Loading...
HomeMy WebLinkAboutFIELD DENSITY REPORT - ANDERSEN ANDRE CONSULTING ENGINEERSANDERSEN ANDRE CONSULTING ENGINEERS, INC. 834 SW Swan Avenue Port St. Lucie, Florida 34983 Phone: 772-807-9191 Fax: 772-807-9192 www.aaceinc.com FIELD DENSITY TEST REPORT PROJECT: 13054 NW Gilson Road FILE NO: 17-179 Proposed Addition REPORT NO:F�ECEIVED REPORTED TO: Watermark Contractors SCANNED JUN 2 S 2019 CC: BY St. Lucie County ST: 6UEIe 6eunw, PCfffli€ting DATE OF TEST(S): 06/1312019 PAGE NO.: 1 OF 1 TEST NO. 30' x 40' Addition, Pad Fill MDR MOISTURE DENS TM PERCENT DEPTH NO. CONTENT(%) COMPACTION LOCATION (PCF) 1 NWC of Pad 2832 10.9 108.5 97 0 to -12" FS 2 NWC of Pad 2832 11.3 110.1 99 -12" to-24" FS 3 Center of Pad 2832 10.5 109.2 98 0 to -12" FS 4 Center of Pad 2832 9.7 108.4 97 -12" to -24" FS 5 SEC of Pad 2832 10.5 108.9 98 0 to -12" FS 6 SEC of Pad 2832 10.0 107.3 96 -12" to -24" FS ' DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT. " RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS FIELD TEST: F7 ASTM D-2937 F ASTM D-2922 r ASTM D-2167 r ASTM D-1556 TECHNICIAN: SM REMARKS: LABORATORY MOISTURE -DENSITY RELATIONSHIP F= SOIL DIRECTLY BELOW FOOTING FS= FLOOR SLAB SUBGRADE OPTIMUM MAX. GA= SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION MDR NO. MOISTURE TEST M MET ET HOD DENSITY PSSG = STABILIZED SUBGRADE PB=PAVEMENT BASE CONTENT RS=ROADWAY NSSG= NON STABILIZED SUBGRAOE 2832 D1557 111.4 PCF 10.2% SBP= SOIL BELOW PAVEMENT TOP =TOP OF PIPE BOP= BOTTOM OF PIPE BOS = BOTTOM OF STRUCTURE OTHER: Peter G. Andersen, P.E. Fla. Reg: No. 57956 AS MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS. CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRTIFTEN APPROVAL. ANDERSEN ANDRE CONSULTING ENGINEERS, INC. 834 SW Swan Avenue Port St. Lucie, Florida 34983 Phone:772-807-9191 Fax:772-807-9192 www.aaceinc.com MOISTURE -DENSITY RELATIONSHIPS PROJECT: 13064 NW Gilson Road FILE NO: 17-179 Proposed Addition REPORT NO: 1 REPORTED TO: Watermark Contractors PERMIT NO: , TEST METHOD: ASTM-1557 . (STANDARD) (MODIFIED) ■■■■■■■■ ■■■■■■■■■■■■� ■■■■■■■■ram■�■■■■■■��■■■� Owl ON ■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■��■■■■■OMENno ' ■■NN■■■■■NON■■■■■■■■■■N■�■E■N■��: ■■N■NN■■■NON■N■■■■■■■■■■■■■►�■■NM■■■ ENE ■■■■M■■■NM■■■NMM■■■■■■MNMM■M\.\\M■ENE MEE SAMPLE NO: 2832 DESCRIPTION: Brown fine DATE SAMPLED: 06/13/2019 DATE TESTED: 06/14/2019 SAMPLE LOCATION: Composite of pad fill (2') sand with traces of BY: SM BY: SM Peter G. Andersen, P.E. Fla. Reg. No. 57956 AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.