HomeMy WebLinkAboutLOAD CALCULATIONSOptional Load Calculation
Heat Larger Than Air
`l o
SF x 3VA Living Only
=
(2) Small appliance ckts @ 1500VA each
= 3000
Refrigerator @ 1500
Refrigerator @ 1500
= 1
Freezer @ 1500
=
Washing Machine @ 1500
= I�
Dishwasher @ 1500
=
Disposal @ 1500
_
Mini Sewer @ 1500
=
Clothes Dryer @ 5000
Range @ 12000
Water heater @ 4500
Fixed microwave @ 1500
= I SGL1
Vacuum @ 1500
=
Trash Compactor @ 150D
=
Pool Heater @'name plate'
_
Spa @'name plate'
Motors 746VA per HP
Opener
Garage Door
-
i) Total
2) First 10 KVA of general load @ 100% = I p G0o
3) Subtract line 2 from 1 = h 7 7
4) Multiply line 3 @ 40% = R 3U
5) Add lines 2 and 4 ='S
6) 60/S0amp breaker for heat (10000)
7) 40/30amp breaker for heat (5000) _ `-
8) Total heat -Add lines 6 and 7 = '
9) Multiply line 8 @ 65% _
10) Add lines 5 and 9
11.) Divide line 10 by 240
Summary:
Line 10 is the total KW
Line 11 is the total Amps
SCANNED
BY
St. Lucie County
ST.LUCIE COUNTY
PLAN REVIEW
BLDG:
DATE:
DATE:—'
PLUMB:
DATE:
MECH:
DATE:
/ (D3o. S (Generator Size Needed)
IV L/ 5. i. v2 (Breaker size Needed)
FILE C®PY