HomeMy WebLinkAboutPAUL WELCH ENGINEERING PAPERWORKRECEIVED PAUL WELCH INC. MAY 13 2019 Mechanical Electrical Civil Engineering permitting Dopartment 1984 S.W. Biltmore St. Suite#114 St. Lucie Countv Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 E-mail pwelchinc@aol.com SCANNED BY St. Lucie County May 10, 2019 Re: Rispoli Re -Roof 10725 S Ocean Dr. #125 Jensen Beach, FL SCOPE OF WORK: Install new Metal Roof (Extreme Metal Fabricators, LLC 1" Nailstrip FL #20378.2) at the above referenced address over new underlayment, and existing plywood sheathing. DESIGN CRITERIA: FBC 2017 ASCE7-10 PROJECT DATA: BUILDING HIEGHT=11'-0" A= 3' MEAN ROOF HIEGHT = <15' ROOF ANGLE = 7:12 SHAPE = PITCHED GABLE ADJUSTMENT FACTOR = 1.00 IMPROTANCE FACTOR = 1.00 WIND VELOCITY V ult = 165UTH WIND VELOCITY V asd =128 MPH MA-ZOA"n moil ENCLOSURE CLASS = ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT = -0.18 APPLIED UPLIFT DESIGN PRESSURES PER ASCE (PSF): ZONE I (Field) = -40.3 ZONE 2 (Perimeter/ Ridge) = -68.0 ZONE 3 (Comers) = -99.8 Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 May 10, 2019 10725 S Ocean Dr. #125 Jensen Beach, FL 1 of 3 Q LU mJ LL Metal roofing to be attached with corrosion resistant Pancake -Head wood screws #10 a 1" minimum (minimum 3/16" penetration through deck). Fasteners shall be placed through the nailing strip at 16" on center across panel width and spacing nailstrip as follows: ZONE 1 (Field): FASTENER SPACING = 6" O.C. ZONE 2 (Perimeter/ Ridge): FASTENER SPACING = 6" O.C. ZONE 3 (Corners): FASTENER SPACING = 6" O.C. (WITH 3/8" BEAD OF SEAM ADHESIVE) Design uplift Pressure for attachment as per above: Product Design Pressure: Zones I & 2:-69.25PSF / Zone 3:-121.75PSF Therefore O.IC UNDERLAYMENT: Underlayment shall be in accordance with manufacturer's guidelines, FBC 1507.4.5.1, and FBC 15074.5.2. Underlayment shall be Polyglass Polystick TU Plus FL# 5259.1 DECK INSTALLATION: Re -nail all plywood sheathing (15/32" thick minimum) with 8D ring -shank nails at 4" O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL # 20378.2), manufacturer's specifications, and the Florida Building Code 2017. Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 May 10, 2019 10725 S Ocean Dr. #125 Jensen Beach, FL / 2 of 3 zAPA,e ROOF ZONE PLAN A=3' QQQ,Q= ZONE DESIGNA770N(TYPICAL) NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT.:12 HORZ. Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 May 10,2019 • i_ 10725 S Ocean Dr. #125 Jensen Beach, FL 3 of 3