HomeMy WebLinkAboutNOAJ
FILE O PYRECEIVED
MAY 0 8 1019
__
COUNTY
ICONTROL
uAMI-DADE
c.DaenC
MIAM4�E1♦ per mst. �iUin9
-
PRODUCT SEC IT ON
11805 SW 26 Street, Room 208
_ DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.eov/economy
Boral Roofing, LLC
7575 Irvine Center Drive, Suite 100 SCANNED
Irvine, CA 92618 BY
SCOPE: St. Lucie County
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Plantation Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA #15-0721.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy Semino P
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date. 10/11/18
Page 1 of 8
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Boral Plantation Concrete Roof Tile, as manufactured by Boral Roofing, LLC
in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida
Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined
by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS
127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based
system.
2. PRODUCT DESCRIPTION
Manufactured by Dimensions
Applicant
Plantation Tile
Trim Pieces
Length: 16%2"
Width: 13"
L = vanes
W = varies
Varying thickness
2.1. MANUFACTURING LOCATION
1. Okeechobee, FL
Test
Specifications
TAS 112
2.2 PRODUCTS MANUFACTURED BY OTHERS
Product Name
ICP Adhesives Polyse& AH-160
TILE BOND' Roof Tile Adhesive
DAP Foam Touch N Seal
StormBone 2 Roof Tile Adhesive
Quikrete" Roof Tile Mortar, FL-15
MIAMMADECOUNW
F.—TH 1
TAS 112
Product Description
Two component polyurethane
foam adhesive.
Single component polyurethane
foam roof tile adhesive.
Two component polyurethane
foam adhesive.
Premixed, pre -bagged gray roof tile
mortar.
Product
Description
Flat concrete roof tile for direct deck or
battened nail -on, mortar or adhesive set
applications.
Accessory trim, concrete roof pieces for
use at hips, rakes, ridges and valley
terminations. Manufactured for each tile
profile.
Manufacturer
(With Current NOA)
ICP Adhesives and Sealants, Inc.
The Dow Chemical Company
Dap Foam, Inc.
The Quikrete Companies, Inc.
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 2 of 8
2.3 SUBMITTED EVIDENCE:
Test Agency
Test Identifier
Test Name/Report
Date
American Test Lab of South
RT0624.05-14
TAS 112
07/03/14
' Florida
Redland Technologies
7161-03
Static Uplift Testing
Dec. 1991
Appendix III
PA 102 & PA 102(A)
The Center for Applied
94-060B
Static Uplift Testing
March, 1994
Engineering, Inc.
94-084
PA 101 (Adhesive Set)
May 1994
(Mortar Set)
Redland Technologies
7161-03
Wind Tunnel Testing
Dec. 1991
Appendix II
PA 108 (Nail -On)
Redland Technologies
Letter Dated Aug. 1, 1994
Wind Tunnel Testing
Aug. 1994
PA 108 (Nail -On)
Redland Technologies
P0631-01
Wind Tunnel Testing
July 1994
PA 108 (Mortar Set)
Redland Technologies
P0402
Withdrawal Resistance Testing of
Sept. 1993
screw vs. smooth shank nails
The Center for Applied
Project No. 307025
Wind Driven Rain
Oct. 1994
Engineering, Inc.
Test 9MDC-76
PA 100
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplier
March 1999
April 1999
Walker Engineering, Inc.
Calculations
25-7183
March 1995
25-7094
February 1996
25-7496
April 1996
Walker Engineering, Inc.
Calculations
25-7584
December 1996
25-7804b-8
25-78044 & 5
25-7848-6
Walker Engineering, Inc.
Calculations
Two Patty Adhesive Set System
April 1999
Farabaugh Engineering and
T295-11
TAS-108
10/05/11
Testing Inc.
Farabaugh Engineering and
T306-11
TAS-108
10/04/11
Testing Inc.
Farabaugh Engineering and
T279-11
TAS-108
09/23/11
Testing Inc.
PRI Construction Material
DAPF-004-02-08
TAS 101
07/26/18
Technologies
DAPF-004-02-09
Static Uplift Resistance
07/26/18
DAPF-004-02-10
' Adhesive Set
07/26/18
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
NOA No.: 18-0829.02
1MFDADE COUNiY
U Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 3 of 8
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product
Control office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61G20-3 of the Florida Administrative Code.
4. INSTALLATION
4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application
Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (Ibf)
Length-1 (ft)
Width-w (ft)
Plantation Tile
11.6
1.375
1.08
Table 2: Aerodynamic Multipliers - 2, (0)
Tile
Profile
X (ft3)
Batten Application
% (ft3)
Direct Deck Application
Plantation Tile
0.267
0.289
Table 3: Restoring Moments due to Gravity - M (ft.-Ibf)
Tile
Greater than
Profile
2":12"
3":12"
4":12"
5":12"
6":12"
7":12"
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Deck
Deck
Deck
Deck
Deck
Deck
Plantation
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04
Tile
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 4 of 8
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
For Nail -On Systems
Tile
Fastener Type
Direct Deck
Direct Deck
Battens
Profile
(Min 15132"
(Min. 19132"
plywood)
plywood)
Plantation Tile
2-10d Ring Shank
30.9
38.1
17.2
Nails
1-10d Smooth or
7.3
9.8
4.9
Screw Shank Nail
2-10d Smooth or
14.0
18.8
7.4
Screw Shank Nails
1 #8 Screw
30.8
30.8
18.2
2 #8 Screw
51.7
51.7
24.4
1-10d Smooth or
24.3
24.3
24.2
Screw Shank Nail
Field Clip)
1-10d Smooth or
19.0
19.0
22.1
Screw Shank Nail
Eave Clip)
2-10d Smooth or
35.5
35.5
34.8
Screw Shank Nails
Field Clip)
2-10d Smooth or
31.9
31.9
32.2
Screw Shank Nails
Eave Clip)
2-10d Ring Shank
50.3
65.5
48.3
Nails'
1 Installation w th a 4" Ule headlap and fasteners are located a minimum of 2'/:°from the head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
For Two Patty Adhesive Set Systems
Tile Profile
Tile Application
Minimum Attachment
Resistance
Plantation Tile
Adhesive
2 See manufactures component approval for installation requirements.
3 The Dow Chemical Co. TILE BONDW Roof Tile Adhesive weight per patty 13.9 grams.
31.3
4 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two -Component weight per patty
8 grams. 31.3
5 DAP Foam Touch N Seal StormBondo 2 Roof Tile Adhesive weight per paddy 8 grams.
45
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 5 of 8
Table 6: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf)
For Single Patty Adhesive Set S stems
Tile Profile
Tile Application
Minimum Attachment Resistance
Plantation Tile
Adhesive6
6
See manufactures component approval for installation requirements.
7
ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset®AH-160 Two -Component weight per patty 45 grams.
118.9
8
ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset®AH-160 Two -Component weight per patty 24 grams
40.4
9
DAP Foam Touch N Seal Storm Bond® 2 Roof Tile Adhesive weight per paddy 45 grams.
73
10
DAP Foam Touch N Seal Storm Bond® 2 Roof Tile Adhesive weight per paddy 24 grams
48
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf)
for Mortar Set Systems
Tile Profile
Tile Application
Attachment
Resistance
Plantation Tile
Mortar Sets
1 39.0
Seespecific mortar manufacturer's Notice of Acceptance.
5. LABELING
All tiles shall bear the imprint or identifiable marling of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
OR
E NT E [S R R
BORAL PLANTATION ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 6 of 8
NOA No.: 18-0829.02
MIAMMADECOUNW Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 7 of 8
PROFILE DRAWING
BORAL PLANTATION FLAT CONCRETE TILE
END OF THIS ACCEPTANCE
NOA No.: 18-0829.02
Expiration Date: 12/08/20
Approval Date: 10/11/18
Page 8 of 8