HomeMy WebLinkAboutNOAMiAM
WINN MIAMA-➢ADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION IvItami; Florida33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) ivww,miamidai e.e rv/ceonomv
Polyglass USA Inc. SCANNED
1111 W: Newport Center Drive BY
Deerfield Beach, FL 33442 St. Lucie County
SCOPE:
This NOA is. being issued under the applicable rules and regulations governing the use of construction materials. The
documentation -submitted has been reviewed and accepted by Miami -Dade County REP: - Product Control Section to be
used in Miami -Dade County and other areas. where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes_ If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
it it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County. Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION ofthis NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
ofthis NOA shall be cause for termination and removal ofNOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shallbe available furipspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.14-0717.08 and consists of pages 1 through 8.
The submitted documentation was reviewed by Gaspar J Rodriguez
r9ArswAOe carmrarmr NOA No.: 15-0410.04
r+ Expiration Date: 09/13r11
Approval Date: 08/I1/16
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category Roofing
Sub -Category: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Product Dimensions
Polystick IR-Xe 65' x 31-1/s"
Manufacturing Or 65' x 3'
Location #1 & #2 60 mils thick
Polystick Dual Pro 6l' x 3'3 /s"
Manufacturing 60 mils thick
Location #2
Polystick Tile Pro 61' x 3'3 '/s"
Manufacturing 60 mils thick
Location#2
Test
Specification
Product
Description
ASTM D 1970 A fine granular/sand top surface self -adhering, APP
polymer modified, fiberglass reinforced, bituminous
sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice & rain shield.
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
ASTM D 1970 reinforced waterproofing membrane. Designed as a
metal roofing and roof tile underlayment.
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
roofing and roof tile underlaymem.
Polystick TU Max
65'8" x 3 3-3/8"
TAS 103 and A rubberized asphalt self-adhering.polyester reinforced
yfpnufacturing
60 mils thick
ASTM D 1970 waterproofing membrane. Designed as a a roof tile
Location #1 & #2
underlayment.
Polystick TU P
32'10" x 3")-Va"
TAS 103 and A rubberized asphalt waterproofing membrane, glass -
Manufacturing
130 mils thick
ASTM D 1970 fiber/polyester reinforced, with a granular surface
Location #2
designed for use as a tile roof underlayment.
Polystick TU Plus
65' x 3 3 3/s"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
(Surface Printing)
80 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Manufacturing
roofing and roof tile underlayment.
Location #i & #2
Polystick NITS
65'8" x 3'3?/s"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Polystick MTS Plus
65'8" x 3'3-,/s"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Elastoflex S6 G
32'10" x 3'3 1/s"
TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing
ASTM D 6164 with a sanded back face and a granule top surface. For
Location #2
use in roof tile underlayment systems.
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 2 of 8
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Aeencv
Test Identifier
Test Name/Report
Date
Trinity ERD
P10870.09.08-R1
TAS 103
12/04/08
P10870.04.09
TAS I03/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.03.11
TAS 103
03/02/11
P33370.04.11
ASTM D 1623
04/26/11
P36900.09.11
TAS 103/ASTM D4798 & G155
09/01/11
P37300.10.11
TAS 110/ASTM D4798 & D1970
10/19111
P40390.08.12-2
ASTM D 1623
08/07/12
P37590.07.13-1
ASTM D6164
07/02/13
P45270.05.14
TAS 103, TAS 110 & ASTM D1623
05/12/14
P46520.10.14
ASTM D1623
10/03/14
P44360.10.14
TAS 103 & TAS 110
10/07/14
P43290.10.14
ASTM D 1970 & TAS 110
10/17/14
PLYG-SC10130.06.16-3
TAS 103 & TAS I10
06/27/16
PLYG-10130.06.16-1
ASTM D1970 & TAS 110
06/27/16
PRI Asphalt Technologies
PUSA-035-02-01
TAS 103
09/29/06
PUSA-055-02-02
TAS 103
12/10/07
PUSA-089-02-01
TAS 103/ASTM D4798 & G155
07/06/09
Momentum Technologies, Inc.
JX20H7A
TAS 103/ASTM D4798 & G155
04/01/08
RX14E8A
TAS 103/ASTM D4798 & GI55
11/09/09
DX23D8B
TAS 103/ASTM .D4798 & G155
02/18/10
DX23D8A
TAS 103/ASTM D4798 & G155
02/18/10
LABELING:
1. All -membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
4ammirgMIAMFDADE COUNTY
...fr
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19132" plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick
TU P, Polystick TU Plus, Polystick MTS or Polystick MTS Plus, self -adhered.
Surfacing. See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered
AnchorBase Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626.
Fastening: Per FBC 15182 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Elastoflex S6 G, hot asphalt applied
Surfacing: See GeneralLimitations Below.
Deck Type 1: Wood, non -insulated
Deck. Description: Min. 19132" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
AnchorBase Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c, at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6" vertical
laps.
Membrane: Polystick TU Plus, self -adhered.
Surfacing: See General Limitations Below.
NOA No.. 15-0410.04
ruaamaEe unrrr Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3-%" and end laps
shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of
the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building
code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention
to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
S. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick Dual Pro, Polystick Tile Pro, Polystick TU Plus, Polystick MTS and Polystick MTS Pius may be
used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof the systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastotlex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall be applied to a smooth, clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU
Plus, Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Ex sure Limitations
ays
MTS
IR Xe
Elastoilex
S6 G
TU
Plus
TU P
Tile Pro
0 Max
MTS Plus
Winter Haven, FL
180
90
180
180
ISO
180
ISO180
7'.
] So
Hazelton, PA
N/A
90
N/A
l80
NIA
N/A
180
N/A
pr+aaSiiA�rBCr3E1Fi39. NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 5 of 8
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof riles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro, Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof file applications.
Polystick Dual Pro is limited to mechanically fastened roof file applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment.for (direct -to -deck) file assemblies, the maximum roof slope
shall be as follows: (See Table Below)
Tile Profile
Polystick MTS
Elastoflex
Polystick TU Plus, TU P,
Polystick
Polystick
S6 G
Tile Pro, Dual Pro
TU Max
MTS Plus
Flat Tile
Prohibited
4.12
6:12
6:12
5:12
without battens
Profiled Tile
Prohibited
4:12
6:12
6:12
4:12
without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
rile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for
all underlayments except Polystick MTS which shall be loaded onto battens.
NOA No-- 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU
Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe, Polystick Dual Pro,
Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick Dual Pro, Polystick Tile Pro, Polystick TU Max, Polystick TU P, Polystick
TU Plus, Polystick MTS, Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, I 1 gauge ring shank type, applied with a minimum I V metal disk as
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seat lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading rile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations 99 and # 10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes ofTYI2" or greater. It is suggested that on pitch/slopes in excess of 6 YVII2", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
WetlDry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
nsapxtresngccwwr NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 7 of 8
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 Ibs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 8944563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 8 of 8
1-96s - 0.237
SCANNED F
-� BY
rtlarlalaa St. Lucie County
a
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOAI
Boral Rooting, LLC
7575Irvine Center Drive, Suite 100
Irvine, CA 92618
MAY 0 9 2019
-DADS COUNTY
ST. Lucie County NTROLSEC 11ON
26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
FOR
ST. LUCIE C®UNITY
SCOPE: //�'���++
This NOA is being issued under the applicable rules and regulations governing thBe �78tE'onstruction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date -stated below. The'Miami-Dade.County Product Control Section (in
Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incurthe expense of.such testing and the AHJ may immediately revoke, modi fy, or suspend the use of
such product or material within theirjurisdiction. RER reserves the right to revoke this acceptance, ifit is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code,
DESCRIPTION: Estate "S" Tile
LABELING: Each unit shall bear a permanent label with the manufacturees name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be. considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product
TERMINATION of this NOA will occur after the expiration date.or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall he cause for termination and removal ofNOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, .Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy ofthis entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 16-0112.08 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy Semino
�s NOA No.18-0829.03
MIJUIMADECOUN7'r
Expiration Date: 0823/21
Approval Date: 10/11/18
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Boral Estate "S" Concrete Roof Tile, as manufactured by Boral Roofing, LLC in
Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building
Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by
applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127
using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Dimensions
Test
Product
Applicant
Specifications
Description
Boral Estate `S' Roof Tile Length = 16-1/2"
TAS 112
Low profile, interlocking, extruded
Width = I""
Type I b
concrete roof tile equipped with two nail
Class III
hole and double roll ribs. For direct deck
or battened nail -on, mortar or adhesive
set applications.
Trim Pieces 1= varies
TAS 112
Accessory trim concrete roof pieces for
w = varies
use at hips, rakes, ridges and valley
varying thickness
terminations. Manufactured for each the
profile.
2.1 MANUFACTURING LOCATION
1. Okeechobee, FL
2.2 PRODUCTS MANUFACTURED BY OTHERS
Product Name
ICP Adhesives Polyse& AH-160
TILE BONDI Roof Tile Adhesive
DAP Foam Touch N Seal
StormBond$ 2 Roof Tile Adhesive
AM YED
Product Description
Two component polyurethane
foam adhesive.
Single component polyurethane
foam roof tile adhesive.
Two component polyurethane
foam adhesive.
Manufacturer
(With Current NOA)
ICP Adhesives and Sealants, Inc.
The Dow Chemical Company
Dap Foam, Inc.
NOA No.18-0829.03
Expiration Date: 08/23t21
Approval Date:10/11/18
Page 2 of 7
2.3 EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Reuort
Date
Redland Technologies
7161-03
PA 102
Dec. 1991
7161-03
PA 102(A)
Dec. 1991
7161-03
PA 108
Dec. 1991
P0402
Withdrawal Resistance Testing of
Sept. 1993
screw vs. smooth shank nails
P0631-01
PA 108
July 1994
Letter Dated Aug. 1,
PA 108
Aug. 1994
1994
Professional Service Industries, Inc.
224-47099
PA 112
Sept. 1994
The Center for Applied
94-060B
PA 101
March, 1994
Engineering, Inc.
94-084
PA 101
May 1994
25-7094-1
PA 102
Oct. 1994
25-7094-7
PA 102
Oct. 1994
25-7094-4
PA 102
Oct.. 1994
Project No. 307025
PA 100
Oct. 1994
Test #MDC-76
25-7183-1
PA 102
Feb. 1995
25-7183-2
PA 102
Feb. 1995
25-72I4-2
PA 102
March, 1995
25-7214-6
PA 102
March, 1995
Celotex Corporation Testing Services
529454-2-1
PA 101
Sep. 1998
520109-2
Dec. 1998
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplier
March 1999
IBA Consultants, Inc.
2381-264
TAS 112
01/08/08
American Test Lab of South Florida
RT 1210.03-15
TAS 112
12/17/15
PRI Construction Material
DAPF-004-02-05
TAS 101
07/26/18
Technologies
DAPF-004-02-07
Static Uplift Resistance
07/26/18
(Adhesive Set)
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may
required, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix 'A'. Such testing shall he submitted to the Miami -Dade Product
Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
NOA No.18-0829.03
Expiration Date: 0823/21
Approval Date: 10/11/18
Page 3 of 7
3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
4. INSTALLATION
4.1 Boral Estate "S" Concrete Roof Tile and its components shall be installed in strict compliance with Miami
Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations.
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (lb!)
Length-[ (ft.)
Width w (ft.)
Boral Estate 'S' Roof Tile
10.0
1.375
1.08
Table 2: Aerodynamic Multipliers - X (ft)
Tile
Profile
2, (ft3)
Batten Application
I (ft3)
Direct Deck Application
Boral Estate 'S' Roof Tile
0.267
0.289
Table 3: Restoring Moments due to Gravity - M9 (ft. Ibf)
Tile
Profile
3":12"
4":12"
5":17
6":12"
Greater than
7":12"
Boras Estate'S'
Roof Tile
Battens
Direct
I Deck
Battens
I
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
5.91
1 6.74 1
5.82
6.64
1 5.70
6.50
5.56
6.33
5.40
1 6.14
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Nail -On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" plywood) I (min.19/32" plywood)
I'S' Roof Tile I 1-10d
z-iva Smootn or Screw 16.4 21.9 7.1
Shank Nails
1-10d Smooth or Screw
24.3
24.3
24.2
Shank Nail Field Cii a
1-10d Smooth or Screw
19.0
19.0
22.1
Shank Nail Eave Cli z
2-10d Smooth or Screw
35.5
35.5
34.8
Shank Nails Field Clip)
2-10d Smooth or Screw
31.9
31.9
32.2
Shank Nails (Eave Clio)
NOA No. 18-0829.03
Expiration Date: 08/2321
Approval Date: 10/11/18
Page 4 of 7
Table 6: Attachment Resistance Expressed as a Moment Mt (ft-Ibf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Boras Estate'S' Roof Tile I
Adhesive3
3 See manufactures cam anent a royal forinstallation requirements.
4 The Dow Chemical Co. TILE BOND' Roof Tile Adhesive weight per patty 11.4 grams. 26.1
5 ICP Adhesive and Sealants, Inc. ICP Adhesve PolysetO AH-160 Two -Component weight per patty 8 2rams 26.1
6 DAP Foam Touch N Seal StonnBondo 2 Roof Tile Adhesive weight per paddy 8 grams. 3&0
Table 6: Attachment Resistance Expressed as a Moment - Mt (ft-lbf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Boral Estate'S' Roof
Tile
Adhesive
7 See manufactures component approval for Installation requirements.
8 ICP Adhesive and Sealants, Inc. ICP Adhesve Pol set® AH-160 Two -Component weight per patty 54 grams. 86.61
9 ICP Adhesive and Sealants, Inc, ICP Adhesve Po set® AH-160 Two -Component weight per patty 24 grams 45.5
i O DAP Foam Touch N Seal StormBondo 2 Roof Tile Adhesive weight per paddy 60 grams. 60.0
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft.-lbf)
for Mortar or Adhesive Set Systems
Tile
Tile Application
Minimum Attachment
Profile
Resistance
Boral Estate'S' Roof
Mortar Set .
20.60
Tile
MIAMFBAUE COUNTY
NOA No.18-0829.03
wwanwilmow Expiration Date: 0823121
Approval Date: 10/11/18
Page 5 of 7
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
Ge ,
BORAL ESTATE "S" TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
MIAMItM21COt1NTr NOA No.18-0829.03
®l `'• Expiration Date:0823/21
Approval Date: 10/11/18
Page 6 of 7
Nail Holes
PROFILE DRAWING
BORAL ESTATE "S" CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
4
NOA No.18-0829.03
Expiration Date: 0MU21
Approval Date:10/11/18
Page 7 of 7