0 CSL DEFL- in (loc) Udell Lld PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.98 Vert(U) 022 12-13 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 125 SC 0.76 Vert(CT) -OA2 12-13 >999 180 M18SHS 2441190 BOLL 0.0 Rep Stress Ina YES NB 0.59 Hwz(CT) 0.13 9 tlfa We BCDL 10.0 Code FBC2017/rP12014 Matrix-S Weight 213lb Fr= lD% LUMBER - TOP CHORD 2x4 SP No2 •Except• T7: 2x4 SP M 31 DOT CHORD 2x4 SP M 31 WEBS 2x4 SP No.3 WEDGE Left 2x6 SP No2, Right 2x6 SP No-2 REACTIONS. Ob/sbe) 1=1528/D-e-0 (con. D-1-8) Max Horz1=159(I_C 8) Max Uptiftl= 5M(LC 8), 9---529(LC 9) BRACING- TOPCHORD SWctural wood sheathing directly applied. BOT CHORD Rigid Ceiling directly applied a7-58 oe bracing. hb7ek recommends that Sfabliaers and required cross bmang be installed during truss erection, in accordance with Stab'daer Installation pulde. FORCES (m)-Mac CompJhAax.Ten.-All forces 2500b) or less except when shown. TOP CHORD 1-2--4125611114, 2-3=-308311077, 3A=2966I7095, 45=2377/685, 5-0=2377/865, 6-7-296611095, 7-6=3083I1077, 8-9-325811114 BOT CHORD 1-15=10972934, 14-16=-8142449, 13.14=.8142449,12-13=45011809, 11-12--6542449, 10-11=65412449, 9-10=9382934 WEBS 5-M2 3291774, 6-12--650411, 6n9=215r564, e-10=297297, 5-13=-329m4, 413=6501441.4-15=215/564, 2-15=2871297 NOTES- 1) Unbalanced prof five loads have been considered for this design. 2) Wind: ASCE 7-10; VuiF-160mph (3-sec nd gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.OpsF h=Ififk Cat It, Exp C; End., GCp1--0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) A8 plates are MT20 plates unless otherwise indicated 4) This truss has been designed for a 10.0 psf bottom Chad five load nonconamentwith any other five loads. 5) Provide mechanical connection (fry others) of truss to bearing plate capable of withstanding 528 Ib uplift at joint 1 and 529 lb uplift at joint 9. LOAD CASE(S) Standard � f PE 6051 SSj�NAL1NG\\�\\\ ntSs Rrm ype Ryan Homrs•1452Ad 14UA A2 COMUON 2 1 Job Referenma(optionzIl SatNVJr YMS. 34951 Ibv[8.200s Nw302017 Prnt 9200sNw302017 WTax lndusmes, irn Fri 61190:07201a Pape1 ID:EePOLn WCVVAOI&*W7JTFdz?Sd(-gistXKPMSNjkdGgpJD5G04HuyXRXV a Ban' -Pus 7.53 l 11.73 1 1960 127.6�4:a� !L' 7U 1 344 -13 F 42-09 i 7S3 6i-0 6-10.13 743014t0 S1D13 7Fr3 Scale - 1:74D 3X6 = 34 = SDO 12 � _ WO MISSHS II 3x4= 4)15_ 3X4= 3x4= 4x6= 3x4= 3xI0 MIMS 11 9.23 17.613 24-113 324110 41-0-0 42-041 / 8-23 Plate ORsets MY)- f1'0-0-4 Edoe7 It-0-0.14 Edael f o-3-iz&2-8] f6'0-2-8 03A1 r7'0.3-IZO-2A1 rl l:0-0-14 Etl el. fll:GZ4 Edoel LOADING(psl) SPACING- 2)-0 CSL DEFL. In Qoc) Wall Ud PLATES GRIP TOLL 20.0 Plate Grip DOL 125 TO 0.84 Vert(LL) 026 14-16 >999 240 MT20 244/19D TCDL 7.0 Lumber DOL 125 BC 0.76 Vert(CT) -0.5114-15 >968 180 MISSHS 2441190 BCLL 0.0 Rep Stress Ma YES WB 0.52 Ho=(CT) 0.13 11 n/a n/a SC.OL 10.0 Code FBC20177rP12014 MabbcS Weight 211 Ib FT=10% LUMBER. BRACING - TOP CHORD 2x4 SP M 31 `Exwpt+ TOP CHORD Strudloaf wood sheathing directly applied or 3-0-12 oc purrms. T2: 2x4 SP No2 BUT CHORD Rigid calling directly applied or 7.6.12 oc bracing. BOT CHORD 2x4 SP M 31 MiTek recommends that Stabt¢s tr ers and required mosacing be WEBS 2x4 SP No.3 Installed during truss erection, in accordance with StabilUar WEDGE Installation guide. Left 2x6 SP Na2, Right 2x6 SP No.2 REACTIONS. (1b/sae) 1--1529M-8-0 (min. a1-e), 11=152g/0-BO (min.0-1-6) Max Ho21=148(LC 8) ' Max Uptift1=.517(LC 8), 11=517(LC 9) FORCES. (lb) - Max CompJMax. Ten. -All forces 250 (lb) or less exceptwhen shcl TOP CHORD 1-2--3267/1089, 23=3088/1051, 3.4--3012MOSO, 45=2368/826, 7-8=236S/827, 8-9 3012H069, 9.10--308811051, 1(I-11=3267/1090, 64--2133/810, 6-7=21331810 BOTCHORD 1-17=10652945, 16-17=7642428,18-16=764/2428, 14.15=-427/1B28, 13-14=6152428,12-13=-6lW428,11-12=9172945 WEBS 6-14=296T729, 8-14=-590/402, 8-12-2321585, %42--3181313, 6-15=2961729, 4-15- 590/401, 4-17 2MI5B5, 217-�181312 NOTES 1) Unbalanced roof We loads have been considered for this design 2) Wind: ASCE 7-10; Vint= l6amph (3-second gust) Vasd=124mph; TCDL=42psf; BCDL=5.0pst h=15fK Cal. It Exp C; End., GCpr-0.1$ MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to preventwater pondmg. 4) AO plates are MT20 plates unless othervrise indicated. 5) This truss has been designed for a 10.0 psi bottom chord five load nonconctu ent with any other live loads. 6) Provide mechanical connection (ry others) of truss to bearing plate capable of withstanding 517 lb uplift at joint 1 and 517lb uplift at joint it. LOAD CASE(S) Standard i r PE 76051 -O \1 S Al t-01- j -51 ,i/ !R10NI�'�r1G ■ Jet, Ituss lype y Rym�Hnnes-1452Ad I,M-A A3 Fop 2 7 Jab Releresm (oplionall SMM=Tr—, K PknM FL, UZI Rhar8 (116 NoV302017 PdhR 8200a NeV30201]rwTeY Ingusflie; hhc" M 611;00082018 Pagel 3 6♦1 7-00 IDEsPOU1wCWAO16wS07VTFd275tl(-hr8Pk8g4D5taLnmM1 KKp4rd2-0R-07LyMA?NovAlwc-Pu5 1 86I-0522 3 633 Sale=1:70.4 SO = 5Jx1 12 SX5 - 3x5 = 3,4 c 4xS cc W = 3X8 = 41S30 = 36 = /1A 1g,8g su n�o 24BJ1 sa7.1s aaa 4wa t 8M I &1-fa I i-0O i 61-t5 I B64 04-0 Plate Offsets (X.Y)- 11:0-310.0-2A] f6:0S-4 0-2-e1 f120.8.10 0-2A1 LOADING(pst) SPACING- 2)-0 CSL DEFL in (loc) Well Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.93 Vert(LL) -020 16 >999 240 MT20 2441190 TCOL 7.0 Lumber DOL 125 BC 0.42 Vert(CT) -0.41 16-18 >999 180 BCLL 0.0 Rep Stress Ina YES WB 0.77 Horz(CT) 0.13 12 nha rda BCDL 10.0 Code FBC20171TP2014 MatrixS Weight 2271b FT= j(rA LUMBER - TOP CHORD 2x4 SP Noz BOT CHORD 2x4 SP M 31 WEBS 2x4 SP No.3 SLIDER Left 2x6 SP No2 2-11.8, Right2x6 SP No2 2-11-8 REACTIONS. Oh/size) 1=15291041-0 (min. 0-1-8), 12=1529104.0 (min. 0-1-B) Max Harz 1=133(LC 8) Max Uprdn=-500(LC 8), 12-500(LC 9) BRACING - TOP CHORD Structure] wood sheathing directly applied. BOT CHORD Rigid deiTing diledly applied or 7-8-0 no bracing. WEBS 1 Row at midpt 6-15 MlTek recommends flat Stabilizers and required doss bracing be installed during law erection, In acardance with Stabilizer Installation mride. FORCES. pb) - Max CompJMax. Ten. -Ail forces 250 (lb) or less except when shown. TOP CHORD 1-2=-325611053, 2-S=S778H065, 3-"- 0361951, 45=29371960, 5-0=23SWM, 6-7=21241755, 7-8=-23WAM, B-9=2937/960, 9-10-g361951, 10.11=317&1088, 11-12- 3256/1053 BOT CHORD 1-18=1033f2933,17-18=-8052618, 16-17=80512618, 1516-5D42124, 14-15=6722618,13-14=6722618, 12-13=9002933 WEBS 3.18=237256, 5-18=71/428, 5-16=-6431385, 6-16=165/556, 7-15=1171557, 8-15=-6431385, 8.13=721427, 10-13=237256 NOTES- 1) Unbalanced roof five loads have been considered Tar this design. 2) W nd: ASCE 740; Vut=l6Dmph (3-second gust) Vasd=124mph; TCDL=4.2psf BCDL=5,0pst Ir-15Q Cat II; Exp C, End., GCpk0.18; MVJFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This teas has been designed for a 10.0 psf bottom chord live load nonconanrem with any other live loads 6) Provide medhaniral connection (by others) of buss to bearing plate capable of wdhstanding 500lb uplift at joint 1 and 500lb uplift at joint 12 LOAD CASES) Standard 7 PE 6051 �-01 5 AItUt w ����� s/!Ol(I 11 iw runs .s ype Homes-1452Ad 1452-A M HIP 2 1 Job Reference(opflonarl awmall Un19,rE r,eim, rL, 34&ht RUNEe200 Nw 9a 2f11]PnR e2W snw 302a1]E41e1(IMU6GflS,hK FfiF 611:0a:e62016 Pepe1 ID:EaPOLJhVLWA0161uS07JfF&?ScK-IvePkgQDsm n m1w4xdTJL�A,7lavAl., ' 7771.4 1 7-10.12 I 8-0.13 I 2 4&1 30.2 ML-0 &(10 12 5t5 = 3x4= 5t5= Scale=1.70.4 3x5 = 1.5x4 11 31= 3x4 = 34 = 4X6 = 1.&A 11 3x5 = 314 = 20.77i 10I 122 I 1-04 5. 3-0---014 11-0t414 17-02-2 2-9 70. Plate Offsets (X.Y)— I1:0-3-10,0301, r1:0-2.8.0.2-71, (11:0310.03A1 LOADING (PST SPACING- 2-M CSL DEFL. in (loc) Udell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.79 Vert(LL) 024 15 >999 240 Mr20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.83 Vert(CT) -0.4417-18 >999 180 BCLL 0.0 Rep Stress Mc YES WB 026 Horz(CT) 0.19 11 nla n1a BCDL 10.0 Code FBC2017fIP2014 MallkS WeighL 230 @ FT=10% LUMBER - TOP CHORD 2c4 SP No2 *Except' T2: 2x4 SP M 31 BOT CHORD 2x4 SP No2 WEBS 20 SP No.3 SLIDER Left 2x6 SP No2 3.8.4, Right 2x6 SP No.2 3.8-4 REACTIONS. (@!size) 1=152910-M (min. 0-1-13). 11=1529/UW (min. 0.1-13) Max Hum I=118(LC 9) Max Uplitt1=480(LC 8). 11=480(LC 9) BRACING TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid calling directly applied or 6-1-0 no bracing. WEBS 1 Row at midpt 3-17, 6-14, 9-14 Mffek recommends that StabUtzers and required aoss bracing be installed during truss erection, in accordanre with Stabilizer Installation guide. FORCES (Ib) -Max CompJMax Ten. -AU forces 250 (Ib) or less exceptwhen shown. TOP CHORD 1-2- 32751966, 2-3=-014Ma3, 3-0=2591846, 45=2506M9, 5-0=24371904, &7=2279183H, 75=25(151867, 841=25911844, 0-10=314SM84, 10.11=-3275M`1` BOTCHORD 1-1B=9332950, 17-18=a332950, 1&17=-612=1, 15.16=6122291,14.15=68712448, 13-14=835Rg51, 12-13=-835f2951,11-12--8352951 WEBS 348=01314, 3-17=7061420, &17=1001462, 5.15=1071396, 6.14=4351137, 7-14=132I827, 9-14=7071422, 9-12=0/311 NOTES- 1) Unbalanced roof five loads have been considered for this design. 2) Wind: ASCE 7-10-, Vu0=160mph (3semnd gust) Vasd=124mph; TCDL-42psf, BCDL=S.Dpst; h=15t1: Cat It Exp C; Encl., GCpt-0.18; MWFRS (envelope); Lumber DOL=1.50 plate gip DOL=1.60 3) Provide adequate drainage to prevent water pondmg. 4) This truss has been designed for a 10.0 pal bottom chord five load nonconamen l with any other five loads 5) Provide mechanical connection (by others) of truss to bearing plate capable of wffhstamling 480lb uplift at joint 1 and 480 Ill uprft at joint 11. LOAD CAS9S) Standard im ru:5 truss lype Rya,Htmes-f Ad 1452-A AS HIP 2 1 JohReference(opflonan Sa4nm1 russ,Ft Puts, Ft, 34as1 RD:EaPOUhvCWA016 Otd41 7vfFdY15v8PkgQ_PRaLn A"4;d 60n2�`57[N/aAM .ls 7kiLM 7-- Z66A 31-11-2 42Aa 74Y144 fM ]4i0 6 ]4114 5x7 = 15x4 II • Sx1= Scale -1:692 a� 3x5 = 15x4 If 4XB = 3x6 = 3x4 = 1.5x4 II 3x5 = 3x4 = 4x6 = +0 4z-0a tore ]au tss4 zf.aa zasa 3l-ttd 4aao atop , 5o'�d'I�iT—I s5.t F �I �F e3'1 � saf4 o-ta 14w Plate Offsets MY)- 11:0310.0-3-01 N:Ob4.0-2-91 I6:0-54.0-2-e1 19:0310,0301 LOADING(psf) SPACING- 24)-0 CSL DEFL in pm) Well L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.95 Vert(LL)' 029 13 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 125 BC 0.79 Vert(CT) -0.52 13-15 >957 160 BCLL 0.0 Rep Shoes lnrr YES WB 0.56 HOM(CT) 0.19 B rda n1a BCDL 16.0 Code FBC20171iP12014 MataS Weight22316 FT=10% LUM13ER- TOP CHORD 2x4 SP Na2 BOT CHORD 2x4 SP No2 WEBS 20 SP No.3 SLIDER Left 2x6 SP No2 34-13, Right 2x6 SP NO2 34-13 REACTIONS (misae) 1=1529I0-B-0 (min 0.1-13), 9=1529lG4W (min. 0-1-13) Max Ho21=103(LC 9) Max UpbfHl 472(LC 5), 9=472(LC 4) BRACING- TOPCHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-2-10 oc bracing. MiTek remmmenda that StabBd a end required Doss bacing be Installed during three erection, in accordance with Saael izer Installation guide. FORCES. (Its) - Max. Comp./Max. Ten - All forces 250 (9b) or less except when shoxrn. TOP CHORD 1-2---328111030, 23=316411045, 3-4=27241963, 4.5=2855I1104, 5-0=285511104, 6-7=2724M63, 7.8-r-3164/1046, &9=-328111030 BOTCHORD 1-16=6972955, 15-16-8.972955, 14-15=7232461,13.14=7232461, 12-13=71=461, 11-12--7192461, 10-11=8942B55, 9.16-8942955 WEBS 3-16=01269, 3-15=-63/351, 4-15=79/443, 4-13=226844, 5-13=457f348, 6-13=2261644, 6-11=79/443, 7-11=563f352, 7-10=01269 NOTES- 1) Unbalanced roof five loads have been considered forthis design. 2) Wind: ASCE 7-10; Vutt=160mph (3semnd gust) Vasd=124mph; TCDL=42pst BCDL=S.Opst; h=15R Cat 11; Exp C; End, GCpi=0.18; MWFRS (envelope); Lumber DOL--1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This thus has been designed for a 10.0 psf bottom chard live load nammncunerdwith any other five loads. 5) Provide mechanical mnnection (by others) of thus to bearing plate capable of withstanding 472 m uplift at joird 1 and 4721b uplift at joint 9. LOAD CASE(S) Standard ion in, 1russ lype Wen Homes-1452A 1452-A A6 HIP 2 1 •••••^•••-•�'••���••^^+� Hlm: e.4Wa HOx 3V 4a1!M�2 asoos NDV 302n] E ex liven 4 F4 JW 6111WG 2118 Pace ID:EaPOUhVCWA016w507VTFdY75tl(- SoyaRc P7Rtt02wkFZMp9h91G?wMS6Ggiftz_pW 6474 11E-0 t7.70a 24-2-0 3a60 3541-2 424a 60.14 84-0 64-0 fide 5414 E—M 5.ae(12 3x4 = 3x8 — 3x4 = 56 = e a Scale =1:69.3 3x5 = 15x4 11 3xS = 4x6 = 3x4 = 4x6 = W = 15x4 11 3x5 = /LD Lpq �I 64114 W2 2tA0 3af.0 1'N t-2 4— 44 ads a&1 - 2 I 9eq 1 1 •....2 � yy�i4 arm 0AD Plate Offsets (X.YF- 11.0-3-10.04-07 1141-14 EtlgeL 171:0310,03-01 M 7:1-0-3 Edoel LOADING(pst) SPACING- 2-0-0 CSL DEFL in (bc) Well Lld PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.31 15 >999 240 MT20 2441190 TCOL 7.0 Lumber DOL 125 BC OAS Vert(CT) -0.5613-15 >879 1BO SCLL 0.0 Rep Stress Ina YES WS 1.00 Horz(CT) 0.15 11 Na n1a BCDL 10.0 Code FBC2017rIPi2D14 MahtKS Weight 218 Ib FT =10°4 LUMBER - TOP CHORD 2x4 SP No2 BOT CHORD 21c4 SP M 31 WEBS 2x4 SP No.3 SLIDER Lit 2x6 SP Na22-1 M. Right 2x6 SP No22-105 REACTIONS. (011size) 1=152910-8-0 (min. 0.1-8); 11=15291080 (min. 0-1-8) Max Horz1=88(LC 10) Max Upl0t1=497(LC 5), 11=497(LC 4) BRACING - TOP CHORD Structural wood sheathing dhed tly applied or 2.9-3 co purfins. BOT CHORD Rigid ceiling directly applied or74-7 oe bracing. MiTek recommends Ihat StabOizers and required cross bacing be installed during buss erection, in accordance with Stabilizer Installation ouide. FORCES. (lb) -Max CompJMaz. Ten. -AO fonxs 250 (lb) or less exceptwhen shown. TOPCHORD 1-2---3301H099,2-3=324811113,3-4=288811051,45=-263811010,5-8--3280H257, 6-7=-328OI1257, 7.8=2638I1010, 8-9=2886I1051, 9-10�324&1113, 10-11=-330111099 BOTCHORD 1-18=9652874, 17-18=9652974, 16-17=111713216,1516=111713216, 14.15=171513216,13-14=111613216,12-13=98lr2974,11-12=96112974 WEBS 3-17=403292, 4-17=2080782, 5-17=-84M 61, 7-13—B40=1, 6-13=208//82, 9-13=4031292 NOTES- 1) Unbalanced roof five loads have been considered for this design. 2) Wind: ASCE 7-10; Vu1--18Omph (3-second.gust) Vasd=124mph; TCDL=4.2pst BCDL=5.0pst, h=15fk Cat It Exp C; End., GCpr-0.18; MWFRS (emelope); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has bean designed for a 10.0 psf bottom chord live load nonconcunentwith any other We loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 497 to uplift atjoart 1 and 497 Ib uprdt at joint 11. LOAD CASE(S) Standard PE 6051 4 -13-1 �o ORIOalo P�\= Job rWSa In, lype Hw w-145ZAcl 1452 A A7 HP 2 1 Job Referents o 'o awnnvr, iruss,nric�¢, FL,'saspl Po lr a No W=l7Prvrte. sNmW2p17NL7ekaWumiMlnc. Fn JW 611:W.'092n18 Pagel ID:EaPOUhuCWA016wSD7VTFdz7ScK-m5loARd_P7Rad]2iM MpSiNHTvt�_%GgirMzyu4 5dFtd 116-0 17-2-9 2487 W— 36-11-2 42-00 14 45-2 7.9-9 13 -8-9 5414 1-9 SW= t304 II US= 3x4= 5JI012 4 5 fi 7 517 = Stale = 1:59.2 I= MA A011-00,0,1� -a' W Sz7 = 17 16 15 14 19 12 5z7 = 3x5 = W = 4XS = 3xe = 3x4 = 4xS = 3x4 = 3,6 = ta-o asap 1 9Ga t7-gA Z4Sa SZfiO ap3a asap i eaat I ias I pis a.a-o tea Plate Offsets DC.YF- I7:0-M 0.0-3-01, f4:0S4,0-2-81, 18:0-5-4,0-2AI, if 1:0310,03-01, M5:0-2-8.0-1$ LOADMG(pst) SPACM13- 2-M C51. DEFL in Ow) Irdeft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.56 Ved(LL) 0.38 14-15 a999 240 MT20 2441190 TCOL 7.0 Lumber DOL 125 BC OA2 Vert(CT) -0.6414-15 >M 180 BCLL 0.0 Rep Stress Inc YES NB 0.77 Horz(CT) 0.15 11 Na n1a BCDL 10.0 Code FBC2017/TPI2014 Matsu-S Weight 212lb FT =10% LUMBER - TOP CHORD 2x4 SP N" -Except- T2,T3:2c4 SP M 31 BOT CHORD 2x4 SP M 31 WEBS 2x4 SP No.3 SLIDER Left 2x6 SP No2 238. Right 2x6 SP No2 238 REACTIONS. 99sae) 1=1529/9-" (min. 0-"), 11=1529/943-0 (min. 0-1-8) Max H=1=73(LC 9) Max Uphil1=523(LC 5), 11=523(LC 4) BRACIPIG- TOP CHORD Structural wood sheathing diredty applied or 3-0-14 oc pudms. BOT CHORD Rigid ce8mg duhs9y applied or 6.6-11 oc bracing. WEBS 1 Row at mkipt 7.15 Mflek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with StabP¢er Installation guide. FORCES Ob) - Mmr. Comp./Max. Ten. - Ali forces 250 (lb) or less except when shown, TOP CHORD 1-r�27311204, 23=21911211, 3-0=304611137, 4S-3B99/1574, 5-0=3899/1574, &7=-3899/1574. 73-�900/1575, 8-9=3D46/1136, 9-10=321SM211, 1 D-1 1 =-a273M204 BOT CHORD 1-17=105712940,16-17=93712793, 1516=9372793,14-15=1429/3900, 13-14=934/2793,12-13=93412793, 11-12=1054/2940 WEBS 3.17=1761264, 4-17=14/368, 4-15=559M341, 5-15-4341329, 7-14=474/330, 8-14=SBD/1342, B-12=14/368, 9-12=1761264 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-1q VuIF-160mph (3secoad gust) Vasd=124mph; TCDL=4.2psF, BCDL=5.0psf; h=1Sit Cat 1% Exp q End., GCpi4.18; MINFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pondmg. 4) This truss has been designed for a 10.0 psf bottom chord live load nommncu rentwith any other eve loads 6) Provide mechanical connection (by othem) of truss to bearing plate capable of withstanding 523 to uplift at joint 1 and M fir uplift at joint it. LOAD CASE(S) Standard 1 PE 76051 M I *. 71 -o \ s rE-oF OR1 s�j///�Ss�ONA i N Job N55 Imss Iype Ryan Hamel-1452Atl ta52-A I A9 SPECIAL 1 1 Job Reference (oofiwaO �ry ,rc nar¢, ram,JVtial RmI:a S NWW2M7PNKe.2108Nw302017 Mnaft 5me2="M 5119..10201a P29e1 ID:EaPDUKv WAOlBwSO7vTFdz?5cK-FHGA9MSFi7Hb57FUSmou1ipR9UvegBIKwPHN=_pu3 14d i1-a-ol s-0a916�31a a267aWW F SW Scale =1.72-9 5,5 = 7J®i 3x6 = Sr5 = 7XS 11 5.00 t2 515 = 3z4 = Sx5 = 3x4 = Td } 7 89 % 14 12 11MMM 0M. "EM ViA —� 21 20 19 18 17 16 153,5 - 326 = 515 = S 6 = 318 = axe 5's ta.o aao.o 7E-0 1aS1/ 21-0o Zrd2 94f:0 468a 41.0q I sao I sau I saz I s.sz i se-u i sxono a'� o+o vao Plate Oesets MY)- 13:0-2-12,Edgel, I4:0-3-0,EdgeL 15:0-0-3,034). (7:0.2A,Oa-01, 19:0-513,G-%4L [12'0-2-12,Edge). [75:40.11.0.1-101[15:0.2.8,0-24], [17:0-2-0,0-3-4), rls:o-z-D.o-3:atrzg:o-za.o-zrt rzl:ao-11.a1-1m LOADING(pq SPACING- 2-0-0 CSL DEFL. in Qoo) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.82 Vert4) 0,58 18 >819 240 MT20 2441190 TCDL 7.0 Lumber DOL 125 BC 0.99 Vert(CT) 4.9018-19 >522 180 BCU- 0.0 Rep Stress Ina YES WB 0.78 Horz(CT) 0.15 15 We n/a BCDL 10.0 Code FBC2017/rP12014 MaINKS Weight 225 Ib FT = 10% LU6IBER- TOP CHORD 2K4 SP NO2 `&CepP T2,T4:2x4 SP No.3 SOT CHORD 2K4 SP No2 WEBS 2z4 SP No.3 BRACO4G- TOPCHORD BOTCHORD JOINTS REACTIONS. (lb/sae) 21=1554/0-8-0 (min.0-1-13),15--IMAI0-e-0 (min.0-1-13) Maz 1-10172"l (LC 8) MM Uprd21=S26(LC 8), 15=485(LC 4) FORCES. (lb) - MAIL CompJMax. Ten. - All forces 250 (b) or less accept vdm shown. TOP CHORD 1-2- 470f210, 2-3=2779M 103, 35=3806/1587, 5-15=4048M672, 64=455911841, 7-0=4569/1841, S-9=-4024/1656, 9-10=3784/1477,10.12--378411477,12-13=2768I946, 13-14-89/190, 34=2511119, 11-12=2951140, g•11=290M26 SOT CHORD 1-21=235I489, 20-21=316/489,19-2D=101012522, 18-19=1597/4048, 17-18=148114024, 16.17=8172509, 15.16=217/512, 14-16=217/512 WEBS 2-21=1397889, 2-20=-687f2036, 3.19=b76/1700, 6-15--0131364, 6.18=-2191577, 7-18=3771265, B-18=315f7D4, 8-17=-637/393,12-07=741/l755, 13-16=� W001, 13-15=14011643 Struclural wood shea firing directly applied or 2-2-0 oc purrins Rigid ceding direly applied or 2-2.0 oc bracing. 1 Brace atJXs): 10 M17ek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabirmar Inshatlation guide. NOTES- 1) Unbalanced hoof five bads have been considered forlhis design. 2) Wind: ASCE 7.10; Vu"-60mph (3-second gust) Vasd=124mph; TCDL=4.2psF BCDL=5.OpsF, h=I5t1; Cat II; Fxp C; EnCL, GCri=0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) Pmvlde adequate drainage to prevent water pondng. 4) This truss has been designed for a 10.0 psi bottom Chord five load nonboneurrentwith any other five toads. 5) Provide mechanical Connection (by others) of truss to bearing plate capable of withstanding 626 lb uplift atjoim 21 and 485 Ib upfiR at joint is. 6) Graphical pur in representation does not depict the size or the ofierdation of the pudm along the top and/or bottom chard. LOAD CASES) Standard \p�-, [Yt1 IBL�n t PE6051 n �� ,77 IS M IMMW �i O� //Z//;\j�s/O/VA Job FfRyan omu-ta52Atl 144.G AB9L HIP Job Reference o 'on .:EaP0U-- ..-. OIS&G-..Wd-zo..,......-......�.,�..,.w,a...�,..,- ID:EaPOUPuCWA01�607vTF�75tlC-TadnOU72dVsSYkg9aKV WfgiFOde6rATA9ue�7zyuD 14-0 V220 12-11-14 tB&15 gt" W M gp.941 140 F2-0 Sbt4 54d 2 5+2 5514 62-0 140 Scale =ix19.2 5A0 12 5x7 = 1.5x4 II 3a = 41di = tSx4 II 3x4 = 5x7 = 3 22 23 4 24, 25 265 ZT 6 2s 7 29 30 318 32 33 a jIII�¢ 64 // 10 /t 8 y1" 1$ 21 20 34 - 19 18 % 37 3B 77 39 40 41 1fi 42 43 15 14 44 45 4-613 123x5 = 3d= Sx5 - Us M18SHS= 15x4 11 3x6 = 3>6 = Sou = 3xe = 5xs 1NB= +o `t�1 2E-0 iz-tt-1{ 1BS1s S&1 2SOd a0.B9 at0.0� 6+0 � �.yt�� W14 Plate 08sets i%,h- [2.0-2-8,0301, [3.a5-4,0.2-8], [6:0.3a,Ed9eL [9:a-5-4,0-2A1, 110;0.2-8,030], [12'0-0.11,0.1-10], [13:0-2�,0.2-0], [19:03-0,0.1�], [20:0.2�,0-2-0], [27:00.11 .o-t-tot LOADING(pso SPACING- 2-0-0 CSI. DFFL. in Qoc) Udell Lld PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.91 Vert(LL) 0.60 16-17 >787 240 LTM 2441190 TCDL 7.0 Lumber DOL 125 BC 0.51 Vert(CT) -0.83 16-17 >568 180 M18SHS 2441190 BCLL 0.0 Rep Stress Ina NO WB 0.80 Horz(CT) 0.12 12 Na Ma BCDL 10.0 Code FBC20171TP12014 Ma01xS Weight 4321b FT = 10% LUUBER- BRACING - TOP CHORD 2x4 SP No2 TOP CHORD Structural wood sheathing directly applied BOT CHORD 2x4 SP M 31 - BOT CHORD Rigid ceiling directly applied or B-2-0 oc bracing. WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (b/size) 21=2852/03-0 (min. 0-1-8), 12=28621D4;.0 (min. 0.13) Max Horz21=57(LC 8) Max Upld121=1298(LC 5), 12=1298(LC 4) FORCES. (Ib) - Max. CompJMSX Ten. -AD forces 250 (Ib) or less except when shown. TOP CHORD 1-2=7641353, 23=543412601, 3-22=7744/3791, 22-23=774313791, 4-23=7743/3791, 4-24=774313791, 24-25--7743/3791, 25-26=774313791, s26=774313791, 5.27=909714437, 6-27=9097/4437, 6-28=-9097/4437, 7.28=9097/4437, 7-29=9097M437, 29.3D=-9097/4437, 3031=9097/4437, 8-31=9097/4437, Bi2=7764/3797, 32a3=n55r3797, 933=776513797, 9-10=543=800, 10-11=767/359 BOTCHORD 1-21=-36BI766,20.21=428f766,2034=231114943, 3435�2311/4943, 1935=2311/4943, 1936=4335/9118, 1836--43351911B, 1837=-4335MI18, 37.38=433519118, 17-38=4M5/9118,17-09=4335/9118, 3940=433518118, 4D41=4335/9118, 16-41=-0335/9118,16-42-368217754, 42-03--3582rr754, 15-03=388217754, 1544=368277754, 1444=3682R754,1445=23D7/4941, 4546=2307/4941, 1346=230714941, 12-13=3741770, l l-12-3741T7D WEBS 2-21=258911274, 2-20=199014224, 3-19=157813274, 4-19,-M500, 5.19=16157767, 5-17=/430, 7-16=5531491, 8-16=745/1578, 8-14=1368/BB6, 9-14=158713289, 10.13=1987/4219, 10.12=2567H273 NOTES 1) 2-plytruss to be oonnectedtogelherwith 10d (0.131x3' nags ssfollows Top moms connected as follows: W - 1 row at 6-9.6 = Bottom moms connected as follows: 2x4 -1 row at 0-9-0 oc. Webs connected as follows 2x4 -1 row at 0-7-0 or, Except member 20-2 2x4 -1 row at 0-94) m member 213 2x4-1 row at 0-9-0 or, member 19-3 2x4 -1 row at 0.9.0 ca, member 4-19 2z4-1 mw at 0-0-0 m member 19.52x4- 1 row at 0-9-0 M member5.17 2x4 -1 now at 0-9-0 oc, member 16-5 2x4 -1 row at 0-9-0 oo, member7-16 2x4 -1 row at 0-" oc. member 16-8 2x4 -1 row at 0-9-0 or, member B-14 2x4 -1 row at D-e-0ob, member 14-92c4-1 cow at 0-9-0M member 13-92x4-1 now at 0-9-0 oq member 13-102x4-1 rrvat 0-9-0oa �11111/ 2) AD loads are considered equally applied to all plies, except If DOW as from (F) crbadr (S) face in the LOAD CASE(S) section. Ply to ply connections haws been provided to distribute only loads noted as (F) a (0), unless otherwise indicated. \\� 3) Unbalanced roof We loads have been considered for this design. \\ \ -�� r/ 4)WnCLA MWFRSSeE 7-10-, VuLu16OMph (-1w pd gusrip l)Vasd--124m=1.60 ph; TCDL=42psF; BCDL=5.Opst; h=15ft CaL IS Exp C; EncL. GCpr-0.1 \<�t �CENS�,, e, jam DOL 5) Provide adequate drainage to prevent water ponding. 1r PE 6051 (T,�`�7 6) All plates are MT20 plates unless otherwise indicated. �] Mgy%%� eIn designed for a 10.0 psi bottom mom live load nonconcunent with any other We loads. _ Lit — X` itt �\ S %moo`. ORIq NALtE?G Job In, cuss ypa es-1452A 1<52-A AfiGL XW 1 2 Job Reference o 'en Sartaem lrua,KFierm, F1, 30951 Rirt[620aa Nw30201]Rn683aac Nw302a1]w6fek lnau551ea, Ne Fn JN 611:mi:13]m6 va9e2 ID:EaPOt11wC VVA016wS07v7Fdz75cK-fmdnOU72d VsM*aWWROiHMe6rATk0uet7zy W NOTES 6) Provide mechanical connectod (by others) of buss to bearing plate capable of u0standmg 1298 lb upOR at joint 21 and 1296lb uplift at joint 12 9) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s)176 lb dovm and 238 m up at 7-6-0, 94 lb down and 139 m up at 9812, 941 down and 139 lb up at 11812, 94 lb down and 139 lb up at 135-12, 94 lb down and 1391ti up at 1 S.6-12, 94 lb down and 139 lb up at 17.612, 94 lb dovm and 139 lb up at 19-6-IZ 94 01 doom and 139 m up at 214)-0, 94 m down and 139 m up at 22-5-4. 94 lb drnvn and 139 lb up at 2454. 94lb down and 139 m up at 26-5.4, 94 lb down and 139 lb up at 285-4. 94 lb dawn and 139 it) up at 30-5-4, and 94 lb down and 139 lb up at 32-5-4, and 176 lb down and 238 @ up at 34-5-0 on top chord, and 252 lb down and 123lb up at 780, 70 lb down at 9-6-12. 70 lb down at 11812, 70 lb down at 13.6.1z 70 lb down at 15812, 70 lb down at 175-1; 70 lb down at 19812, 70 lb down at 21.0-0. 70 lb doom at 22-5-4, 70lb down at 24-5-4, 70 lb down at 26-5-4, 70 @ down at 29-5d, 70 lb dwm at 30-51, and 70 lb cf v at 32-54, and 252 01 down and 123 0h up at 3454 on bottom chord. The designlselecton of such connection device(s) is the responsmifty of others LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Incease-125, Plate Ino ease=l-25 Uniform Loads (pft) Vert 1.3--54, 3-9=54, 9-11=54,1-11=20 Concentrated Loads (lb) Vert 3=129(13) 8---94(B) 9=129(B) 20=252(B)13=252(B) 22=" 23="(B) 24=94(B) 25=94(B) 25=94(B) 27=94(B) 28=94(B) 29=94(B) 30=94(13) 31=94(B) 32--94(6) 33=94(B) M=47(B) 35=47(B) 36=47(B) 37 -47(B) 36--4`(B) 30-- 47(B) 40= 47(B) 41= 47(B) 4247(B) 43--47(B) 44- (B) 45=47(B) 46=47(B) �-\CENSF�����i t , PE 7Duo' r i '�11t 1k, r y�� .��ll OF ��N S/ONA i 1�?G \\�� im nAS I nm iypa y Harty-1452Ad 1452-A In JUW JVJY COMMON 1 1 Job Refererca (oplianall SwMem Trina. FL PRm. FL.U951 I 414 = 1 1 1 7-11-13 1 13-4-2 I 20-4-0 19 B-11-13 5dS 5-11-14 Smte- 1:33.5 R Plate Offsets MY7- f1:0-0-0.1--21. I1:0-1-14.0-0-21, I6:04A.A.0-51 LOADING(pst) SPACING- 2.0-0 CS1. DEFL in Qcc) trde8 Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.70 Vert(U) -0.12 1-9 >999 240 MT20 244/190 TCDL 7.1) Lumber DOL 125 BC 0.66 Vert(CT) -025 1-9 >96B 180 BCLL 0.0 Rep Stress Inc YES WB 0.17 Horz(CT) 0.04 6 n1a nla BCDL 10.0 Code FBC2017rrP12014 MatrixS Weight 96 lb FT=10 LUBBER - TOP CHORD 2c4 SP NO2 BOT CHORD 2x4 SP NO2 WEBS 2x4 SP No.3 WEDGE Left 2x6 SP Not SLIDER Right 2x6 SP Na2 2-9-10 REACTIONS. (a/size) 6=74010.80 (min. 0-1-8),1=748/0-&0 (min. 0-1.8) Max Horz1=81(LC 9) Max Up00B=252(LC 9),1=258(LC 8) BRACING - TOP CHORD Structural wood sheabimg d'vedly applied or 4 4 oc purims BOT CHORD Rigid ceiling duectly applied or 8.8.5 oe bracing. MTek recommends that Stabilizers and required crass baacng be installed during truss erection, In accordance w8h Stahllm Installation guide. FORCES. Qb) -Max. CompJMax. Ten. -AB forces 250 (0h) or less exreptwhen shaven. TOP CHORD 1-2=13811484, 23--1205/440, X4=11211405, 4-5�-12151442, 5-0=1274/428 BOT CHORD 1-Q-46711224, 8-9=2041837, 7-8=2041837, 6-7=-31911093 WEBS 2-9=2901272, 3-9=182M49, &7=139f32B NOTES- 1) Unbalanced roof five loads have been considered forthis design. 2) Wmd: ASCE 7-10; Vu11=160mph (3-second gust) Vasd=124mph; TCDL=42psf, BCDL=S.Opsf, "5% Cat. II; Exp C; Fstl., GCpk0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord rive load nonconcvrmnt mft arty other five loads 4) Provide mechanical connection (ry others) of truss to bearing plate capable of withstanding 252lb upldtatjoint 6 and 258 lb up5ff atjolyd 1. LOAD CASE(S) Standard ENgF���� i PE 76051 i ' M ' �j c •��ORIOj'�� \\ INI I I lk\G \\\\ 1 /i im n.eS nm lype Ryan Hennes-1452A 1462-A e2 COMMON 1 1 n o:..... n a.oa. .lob Reference rwf • •� �`^• R:EIPOU !/WAOIIwS(37Y Fde?Sc -fmdn M72cDI.I@nPS. nIC Fh Jla 611:0o:1a 2fr16 Pa9C1 ' ID:EaP0U1wCWA076w307vTFdY15cK-istdnOU72dVsSVkg9aKVN7p7M61d<SkOuez 7z�u0 tt4-0 627 1DOe 1 157.7 20.4-0 62.7 3A9 0.8J) 08-0 38] A Smle - UX6 1.0-0 7-01-13 2040 1-0-0 6-11-13 S4S &11-14 Plate Offsets DCYt- I7 0-6-0 1321 H1-14 0-0.21 f3-0.2-0 0.2-111 fb'0-2-0 03U7 IS'42-0 0.2-111 IB'04.4 0-0-57 LOADING(psf) SPACING- 2-0-0 CSL DEFL In Doc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.70 Vert(LL) -0.12 141 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 125 BC M66 Vert(CT) -025 1-11 >950 led I BCLL 0.0 Rep Stress Inc YES WB 0.17 Horc(CT) 0.03 6 Na Na BCDL 10.0 Cale FBC2017/iPM014 MabuS Weight 95 to FT=10°% LUlIBER- TOP CHORD 20 SP No2 SOT CHORD ZA SP NO2 WEBS 2x4 SP No.3 WEDGE Lett 2x6 SP No-2 SLIDER Right 2x6 SP N0.22-9-10 REACTIONS. (Iblsae) 6=740/0-8-0 (min. 0-1-8),1=740/0-8-0 (min, (l.1.8) Max Hwzl=76(LC 9) Max Uplit18=247(LC 9),1=253(LC 8) BRACING - TOP CHORD Structural wend sheathing directly applied or4-2-13 oc pur ms. BOT CHORD Rigid ceiling directly applied or 8-10-12 oc bracing. MiTek recommends that Stabilizers and required cross bmdng be installed during truss erection, In accordance with Stabl6zer Installation guide. FORCES 0b) - Max. CcmpJMax. Ten. -A l forces; 250 (to) or less except when shmum. TOP CHORD 1-2--13731468, 2.3=-12041424, 5-0=1120/391, 6-7=1211/427, 7-0=12661413, 3-0=-1066/416, 45=-995/389 ' BOT CHORD 1-11=-436/1215,10.11=192J839, 9-10=192m39, &9=305/1088 WEBS 2-11=268t258,4-11=1721436,4-9=-131/317 NOTES 1) Unbalanced roof five loatls have been considered forthis design. 2) Wind: ASCE 7-10; Vu1t=160mph (3-s mnd gust) Vasd=124mph; TCDL=42pst; BCDL=5.Dpsf, h=25tk CaL II; Exp C; End., GCpi=0.18; MWFRS (envelope); Lumber DOLh.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load rmnconcunent with any other five loads. 5) Provide mechanical connection Dry others) of toss to bearing plate capable of withstanding 247 to uplift atjoint 8 and 253 lb upfi0 at joint 1. LOAD CASE(S) Standard 01 s 1E aFq NA fj Joe I m65 I ype Henna-1/ Ad 14s2-A as HP 1 1 Job Reference Logormn ^'•'• •'- • •••••�•• •+ _+ rear.., ,,..c rvwalr[Urr YI1rIL 6.2l106rvw 302[r1/a1HeKhMa9na;aK Fa.a4 611. Q132a16 Parat l ttO-a l 1:�EaPOUIwCWA016wSO7vTFdz?5cK.WnOU72dVsS 9aKVVMQ DJVarLMue1L7z_pu0 9.0-0 54-0 1 7-0-0 1 4z4 = W= Scale =1332 ur'r— IM II --' — aka II 1-0-0 a." 134-0 2t-4-0 11•Qa I 7-0-0 I r I JN —� Plate oases My)— f1.9-0 91-3-2 11:0-1-1a ao-2t (2:6-2-4 6-2A1 13.6s-4 o-2-Bt 14'0a-80-4-21 LOADING(psf) SPACING- 2-0-0 CSI. DEFL in Ooc) Odell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.95 Vert(LL) -0.13 1-7 >999 240 MT20 2441190 TCOL 7.0 Lumber DOL 125 BC 0.80 Vert(CT) -0.28 1-7 >852 180 BCLL 0.0 Rep Stress Incr YES NB 0.10 Hcrz(CT) 0.04 4 n/a Na BCDL 10.0 Code FBC2017/TPI2014 MabbS Weight 91 lb FT =10% LUMBER- BRACING - TOP CHORD 2x4 SP No2 `Except- TOP CHORD Structural wood sheathing directly app8ed. T3: 2x6 SP No2 t BOT CHORD Rigid calling directly applied or 10.0-0 oc bracing. ng be VVE CHORD 2x4 SP No.2 WEBS ' MITek recommends that Stabfl a beari and required am 2x4 SP No.3 installed during truss erection, in accordance with Stabeffi WEDGE Installation guide. Left 2x6 SP No2, Right 2x4 SP N0.3 REACTIONS. Ob/size) 4=7401041.0 (min. a1-8),1a40/0-6-9 (mina.1-8) Max Horz1=61(LC 8) Max Up084=228(LC 9).1=235(LC 8) FORCES (lb) - Max CompJMax Ten. - A8 forces 250 (lb) or less except when shaven. TOP CHORD 1-2-12941395, 23=1118/408, 3-4=12281380 BOT CHORD 1-7=290/111z 8.7=27(11081, 5-6=27011061, 45=273/1056 WEBS 2-7=0262 NOTES 1) Unbalanced roof five loads have been considered forthis design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=42ps1; BCDL=SApst h=151k CaL IV F)rp C; Fstl., GCpk0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psi bottom chord live load noncononrent with any other five loads. 5) Provide mechanical connection (by others) of truss to hearing plate capable of vritlstandng 228 fb uplift at joint 4 and 235 It, upfi8 at joint 1. LOAD CASE(S) Standard S 1 a ORI� icb r4R Naa ype Haines-1452Ad 1452.A BOG HIP 1 1 Jab Reference (optional) am, ,rusn, rs raves, rt., s uej ItUrKU0a a NW302017R 8200 aNw30201]NUTek ln4ucbles, Irm Fd J01611:00:1420/8 Pe9e1 IDfaP0Uhv(WA01 S-SO7vTFdz750473Vh71VIpxdj4U0}ATMY4M,..uFYNU1MLz_pu1 680 1680 154a 214-0 6-oa I 4-a-o I a.e-o I e-o.o , 4x7 = 1x4 II ads= 419 = Scale -1:34.6 141-0 8-0O 103-0 754-0 20-4-0 21.4-0 �1.0-0 I 5-0-0 I 48-0 I' 430 � 5-0-0 11-0-0 I Plate Offsets (X Y)— 11d04-10,Edhe1. I3:0.5-4.0.2-M I5:0S4 0-2-01 r7:04-16 Edgel LOADING(psQ SPACING- 2-0-0 CSL OEFL. in (Iox) Ildell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.52 Verku) 0.15 9 >999 240 NrM 244/190 TCDL 7.0 Lumber DOL 125 BC 0.60 Vert(CT) -0.21 9-11 >999 180 SCLL 0.0 Rep Stress Ines NO WB 026 Hmz(CT) 0.07 7 We n/a BCDL 10.0 Code FBC2017RPI2014 MalwS Weight 103 Ib Fr =10 % LUMBER - TOP CHORD 2x4 SP No2 SOT CHORD 2z4 SP No2 WEBS 2x4 SP No.3 SLIDER Left 2d1 SP No22-10-12. Right 2x6 SP Nc22-1 M2 REACTIONS. (Iblsze) 1=1109/0.8-0 (min. o-1-e), 7=110910-0-0 (min. 0-1-8) Max Haz1=-48(LC B) Max Up5ft1=541(LC a), 7=-541(LC 9) BRACING - TOP CHORD Structural mod sheathing directly applied or 3-2-15 oc pudins. SOT CHORD Rigid calling directly applied or 5-10-13 oc bracing. MITek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabili r Installation guide. FORCES. (lb) . Max. CompJMax. Ten. -Ag forces 250 (m) w less except when shown. TOP CHORD 1-2=228411147, 2.3=-221311160, 3-12-260111401,12-13=26OD/1400, 4.13=2604H4D0, 4-14=26001MO. 14-15=2600/14OD, 5-15=2BDtn4G1, &6=-221311160, 8-7=228411147 BOTCHORD 1-11=10042D41, 11-16=10052D55, 10-16=10052055, SAO-10052055, 9.17=10042055,17-18=10042055, 8-18=1004rAW, 7-8=10032041 WEBS 3-11=2a/342, 3.9=347/883, 4-9 =45314D4, 59=347/683, 54-291341 NOTES- 1) Unbalanced roof We loads have been considered for this design. 2) Wind: ASCE 7-10; Vu0=160mph (3se and gust) Vasd=124mph; TCDL=42psf; BCDL=5.Opsf; h--151t; Cal. It Exp C; End., GCpr=0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to preveMwater pond)ng. 4) This truss has been designed for a 10.0 psf bottom chord live toad nonconaurentmdh any other live loads. 5) Provide medranical connection (by others) of truss to bearing plate capable of wilbstending 541 lb uplift at joint I and 541 lb uplift at joint 7. 6) Hanger(s) or other connection device(s) shag be provided sufficient to support concentrated load(s)121 m down and 169 m up at S-M, 57 lb down and 107 m up at 6-0.12, 671b down and 107 to up at 10-G-12, 671b down and 107 lb up at 113d, and 571b doom and 1 W m up at 133.4, and 121 ID doxrr and 169 lb up at 154-0 on top chord, and 106 Ile down and 100 Ib up at 6-0-0. 41 Ile down at 8-0-1Z 41 Ib down at 10.0-12, 41 lb dwm at 1134, and 41 Ib down at 1334, and 1 G6 Ill down and 100 m up at 15-3-4 an bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted ss from (F) or back (8). LOAD CASE(S) Standard 1) Dead+ Roof Live (balanced): Lumber Incase=1.25, Plate Increase=125 Uniform loads OM Concentrated I -ad Qb3 s=5a, s7=6a, to=zo Con Verrt-27 74(B) 5=74(B) 10=—.�=5 27(B)11=106(S) 8=-106(B) 1255(B) 135(B) 145(B) 15=55(B) 16=27(B)17=27(B)18- PE 760517) 17 NA HIM��G \\\\ 13 Job toss liuss type RymhH=m-1452Ad 14 -A C7 COMMON 2 1 Job Reference (optional) BtxMem true, ry vtr FL, 34851 leu[B2(ga NWW 017P 82 a NW3020t7 Mrrelcin4u M hc, Fit JW 611=142018 Pagel ID:EaPOUIWCWA016wS07vTFdz?5cK73Vh?/Ulpudy9JDpe. VWmNanmff- WZxyu7 5-7-14 W2 17-0-0 57-14 3-42 e-0-0 Stale -127.4 414 = 1.0-0 1.4-0 9-0-0 17-0-0 7.6-0 aJ1-0 1 Plate 08sets (X.Y)- f4:644 0-2-01 LOADING(psf) SPACING- 2-M CSL DEF - in (Ico) Odell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.72 Vwt(LL) -0.17 1-0 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.73 Vert(CT) -0.35 1.6 >558 1SO BCLL 0.0 Rep Stress Inc YES WB 0.16 H=(CT) 0.02 5 n1a Na BCDL 10.0 Code FBC2017lrPI2014 Matrix-S Weight 67 W FT =10% LUMBER- BRACING - TOP CHORD 2x4 SP No2 TOP CHORD BOT CHORD 2z4 SP NO2 WEBS 2x4 SP No.3 `Except - BOT CHORD W3: 2x6 SP No2 WEDGE Left 2x6 SP No2 REACTIONS. (Ibls¢e) 5=60610A-D (min. 8-1-8), 1=6081080 (min. 0-1-8) Mm Ham 1=86(LC 8) Max UprM5=2D6(LC 9),1=213(LC 8) FORCES. Qb) - Max. CompJMax Ten. - Air forces 250 (lb) or less except when shown. TOP CHORD 1-2=10541388, 2--�-0141280, 34mZ861254, 4-R=Z=46 BOT CHORD 1-7�3771928, 6-7=-377/928, 5-6 -1711717 WEBS 2-6--303248, 3-0=45/409 Structural wood sheathing directly applied or4-3-12 oc pur ins, except and verlIc215. Rigid calling directly applied or 9-5-14 co bracing. MTek recommends that StabT¢rJs and required cross bracing be Installed during truss erection, in accordance with Ct=blisnr installation guide. NOTES- 1) Unbalanced roar live Wads have been considered forthis design. 2) Wind: ASIDE 7-10; Vu11=160mph (3-second gust) Vasd-124mph; TCDL=32psf. BC.DL=5Apsf h=1511; Cat It Exp C, End., GCpt=0.18; MWFRS (envelope); Lumber DOL=f.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 part bottom chord five load nonconcurrent m th any other five bads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 208 lb uplift atjohd 5 and 213 to upfi8 at joint 1. LOAD CASE(S) Standard BL PE 6051 OR10 SSO/11w1111OG\\\\\\ 1 U Job In= lype Ryanm-l4 Ad i4 A O2 \ CONNON t 1 Job Refererre o ' ••••••v•�•�•a••a ��. JYA, ME.P0Ul WAO16 0'71 ao8Nvx3a xal]rdiTtltlr101BxIE5, IrIG Fd Jw 811:na152018 Paget � ID:EhhPOUNrCWA016wS07vfFtlYlSdC-bF33C3VNaFlehstCH7Mrb6Pi}AFE.IEA1UC7220z�u_ 5577 17-0-0 -14 I i -0I -0i 7-0W. � 8de -126.1 9x4- W11 5 314 = Id 1-0-0 1+P 9-0-0 17-0-0 19 7-6-0 i Plate Oftsefs OLY)- I1;0-0-01321 f1:0.1-14 0-0.21 j3:0-2-0 0-2-111 f5:42-0 0.2-1 it f6:04-0 0.2-01 LOADING(psF) SPACING- 2-0-O CSL DEFL in (bc) BdeB Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.59 Vert(U) -0.17 1.8 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 125 BC 0.72 Vert(CT) -0.36 1-8 >541 180 BCLL 0.0 Rep Stress Ina YES WB 0.15 Horz(CT) 0.02 7 We nla BCDL 10.0 Code FBC2017nPI2014 Matrc.S Weight 67 It, FT =10% LUMBER. BRACING- TOP CHORD 2x4 SP No2 TOP CHORD SOT CHORD 2x4 SP No-2 WEBS 2x4 SP No.3 -Except- + BOT CHORD W3:2x6 SP No2 WEDGE Left 2x6 SP No-2 REACTIONS. (Ib/sae) 7=69810-8-0 (min. a-1-11), 1=69610.8-0 (ndn. 0.1-8) Max Horz1=78(LC 8) Max UpfiR7=197(1-C 9), i=20.5(LC 8) FORCES. (lb) - Max. ComplMax. Ten. - Ali tomes 25D (m) or less except when shown. TOP CHORD 1-2-10411362, 2J=B28264, 5-0=-8891242. 6-7=-526235, 34=7441273, 45=744273 BOT CHORD 1-9=.3461914, 8-9=346Ml4, 7-8=164//44 WEBS 241=281219, 4-0-=281d98 Structural wood sheathing directly applied or 5-0-2 oc purfins, except and verticals. Rigid calling dnectly applied or 9-10-14 oc bracing. MiTek recommends that Stabilizers and required caws bredng� instAW during truss erection, in accordance with Stabilizer Installation guide NOTFS. 1) Unbalanced roof five loads have been considered for this design 2)VAnd: ASCE 7-10; WIt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Dpsf, h= l5q CaL 11; Exp C; Encl., GCprO.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pondmg. 4) This tram has been designed for a 10.0 psf bottom chord live load nonconaurentwith any other fwelcads. 5) Provide mechanical connection (by others) of tNss to bearing plate capable of wdthstandng 197 m uplift at joint 7 and 2051b uplift at joint 1. LOAD CASE(S) Standard E PE 6051 Wit: STjA(3-l�;r<v�� ORIDP%'���� o me9 Nss lypo Rym Hennes-1s62A0 1452-A MG HIP 1 1 Job Reference LoPtiogg Soutlhen Truss, R PWos, FL, 34951 40 = 4x4 = Scale =1:29.1 LOADtNG(pst) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 I SPACING- 2-0-0 Plate Gdp DOL 125 Lumber DOL 125 Rep Stress Inor NO Code FBC2017rtPi2014 I CSL TC 0.78 BC 0.65 WB 0.11 MatrbrS DEFL in Vert(LL) 021 Vert(CT) -0.31 Hoa(CT) 0.02 QW) Udell Ud B-10 >892 240 8-10 >602 180 7 n1a Na I PLATES GRIP MM 2441190 Weight 721b FT =10% LUMBER- BRACING - TOP CHORD 2k4 SP No2 •ExcepC TOP CHORD Structural wood sheathing direc0y applied a 3.7-9 oc pur0m TZ 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 9511 oc bracing. BOT CHORD 20 SP M 31 - Walk recommends that Stabliumes and required cross bredng be WEBS 2x4 SP No.3 Installed during thus erection, In rdance with Stabilizer Insta0agon Puide. REACTIONS. (lb/size) 11=92810-&0 (min. 0443), 7=92810-80 (M!rL 0.1.8) Max Homll=46(LC B) Max Up0g11=462(-C 8), 7=462(LC 9) , FORCES. (lb) - Max CompJMaxTan.-All foroes250(lb) oriels exceptwhen shaven. TOP CHORD 1.2--119Wf606, 23=1356l721, 3-12-1192f683,12-13=1192/683, 4-13=1192/683, 45=13561n(), 5-0=-11B8BD6 BOTCHORD 141=592H184, 1D-11=606/1194, 9.10=604f1192, 9-14-=-604/1192, B-14=.60411192, 7.8=59211184, 6-7=-59Wl154 WEBS 2-11=4=18, 3-10=0285, 4-04)284, 54=-4631318 NOTES- 1) Unbalanced roof five loads have been mnsldemd for this design. 2) Wind: ASCE 7.10; Vu1r160mph (3-semnd gust) Vasd=124mph; TCDL=42ps ; BCDL=S.Opst h=15iK Cat It, Exp C; End., GCp".18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This thus has been designed for a 10.0 psf bottom chord five load nonconcurentwith any other We loads 5) PmMe mechanical connection (ry others) of buss to bearing plate capable of withstanding 4621b uplift atjoint 11 and 462Ib uplift at joint 7. 6) Hanger(s) of other mnner5on devlce(s) shag be provided sufficient to support concentrated load(s)121 ro dmvrt and 169 @ up at S.". 55 Ile devm and 107 Ib up at 6-0-12, and 55 Ile dwm and 107Ib up at 9-114, and 121 Ile tlwm and 1691h up at 12-0-0 on top chord, and 106 Ile down and 10O Ih up at 6-0-0. 41 ib down at e-0.12, and 41 lb down at 9.114, and 1(16lb down and 100lb up at 11-114 on bottom choreL The designtseleegon of such cemedion device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the fare of the thus are noted as front (t) or back (8). LOAD CASE(S) Standard 1) Dead + Roof Live Qrslanoed): Lumber Incxea5c=1.25, Plate Increase=126 Unlionn Loads (Pm Vert 1J 54, 34=54, 4-0-4, 1-6— 0 Coneentmted Loads (lb) Vert: 3=-74(F) 4=74(F) 9=27(F)10=106(F) 8=106(F)12-55(F) 13=55(F)14=27(F) \GENS��L% PE 76051 R GRID \ /ONA 11 \G\\\\ S 6 Job I cuss I tus I ype UwRyan Henna-14 A 1452-A L1 COMMON 2 1 Job Reference o 'on SouMun Truss, R. PWo, FL 3Ca51 Run: 62Ms Nw 302017P 6 aNw 30201714T Irtlustrles. MC rnm a11:Wra 2016 Page, ID£aPOUhVCWAOleWS07vTFdz75CK-UOIa2RZudTFOATBzV*RvmAuRSnhrF3vdPg5FA _ptw S.de -1:189 414 = P 319 II 31911 Plate Offsels_(X.Y)- 11:0-1-14,0-0-21, I1:04)-0,1321, I3:0.1-14.0.421, i3:0Z4.1321 LOADING psi) SPACING- 2-M CSL DEFL in (Ioc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.41 Vert(LL) -0.03 14 >999 240 MT20 244119D TCDL 7.0 Lumber DOL 125 BC 0.49 Vert(CT) -0.06 14 >999 180 BCLL 0.0 Rep Stress Inrr YES NB 0.10 Hom(CT) c.ol 3 n/a Ma BCDL 10.0 Code FBC2017RPI2014 MatrizS. Weight 46 lb FT =10% LUMBER - TOP CHORD 2x4 SP No2 BOT CHORD 2x4 SP NO2 WEBS 2x4 SP No.3 WEDGE Let 2xe SP No2, Right 2x6 SP No2 REACTIONS. (misize) 1=419/0a0 (min.0-1-6),3--419/a6.9 (mNLO-I-6) Max H=1=46(LC 8) Max Uprdl1 145(1-C 8), 3=145(LC 9) FORCES. (lb) -Max. CompJMa Ten. - AO forces 250 (lb) w less except when shaven. TOP CHORD 1-2--656I196, 23- 6561186 BOT CHORD 14=133/547, 34=1331547 WEBS 24--61274 BRACING - TOP CHORD Structural wood sheathing directly applied or 630 oc purlins. BOT CHORD Rigid calling directly applied a 1&" oc bracing. Wrek recommends that Stsblfl a and required cross bracing be installed during truss erection, In accordance vd01 Stabilaeir Installation qulde NOTES- 1) Unbalanced roof five loads have been considered for this design 2) Wind: ASCE 7-10; VuIt=160mph (3•second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=15ft Cat IY Exp C; End., GCpr-0.16; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord rive load nwoonc urrentu th any other rive loads 4) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 145 It uprdt at joint 1 and 146lb uprd atjoim 3. LOAD CASE(S) Standard PE 6051 i O . A- p%3D , dd� i9s//01Ni I m\G\\\\\` I job I `us YPe Y RYOn ones-1452A 14524 l2fi HIP i 1 Job Relererce fouioriarl Scale a 1:192 44 = 4X7 = 3x6 11 . i. 44L0 8.60 1-0O 2R9 I . ,, ,, v M 11-0-0 1 : ff Plate Offsets MY)- 120-0-12.0-1-121 t4:OS4 0-2-0I 15:0.0-12.0-1-121 n:e-0-00-1-121 n:a1-4 1 1-81 t10:0-00 0-1 12t 110:0-1.4 1 1-61 LOADING(psf) SPACING- 2-00 CSL DEFL in Qoc) Vdeff Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 028 Vert(LL) 0.05 B-9 >999 240 Mf20 2441190 TCDL 7.0 Lumber DOL 125 BC 0.37 Vert(CT) -0.08 8-9 >999 1&0 SCLL 0.0 Rep Stress Inc NO 1/dB 0.06 H=(CT) 0.00 7 n/a n1a BCDL 10.0 Code FBC2017/TP12014 Ma06cS Weight 48 m FT=1096 LUMBER - TOP CHORD 2M SP Not BOT CHORD 2x4 SP No2 WEBS 2x4 SP No.3 REACTIONS. (MISize) 19--419I0.8-0 (min. 0 -8), 7=41910-8-0 (min. 0-1-8) Max Horz10=31(LC 8) Max UpfdC10=254(LC 8). 7=254(1-C 9) Max Grav107-421(LC 17), 7=421(LC 18) BRACING - TOP CHORD Structure] rood sheathing directly applied or 60-0 oc pudir s. BOT CHORD Rigid ceiling directly applied or 10-00 oc bracing. MTek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stab filer Installation guide. FORCES. Qb) - Max. Comp -/Ma Ten. - All forces 250 (1b) or less except when shown. TOP CHORD 1-2-315/236, 2J=380/304, 3-11=313R83, 4-11�313283, 45=-780/305, &6=315/237 BOT CHORD 1-10=2261312, 9-10=2311d12, 9-12=222/314, 8-12-222/314, 7$=2271312, 6.7=227/312 NOTES 1) Unbalanced roof five loads have been considered.forthis design. 2) Wind: ASCE 7-10; Vult=l6amph (3-second gush Vasd=124mph; TCDL=4-W. BCD1.=54pst; h=1511; Cat II; Exp C; End., GCpi=O.18; MVJFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This buss has been designed for a 10.0 per boVem chord five load nonroncunerd with any other five loads. 5) Provide mechanical connection (ry others) of truss to hearing plate capable of withstanding 254 m uplift at joint 10 and 254 lb uplift at joint 7. 6) Hanger(s) or other connection device(s) shag be provided suRdentto support concentrated load(&) 53 lb doom and 149 it, up at 4-0-0. and 26 It down and 67 to up at 6-0-12, and 53 lb doom and 149 It, up at B4)-0 on top chord, and 18 m down and 44 m up at 4-0-0, and 8 m down and 2lb up at 6-G-1Z and 18 It, down and 44 to up at 7-114 on bottom chord. The design/selection of such connection device(s) is the responsibgfty of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead * Roof Live 03alanced): Lumber Increasc=125, Plate Increase--125 Uniform loads (pit) Vert 1—=-54, 3-4=-54, 4-6=54,1-6--20 Concentrated Loads (lb) Vert 3--23(3) 4-23(S) 9=2(8) 8=2(I)11=1(B)12=2(13) / PE7�?51� -O 1L 8 TE'OF -" / ORID ///\j�S10NALIEMG rd Jab rows Truss YPe RjF-H es-1452A 1452-A J7 JACK 12 1 .-_...._..__. �. ....�. _ Job RMererce fccrlian . -. -•-••• 1� Fn Jul 611..UtitvMB5YGAID:EaP�l WA0x0wctl-0 w9YT7C0jiFFNM3Nk1T2ApAtLaiePL2zp,a1b1-d-0 I S-2-0 Scale=1:20.3 26 II Plate Offsets OLYI- 1204L12,0-1-121 15:0-1-0 1-2-01 15:04)-0 0-1-121 LOADING(pSO SPACING- 2-0-0 CSI. DEFL in Qce) Udell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.51 Vert(LL) 0.07 4.5 >978 240 NIM0 2441190 TCDL 7.0 Lumber DOL 125 BC 0.39 Vert(CT) -0.f3 45 >569 180 BCLL 0.0 Rep Stress Inc YES WB 0.08 Horz(CT) -0.05 3 We n/a BCDL • 10.0 Code FBC20177fP12014 Maldx-P Weight 24lb FT=10% LUMBER - TOP CHORD ZA SP Not BOT CHORD 2x4 SP No2 WEBS 2x4 SP No.3 REACTIONS. (Ibfsme) 3=14SIMedmimIL 4=97IMedrazr ML 5=335I0.9.0 (min. 0.1-8) Max Ho25=155(LC 8) Max Upfriti=138(LC 8), 5=1o1(LC 8) Max Gmv3=148(LC 1). 4=110(LC 3), 6=335(LC 1) FORCES. (rb) - Max Comp.IMax. Ten. -Ali forces 250 (m) or less except when shaven. WEBS 2-5=295272 BRACING TOP CHORD Structural vrood sheathing directly applied or6-0-0 oc puffins. BOT CHORD Rigid cePng directly applied or 10-0-0 oc bracing. MTek recommends that Stabilizers and required onus bracing be Installed during truss erection, In accordance with Stabif var Installation guide. NOTES- 1) Wind: ASCE 7-10; Vu1t=160mph (3secorld gust) Vasd=124mph; TCDL=42psh BCDL=S.Dpsf; h--15ftCat Ik Exp C; End., GCp'c-0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3 ThisFidlt has b erlsig deor to buss connections. sibottom chord five load nonconammntwith any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of vritllstandmg 136lb uplift at joint 3 and 101 lb upfift at joint 5. LOAD CASE(S) Standard �Q�P-AGE B (� PE 76051 —13—Ia�7w� //�i�ssl /OINA I1 NG \N\ 1 4 job mss nus iypa RyanN=a-1452Ad 14W-A J7A M0N0TRUSS 3 1 Jab Refererce (optional) SeuNerri Treaa.R PiaM FL,3 S51 8-6-D I 66-0 Scale -1:195 Plate offsets MY)- r1:0-1-2.U42421, rl:0.2.6.0-2-121 I4:0-0-0.0-2-121 LOADING(psl) SPACING- 2-M CSL DEFL. in (roc) (dell Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.55 VergLL) 0.10 3-4 >740 240 MT20 244/190 TCDL 7.0 Lumber DOL 125 BC 0.43 Vert(CT) -0.15 3.4 >505 180 BCLL 0.0 Rep Stress Ina YES WB 0.00 Ho2(CT) 0.05 2 n/a Na BCDL 10.0 Code FBC20171TP12014 Mabbc-R Weight 21 lb FT=1(a/e LUMBER- BRACING - TOP CHORD 2x4 SP No2 TOP CHORD BOT CHORD 2x4 SP No2 WEBS 2x6 SP No2 BOT CHORD REACTIONS. (161Size) 2=1541Mechan)eal, 4--23D/D43-0 (mim a."), 3--761Mecrianical Max Hoa4--128(LC 8) Max UprrM-- 136(LC B), 4=-56(LC 8) Max Grav2=154(LC 1). 4=230(LC 1), 3=115(LC 3) FORCES. (m) - Max CompJMmc Ten. -AO farces 25D (lb) or less exoaptwhen shoved Structural wood sheathing directly applied or 6-0-0 oc purfins, except and verticals - Rigid cesmg directly applied or 10.0-0 oc bracing. MTek recommends Nat Stabilizers and required aoss bracing be installed during truss erection, in accordance, with Stabilizer Installation auitle. NOTES- 1) Wind: ASCE 7-1q VuIt=160mph (3-second gust) Vasd=124mph; TCDL=42W. BCDL=5.W, h=1511; Cat 11; Exp C; End., GCpi=0.1 B; MWFRS (errvelope); Lumber DOL=1.6D plate grip DOL=1.60 2) This buss has been designed for a 10.0 psf bottom chord five load noncormrnardwith any other five loads 3) Refer to girder(s) for buss to truss connections 4) Provide mechanical connection (by others) or bum to bearing plate capable of withstanding 136lb uprdtatjoint 2 and 58lb up50 at joint 4. LOAD CASE(S) Standard J 1 PE 6051 I 1 0 1 S 1t of /,//�ss//OjNI�111�G\\\\ aln Job Iuss m- yPe JLUY JP1Y Ryan Hoorn-1�A 1452-A is JACK 10 1 i..w Re. .Y., S011111PJ11r FL,FL, 34951 Rrm. B200a ov302017P 8.200 aH 302017 MTex IneespM s- JW 811:SFI8;rMs Pape, ID:EaPOUMCWA016wS07vTWz75d(-WBg5YGs479YJcry7tigDjll3NP1VMNiAALIeL g.I t•4-0 i 480 Scale -1:175 Plate Offsets (X YI- f2:0-0-12 0-1-121 f5,04-131-2-01 f5'0-0-0 0-1.721 LOADING04 SPACING- 2-0-0 CSL DEFL in OM) Well Lld PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 026 Vert(LL) -0.02 4-5 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 125 SC 020 Vert(CT) .0.04 4-5 >999 180 BCLL 0.0 Rep Stress Inc YES 1NB 0.06 Horz(CT) -0.02 3 We rda BCDL 10.0 Code FBC2017FrP12014 Matrix-P yJeJght JS lb FT=10% LUMBER - TOP CHORD 2x4 SP.N0.2 BOT CHORD 2x4 SP No2 WEBS 2x4 SP No.3 REACTIONS (Ihls¢e) 3=109/Medhanld, 4=47/Medhanlcg 5-2aaM.8-0 (min. 0-18) Max Hbrt5=124(LC 8) Max Upfift3=104(LC 81, 5=-85(LC 8) Max Grav3=109(1-C 1), 4=81(LC 3), 5-283(LC 1) FORCES Qb) -Mac CompJMa Ten. -A0 forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing dhrex:ty applied or 6-04 oc pur8ns BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. MTek recommends that Stabilizers and required cross bracing be Installed during toss erection, in aoordance with Sbrbif¢er Installation gulde. NOTES. 1) Wind ASCE 7-10; Vutt=l6omph (3-second gust) Vasd=124mph; TCDL=42W. BCDL=5.DpsF 1=151t; Cal. I; Exp C; End, GCpr-0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) This ln= has been designed for a 10.0 psf bottom chord five load nonconcumentwith any other five loads. ' 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104lb uplift at joint 3 and 85 lb uplift aljohd 5. LOAD CASE(S) Standard \CEN$��t��/i ( r PE 6051 r i O a OR10 a ms rm ype Rysl Homes-142Ad /4.52d J5a MONO TRUSS 2 1 c, .,T— w ..- n ,.�. Job Reference fopliMo IeRlaauy91p8, mC b"I b11,Y 1e mB raap1 ID:EaPO A016WS07vTFtlY15tlFOgiBpSVGSA7;MJ 7wgDj1JIN0ZWdSTAAUeLz_p¢z 1�-0 44-0 I Scale-1:16A Plate Offsets (X Y)- 12'04-12 0.1-121 f5'0.1411-2-0I f50-0.00.1-121 LOADING(psf) SPACING- 2.0-0 al. DEFL in (too) Udell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 022 Vert(LL) 0.02 4-5 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 125 BC 0.17 Vert(CT) -0.03 4-5 >999 180 BCLL 0.0 Rep Suess; Inc YES WB 0.05 Horz(CT) -0.02 3 We nla SCDL 10.0 Code FBC201711PE2014 Matrixo-P Weight 18 b FT =10% LUMBER - TOP CHORD 2x4 SP No2 SOT CHORD ZA SP No2 WEBS 2x4 SP No.3 REACTIONS. Oblsize) 3=100IMedianiral, 442IMerhaniral. 5-272Po4e-0 (min. 0.1-8) Max HOm5=I17(LC 8) Max UpMCi=97(LC 8). 5=81(LC 8) Max Grav3=10O(LC 1), 4=75(LC 3), 5-272(LC 1) FORCES. (lb) - Max. CompJMax. Ten. -Ali faces 25D (lb) or less except when shaven. BRACING - TOP CHORD StruchrM wood sheathing crm* applied a 54-0 oc pur9ns. BOT CHORD Rigid celting directly applied or 10b0 oc bracing. MO'ek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabil¢er InstaRation oulde. NOTES- 1) Wind: ASCE 7-10; Vult=l8omph (asecond gust) Vasd=124mph; TCDL=42ysf; BCDL=S.Opsf, h=151k Cat II; Exp C; End., G(1pi=0.1 B; MVJFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom tlxud live toad noncenaurerd with any other live loads. 3) Refer to girder(s) for truss to truss connections. , 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 97lb uplift at joint 3 and 61 b uplift at joint 5. LOAD CASE(S) Standard i ` f PE 5051 n _ Scale-1:16J Plate Offsets (X Yh MO.G-120-1-121 I5:0-1-0 1.2 Op r5-6-0-0 0-1.121 LOADING(ps1) SPACING- 2-0-0 Call. DEFL. in Qoc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 020 Varf(LL) -0.01 4-5 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 125 BC 0.15 Vert(CT) -0.02 4-5 >999 180 BCLL 0.0 Rep Stress Inc YES NB 0.05 HOM(CT) -0.01 3 Na We BCDL 10.0 Code FBC2017/IPI2014 Matrbr-P Weight 18 m FT=10% LUMBER - TOP CHORD 2x4 SP No2 BOT CHORD 2x4 SP No2 WEBS 2x4 SP No.3 REACTIONS. Qbadze) 3=96/MechanicA 4=401Mechanirai, 5=267165-0 (min. 0-1-8) Max Ho¢5=113(_C 8) Max Up883=93(LC 8). 5=80(LC 8) Max Grav3=96(LC 1), 4=71(LC 3). 5--267(LC 1) FORCES. (lb) - Max. CompAlax Ten. - All forces 250 Qb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purfinz DOT CHORD Rigid cTmg directly applied or 10.0-Doc bracing. Walk recommends that Stabilaers and required cross breyng ba installed during truss ere rbon, in accordance with Stab0izer Installation culde. NOTES- 1) Wind ASCE 7.10; Vu"- 60mph (3-second gust) Vasd--124mph; TCDL=4.2psF, BCDL=S.Opst,, h=15% Cat II; Exp C; Encl., GCpF0.16; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psi botlom chord live load noneonarrent with any other five loatls. 3) Referto girder(s) for truss to buss connections 4) ProAde mechanical connection (by others) of buss to bearing plate capable of withstanding 93 lb uplift atjomt 3 and 80 Ib uplift atjohd S. LOAD CASE(S) Standard 1 PE 76051 I � \ S� ��O'�`•�c ORIOP%� \ job Russ I russ I ype Ryan Hmnal-1453A 1452-A JSA MONOTRUSS 1 1 Job Reference o 'o Sm rms, FL Pi =. FL.34951 HE �9200c M302017 PmR 6200s Nov 302e17 ANTeJc lrWtuNes.YG F h1611Aa: sMe Pagel ID:EaPOUIwCWAO16wS07vTFdtlStlC-0glegSYGsA7gYJary7wgDj1 JMDJWdKrAAUaz-pbc 4B0 SWe=1:15.6 LOADING(psf) SPACING- 2.0.0 CSL DEFL in (hoc) gde8 Ud PLATES GRIP TCLL 20.0 Plate Grip DOL -125 TC 024 Vert(U) 0.02 3-4 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 125 BC 0.18 Vert(CT) .0.03 3-4 >999 180 BCLL 0.0 Rep Stress lncr YES WB 0.00 Horz(CT) .0.02 2 n1a rda BCDL 10.0 Code FBC2017frPM014 Matm-R Weight 15 to FT=10% LUMBER- BRACING - TOP CHORD 20 SP Nc2 TOP CHORD Structural wood sheathing direr applied or 4-BA oc purlins, except SOT CHORD 2x4 SP No2 end verticals. WEBS 2x6 SP No2 BOT CHORD Rigid ceiling cireetly applied or 10-0-0 ce bracing. ' MiTek recommends that Stab0i7rrs and required cross bracing be installed during Ines erection, In accordance with Stabilim Installation guide. REACTIONS. (1131s¢e) 2=104Rdechanical, 4=16610�M (min. 0-1•e), 3=511Mecharlital Max Horz4=87(LC 8) Max Uplig2=94(LC 8), 4=.36(LC 8) Max Gmv2=104(LC 1), 4=156(LC 1), 3=78(LC 3) FORCES. (Ib)- Max CompJMax Ten. - Ali forces 250 Qb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vu1t=18omph (3second gust) Vasd=124mph; TCOL=4.2psf; BCDL=S.OpsF h=15R CaL It; Exp C; Encl., GCpk0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) This buss has been designed for a 10.0 psi bottom chord live load with any other five loads. 3) Refer to girder(s) for truss to buss connections. 4) Provide mechanical connection (by others) of buss to bearing plate capable of withstanding 94 lb uplift at joint 2 and 36 01 uplift at joint4. LOAD CASE(S) Standard �f PE 76051 NSS I NSs I ype Fianea-USrAtl 1452-A A JQW IMYyai JACK 11 1 Job Reference o 6LW81YOY.WNI/YryR O13A16NAV�M1e LU1/WIeRIM1b91e5. VIG mm ehh:W.ha2 PB981 ID: EaPOUIwCWA0101vS07JfFdz%d(-0q®g5yGs479YJrnyt"D)1LoNRA.WdRAAU =,YM 14-0 4Ad t4-0 I 2sa Seale=1:125 Plate Offsets MY)- 12:0-O-12.0-1-121 f5:0-1-0 1-2-01 f5:0-0-004.127 LOADING(ps1) SPACING- 24)-0 CSL DEFL In (loe) Ildell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.09 Vert(LL) -0.00 4-5 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 125 BC 0.07 Vert(CT) -0.00 4S >999 180 BCLL 0.0 Rep Stress Inc YES WB 0.03 HoM(CT) -0.00 3 his We BCDL 10.0 Code FBC2017rIP12014 Matrbr-P Weight 13 lb FT =10% LUMBER - TOP CHORD 2x4 SP No2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 REACTIONS (Wsire) 3=54/Mechanital, 4=17/Mwhanig6 5--220/0-8-0 (min. a1-9) Max Horz5=&3(LC 8) Max Uptlff3--S9(LC 8), 5=66(LC 8) Max Gmv3=54(LC 1), 4=40(LC 3), 5-220(LC 1) FORCES. (b) - Max. CompJMax. Ten. - Atl forces 250 (t) w less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purfins. BOT CHORD Rigid calling directly applied or 10-0-0 oc bracing. MTek recommends that Stabgtrers and required cols bracing be installed during truss erection, In accordance wit Stabirmer Installation quide. NOTES- 1) Wnd: ASCE 7-10; VurMS(unph (3-second gust) Vasd=124mph; TCDL=42psf, BCDL-5.0psf, h=15R CaL 11; Fxp C; End., GCpi=0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) This tnrss has been designed for a 10.0 psf bottom chord live load nonconwnerdwit arty other We loads. 3) Refer to girder(s) for truss to truss connections 4) Provide mechanical connection (by others) of has to bearing plate capable of withstanding 59 lb uplift atjomt 3 and 66 lb uplift atjohd 5. LOAD CASE(S) Standard Jon I ruSS I runs I ype Homes-1152A, 1452-A J3 ILITY FlyRyan JACK 3 i n Job Reference 0 ' 6o T as. a Piem, FL, 3/951 Run: 8200 s 302017 H 1200 a 362017 A4 ek I In, Fd Jut 611=172016 Page l ID:EaPOU1A CWA016WS07VTF&?Sri(-XdBpCMXeSs?bcAl b000RgWAB_60nA VWft66m-pty 1.40 38d 1-4-0 � 2-2-0 1 Scale =1:115 Plate OBsets DLYl— 12:6-0.12A-1-121, I20-1-11.1-2A1 I5:0.0-0.0.1-121 LOADING(psf) SPACING- 24-0 CSL DEFL in (I=) Udell Lld PLATES GRIP TCLL Mo Plate Grip DOL 125 TC 0.08 Vert(LL) 0.00 5 >999 240 MT20 2441190 TCOL 7.0 Lumber DOL 125 BC 0.06 Vert(CT) 0.00 5 >999 180 BCLL 0.0 Rep Straw Incr YES M 0.03 Horz(CT) -0.00 3 Na n1a BCDL 10.0 Code FBC2017FM12014 Mabi-P Weight 12lb FT=1056 LUMBER - TOP CHORD 2x4 SP No2 BOT CHORD 2x4 SPNo2 WEBS 2x4 SP No.3 REACTIONS. (MISim) 3=381MerlanicaI, 4--81Mechanical, 5=20R -e (min. Max Ho25=72(LC 8) Max Upg83=-48(LC 8), 5=62(LC 8) Max Grev3=38(LC 1), 4=28(LC 3), 6=208(LC 1) FORCES. (1b) - Max. CompJMm Ten. -All forces 250 (lb) or less except when shown. BRACING_ TOP CHORD Structural wood sheathing directly applied or 3.6-0 co purfms. BOT CHORD Rigid calling ?neatly applied or 1041.0 oc bracing. MTek remmmmds that Stabg=m and required cross bii8 g be installed during truss erection, in accordance wilb Stabilizer Installation outdo. NOTES- 1) Wind: ASCE 7.10; Vuit=160mph (3-second gust) Vasd=124mph; TCDL=42psF BCDL=5.0psf; h=15$ Cal. II; Exp C; End, GCpi O.16; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom dxgd We load nonconcurrerdwith any other five loads. 3) Referto girder(s) for truss to truss connections 4) Provide mechanical connection (by others) of truss to bearing plate capable of wlthsanding 48111 uplift atjoint 3 and 62lb uplift atjoint 5. LOAD CASE(S) Standard �\Q3�,'P��ME BCP'�C��ii (; PE 6951 �-jam-Ir ORIDP%'� / N55 rga9 i ype Ryan Names-1452Atl 142-A ,19A MONO TRUSS 1 1 sn:arnma page 7.FaP0UIwCWA016w507v1F jCaeryA1bnOODRgMKsWc8i5wyty 2L0 T Sole = 1:11.6 2L LOADING(pst) SPAC07G- 2-0-0 CSI. DEFL. in Ow) Wall Lid PLATES GRIP TCLL 20:0 Plate Grip IDOL 125 TC O.DS Vert(U) -0.00 34 >999 240 hmo 244,190 TCDL 7.0 Wmbet DDL 125 BC 0.05 Vert(CT) -0.00 34 >999 180 BCLL 0.0 Rep Shess Ina YES WB 0.00 HOM(CT) -0.00 2 nha n1a BCDL 10.0 Code FBC20171rP12014 Natrb(-R Weight 9@ FP=10% LUMBER. BRACING - TOP CHORD 2x4 SP No2 TOP CHORD BOT CHORD 2x4 SP No2 WEBS 2x6 SP NO2 BOT CHORD REACTIONS. (161size) 2-55IAAedhanical, 4=82"4 (min. 0-1-8), 3--T71Mechanial Max HoR4�5(LC B) Max UPIift2--52(Lc B), 4=14(LC 8), 3=3(LC B) Max Grave-55(LC 1), 4=82(LC 1), 3=41(LC 3) FORCES. (lb) . Max. CompJMax Ten. - AB faR 250 (lb) or less except when shaven SWchrral wood sheathing directly applied w2.64 oc purlins, except and verticals Rigid ceding directly applied or 10A-0 oc bracing. Walk recommends that Stabilaers and required cross bracing be installed dudng tmss erection. In accordance with Stabif2er Installation guide. NOTES- 1) Wind: ASCE 7-10; Vut=160mph (3-semnd gust) Vasd=124mph; TCDL=42W,, BCDL=S.Opst h=15fg Cal. it Exp C; End, GCpF-0.16; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) This bum has been designed for a 10.0 pet bottom chord live load r,oncencurrent % th any other five loads 3) Refer to girder(s) for truss to thus connections 4) Provide mechanical connection Dry others) of truss to bearing plate capable of withstanding 52lb uplift at joint 2, 14 to uplift atjolm 4 and 3 uplift atjoirn 3. LOAD CASES) Standard , PE 76051 .t O1N /A 1 M\G \\\\ <1 Z Job ITLISS Iniss lype 1452-A J2 luw Im JApC 12 7 jftmi*anes-I452Aix Job Refeienre o coal ,r , FL rune, ,:wvOr PoOL6 S Ngv96201]RSG ezneNov 30201]Ntrek ltWiaOie; Inc FIJN 611xa172018 Pagel ID:EePOUhYCWAOI6w507JTFdz?5c-Cd6pdDCe557 lb000RgWAL_5ynAgKxV&N=Jily scatee ILLS iEN 2-D-0 Plate Offsets (XY)— 12:0-0-12.0-1-121 IZO.1-11 1.2-81 IS:D-0-0 04-121 LOADING(psf) SPACING- 2-0-0 CSL DEFL. in (1m) Ildetl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.07 Vert(LL) 0.00 5 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 125 BC 0.06 VerUCT) 0.00 5 >999 180 BCLL 0.0 Rep Stress Incr YES 1NB 0.02 Hom(C) -0.00 3 r9a n!a BCDL 10.0 Code FBC2017/17PI2014 Kati Weight 7lb Fr=10% LUMBER - TOP CHORD 2x4 SP No2 BOT CHORD 2x4 SP No2 VJESS 2x4 SP No.3 REACTIONS. (mis7e) 3=341Merhanical, 4=43mtechanlw, 5=22v0-8-0 (min. o-l-B) Max H=5=43(LC 8) Max UprMl3=.34(LC 1), 4=.43(LC 1), 5= 6B(LC 8) Max Grav4=5(LC 8), 5=223(LC 1) FORCES. (lb) -Max. CompJMax. Ten. -AD forces 250(Ib) or less except when shown BRACING TOP CHORD Structural wood sheathing directly applied or2.40 oc purdns. BOT CHORD Rigid ceiling directly applied or 10-" ce bracing. MTek recommends that StabO¢ers and required cross bracing be Instated during boss erection, in accordance with Stabilizer Installation guide. NOTES- 1) Wnd: ASCE 7.10-, Vult=f 60mph (3-second gust) Vasd=124mph; TCDL=4.2pe,, BCDL=S.Opsf; h=1511; Cat II; Exp C; End, GCpi4.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) This tam has been designed for a 10.0 psi bottom chord live load nonconament with any other five loads. 3) Refer to girders) for buss to truss Connection. 4) Provide mechanical connection (by others) of truss to bearing plate capable of vri0lstanding 34lb uplift at joint 3,43 lb uplift at joint 4 and 66 Ili uplift at joint 5. LOAD CASES) Standard - �f PE 76051 �ioM` //`//'9II 10NA11I NG\`\\ 0 e im Nse I nw I ypa limn Homes-1452A 145M J1 JUly JMY JACK 3 1 Job Refererca IoPdonaQ -- _ —__-- 6oiMem Trua, FL Pierce, FL. 34951 Scale =11.4 LOADING(psf) SPACWG- 24)-0 CSL DEF in (loe) Udell Ud PLATES GRIP TCLL 20.0 Plate Gdp DOL 125 TC 0.06 Vert(LL) 0.00 1 wr 120 MT20 244/190 TCDL 7.0 Lumber DOL 125 BC 0.02 Vert(CT) .0.00 1 nh 120 BCLL 0.0 Rep Stress Ina YES INS 0.00 Horz(CT) 0.00 Na Na BCDL 10.0 Code FBC2017/TPI2014 Matrix-P Weight: 5Ill FT =10% LUMBER - TOP CHORD 2x4 SP No2 BOT CHORD 2x4 SP No2 REACTIONS (Iblstre) 2--OS Meduniral, 3=14104-0 (min. 0-141) Max Hoa2--124(LC 1), 3=124(LC 1) Max UpRft2---54(LC 8) MU Grav2--95(LC 1), 3=29(LC 3) FORCES. On) - Max. CompJMax. Ten. - M forces 250 (m) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied a 1-r O oc pudins SOT CHORD Rigid ceiling directly applied or 8-0-0 oc bracing. MTek recommends that StabOfzers and required doss bracing be installed during truss erection, in accordance with StabToer Installation oulde. NOTES- 1) Wind: ASCE 7.10; Vut=160mph (3-seoond gust) Vasd-124mph; TCDL=4.2psF, BCDL=5.0pst, h--15fK Cat It; Exp C; End, GCpF0.1 B; MWFRS (envelope); Lumber DOL=1.60 pale grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconanrerd with any other live loads. 3) Railer to gWer(s) for buss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 541b uplift at joint 2. 5) Non Standard bearing condition. Review required. LOAD CASE(S) Standard �OEN,,' t y PE 051 n - -d 1 5 -I - i ORID /f//�ss/ 1gAI )101�G \\\\ ot% JOb 1russ I Was I Ype QtY RYan RM8.I0. A 1452-A VB jP1Y VALLEY 1 1 �— .R Job ReferWhca o • -- •^^- • cam: E. u ...2ah i hm aao s Rev s02a11 Ydiek lM�6ales, tat: Po JW 611:0020=6 Pape 1 ID:EaPaUIWCWA016wSO7vTFdr.?5dC-yCsYFnZWOnOtodmA3YyeIe6 Gq_XlmdUgplDrvpty 441-0 841d 4-" l 4n W O 1x4 II 4A = LOADING(PSO SPACING- 2-0-0 CSL DEFL in Poe) IIdeff Lid TCLL 20.0 Plate Grip DOL 125 TC 028 Vert(LL) r9a - n1a 999 TCDL 7.0 Lumber DOL I 126 BC 0.18 Vat(CT) Na - n1a 999 BCLL 0.0 Rep Stress Ina YES WB 0.03 Horz(CT) 0.00 3 nla n1a BCDL 10.0 Code FBC2017r P12014 Mabtx-P LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOPCHORD BOTCHORD REACTIONS (Ibrsae) 1=118rBao (min. o-1-s), 3--11a�6-o-B (min. o-1-8), 4--248raao (nilm at-8) Max Horst=25(LC 8) Max UpriM=SB(LC 8), 3=-62(LC 9), 4=52(LC 8) FORCES (0h) - Max CompJMax. Ten. - All forces 250 pb) or less except when shown. Scale = 1:142 20 C PLATES GRIP M-f20 244/190 Weight 24 lb FT =10% Structural wood sheathing directly applied or 6-0-0 co purtine Rigid calling directly applied or 1 o0-0 oc bracing. MiTek recommends that StabBtrers and required am bract be Installed during truss erection, In accordance with Stabilizer Installation guide iM NOTES- 1) Unbalanced roof rive loads have been considered for this design. 2) Wmd: ASCE 7-10; Vuft -160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.0psf; h=15fq CaL 11; Exp C; End., GCpi=0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuos bottom chord bearing. 4) This truss has been designed for a 10.0 psi botom chord five load nonconamentwit h any other five loads 5) Pmvide mechanical connection (by others) of truss to bearing plate=Paola of withstanding 681b uplift atjoint 1, 62 lb uplift atjomt 3 and 52 Ib uplift atjoird 4. LOAD CASES) Standard Lit f PE 6051 5 ��,��1 -J3 - \a OR10 Job I cuss I ype Ryon Nmnes-1�52Atl 1452-A VI VALLEY 1 1 Job Referenm c ' T.. a Pierce. M_ uss1 5.00 F12 3x4 = 2x4 Scale. 1.73 Plate Offsets DCYI- 120-2-0.Edoel LOADING(psf) SPACING- 2-0-0 CSI. DEFL in Ow) Udell Ud PLATES GRIP TCLL xw Plate Grip DOL 125 TC B.04 Vert(LL) We - Na 999 MT20 2441190 TCDL 7.0 Lumber DOL 125 BC 0.13 Vert(CT) nla - n1a 949 BCLL 0.0 Rep Stress Ina YES VM DAD Horz(CT) 0.00 3 nha 'Ia BCDL. 10.0 Code FBC2017frP@014 Matrix-P Weight 10 lb FT=10% LUMMR- TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS (Iblsae) 1=9414 M (min. 0.1.8), 3-944-0-0 (min. 0-1-8) Max Homl=10(LC g) Ma UpoR1=-33(LC 8). 3=33(LC 9) FORCES. (lb) - Max. CompJMax Ten. -All forms 250 Ob) or less except when shown. BRACING - TOP CHORD Structural wood sheathing din:ctly applied w4-0-0 oc purlins. BOT CHORD Rigid calling tiredly appried a 16D-0 oc bmaang. lob Tek recammends brut 595lrr2 and required doss bracing be installed during truss erection, In accordance with Stablloner Installation gulcle. NOTES 1) Unbalanced roof We loads have been considered for this design. 2) Wind: ASCE 7-10; Vu1t-16omph (IGerand guq Vasd=124mph; TCDL=42psf; BCDL=5.Opsf, h=15fk CaL 11; Exp C; End., GCpi=0.18; MINFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.6D 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord five load nonccncunentwith any other We loads. 5) Provide mechanical connection (ry others) of buss to bearing plate capable of withstanding 33 lb uplift aljomt 1 and 33 lb uplift atjoim 3. LOAD CASE(S) Standard \� i EN PE ( / PE �1 ���ORIDj' nxss Iruss lype Ryxn runs-1452Atl 1452` -A M VALLEY ILRY IM] 2 1 Job Referenrx: r� maw onucia <vin mDor IOFaPOLWwCWA016wSO7vTFdY15cK-UOIa2RZud7F0ATBzWiRvrtroaMYngIF4XtlPg5FA�¢,piw Scale-1:14.8 2 3 Zx4 % 15x4 II LOADING(psO SPACING- 2-M CSI. DEFL in Ooc) Vde6 Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.73 Veit(U) Na - Na 999 MT20 244M90 TCDL 7.0 Lumber DOL 12.5 BC 0.5B Veri(CT) Na - nla 999 BCLL 0.0 Rep Stress Iry YES WB 0.00 Hom(CT) 0.00 Na his BCDL 10.0 Code FBC2017lrP12014 MatruaP Weight 20 m FT=10% LUAIBER- TOP CHORD 2x4 SP No.3 HOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 REACTIONS. Oblsize) 1=19018-0-0 (min. 0-1.8), 3=19016.0-0 (min. 0-1-8) Max Horz1=105(LC 8) Max UprdH=.57(LC 8). 3=101(LC 8) FORCES. (lb) - Max. CompJMax. Ten. - AO forces 250 (lb) or less a ptwhm shown. BRACWG TOP CHORD Structural wood sheathing directly applied or 6-" oe purhns, except end verticals. BOT CHORD Rigid caging &racily applied or 10-0-0 oc bracing. U'Tek reoommwds ttud Stabfl a and required cross bmdng be Installed during truss erection, in accordance with Stabil¢er Installation Wide. NOTES- 1) Wind: ASCE 7-10; VuR--160mph (3-secand gusQ Vasd=124mph; TCDL=4.2psF BCDL=5.Opst; h=15% Cat It Exp C; End., GCpr-0.1e, MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) Gable squires continuous botom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord We load noncancu entwith any other rive loads. 4) Provide mechanical connection (ry others) of truss to bearing plate capable of wilhstandng 67 lb uplift atjoim 1 and 101 lb uplift at joint 3. LOAD CASE(S) Standard PE 76051 H47 �0'�`•�c ORI�P%'= � l//j\SS�%NAL1�1�G`\\\\\ 2� Job NSA Iruss lype Home- A 1452-A MVd VALLEY 2 1 Job Reference (optianall SOWfem Truss, FL Plm FL, 34e61 2x4 O R 62005 Nm•e02011Pm¢62006Nov802017WTeklndusMss,con Fnd 51194192018 Paga1 ID:EaPOUIwCWA016wSO7vTFdz?ScK-UOla2R7, dTF6ATBzVAft aUOnmSF4XdPg5Fkm_pdw 1.5X4 II Scale-1:109 LOADING(psl) SPACING- 24)-0 CSL DEFL In pog) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 025 Vert(U) We - Na 989 MT20 2441190 TCDL 7.0 LumberDOL 125 BC 0.19 Vert(CT) Na - Na 999 BCLL 0.0 Rep Stress Incr YES 1AB 0.00 Horz(CI) 0.00 Na Na BCDL 10.0 Code FBC2017ITP12014 Matrix-P Werght 13lb FT=10% LUMBER- BRACING - TOP CHORD 2x4 SP NM3 TOP CHORD BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BOT CHORD REACTIONS. (lolslze) 1=116144)-D (min. 0.1A, 3--11614-0-0 (min.0-1-8) Max Horz1=S4(LC B) Max UpliM=35(LC 8), 3=-62(LC 8) FORCES. (lb) - Max CompJMax Ten. -AO forces 250(lb) or less except when shown Structural wood sheathing directly applied or 4-0-0 oc pudlns, except end verticals. Rigid calling directly applied or 10-0.0 oc bracing. Mrrek recommends that Stabilizers and required cross bracing be Installed during truss erection, in accordance with Stabilizer Installaffon guide. NOTFS- 1) WinE: ASCE 7-10; VuR160mph (.second gust) Vasd=124mph; TCDL=4.2psf BCDL=5.0pst; h=151t; Cat It Fxp C; EmL. GCpk0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This buss has been designed for a 10.0 psi bottom chord live load noncommrrentvd0h arry other We loads 4) Provide medhanicel connection (by others) of truss to bearing plate capable of withstanding 35 lb uplift atjoird 1 and 62 m uplift atjoird 3. LOAD CASE(S) Standard / PE 76051 �s1ONALII�G.\\\\\ `� h Jac I rus lrus lype Ryan Hunea-1452Ad 1452-A M2 VALLEY 2 1 Job Reference (DPUW SaMem—^F.06, FL. 34951 W9 Riara.2age w302017 Pn11C 82g8s 3tl 20175kTek tntluemez bhc nJg 611:Od192o18 Pagel ID:EePOUIwCWAO16wSO7vTFdz?ScK-UOla7RZuo TFOATBzVVrRvmw9XMnoTF4XdPg5FAt=_pica c nnr Scale =1ba LOADING(psfd SPACING- 2-M CSI. DEFL- in Qoe) Udeti Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.04 Vad(LL) n1a - We 999 Mr20 2441190 TCDL 7.0 Lumber DOL 125 SC 0.03 Vert(CT) n1a - Na 999 BCLL 0.0 Rep Stress Ina YES WS 0.00 Hom(M) -0.00 2 We We BCDL 10.0 Code FBC2017lrPI2014 Mabbr-P Weight 5 lb FT =10% LUMBER - TOP CHORD 20 SP No.3 BOT CHORD 2x4 SP No.3 BRACING - TOP CHORD BOTCHORD REACTIONS. (lb/size) 1= 47rz-0-6 (nda 0.1-8), 2--34M-M (min. M41). 3=1312-0.0 (m n. 0-1-6) Max Hoa1=26(LC B) Max UprdH=14(LC 8), 2-31(LC 8) Max Gmv1=47(LC 1), 2=34(LC 1), 3--25(LC 3) FORCFB. (lb) -Max. CompJMm Ten. -AO forces 250(Ib) or less except when shown. Structural wood sheathing directly applied or2-0-0 oc purilm Rigid ceiling directly applied or 10-0-0 oc bradng. MTek recommends that Stabifibm and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide NOTES 1) Wmd: ASCE7-10; VuIt=160mph (3-second gust) Vasd-124mph; TCDL=42W,, BCDL=5.Opsf; h=1511; CaL It Exp C; End., GCpl--0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord Eve load nonconcurrentwith any other rive bads. 4) Bearing atjodm(s) 2 considers parallel to grain value using ANSUiPI 1 angle to grain formula. Building designer should verify rapacity of bearing surlam 5) Provide mechanical connection (by others) of truss to bearing plate capable of wmrstanding 14lb uplift atjdrd 1 and 31 lb uplift of joint 2 LOAD CASE(S) Standard PE 6051 S�OR, NA I i .1-a16 1 64-7 - 1D.&12 1-&14 4ba 1 4-1-5 ' f-a141 6A-7 1 tOS12 104L72 144 DS11 4b9 d_1S 1 Plate Offsets (LY)- f2:0-0-9,0.1-121, 12:0.1-7,1-7-141, f8:0-0-0.0.1-121 LOADING(psf) SPACING- 2-M CSL DEFL In Poo) Udell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.45 Vert(U) .0.04 6.7 >899 240 MT20 244/190 TCDL 7.0 Lumber DOL 125 Sr 0.43 Vert(CT) -0.08 64 >999 180 BCLL 0.0 Rep Stress; Ina NO WB 0.16 Hom(CT) -0.03 4 Na Ma BCDL 10.0 Code FBC20171fP12014 Mobt(S %Wght 41 lb FT=10% LUMBER - TOP CHORD 2x4 SP No2 GOT CHORD 2x4 SP No2 WEBS 2x4 SP No.3 BRACING- TOPCHORD BOTCHORD REACTIONS. (161sae) 4--1111Mechaniral, 5=2341Medraniral, 8=46110-11-5 (rrum 04-8) Max Hom8=153(LC 4) Max UpM4=94(LC 4), 5=1D4(LC 4). 8=186(LC 4) FORCES. (1b) - Max. Comp.IMax. Ten. -All forces 250 (b) or less except when shown. TOP CHORD 1-2=3811115, 2-9--4431159, 3.9=394N69 BOT CHORD 1-8=1081383, 8-11=249383, 7-11=2491383, 7-12=249/d83, 6-12=24arSM WEBS 2-0=3031190,3-6---03V281 Shuctural wood sheathing directly applied or 61F0 oc pur6ns. Rigid peiTing directly applied or 10-0-0 oc bracing. MTek nuarmmends that Stabilizers and required cross bracing be installed during truss erection, In accordance with Stabilizer Installal on guide. NOTES 1) Wind: ASCE 7-10; Vut=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; ECDL=5.Dpst h=15f1; Cat 11; Exp C; End., GCp1=0.18; MWFRS (envelope); Lumber DOL=1.60 plate gdp DOL=1.60 2) This buss has been designed for a 10.0 pal bosom chord five load nonconcurrentwith any other We loads. 3) Referto girder(s) for truss to buss connections. 4) Provide mechanics) connection Pry others) of truss to bearing plate capable of withstanding 94 lb uplift atJoim 4,104 lb uplift aljoim 5 and 186 lb uplift atjdnt 8. 6) Hanger(s). or other connection device(s) shag be provided sufficient to support concentrated load(s) 23 lb down and 38 m up at 5.0-7, 23 lb doom and 38 lb up at 541-7, and'51 lb down and 93 lb up at 7-10-6. and 51 lb dam and 93lb up at 7.1" on top chord. and 4 @ up at 5-0-7. 4 m up at 5b7, and 21 lb down at 7-10-6, and 21 lb down at 7-10-6 on botom short The desigrYsetection of such connection devira(s) is the responsibility of others_ 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or bark (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balances: Lumber Increase=125, Plate Increase=125 Unifonn Loads (pill Vert 1-4- 54,1-5=20 Concentrated Loads Ph) Vert 10--39(F=l9. B=19)11=7(F=4, 8=4)12-24(F=12, B=12) = t i PE 76051 �tt SYTFor ORI� N NA 11EN\\\�\ -2S job rh6.T truss lypq Homes-1452A 1452-A CJ7A MONO TRUSS 1 t Job Refererire o ona SOWiem Truss, Ft PvrE, FL, 34951 Scale -1:199 LOADING(psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 125 Lumber DOL 125 Rep Strew Inv NO Code FBC2017/TPMM4 CSI. TC 0.27 BC 0.38 WB 0.22 MaftS DEFL in Vert(LL) 0.03 Vert(CT) -0.05 Hor4(CT) 0.01 Q=) gtleg Lid 6-7 >999 240 6-7 >999 180 5 Na n1a PLATES GRIP MT20 2441190 Weight 40 lb FT=10-A LUMBER- BRACING. TOP CHORD 2x4 SP No2 TOP CHORD Structural wood sheathing dire l applied or 6-0-0 oe pur6ns. SOT CHORD 2x4 SP NO2 SOT CHORD Rigid ce3ng directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 9N7ek recommends that cmbnaar= and required cross be SLIDER Le1t2x4 SP No.3 2.6-10' Boner InsWletl during truss erection, in accemance with Shahif¢e Installation guide, REACTIONS. Qbls¢e) 1=358104" (min.0-IS),4=1o5/Mechaninl,5=28SNechanicel Max Ho¢ 1=163(LC 17) Max UpIlft1=144(LC 4), 4=91(LC 4), 5=139(LC 4) FORCES. (Ib) - Max. CompWax. Ten. -All forces 250 (1b) or less exceptwhen shoe TOP CHORD 1-2-605233, 2-8=5 39, Nr—W 1245 BOT CHORD 1-10=324/531, 7-10=.324/531, 7-11=.324/531, 6-11=324/531 WEBS 3-7=0261, 3E-5981365 NOTES- 1) Wind: ASCE 7-10; Vint-16Dmph (3-second gust) Vasd=124mph; TCDL=42pst BCDL=5.Opst; h=15% Cat II; Exp C; Encl., GCpF0.16; MWFRS (emrelope); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psi bottom chord live load nonconamentwith any other We Bads. 3) Refer to girder(s) for thus to truss connectors 4) Provide mechanical connection (by others) of buss to bearing plate capable of withstanding 144 to uplift at joint 1, 91 lb upfift at joint 4 and 139 to uplift at joint 5. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 23 to down and 38 to up at 3-7-8, 31 to down and 47 to up at 3.7-8, and 51 lb down and 93 lb up at 647, and 56 to down and 97 lb up at 6-57 on top chord, and 4lb up at 3-7-8 , 6 lb down and 13 ID up m 3-7A, and 21 lb down at 6-5-7, and 24 lb doom and 21 lb up at 8S-7 on bottom chord. The design/selection or such connection device(s) is the responslb9ty of other 6) In the LOAD CASE(S) sector, loads applied to the face of the truss are noted as from (F) or back (B). LOAD CASE(S) Standard 1) Dead+ Roof Live (glanced): Lumber Increase=125, Plate Increase-125 Uniform Loads (ph) Vert 11=54,1-5=20 Concentrated Loads (lb) Vert 9=�(P=19, B=26)10=2(F=4, B�5)11=35(F=12, B=23) i J PE Z6051 d'e V Job N55 Inuss type yea Honer-I4 Ad 14MA CJ6 JAOC 4 7 Job Relevance (optional) boLNtlflice,rtrieix, FL, Jowl r .62MaNOV 302m]PnIhC 920pcNov 30an1 NtTCxhapus"'MM Fn Jul 611A0:162016 Pepei IMEaPOUhvCVVA016vrS07VTFdt?5dF3RdROPVMLYtRJOSDgi=yAmhJ2jh8;;tt_ �+ M+ 1R1{ 1 S" 1-9.14 3-0-8 2.9.15 f 01 i 1.4-4 1-614i 5.6.6 e-14 e-4-5 1f4 aSit 3-" Scale-1:16.7 Plate offsets (X,Y}- tz:0-0-B.at-7ZI, r/:a1-10,1-861, r/:0-0-0.0-1-lz LOADING SPACING- 2-01-0 CSL DFFL in pod) Udeft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.38 Vert(LL) .0.07 6.7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 125 BC 0.35 Vert(CT) -0.09 6.7 >834 180 BCLL 0.0 Rep Stress Ina NO NB 0.06 Horz(CT) -0.02 4 n/a nits BCDL 10.0 Code FBC2017/iP12014 Matrb(-P Weight 30 b FT =10% LUMBER - TOP CHORD 2x4 SP No2 BOT CHORD 2x4 SP No2 WEBS 20 SP No.3 REACTIONS (b/srze) 4=a3IMetilac CW, 5=1 o81Medmnira1, 7=25410-11-5 (min. al-8) Max Horz7=123(LC 4) Max UpldM=59(LC 4), 5=57(LC 4), 7-166(LC 20) Max Gmv4--95(LC 17), 5=108(LC 1), 7=254(LC 1) FORCES. (lb) - Max. CompJMm(. Ten. -All forces 250 (Ib) or less except when shovm. BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oo pumns BOT CHORD Rigid caging directly applied or 10-0-0 oc bracing. MTek recommends that Stabg¢ers and required cross braang be installed during truss erection, in aemrdance vdb Stabilizer Installation ide. NOTES- 1) %4Md: ASCE 7-10; Vult=160mph (3aecond gust) Vasd=124mph; TCDL=42psf; BCDL=5.0psL h=I511; Cat It Exp C; End., GCpr-0.18; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psi bottom chord Um load nonconcrmentwith any other live load& 3) Referto girder(s) for truss to truss connections 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 50 Ib uplift at joint 4,57 to uplift atjomt 5 and 168 b uplift atjotrd 7. 5) Hanger(s) drainer connection device(s) shall be provided sufficient to support concentrated load(s) 30 lb dawn and 110 lb up at 2-11-0, 30 to down and 110 In up at 2-11-0, and 26 lb down and 52lb up at 5-8-15. and 26lb down and 52 to up at 5-8-15 on top chord, and 71 lb up at 2-11-0, 71 to up at 2-11-0, and 5lb down and 2 b up at 5.8.15, and 5lb down and 2 to up at 5-8-15 on bottom tlwrd. The desig ilsdection of such connection device(s) is the responsibility of others. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as from (F) a back (B). LOAD CASE(S) Standard 1) Dead+ Roof Live (halanced): Lumber Increase=125, Plate Increase--125 Undomh I cads (Pit) Vert 14=-54, 1-5=20 Concentrated loads (Ib) Vert 6=72(F=36, 8=36)1 C=KF=47, B=47)11=3(F=2, B--2) PE6051 01 S Al tUF ///%/SSIOMA 1101 \\\\ .w k job Inuss two Ryan Homes-1452Ad 1452 A CJ4 JACK 2 1 Job Reference 'crud sow¢rh nuss,rcrvlm, ram, snw1 wxc ntuus nw aueulr mire elwsnw eu unrw,esi ,nc rn ax vi�:ur,vu,=ram, ID: PmCAMDCJGe1UC7720s-pu_ 1- A !1-"' 58-6 _ M1-9-14 1Q-13 25-11 LOADING(pst) SPACING- 24)-0 CSL TOLL 20.0 Plate Grip DOL 125 TC 0.37 TCDL 7.0 Lumber DOL 125 BC 0.32 BCLL 0.0 Rep Stress Incr NO WB 0.06 BCDL 10.0 Code FBC20177rP12014 Matrix-P Scale=1:129 DEFL- In (loc) 11defi Vd PLATES GRIP Veli(LL) 0.02 4-5 >999 240 hff= 2441190 Varga) 0.03 " >999 180 Horz(CT) -0.02 3 Na We IMaight 17to FT=10% LUN BER- BRACING - TOP CHORD ZO SP Not TOP CHORD Struchual wood sheathing directly applied or 68d oc purOns BOT CHORD 2x4 SP No2 BOT CHORD Rigid calling directly applied or 10-" oo bracing. WEBS 2x4 SP No.3 MTek recornmerMs Mat Stabilaers and reqused Coss bracing be installed during buss erection, in accordance with StabT¢er Installation cuide. REACTIONS. (Itds¢e) 3=53MIechaan-c4 4=21Meehanicdl, 5=187ra11-5 (min. 0-1-8) Max H=6=81(LC 4) Max Uptifl3=462(LC 20), 4=22(LC 17), 5=150(LC 28) Max Grav3=53(LC 1), 4-2g(LC 3), 5=187(LC 1) FORCES. (Ib) - Max. CompJN11m Ten. - AD forces 250 (b) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vut=160mph (3-second gust) Vasd=124mph; TCDL=42psf; BCDL=S.CW. "Sit CaL It Exp C; End., GCpi--0.16; MWFRS (envelope); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 pal bottom chord live bad nonconcurrent with any other We loads. 3) Refer to gWer(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to hearing plate capable of withstanding 82lb uplttatJoint 3,22 to uplift at joint 4 and 150 lb uplift atjdM 5. 5) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 30 )b down and 110lb up at 2.11-0, and 30 lb down and 110 lb up at 2-11-0 on top chord, and 71 m up at 2-11.0, and 71 lb up at 2-11-0 on bottom chord. The design/selection of such connection devica(s) is the responsibility of others. 6) In the LOAD CASE(S) Section, bads applied to the face of the truss are noted as frond (F) or back (13). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber 1nCease=1.25, Plate Increase=125 Uniform Loads (pit) Vert 13=.54,14=20 Concentrated Loads (b) Vert 6=72(F=36, B=36) 7--S4(F=47, B=47) r t ( 76051 , r 01 S Th-CyF S1lOfjll�l 1�?G\\\\\ ""�U