HomeMy WebLinkAboutEVALUATION REPORT1 EXTERIOR RESEARCH & DESIGN, I.I.C.
` SCANNED Cerbftte of Authorization N9503
TiUN�"rY' ERD BY 353 CHRISTIAN STREET, UNIT #13
OXFORD, Cr 06478
EVALUATION REPORT
St. Lucie County (203) 262-9245
i c a Entegra Roof Tile, LLC Evaluation Report E39310.11.11-1-R4
t �d i —GR 1289 NE 9`" Avenue FL7804-R10
R Cr to F T i L E Okeechobee, FL 34972 Date of Issuance: li/0211011
SCOPE: (602) SiS-6933 Revision 4:10/17/2017
This Evaluation Report is issued under Rule 614320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the a Edition (2017) Florida Building Code
(HVHZ) sections noted herein.
DEsciRPTION Entegra Concrete Roof Tiles (HVHZ jurisdictions)
LaaEUNG:' ,Labeling shall be In accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report Is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code, requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report, number preceded by the words 'Trinity] ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPEcnoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages through 8.
Prepared by. -
Robert J.M. Nieminen, P.E.
Florida Registration Na 59I66, Florida MANEJ9R3
The haNNe by Rohm NLn6fv
P.L on 10t SIP iT. Thmaoe, net urveasaneipgAa(�M d la h
tlatimmt SkRo4w4dAaNeaF'�ArmhoantrnuntiNedmtle
LERnnCATiON OF INDEPENDENCE]
L TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing products it evaluates.
2. TrinityI ERD is not owned, operated or controlled by any companymanufacturing or distributing products itevaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being Issued.
4, Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved In the approval process of the
product
S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report; or previous versions thereof, is/was used for permitting or design guidance unlessretained
specifically for that purpose. _
RINITY ERD
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product CategonRoofing
Sub -Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance Is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS-
Section
Pro
Standard
Year
1523.65.2
Physical Properties
TAS 112
1945
1523.6.5.2
wind Driven Rain.
TAS100
1995
1523.(i.5.2.2
Static Uplift Resistance
TAS 101
1995
1523.6.5.13
Static Uplift Resistance
TAS 102
1995.
1523.6.5.2.3
Static Uplift Resistance
TAS 102(A),
1995:
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049).
TAS 101
P39740.0112
02/21/2012
ATL (TST3782)
Physical Properties
RM624.05-14
07/03/2014
ATL(TST3782)
Physical Properties
RT0624.04-14
07/07/2014
ATL (TST3782)
Physical Properties
RT1210,02-15
12/17/2015
ATL(TST3782)
Physical,Properties
RT1210.03.15
12/17/2015
ATL (TST3782)
Physical Properties
RT1103.01-15
11/07/2015
ATL (TST3782)
Physical Properties
RT1103.02-15
11/07/2015
ATL(TST 3782)
Physical Properties
RT3103.03-15
11/07/201S
- ATLM3782)
Physical. Properties
RT110104-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT3103.05-15
11/07/2015
Mianii-Oade (CER1592)
HVHZ Compliance
14-0416.2.2
11/27/2014
Miami-Dade(CER1592)
HVHZCompliance
15-0721.04
11/05/2ms
Miami-Dade(CER1592)
HVHZCompliance
16-0112.06
02/25/2016
Miami -Dade (CER1592)
HVHZCamphance
16-0112.07
02/25/2016
Miami-Dade(CER1592)
HVHZCDmpliance
16-I1112.08
02/25/2016
Tile Roof institute
TAS100, TAS 101, 102, 102(A)
Membership Confirmation
Current
PRI(QUA9110)
Quality Assurance
Service Confirmation
Up. 11/02/2o18
Exterior ResearchandDesign, LLG
Evaluation Report E39316.2=2-1-N
Gert%jiraceojautl�or4atrono95P3
ED17ION(2017) FBC HVHZ EVALUA-noN
F1.7800-R1ir
Entegra Roof Tiles
Revision 4:10/17/2017
Page 2 of e
4. PRODUCT DESCRIPTION:
4.1 =='ttnCY'ttica:�$
16,
1-va•
1c•\ /
Y
i 16, —
T-
2-
7
Bermuda Fiat
Horizon Flat
J TRINITY) ERD
Plantation Fiat
Exterior Research and Design, LLC. Evaluation Report E39310.IY11-I-R4
rert,rrote afAtdhorJ mR9sce 6'"EDITION(2017) FBC HVH2 EVAWATION F1.7804-R10
Entegra Roof Tiles Recision 4: 10/17/2017
Page 3 of
4.2
4.3
X.I.
4.3
IT,
Estate "S"
Galena Spanish "V
Exterior Research and Design, LLC
t aefrmm of A"Mer7meuo 09503
Bella High "5"
10"
67Eomm (2017) EBC HVHZ EVALl1AT1oN
Entegra RoofTRes
p 1h t
Hacienda
Regal
Evaluation Report E393101111.1-94
FL7804-R30
Reviiion 4:10/17/2017
Page 4 of 9
TRjNITYj ER©
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitVjERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112,Appendix A'.
5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold current Florida Statewide Product Approval or Local Approval for use in the roof
assemblies in FBC HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule
61G2O3.
6. INSTALLATiON:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall
comply with manufacturers current published instructions, but not Jess than the requirements of RAS 118,
RAS 119 or RAS 120, as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in
accordance with Roofing Application Standard RAS 227-11 using the data outlined herein.
l
i
5 u
Tile
Batten Application
Direct -Deck Application
Bermuda Flat
I 0.189
0.205
' Plantation Flat
0.267
�0.289
Horizon Flat--
0305
0.330
Bella High "S"
_
0.349
I 0.378
Estate "S"
0.267
0.289
Hacienda _
0267
0.289
Galena Spanish "So i
N/A
0.235
Regal
0.287 I
0.313. _ J
; is l.'fi
i .<.. Ir.* cRESTORI,NG.(ttlgiNEfJ�UUETO GRA�fi_tt� M�(Fi
111E}.
cl r. , ,:: _T` � f,.y
Roof Slope (0)
Tile
2:12<0<3:12
3:12<044:12
412<_0<5.12
5:12:5 <6:12
1 6:1240<7:12
9>7:12
Battens
Dhect
Battens
Direct
Battens
Direct
Setters
Direct
Battens
Direct
Battens
Direct
Bermuda Flat
5.22
6.43
5.17
637
5.09
6.27
438
6.15
4.86
6.00
4.72
5.83
Plantation Flat
7.22
7.91
615
7.79
6.75
7.67
6.61
752
6.44
732
6.26
7.04
Horizon
7.60
8.32
7.52
8.24
7.41
8.12
7.26
795
7.09
7.76
6.89
7.55
Bella High "S"
6.19
6.89
6.11
6.80
5.99
6.67
5.85
6.51
5.68
633
550
6.13
Estate "S"
6.14
6.94
5.91
6.74
5.82
6.64
5.70
6.50
5.56
633
5.40
6.14
Hacienda
5.92
6.80
1 5.92
6.80
5.82
6.69
5.70
655
5.56
6.39
5.41
6.22
Galena Spanish"5"
N/A
6.20
N/A
6.13
NJA
6.03
N/A
5.89
N/A
5.74
N/A
5.57
Regal
7.77
8.34
7.77
8.34
1 7.65
1 8.20
7.49
3.03
7.30
7.83
1 7.10
7.61
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4
ClrtiAcate ojAvMaraado. 0950 6'"EDMON (2017) FBC HVHZ EVALUATION FL7804-R30
Entegra Roof Tiles Revision 4: 10/17/2017
Page 5 of 8
W
Ott
H
H
I
m,
m
Of
H
It mP
11I
::Srf.fiYt
ry
H
N
O
OI
I_
N
-M
wH
4
O+
M
NOSm
ei
N
O1
'gym+
m
�^
PZ
r r
m
m
m
v`�i
•+
H
vi
e
m m
m
N
P
I
i
.
g
v
O
In
o
m
P
O
i+I
m j 'R
m
W
:1
ry
u
.qi
v�ni
.rv-i
°'
pn
f
c
O
E
m
�a
a
v
I
tl'i [i
it
Z
Z
W
I�
W
IL
2
Z
2
Z
-E
°
Z
Z
I W
IL
3
3
VI
NNC
N
N
OI
V1
N
N
NO
NOO
NOEO
IOXOE
NEO
L4YOI
0%[
uNO
fi
LlGG
l
S
E
E
E
O
m
O
EE
E
VOI
Z
Z
E I E
e
EEEE
N
N
V1
V1 N
6'
m
Z
Z
S
Ri
c;
c
e
°
3
3
3
3
c;
c
c
° I °'y
;
3
o
� s
O
r
0
0
�-
h
I-
O
F.
o.
o
o
4'
o
3
P
y
e
o
3
e
o
e
o
3
3
3
3
e
O
3
h
r' %
°
=
A
d
r
I
r
»
a
Y
E
3
o
3
J�mSS
1N
10
N
N
N
N
G
G
C
N
N
I
—N I
N10
N
R
h
°
z76V
2
Z
Z
Z
2
Z
Z
2
Z
to
VI
n
mI
tl!,
a
a —
ry LL
Z
is
f`
tL
O
N O
O O
a '8
�
L A
OG
qC
`J TRINITY ED
fttdbe fiemr<E'ategr�ar,R00,�TIfei CLCZ��sF/1¢ per�arfnaaCC`�CQ[dIL�1Y3d !a 70�77C,,4.d(esfiCSed Oa �iC Ye31Y2Cti4P'adpeSrJe madUjdfrLUterY' tCst -.
rppii?traaaMfemrtia,�e.�foAs�BrtepmRoo�tJeR1.iC're17e�u th YdliR"srverCihn ct�retFtaA(nYi�'24Kesevafues�of'ourit♦gw7oa-:
`itti �� 4
m. t�rls`F6�FIUN�" va aa�rors p .� ,(g
., ,� ( fTe brig P ot�tdasrd�� �'1ndhAdi/akadfi sJviY inaapjaci iex�far7rr,(aimNt(<t`r`i pa praduci`o�ipraYa7s-,
lfrytll{yhgsrs,.Teh",siohsargfhermJo�rinq((or��fordeefermr�ilngtN�ndtgadagdgve{tumtn�rq(omeatl3er�oSrera'�' � `�, '
�r�s
Tile Adhesive
j
rile
Product I Product Approval
Placement -
Mf (ft-Ibf)
i
"TILE BOND^'" by Dow Chemical NOA 16-0222.01
4 Interdependent (2-paddy)
41
Bermuda
Flat,
'Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03
Interdependent (2-paddy)
73
Plantation
"Polyset- RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03
Interdependent (2-paddy)
52
Flat or
Horizon
1 I
"Polyset" AH-160" by ICP Adhesives &
NOA 17-0322.03
interdependent (2-paddy)
43
Sealants
independent (medium paddy,-30 g)
Independent (large paddy,-45 g)
51
92
"TILE BOND'"" by Dow Chemical I NOA 16-0222-01
N' Seal Storm Bond" by DAP Foam
Interdependent (2-paddy)
44
i
Ir'Touch
�_NOA 16-0421_03
Interdependent (2-paddy)
42
Estate "5" or
Polyset® RTA-1" by ICP Adhesives & Sealants ____NOA 16-0315.03 _
��
_
Interdependent (2-paddy) __
_
_ qq
Hacienda
°
olysetAH-160" by ICP Adhesives & i
Interdependent (2-paddy)
_ _ 5 0
I
Sealants i NOA 17-0322.03
---^ i
independent (medium paddy, "30 g)
37
Independent (large paddy,-54 g)
61 '
_
Mortar r
____ j Various
"TILE BOND"'" by Dow Chemical ' NOA16 0222.01
Per RAS 120
Interdependent (2-paddy)
21
48
'Touch N' Seal Storm Bond" by DAP foam ( NOA 16-0421.03 1
Interdependent (2-paddy)
52
Bella High
"Polyset® RTA-r 1
"S", Galena
by ICP Adhesives & Sealants NOA 16-0315.03
_�—
Interdependent (2-paddy)
36
I
Spanish "S"
"polysete AH-160" by ICP 1
Interdependent(2-paddy)
30
or Regal
Adhesives &
Sealants 1 NOA 17-0322.03 ;
Independent(medium paddy,-30 g)
49
Independent (large paddy,_-63 g)
94 1
'
Mortar ! Various
Per RAS 120
25 )
LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited quality Assurance
Agency noted herein.
and/or
E "i
[S FR�a�
Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-R4
Qrrr te"/auMorirnaon 0003 6EDMON(2017) FOC HVHZ EVALUATION 1`1.7804•RSO
Entegra Roof Tiles Revision 4:10/17/2017
Page 7 of 8
E
� y l
jf
�. T RINITY j ERD
Labeling: Horizon Flat, Hacienda, Regal
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
aflPes
Okeechobee, FL
Bermuda Flat, Plantation Flat, Estate S Bella High "S", Galena Spanish 'S"
Ft. Myers, FL
Horizon Flat, Hacienda
Deerfield Beach, FL
Horizon Flat, Hacienda, Regal
10. QUAUTYAssuRANCEENTTTy:
PRI Construction Materials Technologies, I.I.C. —QUA9110; (813) 621-5777
- END OF EVALUATION REPORT —
Exterior Research and Design, U.C. Evaluation Report F39310.31.11-1-R4
Cert(/rmteoJA"Moriradonp9503 6'vEDrnoN(2017) FBC HVH2 EVALUATION FL7804-R10
Entegra Roof Tiles Revklon 4: 20/17/2017
Page 8 of 8
NEW I etc.
SCANNED CerOhCnteafAutharization p324SS
BY 353 Christian Street, Unit►t13
St Lucie County Oxford, Cr 06478
(203)262-9245
ENGINEER EVALUATE TEsr CONSULT CEFMFY
ICP Adhesives and Sealants; Inc.
12505 NW 441s Street
Coral Springs, FL33065
(888)774-1419
FL6276-R7
Date of Issuance: 03/21/2006
Revision 7:08/15/2018
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable riles and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 61' Edition (2017) Florida Building Code sections noted herein.
DESCRIPTICIM ICP Adhesives Polyset® RTA-1
LAMLINe: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONnNUED ComPuANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report bythe.named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes
or the referenced Quality Assurance documentation changes. NEMO ETC, LLC requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
AuvEirnsmErvr The Evaluation Report number preceded bythe words "MEMO ETC, LLC Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPEMON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request ofthe Building Official.
This Evaluation Report consists of pages 1 through B.
Prepared by:
y•, aS �rti;i.fi
Robert J.M. Nieminen, P.E. +�;•..;"o;c,�-• me�mmve�aac�aos�savu,a,ruanyaonen
Florida Registration Na. 59166, Florida Dr4 ANE1983 �ti'.`g�w��°'�� elnron%P.E0ne0d/�mOmt��na�azm
CINTIFICATM OF INDEPENaENCE; ,
I. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any Company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing produtts'it evaluates..
3. Robert Nieminen; P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert. Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the
product
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, In any way, the Designer of Record for any
project on which this Evaluation Report or previous versions thereof, is/was used for permitting or design guidance unless retained
specificaliyforthat purpose.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Roof Tile Adhesive
CompfianceStatement: ICP Adhesives'Polyset' BTA-1, as produced by ICP Adhesives and Sealants, Inc., has
demonstrated compliance with the 616 Edition (2017) Florida Building Code through testing in accordance with the
Standards set forth herein. Compliance is subject to the Installation Requirements and Limitations / Conditions of
Usesetforth herein.
Sections s Property Standard year
1504.2.1.1 Overturning resistance SSTD11 1997
CnLnv
Marmnatlon
Reference
Date
ERD (TST6049)
Statkllpllft—ssm 11
E42730.08.13
08/23/2013
ERD-0 ST6049)
Static Uplift —SSTD 11
ECM-SC6795.12.14-2
02/27/2015
Miami -Dade (CER 1592).
HVHZcompiiance
18-013L02
07/12/2018
NEMO(TST6049)
Static Uplift—SSfD 11
4LACP-I8-00Lo5.18-1
05/15/2018
NEMO CMT6049)
Tensile Adhesion/Underlayments
45-1CP-18-601.07.18
07/23/2018
PRI (TST5878)
Static Uprdt—SSTD 11
PFI-006-02-01
05/09/2005
Pill (TST5878)
Static Uplift —SSTD 11
PFt-008-02-03
12/14/2005
PIU(TST5874)
Static Uplift—SSTD 11
PFI-00"2-04
12/14/2005
PRI(TST5878)
Static Uplift— SSTO 11
POP-009-02-05'Sev2
06/01/2015
UL, L1C (QUA9625)
equality Assurance
Service Confirmation
02/07/2018'
4.1 ICP Adhesives,PolgseV RTA-1
mixed canisters.
Pre-
5.1 This is a building. code.evaluat(on. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, In any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof; is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation. Report is not for usein FBC HVHZ jurisdictions.
5.3 Fire classification is not part of this evaluation. Refer to a current Roofing Materials Directory for fire ratings of this
productand FBC 1505.2.
5.4 ICP Adhesives Polyset' RTA-1 can be used with flat; low and high profile tiles or any rigid, discontinuous. roof
assembly having a current Florida Statewide Product Approval or approved on a local -level by the Authority Having
Jurisdiction.
5.5 Underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide Product Approval or
approved on a local -level by the Authority Having Jurisdiction for use with ICP Adhesives PolysW RTA-1.
5.6 Field tiles, meeting the limitations of FBC1609.5.3, using ICP Adhesives Polyset' RTA-1 are limited to projects having
an Aerodynamic Uplift. Moment (Ma), determined in accordance with FBC 160953 or Tables 2Aand 28 of'FRSA/TRI
April 2012 (04-12), not greater than the,following Allowable Overturning Moment values. Refer to Section 10 and
ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy Placement details.
�t
NEW ETC, LLC
Centif[mteafAethodudidn A32455 W8 EDITION(ZD17) FBC NON-HVHZ EVALUATION
ICP Adhesives PoI*t' RTA-%(1i88) 774.1419
Evaluation Report0276R.02A6-R7
FL6276-R7
Revision 7[ 08/15/2018
Page 2 of 8
l 1•
ICE..
Adhesive Paddy Placement
7TypeProfile
Allowable
Pad Size[CantaGArea
PaSection10
Overturning
Moment
(ft4bQ
Interdependent Two Paddy; two (2) ribbons, 11 grams each
Clay
Fiat Low:
install toe and ensure 8-10 square Inch contact area to underside of tile.
Concrete
Ensure.adhesive is making.10 square inch contact area at the tile head lap
Ali
50
area
Interdependent Two Paddy; two (2) ribbons, 11 grams each
Concrete
Medium
Install the and ensure 6-8 square inch contact area to underside of tile. Ensure
S2
44
adhesive is making 10 square Inch contact area at the tilehead lap area.
Clay
High
Interdependent Two Paddy; two (2) ribbons
•' 22 grams tail -to substrate
36
• 11 grams at head -lap
Install tile and ensure 12-16 square Inch contact area to underside, of tile.
#3
-Concrete
High
Ensure adhesive is making 18 square inch contact areaat the tile head lap
area.
33
-
Pan Tileto Undedavment Two (2) ^7-inch long x'6 gram oblbngshaped
beads on underiayment, side -by -side, where the center of the pan tile
contacts the deck starting ^2 to 34 ches from the eave end of the:pan the
.Cap & Pan
Cap Tile to Pan Tile: one (1) ^74nch long x -6 gram oblong shaped bead at
Clay
(Barrel)'
each long edge of the cap tile, Y• to 1-inch from each edge, starting -2 to 3-
94
162
inchesfromthe eave end wor(dngtowards:theridge. Turn cap tile overand
Install onto pan, butting the second. course pan the eave endon
underlayment side -by -side, where the center of the pantile contacts the
deck starting "2 to 3-inches from the eave end of the pan tile.
5.6.1 Data in Table 1 relates to installation over a'30/90' underlayment system, as detailed in the FRSA/TRI April 2022 (04-
12). Alternate underlayment systems include those having a current Florida Statewide Product Approval and/or
approved on a IocaNevel by the Authority Having Jurisdiction specifically for use with ICP Adhesives PolysetO RTA-1.
5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with ICP
Adhesives Polysete RTA-1 shall be tested in accordance with SSTD 11 or Testing Application Standard TAS 161. For
the interdependent multi -paddy method, an additional Z to-l.margin of safety above that specified in SSTD 11 or
Testing Application Standard TAS 101 shall be applied in determining the 'allowable overturning moment'..
.5.7 Hip and ridge tiles using ICP Adhesives Polifsee RTA-1 are limited to projects having hip/ridge design pressure
requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the
following values. Refer to ICP Adhesives and Sealants, Inc. published installation instructions for Adhesive Paddy
Placement details.
NEMO Erc, LLC
Cnfifirate a/Authmmrhan 032455 ba' EDITION 12017) FBC NON-HVH2 EVALUATION
ICP.Adheslves Polyset• RTA-1, (888) 774-1419
Evaluation Report 02768.02A6-R7
FL62766R7
Revistan 7.08/15/2018
Page3 of 8
Y _-__—^_i RSA/TRI April 2012
esrves o yset an e.tile roof'assem 1 shall be installed in acwrdance wi4h F
(04-12) and ICP Adhesives and Sealants, Inc published installation instructions, subject to the limitations outlined in
Section S.
6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12).
Proprietary hip and.ridge metal shall be installed in accordance with the manufacturer's Florida ProductApproval.
6.3 Installation shall be performed by applicators that hold a valid Qualified Applicator Card presented by ICP Adhesives
and Sealants, Inc.
6.4 All tiles must be set in adhesive prior to tack free time (approximately 2 to 3 minutes).
the Building Official or Authority
.ww.A I CfURGiNTiS+Sk:'e
I.I.C. -
NEMO ETC, LLC
Ontifknteo/AuthadartlanOM456 6"'EDITION(2017) FSCNON•nVHZ EVALUATION
ICP Adhesives Polyset* RTA-1; t888) 774-1419.
Evaluation ReportOZ768.0286-R7
FL6276-R7
Revision 7c 00/1312018
Page 4 of 8
10.7 I Detail #Z: Low/Medium Profile Tile:
Eave Course Line
Eave Cbslue
t ,
i
NEMO ETC, LLC
4rtfimte of Audidwaatfnn MM
PanotTi
6'" EDITION 12017) FeC NON-HVHZ EVALUATION
ICP Adhesives PoIrW RTA-1, (888) 7/41419
Start Save CoursePaddrc3
at Tile Catuse Line
Evaluation Report 02768.02A6-R7
FL6276-R7
Revision 7.. 08/15/Z018
Page 5 of
r }�
E
,
10.3
10.4 1 Detai184: Two Piece Barrel (Cap & Pan) Tile:
NEMO ETC, LLC Evalwtion Report 02768AL06-R7
CeNlfwtenfAvthaf& wonN32M 6r"EDMON(20171 FBC NON•HVHZ EVALUATION PI627&R7
ICP Adhe&ft PolyseN RrA-:4 (888( 774-1419 Revision 7: 08/Z/2018
Page 6 of 8
10:5 1 Detail N5:
20.6
w(th screw):
Adhere -starter
tileav'dh-a•2!`-A-7"-
Paddy-placed3"
dowmfrom-head-
of•tile4
NEMO ETC, LLC
OSGf� ofAotbMft WRM455 fiat EOIPON(2017)FOC NON-HVHZ EVALUAMGN
ICP Adhesives PolysW R7A-1; (888) 774-1419
fONEMOjetC.
V-X-W'-Bead•of lCP-
Adhesives•
PolysetORTA=1•mc f-
tile-adhesive-I
#10x•2-1j2"SOrew-
Code•Approved
Fastenerjj
EValu3UOn Report 02768.02.0647
FL6276-R7
Revision 7: 08115/201R
Pagel of 9
'^l
10:7 Detail R7: Hip and
7" Oblong Paddy
END OF EVALUATION REPORT-
NEMO ETC,.LLC
tbdJjmte of AuthmbutbRA3245S 0EDITION i20D) FSC NON-HVH2 EVALUATION
ICP Adheslvw PolyseN RFA.1, (888) 774-1419
7" Oblong Paddy
Evaluation Report02M.07-06•R7
FL6276-R7
Revision 7108/LS/2018
Page got 8
RECEIVED
MAY 0 9 2019
ST. Lucie County, Permitting
NEORECta.
CerU/kate ofAuthorizaaon g3Y455
353 Christian Street, Unit f113
Oxford, CT 06478
(203)262-9245
ENdiNEFA EVALUATE TEST CONSULT CERTIFY
e •o•
Boral Roofing Evaluation Report M35710.12.10-Rl
7575 Irvine Center Drive, Suite 100 FL14317-RIO
SCANNED
Irvine, CA. 92618 Date of Issuance:12/21/2010
(602) 269-2288 BY Revision 11.10/12/2018
SCOPE: St. Lucie County
This Evaluation. Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product underthe Florida Building Code and Florida Building: Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6u' Edition (2017) Florida Building Code sections noted.
herein.
DFSCRIDnON: Boral Roof underlaymems
LABELING: Labeling shall be In accordance with the requirements of the Accredited QualityAssurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid. until such time as the narked product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreementto notify Robert Nieminen, P.E: of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADvEansEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
iNsPEcnoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:--
41.�...`�/ik '
9-1
Robert J.M. Nleminen, P.E.
`+.f,�,�jS?`
mefaahmleseal appearingwasauthanud by aobert
Florida Registration No. 59166, Honda DrAANE1983
P.Ean10/1WG*. Thismesnotsmwim
' eleCmnlmliysisned daounent
CEarincomoNOFINDEPENDExce
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest In any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products It evaluates.
3. Robert. Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluationreports are being.issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,. P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/eras used for permitting or design guidance unless retained
specifically for that purpose.
fONEMOjetc.
ROOFING COMPONENT EVALUATION:
Sub -Category: Underlayment
Compliance Statement: Boral Roof Underiayments, as marketed by Boras Roofing, have demonstrated
compliance with the following sections of the 0 Edition (2017) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the installation Requirements and Limitations
J Conditions of Use set forth herein.
section
Property
Standard
Year
1504.3.1
Wind Uplift
UL 1897
2012
1507.1.1, T1507S.1;
Physical Properties
ASTM D1970
2015-
1507.2.9.2
1507.9.3
Physical properties
FRSA/TR1April 2012 (04-12)
2012
.Entity
Examination:
Reference
Date
ERD (TST 6049)
Physical Properties
M36790.07.11
09/30/2011
ERD (TST 6049)
Physical Properties
840380.08.12
08/2812012
ERD (TST 6049)
Tensile Adhesion J LTA
C4142(L09.12-2
09/11/2012
ERD UST 6049)
Adhesion
841940.09.12
09/13/2M2
ERD (TST 6049)
Tensile Adhesion / LTA
B47390:07.14-1
07131/2014
ERD (TST 6049)
Tensile Adhesion / LTA
B47390.09.14
09/04/2014
OC(PDM1838)
Physical Properties
Equivalencystateinent
11/02/2017
PRI (TST 5878)
ASTM D2970
NEI-031-02-02:REV
10/27/2010
PRI (TST5878)
ASTM D1970
NEI.029-02-01:REV
12/03/2010
PRI (TST 5878)
Tensile Adhesion/LTA
NEI-046-02-01REV
12/17/2010
'PRI(TST 5878)
FRSA/TRI April 2012
NEI-676-02-01
02/14/2011
PRi (TST 5878)
ASTM D1970
NEI-034-02-02
M/29/2013
PRI (TST5878)
Wind Uplift
BORR-061-62-01
03/17/2015
PRI (TSTS878)
Wind Uplift
BORR-0O5-02-01
06124/2015
PRI (TST 5878)
Tensile Adhesion / LTA
DAPF-002-02-01
03/08/2018
PRI (TST 9878)
ASTM D797Q (adhesion)
OCF-443-02-01
10/11/2018
UL. LLC.(QUA .9625)
QualityAssurance
Service Confirmation
Exp.08/21/2020
4.1 SaraP TileSeal SD"r is a nominal 50-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meetsASTM D197d.
4.2 Swale TileSeal"T is a nominal 6D-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI04-12.
49 RoralO MetalSeal"r Is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI04-12.
4.4 GatorSeal" is a nominal55-mil thick, granular surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roof underlayment; meets ASTM D1970.
45 Citadel" Plus is a nominal 48-miithick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roofing underlayment for use as abase -layer in multi -ply underlayment systems-, meets ASTM D1970.
NEMO ETC, LLC Evaluation Report M35710.12.10-R11
CS'ra7=ieafAuah atara3245S WK EDITION 12017JFBC NON-HVHZ.EVALUATION FL14317-R30
Boral Roof Underlayments; (602) 2694M Revision 11. 10/17/2018
Paire.2of 8
ONEW10jeft.
5.1 This is a building code evaluation. Neither NEW ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for aoYproject on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product
5.4 - Boral Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with suppordngdata for the prepared roof covering.
S.S. Allowable Roof Covers: Table 1 pertains to use of each listed undedayment bv-itself beneath the stated roof
covers. Referto the installation instructions for multi -ply un.derlayment options
UnTI Vincent
Asphalt
Nail -On Tile
Adhesive -set
Metal
Wood Shakes
Slate
Shingles
Tile
& Shingles
Boral TileSeal Soar
Yes
No
No
Yes
Yes
Yes
Borallileseal'n
Yes
Yes
Yes
Yes
Yes
Yes
(See 55.1)
Boral Metalsealw
Yes
Yes
Yes
Yes
Yes
Yes -
(See 5.5.1)
GatorSeal
Yes
No
No
No
Yes
Yes
5.5.1 "Adhesive -set Tile" is limited to use of following Approved tile adhesives / undedavment combinations_
Adhesive
7Polyuretha.ne
Florida Product
Approval
Underlayments
al StbrmBood Roof Tile Adhesive
FL14506
Boral TileSealw or Borai MetaLSeaIw
al StonnBond 2Two.Coihporient
Adhesive
r{21374
Boral TfleSeal"r or Boral MetalSeal"r
Dow TILE BOND'" Roof Tile Adhesive
FL22525
Boral TBeSealwor Boral MetalSeaPR
ICP Adhesives Polymer° AH-16D
FL6332
Boral TlleSealvr or Boral Meta)Sealw
ICP Adhesives Polyset' RTA-1
FL6276
Boral TdeSealwor Boral MetalSealar
..� 1 Referto Tile MonufacturersnrAdhesNe Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
..., f NEMo ETC, LLC Evaluation Report M35710.12.10-R31
Ce,hftwMofAuthorirotion#32455 0 EDITION (2017) FBCNON•HVHZ EVALUATION FL14317•R10
Boril Roof Undedaymenut (602) 269.220 Revision 11: 10/12/2018
Page 3 of
ONEMOletc.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
i Citadel Plus, Boral TileSealSo ; Boral' ileSeal" ; Borai MetalSealRr or GatorSeal:
➢ Plywood (unprimed or primed with ASTM D41 primer).
Boral TileSeal"T or Boral MetalSeal"r:
➢ OSB (unprimed or primed with ASTM D41 primer).
Note: Refer to Section 5.6.4 for uplFft limitations associated with direct -deck underlayment installations where the
overlying roof cover is odhesive-set tile roofing
5.6.2 Bond to Base Laver Underigniment:
Citadel Plus, Boral TileSeall SOn Boral TileSeal"r, Boral MetalSeal"I or GatorSeal:
➢ ASTM D226, Type 11 felt Citadel Plus.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For Installations under adhesive-settilesystems, base layer shall beattached per minimum
requirements of.FRSA/TRI April 9012 (04-12), Appendix A, Table i, or as listed in Section 5.6.4 herein, or as tested
in accordance with FBC 1504.3A.
5.6.3 Bond to Other Substrate Types:
Citadel Plus; Boral TileSeal 5011; Boral TileSeaF, Boral MeitalSeal"r or GatorSeal:
D ASTM D41 primed metal (e:g., flashing metal; valley metal, etc).
Boral TfleSeal"r:
➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's. Product Approval.
5.6.4 Wind Resistance for Underlavment Systems in Adhesive -set TileApplications: FRSA/TRLApril 2012 (04-12) does
not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the
underlayment forms part of the load -path. The following wind uplift limitations apply to underlaymentsystems
that are not addressed In FRSA/TRI April -2012 (04-12) and are used in adhesive -set tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer
to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure =-120.0 oast:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer. (Optional) ASTM D41 to the plywood deck
Base Ply: Citadel Plus, self -adhered
Cap Sheet: BorafTileSeal"T or Boral MetalSealn self -adhered, and back -nailed within the selvedge -edge side laps
using 12 ga; x 1YV ring shank nails through 32 ga.,1-5/ir diameter tin caps spaced 1271nch o.c
#2 Maximum Design Pressure =-1425osf•
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply; None
Cap Sheet: Boral TileSeallnor Boral Nletal5eal"T, self -adhered and back -nailed within theselvedge-edge side laps
using 12 ga. x IN" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
NEMO ETC, LLC
Evaluation Repoli M35730.1210-R71
renif¢vte ofAuthor¢o6'o41132413 6n EDMON (2017) FSC NON.4iVHZ EVALUATION FL14317•RlG
Boral Roof Underlaymeotr (6021269.2288 Revision 3L 10/12MIS
Page4 of 8
l
#3 Maximum Design Pressure=-202.5 psF fONEMO[eft.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply: None
Cap Sheet: BoralTile5eal"rorBoral MetalSeal"r,self-adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 13C ring shank nails through 32 ga, 1-5/e diameter tin raps spaced 12-inch o.c.
#4 Maximum Design Pressure =-210 0 osf:
Deck: Min. 15pVnch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer. KARNAK #895ta Tak Primer to the plywood deck.
Base Ply: None
Cap Sheet: Boral TileSealinorBoral MetalSeal"r,selfadhered,and back -nailed within the selvedge -edge side laps
using 12 ga. x 134" ring shank nails through 32 ga.,1-5/e diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure-1200
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer. ASTM D41 to the concrete deck
Base Ply: (Optional) Citadel Plus, self -adhered
Cap Sheet: Boral TfIeSeal"Tor Boral MetalSeal" , self -adhered
5:6.4.1 Note: For adhesive-settile systems, if there isabase ply ormid-ply of Citadel Plusin the system, the project design
pressure requirements may not exceed -120 psE
5.7 Exposure Umitations:
GatorSeal shall not be left exposed for longer than 30-days after installation, prior to placement of final roof cover.
Boral Tileseal So" Boral TileSealw or Boral MetalSeall r shall not be left exposed for longer than 180-days after
installation, prior to placement of final roof cover.
Citadel Plus, for use as a base -layer in a.multf-ply underlayment system, shall not be left exposed for longer than
180-days after installation, prior to placement of subsequent underlayment layer.
5.8 Tile Slippage Limitations [FRS /TRI April2012 (04-1211`
When loading roof tiles onthe underlayment in direct -deck file assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens durine loading of the roof tiles
* g &, +TAB : TILE,SLiPp G Lity -DEC LEifam.M U " aa'
:a�.a%
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions
subjectto the Limitations set forth in Section 5 herein and the specifics noted below.
6:2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to` application, and prime the substrate (if applicable).
6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40'17 and rising.
NEMO ETC, LLC
Ce'VT=eofAuftr*adan naMs V'EDmON(2017)FBC NON-HVHI EVALUATION
Boral Roof Underlaymentr (602) 269-2288
Evaluation Report M3571o.t210-R11
FL14317-R30
Revlsron 11:10f12/2018
Page 5 of 8
ONEMOletc.
6a Citadel Pius•.
6.4.1 Citadel Plusislimited to use as a base or mid -layer in multi -ply underlayment systems beneath Boral TleSeal SO"T,
Boral Tleseal'n or Gatorseal.
6.4.2 Slope limitations are those associated with the top -layer underlayment
114.3 DirecttoDeck:
Cut the membrane into manageable lengths, typically SO to 12 ft. Align the membrane parallel to the roof edge,
extending over by x-inch. Fold the membrane away from the edge onto itself. Remove the release sheet Place
the membrane with the exposed rubberized asphalt onto the deck pressing firmly into place. Roll into place with
a weighted roller.
Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch
diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width ofthe
black -selvedge area, minimum 2 inches (horizontal lap) and minimum 6"end (vertical) laps.
Install final underlayment layer atop Citadel Plus per'direct-to-decle instructions for Boral Tileseal 50" ; Boral.
TileSeal" ; Boral Meta1SeaP'r or GatorSeal.
6.4.4 To Base Sheet:
Install base sheet of ASTM D226, Type II felt in accordance with Code requirements or install base ply of Citadel
Plus in accordance with Boral Roofing published installation instructions and section 6.4.3 and when used as part
of a multi-plysystem.
Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and
Section 6.4.3.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TleSeal SO"T, Boral
TleSeaF or Gatorseal.
Note: For adhesive -set the systems, if there is a base ply or mld=ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
6.5 BoralTileSea150f'r.
6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1,3 for
the type of prepared roof covering to be.installed.
6.5.2 Do not use Boral TileSeal 5011T on roof pitches less than 2:12.
6.5.3 Nort Tile Applications. Direct to Deck*
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over byY.4rich. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the memtiranewith the exposed rubberized asphaltonto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails& tin -tags or 1-inch diameter
plastic or steel cap nails spaced maximum 244nch o.c. for slopes below 7:12 and maximum 12-inch o.c. for slopes
7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch.
Seat under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam
method detailed in Boral Roofing published installation instructions.
NEIVfO ETC, LLC Bialoation Report M3571012:10-RU
kenifiwteoTAutbairodon M32655 V" EDmOPlt2017) FBC NON•HVHZ EVAWAnoN FL143174UO
Boral RoofUndedaymentsl ISM 269-MU Revision 11: 10/12/2018
Page 6 of 8
6.5.4 Non-TileAoblications. to Base Sheet ONEMOjetc.
hLstall ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal50Hr in accordance over ASTM D226, Type If felt or Citadel Plus with Boral Roofing published
installation instructions and Section_6.5.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.6 GatorSeal•
6.6:1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBCTable 1507.1.1 for
the type of prepared roof covering to be installed:
6.6.2 Do not use GatorSeal on roof pitches less than 2:12.
6.6.3 Non -Tile applications. Direct to Deck.
Cut the membrane into manageable lengths, typically 10 to 12 ft, Align the membrane parallel to the roof edge,
extending over by 94rich: Fold the membrane away from the edge onto Itself. Remove the release sheet: Place
the membrane with the exposed rubberized asphalt onto the dedc, pressingfrm)y into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the Beckwith corrosion resistant roofing nails, nails & tin -tags or 1-Inch diameter
plastic or steel cap nails spaced 244nch o.c. for slopes below 7:12 and'12-inch o.c. for slopes 7:12 and greater.
Overlap successive courses the entire Width of the black -selvedge area, minimum 3-inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -adhering
bituminous underside.)s in contact with the granular or minera(top surface, rolling the interface into place with a
weighted roller, or using the Inverted. Sheet Seam detailed in Boral Roofing published installation instructions.
6.6-4 Non -Tile Applications: to Base Sheet,
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install GatorSealbverASTM D226, Type li felt or Citadel Plus in accordance with Boral Roofing published installation
Instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the :granulartopsurface, rolling the interface into place with a weighted roller.
6.7 Boral TileSealiiTorBoral MetalSeal"r:
6.7.1 Shall be installed in with the requirements for ASTM D1570 underlayment in FBC Table 15t17.L1 for
the type of prepared roof covering to be installed.
6.7,2 Do not use Boral TileSeal"T or Boral MetalSeal"T on roof pitches less than 2:12.
6.7.3 Non -rile Direct to Deck:
For OSB substrate, prime. with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into
manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by Y,-inch.
Fold the membrane away from the edge onto itself. Remove the release sheet. 'Place the membrane with the
exposed rubberized asphalt onto the deck, pressing firmly into place: Roll into place with a weighted roller.
Fasten the black selvedge edge tothe deck with roofing nails, nails & tin -tags or 1-inth diameter plastic or steel
cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black -selvedge area,
minimum 3-inch.
Seal under all end (vertical) laps using approved mastic or use inverted Sheet Seam method detailed in Boral
Roofing published installation instructions.
NEMO ETC, LLC Evaluation Report M35710.I210-1111
Cere7koteofAudwtkaean 932455 6'"EDITION (2017)F8C NON-HVHZ EVALUATION FL14317-R10
B6ral Roof Underlayrnents71602) Z69-2288 Revision 12: 20/12/2018
Page 7 of 8
NNEMOJetC.
6.7.4 Non -Tile Applications, to Base Sheet;
Install ASTM D226, Type it felt in accordance with Code requirements or install Citadel Pius in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TleSealw or Boral MetalSeal"I over ASTM D226, Type II felt or Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.7.3,.except end (vertical) laps, described below.
Apply SB5 Mastic underall end (Vertical) laps or otherlaps where the self -adhering bituminous underside Is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.75 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table i herein, using the instructions
noted above as a guideline.
For mechanically fastened tile rooting over 2-plysystem, consisting of Base Sheet and self -adhering top sheet(s),
Base sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table L
For adhesive -set tile applications, refer to Section 5.6.4 herein.
Note: Far adhesive -set the systems,.if there Is a base ply or mid -ply of Citadel Plus in thesystem, the project design
pressure requirements may not exceed -120 psf.
Refer to Section S.8 for tile staging limitations. Battens must be usedfor all tile installations atop Boral TileSeal"T
or Boral MetalSealw with roof pitches of 2%to less than 3:12. Boral Roofing's Elevated Batten System or counter
battens are required.
As required 1
this product
UL, I.I.C. — QUA9625; (631)
MEMO ETC, Lu:
Ceio%tareofAaft, Oban#32455
Official or Authority Having Jurisdiction in order to properly evaluate the installation of
- END OF EVALUATION REPORT -
6- EDITION (2017) FBC NON-HVHZ EVALUATION
Boral Rddf UndeilayMntr, (602)269-2M
Evaluatian Repoli M35710.]2:10-R31
FL14317-RID
Revision SL 30/]Z/Z018
Page 8 of 8