HomeMy WebLinkAboutPRODUCT APPROVALPT r- f`^"""'
KIS Home I Log In I User Reguhlb.n I Hot Topics I Submit Surcharge I SUM &Facts I Publimtlore
aIt`� � Product Approval
R USER: Public User
Pmduct AnnmVzl Menu> Product, or Aoplim[ nSea rich >_AgWlca0ion ❑st>Application octal[.
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL11602-R7
Revision
2017
Approved
REC51\10
Mg o a 10%
Pet... Lucie Count ent -
Owens Corning Roofing and Asphalt, LLC
One Owens Corning Parkway
Toledo, OH 43645
(740) 321-6345
Greg.Keeler@owenscoming.com
Keeler Greg
Greg.Keeler@owenscoming.com
Greg Keeler
2790 Columbus Road
Granville, OH 43023
(740) 321-6345
greg.keeler@owenscarnlng.com
Roofing
Undedayments
SCANNED
BY
St. Luce County
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
01 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida license PE-59166
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 09/30/2019
Validated By John W. Knezevich, PE
+!' Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
i-..•I • I - I • . u.. . ..1
Standard
ASTM D1970
ASTM D226 (physicals)
ASTM D4798
FRSA/TRI April 2012
TAS 117(B)
Year
2015
2009
2011
2012
1995
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/16/2018
Date Validated 10/08/2018
Date Pending FBC Approval 08/23/2018
Date Approved 10/18/2018
Summary of Products
FL #
Model, Number or Name
Description
11602.1
Titanium Roof Underlayments
Synthetic sheet -type roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
E11602 R7 II 2018 09 FINAL2 ER OWENS
Approved for use outside HVHZ: Yes
CORNING FL31602-R7.udf
Impact Resistant: N/A
Verified By: Robert Nleminen PE-59166
Design Pressure: +N/A/-45
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use of
Evaluation Reports
a specific underlayment system beneath foam -on tile sytsems.
FL11602 R7 AE 2018 09 FINAL2 ER OW ENS
Refer to ER Section 5.6.3 for details. 2.) Refer to ER Sections 5
CORNING FLI1602-117.odf
and 6 for other Limits of Use.
Created by Independent Third Party: Yes
Santsa US:: 2601 Slalr Stone Road Tallahassee R 32399 Phone: 850487-1824
The State of Florida is an AA/EEO employer. fWl_llght 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email address" are public records. If you do not want your a -mall address released in response to a public-recprds request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.175(1),
Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address if they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public To determine If you are a licensee under chapter 455, F.S., please click here
Product Approval Accepts:
-a 4
secnrityetETntcs
2/13/2018
_ r
Florida Building Code Online
FILE Cr
BCIS Home I tog In 1 User ReglsVatbn 1 Hot Topics I submit surcharge I stats&Facts I Publiratlons
d Florida
;� `� � Product Approval
pwnp i UBER:Peblic User
6i%miigrmi
ProduRAm.>PraP5> aplolicaBonllstoApplicatlon Derail-- -
FL #
FL20378-Rl
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
(!
Product Manufacturer
Extreme Metal Fabricators, LLC
Address/Phone/Email
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
fivalidation@yahoo.com
Authorized Signature
Richard McKuhen
Rvaildation@yahoo.com
Technical Representative
Richard McKuhen
Address/Phone/Email
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
richard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
-RECEIVED
MAY0B101,
Pgrynitting Department
Lucie County
SCANNED
BY
St. Lucie Countv
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
-;i; Validation Checklist - Hardcopy Received
Certificate of Independence
FL20378 R1 AFL 20378.1 NAILSTRIP 1.0 .032 ALUM sss.odf
Referenced Standard and Year (of Standard) Standard Year
TAS 125 2003
UL 1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
hftpsJANww.floridabuilding.org/prlpr app_dfl.aspx7param-wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa%2fE%2fov tglbhDVU2dib4TAA%3d%3d 1/4
2/13/2018
Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 12/18/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/19/2017
Summary of Products
FL 7f
Model, Number or Name
Description
20378.1
01 - "I' Nailstrip"
0.032" Aluminum Standing Seam roof panel, 12" wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378 Rl_II_FL 20378.1 NAILSTRIP 1.0 032
Approved for use outside HVHZ: Yes
ALUM_sss.odf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for Limitations and
Evaluation Reports
Conditions of Use. Refer to manufacturer's Installation
2J=1 0378_@b_&g_FL 20378.1 NAILSTRIP 1.0 ,0',r�
Instructions.
L�UM ss.
Created by Independent Third Party: Yes
20378.2
02 - "1" Nailstrip"
26-gauge Steel Standing Seam roof panel, 16" wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners and adhesive.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
IF 2037 _81_ILFL 20378.2 Extreme Metal Fabricators 26GAA
NAIL STRIP 1.0.odf
Approved for use outside HVHZ: Yes
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for Limitations and
Evaluation Reports
Conditions of Use. Refer to manufacturer's Installation
FL20378 Rl-6E—FL 20378.2Extreme Metal Fabricators
26GA NAIL STRIP 1.0.pd
instructions.
Created by Independent Third Party: Yes
20378.3
03 - "1.75 Snap Lock"
0.032" Aluminum Standing Seam roof panel, 18" wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FFL U778_RLILFL 20378.3 SNAP LOCK ALUM 1.75-ssr.odf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for Limitations and
FL20378_B1—AE—FL 20378.3 SNAP LOCK ALUM 1.75-ssr.odf
Conditions of Use. Refer to manufacturer's Installation
Created by Independent Third Party: Yes
Instructions.
20378.4
04 - "1.75" Snap Lock"
24-gauge Steel Standing Seam roof panel, 18" wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No0
7@_RLILFL 20378.4 1.75 SNAP LOCK 24GA-ssr.odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for Limitations and
FL20378_U_ EFL 20378.4 1,75 SNAP LOCK 24GA-ssr.pdf
Conditions of Use. Refer to manufacturer's Installation
Created by Independent Third Party: Yes
instructions.
20378.5
05 - "Rib Panel"
29-gauge Steel exposed fastener roof panel, 36" wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378=U—ILFL 20378.5 RIB 29GA ssr.pdf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for Limitations and
FL20378 RL6E FL 20378.5 RIB 29GA ssr.odf
Conditions of Use. Refer to manufacturer's installation
Created by Independent Third Party: Yes
instructions.
https!/www.floridabuilding.org/pr/pr_app_dtl.aspx?pamm=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa%2fE%2fov tglbhDVU2dJO4TAA°/a3d%3d 214
2/13/2018
Florida Building Code Online
20378.6
06 - "5V Crimp"
26-gauge Steel exposed fastener roof panel, 24" wide,
mechanically attached to 15/32" Plywood or Wood Deck
w/fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378 RU-U—FL 20378.6_SV Crimp ss. d
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for Method 1 and Method 2
FL20378_RI_M_FL 20378.6 5V Crimp sss. d
fastening. Limitations and Conditions of Use. Refer to
Created by Independent Third Party: Yes
manufacturer's installation Instructions.
20378.7
07 -"1.5 Standing Seam"
24-gauge Steel Standing Seam roof panel, 16" wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips, fasteners and adhesive
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378_9I U_FL 20378.7 JM STANDING SEAM off? f
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for Limitations and
FL20378 RI_!AF_FL 20378.7 JM STANDING SEAM_OL ildf
Created by Independent Third Party: Yes
Conditions of Use. Refer to manufacturer's Installation
instructions.
20378.8
08 - "Nordman Tile"
24-gauge Steel metal roof tile panel mechanically attached to
15/32" plywood or Woad Deck with fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL2038_RI_Id_FL 20378.8_NORDMAN TILE 24GA_ssr.odf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for Limitations and
FL20378_RI_AFL 20378.8 NORDMAN TILE 24GA ss r.odf
Created by Independent Third Party: Yes
Conditions of Use. Refer to manufacturer's Installation
instructions.
20378.9
09 - "Nordman Tile"
24-gauge Steel metal roof tile panel mechanically attached to
Steel Deck with fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378_RiII_FL 20378.9 Nordman Tile Details-ssr.odf
Approved for use outside HVHZ: Yes
Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E.
Impact Resistant: No
#31242
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for Limitations and
Evaluation Reports
Conditions of Use. Refer to manufacturer's Installation
L2�_gl AF FL 20378.9 Nordman Tile Details-ssr.odf
instructions.
Created by Independent Third Party: Yes
20378.10
10 - "Nordman Tile"
0.032" Aluminum metal roof tile panel mechanically attached
to 15/32" plywood or Wood Deck with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378 RI_ILFL 20378.10 NORD TILT .032 ALUM-ssr.Ddf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for Limitations and
FL20376 RI_AE FL 20378.10 NORD TILT .032 ALUM-ssr.Ddf
Conditions of Use. Refer to manufacturer's installation
Created by Independent Third Party: Yes
Instructions.
Bark theft
onContact Us :: 2601 Blair Stone Road. T811ahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer, 9gm(jjght 2007-2013 State of Florida.:: Pdvacv Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public revoms. If you do not want your a -mall address released In response to a public -retards request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section
4SS.275(1), Honda Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department with an email address which can he made available to the public. To determine if you are a licensee under Chapter 45S, F.S.,
Product Approval Accepts:
mi PD10-01 ® esk M
securit)'IaL-rlucs•
https:IA w .floddabuilding.org/pr/pr app_ t1.aspx7param=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa%2fE%2fov tglbhDVU2dJO4TAAa/o3da/pad 3/4
2160 SW Poma Drive
Palm City, FL 34990
( 772)872-8034
Compliant with Florida Building Code 2017 (61h ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Metal Roofing Panel Corrosion Resistant FBC Sec. 1507.4.3
Yield strength: 40ksi Steel Attached to min.15/32" plywood or Wood Deck w/ min.
Attached 24" OA2 specific gravity with screws. 24" Coverage
Coverage Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1506,1507
Fastener for Method 1 Attachment # 9-15 x 1"Hex Head w/EPDM Bonded Steel Washer
to penetrate 3/16" thru wood decking
Fastener for Method 2 Attachment # 9-15 x 1rr Hex Head w/EPDM Bonded Steel Washer
to penetrate 3/16" thru 15/32"min. plywood deck or 5/8" into wood plank
Underlayment: To be compliant with FBC Sec.1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable Loads METHOD 1 METHOD 2 . ASTENER PLACEMENT
DESIGN PRESSURE* -85 PSF-114.25 PSF MEMO IN RIB PEAKS
ROW SPACING 12" O.C. 12" O.C. METHOD ] IN PANEL FLATS
tFASTENERSPACING 12"D.C. 12"O.C, "SEE INSTALL DRAWINGS
FASTENER SIZE: #9 #9
*ALLOWABLE DESIGN PRESSURE MARGIN OF 2 TO 1
Reference Data: HURRICANE TEST LAB #TST ID: 1527
TAS 125-03 Test # 0223-0307-01; METHOD 1 (UL 1897-041)
TAS-125-03 Test # 0223-0517-06, METHOD 2
EQUIVALENCY UL 1097-04 IS EQUIVALENT TO UL 1997-12 TEST STANDARD • DESIGN PRESSURE SAFETY MARIGIN 2:1
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial Interest In any company manufacturing or distributinf produ
under this evaluation. •�itLttt4t{iI p rr;ri,,
Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or distributlrlgjtFod its j, def.tE
report. •�\GIi;V;;�•' • ,'�
S S7Aie.OF `,4.1Z
X.
�r�r:At. :;a+'
Compliance Statement: These products herein evaluated have demonstrated compliance with the Florida Building Code 2017
0 ed., with referenced documents submitted.
Limitations:
1. Underlayment to be compliance with current Florida Building Code 2017 6t^ ed-Section 1507.1.1
2. Products are compliant for State of Florida product approval per Rule 61G20-3
3. Compliance Method: 1-D
4. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
S. All support framing compliant w/ Florida Building Code 2017, Chapters 22 for Steel, 23 for Wood and 16 for
Structural Loading. Design of support and attachment to the framing is outside the scope of this evaluation.
6. Rule 61G20-3 allows for engineering analysis by registered/licensed others for "project specific approval' by local
authorities, authorized by the code, and is the responsibility of others.
7. This report does not imply warranty, installation, recommended product use outside of this report.
-1fi+3T a greater Py^6Wd, a
- Wood plank
Fasteners -
-1532" orgreater Plywood, or
Wood plank