Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCERECEIVED Planning & Development Services Department Building & Code Regulations Division MAY 0 2 2019 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 46 -1553 ST. Lucie County, Permitting Certification for Design Load Compliance Project Name: COSCULLUELA SCANNED Project Address: 10701 S OCEAN DR LOT 857 R4 I "^B''OUilty Permit #: INSTRUCTIONS FOR USE: Type: Construction • This certification must be completed, signed, and sealed by the design profession � • Submit (2) copies for residential, (3) copies for commercial with all permit applic Io o New Residences (single or multi -family) REVIEWED FOR o Residential Addition CODE COMPLIANCE o Any accessory structure requiring a building permit o Any non-residential structure. ST. LUCIE.COUNTY * Note: Form not required for interior renovations provided that no exterior structural eleoe rofected d certain minor building permits at the discretion of the local building official. Contact the # above for questio DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed X Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D 4. Design Wind Velocity 165 mph _ASD X LRFD End Zone Width: 1 ft S. Mean Roof Height 5'+/-DECK HEIGHT ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone4:+80'6/-64.1 Zone 5:+70.11-74.5 Garage: 7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF Dock: 40 PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? _X­Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I-alsc`cert'iN that structural elements depicted on these plans provide adequate resistance to the design forces op . "-` %:l l sly . DANIEL PAUL RETHERFORD 72451 bbhh�� F =� y Print Name Cert # & Co. Cert Auth. 1402 HARTMAN ROAD, FT PIERCE, FL 34947 Company Name & Address y'f5 r • rj