HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEProject Name:
--- - Project Address:
Permit #:
FIDE COPY
Planning & Development Services Department RECEIVED
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462- 553 )^aY ®7 2019
Certification for Design Load Compliance ST. Lucie eeunty, PWITIMln8
Type: SEA Construction
County
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
• Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Building Cade Fifth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D
4. Design Wind Velocity 160 mph X ASD _LRFD End Zone Width: 6 It
5. Mean Roof Height 16 ft Roof Pitch: 6 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
+-" .0 C Le- o J-V -O 417`1t d 3yr7: d"b? 9
Zone 1: - 31, % Zone 2: - IS. 3 Zone 3: - fl, } Zone 4: Zone 5:^Y6 ,5- Garage: A.
7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: wA PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not:
Aspect Ratio < 4:1
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Donald J Nuelle 52046
Print Name Cert # & Co. Cert Auth.
Nuelle Engineering
Signa ,.Date, and',, r� 11634 SW Rowena Str. P.S.L. 34987
✓ G9 Company Name & Address
Revised 07/25/2014 '