HomeMy WebLinkAboutNOAM}I�AIttMt�rI1•�
t� MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATrON DIVISION
Miami, Florida 33175.2474
T (786) 315-2590 F (786) 315-2599
OF ACCEPTANCE (NOA)
www.miRmidadexey/building
_NOTICE
Iko Industries Ltd.
40 Hansen Rd. S.
Brampton, Ontario C A
oS�iANNE®
L6W3H4, ,.
LUC Q�
C01jI1Qy
SCOPE:
�dr'thz
This NOA is being issue applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami my and other areas where allowed by the Authority Having Jurisdiction
(AHJ). 0—
This NOA shall not be valid afte ira
Section (In Miami Dade County nd/ e
to have this product or material
perform in the accepted manner,
immediately revoke, modify, or suspen
reserves the right to revoke this acce
Section that this product or material fat s R2E
This product is approved as describefiddis
including the High Velocity Hurricane Zone
DESCRIPTION: Cambridge AR
ion date stated below. The Miam)-Dade County Product Control
AHJ (in areas other than Miami Dade County) reserve the right
1alytys sprance purposes. If this product or material fails to
t``c"11tiiterixal' incur the expense of such testing and the AHJ may
l�s 1 of such product or material within their jurisdiction. BNC
',off Pdetermined by Miami -Dade County Product Control
e requirements of the applicable building code.
�ae ®$een designed to comply with the Florida Building Code
of the Wforida Building Code.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA Is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This revises NOA# 10-0913.02 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 11-0517.09
nm"Ml EExpiration ration Date: 05/05/16
ME Approval Date: 07/07/11
Page 1 of 4
ROOFING ASSEMBLY APPROVAL
Cateeorv-
Roofing
Sub-Cateeory:
Asphalt Shingles
Materials
Laminate
Deck Type:
Wood
SCOPE
This approves a roofing system using Cambridge AR asphalt shingles manufactured by IKO Industries Ltd. as
described in Section 2 of his Notice of Acceptance,
PRODUCT DESCRIPTION
Product
Dimensions Test
Product Description
Specifications
Cambridge AR
13 3/4" x 40 r/e" TAS 110
A heavy weight, fiberglass reinforced
laminate asphalt shingle.
MANUFACTURING LOCATION
1. Kankakee, IL
EviDENCE SUBMITTED
Test Aeencv
Test Identifier
- -
Test Name/Report
Date
-
PRI Construction Materials Inc.
IKO-050-02-01
TAS 100
12/21/09
FM Approvals
3041689
ASTM D 3462
02/23/11
FM Approvals
3036971
ASTM D 3161-(TAS-107)
O1/04/09
FM Approvals
3042673
ASTM E 108
04/12/11
LDmATIONS
I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 913-72 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail W, attached.
S. Nailing shall be in compliance with Detail IT, attached.
NOA No.:11-0517.09
Expiration Date: 05/05/16
Approval Date: 07/07/11
Page 2 of 4
LABELING
1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County
Product Control Approved".
MIAMI•DADE COUNTY
BUILDING PERMIT REQUIRFMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.:11-0517.09
Expiration Date: 05/05/16
Approval Date: 07/07/11
Page 3 of 4
FlRSTCOURSE
DETAIL A
CAmmirlGE AR COURSE LAYOUT
Nola: Roofing Comm not shown In this layout
TKBdrmAnglsformarsaleyautmIy. See Data➢B
for mll g and mment placemant dalalls.
THIRD COURSE
SECOND COURSE
CAMBIUDGE AR
40 8"
13"
6s� 5` EXPOSURE
END OF THIS ACCEPTANCE
NOA No.: 11-0517.09
Explratlon Date: 05/05/16
Approval Date: 07/07/11
Page 4 of 4