Loading...
HomeMy WebLinkAboutPOOL PLANSFuture htr THESE PLANS AND ALL PROPOSED WORK FARE SUBJECT TO ANY CORRECTIONS 'REQUIRED BY FIELD INSPECTORS THAT ::` MAY BE NECESSARY IN ORDER TO amiss COMPLY WITH ALL APPLICABLE CODES. 1JV7'QZFPW7I0JV I DIRECTIOJVS TO SITE PAYUK ELECTRIC PLUMB FOR FUTURE HEAT PUMP BABY BARRIER GAS ENIA 7 US-1 CUSTOMER HAS 9 EXISTING FENCE is SUN SHELF -SO S.F. PAYUK ELECTRIC SAEGAR File COPY � o?-0110 LUCIE COUNTY BUII. I�(D 5ION REVIEWED FOR UV1EWED BY y; DATE PLANs AND r 1 ST BE KEPT ONJM OR NO INSPECTION WILL BE MADE. 0WIVERSIVA11W A"DJRESSdrTzLJ. # RYAN & TRACY SWINSKEY 1206'WHITE OAK LN. FT. PIERCE 812-6447 DESICJVED BY CEOACESTOJJIEY CELL-772-971-0419 LOUDEN POOLS 4306 S. US-1 17T. PIERCEjFL 772-465-2700 41 YEARS- I,NBOSIJVE:SS i NARVEYE.KOEHNEN Professional Engineer 32831 I 7`06 Elyse Circle Port SL Lucie, FL 34962-3212 Il (772) 489-3035 fex HARVEY E. KOEHNEN Registered Architect AR.9471 7205 Elyse Circle Port St. Lucie, FL 34962-3212 (772) 489-3036 fax � 7 7�2�13 EQUIPMENT LIST 2-300 W. LIGHT 2-300 W- TRANSFORMER 1 1vNX ROX 1 SKIMMER 1 MAIN DRAIN 0 HYDRO JETS 3 RETURNS Vac stub POOLSWEEP Nano-saI CHLORINATOR Start-up CHLORINE 150 gpm lands FILTER 2hp 2speed lands HP PUMP Plumb only HEATER 0 SLIDE 0 DIVE RD. 0 HANDRAIL 0 STEP LADDER SS 1 VAC SET COMPL. s0 LIEr DECK-O-DRAIN 763 SQ. IrT- PATIO 841 SQ. ST. CAP SCANNE: Gallons= BY 13,275 St. Lucie Cou ) —Water Velocity —Max 8ft/sec os per FBC 2010-R4101.6.3 —Pool Barrier to comply with FBC 2010—R4101 —Skimmers comply with FBC 2010—R4101.21.1 — Equipment Foundation 3'x71 cone. slab min 3.5" thick pour in place —Water Heating equipment to comply with FBC 2010—R4101. SWIMOUTS (NO SCALE) Vacuum (In Hg) X 1.13 Feel Of Head ? Pressure (PSI) X 2.31 Feel Of Head Vacuum Head + Pressure Head = Total Dynamic Head HYDRO -STATIC RELIEF DEVICE INSTALLED IN / AREAS THAT EXCEED 1' WATER TABLE IN SHE TRENCH DRAIN MAIN DRAIN POOL DETAIL (NO SCALE) OUTSIDE ANGLE OF REPOSE 6' AND FURTHER - 4" THICK WALLS W//3 REBAR 012' O.C. EACH WAY 3' TO 6' - 6" THICK WALLS W/13 REBAR 012" O.C. EACH WAY 0' TO 3' - 8" THICK WALLS W/13 REBAR 012" Go, EACH WAY NO '• REMOVE GRATE & Y• PER FT-�i WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP LINE WHEN EMPTYING POOL. aVERPoUR DR CAP TEE WHERE APPU'AtaE •. • • :', ti' ;y • .: Syr.: 6"x6" TILE \'!)•: ;'.•: GRATE SHALL 4" SLAB BE SECURED IN INTERIOR 2500 FIBER MIX PLACE SO FINISH 4' " TYP WALL THAT TOOLS ARE REQUIRED FOR REMOVAL STEEL-TEX FORM OR KRAFT WALL 6' TYP. TRENCH DRAIN FLOOR '" #3 0 12" OA.B.W. NOTE: FOR DEPTHS GREATER THAN 6' ADD TREADED?f; r' " • r`. • (1)#3 COVE BAR 06" O.C. PLUG a GRAVEL BE TO PUMP - TYP. WALL SECTION & WELL POINT (NO SCALE) WATER LEVEL POOL PATIO 6 ft.,9 1 T . FROM • POWER SUPPLY 3 fQ Z 1" LIGHT CONDUIT 3 3 UNDERWATER LIGHT NICHE LIGHT ` " •, APPROVED C� NICHEIN i ASEA ' ' GROUND CLAMP F� GUNITE patq •1' ! CONTINUOUS BOND WIRE EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: POOL FINISH '-. COMMON TO POOL STEEL, SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE RAILS & EQUIPMENT FFICIENT TO URE OR SETTLEMENT OCCURISSORROM ENGNEER10N 'UD UNDERMINING IF ANY DOES UNDERWATER LIGHT DETAIL ' COMPACTION TEST OF THE BACKnLLED MATERIAL ARE PROVIDED PRIOR TO THE POURING OF THE PATIO (NCI SCALE) MISC. NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2x6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HANDHOLD TO BE INSTALLED ARE WHERE DECK RAISED +6" ABOVE POOL to" MIN 4 R t i e STEPS (NO SCALE) STEP DETAILS 1. TREAD IS MIN OF 10" 'MOE. 2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED 3. ALL STEPS TO BE SOLID GUNBE 4000 P.S.I. Cw".- THESE PLANS AND ALL PROPOSED WON ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAYBE NECESSARY IN ORDER TO ' ONIPLYWITy ALL APPL1CABi E CO9ES, PIPING SCHEMATIC ' HAA & MNER CUSTOM MOLDED PRODUCTS INC. CMP 25506-32X VGB SINGLE CHANNEL DUA1 OUTLET COMPLIANT 32" CHANNEL DRAIN COMPLIENT W/107.2.1 OF THE 2010 FLORIDA BUILDING CODE 32' CHANNEL DRAIN AND SUMP 25506-320-000 "THREE 2" SOCKET x 2.5" SPIGOT PORTS DEBRIS caa, RF7LUDEO '38.79in' OPEN AREA elAMPO LISTED FLOW RATES "WHITE PVC BODY 'COVER GOES OVER BODY TO GIVE FINISHED LOOK TO PUMP The maximum flow rating for this suction fitting with the center port plugged and outer ports open is 308 GPM (floor) and 212 GPM (wall) when using 2.5" plumbing and 268 GPM (floor) and 192 GPM (wall) when using 2" plumbing. The maximum flow rating for this suction filling with the outer ports plugged and the center part open is 200 GPM (floor) and 168 GPM (wall) when using 2.5" plumbing and 184 GPM (Boar) and 176 GPM (wall) when using 2" plumbing. FloPro (FHPM) Pump Curves IN .... _ -.- ... IEJ IN Lu 70 .:HPM ].5 so IN 4e Fe1.WA 70 ... .: 'o FwM2.0 M _.. PHRM ie toFH#m Lew 3, ea FHPM1 "ai d OoQ to zP s <a sP eo 70 a zo too no 120 IN uo tea IN M tea 190 zoo 110 va zso zoo 2" �2 FLOW GPM ffV.90 HIGH RP0066790 DECK ___\ I ROW OF WATERLINE TILE —6111 WATERLINE r MAX 6 _o" 1 #3 STEEL 0 12" O/C E.W. FLOOR SLOPES 6" i a0R SLOPE _L PF M t of REASONABLY UNGORM AND SOMPLY WITH ARTICLES s e 1 IHBD-5u NE SLOPE OF DiF FLOOR FROM THE SNILOW END WALL TOWARDS ME DEEP AREA SHALL NOT EXCEED 1 FDm IN 7 FOOT 12'-0"I TYPICAL SECTION THRU POOL (NO SCALE) w Copy Pipe Size 6 fps Ups 1' 16 gpm 0.14' 21 gpm 0,23' 1,5' 37 gpm 0.08' 50 gpm 0.14' 2' 62 gpm 0,06' 82 110' 2,5' 88 gpm 0,05' 117 gpm 0.09' 3' 136 gpm 0,04' 181 gpm 0,07' 4' 234 gpm 0,03' 313 gpm 0.05' 6° 1 534 gpm 0,02' 712 gpm 0,03' OAS SHALL to mu GREATER THAN 11 Determine System Flow Rate: Minimum Flow Rate Required: 35 gpm per skimmer 1, Calculate Pool Volume: ___ft_===_x 7.48(gal/Ft) = _________gal (Surface Area) (Average Depth) (Volume in gallons) 2. Determine Flow Rate: __ 13L275___ gal / ___315_______42____+_%XX ___ _XXX____ Determine Pipe Sizes: (Volume) (Turnover Minutes) (Pool Flow Rate) (Feature Flow Rote) (System Flow Rate) Trunk Piping to be_ 2.5 _inch to keep velocity ® 8 fps max. at 117_gpm Maximum System Flow Rate. Return Piping to be_ Y_5._inch to keep velocity 0 8 fps max. of 117 _gpm Maximum System Flow Rate. Main Drain Cover( ------ SEE ABOVE___—_—) System Flow Rate must not exceed approved cover flow rate. (Make and Model) See Engineering Page for Drain Configuration Pump Model JANDY FLOPRO FHPM H.P. 2.0 Total H.P.=H.P.x SeMce factor. I H.p. or more must be 2 speed or variable speed Filter Make JANDY CS Size 150 Fitter min, are; b;ssd an 6a. turnover flow rate pool gal. I360 min. - Flow Rate OMde G.P.M. by Cartridge =.375 or Sod =15 or O.E. = 2 Time Controller make INTERMATIC Model PE 35300 Controls must operate a minimum of two speeds. The higher speed override Is not to exceed one normal cycle or 24 has, whichever Is less 11�.YISf►1AT1]�IT:71 LOUDEN POOLS SWINSKEY RESIDENCE 1205 WHITE OAK LN FT PIERCE, FL Copy ENGINEER: HARVEY E. KOEHNEN PROFESSIONAL ENGINEER PE32831 72M ELYSE CIRCLE PORT ST LUCIE, I L349.;2- (772)J,89-3033 fax s 7/46 M