Loading...
HomeMy WebLinkAboutD O H PAPERWORKSTATE OF FLORIDA _ DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM '.Y CONSTRUCTION INSPECTION AND FINAL APPROVAL wc� APPLICATION #: API 159393 PERMIT #:56-SF-1559475 DOCUMENT #:FI1044493 DATE PAID:09/10/2014 FEE PAID:515.00 RECEIPT #:56-PID-2511810 APPLICANT: Rodolfa Vega and Carmen Hernandez AGENT: Roland Rollins SGAAINEE). PROPERTY ADDRESS: 904 Osceola Dr Fort Pierce, FL 34982 p�7 RV LOT: BLOCS: St Lucie Count • SUBDIVISION: xD#: 3409-411-0004.000-4 'lJ 11/ CHECKED [Xl ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [011 TANK SIZE [1] 1537.00 [23 [ ] [271 SURFACE WATER FT [ ] [021 TANK MATERIAL Polyethylene [ ] [281 DITCHES FT [ ] [031 OUTLET DEVICE [ 1 1291 PRIVATE WELLS 90 FT [ ] [043 MULTI -CHAMBERED [L_12 N ] [ ] (301 PUBLIC WELLS FT [ 1 [053 OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT I 1 [061 LEGEND 1. 70VA43-16DC4 2. [ ] [321 POTABLE WATER 25 £T [ ] [071 WATERTIGHT [ 1 [331 BUILDING FOUNDATIONS 7 FT [ ] (081 LEVEL [ 1 [341 PROPERTY LINES 18 FT [ ] [091 DEPTH TO LID [ 1 [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [1] 1080 [21 SQFT [ ] [361 DRAINFIELD COVER [ ] (113 DISTRIBUTION BOX HEADER x [ ] [371 SHOULDERS ' [ ] [123 NUMBER OF DRAINLINES 1. 15.00 2. [ 1 [381 SLOPES [ 1 [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 03/18/2016 [ 1 1143 DRAINLINE SLOPE [ 3 [157 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 16_00 [ ] 1403 UNOBSTRUCTED AREA I 1 [171 SYSTEM LOCATION [ ] [413 STORMWATER RUNOFF [ 1 [181 DOSING PUMPS 1.00 [ ] [421 ALARMS [ 1 [191 AGGREGATE SIZE [ 1 [431 MAINTENANCE AGREEMENT [ 1 [20] AGGREGATE EXCESSIVE FINES [ ] 1441 BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL 1 1 [463 FINAL SITE GRADING [ 1 [221 FILL AMOUNT [ ] [471 CONTRACTOR Abner Leyva(Leyva Plumbin [ 3 1231 FILL TEXTURE [ 1 1481 OTHER INFILTRATOR Quick4 EQ36 (single [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] [253 AREA REPLACED [ 1 [491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [501 TANK CRUSHED G FILLED Cc —ants: Comments are on pass 2. CONSTRUCTION I APPROVED / DISAPPROVED ): FINAL SYSTEM [ AppROVED / DISAPPROVED ]; (Explanation of violations on fallowing page) St. Lucie CHU DATE: 11/09/2015 DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, SAC EH Database v 1.0.1 AP1159393 EID1559475 CUD DATE: 03/18/2016 Page 2 of 3 n+ssr+F APPLICATION #.AP1159393 STATE OF FLORIDA PERMIT #:56-SF-1559475 DEPARTMENT OF HEALTH DOCUMENT #:FI1044493 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:09/10/2014 FEE PAID:515.00 RECEIPT #:56-PID-2511810 Violation Number Comment Comments The system is sized for 5 bedrooms with a maximum occupancy of 10 persons (2 per bedroom), for a total estimated Flow of 580 gpd. No violations, system ok to cover. Contractor notified onsite. NEEDS FINAL INSPECTION FOR STABILIZATION AND ALARMS. Final inspection ok emailed.to contractor and to SLC building DR 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Dambnso v 1.0.1 AP1159393 EID1559475 STATE OF FLORIDA /�7C DEPARTMENT OF HEALTH PERMIT ] . -� - 1 �yq T J "' ^! ONSITE SEWAGE ij1RF'a1 MElNT AND DISPOSAL SYSTEM ^�yc' SITE EVALUATION AND SYSTEM SPECIFICATIONS • . ....U": SUBDIVISION: I :OPERTY ID a:�4f fl-, i (I "&oYl'opn^[Section/Township/Parcel No. or Tax ID Number] BE COMPLETED BY ENGINEER, HEALTH'DEPARTMENT EMPLOYEE, OR OTEER QUALIFIED PERSON. ENGINEERS ST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE AT,L ITEMS DPERTY SIZE CONFORMS TO SITE PLAN: YES [ ] NO NET USABLE AVl+TT•AnLE: SS ACRES TAL ESTnQaRD SEWAGE FLOW: GALLONS PER DAY SIDENCEA=LE _/OTHER-TAIME2] THORIZED SERAGE BLOW: GALLONS PER DAY • FIB 'ACNE OR GPD A DBSTRIICTED AREA AVAIL -ABLE: �,5(L}ij SQFT UNOBSTRUCTED AREA REQUIRED: SQFT :2CHMARK/REFERENCE POIrIT LOCATION: „kA vM. " Ii M 'sVATION., OF PROPOSED SYSTEM SITE IS_ 1(o [Il4 /FT] MINIMUM SETBACK WHICH CAN BE igyINmAXNED PROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES MACE mama:�_FT DITCHES/SRAIES:. 1�] FT NORMALLY WET? [ ] YES _[ ] NO ME: PUBLIC: FT LIMITED USE: FT PRIV-ZM. `75 FT NON. -POTABLE: V CEDING FOUNDATIONS: _FT PROr.m _inns: 1,C) FT POTABLE WATER Ln'zis:Lji�y FT Ti SUBJECT TO FREQUENT EZOODING: [ ] YES [st/ NO 10 YEAR FLOODING? [ ] YES NO YEAR FLOOD ELEVATION FOR SITE: - FT MSL/NGVD SITE ELEVATION: FT'MSL/NGVD 1 ISDA SOIL SERIES:' TO TO USDA SOIL R`Fl4Ya�5- Y 1 1 �I.L nil�� • • TO ERVED WATER TABLE: 50_ INCHES [ABOVE / O EXISTING GRADE: Tim:[PERCHED / • ARENT T1omD-WET SEASON WATER TABLE ELEVATION: INCHES [ABOVE / LO .EXISTING GRADE H WATER TABLE VEGETATION: [ ] YES [ ] NO MOTTLING: [,�f YES [ ] NO DEPTH:94INCHES L TEXTURE/LOADING RATE FOR SYSTEM SIZING:DEPTH OF EXCAVATION: INCHES INFIELD CONFIGURATION: [ ] TRENCH 1A BED [ ] OTHER (S ECIM ARKS/ADDITIONAL CRITERIA: Vt/Q j V •'I'A I.P 1Z ■•_YR ME 101S, D8/09 (obsoletev Previous editions wbich may not be used) Ineotpmated: 64E6.007,FAC Page 3 of 4 0p 5t, STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATIONS PERMIT #. 1 ss4147 5 APPLICANT:RODOLFO VEGA AGENT:RODOLFO VEGA LOT: BLOCK: SUBDIVISION: PROPERTY ID # : 9/36/3409-411-0004-000-4 [ SectionlTownsh]p/Parcel No. or Tax ID Number TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [✓] YES [ ] NO NET USABLE AREA AVAILABLE: 2.285 ACRES TOTAL ESTIMATED SEWAGE FLOW: GALLONS PER DAY [RESIDENCES-TA13LE1/OTBER-TABLE2 ] AUTHORIZED SEWAGE FLOW: GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: SQFT UNOBSTRUCTED AREA REQUIRED: SQFT BENCHMARK/REFERENCE POINT LOCATION: SITE BENCHMARK ONE (SEE SURVEY) ELEVATION OF PROPOSED SYSTEM SITE IS1.5 [PT ] [ABOVE ] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: 75 FT DITCHES/SWALES:15 FT NORMALLY WET? [ ] YES [ ] NO WELLS: PUBLIC: 200 FT LIMITED USE:100 FT PRIVATE: 75 FT NON -POTABLE: 50 FT BUILDING FOUNDATIONS:5 FT PROPERTY LINES:10 FT POTABLE WATER LINES:10 FT SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [ ] NO 10 YEAR FLOODING? [ ] YES [ ] NO 10 YEAR FLOOD ELEVATION FOR SITE: FT MSL/NGVD SITE ELEVATION: FT MSL/NGVD TEXTURE DEPTH TO mo 1V TO TO TO TO USDA SOIL SERIES: A'V1L exyz'1LCi 1nzm�xiya "X& G MUNSELL #/COLOR TEXTURE USDA SOIL SERIES: DEPTH TO TO TO TO TO TO TO TO TO OBSERVED WATER TABLE: INCHES [ABOVE/BELOW 11 EXISTING GRADE. TYPE: I PERCHED /APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: INCHES [.ABOVE/BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ] YES [ ] NO MOTTLING: [ [ YES [ ] NO DEPTH: INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: DEPTH OF EXCAVATION DRAINFIELD CONFIGURATION: [ ] TRENCH [ ] BED ] OTHER (SPECIFY) REMARKS ADDITIONAL CRITERIA' SITE EVALUATED BY: 09/O8/2014 INCHES DH 4015, 12/11 (Obsoletes previous editions rhich may not be used) Incorporated: 64E-6.001,FAC Page 3 of 4 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRVCTION PERMIT CONSTRUCTION PERMIT FOR: OSTDS New APPLICANT: Rodolfa Vega and Carmen Hernandez PROPERTY ADDRESS: 904 Osceola Dr Fort Pierce, FL 34982 LOT: BLOCK: PROPERTY xD #: 3409-411-0004-000-4 SUBDMSION: PERMIT #:56-SF-1559475 APPLICATION #:AP1159393 DATE PAID: FEE PAID: RECEIPT #: DOCUMENT #: PR960454 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR 'ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 1.350 1 GALLONS / GPD Septic CAPACITY A [ ] GALLONS / GPD N/A CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ D [ 967 ] SQUARE FEET SYSTEM R [ ] SQUARE FEET N/A SYSTEM A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [X] MOUND [ ] I CONFIGURATION: [ ] TRENCH EX] BED [ ] N F LOCATION OF BENCHMARK: nail In washer In I ELEVATION OF PROPOSED SYSTEM SITE E BOTTOM OF DRAINFIELD TO BE L D E O T H E R [ 16.0011 INCHES FT ][ ABOVE BELOW] BENCHMARK/REFERENCE POINT [ 16.0011 INCHES FT ][ ABOVE P BELOW] BENCHMARK/REFERENCE POINT ai,i, „ Wuln w: L-lo.uul +Vuncc r;AUJv"X' un uYUiuU: L OO.uu J im.nac The system is sized for 5 bedrooms with a maximum occupancy of 10 persons (2 per bedroom), for a total estimated flow of 580 gpd. The licensed contractor installing the system is responsible for installing the minimum category of tank in accordance with s. 64E-6.013(3)(0, FAC. excavated material. SPECIFICATIONS BY: Ch tale Potts TITLE: Environmental Specialist II APPROVED BY: Sup 11 Victor Faconti DATE ISSUED: 09/15/2014 L , EXPIRATION DATE: DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC v 1.1.4 M1159393 SE938419 St. Lucie CHD 03/15/2016 Page 1 of 3 NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN # A02, Tallahassee, Florida 32399-1703. The Agency Clerk's facsimile number is 850-410-1448. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. DOCUMENT ft: PR950454 The bottom of the tank shall be opened or ruptured, or the entire tank collapsed so as to prevent the tank from retaining ter, and(c) The tank shall be filled with clean sand or other suitable material, and completely covered with soil.Have the stem inspected by the health department after it has been pumped and ruptured but before it is filled with sand and covered. must be abandoned in conjunction with new system installed to avoid reinspection fees STATE OF FLORIDA r DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: PERMIT NO. DATE PAID: FEE PAID: RECEIPT #: [✓] New System [ ] Existing System [ ] Holding Tank [ ] [ ] Repair [ ] Abandonment - [ ] Temporary [ ] APPLICANT: RODOLFO VEGA AND CARMEN HERNANDEZ AGENT: RODOLFO VEGA 14AILING ADDRESS: 712 NW GRENADA STREET, PORT ST. LUCIE, FLORIDA 34983 Innovative TELEPHONE: 772-240-3648 TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS 1 BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATI APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROPERTY INFORMATION LOT: BLOCK: SUBDIVISION: PROPERTY ID #: 3409-411-0004-000-4 PLATTED: ZONING: I/M OR EQUIVALENT: [ No ] PROPERTY SIZE: 2.285 ACRES WATER SUPPLY: [ ] PRIVATE PUBLIC [✓]<=2000GPD [ ]>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ No ] DISTANCE TO SEWER: FT PROPERTY ADDRESS: 904 OSCEOLA DRIVE, FORT PIERCE, FLORIDA 34982 DIRECTIONS TO PROPERTY: GO TO U.S. HIGHWAY NO. ONE TO MIDWAY ROAD AND GO WEST TO CITRUS AVE. AND GO SOUTH TO OSCEOLA DRIVE AND GO EAST TO THE END OF THE CUL-DE-SAC AND CONTINUE EAST ALONG A ROCK ROAD TO THE PROPERTY ON THE LEFT. BUILDING INFORMATION [✓] RESIDENTIAL [ ] COMMERCIAL Unit Type of No Establishment 1 SINGLE 2 3 4 No. of Building Commercial/Institutional System Design Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC 5 5071 [ ] Floor/Equipment Drains [ ] Other (Specify SIGNATURE: WNWITi `~W'. g„ f rt DATE: 09/08/2014 DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated 64E-6.001, PAC Page 1 of 4