FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By .
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
SCANNED
BY
St. Lucie county
FL17084
New
2010
Approved
RESISTO, a division of Snc.
1675 me Haggerty
Drummondville, NON -US
(819) 478-2400 Ext332
memath leu@soprema.ca
Marc Mathieu
memathieu@soprema.ca
Marc Mathieu
1675 me Haggerty
Drummondville, NON -US 000
(819) 478-2400 Et 3327
memathieu@soprema.ca
A
Roofing LIJtie co N ..
Modified Bitumen Roof System VOtyi F�
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
:�6 Evaluation Report - Hardcopy Received
Robert Nleminen
PE-59166
UL LLC
07/29/2017
John W. Knezevich, PE
��7 Validation Checldist - Hardcopy Received
FL17084 RO COI 2014 04 COI-Meminen.pdf
Standard Y ar
ASTM D6163 2000
FM 4470 ppppaaa� 1992
FM 4474 ���� 004C, �0
AEe232015
St. tOe,e Cl UI Nty, FC
1 of 2 10/7/2014 1:22 PM
D
Florida Building Code Online
http://www.floridabuHd rg/pr/pr app dtl.aspx?paramwGEVX...
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
ctrwt.wa.tr t,r or.,nrtt+R
Method 1 Option D
06/20/2014
06/24/2014
06/29/2014
08/25/2014
FL #
Model, Number or Name
Description
17084.1
RESISTO Modified Bitumen
SBS modified bitumen roof systems
Roof Systems
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL17084 RO II 2014 06 FINAL Al ER RESISTO MODBIT F1,17084,pjf
Verified By: Robert Nieminen PE-59166
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-45
Evaluation Reports
Other: 1.) The design pressure noted herein
FL17084 RO AE 2014 06 FINAL ER R MODBIT FL170B4,pd(
pertains to one assembly. Refer to ER Appendix
Created by Independent Third Party: Yes
for all assemblies and maximum design
pressures. 2.) Refer to ER Section 5 for Limits
of Use.
eadi Next,
The State of FbMa k an M/EEO empbyer. Covenant 200T-2013 state eI FEXtla.:; hWty Ratament:; ArrmiMM statement :: Rcnmd Stam nent
Under Fonda law, email addresses are pubic records. ayou do not want your e-ma0 address released in response to a public -records request, do not send electronic
motto this entity. Instant, coMet the offxe by phone or by traditional mall. ayou have any questions, please contact 850.487.1395.'Pursuant to section
455.275(I), 11oMa statutes, effective October 1, 2012, mensees @ensed under Cmpter455, F.S. must provide the Department wth an e:naY addness a they have
one. The emaae provided may houses for official communlnatkn with the fcensee. However ema0 addresses are pubik record. V you do not wish to supply a
personal address, please provide the Department with an anal address which can be made avaaable to the public. Th determine r you are a aeensee under Chapter
455, fi5., please click has,
Pm d b* Approval Aaepts;
CredilfAr
2 of 2 10/7/2014 1:22 PM
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WINO UPUFT RESISTANCE
Table Deck Application
Type Description
UTRINITY JERD
Page
1A Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 2
1B Wood New or Reroof(Tear-Off) F Non -Insulated, Bonded Roof Cover 2
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Base sheet fasteners shall be of sufficient length for minimum 0.75-inch penetration through the wood deck.
3. For mechanically attached components, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter
16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM
LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM-LPDS 1-29 for Zone 2/3 enhancements.
4. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no
rational analysis is permitted.
S. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for
comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1.
6. For existing substrates In a bonded recover installation, the existing substrate shall be examined for compatibility and bond performance with the selected adhesive to the satisfaction of the
AHJ.
7. Unless otherwise noted, refer to. the following references for bonded base, ply or cap sheet applications.
TABLE 1: RESISTO ROOF CovEBs
Reference
Layer
Material
Application
SBS-SA
Base
SA Base
(585, Self -Adhering)
Cap
SA Cap GR '
Self -Adhering
8. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC1609.1.5 for determination of design wind loads.
Exterior Research and Design, U.C. d/b/a TrinityI ERD Evaluation Report 7215.06.14 for FL17084
Certificate of Authorization #9503 Date of Issuance: 06/20/2014
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 1 of 2
tit
�.J TRINITY (ERE)
TABLEIA: WOOD DECKS —NEW CONSTRUCTION OR REROOF(TFAR-OFF)
SYSTEMTYPEE: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
Deck See Note 1
( )
Base Sheet
Primer
Roof Cover
MOP (psf)
Base
Fasten
Attach
No.
Base Primer Cap
Min. 7/16-Inch OSR or
Sopra-G or
32 ga., 1-5/8-inch
6-inch o.c. at the flinch laps and
RESISTO
RESISTO
W 1
min. 15/32-Inch plywood
Modified Sopm G
diameter tin ups with 11
6-Inch o.c. at four (4), equally
EXTERIOR
SBS-SA
EXTERIOR
SBS-SA
-37.S'
ga. annular ring shank nails
spaced, staggered center rows
PRIMER
PRIMER
32 ga., 1-5/8-Inch
7-inch o.c. at the 4-Inch laps and
RESISTO
RESISTO
W-2
Min. 19/32-Inch plywood
Sopm-G
diameter tin ups with 11
7-inch o.c. at three(3), equally
EXTERIOR
SBS-SA
EXTERIOR
SBS-SA
-37.5
ga. annular ring shank nails
spaced, staggered center rows
PRIMER
PRIMER
Min. 15/32-inch OSB or
32 ga., 1-5/8-inch
6-Inch o.c. at the flinch laps and
RESISTO
RESISTO
W-3
min. 15/32-Inch plywood
Sopra-G
diameter tin ups with 11
6-inch o.c at four(4), equally
EXTERIOR
SBS-SA
EXTERIOR
SBS-SA
-45.0
ga. annular ring shank nails
I spaced, staggered center rows
PRIMER
PRIMER
TABLEIB: WOOD DECKS— NEW CONSTRUCTION OR REROOF(TFAR-OFF)
SYSTEM TYPE F:NON-INSULATED, BONDED ROOF COVER
System
Root Cover
No.
Deck (See Note 1)
Primer
MOP(psf)
Joint Treatment
Base
Primer
Cap
Min. 7/36-Inch O5B or min. 15/32-
W 4
Inch plywood
RESISTO EXTERIOR PRIMER
None
SBS-5A
RESISTO EXTERIOR PRIMER
SBS-SA
-45.0
Exterior Research and Design, U.C. d/b/a Tdnityl ERD Evaluation Report 7215.06.14 for FL17084
Certificate of Authorization #9503 Date of Issuance: 06/20/2014
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 2