Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RUDY & CARMINE VEGA Builder Name: Street: 904 OSCEOLA DRIVE Permit Office: � City, State, Zip: FT. PIERCE, FL, Permit Number: SCANNED v BY Owner: Design Location: FL, Fort Pierce Jurisdiction: St. Lucie County 1. New construction or erdsAng New (From Plans) 9. Wall Types (5736.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 5730.70 ft' b. N/A R= ft2 3. Number of units, If multiple family 1 c. WA R= ft2 4. Number of Bedrooms 5 d. WA R= f z 10. Ceiling Types (5086.0 sqft.) Insulation Area 5. Is this a worst case? No a. Cathedral/Single Assembly (Unvented) R=20.0 5086.00 ft2 6. Conditioned floor area above grade (ft2) 5086 b. WA R= ft2 Conditioned floor area below grade 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(905.0 sqft.) Description Area 2 additional duct system(s) 6 264 - a. U-Factor: Sgl, U=0.50 905.00 ft2 b. Sup: MASTER, Rat: MASTER, AH: MASTER 6 85 SHGC: SHGC=0.32 c. Sup: 2ND FLOOR, Ref 2ND FLOOR, AH:2ND FL (see details b. U-Factor. WA iN 12. Cooling systems kBbAr Efficiency SHGC: a. Central Unit 36.0 SEER:16.00 b. Central Unit 18.0 SEER:16.00 c. LLFactor: WA 2 additional cooling systems (see details) SHGC: 13. Heating systems kBtir/hr Efficiency d. U-Factor: WA ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 3.989 ft. 2 additional heating systems (see details) Area Weighted Average SHGC: 0.320 14. Hot water systems a. Propane Cap: 80 gallons 8. Floor Types (5086.0 sqft.) Insulation Area EF:0.590 a. Slab -On -Grade Edge Insulation R=0.0 5086.00 ft2 b. Conservation features b. WA R= ft None c. WA R= fI2 S. Credits CF. Pstat Glass/Floor Area: 0.178 Total Proposed Modified Loads: 68.41 PASS Total Standard Reference Loads: 86.95 I hereby certify that the plans and specifications covered by Review of the plans and STg7F this calculation are in compliance with the Florida Energy specifications covered by this O�•CtlE a 0 Code. calculation indicates compliance with the Florida Energy Code. •, •-% `"' • „ O PREPA BY' Before construction is completed "r'_' _ _ m DATE: this building will be inspected for compliance with Section 553.908 CA_ o_ y I hereby certify that this building, as designed, is in compliance Florida Statutes. rt' with the Flodda Energy Cod . COp yyETR OWNER/AGENT 7 x/ BUILDING OFFICIAL: DATE Eti //- - DATE: 828201410:52 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 PROJECT Title: RUDY & CARMINE VEGA Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 5086 Lot# Owner: Total Stories: 2 BlocklSubDlAsion: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 904 OSCEOLA DRIVE Permit Office: Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, NewlErdsting: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1932 18160.8 2 Block2 613 5762.2 3 Block3 1866 17540.4 4 Block4 675 6345 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MAIN 1932 18160.8 Yes 2 1 Yes Yes Yes 2 MASTER 613 5762.2 No 2 1 1 Yes Yes Yes 3 2ND FLOOR 1866 17540.4 No 2 3 1 Yes Yes Yes 4 GUEST HOUSE 675 6345 No 2 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MAIN 275 ft 0 1932 ft' — 0 0 1 2 Slab -On -Grade Edge Insulatio MASTER 95 ft 0 613 1`12 ____ 0 0 1 3 Slab -On -Grade Edge Insulatio 2ND FLOOR 267 ft 0 1866 ft2 ___ 0 0 1 4 Slab -On -Grade Edge Insulatio GUEST HOUSE 105 ft 0 675 fF ____ 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emift Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 5509 ft2 0 ft2 Medium 0.96 No 0.9 No 20 22.6 ATTIC / V # Type ventuatlon Vent Ratio(I in). Area. RBS, I.RG.G 1 Full attic Unvented 0 5086 ft2 N N 8/2812014 10:52 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 CathedraVSingle Assembly (Unvented) MAIN 20 1932 ft' 0.11 Wood 2 Cathedral/Single Assembly (Unvented)1ASTER 20 613 ft' 0.11 Wood _ 3 Cathedral/Single Assembly (UnventdMD FLOOR 20 1866 ft' 0.11 Wood 4 Cathedral/Single Assembly (UnveK1&4ST HOUSE 20 675 ft2 0.11 Wood WALLS Adjacent Cavity Width Sheathing Framing Solar Below. Spate _Height _ 1 N Exterior Concrete Block- Int Insul MAIN 4.09999 63 9 4 588.0 ft2 0 0.75 0 -2 E Extedor Concrete Block- Int Insul MAIN 4.09999 40 9 4 373.3 1`12 0 0.75 0 _ 3 S Extedor Concrete Block - Int Insul MAIN 4.09999 63 9 4 588.0 ft2 0 0.75 0 _ 4 W Extedor Concrete Block - Int Insul MAIN 4.09999 40 9 4 373.3 ft2 0 0.75 0 5 N Exterior Concrete Block - Int Insul MASTER 4.09999 16 9 4 149.3 ft2 0 0.75 0 _ 6 E Exterior Concrete Block - Int Insul MASTER 4.09999 40 9 4 373.3 ft2 0 0.75 0 -7 8 Exterior Concrete Block- Int Insul MASTER 4.09999 16 9 4 149.3 ft2 0 0.76 0 _ 8 W Exterior Concrete Block- Int Insul MASTER 4.09999 40 9 4 373.3 112 0 0.75 0 -9 N Exterior Concrete Block - Int Insu2ND FLOOR 4.09999 55 9 4 513.3 ft2 0 0.75 0 _ 10 E Exterior Concrete Block - Int Insu2ND FLOOR 4.09999 40 9 4 373.3 ft2 0 0.75 0 _ 11 S Exterior Concrete Block- Int Insu2ND FLOOR 4.09999 55 9 4 513.3112 0 0.75 0 _ 12 W Exterior Concrete Block - Int Insu2ND FLOOR 4.09999 40 9 4 373.3 ft2 0 0.75 0 _ 13 N Exterior Concrete Block- Int InsuGUEST HOU 4.09999 16 9 4 149.3 ft2 0 0.75 - 0 _ 14 E Exterior Concrete Block - Int InsiGUEST HOU 4.09999 37 9 4 345.3 1`12 0 0.75 0 _ 15 S Exterior Concrete Block- Int InsLGUEST HOU 4.09999 16 9 4 149.3 ft2 0 0.75 0 16_ W Exterior Concrete Block - Int InsuGUEST HO.U.4.09999_ 37 9. 4 345.3.ft2 0, 0.75- 0. WINDOWS Orientation shown is the entered, Proposed orientation. J Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Tinted) Yes 0.5 0.32 96.0 ft 10 It 0 in 6 ft 0 in Drapes/blinds None 2 N 1 Metal Single (tinted) Yes 0.5 0.32 18.0 ft2 2 ft 0 in 6 It 0 in Drapes/blinds None 3 N i Metal Single (Tinted) Yes 0.5 0.32 36.0 ft2 2 ft 0 in 6 It 0 in Drapesiblinds None _ 4 N 1 Metal Single (tinted) Yes 0.5 0:32 48.0 1`12 2 It 0 in 6 It 0 in Drapes/blinds None 5 N 1 Metal Single (Tinted) Yes 0.5 0.32 72.0 ft2 8 It 0 in 6 ft 0 in Drapes/blinds None 6 E 2 Metal Single (Tinted) Yes 0.5 0.32 24.0 1512 2-ft 0 in 6 ft 0 in Drapes/blinds None 7 S 3 Metal Single (Tinted) Yes 0.5 0.32 8.0 ft2 2 It 0 in 6 ft 0 in Drapes/blinds None 8 S 3 Metal Single (Tinted) Yes 0.5 0.32 30.0 112 2 ft 0 in 6 ft 0 in Drapes/blinds None 9 S 3 Metal Single (Tinted) Yes 0.5 0.32 48.0 ft2 2 It 0 in 6 ft0 in Drapesiblinds None 10 S 3 Metal Single (Tinted) Yes 0.5 0.32 18.0 ft2 2 ft 0 in 6 ft 0 in, Drapesiblinds None 11 W 4 Metal Single (Tinted) Yes 0.5 0.32 33.3 ft2 2 It 0 in 6 ft 0 in Drapestblinds None _ 12 N 5. Metal Single (Tinted). Yes 0.5. 0.32 48.0.fl2 2ft0.in. 6.ft0.in Drapesiblinds. None 13 S 7 Metal Single (Tinted) Yes 0.5 0.32 4.0 tN 2 ft 0 in 6 ft 0 in Drapesiblinds None _ 14 S 7 Metal Single (Tinted) Yes 0.5 0.32 24.0 1`12 2 ft 0 in 6 ft 0 In Drapesiblinds None _ 15 S 7 Metal Single (Tinted) Yes 0.5 0.32 6.0 fN 2 It 0 in 6 ft 0 in Drapes/blinds None 16 N 9 Metal Single (Tinted) Yes 0.5 0.32 45.0 ft' 2 ft 0 in 6 ft 0 in Drapes/blinds None 8/28/201410:52 AM EnergyGauge® USA- FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Ind Shade Screening _ 17 N 9 Metal Single (Tinted) Yes 0.5 0.32 100.0 ft' 8 It 0 in 6 ft 0 in Drapes/blinds None 18 N 9 Metal Single (Tinted) Yes 0.5 0.32 6.0 ft' 2 it 0 in 6 ft 0 in Drapes/blinds None _ 19 S 11 Metal Single (Tinted) Yes 0.5 0.32 16.0 tt' 2 ft 0 in 6 It 0 in Drapes/blinds None 20 S 11 Metal Single (Tinted) Yes 0.5 0.32 4.0 ft2 2 ft 0 in 6 ft 0 in Drapes/blinds None 21 S 11 Metal Single (Tinted) Yes 0.5 0.32 60.0 ft' 2 it 0 in 6 it 0 in Drapes/blinds None _ 22 S 11 Metal Single (Tinted) Yes 0.5 0.32 18.0 ft' 2 it 0 in 6 It 0 in Drapes/blinds None _ 23 E 14 Metal Single (Tinted) Yes 0.5 0.32 6.01F 2 It 0 in 6 It 0 in Drapes/blinds None 24 E 14 Metal Single (Tinted) Yes 0.5 0.32 40.0 ft' 2 it 0 in 6 It 0 in Drapes/blinds None 25 E 14 Metal Single (Tinted) Yes 0.5 0.32 26.7 fF 2 R 0 in 6 It 0 in Drapes/blinds None 26 E 14 Metal Single (Tinted) Yes 0.5 0.32 20.0 1112 2 It 0 in 6 it 0 in Drapes/blinds None 27 S 15 Metal Single (Tinted) Yes 0.5. 0.32 20.0 fN 2 ft 0 in 6 It 0 in Drapestblinds None 28 W '16 Metaf Singlb Finted) Y-'b 4.5 0.32- 30,4R' 2-11-0-Th 6iE13 in Diapeslbrimb None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 506 ft' 506112 40 It 9.4 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 6670.3 366.19 688.68 .4494 8.3713 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP: 1 27 kBtu/hr 1 sys#i 2 Electric Strip Heat None COP: 1 17 kBbilhr 2 sys#2 3 Electric Strip Heat None COP: 1 27 kBhAr 3 sys#3 4 Electric Strip Heab None COP3'1 17 kBWr- 4 iiM4 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts .1 Central Unit None SEER: 16 36 kBtulhr 1080 cfm 0.75 1 sys#1 2 CentralUnitNone, SEER..- 18 kBhVhr 540 cfm- 0.75 2. sys#2 3 Central Unit None SEER: 16 36 kBbAr 1080 cfm 0.75 3 sys#K3 4 Central Unit None SEER: 16 18 kBWMr 540 cfm 0.75 4 sys#4 8/28/2014 10:52 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane None Garage 0.59 80 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 MAIN 6 254 1`12 MAIN 20 ft' Default Leakage MAIN (Default). (Default) 1 1 2 MASTER 6 85 ft' MASTER 20 it' 'Default Leakage MASTER (Default) (Default). 2 2 3 2ND FLOOR 6 85 fF 2ND FLOOR 20 ft' Default Leakage 2ND FLOO (Default) (Default) 3 3 4 GUEST HOU 6 85 IF GUEST HOU 20 ft' Default Leakage GUEST HO (Default) (Default) 4 4 TEMPERATURES Programable Thermostat: Ceiling Fans:Coo Heating(��Y nting Jan Feb H Mar r I May [[�(]]. [[X]� Jul Junun [l Jj A g 4 ]j Sep [L ]1 Dec j) Pr l 1 Jun Jul 11 lxl Aug L l Sep lX) O Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 66 PM 68 68 68 68 68 68 68 68 68 68 66 66 828/2014 10:52 AM EnergyGauge® USA- FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS'.: 904OSCEOLA DRIVE PERMIT#: FT. PIERCE, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage reportor visually verify Table 402,4,2, Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing Cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRA€ 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4116/13). Heat pump pool heaters minimum. COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 8/28/2014 10:52 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 . Y 4 ' ti - � _ u _ `� _ _ �. _. _ _ .� - y _N ., - - is I n � � V ,_. � � i. � A _. _ _ r. - ' 1 r Cf _. w � M1 - _ a_ � _ - - '. - — - _ - i � � �� e- _ �. �. ' -- . t? 4 � _ i k — � �� _ _ ♦ ' � �� F _ l . ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ES MA ED ENERGY PERFORMANCE INDEX* _ The lower the EnergyPerformance Index, the more efficient the home. 904 OSCEOLA DRIVE, FT. PIERCE, FL, 1. New construction or eristing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int insul, 6derior R=4.1 5bbJb iP b. NIA R= fN 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 5 d. N/A R= ft' 5. Is this a worst case? No 10. Ceiling Types Insulation Area a. Cathedral/Single Assembly (Unvented) R=20.0 5086.00 ft' 6. Conditioned floor area (W) 5086 b. NIA R= ft' T. Windows" bescription Area c. N/A R= ft' a. U-Factor: Sgl, U=0.50 905.00 f 2 11 • Ducts 2 additional duct system(s) R ft' 6 254 SHGC: SHGC=0.32 b. Sup: MASTER, Ret: MASTER, AH: MASTER 6 85 b. U-Factor: WA fe c. Sup: 2ND FLOOR, Ret: 2ND FLOOR, AH: 2ND FL (see details SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft' a. Central Unit 36.0 SEER:16.00 SHGC: b. Central Unit 18.0 SEER:16.00 d. U-Factor; NIA ftx 2 additional cooling systems (see details) SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.989 ft. a. Electric Strip Heat b. Electric Strip Heat 27.0 COP:1.00 17.0 COP:1.00 Area Weighted Average SHGC: 0.320 2 additional heating systems (see details) 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 5086.00 fFEF: a. Propane Cap: 80 gallons b. NIA R= fF 0.59 c. N/A R= ft' b. Conservationfeatures. None 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code cginpliant.features. Builder Signature: _ Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software - wrightsoft° Project Summary Date: AHU 1 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone 772-46"799 Fax 772-4666796 snail: OUICKCALCS@AOL.COM Proiect Information For. RUDY & CARMINE VEGA 904 OSCEOLA DRIVE, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily-- nge L Relative humidity 50 % Moisture, difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 32964 Btuh Structure 26568 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (Q cfm) 0 Btuh Ci!MW vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32964 Btuh Use manufacturers data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25240 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2298 Btuh Ducts 2715 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (f:2) 1932 1932 Equipment latent load 5013 Btuh Volume (W) 22740 22740 Airchanges/hour 0.22 0.12 Equipment total load 30253 Btuh Equiv. AVF (cfm) 85 45 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM, RUUD, WEATHERKING Model Cond 14AJM36 AHRI ref Coil RHLL-HM3821++RCSL-H•3821 AHRI ref 3805983 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 9.7 kW Sensible cooling 25760 Btuh Heating output 33156 Btuh Latent cooling - 11040 Btuh Temperature rise 25 OF Total cooling 36800 Btuh Actual airflow 1227 cfm Actual airflow 1227 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsofY Universal 2014-Aug-28 10:52:53 RIghtSuOe® 201313.0.15 RSUD8101 Page 1 ACCK ...cuments\Wrightsoft HVAGTemplateTt. Pierce.mt Cale=MJ8 Front Door faces N -� wrightsofte Project Summary Date: AHU 2 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@POL.COM Pro-ect Information For. RUDY & CARMINE VEGA 904 OSCEOLA DRIVE, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 9884 Btuh Structure 10323 Btuh Ducts 2291 Btuh Ducts 1754 Btuh Central vent (0 cfm) 0 Btuh Central vent (AD oim) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12175 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 11474 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1174 Btuh Ducts 977 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 613 613 Equipment latent load 2150 Btuh Volume (W) 6034 6034 Air changes/hour 0.34 0.18 Equipment total load 13624 Btuh Equiv. AVF (cfm) 35 19 Req. total capacity at 0.70 SHR 1.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM, RUUD, WEATHERKING Model Cond 14AJM19 AHRI ref Coil RHLL-HM2417++RCSL-H'2417 AHRI ref 5550186 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 3.5 kW Sensible cooling 13090 Btuh Heating output 11975 Btuh Latent cooling - 5610 Btuh Temperature rise 17 OF Total cooling 18700 Btuh Actual airflow 623 cfm Actual airflow 623 cfm Air flow factor 0.051 cfm/Btuh Air flow factor 0.052 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wri htsofY 9 RigMSuae® Unimml 201313.0.15 RSU08101 2014-Aug-2810.52:53 Page 2 ...wmentsUrightsoft WAMTemplate\Ft. Pieroe.nE Calc = MJ8 Front Door faces: N Project Summa Job: - wrightsoft® AHU 3 ry By QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL34946 Phone: 772-466-6799 Fax n2-46M796 Email: OUIOCCALCS@AOL.COM Project• • For. RUDY & CARMINE VEGA 904 OSCEOLA DRIVE, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db. 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily -range L Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 20004 Btuh Structure 21643 Btuh Ducts 6342 Btuh Ducts 4833 Btuh Central vent (ID cfrn) 0 Btuh Central vent (fl dfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 26346 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25152 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1832 Btuh Ducts 2699 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (fta) 1866 1866 Equipment latent load 4531 Btuh Volume (W) 17531 17531 Air changes/hour 0.28 0.15 Equipment total load 29683 Btuh Equiv. AVF (cfm) 82 44 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade Model Cond 14AJM36 AHRI ref Coil RHLL-HM3821 AHRI ref 3805983 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.7 kW Sensible cooling 25760 Btuh Heating output 26442 Btuh Latent cooling - 11040 Btuh Temperature nse 20 OF Total cooling 36800 Btuh Actual air flow 1227 cfm Actual air flow 1227 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wri htsofY g RlghtSu@e® Universal 201313.0A5 RSU08101 2014-Aug-28 10:52:53 Page 3 AM ... wments\Wdghtwft WAC\Template\Ft. Plem .nR Calc= MJ8 Fmm Door faoev N -- wrightsoft° Project Summary Date: AHU 4 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Far 7724666796 Email: QUIO(Q1LCS@A0LC0M -Project• • For. RUDY & CARMINE VEGA 904 OSCEOLA DRIVE, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range Relative humidity L 50 Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14364 Btuh Structure 9534 Btuh Ducts 2368 Btuh Ducts 1811 Btuh Central vent (0 cfm) 0 Btuh C&Itrai veht (0 cfrn) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16731 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 10777 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1000 Btuh Ducts 1010 Btuh Heating Cooling Central vent (D cfm) 0 Btuh Area (ft2) 675 675 Equipment latent load 2010 Btuh Volume (ft3) 6392 6392 Air changes/hour 0.42 0.22 Equipment total load 12787 Btuh Equiv. AVF (cfm) 45 24 Req. total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM, RUUD, WEATHERKING Model Cond 14AJM19 AHRI ref Coil RHLL-HM2417++RCSL-H'2417 AHRI ref 5550186 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 4.8 kW Sensible cooling 13090 Btuh Heating output 16382 Btuh Latent cooling - 5610 Btuh Temperature Ase 24 OF Total cooling 18700 Btuh Actual airflow 623 cfm Actual airflow 623 cfm Airflowfactor 0.037 cfm/Btuh Air flow factor 0.055 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsofr r 9 RightSude® Universal 201313.0.15 RSU08101 2014-Aug-2810:52:53 Page 4 ... mments%Wrightwft WAC%Template%Ft. Pleme.M Calc= MJB Front Door faces N wrightsoft, AHU 1 ® Worksheet Job: Date: By: QUICK CALCS, INC. 317ST. LUCIE LN., FT. PIERCE, FL34946 Phone 772-466-6799 Fax 772-4666796 Email: QUIO(CALCS@AOLCOM 1 Room name AHU 1 LIVING ROOM 2 Erased wall 1924 Ift 24.0 ft_ 3 Room heigIT 11.8 ft d 20.0 ft _ _ heaticool 4 Room dimensions 24.0 x 18.0 ft 5 Room area 19320 ft- 432.0 W Ty Construction U-value Or HTM Area (ft) Load Area (ft-) Load number (Btu)Vft;°F) (BtuWft2) or perimeter (ft) (Btuh) or perimeter (k) (Btuh) He Cool Gross NIPIS Heat Cool Gross N/PIS Heat Cool 6 W 13A-0o. n 4.00255 451 42 1711 1080 0 0 0 0 1Aclorn m: 11.270270 n 0.00 0.00 0 0 0- 0 0 0 0 0 0 1.270 n 0.00 0.00 0 0 0 0 0. 0 0 '0 1Aclom- 1A 1.270 n 0 0 0 0 0 0- 0 0 11 IA-Morn3A 1.143 n 5.56 30.56. 5.39 20.00 24 0 853 633 0 .0 0 0 V)J 13A-4am na 0.00 0.00 0 0 0 0 0 0 0 0 1Ac1om 1.270 1.143 0 0 0 0 0 0 0 0 -C 13A-4acs. 0.143 o a 4.00 4.00 255 255 395 291 1164 740 0 0 0 0 10A-m 1.670 a 0.00 0.00 0 0 0 0 0 0' 0 0 10A m 1.670 a 46.76 53.19 48 10 2244 2553 0 0 0 0 1Aclom 1.270 a 0.00 0.00 0 0 0 0 0 ' '0 0 0 1Aclonn 1.270' a 0.00 0.00 0 0 0 0 0 0 0 0 1Ac1om 1.270 a 35.56 91.12 8 0 294 729 0 0 0 0 1A,clom 1270 a 0.00 0.00 0 0 -0 0 0- 0 0 0 1Aclom 1.270 a 35.56 91.12 30 0 1067 2734 0 0 0 0 1Aclom 1.270 a 35.56 91.12 18 0 640 1640 0 0 0 0 13A s 255 335 335 1643 0 0 0 0 IFLF-------GGGG 1AA rn 1.670 1.270 s 6.76 40.00 20.0 35 35 1643 889 880 0 0 0 0 I 1Actom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1Ac1om 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 1Ac1om 1. s .00 0 0 0 0 0 0 0 0 W L-G 13A4dcs 0.143143 sw 4 4.00 255 Z55 40 22 90 57 0 0 0 0 1Ac1am. 1.270 sw 35.56 27.28 18 0 622 477 0 0 0 0 13A-4ocs 0.143 w 4.00 2.55 790 538 2155 1370 480 360 1441 916 10A-m 1.670 w 46.76 53.19 48 0 2244 2553 24 0 1122 1276 1Actom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1Aclom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1Aclom 1.270 w 35.58 3223 36 0 12BO 1160 0 0 0 0 1Aclomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1Aclomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A- Iomd 1.270 w 35.56 28.38 72 0 2560 2043 0 0 0 0 1A-Momd 1.270 w 35.56 28.38 96 0 3414 2725 96 0 3414 2725 1�J 13A-4ocs. 0.143 rrw 4.00 2.55 40 22 90 57 0 0 - 0 0 L~1C' 1Aclom 1.270 w0.00 0.00 0 0 0. 0 0 0 0 0 1Actom 1.270 nw - 35.56 28.76 18 0 622 46B 0 ,. 0 0 0 P 12C-0sw 0.091 - 255 1.28 338 338 862 434 0 0 0 0 C 16X19-19md 0.049 - 0.79 0.74 289 289 227 213 36 36 28 27 F 19C-19cecp 0.049 - 0.00 0.00 0 0 0 0 0 0 0 0 F 22A-tpl- 0.9B9 - 27.69 0.00 1932 192 5328 0 432 24 665 0 F 22A-td 0.989 - 0.00 0.00 0 0 0 0 0 _ 0 0 0 6 c) AE D ercursicn 0 572 Envelope lossrgain 30354 23360 6670 6516 12 a) Infiltration 2SD9 749 6(Y7 174 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 480 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 32964 26568 7277 5690 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 32964 25568 7277 5690 15 Duct loads p% 0% 0 0 0% 00/ 0 0 Total room load 1 32964 26568 7277 5690 Alr required (cfm) 1227 1227 Z71 263 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wri htsoft' 2014-Aug-2810:52:53 A 9 Rlghte)Fte®Uoo.rut31 Cale= .8 rent Door Pagel ...wmentslWrigMsoft FiVACITemplatelFt. Pierce.M Calc= MJe Fmnt Won faces: N WF Y L cn go 00 a O O O aO a yNj N N N $ U _ 91 00000000:$0000000000000000000000000000 o 8 m0 v 000 0 �v�yy8 — �+ i3 oi x o o O o O O O�g O O O O O o o 0 O O o o O o o o o o o O o o O O o o o o o o O o- O � N ° o v 00 0o0o0om80oa00o0o00000000000000000000000@0 o o 0000000-0000oo0g00000O0000o0o0000000NOOO N �lbb Qi 1 y K �0 0o v„Z E6 000Eo E�6 p Ef U a= 0000000 9.0000000g0000 o'MM00000000000000o�o�yo aLL yt BS qo � 000�ogs 0 E ,. m m = NNi x 000000080000000000000000000000000000m0No o N £ m n x!� v o ".E 000000000000000m00000000000000000000mo80 o o � �'R888Sf887R8r'88�8��1P.i•�888YiR�43°'88R88R°�+3'i$SnR�888 — � Nooc ooN0 '0O 06EN OOON N o0 00 oio moo o o' - R �i, si m R cri 8 i%) RR �i ,.. '8'.888�i8888nSS�iPi,S��Sngggg�8n88888�i888 �i ��8�g _� -- E do0o 8'oqq dgqvo�oov0 o,u�8v�000v8d�oo�cc v�'�dov�'NcorN c, {{0@ �p O CCLCCpp.000000000NNNNN E, 333333333, 'E " " opp pppppp pp 0pppp0gg0pppp pppp000 0o00000000 app o� gp Nk�Nkyok�o i�o 4o k�Fi.F I�i,N NoioN Fi, iviV�cAi.������a�ho���Ef �� ?� $O 0 0 � _ yj EEEE E$� ;E'EEEEE EEE ,r EEEE EEE y; EE bpop oC ob,,EEy} Eyy0000 b� 0000a Soo 9� V�¢d¢d YYYdr7�¢¢¢d¢ $ E''SE@ U pop popo ,,EE7}.00 pop s,EEy 7¢¢de�4 dQQ��¢ Q ¢QYvo�� E MO $ EE E E E E 8 wK Rg �v d d cj Y z 2V J O a U ryryU V Z Im G o.000000000000000000000080000o00000000000.. ao o00�O ;=8 _ 8 U a� Iz Ro 11"" �m o0000000000000000000000�00000000000000-0 BS 000§0 ?f §;= �S z m w = 0 U O! K v' O O O O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 v O' Q 0 5 m o L v o of d E � 0000000000000000000000OROOOOOOOOOOOOOOAeo N Fi mm Q `o U 0o00o0 000000 O OOOOOOOOOo0o00O0000 000 mo 00 m_ 00000 WE - 8 O L 0o0oo0§000 0009ON000O00000000000000OHogo �S I wo p� Ooopo p�, kop'� o $ � r x n.o 00000900OOo000HO00000O00000000oocoRono .e v oo E POOOOOOROO 000080pf0000000000000000000%0&10 0 H3HHHB3HHi'RH''HH�H��`S3mHHHi'R�'�ir'H8F3HHg3°�S�u3Hn�nHHH g N0000 oN 000�ommNoo oN �Nocoo��Nc �.=o 000' U 8'68HRHHHHt°HHfRHfRfRHmHHHHY3Hn8$538HFRR$H53�3RH�8' i ooc�goov c.4ccAo�j,'wg'vma'od o v 8vwoo�go o�g�gv c�g No dnid �� � ccccc$$m.m m mm mm mm wwwmwu3iu;33333333E€������ LL O O O O O O O O O O O O O O O O O O O O O �3i' O� C EEEE YYYiSooEoEoEE.EEE E�EEE'EAl 0000,0YYYYYY YE o fE Vo EEQE QEEE¢E¢EEQ ¢aEll_@ ¢¢��¢¢¢QQ g EEE w I�Rg� O � zo' w630 ra F [I�f.I�(If >(IIJ > 5�. 2U LLLLLL mn 63 p m ttI z l0 8 m mA WIN+ gg 9 yC, )Cy, oNNN 5y, �» _ Pv TTT O'O I TIL IIL IrL 88E A dyy Ab3hb3g A�a Y33a3 'o'h 333 - 33hihAA 3333333' 3 s Ma iO c ���oeo��000000e0000000�o e� N (�J (� (�f ((�� y (� ((�� p O V O O.N W O A W m O O 010 O d A V' A o 0 0� A m e 0 N 0 Om O A O O S O O O A x w [.� 75 Hffi$��i �iHHai �iH H�HHmH�'i Hg HHoi H�'i x'i 8`d'iH Hm$HH$ifiHHHH �2 0 Tcy S3 000PNVogOMP o,l°%OOii Op 000fTi t20f2p4o(Nn ootNJ000(Nn g (N2 H HHAW tVTS(Ii IaHH HEIH H(O �i�tnHHH+�[11N NHNHHlO Ht11SH(OHHStII W O D O- p A(J O H O �m O o 0 0 0 0 H O 0 0 NIIm O O O O O V O O O O O O O O O O O O O O O J �'� G A Z 33 x x I� OO IIJJ ((JJ ttJJ OQiO WOOONOOOOo000100 N0000 AIO OO000000000000V 9 W 3 0 INJ x 0 x0 � 8 .o l C B iQ$ t32 _02000 2100 08 o �j OS 1O O O N O O O O O O O O O O H V O O O O O O O O O O o 0 0 0 0 0 0 0 0 0 0 G) 0 ll W O V J o m O OV o O O O N o o o o o>+ 0 0 0 O O O O O O O O O O O O O O O A O O O§ 'E 0£Soo`v00000000000in000000000000000000coo oA I xa 0 '9 8 y� 5� [�y+ {� 2 m O p o� � o9Ooo ol"S A o00o§000O8000oof380oo0000000060000000... �a x� o - o7lSo oo 2K 00 oiu 1'. YS ooOoGiOOOoS+o 0000m�n oo oo00000000000000GS000� L� G 3. M 0 4 T NA WINS �n TTT CIT IrTI T���.T� Ir 8331Yt832 �� 8 o o �j pC�Gy�G�Ly�Lp�pppC p� Abi�AAAd�A A b_b�h_d_Abb_bg d��AA 'o �if� o 4'9."P o 0 000 0000 0 ooa o 00 00 0� o oo 00 i-p' 3.3 a 3a3333 333, 33333.3', 3 3:3a33 'm a6 0 J $o ss �c ro �'# o Y6%tn%�oo �io�ododoo �i o�ioo�o �i7 d000000 �io�i0000 �i �0 `..O ��"�����FFFFFF£££`�`�Nmmmmmmmmm o'mmm00 J'J JJJ �� O8VPaO0N8p>Pilil 00(J 00>>,AffJJ 00p t� �?PN 000a 0A OOffJJ OO _ 8zdEAfi8869 88@88al8F8888$S@8988288889888O8A Qom' N 00oP.- ON� oo,�i3'oo Po NNoo O,cyiN��omo O,Eao I.W O O O O O N E3 888A� M8 a E8 p 8 8 N 8 8 8 a ua888sfANN8N8888988E8888a G) oy 1^a o o& o& o o o o o o o o o o o o o o o o o o 8 zoo o o o o o o o o o o o o o o� o a g n oOlO L Ofo0oo0000000000o00omEPo 0000000o00oob OfJll � W l m G i4+D K AJ 0o0 S o8 K o�090000000c00000oo000��000000000000000� x PD n 8 2S — A000 V OO OE$ yy in pp _ O00EBOo0Oo00o0000000000940000000000000002 G7 0 0 o$ot000000000000g60000mNo00o00000000000.z g'� a a p .. n q 'O N NO b1000000000000tA000000)MOOOOOOOOOOOOOOO NL 9 3 0 ON NQ K i0 A x 89 A OOO 9 0 Ni 0260E0 0oo00000000�00000§�000000000000000� mt m J fJ0 OiS000 O 00 O(Jll (11 Ol ((�� 0008000000000000A0o 000 NV 000000. 00000000-+ 7 A n� C D C A 0 C CO) 0 2 y n 3 CD C O m 4 O t O1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O co 0010 00000 00 U mx m9 00o00000000000000o0000000000000000000000 0 00 0 00000 00 0 N ui = Z'. x x �O x 0000000000000000000000000000000000000000 o N S m i v o m � .� 8 w 00000000000000000000000000000000000oo0Q0 0 @w N 0 0 0 0 0 0� 0 0 0 0 pO 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 �D �1 1` O 00 O O O O U 8000000�0000y00000000000000000000o0§0 0�O F3 cS 2� 80 {� N 000V N� Qy� N > � � x z o! K O pji 3 x 0 0 0 O O O O ONI O O O O O O O O O O O O O O O O O O O O O O O O O O O` O O N O o y +LL a 0 C6 n g w 000000080000m0000000000000000000000'oO�;0 o `R888R'00N0r'88�896'iR nH0-01NYSi`H.°-'8SgddN20Ndno 8ddd8 g N000�ooNo�d6mommN�000N nN N�oo�Yod��No��o o'o c' x N ggS$'�i88g$n8s �ig��igr"gg8 g, �igngg �iS $�'�88�'��8�8:. -- � v000�ooaoc�'o cu�'o��6m�'ooc ou�'v maio6�do�v;'�6o �u;'Noor�o, • ccccc$�.m mmm mmmmmwmwwwy333333333€��� LL AO^o g^O ^O^ nOn nOn nOn hOh O O O O nnO o^o^ ^O^ O nnO O AOA o^o^ o^o^ mm qm O'NN N �O O N N N N N O O N O� N N N N O I: I: csci cidd 0 OX o y� y� y� y� ,� 2S0000 E Edo-o Er Ed B€oo Efi o 00000 'boo ems ,g c D Y v ip U YYY V v44 ppYYY sFEy 444444 pp.4 �qq YYY Y99V V yyEE VVVYY4 rr YY 0ED 1 � mg EE .a c �I bA EEE .¢¢d aa�dd¢G¢¢¢IT, c8i�m m �- i_'&' E� 8 ax H zgg�T�jmg A¢vio a 5 aUuuu mn' �N�CIY�m 0 v WA WAN+ gg _ Ln TTT09Ir-Irk Ir�Ir�I-Ir�I-� r�ImI I-'Ir�m �i 8 o $4 ° o GiL7 7�G7 L7 L�G�L� L1 G�Gf G�L� 338; 3 g 3/N,AA NDa ppDpp--- D ---- ------ �,]jA AAAAi' b AAAi'AAjjjAYyAA AA� o -3rvfa mm�°�of� o. 0 n m.mF 0 at'- P £i o 0 0 0 3 33 3 33 $ o 0 000' o 000 0 0 0000 o.$7r �m o'o 3.3�3a a333 3 ,333333333 f�.3 �3a33, ,3o 0�, � W y o �_3 j/ �poop 8o 8o OoO�+pp+++++��pv�pv��po_, yoy ����yOy��NJJN+tJ��J.II�+�+yoy+pp+���yo ' fO tO tOtO+�OW000OOO�OW�W��OOfJO0000000fJ 0(J000OfJ xAC TO 10 ��������FFFFFFFFFf Fmmmmmmammmmmm m'��» » > � OVOO.N NO AN WOO(1�OOWAA OOOmIAO(1�OON0 A00W000A ^ {.� 75 $ffi$ie Fn'�'igg�i�'88�'i88m8iR$$$$m8�}ii8 �i88m8888 �i88, 88 �x 0000�-NoN�RNOo�3',00PN:,�N000,EiiN��otOooPo NooN000N B_ 888A�aiA88 888E2888ma888!2RNN8N88m8R888888a G) am m o 0&00 0000000000000000000m000000000000000o m ��^ 0 a 9 W _ x c O N O O O O O O O O O O O O O O O O O O O O Of0 O O O O O O O O O O O O O O O O iN X O�x (� OlA OT000 AT OA W + V 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N m O .. S_ NV 0�3000 t co 0� 8 0000000000000000000000o$0000000000000000 G OF N q Z Ra l 9 N S 6 8 e.1 cm t," 49 Of u 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5 0 0§ 0 0 0 o 0 0 0 0� 0 0 0 0 0 0 0 Q 0 0 0 ASS WW (`1 R O O O O OfQ S- L x O �O 9 m O O O O O O O O O O O O O O O O$ O O O O O n O O O O O O O O O O O O Y O< O tb Y n N m N O !,yQ( O O O $ N 6� tom o! K W O.O O O O O O O O O O O O O O O O O o o Oro wo O O O O O O O O O O o� o� O N h O v w N 5` Or Z O O NC '0 0 0 0 O O O O O O O O O O O O!z o o v O O O 8 O O O O W O O O O O O O E O E O N cs ago � v„Z 000000mooy00000gOA9000 §0000vOOOOOOOMOoo M c'"i bi iG y2o o 000 rzo 8 U a a� 9 t «m V 0 0 0 0 0 9 0 0' 0 0 0 0 0 O N R O O O& 0 0 0 O 6 O o o o o oo m o 77SS � ��NN ii 8�w5( a �Oi CN,�000000t&OOOOOOOO�OfDN00'D t9000000000000W0t$O .� a_ 0 0 Cd co .E 000000�o ov00000y00 NOOO800OO�oO00000momO - 7ii ry N R `53888888Si88�88888f 8 dggd6d"dd88�8888888n88$ N000000Noomod000Nocj'.cj'000Notiocococ00000c o 8888888888s8.8.888888888SR888 = � -- = voti0000 eo ov�0000c6o�t�'c oo vctiocv�'ootioc c� oonN ti, � rcccm$$mm mm m m'mmmmmmmm��333333333€.€������ �� oO O 000O o0 0000 o Oo0 0 0 m aq OQ o c n c ao � 'E'EE E� E.EEEEE� EEE�{'E EEEEE�E EFL 0 ao 000¢a H, 0 ffls, o °U c '� to $ aE Ti E�gEE U ppo gqmao yE qo p0 p0 ,,EE}}pop goqoo %dQ¢ � cid aQQ���Q¢ Q 3ddQ¢ tg-R, E g °E Ems' $ E� oo �N�m vm m to d w p R T � 0 (L a� Of 'L In PO00000�00900000QOAO000000000000OOOONOOo. ''f�rjj PP. Or tQ '!o p0 OO OtQ .m'.' �� ��`jj IV O qN� O O O O O O �j O O N O O O O O bM0 M O O O O O O O O O O O O O O O O O$ O O � � � f0 O 00 O- N S 0 0 0 0 0 0 8 0 0 O.O O 0 0.0 P 0 0 0 O O O O O O O o 0 0 O 0 O 0 0 0 A 0 8 O S' xm Z a 0 ".� M00000ovoov00000@om0000000000000000OA0yo 0 R ai � S. m N e o O O O O O O O o 0 0 0 0 0 0 o 0 0 0 0 0 0 O'O 0 0 0 0 0 0 0 0 00 0 0 0[-, 0 0 0 8 o o do R O O O ql O N Q r'0 J� O O O O O O O O O O O O O O O O O O O O O O O O O O O O O o o O O O O O R O O O a 00 8 O O O 0 h (V 8 N m 1p N �.! = Uo X � 000000000000000000000000000000000000�8000 � o N n � ro E Z V O m fg v C O O O O O o O O O 000000000000 O O O O O O O O O O O O O O 0 8 0 s O O e {�1 l �3888888Y388Y88888Y38X�888c38888�8888888o888 8 Nd6d6d6Nodm00000NoX4,000N0000m00000000co o' �y� U 2 ggggggBggS�ggg88Sg��g 888g8gg �igggg8gg�g�g g �- = 6000000voo�00000do��000dooddv�'0000cocecrNc ' 0 cc ccc$$a as a as a a 000000Ne333333333€€€����� LL O O O QQOOIO^�AOA tO� Q^Q^ AO IOn�IOn�[� on O[a^�OIO�OOOO OOrq d N��FI6N.cj 1O � kVcj(V d� v^iVNN v N N N 1: tV 1: 1:1:C o���.=ono:=.=���..=d.=o�.=.=moo.=o.=.=.=1��.=.=o0000 o �. U o _� C oE 0$sE0.30!EE bEEEEF EEEEyVE¢oEY '0 E �d' " i `uo g' _mE Uc E ¢oVoYo¢oFa �a,YYY ppqq ,% �¢V¢VY¢Y E E EEE ¢ rc¢a913 �� c� aUuuu u ma J, av wrightsoft° gh - ® Worksheet Job: H Date: By: QUICK CALCS, INC. 317 ST. LUGE LN., FT. PIERCE, FL34946 Phone 772-4668799 Fax 772-4666796 Emaff: QUIOCCALCS@AOLCOM 1 Room mme WIC TLT. 2 E)posed wall. 8;0 ft 10;0 ft 3 Room helght 9.4 ft heat/cool 9.4 it heat/cool 4 5 Room dimensions Room area 6.0 x 8.0 ft 48.0 ft' 4.0 x 6.0 ft 24.0 ft- Ty Construction U-value Or HTM Area OF) Load Area Load number (Btuh/ft-F) (BtUMV) or perimeter (ft) (Btuh) or pedmeer (ft) (Btuh) Halt Cool Gress WP/S Heat Cool Gnzu NIP/S Heat Cool 6 13A-4o 0.143 n, .00 255 0 0 - 0 0 0 0 0' 0 1Aciom 1.270 n 0 0.00 0.00 0 0 0 0 0 . 0 0 0 1Aclom 9.270 n 0.00 0.00 0 0 0 0' 0 0 0 0 1A-M omd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 '0 11 13A ore 1.143 h OAO' 0.00 0 0 0 0. 0 0 0 0 1rN L--G 13A-4ocs ne 0.00 0.00 0 0 0 0 0 0 0 0 1Aciom 1.270 1.270 .00 0 0 0 0 0 0 0 13A�4ocs 0143 a a 4.00 255 255 0 0 0 0 38 38 151 96 10At 1.670 a. 0.00 0.00 0 0 0 0 0 '0 '0 0 1OA-m 1.670 a ROD 0.00 0 0 0 0 0 0. 0 0 1Ac1am 1.270 a 35.55 91.12 0 0 0 0 0 0 0 0 1Aciom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1Aclom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1Actom 1.270 a ROO 0.00 0 0 0 0 0 0 0 0 1Aclom 1.270 a Q00- 0.00 0 0 0 0 0 0 0 0 1Actor i 1.270 a 0.00 0.00 _ 0 0 0 0 0 0 0 0 0.143 s 4.00 2.55 75 75 301 191 56 48 194 123 10A-m 1.670 s Q00 0.00 0 0 0 0 0 0 0 0 N13A-4ocs 1Actom 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 1Actom 1.270 s 35.58 34.77 0 0 0 0 8 8 234 278 1A<1om 1270 s ROD 0.00 0 0 0 0 0 0 0 0 @/ 13A4ocs 0.143 sw 0.00 0.00 0 0 0 0 0' 0 0 0 �G 1Aclom _ 1.270 sw ROD 0.00 0 0 0 0 0 0 0 0 13AAocs 0.143 w 4.00 Z55 0 0 0 0 0 0 0 0 10A-m 1.670 w ROD 0.00 0 0 0 0 0 0 0 0 1Aclom 1.270 w ROD 0.00 0 0 0 0 0 0 0 0 1Actom 1.270 w ROD 0.00 0 0 0 0 0 0 0 0 1Aclom 1.270 w ROD 0.00 0 0 0 0 0 0 0 0 1Aclomd 1.270 w 35.58 91.12 0 0 0 0 0 0 0 0 1Aclomd 1270 w 0.00 0.00 0 0 0 0 0 0 0 0 1A-riomd 1270 w Q00 0.00 0 0 0 0 0 0 0 0 IA-Momd 1.270 w 0,00 0.00 0 0 0 0 0 0 0 0 Wi 1aA-4ocs 0.143 m 0.00 0.00 _ 0 0 0 0 0 0 0 0 IF 1Aclom 1.270 my oA0 0.00 0 0 0 0 0 0 0 0 1Actom 1.270 my DAD 0.00 0 0 0 0 0 0 0 0 --GC P 12C-0sw 0.091 - 0.00 0.00 0 0 0 0 0 0 0 0 C. 16XI9-19md 0-049 - 0,79 0.74 ,. 48 48 38 35 24 24 19 18 F 19C49oscp 0.049 - (100 0.00 0 0 0 0 0 0 0 0 F 27A-tpl 0.989 - 27.69 , 0.00 48 8 222 0 24 10 277 0 F 22A-td 0.989 - ROD 0.00 0 0 0 0 0 0 0 0 6 c) AED elcursion -11 44 Fsvelope loss/gain 560 216 925 558 12 a) Infiltration 95 27 119 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliarxes/other 0 0 Subtotal (lines 6 to 13) 655 243 1043 593 Less a#emal bad 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 655 243 1043 593 15 Duct loads 23% 17% 152 41 23% 17% 242 101 Total mom load 807 235 1285 693 Air required (cfm) 41 15 86 38 2014-Aug-28 10.52:53 Page 10 - -Ft&- wrightsoft^ RightSulteW Universal 2013 13.0.15 RSU08101 ...cumenls%Wdghtsoft WAMTemplate\Ft. Plerm.rut Calc = MJ8 Front Door faces: N �+ wrightsoft• Righ - ® Worksheet Job: Date: RFI By: QUICK CALCS, INC. 317 ST. LUCIE LK, FT. PIERCE, FL34946 Phone 772-4666799 Fax 7724666796 Email: OUICKCALCS@AOLCOM oom rents AHU 3 LOFT ErQosed2120 1t 19,0 (tRoom fRoarn height9.4 ft d 9.4 ft heat/cool dimensions 1.0 x 378.0 ft Room area 1865.0 ft' 378.0 fP Ty Construction U-value Or HTM Area (ft°) Load Area (ft2) Load number I (Btuh/ft'-°F) (Btutvft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross WP/S Heat Cool Gmss N/P/S Heat Cool 6 0.143 n 4.00' 2.55 376 376 1506 957 38 38 151 96 1Aclom 1.270 n 0.00 0.00 0 0 0 0 0 '0 0 0 %13A-4ocs 1Aclom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 1Actomd 1.270 n 0.00 0.00 0 0. 0 0 0 0 0 0 1A-r1om 1.270 n 0.00: 0.00 0 0 0 0 0 0 0 0 N! 13A-0xs 0A43 ne 0.00 0.00 0 0 0 0 0 0 0 0 1Aclom 1.270 ne 0.00 0.00 0 0 0 0 0 0 0 0 135-4bcs 0.143 a 4.00 255 620 542 . 2172 1381 19 19 75 48 10A-m 1.670 a OAO 0.00 0 0 0 0 0 0 0 0 10Ay 1.670 a -. 0.00 0.00 0 0 0 0 0 0 0 10 1A-clom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1Aclom 1.270 a '3556- 91.12 6 0. 213 547. 0 0, 0 0 1Aclom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 tAclom 1.270 a 35.56 91.12 24 0 853 2187 0 0 0 0 1Aclom 1.270 a 35.56 91.12 30 0 1067 2734 0 0 0 0 1Aclonn .. 1.270 e : 35.56 91.12 18 0 - 640 1640 0 0 0 0 1�J 13AA-m a 4.00 255 376 376 150 95 0 0 0 0 10A.670 1.143 a .00 0.00 0 0 0 0 0 0 0 0 0 0 1Aclom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 III 1Aclom 1.270 s 000 0.00 0 0 0 0 0 0 0 0 L--------GGGG 1Ao1om 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 W L-G 13A4xs 0.143 sw 000 0.00 0 0 0 0 0 0 0 0 1Ac1om 1.270 sw 0.00 0.00 0 0 0 0 0 0 0 0 13AAocs 0.143 w 4.00 255 620 467 1871 1190 122 88 353 225 10A-m 1.670 w 0.00 Roo 0 0 0 0 0 0 0 0 1Aclom 1.270 w 35.56 91.12 6 0 213 547 0 0 0 0 1Aclom 1.270 w 35.58 91.12 45 0 1600 4100 0 0 0 0 1A-clom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1Aclomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1Aclomd 1.270 w 35.56 3223 102 0 3627 3288 34 0 1209 1096 1A,r1omd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1Artomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 l�J 13AAocs Q143 nw 0.00 0.00 0 0 0 0 0 0 0 0 IL----fGi 1Aclom 1.270 rive 0.00 0.00 0 0 0 0 0 0- 0 0 1Aclom. 1.270 nw 0.00 0.00 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 - 0.00 0.00 _ 0 0 0 0 0 0 0 0 'C 16X19-19md 0.049 - 0.79 0.74 1865 1865 1466 1374 378 378 297 279 F 19C-19cscP - 0.049 - 0.48 0.25 74 74 35 19 25 25 12 6 F 27A-tp1 0.989 - CM 0.00 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 27.E a00 148 25 714 0 0 0 0 0 6 c)AED excursion 0 121 Envelope loss/gain 17484 20M 2097 1870 12 a) Infiltration 2520 723 226 65 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 20D04 21643 2323 1934 Lass external bad 0 0 0 0 Lose transfer0 0 0 0 Redsfdburfion 0 0 J26 0 0 14 Subtotal 20004 21643 23M 1934 15 Duct loads 32% 2296 6342 4833 22% 736 432 Total room load 26346 26478 1 3059 1 2366 Air reconed(cfm) 1227 1227 142 110 Calculations approved byACCAto meet all rE "& -Fk' wrightsoft' RlghtSuite® Universal 201313.0.15 RSU08101 ... moments\Wdghtmft FNAC\Template\Ft. Pierce.M Calc= MJ8 Fmnt DoorfamW N 2014-Aug-28 10:52:53 Page 11 wrightsofC nigh - ® Worksheet Job: H Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-4666799 Fax 7724666796 Email: OUIOCOaLCS@AOLCOM 1 Roomreme STAIRWAY BEDROOM 2 2 Dosed wall 30;0 ft 320 ft 3 Room height 9.4 ft heat/cool 9.4 ft heal1cool 4 Room dimensions 21.0 x 9.0 ft 14.0 x 17.0 ft 5 Room area 189.0 ft' 238.0 W Ty Cotstnx:tion U-value Or HTM Area (ft') Load Area (ft2) Load number (Btuh/fF-F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gass N/PIS Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs Q143 n 4.00 2.55 0 0 0 0 56 56 228 144 IAclom 1.270 n 0.00 0.00 0 0 0 0 -0 0 0 - 0 1Aclom 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 IAclomd 1.270 n 0.00 0.00 0 0 0 0 0 0 0 0 11 1A-r1orn 1.270 n 0.00 0.00 0 0 0 0. 0 0 0 0 YN 13A-4ocs 0.143 ne 0.00 0.00 0 0 0 0 0 0 0 0 1A lom 1.270 no 0.00 0.00 0_ 0 0 0 0 0 0 0 13A4ocs 0.143 a 4.00 255 197 155 622 396 132 102 407 259 10A-m 1.670 a 0.00 0.00 0 0 0 0 0 0 0 0 10A- m 1.670 a 0.00 0.00 0 0 0 0 0 0 0 0 1Aclom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1Aciom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 1Aclom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 1Aclom 1.270 a 35.56 91.12 24 0 853 2187. 0 0 0 0 1Aclom 1.270 a 35.58 91.12 0 0 0 0 30 0 1067 2734 1Aclom 1.270 a 35.56 91.12 18 0 .640 1640 0 0 0. 0 V)/ 10A,m s 4.00 255 255 85 85 330 215 113 113 450 200 t0A-m 1.143 1.670 6 0.00 0 0 0 0 0 0 0 0 1Ac1om 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 I�jF--------GGGG 1Aclom 1.270 s 0.00 0.00 0 0 0 0 0 0 0 0 `IAolom 1.270 a 0.00 (100 0 0 0 0 0 0 0 0 IITf 13A-4ocs aw sw 0.00 0.00 0 0 0 0 0 0 0 0 -G 1Aolom 1270'sw 0.00 U0 0 0 0 0 0 0 0 0 13A4ocs 0.143 w 4.00 255 0 0 0 0 0 0 0 0 10Atn. 1.670 w 0.00 0.00 0 0 0 0 0 0 0 0 1Aclom 1.270 w 35.58 91.12 0 0 0 0 0 0 0 0 1Aclom 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 1Aclom 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1Aclomd 1.270 w 0.00 0.00 0 0 0 0 0 0 0 0 1Actomd 1.270 w 35.55 3223 0 0 0 0 0 0 0 0 1A-rlond 1.770 w 0.00 0.00 0 0 0 0 0 0 0 0 1A7rlomd 1.270 w 000 0.00 0 0 0 0 0 0 0 0 13A4ccs 0.143 nw 0.00 0.00 0 0 0 0 0 0 0 0 1Aclom 1270 = 0.00 0.00 0 0 0 0 0 0 0 0 IAclom 1.270 nw 0.00 0,00 0 0 0 0 0 0 0 0 P 12C-D w 0.091 - 0.00 0.00 0 0 0 0 0 0 0 0 C 16X19-.19md 0.049 - 0.79 0.74 _ 189 189 149 139 23B 238 187 175 F 191 0.049 - 0.48 0.25 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 0.00 0.00 0 0 0 0 0 0 0 0 F 71A-tpl. 0.989 - 27.69 0.00 40 6 176 0 12 2 45 0 6 c) AED exwrsion 432 372 Envelope losslgain 2779 4145 2383 3226 12 a) Infiltration 357 102 360 109 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (litres 6 to 13) 3135 4247 2763 3335 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3135 4247 2763 3335 15 Duct loads 32% 22% 994 948 32% 22% 876 745 Total room load 4129 5195 3639 4080 Air required (cfrn) 192 241 169 189 Calculations approved byACCA to meet all requirements of Manual J Sth Ed wri htsoft' 2014-Aug-2810:52:53 9 RightSulte® Universal Colo 1MJ8 rent Door Page 12 ...cumentalWright�it FiVACITemplatelFt. Pleroa.M CaIc=MJB Front Door faces N Ott m 3 �S B H 0 9 3s am 0 ^C 9 3!� �o T N ay Cpm p w@ "(n ' � w �• m NA w�IJ� D �Q �CALi� �n TT T V Ir�I-� If Irk Ir�I-I�-Ir� Ir rz ImI hI-� � A9.11� A 8 8 8 3 -----'D D-DD >-DDD D➢➢->D>y p'D- yyyyD �hAA� �a 3 3s m o �. 8Y'W o0 0000'00'0 0 0'0'0 0' oa 33 RRaa333�3�333� 3 93,333:� 3 , 33a33 o v a W � � R .6 LN POP 8OQOo��.Oy++++++++Op...p:.+++... p0.....a�NN�N�1jj pJ��, Opp �Pp-- 0> (O (O (m (TI+��WO�0�00001JOfJO000lJO�OCJ O�f�b�(J �(JO��afJ xc P� v �� ��������FFFFFFFFFffmmmmmmmmmmmmm m��» » > � N ( t� V 0000opo OCR 0 O, pA,�i N9LppppppAWg poOApopppp 2 00 ��ONOOOpOp(N����o fOpoopporoi S N00p0 p0 p0 p0 p0 p0 NN�' po po po po po po po po ((ate S S UTA O O O O O O W O O N N S� 8S S S S S wN N N SN O O O w O O O O O O(T G) m o poin$00000000000000p00000000000000000000� 3^ o a m o y O p8CJO O O p O O O o O O p O p p p O o O O O O O O o o p O p O p p O p p0 V ;bq0 X ip H 8 2 N 0 0 0 [j m� O(o 0 0V 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 W 0 8 - mid + 8 0 0 0 OL O O 0419 JJ���� p IO N 11JJ O Ac0 O O O O O O O O O O O O O O O O O O O O O O O O O O O O O p O 0 0 0 p 0 w x m O p 0 0 'm m O O O O 0 O O O O O o o O 0 0 O O O O 0 O OO O9 O O oS O O O O O O 0 A 2 ;x w m� p_1 (J j [[�jj y o mOt0NOOOOOOOOOOOOOOOOOOOOOOOOw000 00000OdSpm>p T"��om 00 (J 00 Om + (�my,y comeoc0000000000000000000000V00OZ9000OOOA QL 0 k� O r t Im u c O O c O c O O O c O o O O O o 00 O O o O O O O O o o O o o O O O O O m o 0 of N 00 co N O O O N M N- 8 U as _ ar i5F` S m O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O Ot0 O O O tD 00 t0 00000 N � O v r m = _ F � J O p U 0 0 0 0 0 0 0 0 0 0 0 0 0 09 O O O O O O O O O O O O O O O O O O O O O H O O OI - y o Y1 d m Z Y o m O C S m O O O O o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o O O O O O O o 0 0 o O O O O o O O o O V O @m 00OOO00000000000O0000oono0000§000000g000 - . r 52 :$0 00 6 000 g o S9 0O0O0O0000000000O0000OOPOOOOOAOO OOoo�000 �c�cSS EEGG p 20 y� § 000§§ g� d O0 KOi X OO 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 08 0 0 0 0 0 0 0 0 0 0 0 0 @ O O O W� 0 m v N a m00 '"'.E 000O0000000000O00000000g00000g000000g000 o 8 NoodoodNdodmoW��NoococoNommoo�dd6dddd6dd HHHHHHH HH HH�iH �i �'�iHHHHH HH HH �i �iHH�HHHHHH��g� = `-' = V'OCOOOOVOOCNON�VI<O000OOd'o VINO0�C0OGGG0001�: �� O ccccc$�mmmmmmmmmmmmmm�y;33333333£'€'E����IIVV LL on nO nO O nO nO O nO o^ O O 'O ^O ^O o^ O on on O mW qm ❑3 OX o b p E mE o 0EiEoEEE0o��oEEoGE 00000o fi)j a,gN cK o aE@ E E �O1omm��{EoEoEo cc - - - - �sff KErE K U 'oc 8¢-d jyK� =�lmj J=X0U �XmS LLLLLL Na R�- m 0 Q J O aC t M r M 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o o o o o o o o o o o o o o o W o o o Cf N 00 00 N 00000 0— _ 8 a .. 0000000000000000000000000000000000000000 m oo m 000mN �� O o < u x r� joy x v 000000000000000.000000o00000000000000N000 O � m R d r z v o oo 0000000000000000000000000000000000v000 N 0 NE a Ci 0.00000000000000000000OORC�00000000004000 90,00 .�- 000ns 8 a� o 000o00o00o0000000O00Ooomom0000000000�000 izo g vS 000s y ++iiSS K2' o = �oi x m o.0000000000000000000000s0000aoo00000soon g? o N is ro F ��m m$ g 0000000000000000000000080000000000008000 - o d o U' 8888888�3888�8���Y3888888�i8��88R888888dX g odd N000000N000 mo momN000000NO Wmoo Nddddciddodd x 88888888'888Y38Y3YiY388888$888Y3Y388�38888880 m d000000a000voj'ova' v00000000v'v�'oov�'cd0000oo0� x O qqpp CCCGCCCddd dd OdddNNNNN333333333�E.'E " " ` 0000 0 p0pgppppppggpp ppppp o 00 000 0 00.- o�p� p� ooFi.o o o a EE '6F o 999 EE E E EEEEE EEE EEEEE EE'+ 0000 0 000000 000 00000oo 00 as gqgqYF V VY c a _ �`-•- ��E ¢VgqVVYqq ,E}VV4 ,E}VVYYV '� m� $ �� E� E E E E3� o mz �. ¢ 88 F ma o.'U LL¢LL .-M400N ro . . f0 C2 N 49 tn 0 O O O O O O o o 0 0 0 0 0 0 0 0� 0 0 0 0 0 0 g 0 0 8 0 0 0 0 0 0 0 0 0 g 0 0 0 I_ y so 00 Q O O O Q1g VA U m 000000000000000ow000000000§000000000m000 t6b ao 0 000012 � m = O O! x Zpl Y.- S O O O O O O O O O O O O O O O O R O O O O O O 2 O O O O O O O O O O O O� O O O W a O m o �g 000000000000000CR000000600WO00000000§000 o �0 0000090o00o0000000000NOOOOO.§oo000O�a.00 ff 7755 R �o 00 9 000P 8 fj ax v n000000$000000000000000cQAff0000OgEO00000Spmo� iiGG tt�� r� go �t66 n� Ooo�� O 0' OOo, x ' R000000rm000000000000000so0oOo0000000No ow. W O m N a >C' x a o "E l�OOOOOoDi0000OOOOOOOOOO.OROOOOOAOOOOoor�2OR O m N .- 0 R �R e �38888888888�8���Yi888888�38��88R888888�Xi88 u NooccooN000 mo mmm�c00000Nomm000000000000 8ggg88gg'88g�8���ggg8888gS��gS�Sggggg��g� =g � COOOOOOOo00xf C1�IA�V00000000NIt1oo�OGGCGCGGG� �� oX o � 9 n EEEE EYj EEE E'({�EEEEE��. EE3�' o_ C Fl O _ y2, C �,EEEEEE 000 3.S �,,EE}} ageq t�i 0 ;m c 5 ry��`mam+E� O�d¢Gde�'d pop poq pEp pEpE ppo ppEo pcq qoq ppE popEp pop Coc 4�qqaq �Qddd¢Q�d¢ddc��QQQQQe�dQ��i��°E '$ E2 CfLTN __{�' ryry C N Q q F rrTTt^lI� S S g S ma LL' KKK aUuuu _ is b wrightsoft, AHU 4 ® Worksheet Job: Date: By: QUICK CALCS, INC. 317ST. LUGE LN., FT. PIERCE, FL34946 Phone 772-4666799 Fax 772-4666796 Email: OUIO(CALCS@AOL.COM 1 Room name AHU 4 GUEST WIC 2 Exposed wall 115:8 It 120j ft 3 Room height 9.4 d ft 9.4 heat/cool ft 4 5 Room dimensions Room area 660.0 ft 6.0 x 6.0 It 36.0 fta Ty I Construction number U-value (Btuh/ft''F) Or HTM (BtuwfN) Area (f2) or perimeter (ft) Load (Btuh) Ama or perimeter (ft) Load (Btuh) Heat Coal Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 1A-clom 0.143 n 255 316 230 0 0 0 0 11 W, 1Aclom. 1Aciam 1Actomd 1A-Aom 1Aclocs 1.270 1.270 • 1.270 1.90 n n n n ne 5.56 35.56 35.56 30.00 4..00 34.77 34.77 34.00 2.55 6' 40. 27 0 27 0 0 0 0 17 213 422 960 1967 0 fib 209 391 1391 840 0 43 0 0 0 0 0 0 0 0 .0 0 0' 0 0 0 0 0 0 0 0 0 1Ac1om 1.270 5.56 34.00 0.43 70.43 10 0 341 0 0 0 0 -G 13A-0ocs OA43 0.143 a a 4.00 255 188 164 657 417 417 0 0 0 0 - 10A-m 10A+n 1Acloin tAclom 1Aclom 1Aclom 1.670 1.670 1.270 1.270 1.270 1:270 a a a a a a 46.76 0.00 0.00 0.00 0.00 0.00 53.19 0.00 0.00 0.00 0.00 0.00 24 0 0 0 -0: 0 0 0 0 0 0 0 1122 0 0 0 0 0 1276 0 0 0 0 0 0 0 0 0 0 0 0 "0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1Aciom 1.270 a 0.00 0.00 0 0 0 0 0 0 0 0 V+J 1Aciom 13A4ocs 1.270 "0.143 e. s 1100 4.00 0.00 2.55 0 348 0 318 0 1272 0 809 0 56 0 56 0 22B 0 144 10A-m 1Actom 1Aclom 1Actom 134-4ocs 1.670 1.270 1.2m 1.270 0.143 s s s a sw 0.00 0.00 0.00 35.56 0,00 0.00 0.00 0.00 34.77 0.00 0 0 0 30 0 0 0 0 30 0 0 0 0 1087 0 0 0 0 _ 1043 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W , �G 1Actom 13A4ocs 10A-m 1Aclom 1Aclom 1Aclom 1Aclomd 1.270 (1143 1.670 1.270 1.270 1.270 1.270 sw w w w w w w 0.00 4.00 0.00 0.00 0.00 0.00 OAO (1110 255 0.00 0.00 0.00 0.00 0.00 0 188 0 0 0 0 0 .. 0 188 0 0 0 0 0 0 753 0 0 0 0 0 0 479 0 0 0 0 0 0 56 0 0 0 0 0 0 56 0 0 0 0 0 0 226 0 0 0 0 0 0 144 0 0 0 0 0 VjJ u 1Aclomd 1"onrd 1A-rlomd_ 13A-4ocs. 1Ac1om 1Actom 12C-Osw 16X19-19md 1.270 1.270 1.270 0.143 1.270 1.270 0.091 0.049 w w w w4.00 nw nw - - 0.00 0.00 0.00 35.56 0.00 0.00 0.79 0.00 0.00 0.00 2.55 70.43 0.00 0.00 0.74 0 0 0 Z7 10 0 0 680 0 0 0 17 0 0 0 680 0 0 0 66 356 0 0 535 0 0 _ 0 42 704 0 0 501 0 0 0 0 0 0 0 36 0 0 0 0 0 0 0 36 0 0 0 0 0 0 0 28 0 0 0 0 0 0 0 27 P :C F F F 19C-19cscp _ 22A-tpl 22A-tpl 0.049 0.969 0.989 - - - 0.00 Z7.69 0.00 0.00 0.00 0.00 0 680 -0 0 116 0 0 3201 0 0 0 0 0 36 0 0 12 0 0 332 0 - - 0 0 0 6 c) AE D exwmion 0 0 Fsvelope loss/gain 12989 9139 812 314 12 a) Infiltration b) Room ventilation 1375 0 394 0 143 0 41 0 13 Internal gains: Occupants 230 Applianceslootther 0 0 0 0 0 0 Subtotal (lines 6 to 13) 14364 9534 1 955 355 Less e#emal load L� transfer 0 0 0 0 0 0 0 0 14 15 Redistribution Subtotal Duct loads 16% 19% 0 14364 2368 0 9534 1811 16% 19% 0 955 157 0 355 67 Total room load Air regttimd(cfm) 16731 623 11344 SM 1112 41 422 23 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsof , RightSulte® Universal 201313.0.15 RSU08101 2014-Aug-28 P17 �iGCA ... cements\Wdghtmft WAC\Template\Ft. Pierm.rut Calc= MJ8 Front Door faces: N age .0 tIm In ¢Z000000000000000000000y2000000000000a�0o o. - i4 iiGG o a1 "O oo 0006 Q U • �b m P N O O O O O O O O O O O O O O O O O O O O O V O O O O O O O O O O O O 2 O� O ZC �N O 00O O, 2 O is f0 � m m Z'� Woi x g000000000000000000000.0800000000000080�o .e Yn U' O r ul a_ mo E sw0000oo000000000000000g0000a0000000soso o w vo§0000000000000y0000 o000000000000000200o o ql 00 Oo y Oooyg p 22GG A«S Bpi e^�S Q g « tS ap Ooyo.-0000 oo ooa0000�0000000000000000000't6 og2o M viO 000C' kN g � « W 2 0 0 0 O O O O O O O O O O O O g 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0�s 0 q O, W O r w a � off, go 9oo00000000000g0000 o.00000000000000ro orWo o p"�.g `RR�.I:Sv'7'�v'3�'g88888g�`RggBl�gg�'Piggg888g8um3�JgSngBg $ N���'�o N�iN�ccoc000N000�ooNococc000N0000000 8�i �i �is8�gn gggSBgggggg�gggggggggggg�gg�g�S Sffi N 0{ RREIIE���� �o O ccccd��mmmmmmmmmwww w((w�7.3;;;;;333'E S. LL O O O O O O O O O O O O O O O O O O O O•- oFi_�F{Fi.cF'"o���c'0'{c^{'0N`,i�`yn�i•o6F�,F{Fi,al�o�Fi.F,.n�i,gy�i,4vF,.o4V^N,8���� �• � O ` a0E EEEEEEE EE 6J 00Yo'0000 oo 3 $04pEE0VEYT0r EVV m �• VE VE'VEVEVEVEEYV V0 �yrc�V� a •� - v l¢arc — - —— A � s0'�0E0 E $' EE a �NiCJ'P im f0 �m � 2m C i7p m �a 5LL :E g Em E rc r G 0 i � c 3 wrightsoft• Right-M Worksheet Job: AHU 4 Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-4666799 Fax 772-4666796 Email: OUIOCWLCS@AOL.COM 1 Room name LIVING 2 Fxfxosed wall Q4.6 ft 3 Room height 9.4 ft heat/cool 4 Room dimensions 1.0 x 391.0 It 5 Room area 391.0 fF Ty Construction U-value Or HTM Area (f(2) Load Area Load number I (StuIVITMF) (Bwftl) or perimeter (ft) (Btuh) or perimeter Heat Cool Gnus NIPIS Heat Cool Gross N/PIS Heat Cool 8 1Aclors n 150 100 413 263 1Ao1om 1.270 1.270 n 5.56 35.55 4.77 34.77 0 0 0 0 1Aolom 1.770 n 35.58 34.77 20 0 711 695 1Aolomd 1,270 n 35.56 34.77 27 0 967 946 11 1Atfom. 1.270 n 0.00 0.00 - 0 _ 0 0 0 VN 134-flocs 0.143 no 4.00 255 27 17 68 43 t-G 1Aoiom 1.270 no 3.5.58 70.43 10 0 341 675 13A-4ocs 0.143 a 4.00 255 188 164 657 417 10A-m 1.670 a 46.76 53.19 24 0 1122 1276 10Aan. 1:670 -e 0.00 0.00 0 0 0 0 1Ao1om 1.270 a 0.00 0.00 0 0. 0 0 1Actom 1.270 a 0.00 0.00 0 0 0 0 1Aotom 1.270 a 0.00 0.00 0 0 0 0 1Aolom 1.270 a 0.00 0.00 0 0 0 0 1Actom 1.270 a O.OD 0.00 0 0 0 0 IActonn 1.270 a 0.00 0.00 0 0 0 0 Vp! 13A,rn s 4.00 255 180 150 Q3 4010A0 1.670 1.270 a 0.00 0.00 0 0 0 0 IA,ol 1Ac1om 1.270 s 0.00 0.00 0 0 0 0 IIL--_1[GGj' 1Aolam 1.270 s 0 0 0 0 1Ac1om 1.143 s 5.56 30.00 4.77 30.00 30 30 1060 1043 W, 1Acllom a143 OX 0m 0 0 0 0 -G 1Ac1om 1.143 sw sw 0 0 0 0 13A-4ats w 4.00 Z55 255 28 28 113 72 1.670 1.270 w 0.00 0.00 0.00 0 0 0 0 IA-cl 1Ao1om 1.270 w 0.00 0.00 0 0 0 0 1Acom 1.270 w 0.00 0.00 0 0 0 0 1Aclom 1.270 w 0.00 0.00 0 0 0 0 1Aclomd 1.270 w 0.00 0.00 0 0 0 0 1Actomd 1.270 w 0.00 0.00 0 0 0 0 to-domd 1.270 w 0.00 0.00 0 0 0 0 to-Momd 1.270 w 0.00 0.00 0 0 0 0 VI! 13A-4ocs 0.143 w4.00 255 27 17 68 42 IL-IG 1Ao1om: 1.270 my 35.56 70.43 10 0 356 704 1Aclam 1.270 my 0.00 0.00 0 0 0 0 P 12C-Osw 0.091 - 0.00 0.00 0 0 0 0 C 16X19-19md 0.049 - 0.79 0.74 391 391 307 2B8 F 19C-19cscp 0.049 - 0.00 0.00 0 0 0 0 F 22A4p1 0.889 - 27.69 0.00 391 65 _ 178B 0 F 22A-tpl 0.989 - 0.00 0.00 0 0 0 0 6 c) AED exunsion 0 Erwelope lossigain 6610 8688 12 a) Infiltration 768 221 b) Room ventilation 0 0 13 Internal gains: Oxupants @ 230 0 0 Applianceslother 0 Subtotal (lines 6 to 13) 9378 7088 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 9378 7088 15 Duct loads 16% 19^,5 1546 1346 Total room load 1%4 8435 Air required(cfnt) 407 463 Calculations approved byACCAtO meet all requirements of Manual J 8th Ed. wrightsaft- RightSuReO Universal 2013 13.0.15 RSU08101 2014-Aug-28 10:52Page:53 ... cuments\Wrightwft WAQTemplatelFt. Plarm.M Calc=MJB Fmnt DDorfamv N