HomeMy WebLinkAboutENERGY EFFICIENCY CODES
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation -Reside ntiMeth d
Project Name: Land Trust 3107 Tropic Blvd
Builder Name: MAY
0 9 2019
IC
Street: 3107 Tropic Blovd. SCANNED
Permit Office:
City, State, Zip: Ft. Pierce , FL ,
BY
Permit Number: ST. Lucie County, Permitting
Owner: Land Trust 3107 Tropic Blvd St. Lucie CtJurisdiction:
Design Location: FL, Fort Pierce ouny
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing Existing (Projects
9. Wall Types (1184.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1184.00 ft2
b. WA
R= ft2
3. Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 2
d. NIA
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1160.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1160.00 ft2
6. Conditioned floor area above grade (ft2) 1160
b. N/A
R= ft2
Conditioned floor area below grade (112) 0
c. NIA
R= ft2
11. Ducts
R ft2
7. Windows(114.0 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 125
a. U-Factor. Sgl, U=0.79 106.00 ft2
.
SHGC: SHGC=0.45
b. U-Factor: Sgl, U=0.79 8.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.50
a. Central Unit
27.6 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d: U-Factor: N/A ft2
a. Electric Strip Heat
27.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.454
14. Hot water systems
8. Floor Types (1160.0 sgft.) Insulation Area
a.
a. Slab -On -Grade Edge Insulation R=0.0 1160.00 ft2
b. Conservation features
EF: 0.000
b. N/A R= ft2
c. N/A R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 39.08
PASS
Total Baseline Loads: . 43.01
1 hereby certify that the plans and specifications covered by
Review of the plans and
fUE S7gl�
this calculation are in compliance with the Florida Energy
specifications covered by this
04
__ ; ; OA
Code.
calculation indicates compliance
h ii„°'' s;.• o` yn
with the Florida Energy Code.
F nm = " „e
PREP E Y:
Before construction is completed
C
DATE:
this building will be inspected for
compliance with Section 553.908
4
0 y
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
!,),
with the Florida Energy Code.
G0 WE��
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
4/26/2019 10:30 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT ;_. AMARY CHECKLIST REPORT
PROJECT
Title: Land Trust 3107 Tropic Blvd Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1160
Lot #
Owner Name: Land Trust 3107 Tropic
Blvd Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
3107 Tropic Blovd.
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
Ft. Pierce ,
Family Type: Single-family
FL,
New/Existing: Existing (Projected)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1160 9280
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 FLORIDA ROOM
288 2304 No 2
1 Yes
Yes
Yes
2 DINING
110 880 No 0
1 Yes
Yes
Yes
3 KITCHEN
99 792 No 0
1 Yes
Yes
Yes
4 BEDROOM 2
110 880 No 0
1
1 Yes
Yes
Yes
5 BEDROOM 1
168 1344 No 0
1
1 Yes
Yes
Yes
6 LIVING
345 2760 No 0
1 Yes
Yes
Yes
7 BATH
40 320 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
FLORIDA ROOM 48 It 0
288 ft'
__
0 1
0
2Slab-On-Grade Edge Insulatio
DINING loft 0
110 ft'
0 1
0
3 Slab -On -Grade Edge Insulatio
KITCHEN 9 ft 0
99 ft'
0 1
0
4Slab-On-Grade Edge Insulatio
BEDROOM 2 21 ft 0
110 ft'
0 1
0
5 Slab -On -Grade Edge Insulatio
BEDROOM 1 30 ft 0
168 ft'
-_
0 1
0
6Slab-On-Grade Edge Insulatio
LIVING 25 ft 0
345 ft'
____
0 1
0
7 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
40 ft'
0 1
0
4/26/2019 10:30 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT !IMARY CHECKLIST REPORT
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested
Insul.
(deg)
1
Hip Composition shingles 1222 ft2
0 ft2
Medium
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1
in) Area
RBS
IRCC
1
Full attic Vented
150
1160 ft'
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) FLORIDA ROOM 30
Blown
288 ft2
0.1
Wood
2
Under Attic (Vented) DINING
30
Blown
110 ft2
0.1
Wood
3
Under Attic (Vented) KITCHEN
30
Blown
99 ft2
0.1
Wood
4
Under Attic (Vented) BEDROOM 2
30
Blown
110 ft2
0.1
Wood
5
Under Attic (Vented) BEDROOM 1
30
Blown
168 ft2
0.1
Wood
6
Under Attic (Vented) LIVING
30
Blown
345 ft2
0.1
Wood
7
Under Attic (Vented) BATH
30
Blown
40 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar Belo
Space
w
1
E
Exterior Concrete Block - Ext In§WORIDA RO
4.1 12
0 8
0
96.0 ft2
0
0
0.4
0
2
S
Exterior Concrete Block - Ext InEMORIDA RO
4.1 24
0 8
0
192.0 ft'
0
0
0.4
0
3
W
Exterior Concrete Black - Ext In§WORIDA RO
4.1 12
0 8
0
96.0 ft2
0
0
0.4
0
4
E
Exterior Concrete Block - Ext Insul DINING
4.1 10
0 8
0
80.0 112
0
0
0.4
0
5
E
Exterior Concrete Block - Ext InsuKITCHEN
4.1 9
0 8
0
72.0 ft2
0
0
0.4
0
6
N
Exterior Concrete Block - Ext InfiEDROOM 2
4.1 11
0 8
0
88.0 ft2
0
0
0.4
0
7
E
Exterior Concrete Block - Ext Infi&DROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
8
N
Exterior Concrete Block - Ext Infi&DROOM 1
4.1 12
0 8
0
96.0 ft2
0
0
0.4
0
9
S
Exterior Concrete Block - Ext InSffDROOM 1
4.1 4
0 8
0
32.0 ft2
0
0
0.4
0
10
W
Exterior Concrete Block - Ext InfiffDROOM 1
4.1 14
0 8
0
112.0 ft'
0
0
0.4
0
11
N
Exterior Concrete Block - Ext Insul LIVING
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
12
W
Exterior Concrete Block - Ext Insul LIVING
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
13
E
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
DOORS
#
Omt Door Type Space
Storms
U-Value
Width
Height Area
Ft
In
Ft
In
1
W Insulated LIVING
None
.32
3
6
8 20 ft2
4/26/2019 10:30 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R406-2017 INPUT t. .1MARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V #
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1
2
3
4
5
6
7
8
9
S 2 Metal Single (Clear)
E 4 Metal Single (Clear)
E 5 Metal Single (Clear)
N 6 Metal Single (Clear)
E 7 Metal Single (Clear)
N 8 Metal Single (Clear)
W 10 Metal Single (Clear)
W 12 Metal Single (Clear)
E 13 Metal Single (Clear)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.79 0.5 N 8.0 ft' 2 ft 0 in
0.79 0.45 N 18.0 ft' 2 ft 0 in
0.79 0.45 N 9.0 ft' 2 ft 0 in
0.79 0.45 N 9.0 ft' 2 ft 0 in
0.79 0.45 N 9.0 ft' 2 ft 0 in
0.79 0.45 N 9.0 ft' 2 ft 0 in
0.79 0.45 N 24.0 ft' 2 ft 0 in
0.79 0.45 N 24.0 ft' 2 ft 0 in
0.79 0.45 N 4.0 ft' 2 ft 0 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356
1082.7 59.44 111.78 .1233
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPA 27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit(
Split
SEER: 16 27.6 kBtu/hr
cfm 0.8 1
sys#1
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
System Model # Collector Model #
Collector
Area
Storage
Volume
FEF
ft'
DUCTS
/
V #
--Supply-
Location R-Value Area
-Return-- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
ON RLF
HVAC#
Heat Cool
1
Attic 6 125 ft'
Attic
45 ft' Prop. Leak Free Attic - cfm 34.8 dm
0.03 0.50
1 1
4/26/2019 10:30 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017
INPUT 7-_ ;WARY
CHECKLIST REPORT
TEMPERATURES
Programabl[e Thermosta[[t:]]Y
Ceiling Fans:
HeatiNov
ng [X] Jan [X] Feb
Mar
j
L
]
J Apr
May[
Jun
]
Jul
[ ]
[X] Aug
[X]
[ ]Sep
j [[X]]
L J
Dec
rr
Venting [[ ]) Jan [[ 11 Feb
X mar
Rl
May
Jun
EX]
) Jul
[) Aug
[ 1
Sep
Lxl Oct [X]
Nov
[ Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH) AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating(N/D) AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft'
0 ft
0.3
FLORIDA ROOM
Default(8 lbslsq.ft.
ft'
ft
0.3
DINING
Default(8 lbs/sq.ft.
ft'
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BEDROOM 1
Default(8 lbs/sq.ft.
ft'
It
0.3
LIVING
Default(8 Ibs/s .ft.
fl'
ft
0.3
BATH
4/26/2019 10:30 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 -AIR BARRIER AND INSULAIi__uI INSPECTION COMPONENT CRIT_--.A
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Land Trust 3107 Tropic Blvd Builder Name:
Street: 3107 Tropic Blovd. Permit Office:
City, State, Zip: Ft. Pierce , FL, Permit Number:
Y
Owner: Land Trust 3107 Tropic Blvd Jurisdiction:
w
Design Location: FL, Fort Pierce
_
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
/soffit
The insulation in an dropped ed ceiling/soffit
Y
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninina and wirina
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire qnrinkler cover plates and walls or ce lings
a. in addition, inspection of iog wars snau be in accorcance with the provisions of [CC-400.
4/26/2019 10:31 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL- DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 91
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. Existing (Projected)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
27.6
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1160
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.790
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.454
14. Heating system: Capacity
27.0
c) Area
7c.
114.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9C,
a) Electric resistance EF
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder
Address of New Home: 3107 Tropic Blovd. City/FL Zip: Ft. Pierce, FL
4/26/2019 10:30:66 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
+ wrightsofte
Project Summary
Entire House
QUICK CALCS, INC.
317 ST. LUCIE LANE. FORT PIERCE, FL34946 Phom: 772-466-6799 Email: QUICKCALCS@AOL.COM
Proeect Information
For. Land Trust 3107 Tropic Blvd
3107 Tropic Blovd., Ft Pierce, FL
Notes:
Job:
Date:
By.,
Design•
•
Weather. Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db
42
OF
Outside db
90
OF
Inside db
70
OF
Inside db
75
OF
Design TD
28
OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
grAb
Heating Summary
Sensible Cooling Equipment Load
Sizing
Structure
16443
Btuh
Structure
17799
Btuh
Duds
3304
Btuh
Ducts
4559
Btuh
Central vent (0 dm)
0
Btuh
Central vent (0 cfm)
0
Btuh
(none)
(none)
Humidification
0
Btuh
Blower
0
Btuh
Piping
0
Btuh
Equipment load
19748
Btuh
Use manufacturer's data
in
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
21239
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
3017
Btuh
1300
Btu
Central vent (0 cfin)
Btuh
Heating
Cooling
(none)
Area (ft2)
116
116g
Equipment latent load
4317
Btuh
Molume (ft)
10095
10095
Airchangeslhour
Equiv. AVF
0.45
0.23
Equipment Total Load (Sen+Lat)
25556
Btuh
76
39
Req. total capacity at 0.70 SHR
2.5
ton
Heating Equipment Summary
Cooling Equipment Summary
Make
Make Goodman Mfg.
Trade
Trade GOODMAN
Model
Cond GSX16S301A
AHRI ref
Coil ASPT30C14A
AHRI ref 201785795
Efficiency
100 EFF
Efficiency 13.0 EER,16
SEER
Heating
input
5.0
kW
Sensible cooling
19320
Btuh
Heating output
17105
Btuh
Latent cooling
8280
Btuh
Temperature rise
50
OF
Total cooling
27600
Btuh
Actual airflow,
311
dim
Actual airflow
920
dim
Airflowfactor
0.016
cfmBtuh
Air flow factor
0.041
cfm/Btuh
Static pressure
0.50
in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.84
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrlghts ft- 2019-Apr-2610g0:43
C ggtt-StibeDUriv ml20l9l9.0.01 RSU08101 Page 1
�� ...Doa ri9lWr1gfts0tHVACG107 TROPIC BLVD.np Calc=MI8 From Doorfawa: N
wrightsoft' Right -A) Worksheet Job:
Entire House Data:
QUICK CALCS, INC. By:
317 ST. LUCIE LANE, FORTPIERCE, FL34946 Phone: 772-466-6799 Email: OUICKCALCS@AOL.COM
1
2
3
4
5
Room name
EVOSEd wall
Room height
Room dimwsto
Roomarea
Entire Hmm
148.0 R
8.7 It
1160.0 ft'
FLORIDAROOM
48.0 it
9.0 it heatlood
120 x 24.0 It
288.0 IF
Ty
Construction
number
U-value
(BUAL'F)
Or
HTM
(BUM
Area (m
a perimeter (it)
Load
(BWh)
Area
or perimeter (fl)
Load
(BWh)
Heat
Cod
Gros
N/PIS
Heat
Cool
Gross
WPIS
Heat
Cod
6
11
ll4411
�---G
13A4as - - --�
1Aa1om
- -0.143
`1270
n-
_n_
a
a
a
_e
5
_s_
w
w
w
w
_ .-
-
-
--4.00
35.56
4.00
35.56
35.56
�35.56
4.00
` 35.56
4.00
35.56
35.56
__-- 10.92
_0.90
27.69
'- 2.19
34.77.
219
80.98
84.38
87.74
2.1g
_34.77
219
86.05
87.74
10.34
-_.. -
_ 1.66
_ 0.00
Y247
_�18
----- -50'1
'� 0
0
0
0
------0
0
- 229
___0
374
1
2
_ 1
- - 244
_ __8
325
2
1
21.__�229
__ �1160
148
917
640
1497
142
640
_640
-- 977
._.___284
1301
853
853
__1031
4098
l�R4/I
---G
W
Li
13AA=
1Aclom
1A-C1om
1Aclom-___-,_
13A4c
1Actom
13A-4=
1AClom
1Ac1om
11D0_�
16B�Oad' -
22A_tdi_
0.143
1270
1270
_-1270
0.143
1270
0.143
1270
1270
0,390
=0.032
0.989
414
4
18
_ 18
W- 252
8
_626
818
324
1518
1579
----534
__ -278
711
2065
2106
217
�1856
0
108
0
0
0
«0
108
0
0
r__0
-- 208
108
0
0
0
_288
48
_____0
432
0
0
0
-- - m
284
432
0
0
0
_._�258
1329
_--_
236
0
0
0
--455
___278
236
0
0
_ --0
. _ 461
0
- 276
8._._-8
108
0
0
0
_288
288
394
24
24
21,-_.
___1166
1160
C.�
F
FT-
6
C)AED exalrson
417
1
-268
Envelope losrgain
14114
13551
3569
1399
12
a) Infiltration
b) Room v Iilafion
2330
0
638
0
770
0
211
0
13
Internal gains O-pants@ 230
Applianossfather
7
1610
2000
4
920
0
Subtatal(Iines6to 13)
16443
17799
4340
2530
14
15
Lesebemalload
L?stransfer
Redsfiibuton
Subtotal
Ductloads
20%
26%
0
0
0
16443
3304
0
0
0
17799
4559
20%
26%
0
0
0
4340
872
0
0
0
2530
Us
Total room load
Airrequired (dm)
19748
311
22357
920
5212
82
3178
131
Calculations approved bVACCAtO meet all requirements of Manual J 8th Ed.
A -rk- wrlglrrtaoR' 2019-Apr-2610.40A3
Right-SuleOUNvema1201919.0.01 RSU08101 Page l
...D0=ehslWrigMoftHVACa107 TROPIC BLVD.Ap Calc=MJ8 FmrtDoorfaces: N
WA
W
N
m
+• m
mAWN+
p1
��
04111
W
5
�
3.d.
�
.9.
o
I
.III
I I
1
i
it
I III
� III
I 1 1
ii
!,�I�
�
I!
I I
iII
I i l
1.;1►,1�__
'n ICI
I I
�_�_s�I
�
�
."OAAA
��� �
gag=���
�
Ij
3
m
I
III III
��
if 33
8
6
Iji
fI
I
IIi
li'
ill
4
F
W
l!
i
11333 I9I
�n 1 I
j
!i
IlIII
I
II
�i
IIi
Iitl
�i
II. l
'
I
I
i
m
`�
!IIi;111'III!ilili!IIIIiI(III!iIIIII�i'I�ff�;��h���;��
I
II
I I�l
�I:lI
1i'II1•
I
iII
,I.
,I I 1 Ix
I
YliAYII AIr pYltAb"i
i�81S 99 998"p9'@ 99S1
e
' ' I
I
I1WW 'mm I
I
I i
1
i
I
I I
I I; I
1"0V1 lV>ON�N
ig olAAtOii m�,V mA�nm�O,�l aol
Y.
ili
IfI
ilia
Ill�f
.i
jIl'II�I
j I ��
�
OOOOlO00000)00!
�r
v
l
t
�o h�000
00
0$
m
j i
I I i I I
l i
I
j l
1
1 I i l I
i I I
1
I o{o o'�oobo""o o'
I`I�i
1
�
o
i I
� I
I'
I
I
'I
�Ill�iiiili
t
I
1 !lili�mlm
I
I I m I
�m m0000000m o+o o.
3,�
m
o 0
1
1){{
I
l
1
I 1
I�OOOOIOO
1 ! + I
I I f! I 1 f i
JUI
INO 01000
OI
00
0o
OI
tm0
{
I {
O o�Oom{00
W1
L2
wrightsoft Right-J(9 Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 P1nre: 772-466-6799 Email: OUICKCALCS@AOL.COM
1
2
3
4
5
Room name
EN)osedvall
Room height
Room dimensions
Room area
BEDROOM2
21.0 ft
9.0 ft heaVood
10.0 x 11.0 ft
110.0 ft2
BEDROOMI
30.0 It
9.0 It heaV000l
14.0 x 12.0 ft
168.0 fe
Ty
Construction
number
U-value
(BtrrhM�°F)
Or
HTM
(Btu NO
Area (M
or perimeter (ft)
Load
(BUh)
Area (1P)
or perimeter (ft)
Load
(Btuh)
Heat
Cod
Gros
N/P/S
Heat
Cod
Goss
N/P/S
Heat
Cod
6
11
L-G
1Aciam_-_ _
13A-4=
1A-clom
1Actom
1Actom
1Actom
13A-4=
1A-dom
1A-dom
11D0_ __
jffls- d'__
22A-tol_ _ __
'---0.143
_.,_1270
0.143
1270
1270
1270
�1270
0.143
1270
1270
_0.390
___0.032
_0.989
n
,n_
a
a
a
_e
_.s_
w
w
w
w
__
-
--- 4.00
_.35M
4.00
35.55
35.56
_ 35.56
._35.56
4.00
35.56
35.56
_10.92
_0.90
27.69
2.18
__34.77.
219
80.98
84.36
87.74
219
34.77.
219
86.05
87.74
10.34
1.60
0.00
' --99
_-.9
90
0
9
0
0
--0
0
0
0
0
.�110
110
------90
- 0
81
0
1
0
0
_--0
0
0
0
0
=10
- .21
360
_�320
324
0
320
0
0
-_0
0
0
0
0
=99
582
197
-__.313.-__
177
0
759
0
.0
_ -0
0
0
0
0
_-176
,_ 0
-'- 108
9
0
0
0
0
--- _ _99
0
_-- _ 996
__._320
0
0
0
0_
.-_ 144
. _._ --0
408
853
0
0
=131
831
y-_"- 217
---313
0
0
0
0
'~ 79
._. __ 0
223
2065
0
0
_ 269
0
.
�-_G
jg
0
0
0
0
_- ___0
102
2
0
0
.__✓.
� ,_.,0
125
24
0
0
_188
F___
=168
30
__ 168
6
c)AED elmrrsion
-186
617
Emelope losstgain
2005
1436
3104
3783
12
a) Infiltration
b) Room venfilafion
337
0
92
ol
481
0
132
0
13
Interval gains Oovpants@ 230
Appliarg bthel
1
230
0
1
230
0
SubNlal Qines6 t113)
2342
1759
3585
4144
14
15
LesseMenal load
Lesstransft;r
Redieribuficn
Subtotal
Ductloads
20%
26%
0
0
0
2342
471
0
0
0
1759
450
20%
26%
0
0
0
3535
720
0
0
0
4144
1061
Total room load
Air mquired(rirn)
2812
44
2209
91
4305
68
5206
214
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
wrigAeooPt- 2019-Apr-2610:40:43
---- Riglt-Suta0Unversa1201919.0.01 RSLI08101 Page
...D0w errs\Wrigltsoft HVACL3107 TROPIC BLVD.Ap CaIc=M18 Frort Doorfaces: N
t
wrightsoft• Right-JU Worksheet Job:
Entire House Date:
Br•
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORTPIERCE, FL34946 Phone: 772466-6799 Email: QU1CKCALCS@,AOL.COM
1
2
3
4
5
Roan name
FVwedvdI
Room height
Roan dimensions
Room area
LMNG
25.0 it
8.0 it heatl000l
1.0 z 345.0 It
346.0 4'
BATH
5.0 it
9.0 It heallmol
5.0 K 8.0 it
40.0 1P
Ty
Cwstrucdon
number
U-value
(BCihtft�°F)
Or
HTM
(Btrrhffl
Area (f?)
a perimeter (f)
Load
(Btuh)
Ana (R"`J
or perimeter (it)
Load
(Btuh)
Heat
I Call
Gross
Ner.
Heat
Carl
Gross
WP/S
Heat
Cool
8
11
lt�1
_!-C
13A406
1Ac1= ___.
13A-4ocs
tAc1=
1Ac1om
1Ac1ao _ _
13A-floc _ _
1Aclan
13A4acs
1A-clan
1Ac1an
16B,30atl_ -
22(Nd __
0.143
__1270
0.143
1270
1270
1270
0.143'
_ _ 1270
0.143
1270
1270
0,390
_-0.032
_ _ 0,989
n
_n_
a
a
a
a
S
_s_
w
w
w
w
__4
.00
_35.56
4.00
35.58
35.56
35.56
_4.00
_35.56
4.00
35.56
35.56
10.92
_0.90
_ _ 27.69
__
210
-_34.77.
219
80.98
84.36
87.74
2.10
_34.77
219
86.05
87.74
_10.34
_7.60.
_0.00
40
___ _0
0
0
0
0
__0
__ __0
160
0
24
21
346
345
40
___ ,.0
0
0
0
0
160
___0
0
0
0
0
____0
_.___0
460
0
853
229
.__309
692
' 88
____0
0
0
0
_0
_-_ 0
___0__
252
0
2106
__�,217
__552
0
0
_.____.0
45
4
0
_70
0
__0
0
0
0
0___00
- 40
40
0
_.,__0
41
1
0
_0
___ 0
____0
0
0
0
_._ 40
5
0
___0
164
142
0
0
___. _ a
__.._.__0
0
0
0
__36.
138
0
_____0
90
324
0
------0
0
_____-0
0
0
0
0
____64
- 0
____0
0
115
0
1
21
_ _345
25
_11D0_
C_
6
c)AED elalrsion
645
47
Enelope lossfgmn
2705
3858
481
431
12
a) Infiltration
b) Roc r %enlilafon
357
0
98
01
80
0
22
0
13
h1emal gains Oavpants@ 230
A.ppliarms/other
1
230
0
0
0
0
Subtotal (lines(ito 13)
3061
4186
561
453
14
15
LesseMemal load
Lesstransfer
Redistributon
Subhrtal
Ductloads
20%
26%
0
0
0
3061
615
0
0
0
4186
1072
20%
26%
0
0
0
561
113
0
0
0
453
116
Total room load
Airrequired(c1m)
3676
58
5258
216
674
11
569
23
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-Fk- wrtgheooit- 2019-Apr-2610:40:43
A& Rinht-S1ite®Uriversa1201919.0.01 RSU08101 Page
m ...Doaerts%Wdgltsof1 HVAC13107 TROPIC BLVD..np CaIc=M18 FrartDoorfaees N
Duct S stem Summa Joei
wrightsoft° Y rY oa,,3:
Entire House By.
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Pture: 772-466,6799 Emit: OUICKCALCS@40L.COM
Project• •
For. Land Trust 3107 Tropic Blvd
3107 Tropic Blovd., Ft Pierce, FL
External static pressure
Pressurelosses
Available static pressure
Supply/return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.349/0.151
in H2O
0.080
in/100ft
311
chn
169 ft
Cooling
0.50
in H2O
0
in H2O
0.50
in H2O
0.349/0.151
in H2O
0.080
in/10011
920
cfm
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(dhn)
Clg
(Ctm)
Design
FIR
Diam
(in)
H x W
(in)
Dud
Mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
c 569
11
23
0.080
4.0
Ox0
VIFx
22.2
90.0
st1
BEDROOMI
c 5206
68
214
0.080
7.0
Ox0
V1Fx
26.8
90.0
st1
BEDROOM
c 2209
44
91
0.080
7.0
Ox0
VIFx
27.7
90.0
SO
DINING
c 2363
28
97
0.080
7.0
Ox0
VIFx
6.1
70.0
FLORIDA ROOM
c 1589
41
65
0.080
6.0
OxO
VIFx
7.8
70.0
FLORIDA ROOWA
c 1589
41
65
0.080
6.0
Ox0
VIFx
10.0
70.0
KEN
c 3575
21
147
0.080
7.0
Ox0
VIFx
16.7
90.0
st1
LMNG
c 2629
29
108
0.080
7.0
OX0
VIFX
16A
90.0
st1
LIVING -A
C 2629
29
108
0.080
7.0
OXO
VIFX
4.2
70.0
Supply Trunk Detail Table
Name
Trunk
Type
Htg
(dm)
Clg
01711)
Design
FIR
Meloc
Opm)
Diam
(in)
H x W
(in)
Dud
Material
Trunk
st1
PeakAVF
172
584
0.080
743
12.0
0 x 0
VinlFlx
WrIghtnoft• 2019-APr-2610:4593
••••+•..�-,�., RigF&SUta8UNvemI201919.0.01 RSU)8101
Page 1
..DJaillerts\Wrigttsoft HVACZ1077ROPIC BLVO.np CaIc=MJB Frort Doorfaces N
Return Branch
Detail
Table
Grille
Htg
Clg
TEL
Design
Vtiloc
Diam
H x W
Stud/Joist
Duct
Name
Size (in)
(cfm)
(cfm)
(ft)
FR
(tpm)
(in)
(in)
Opening (in)
Mat
Trunk
rb4
Ox0
57
205
51.0
0.296
192
14.0
Ox 0
VIFx
rb2
Ox0
123
329
0
0
0
0
Ox 0
VIFx
rb1
Ox0
82
131
0
0
0
0
Ox 0
VIFx
rb3
Ox0
50
255
0
0
0
0
Ox 0
VIFx
* wr'igh[5oR' 2019-Apr-2610.45.03
ACCA ....,+• .,...,ram.,„ RigN-SUk8Uriversa1201919.0.01 RSU08101 Paget
...Do=ertslWNgWS ftWACZ107T20PICBLVD.sW Calc=MJB Fmd Doorfaces: N