HomeMy WebLinkAboutBLOWER DOOR TEST CERTIFICATESDate: 09/24/2019
Contractor:
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phone:772-462-2165 Fax:772-462-6443
BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
Permit #:
Job Address: 5259 Oakland Lake Circle
SCANNED
BY
St. Lucie County
SCANNED
BY
St. Lucie County
Construction: ( ) New Construction — Complete ( ) Existing —After Addition
House Infiltration Test Results
CFM (50) = 1318
Volume = 15947
ACH (50) = CFM (50) x 60 / Volume = 4
Passing results must be & ACH (50) or less
SLC Climate Zone 2
Test Date: 09/24/2019
Mec njcal ventilation required less than 3 ACH
( Vass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Company
Company Name: PEG LLC
Address: 3975 Fair Ridge Drive
I hereby certify that the above House Infiltr tion results demonstrate compliance with FBC Energy Conservation
requirements innce ith Section O2A Climate Zone 2.
Signature:
Printed Name: OluWafeml Benedict
License/Certification #: 0453377
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
OUAWNLU
Jurisdiction:
Permit #: BY
St. Lucie County
Job Information
Builder: Ryan Homes Community: OAKLAND LAKE Lot: 57
Address: 5259 OAKLAND LAKE CIRCLE Unit:
City: FT PIERCE State: FL Zip: 34951
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method
Ila PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour at a pressure of 0.2 inch w.g. (50 pascals) in Climate Zones 1 and 2.
® PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
the selected ACH(50) value, as shown on FORM R405-2017 (Performance) or R406-2017 (ERI), section labeled as Infiltration, sub -section ACH.
ACH(50) specified on Form R405-2017-Energy Calc (Performance) or R406-2017 (ER& =
1,318.9859 X 60 + 15,947 = 4.9626 Method for calculating buildingvolume:
CFM(50) Building Volume ACH(50) ® Retrieved from architectural plans
❑✓ PASS ❑FAIL ® Code software calculated
F_jWhen ACH(50) is less than 3, Mechanical Ventilation ® Field measured and calculated
installation must be verified by building department.
Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure or 0.2 inche w.g. (50 Pascals). Testing
shall be conducted by either Individuals as defined in Section 553.993(5) or (7), Florida Statues, or Individuals licensed as set forth in Section
489.105(3)(f), (g), or (i) or an approved third parry. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2.Dampers Including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3.lnterior doors, if Installed at the time of the test, shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems, if installed at the time of the test, shall be turned off.
6.Supply and return registers, If installed at the time of the test, shall be fully open.
Testing Company
Company Name: PEG Phone: 703-934-2777
1 hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy
Conservation requirements according to the compliance method selected above.
Signature of Tester: �L43 Date of Test: 09/24/2019
Printed Name of Tester: Oluwafemi Benedict
License/Certification #: 0453377 Issuing Authority: RESNET