HomeMy WebLinkAboutSTRUCTURE CALCULATIONSFI C PY 400 �a WIW RNIE �OR GAR CODE COMPLIANCE ST. LUCIE COJd�N,'�'Y BOCC STRUCTURAL CALCULATIONS for Solar Photovoltaic System Project: Bacher Residence Address: 2101 River Hammock Ln, Fort Pierce, FL 34981-4978 GSN: 1903076 INDEX PAGE Scope and Data 1 ENV Data & Calculations 2 Module and Attachment Loads 3 Wind Details & Roof Zones Al Module Specification A2 Attachment Detail A3 Attachment Detail A3a Span Table A4 Rack Certification & Load Table A4a SCANNED BY St. Lucie County GE HO�11j% GENg'S 1,Fp�i�� • STATE OF <U . O FS t O P N�`,� A� 1105 L15-1, VERO BEACH, FL 32960 (772) 205-3244 permitting@goldinsolar.com Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. Project: Bacher Residence No. 1903076 Analyst: Amjad Mardi Revision GO LAR I%E' Engineer: Holly Hoover, PE ", Step 1: Scope and Data Purpose: Determine Wind Loads on MWFRS Solar Equipment Method: Directional Procedure for Appertenances Reference Standards: FBC 2017 (ASCE 7-10/7-16, Chap. 26-30), NEC 2015(Art.690), IBC 2015, HUD hr �— Risk Category II Table 1.5-1 he he Exposure Category C Sec. 26.7.3 1 1 ELEVAMON STRUCTURE DATA ABBR Bldg Type Enclosed Low -Rise <60 ft, hr < LHD Sec. 26.2 Roof Construction Hip Metal, 5v Field Survey (FS) Mean eave height he 8.0 ft FS/Eagleview 50 % eave height 4.0 ft Mean roof height hr 12.1 ft " 40% mean roof height 4.8 ft Calculated Primary Roof Slope 5:12 23 deg Eagleview Parapet height hpt N/A ft FS/Eagleview Mean canopy height ht N/A ft " Building length WL 75.0 ft " 4% building length 3.0 ft " Building width W, (B) 67.0 ft " 10% Least Horiz. Dim. LHD 6.7 ft Calculated Dead Load D 25 psf HUD Live Load L 20 psf " PV MODULE(M)DATA ABBR SOURCE Chord Length LP 5.56 ft Module Spec. (A2) Width w 3.28 ft " Area A 18.25 ftZ (panel : panel gap > 0.25 in) " Thickness T 0.11 ft " Weight W 41.45 lb " Low Module Edge hl 0.5 ft See: Plan Sheet S1, S2 High Module Edge hz 0.5 ft (10 in min.) " Angle to roof w 0 " (tolerance of 2") Calculated Distance to Roof Edge = 2h2 1.0 ft (min.) Test Pressure (Down) P (+) 113 Design Pressure (Down) P (+) 76 psf Test Pressure (Uplift) P (-) -84 Design Pressure (Uplift) P (-) -56 psf 1105 US-1, VERO BEACH, FL 32960 (772) 205-3244 permitting@goldinsolar.com Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. 1 o Project: Bacher Residence No. 1903076 Analyst: Amjad Mardi Revision GOLDIN:SOLAR Engineer: Holly Hoover, PE Step 2-7: ENV Data & Calculations ENVIRONMENTAL DATA ABBR ASCE Source Basic Wind Speed V 159 mph ASCE 7 Hazard Tool Use per Bldg. Dept. V 160 mph Directional factor Kd 0.85 mph Table 26.6-1 Elevation factor Ke 1.0 < 1000 ft Table 26.9-1 Topographic factor Kt 1.0 Table 26.8-1 V pressure exposure K,h 0.90 Table 26.10-1 Gust effect Factor GI 0.85 Rigid Bldg N/A Mean elevation h 12.1 a = 4.0 ft Velocity pressure = q:=h 50 psf = 0.00256 K, Kt Kd VZ h/B = 0.2 Factors Range Equalization 'ya 0.40 (Figure 29.4-8) v ArrayEde g YE 1.50 Exposed (-) 1 1 � � � 1 Array Edge yE 1.00 All (+) Nonexposed (-) ®; o � f'O ;® Parapet '/P - min (1.2, 0.9+hpt/h) 1 1 i .' `. Chord 'yc 0.93 max (0.6+0.06Lp, 0.8) r Is Exposed Panel within 1.51-p 8.3 ft - a %'At Edge Distance > 2h2 dl 1.0 ft (min) Hip roof Array Separation = dz> 4.0 ft Roof Area : 3987 Total Modules: 53 Array Area: 967 Determine Wind Pressures P = gh(GCP)(yE)(ya) Cover: 24% Zone M (it) M (SF) GCP (+) GCp (-) Exposed % 1 48 474 0.3 -1.0 48 100% 2 46 493 0.3 -1.2 46 100% 3 GCP: External pressure coefficient; Table C30.3-8. Hip Roofs, 20" < B <_27" (Figure 30.3-2G) Zone 'YE 0-YE N Ya % 1 1.50 1.00 0.40 51% 2 1.50 1.00 0.40 49% Wind Pressure (psf) P (+) P (-) Module Design 76 -56 Effective 6 -33 Margin 70 -23 OK 1105 US-1, VERO BEACH, FL 32960 (772) 205-3244 EMAIL: PERMITT[NG@GOLD]NSOLAR.COM Note: The Calculations are partof the Construction Documents and shall match in specifications, codes and regulations. 2 , Project: Bacher Residence No. 1903076 Analyst: Amjad Mardi Revision IN,SGOLDOLAR Engineer: Holly Hoover, PE Step: Module & Attachment Loads SUPERIMPOSED LOAD CONNECTOR CAPACITY Roof Dead Load 25 psf Truss Member Type SYP Roof Live Load 20 psf Spacing 24 in o/c Total Load 45 psf Specific Gravity (G) 0.55 Section 2 x 4 in x in Module Weight 2.3 psf Source: NDS 2015 (TR12), FBC 2017 Safety Factor 2 Connector Type Lag Screw Diameter 5/16 in Module Deadload 4.5 psf Penetration 2.5 in (min) Roof Deadload 25 psf Number 2 Live Load 0 psf Total Load 30 psf 30 < 45 OK Withdrawal Capacity Lateral Resistance (Table 12J) W =1800 G3/2D % 307 lb/in 1-3/4", Z 140 lb Short Duration Factor 1.6 Group Factor (Table 11.2.6A) 0.98 lb W * SDF = 1227 lb / screw LR * GF * STF = 220 lb Total Capacity 2455 lb Lateral Pressure (max) 75 psf Uplift Pressure -33 psf Tributory Area 0.5 sf Tributary Area (TA) 12 sf Lateral Load on screws 38 lb/screw Uplift -396 lb Safety Factor 1.67 Assembly Weight/TA 31 lb Shear Force / screw 31 lb Net Tension / 2 screws 2090 lb 31 < 220 Design Load/2 screws 1400 lb OK 2090 > 1400 OK Set Chord Edge Distance (Table 12.5.1C) Set Connector Spacing (Table 12.5.11)) L/D = 8.0 psf L/D 2 6.0; 5D = 1.6 in L/D >_ 6.0; 1.513 = 0.5 in Provide 2.5 in o/c Provide 0.75 in o/c 1105 US-1, VERO BEACH, FL 32960 (772) 205-3244 EMAIL: PERMITTING@GOLDINSOLAR.COM Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. 3 i 4 GOL0' IN 0LAR Wind Details and Roof Zones wiMn mneuncMo O mNtt QmaEa eonE] 74'-e 1105 US-1, VERO BEACH, Fl. 32960 (772) 205-3244 permitting@goldinsolar.com Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. Al GOrDIN:SOLAR iihiaii --- imvtCorer-- - - Pad Corer MODULE SPECIFICATION Iaxbwb= 7085: x50.70rrnsl121n __..._._. _ Pmtnviav Gina lPG7, \iLi �__ _&cda Caale 4rmaSLSr cab'C G)1100Ran, F]IIDDRrn cea."Wr MYI:iTanbeL tAC4. FOGS acd IPGB PmreraIMPPW 1 Sate CNCPIiCxm4t• _ r0 ]CIiultVolu e• Z CcantatHPP ` VClujeat MPP• [NILIe]rya Y- BIMDLOYPERTO VANCEAT NORMAL VERATING COX 315 320 2 330_I ERTOLEPANCE+5T77-0w) _ _I 315 320 325 330 _ 7D.03—_--_1 _ D.74 1020 ..._I 3997 40.13 40.40 40.66 ' 955 9.r.0 9.GG 971 3Z98 3332 33.G5 i 3_396 -- P4r<erat MPP! P� IM 233A 2372 240.9 �- 21.4.G ^ � e 54att ClROlt Rn24C 4_ W 803 834_ .T B.16_ -822 I +.. Ojea ClfcnitvotuEe• Vs IVI- 37_+D 37.54 3779 38.04 I _ `ementzilmP ^_ In U] 7.51 75G 7.G0�_ —7.G4 I VVILIEe it MPP• Ya lYl 31.07 31,9___.___.�_ 3170.,. _. ^_ _. 32.01 , 9DOON4ar. SV:,�ocmin AY iSC _ •'Ymreiarn cknnmSTC�]Y:NCC aST. •FOOxtn, t�2Ls,m,aAY ]AG •7PdlvaLnr a.'YVLm eYy GRa .. I _- j`OCCl15PFAF00.MANGEWAPPANiv.. PFYf011YANCE ATi0191RYADIANCE ra•�ym.Tnrrmi:R nm. a�tz t 1 1 1 1 ecya4awa Pmr¢At tai: xi.Lzu $ --`---- : 1 85% w Para lgml0pus 7. t----� ---� RAsmoamtm N'e+IrP tv 259es1 � 1 I i i ' At Oia\a�T vl- !ra^_a1IWRlICCL C I 'I 1 I' iYL\iRinnC31nS0n1S{CY1el LY 1 1 1 I YmanfJ tR.ascl ttm aCELL5 ZJ3 • _ _ I memtantagycurrc;ocvacmmry. ' a mmLY to t\.rll ( �•r-.�-.�-av�-...pro.. I, 1EI7PEitA7017E COETeICGN75 • Tem;mmrecNinciem W lr�____- a_.mix] �---.at 1 Teaxutore Ccelnde0tMPp, --- _yY _I%7a1�-_0- 1Jpd mrAa PtrtnaT¢ un4R b LiaaLsen Lanam2at� a:.;YrNEtI m STC [aa4111Rs QA'C'IO]axla� ` Maata4m REvtRe COrfPot It. 011 20 Eire Raea) PoSLPcll L0a0� (Pal 5401374000 PeRICe2 j tTeulaaOlaactax4aalxta:0([C61215] On Cmtl4c =.IECU215C[&2tiMGlna(C11LAP;�an6 A cwti1. WMInN LV A938a. ttmemsYaal NlivS<rti ntal Lvlw\rc Soa tb ln�PScn SQCy4SL'Bma9S PtLlta'1 o�t¢nrtcY trim GPatm>:I tartlL'n lmm�vxUn en e�vN lmJatylon 6 am G` N mLPv4R1 1105 U5-1, VERO BEACH, FL 32960 (772) 205-3244 permitting@goldinsolar.com A2 Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. G D w SNMYRAOC SERIES 100 RAOCING SYSTEM TYPICAL ROOF LAIDUT NOTES: - STANDARD LAG BOLT SPEC ASSU1 ES 5116".LAG BOLTS WM 25' EMEDME NT IN ROOF STRUCTURAL HNSERSIRAMRS -TORQUE ALL 5r HARDWARETOTHE FOLLOWING: - SILVER S.S. 10-I6 FT-LBS - BLAOC S.S. 7-9 Fr{ES RAIL CAN MOLNTTO EITHER SIDE OF POST(LPSLOPE 1i DO11NISLOPE) -FOR OR STANDOFF. N DOFF SURFACES; USE NG UP TOTWOLEVELILYG SPACERS PER L FOOT ORSTAYDOLEVEUN DRAWING / STANDARD PAIL IEVELING' FOR DETAILS AND LIMITATIONS ROOF RAFTERS OR STRUCTURAL MUIBERS TLAILEND OVERHANG RMOR OVERHANG RECOM ENDATIONS) dRCTle" Mudly caml ImesattRi awtlq.kn t= ONS PMfT{,l'BHC fCC(I:TPTTOt my y MMIER. Df4m 6100D06 SERIES 100 TYPICAL LAYOUT F [M ejY6tl �� lril<olEOTn: °1R' 120113 GOGDIN 'SOLAR ATTACHMENT DETAIL DESCRIPTION: DRAWN BY: SrM)PNMCh SNAPNRACK METAL ROOF BASE D•RYnn Mounting Suluhens REVISION: -olar PART NUMRER(SX ..r..�.�..r. 242-02037 a s � 7 3 6 2 1 8 2 PARTS LIST ITEM DESCRIPTION 1 ACK METAL ROOF BASE BOTTOM 2 ACK METAL ROOF BASE SL9113tIG WASHER 3 ACK METAL ROOF BASE CAP 4 NGE SERRATED, 5/I61N-1B, SS KSrfflRACjKEAP9O 5 ACK CHANNEL NUT 5/I61N-16 6 ANGED HEX, 5/16I1-18 X 1-1/41N, SS 7 ACC AP9O L. FOOT PRC. CLEAR MATERIALS: 6000 SBUB AWMDVUM, STAINLESS STEEL OPTIONS: DESIGN LOAD (LBS): 700 UP, 330 DOWN, 500 SIDE ULTIMATE LOAD (LBS): 1098 UP, 465 DOWN, 1340 SIDE TORQUE SPECIFICATION: 10+ LB -Fr CERTIFICATION. UL 2703, FILE E359313 WEIGHT (LBS): OA3 1105 LIS-1, VERO BEACH, FL 32960 (407) 985-5322 permitting@goldinsolar.com Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. A4a GO =DL IN150LAR 1r RACK SPAN TABLE :taI _ ti'Fi:!�e M.021 }•�•p}7•it i•¢+iii7� .tii :tt'i::•Sa3'� 3}: 13LF¢7¢•:-J F._¢_j,p13 SF ail tC.:tJ• •iq •CiP.PPa.9e`.gp.:9• SSrOgw.eC+•••�r+••• •9q[wa9 E' :9 Cp• j}i•:¢•F: iEi •: t::c:$t• :F9 :P¢F+. :+ :a:}3.+:$P :e� j9P::xd::c: P '7S:=7t _ =tt :}F: :iY:`Gt=•!!:'t7.•�i:i•:�! _•i- !:= i-:ii:i v•S +v: !v•! Iz !e0 •v- - Ca•tJ] r9. SJ _ „� AA y C pDae:•C.65L1!:..•n _ CaCpDat:!e•CFa :PiFe.f t+CaDaa Pi•iP.:: q �.C•q fti •i •iF j. •¢j.:ife.c•a.3t�•3ia�F7. iaa 7jv.c.a. 7ww F,P ¢+• - _ 411:- N =+P•Saat]LP• 39J:..t.iDL•D• P.! SJ:.•1 a.t •L .e! :::•2F.:it�c}YdLtF�:.7:•:!.Stj3•i7t'}:Lti11�:}:!Y!J 17c--ti7CL o •FL! /C�+Ii� PiYpr.Pp _ P.- q+i-Y w[�-giiPp._:5M:PC-.+F_qe• p _• • • • • 1. n•. Ja LLL Pe..::ia�:+• :s •ii.ipeDa:ee::Pffp. is+ i+:/e0+•e+qi:e. :Mqi ii p: !vi•:.e•:L=•:•••: •cC:.:.tev:••p: YLa:•PL •t.! •.L •._ e..•c!�••_. c1L $z Pv••::r. :.caaaa:SrF!•`ga•.a•c:ir:-+ va• J•"_:.wrtPi:t++ :iFCDav:L:171.11 EE !C•_.: ¢SY 33P. S _+a v:+r.!t•avw }.: :=a•+x Liar!e•, .a.S:P.=!+v• xa }5i Sp we+aa :Pa•Y.v :v: t.p: Saa] :2].•S: •G: :]::•aJ v• - •a: :S cQ: `•SL qew t :Pq, z c9. •a.•":YSS:n11•cP3 LS[.L fa!L -1• -_ :S S•OL •!q b venavCY }}v cQ: +:S+:e.araoa .rr?Pc!J.t1_}irfBicDav +}•cP0•:.+:!f5 a4t•e• f7ira5C ii,.•}ja1}aPIC•a.Rjf/i3•i¢.• 10 '.ay j}S_e�a•.+ifiq "A :vo` C•: SveC :S• :p6. '. S:•Jn av! :J9. Jac9: ::SaJ• ev! o� o- z 't:i7:! !S::}:•:. n.. :}7:tE:J•!- :i=- - -�iF:!•ea: ._ :: `x aa•aD+e.e?i.ei. ea..P:_c.e•ea.vic?w+ wPa.++ _.wa•a.Icie-/.e .va Mwt'•. :.13.. -•vie � ie:. •e>+`L9geee.•,F�-••ea• • 5.+9vae•v1¢.+e•ePw • va ae ♦.: - t : ] v}ca• ::_ n :!SS:LY .a+easai.Di+a•.ee.Yfo•.e2•ae•.aaP :!e:1_:! :z: S:SSeJ •1; _ti :P. -LS .ei-o-a zc: v.caarc•• :: ts!•L:: vav:P•+.e.• 3: :!L __ n __ 9i. !S. _:S. ,=a Y3•Et�:!e .Y:';= :e3/__ _ Y9::e•n '� � Cf veie/CVO•e[iia6i.•pE•.DDi12 I Qe..apOPv.f 4••r.Dv vvf i.atPer5M0)4•i LL'{k:L iQy ati[]ti:!Q5]S• S..i]__F_ftf] Ei.f}iPlQ.L.Q tt!.Q!_sQ! as gtLthac itL hd%kht:hitshitLhktLhitL'Pits4itihi:thv'Lki?phi':hh'Lvt:Lki Ell P32 Q N 5 P 1105 US-1, VERO BEACH, FL 32960 (772) 205-3244 permitting@goldinsolar.com Note: The Calculations are part of the Construction Documents and shall match in specifications, codes and regulations. A4 r 0 O Ln 10 F•s G A O 01 m (Di 2 T LU N LO 01 O D A a W P March 29, 2018 SmpNrack 77SFiemlm,Sm.200 San"Obispo.CA93e01 1tL•(g77)7J2.2850 attn:5esytirxk •[rgLxakyDepartmem Stem Report 020170024CM-Sepl6adSer6s 1005oar f4 of Tile gadksg9Rtemwth WOS•1Sgai1 PM ka -Suu Wil En#seers has been retained No pa 5d: mg'neering services relaxed a the SIu7Nraek Serbs 100 RorkkgSycumu lleamdedspuatablaarcpadded forthe allay (AOSalunk ummi{aAaMilrmsfderatiandthe corsaGbm a rttadmtsA devices. IIgIw 1:StnbnvkwdSeda 100tay,show5lg avagdmemkraandthniluNrumcluudres lhh ktltltertifast'W the aUadledspantablaue In mmpbrmwkhfla dsldngtdeaxdlvnitationprtsordd in P152RAport0201700240003. DIGRALLY SIGVED If Arm taWOLLvh you alypetbm, da notldtaatoal vvsdJ`K..(.C��. E Pmparedb r• PMLM-Stmtbralay'"M Nd.10i+? •k Restv3le,CA 57ATEOFF tc 01. ,..AnME��• 01'A S'mo Cal4go BwraW W14IS0. Row9aa.CA96661 a 9169613MO c 916.96IMSS w wwapmean UD $HE � $�3�Lt EfV�1NE0 Attachment to goof: The attached span tables include consideration of the attachment device capacity. based an UL 2703load testing lmdormed by SapN2ck. Tested latdvalum ae&wdopedwBh 5/16' 0lagsucwswlthaneffedW embedmmtof 2- 1/2' Into a Do ugku Hr substrata, with a reforeme withdrawal (u plHt a pullout) bad apzUty of 5321b, a nd a reference shear (Ode orlateap load apacityaf 270 b for reshtieg short-term wlydor selsmk loads. Reference valuesam the basevalues,befamanyadjusmmtUmadepotho NDi WaIWUms into alternate substrates orwhiel use alwrmte fasteners shah be permitted; provided thatthe fastma has tested or cododerbcd allowable loa d apacities, andmeets one of the followingtwodteda: A( The a0awablelca lvalues forlhe alternate fastalershall meet a=Led the aliawablevaluesnoted above forthe 5/16'0 agsccewsln Douglas Fluor B) thespan length IdenUBed in the'span ables'sha0 be reduced according to the morn restrictive of the following two formulas: Ralf Span = Table Span. Alternate Reference Withdrawl Capacity 5321b Or RnllSpea =TableSpan e Alternate ReferenceSbearCapacity 2701b Thane formulas shall net be used to Increase Iheallonablespan beyond the spans lutd In the spin Latin The span nmtDs have The span aisles have been grwpodalo6mparalesalsalataUvnentdevices a0d'Birts',sddch areprcunted below. To use this able, find theatac memdevice tobeused IntheIbtbelow, then mad acrossa determine which bin the atachmcni lsln. Thespam may then bedelermined Namtheadewith thecomespording Bin number. Structural details for the system and attachments maybe (avid In Appendix C Note Side load drecdon is parallel to rafter. Attachment DeAce Name: hIln No. Madaumgcorflon Loads .Down Up Side 'Standard Base Seam Clamp vAth L-Foot 1 135 235 212 Wide Base Seam Clamp with Vwl UnlvemITIle Hook Fat Tile Hook 2 394 318 417 Hanger Bollaamp Flashed L-Foot(92 Deg) 3 1469 309 2S7 TB0ltepacemml 4 1333 44S 93 AD Purpose L-Foot 190 0eg). Umbrella Counts Kit Corrugated Straddle Block with L Foal Metal RoofBasewithL-Foot S 788 40S 236 Metal Boot Base with 71n Standoff 5.1/21n Standolfan 4-hole Base Wit III) Standoff on 6-Hole Base 'S•1/2N, 7in, orB-1/T Standoff on 1-Hole Base 8.1/2in Standoff on4•Ible Base i 6 788 44S 163 Table 1: Allowable bad Capadgm of SmpNrack 0150 Skmo Calege Bodwmd. Suao ISO. Raoraa. CA 95661 r 916.9613960 < 9101IMS .v wwwpaa.cam A co n sc CT fD 4 �I n d O N CL a O W CL --I W Cr (D