Loading...
HomeMy WebLinkAboutSCRENROOM ENCLOSURECORNER POST -fAVE RAii'1 -' ` _ ��' \G .BEAM -STITCHING SCREVS SW (11 TOTAU SAS AS SHOWN ( MIN:; /SPLtLE-PEAL •!` 6I V x2'O.B - :. PATIO SECTION PLATE EDGE DISTANCE 6 SPACE SCREWS - A ,.: A !' - 5052-H32 Al. C-C FASTENER SPACING) -- O_ EQUALLY (TYP.) _ - ' e 6' x 5' x 0.050' COL M" 0.,(. • / <„` e 6063-T6 ALLOY PLATE �4 -' 0 IME SIDE) OR STRONGER NAB. A� K-BRACE 3- x 3- x 0.050• HIN. 6063-TG ALLOY PLATE OR STRONGER (ONE SU)D,WITH 200.070 CHAIR PAIL (3) - 612 x 34' SITS, EACH SIDE ASSHOWN (V (V MIN PLATE EDGE DISTANCE K-BRACE L C-C FASTENER SPACING)R,s 16O6'3-T6 K-BRACEDo1HP03' x 2' x 0E OR NINER ALLOY PLATE OR STRONGER ,4, (ONE SIDE) es"IIII////y i 1W f0 (3) - e12 x %. SN.S. K-BRACE (� (9N s>` l 0\4x 1� J s� 4 EACH SIDE AS SHOWN ♦ p ( MIN. PLATE EDGE GIRT (CHAIR RAIL) r R JaEN ` WAA FASTENER SPACINLI a1F- x 2• ROLE PLATE L IN EU DFRT P. Y'' OETE R PLACES) OR CONCRETEII SCREWS-FDR,CORNFR COLUMN LATERAL "K" - BRACING CONNECTION DETAILS ES (I2x]/4' SAS 1.2 O.B. ATTACH . Ix5xW ANGLE 6' LONG r EO(TOBEAM W/ r(TYP. B EACH BEAN) (2)-/1DK2' s.Ms. wro scREw Boss � I "lam. (4) Q12x3/4' SAS. 4 ,ROOF BEAM Q,(FNT OR SLOPED) 11(1)-yam• 2 FOR 2.8 (4) #12x3/4" EACH LEG. -(2) Y(0x3- LG R EACH ANGLE ". NOTD PRIMARY-'. ATTACHED TO HI CONVENTIONAL FACIA TO BE 2x6 WIN) SPF. OVERHANG NO 7 I� OR ULSTER RED CEBAR NOTED ON PLAN STRUCTURAL RED 2 HIM. (U Y'Ox2' LG. LAG SCREW B 24' O.C. ENTIRE LENGTH OF GUTTER SECURE FASCIA TO EACH RAFTER TAIL W/ (D $'0x4' LONG PAN HEAD LAG SCREWS BEFORE ATTACHING SUPER GUTTER C❑R) ROOF BEAM TO SUPER GUTTER CONNECTION DETAIL ®12' D.C. TOES (D V'0x2' LG. LAG SCREWS (TYP. B EACH BEAN) lx2. 01 (D Y12x2' SAS B 12' 0, IQ Q (MM) BETWEEN BEAMS 0. ANGLLE CONTINUOUS SECURE FASCIA TD EACH RAFTER TAIL (D Y'ex4• LONG PAN HEAD LAG SCREWS BEFORE ATTACHING SUPER GUTTER Y' CONTINUOUS BEAD OF CONSTRUCTION ABHESIVE 1x1A' BY 2" LONG - MGLE EACH SIDE ()YP.) (4) 01441" S.M.S., 2 SCREWS EACH LEG (TTP.) HOLLOW POST — BE� CHAIR RAIL / GIRT TO POST JCONNECTION DETAIL 2. PURUN' (MAY BE SLOPED'`- THRU. 2.3 URI-N WREW s" .S. O 24" O.C. IQ O.B. TO 2.3. B 24- D.E. B14x%' SCREWS d) QK) Pv) (n)(xD BEAM LINE LINE SCREWS PLATE 'A' 'B'W'C' TOTAL WIDTH 2x4 3 2 24 12, 2x5 3 3 32 14- 2x6 4 3 40 14- 2x7 5 4 56 l6' fiRm w A 5, 64 Ifllb' 2x9 5 6 72 18' 2x9(1W) 6 7 88 1 18' 2xI0 17 7 1 96 (3) 1124- S.M.S., EACH LED AND rMIN. (4) 8104' LONG SAS. IWO (6) 012,A- S.M.S. CHANNEL TO BEAM / SCREW BOSSES (IYP. ALTERNARYE) (9) SCREW TOTAL / BEAM STITCHING O 24' O.C. (TP. TOP AND BOTTOM OF SMB 2.3vD.07U1 SEE TABLE FOR SIZES) I'x 1'x3"LG. I(ATWE) M PURLIN TO ROOF BEAM CONNECTION DETAIL lxlxt§" BY 3' LONG ANGLE, EACH SIDE (TYP.) LED (6roTAL .(TYP.) N 2x34.045 FAVERAIL ATTACHED TO^--�.-.,- BEFNS WITH (3)-/IOx2- SM.S� - Qd= ,.`SN.B. BEAM INTO SCREW 805S. ()> "MAY BE SLOPED OR MT <v SEE\PWI FOR 512E7 V1 �V( ANGLE-' WIDE WITH- -14x1'„INiO BFNM k (2)-814i1� (+" XTOS.N x2 0.84TO 2.3. B� cm.) EACH SHOE. 012-31" S.M.S. EACH WE BEAN FOR 2x5 COLUMN TO BEAM Ys• HIN, 3 %. MAIL C-C SPACING OF FASTENERS (TP.) DISTANCEE(AMP ➢GE St. MAIN POST / COLUMN TO ROOF BEAM CONNECTION DETAIL=� DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 ISSUED J_ Q H- W U � C — UU o Z) U co C 0 d Z 1) UU !A Z c Z a ~ co J WU U (n a U ❑ DRANT) BY: DYK CHECKED BY. DYK DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM AS IATES, LLC Aq 26 7 P ux 1 039 Tam F 9 if 1 /S Drawing No. - 060811 SHEET 1OF3 3' MIN. PURLIN SUE' COW I�GIE�, EACH SIDE MP.) 2.2.1/8' . 2- LG. ANGLE S.M.S. WITH MIN. NCCR&TE ANCHOR % � W/ (4) 0120/4• S.M.S EDGE DISTANCE W/2%t'EMSEOMENT INm (}I la (EACH SIDE) SmUCN CONCRETE (i ., EE NOTE 1 N• 0 O %-0 CONCRETE ANCHOR J 1'y2. OS, SO TE O O W/2%m EMBEDMENT INTO + 21 PURUN STRUCTURAL CONCRETE (EACH SIDE) rr ?. V SIDEWALL COLUMN TO CONCRETE CONNECTION DETAIL SEE PLAN FOR SIZE 1.2 O.B. ZASTENED TO COME SEOOON YTN /1401Y' S.M.S., MIN. EMBEDMENT � E`OCE OF CONCRETE --Y —1-i `�•" w;U 4 PLAN VIEW uoZ Yg' ANGLE, EACH SIDE (TYP.) %'0 CONCRETE ANCHOR W/2)6' EMBEDMENT INTO STRUCTURAL CONCRETE (TYP.. SEE NOTE 10) �174' O.B. SOLE PLATE 'l $ 3- MN. (M.) Y0 0.2Vm CONCRETE SCREW ANCHOR O 26' O.C. zu� AND 9' FROM POST OYP.) ado s111M EDGE OF CONCRETE —I I V (TYPJ PLANVI_AEW MAIN COLUMN TO CONCRETE CONNECTION DETAIL -, 0.8. SOLE PLATE (TYPJ�N BUM MAY BE MT OR SLOPE[ 244- ANGLE CUP, CUT AT 4', Ix3 O.B. FASTENED TO CORNER' A 45 (+/-) ANGLE AND j,I SECTION WTIH /10.2' S.M.S. W/ ATTACHED TO THE SCREEN ROOF 1 UTA HER (2 WASis. O.C. BEAM WITH ONE (1) Y.'0 THRU- I•I BOLT, WITH FENDER WASHER. ATTACHED TO BEAM OR CAVE ML DIAGONAL GRACING SHALL NOT BE ATTACHED TO ROOF PURUNS. 1I +2)-614 RAIL AND (2)- THE CORNER POST L-1.2 O.B. TOP FRAME CORNER POST -IA O.S. SIDE WALL CORNER UPRIGHT Rµ ELEVATION VIEW CORNER POST/COLUMN UPRIGHT DETAIL THICK BRICK PAVERS f9_{_TAR ON TOP OF MOTOR OR. SOLE PLATE 2: N A Y.',0.5- CONCRETE SCREED'S O 26' O.C. `2i0' NIA. CONC. (TY➢.), %- CONC. EMBEDMENT (MIN.) EMBEDMENT (TYP.) TYPICAL FRONT VIEW OF POST TO FOUNDATION CONNECTION WITH PAVERS 4' NOMINAL CONCRETE SLAB WZ500 PSI, MIN.) W6AxIO W.M. OR FIBER RONFWMEDO [POLYPROPYLENE FIBER - 1.5 POUND (MWJPER C.Y.] •a. . d e.. .4. .a • `UNDISTURBED SOIL OR COMPACTED CRUSHED UMEROCK (90% PROCTOR) MIN. (1)-/5 REBAR CONTINUOUS. SPUCE NUST OVERLAP 2O' MIN. 3- COVER (TVP.) ° a 'd APPROXIMATE GRACE e ° 0 4 4 4 n PSI MIN. CONCRETE STRENGTH DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 ISSUED J COMPACTED OR UNDISTURBED SOIL/SAND = F—¢- UJ (1)-05 REBAR, CONTINUOUS C 3' MIN. CONIC. COVER, 36' MIN. W LAP SPLICE 0Of C 0 1 1�i N Z U W Z MIN. CONTINUOUS PERIMETER FOOTING aa) LU C Z (L O Co J Z U U EHBEAM ALTERNATE (1) Lu ' 2xb}$" ANGLE U Q (4) Al2A S.N.. BRACE DRAWN BY: DYK 2'.. PURUN } 2'x1'45' ANGLE (BRACE) W/ q 1 CHECKED BY: DYK SCALE: AS SHOWN (4) 8121�%• INS. o EACH I BEAM MAY SE'FAT OR SLOPE[ ( YP. EACH W10.38 EACH PLAN - TYPICAL ROOF BRACE TO BEAM CONNECTION 1 ANGLE 2' LONG ON 4 DEW/(4) /12.'� G.M.S LEC (BEAM h BRACE) (RACE PLAN) ALTERNATE (2) 2.3 BRACE DO YEON HIM, P.E. FLA. REG. NUMBER 49497 DO KIM A SOCIATES, LLC- IW 26887 spEarTM39 Tampa. FL 33679 FOUNDATION/SLAB OETAIL Drawing No. - 060811 SHEET 20F3 1y6lcraf Notes and Specifications: 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2. Concrete shall be minimum 28 day compressive strength of f'c=2500 psi, and be in accordance with the requirements of ACI 318. Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with ACI 318. 3. All dimensions are provided by contractor, DO Kim & Associates, LLC have made interpretations where necessary. 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host structure capacity. 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Aluminum shall be 7005-T53 Alloy, 6005-T5 Alloy; for secondary components 6063-T6, Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. 6. Unless otherwise noted, SMB shall be stitched with #100/4" SMS at 24"o.c., top and bottom. i. Connections using screw bosses shall have minimum (4)-#10x2" per connection unless "shown otherwise. 8. Unless otherwise shown, screws shall have minimum edge distance and center -to -center distances as shown in this table. C-1022 Low Carbon Steel SMS & Self -Drilling (TEK) Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) Minimum Edge Distance Minimum Center to Center Distance #10 0.188 s/„' /2" #12 0.219 3/e" q/,c" #14 (1/4") 0.250 1/2" s/8" 9. Structure has been designed to meet the 611 Edition FBI (2017 FBC). Project is sited where the ultimate design wind speed, Vet, is 150 mph (3-sec gust) for risk category I buildings and other structures. Exposure C. Design pressures are from Table 2002.4, 2017 FBC reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (ASO). 10. Concrete anchors may be "Large Diameter Tapcons" (LTOs), Tapcon concrete screws, Simpson Strong -Tie Anchors or Titian Screws or approved equal. 11. Screen enclosure structure shall meet Section 454.2.17 Residential Swimming Barrier Requirements and the screen enclosure per 454.2.17.1.11. if enclosing a pool. DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 ISSUED W J W w U ❑ C w CCl) O Z U w Z a� w c z of a o = J Z U U w m a U O I CHECKED BY: DYK I DO PEON KIM, P.E. FLA. REG. NUMBER 49497 DO KASSO IAT S, LLC 88# 7 P T'13 00 9 I3 a, i I Drawing No. - 060811 I SHEET 3OF3