HomeMy WebLinkAboutENERGY EFFICIENCY CODEMAY 141019
peu,,,-1 j;,ie Couny
St
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONr�S TION
Florida Department of Business and Professional Regulation - ResidenlIJILI. - I M thod
Project Name: RJM PINEWOOD ALLIH 2232
Builder Name: RJM CUSTOM HOMES INC
Street: 4705 ELM AVE
PermitOHice: FORTPIERCE
City, state, Zip: FT PIERCE. FL,
Permit Number:
Owner.
Jurisdiction: 661100
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2424.2 soft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int Insul, Exterior
R=4.1 2110.00 W
b. Frame -Wood, Adjacent
R=11.0 314.17 ft
3. Number of units, if multiple family 1
c. WA
R= ft2
4.. Number of Bedrooms 4
d. N/A
R= ft2
10. Ceiling Types (2232.0 sgft.)
Insulation . Area
5. Is this a worst case? Yes
a. Roof Deck (Unvented)
R=20.0 2232.00 ft2
6. Conditioned floor area above grade 2232
b. N/A
R= ft'
0. N/A
R= ft2
Conditioned floor area below grade (W) 0
11. Ducts
R f12
7. Windows(304.6 sqft.) Description Area
a. Sup: Attic, Rat. Attic, AH: Main
6 157
a. U-Factor: 691, U=0.52 304.61 ft2
SHGC: SHGC=0.30
b. U-Factor: WA fN
12. Cooling systems ��eekkrgBg�gtu/hr Efficiency
SHGC:
a. Central Unit �MR1Ytl1�IV`lSLLA6.0.
B,ty�pgayp�,ty�'
SEER:14.50
c. U-Factor. N/A fl2
ng systems ��e Efficiency
13a„Electric
d. UFactor. N/A ft2
Heat Pump
4y0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 8.428 ft.
Area Weighted Average SHGC: 0.300
14. Hot water systems
a. Electric
Cap: 50 gallons
6. Floor Types (22$2.0 sgft.) Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation R=0.0 2232.00 ft2
b. Conservation features
b. NIA R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
0.136 Total Proposed Modified Loads: 78.09
@i
PASS
Glass/Floor Area:
Total Baseline
Loads: 79.01
/,►a7a7
I hereby Car dvolt a ei 1 and sp c &cations cover by
Review of the plans and
04SSE ST,q?,
this calculation are in compliance with the Florida Energy
specifications covered by this
��' _ ,=; 0
Code.
calculation indicates compliance'-
with the Florida Energy Code.
�_
PREPARED BY:
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this I uilding, as designed, is in compliance
Florida Statutes.
0�
D WE
with the Florida En
OWNER/A
BUILDING OFFICIAL:
DATE: O
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4IM019 1:35 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 5
FORM R4 5 2017
..eau .r nrlaa aawov ^UC/,VI ICY oCo(loY
rr.�.....,........,-.... _ — — —
— -
PROJECT
Title:
RJM PINEWOOD ALLIH 223
Bedrooms: 4
Address Type: Street Address
Building Type:
User
Conditioned Area: 2232
Lot#
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units:
1
Wont Case: Yes
PlatBook:
Builder Name:__
RJM CUSTOM.HOMES INC
.Rotate Angle: 225. _ _
__Street:.
47M ELM AVE
Permit Office:
FORT PIERCE
Cross Ventilation:
County: St. Lucie
Jurisdiction:
651100
Whole House Fan:
City, State, Zip: FT PIERCE,
Family Type:
Single-family
FL.
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design
Temp Heating Design DailyTemp
Design Location TMY Site
97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name Area
Volume
1
Blockl 2232
20088
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main 2232
20088 Yes 8
4
1 Yes Yes Yes
FLOORS
#
Floor Type Space
Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 209 ft 0
2232 fP
-- 0 0 1
ROOF
Roof Gable Roof
Solar
SA Emitt Emilt Deck Pitch
Tested Tested Insul. (deg)
#
Type Materials
Area Area Color
Absor.
1
I
Hip Metal
2418 ft' 0 ft2 Unfinishe
0.96
No 0.4 No 20 22.6
ATTIC
#
Type Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Partial cathedral cal Unvented 0 2232 ft
N Y
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Free Truss Type
1
Under Attic(Unvented)
Main 0 Blown
2232W 0.11 Wood
418120191:35 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
IAIOI 1T et IRMMMA ov
TEMPERATURES
PmgramabiflingfeXllThermostat: Y
Ceiling Fans:Coo
Vent ng
FebfX11
Feb
fJan
Mar
AprApr
May Jun
Jul
([X1I
ff
Nov
[fX1]
ec
�X�
[ ]Jan
IXJ
[
AugAug
j
]Sep
(JC�
Oct
[ ]X Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5
6 7
8
9
10 .
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78 78
78 78
78
80
80
80
80
78 78
78 78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78 78
78 78
78
78
78
78
78
78
78
78 78
78 78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66 66
68 68
68 68
68
68
68
68
fib
68 68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
68
66
66 66
68 68
68
68
68
68
68
68
68 68
68 68
68
68
68
66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM
Fan Watts HRV
Heating System
Run Time
Cooling System
None
0
0
0 1 - Electric Heat Pump
0%
1 -Central Unit
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default a Ibsfsq.ft.
0 ft.
Oft
0.3
Main
Name: Jeff Signature:
Rating Compant: Jeff Date:
4/8/2019 1:35 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX` = 99
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Duds, location 6 insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return duds R
6.0
c) AHU location Attic/Attic
3. No. of units (ifmultiple-family)3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
46.0
a) Split system SEER
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Groundiwater source SEER/COP__
6. Conditioned floor area (sq. ft.)
S.
2232
d) Room unit/PTAC EER
e) Other
14.5
7. Windows, type and area
a) U-factor;(weighted average)
7a.
0.520
b) Soler Heat Gain Coefficient (SHGC)
7b.
0.300
14. Heating system: Capacity
45.0
c) Area
7c.
304.6
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-fador:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
8.20
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.92
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
0.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11C.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:_ S/10,1/141
Address of New Home: 4705 ELM AVE City/FL Zip: FT PIERCE. FL
4/8/2019 1:35:20 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 4705 ELM AVE Permit Number:
FT PIERCE, FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
El display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 563.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
Installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section 0402.6.
R402.4.1 Building thermal envelopoe building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.
The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturers instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or Individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the parry conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
Infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
S. Heating and cooling systems, if installed at the time of the test, Shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood-buming fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled In accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air IeakageWindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 ofm per
square foot (1.5 Us/m2), and swinging doors no more than 0.6 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
AAMA/ WOMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
4/8/2019 1:35 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 1 of 5
. MANDATORY REQUIREMENTS - (Continued)
. ❑R402.4.4 Rooms containing fuel-buming appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shaitbe insulated where It
_ passes through conditioned space to a minimum of R•8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be (Grated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested In accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electrio-resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5):or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (I), Florida Statutes, to be "substantially leak fre.e' in
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1 ,
1, Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure If installed at the time of the test. All registers shall be taped or otherwise sealed during�the test.
2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the .
entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑R403A Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C)
or below 556F (13'C) shall be insulated to a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping Insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return
❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot waterwithin the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
r when there is no demand for hot water.
❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
4/8/2019 1:35 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 31fi inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
�- R403.5.6.1-.1 Automatic controls. Service water -heating systems shall be equipped with automatic tempe..rature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140°F (38`C to 60°0).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main bumer(s) of
combustion types of service water -heating systems to be turned off.
R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, forthe type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all staled requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2A.
R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solarenergy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TMA, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air Intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive Indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be, the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall he
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law forthe geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMU
(CFM)
Range hoods
Any
2.8 clmlwalt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfmlwatt
Any
For SI: 1 rim = 28.3 Umin. a. When tested in accordance with HVI Standard 916
4/812019 1:35 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
oR403.7.1.1 Cooling equipment capacity., Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer s
expanded performance data shall be used to select cooling -only equipment. This selection Shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains If the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its wolfing capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by aFlorida-registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
R403.7.1.2.2 Electric resistance fumaces. Electric resistance furnaces shall be sized within 4 kW of the design•
requirements calculated according to the procedure selected in Section R403.7.1.
Fi R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners- ` •`
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events„shall have equipment sized or controlled to..
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. t.'i
2. A variable capacity system sized for optimum performance during base load periods is utilized. -
ElR403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
shall include automatic controls capable of Shutting off the system when the pavement temperature Is above 50°F (10°C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature Is above 40'F (4.8'C).
❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric. power to heaters shall be controlled by a readily accessible on -off switch that is an
integral pad of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat Such switches shall be in add'dlon to a circuit breaker for the
power to the heater. Gas -fired heatersshall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
r Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from wheat pump or solar energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas -and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
❑ efficiency of 82 percent for heaters manufactured on or after April 16. 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
4r81201g 1:35 PM EnergyGauge3l USA - FBC 6th Edition (2017) Compliant Software Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
• with AHRI 1160, Table 2, Standard Rating Condltlons-Low Air Temperature. A lest report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas (MandatorgOhe energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment (Mandatory), Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps.
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
4/8/2019 1:35 PM EnergyGaugeO USA - FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: RJM PINEWOOD ALLIH 2232 Builder Name: RJM CUSTOM HOMES INC
Street: 4705 ELM AVE Permit Office: FORT PIERCE
City, State, Zip: FT PIERCE, FL, Permit Number.
-
Owner. Jurisdiction: 661100
w
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks orjoints in the air barrier shall be sealed,
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier._
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the tap side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utilitypenetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
-cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind nining And Wring
-Showerttub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
. Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log walls shall be in accordance win me provisions or i ,v uu.
4/a/2019 1:35 PM EnergyGaugeO USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 ,inch w.g. (50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(0, (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, Intake, makeup air, back draft and flue dampers shall be dosed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Company Name. Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above,
Signature of Tester.
Printed Name of Tester:
License/Certification #:
Date of Test:
Issuing Authority:
4/8/2019 1:35:24 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test) .
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: 661100 Permit #:
_ Job lnfotlnatton. '' � ,+
Builder. RJM CUSTOM HOMES INC Community: Lot: NA
Address: 4705 ELM AVE
City: FT PIERCE State: FL Zip:
Air Leakage Test lieslalts Passing resulfsmustmeet eitherthe Performance Prescn(a 'y orER( Method
O-!PRESCRIPrT)VE MEf'}IOR-TI]ebulldingo{dwelhng;upttsha([befesCed and;ver(fief as hawrigary au leakage iafe ofhot exceeding7ain
changes yerhour at a 7iressuregf 0.2 mdh wg. (50 Pascals),m Ghr�iate2ones t abd2� -
Q;;PERF4RMANCE qr ERt ME7HDL The EuITd}ng qr dwelhogvnR shall be testedand verified ashavmg an alrleakage rate df notexceeding.
the selected AGH(5Q)value assfsown orvl=om)iR,40520.j7 (Pedomlance)sm R4062017 (ERt) �sedroit labeled as infiltration, su6.seeton RCLi50:
ACN(50j spe"o�ed'on For(n`R40S201T EneKJy Calc'.(Perfor,[nangB) orR4gB-20f7 (ERt) 7.000 ;
x 60 + 20088 — Method for calculating building volume:
CFM(50) Building Volume ACH(50)
• 0 Retrieved from architectural plans ❑
PASS 0 Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
i must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET11CC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7). Florida Statues.or individuals licensed asset forth in Section
• 489.105(3)(f), (g), or(!) or an approved third party. Awritten report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
• - 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other Infiltration
control measures. '
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, If Installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
S. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Test ng Company
i.
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above..
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
4/8/2019 1:37:01 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Residential System Sizing Calculation
Summary
Project Title:
4705 ELM AVE RJM-PINEWOOD ALLIH 2232
FT PIERCE, FL
4/8/2019
Location for weather data: Fort Pierce, FL - Defaults: Latitude(27.48) Altitude(25 ft.) Temp Range(L)
Humidi data: Interior RH 50%
Outdoor
wet bulb 78F Humiditv difference 62 r.
Winter design temperature(TMY3 99%) 40
F
Summer design temperature(TMY3 99%) 91
F
Winter setpoint
70
F
Summer setpoint
75
F
Winter temperature difference
30
F
Summer tem erature difference
16
F
Total heating load calculation
36637
Btuh
Total cooling load calculation
41782
Btuh
Submitted heating capacity
% of calc
Btuh
Submitted cooling capacity
% of calc
Btuh
Total (Electric Heat Pump)
122.8
45000
Sensible (SHR = 0.75)
116.0
34500
Heat Pump + Auxiliary(O.OkW)
122.8
45000
Latent
95.4
11500
Total Electric Heat Pump)
110.1
46000
WINTER CALCULATIONS
Winter Heatino Load (for 2232 soft)
Load com onent
Load
Window total
305
sqft
4752
Stuh
Wall total
2052
sqft
8705
Btuh
Door total
68
sqft
938
Btuh
Ceiling total
2232
sqft
3204
Btuh
Floor total
2232
sqft
7399
Btuh
Infiltration
161
cfm
5307
Btuh
Duct loss
6332
Btuh
Subtotal
tM1RILf(L3.B:5j
36637 Btuh
Window total
305 sqft
8246
Btuh
Wall total
2052 sqft
4643
Btuh
Door total
68 sqft
970
Btuh
Ceiling total
2232 sqft
2777
Btuh
Floor total
0
Btuh
Infiltration
121 cfm
2123
Btuh
Internal gain
6240
Btuh
Duct gain
4735
Stuh
Sens. Ventilation
0 cfm
0
Btuh
Blower Load
0
Btuh
Total sensible gain
29733
Btuh
Latent gain(ducts)
5364
Btuh
Latent gain(infiltration)
5086
Btuh
Latent gain(venblation)
0
Btuh
Latent gain(internal/occupants/other)
1600
Btuh
Total latent gain
12049
Btuh
TOTAL HEAT GAIN
41782
Btuh
I" `HI1161Po.1
EnergyGauge® / USRCZB v6.0
Wrills(11.14oj
Lrilingzl,A,7;;}
kkwlnEo-nh3.YSj
ouul»a!�I
I�ml.liasvy
Ceilingsf8.o%)
fthk:^tlntlmvsfl9.i°5j
FLatent int(3.13°.'°l,
Int.Giiin(14.9%i
System Sizing Calculations - Summer
Residential Load - Room by Room Component Details
Project Title:
4705 ELM AVE RJM PINEWOOD ALLIH 2232
FT PIERCE, FL
4/8/2019
Reference City: Fort Pierce, FL Temperature Difference: 16.0F(fMY3 99%) Humidity difference: 62gr.
This calculation is for Worst Case. The house has been rotated 270 degrees.
Type"
Overhang
Window Area(sqft)
HTM
Load
Window
Panes SHGC U InSh
IS Ornt
Len
H t
Gross Shaded Unshade
Shaded
Unshaded
.
1
1 NFRC 0.30, 0.52 No
No
W
, 13.Of
2.Oft
18.0
18.0 0.0
15
37
265
Btuh
2
1 NFRC 0.30, 0.52 No
No
NW
14.Of
2.Oft
33.3
0.0 33.3
15
29
960
Btuh
3
1 NFRC 0.30, 0.52 No
No
W
15.Of
1,Oft
64.0
64.0 0.0
15
37
943
Btuh
4
1 NFRC 0.30, 0.52 No
No
S
23.Of
I ..1
10.0
10.0 0.0
15
16
147
Btuh
5
1 NFRC 0.30.0.52 No
No
SW
15.0f
1.Oft
10.0
10.0 0.0
15
29
147
Btuh
6
1 NFRC 0.30.0.52 No
No
IN
1O.Of
t.Oft
10.0
10.0 0.0
15
37
147
Btuh
7
1 NFRC 0.30.0.52 No
No
W
2.Oft
1.011
15.0
2.0 13.0
15
37
517
Btuh
8
1 NFRC 0.30. 0.52 No
No
N
2.011
0.5ft
15.0
0.0 15.0
15
15
221
Btuh
9
1 NFRC 0.30, 0.52 No
No
N
2.Oft
0.5ft
6.0
0.0 6.0
15
15
88
Btuh
10
1 NFRC 0.30. 0.52 No
No
N
2.Oft
0.5ft
15.0
0.0 15.0
15
15
221
Btuh
11
1 NFRC 0.30,:0.52 No
No
E
2.Oft
0.5ft
31.5
5.2 26.3
15
37
1061
Btuh
12
1 NFRC 0.30, 0.52 No
No
E
11.Of
0.111
12.0
12.0 0.0
15
37
177
Btuh I
13
1 NFRC 0.30, 0.52 No
No
E
2.Oft
Loft
15.0
2.0 13.0
15
37
517
Stuh
14
1 NFRC 0.30, 0.52 No
No
NE
2.0ft
1.Oft
8.0
0.0 .8.0
15
29
230
Btuh
15
1 NFRC 0.30, 0.52 No
No
E
2.Oft
1.Oft
16.0
2.6 13.4
15
37
539
Btuh
16
1 NFRC. 0.30, 0.52 No
.No
SE
2.Oft
1,Oft
8.0
5.0 3.0
15
29
161
Btuh
17
1 NFRC U304.52 "No
No
S
2.Oft
1.Oft
17.8
17.8 0.0
15
16
262
Btuh
Window Total
305 s ft
1 •6605
Btuh
Walls
Type .
_
U-Value
R-Value
Area(sqft)
HTM
Load
Cav/Sheath
1
Concrete Bik,Hollow -Ext,
0.15
4.110.0
373.0
2.4
891
Btuh
2
Concrete Blk,Hollow -Ext'
0.15
4.110.0
46.7
2.4
111
Btuh
3
Concrete Blk,Hollow -Ext
0.15
4.110.0
434.0
2.4
1035
Btuh
4
Concrete Blk.Hollow -Fxt
0.15
4.110.0
82.0
2.4
196
Btuh
5
Concrete BIk,Hollow - Ext
0.15
4.110.0
187.5
2.4
448
Stuh
6
Concrete Blk,Hollow- E)a
0.15
4.1/0,0
42.0
2.4
100
Btuh
7
Concrete Bik,Hollow - Ext
0.15
4.110.0
552.2
2.4
1319
Btuh
8
Concrete Blk,Hollow - Ext
0.15.
4.1/0.0
40.0
2.4
96
Btuh
9
Frame - Wood • Adj
0.09
11.0/0.0
74.2
1.5
113
Btuh
10
Frame - Wood •Adj '
0.09
11.0/0.0
190.0
1.5
2B8
Btuh
11
Frame -Wood -Adj
0.09
11.0/0.0
30.0
1.5
46
Btuh
Wall Total
2052 (s ft)
4643
Btuh
Doors
Type
Area(sgft)
HTM
Load
1
Insulated - Exterior
48.0
.14.3
684
Btuh
2
Insulated -Garage
20.0
14.3
285
Btuh
Door Total
66 (sgft)
970
Btuh
Ceilings
Type/Color/Surface
U-Value
R-Value
Area(sqft)
HTM
Load
1
Unvented Attic/Ught/Matal
0.048
0.0/20.0
2232.0
1.24
2777
Btuh
Ceiling Total
2232 sgft
2777
Btuh
Floors
Type
R-Value
Size
HTM
Load
1
Slab On Grade
0.0
2232 (R-perimeter)
0.0
0
Btuh
Floor Total
2232.0 Isgft
0
Btuh
Zone Envelope Subtotal:
14994
Btuh
EnergyGauge® / USRCZB v6.0 Page 1
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL VERO_BEACH_MUNICIPAL_A
4705 ELM AVE RJM PINEWOOD ALLIH 2232
FT PIERCE, FL
4/8/2019
Windows
July excursion for System 1
1641 Btuh
Excursion Subtotal:
1641 Stuh i
Duct load
311 Btuh
1
Sensible Excursion Load
1961 Btuh
EnergyGauge® / USRCZB v6.0 Page 2
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL_VERO_BEACH_MUNICI PAL_A
4705 ELM AVE RJM PINEWOOD-ALLIH 2232
FT PIERCE, FL
4/8/2019
Sensible Envelope Load All Zones
24998 Btuh
Sensible Duct Load
4735 Btuh
Total Sensible Zone Loads
29733 Btuh
Sensible ventilation
0 Btuh
Blower
0 Btuh
Whole House
. Total sensible gain
29733 Btuh
Totals for Cooling
Latent infiltration gain (for 62 gr. humidity difference)
5086 Btuh
Latent ventilation gain
0 Btuh
Latent duct gain
5364 Btuh
Latent occupant gain (8.0 people @ 200 Stuh per person)
1600 Btuh
Latent other gain
0 Btuh
Latent total gain
12049 Btuh
1. Central Unit # 46000 Btuh
*Key; Window types (Panes - Number and type of panes of glass)
(SHGC- Shading coefficient of glass as SHGC numerical value)
(U - Window U-Factor)
(InSh- Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R))
- For Blinds: Assume medium color, half closed
For Draperies: Assume medium weave, half closed
For Roller shades: Assume translucent, half closed
(IS - Insect screen: none(N), Full(F) or Half('))
(Ornt - compass orientation)
EnergyGauge® / USRCZB v6.0
Page 3
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation .
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the
residential Simulated Performance Method shall include:
Cis checklist
Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a -ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst -case
orientation, name and version of the compliance software tool, name of individual
co pleting the compliance report (one page) and an input summary checklist that can
1e used for field verification (usually tour pages/may be greater).
0 nergy Performance Level (EPL) Display Card (one page)
MVAC system sizing and selection based on ACCA Manual S orper exceptions provided in Section R403.7
andatory Requirements (five pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4. 1. 1 -
one page)
❑ A completed Envelope Leakage Test Report (usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report (usually one page)
4/8/2019 1:35:16 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 ci 1