HomeMy WebLinkAboutBLOWER DOOR TEST CERTIFICATESDate: 09/24/2019 Contractor: Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method Permit #: Job Address: 5259 Oakland Lake Circle SCANNED BY St. Lucie County SCANNED BY St. Lucie County Construction: ( ) New Construction — Complete ( ) Existing —After Addition House Infiltration Test Results CFM (50) = 1318 Volume = 15947 ACH (50) = CFM (50) x 60 / Volume = 4 Passing results must be & ACH (50) or less SLC Climate Zone 2 Test Date: 09/24/2019 Mec njcal ventilation required less than 3 ACH ( Vass ( ) Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: PEG LLC Address: 3975 Fair Ridge Drive I hereby certify that the above House Infiltr tion results demonstrate compliance with FBC Energy Conservation requirements innce ith Section O2A Climate Zone 2. Signature: Printed Name: OluWafeml Benedict License/Certification #: 0453377 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition OUAWNLU Jurisdiction: Permit #: BY St. Lucie County Job Information Builder: Ryan Homes Community: OAKLAND LAKE Lot: 57 Address: 5259 OAKLAND LAKE CIRCLE Unit: City: FT PIERCE State: FL Zip: 34951 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method Ila PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2. ® PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or R406-2017 (ERI), section labeled as Infiltration, sub -section ACH. ACH(50) specified on Form R405-2017-Energy Calc (Performance) or R406-2017 (ER& = 1,318.9859 X 60 + 15,947 = 4.9626 Method for calculating buildingvolume: CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans ❑✓ PASS ❑FAIL ® Code software calculated F_jWhen ACH(50) is less than 3, Mechanical Ventilation ® Field measured and calculated installation must be verified by building department. Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g. (50 Pascals). Testing shall be conducted by either Individuals as defined in Section 553.993(5) or (7), Florida Statues, or Individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third parry. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2.Dampers Including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3.lnterior doors, if Installed at the time of the test, shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems, if installed at the time of the test, shall be turned off. 6.Supply and return registers, If installed at the time of the test, shall be fully open. Testing Company Company Name: PEG Phone: 703-934-2777 1 hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: �L43 Date of Test: 09/24/2019 Printed Name of Tester: Oluwafemi Benedict License/Certification #: 0453377 Issuing Authority: RESNET