Loading...
HomeMy WebLinkAboutNOAJ FILE O PYRECEIVED MAY 0 8 1019 __ COUNTY ICONTROL uAMI-DADE c.DaenC MIAM4�E1♦ per mst. �iUin9 - PRODUCT SEC IT ON 11805 SW 26 Street, Room 208 _ DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 SCANNED Irvine, CA 92618 BY SCOPE: St. Lucie County This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Plantation Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #15-0721.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino P NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date. 10/11/18 Page 1 of 8 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Boral Plantation Concrete Roof Tile, as manufactured by Boral Roofing, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Applicant Plantation Tile Trim Pieces Length: 16%2" Width: 13" L = vanes W = varies Varying thickness 2.1. MANUFACTURING LOCATION 1. Okeechobee, FL Test Specifications TAS 112 2.2 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polyse& AH-160 TILE BOND' Roof Tile Adhesive DAP Foam Touch N Seal StormBone 2 Roof Tile Adhesive Quikrete" Roof Tile Mortar, FL-15 MIAMMADECOUNW F.—TH 1 TAS 112 Product Description Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Two component polyurethane foam adhesive. Premixed, pre -bagged gray roof tile mortar. Product Description Flat concrete roof tile for direct deck or battened nail -on, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. The Dow Chemical Company Dap Foam, Inc. The Quikrete Companies, Inc. NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 2 of 8 2.3 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date American Test Lab of South RT0624.05-14 TAS 112 07/03/14 ' Florida Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III PA 102 & PA 102(A) The Center for Applied 94-060B Static Uplift Testing March, 1994 Engineering, Inc. 94-084 PA 101 (Adhesive Set) May 1994 (Mortar Set) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II PA 108 (Nail -On) Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 PA 108 (Nail -On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 PA 108 (Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test 9MDC-76 PA 100 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 April 1999 Walker Engineering, Inc. Calculations 25-7183 March 1995 25-7094 February 1996 25-7496 April 1996 Walker Engineering, Inc. Calculations 25-7584 December 1996 25-7804b-8 25-78044 & 5 25-7848-6 Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 Farabaugh Engineering and T295-11 TAS-108 10/05/11 Testing Inc. Farabaugh Engineering and T306-11 TAS-108 10/04/11 Testing Inc. Farabaugh Engineering and T279-11 TAS-108 09/23/11 Testing Inc. PRI Construction Material DAPF-004-02-08 TAS 101 07/26/18 Technologies DAPF-004-02-09 Static Uplift Resistance 07/26/18 DAPF-004-02-10 ' Adhesive Set 07/26/18 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test NOA No.: 18-0829.02 1MFDADE COUNiY U Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 3 of 8 in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length-1 (ft) Width-w (ft) Plantation Tile 11.6 1.375 1.08 Table 2: Aerodynamic Multipliers - 2, (0) Tile Profile X (ft3) Batten Application % (ft3) Direct Deck Application Plantation Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity - M (ft.-Ibf) Tile Greater than Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Deck Deck Deck Deck Deck Deck Plantation 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Tile NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 4 of 8 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) For Nail -On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (Min 15132" (Min. 19132" plywood) plywood) Plantation Tile 2-10d Ring Shank 30.9 38.1 17.2 Nails 1-10d Smooth or 7.3 9.8 4.9 Screw Shank Nail 2-10d Smooth or 14.0 18.8 7.4 Screw Shank Nails 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or 24.3 24.3 24.2 Screw Shank Nail Field Clip) 1-10d Smooth or 19.0 19.0 22.1 Screw Shank Nail Eave Clip) 2-10d Smooth or 35.5 35.5 34.8 Screw Shank Nails Field Clip) 2-10d Smooth or 31.9 31.9 32.2 Screw Shank Nails Eave Clip) 2-10d Ring Shank 50.3 65.5 48.3 Nails' 1 Installation w th a 4" Ule headlap and fasteners are located a minimum of 2'/:°from the head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) For Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesive 2 See manufactures component approval for installation requirements. 3 The Dow Chemical Co. TILE BONDW Roof Tile Adhesive weight per patty 13.9 grams. 31.3 4 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two -Component weight per patty 8 grams. 31.3 5 DAP Foam Touch N Seal StormBondo 2 Roof Tile Adhesive weight per paddy 8 grams. 45 NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 5 of 8 Table 6: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf) For Single Patty Adhesive Set S stems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesive6 6 See manufactures component approval for installation requirements. 7 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset®AH-160 Two -Component weight per patty 45 grams. 118.9 8 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset®AH-160 Two -Component weight per patty 24 grams 40.4 9 DAP Foam Touch N Seal Storm Bond® 2 Roof Tile Adhesive weight per paddy 45 grams. 73 10 DAP Foam Touch N Seal Storm Bond® 2 Roof Tile Adhesive weight per paddy 24 grams 48 Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Plantation Tile Mortar Sets 1 39.0 Seespecific mortar manufacturer's Notice of Acceptance. 5. LABELING All tiles shall bear the imprint or identifiable marling of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". OR E NT E [S R R BORAL PLANTATION ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 6 of 8 NOA No.: 18-0829.02 MIAMMADECOUNW Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 7 of 8 PROFILE DRAWING BORAL PLANTATION FLAT CONCRETE TILE END OF THIS ACCEPTANCE NOA No.: 18-0829.02 Expiration Date: 12/08/20 Approval Date: 10/11/18 Page 8 of 8