HomeMy WebLinkAboutGENERATOR PAPERWORK16/20/22 kW
RE ,�m - GENERAC'
MAY 14 2019
3-c,Ludecounty, Permitting GUARDIAN®.SERIES
Residential Standby Generators
Air -Cooled Gas Engine
INCLUDES:
• True Power'" Electrical Technology
• Two Line LCD Multilingual Digital
Evolution'" Controller (English/Spanish/
French/Portuguese)
• Two Transfer Switch Options Available:
100 Amp, 16 Circuit Switch or
200 Amp Service Rated Smart Switch.
See Pa e 4 for Details
FILE C0PY Standby Power Rating
Models G007036-0. G007037-0 (Aluminum - Bisque) - 16 kW 60 Hz
Model G007035-0 (Aluminum
Models G007039-0, G007038-0 (Aluminum
Models G007043-1. G007042-1 (Aluminum
ST.LUCIE COUNT
PLAN REVIEW
g
BLDG:
• Electronic Governor
DATE:���
• System Status & Maintenance Interval LED
ELEOyrI/1WA lQ"
Indicators
DA-tg;i n� -/"/9
• Sound Attenuated Enclosure
PLUMB-
• Flexible Fuel Line Connector
DATE
MECH:DATE.
• Direct -To -Dirt Composite Mounting Pad
• Natural Gas or LP Gas Operation
• 5 Year Limited Warranty
• Capability to be installed within 18" (457 mm)
of a building*
FEATURES
O INNOVATIVE ENGINE DESIGN& RIGOROUS TESTING are at the heart of Genemc's O
success in providing the most reliable generators possible. Generac's G-Force engine
lineup offers added peace of mind and reliability for when you need it the most. The
G-Farce series engines are purpose built and designed to handle the rigors of
extended run limes in high temperatures and extreme operating conditions.
O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave (D
loan produce less than 5%Total Harmonic Distortion for utility quality power. This allows
confident operation of sensitive electronic equipment and micro -chip based appliances,
such as variable speed WAC systems.
Bisque) - 16 WV 60 Hz
Bisque) - 20 kW 60 Hz
Bisque) - 22 kW 60 Hz
County
OOs LISTEDUIE— E7S
Note: CUL ceniticalion only applies to unbundled units and units packaged with
limited circuit switches.. Units packaged with the Smart Switch are UL cedihed In
the USA only.
-On y if located away from doors. windows and fresh air intakes.
and unless otherwise directed by local codes.
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION:
This state -of -fire -art power maximizing regulation system is standard on
all Generac models. II provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at �1%.
SINGLE SOURCE SERVICE RESPONSE from Genemc's extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
TEST CRITERIA: v GENERAC TRANSFER SWITCHES: Long life and reliability are
PROTOTYPE TESTED NEMA M01-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this
SYSTEM TORSIONAL TESTED , MOTOR STARTING ABILITY confidence is that the GENERAC product line Includes its own transfer
systems and controls for total system compatibility.
w GENERAC ry>�: r��� �qk�
�. k
PROMISE qbe
P !P J` SIggO�
NHN W utl.usq e.m�avem,ay, Ma
GENERAC
16/20/22 kW
specifications
Generator
Model
G007035.0, 6007036.0.
G007038-0, G007039-0 G007042-1, 13007043.1
G007037-0 (16 kW)
(20 kW)
(22 kW)
Rated Maximum Confinu`obs Power Capacity(LP) .-
-"_ 16,000 Watts}- -
20000Wztls7
- 22,CD0; -
Bated Maximum Continuous Power Capacity RIG)
16,000 Wafs'
18,000 Wafts'
19.500
Rated Voltage =' - -
- '7 240_'
_ 240:
240- .
Rated Maximum Continuous Lead Current -240 Volts (U?/NG)
66.6166.6
93.3175
91.6/81.3
-Total Harmonic DlsloNou fir ,
Less than 5%•. -
_'. Len tliaii5%
.Less Ran 5%` -
MainLineCircuitBreaker
76 Amp
16 Amp
..
100 Amp
-0N
1.
-
Number of Rotor Poles
� 2
�2
� � � 2
Reled AC Frequency,' _•;-'., ..'
rb..
"z-
.-.n, ..._. .r y._.
Power Factor
1.0
1.0
1.6
B50eryRequnemenl (do(fncluded), 4.'1 ." s
c. 12 VdIts Grou
CCA Mlnrmom gr Grdu 35AGM 650CCA Mmlmum,.
....:_ .. ..
Unit Weighl(16/Rg)
406/186
448/203
46kll
Dimensions(Lx W,rH nt7mm 1 ,,,
,.,_.r„v,} s,
48z 25 z29/1218—x638x732,1"�'j.
,
Sound output In dB(A) at 23 R (7 m) with generator operating at normal loot!"
_,: a,
66
66
67
Engine
Type of Eng
Numtiei of
Displaceme
Cylin'deF81i
Valve Arran
Igniii"ere Sy3
Governor St
ComD?S 1i
Starter
Controls
GENERAC G-Force 1000 Series
OR4, „,'r r'rS � '�'- ""�? ,. ,F
k",,�.-v t Slops un4 Power lsTem'T'Conkgland'ehar er slilfopem[e ��7',F;?
Ready to RurVMaimenance Messages
Standard
EnpIli e Run HoursgMlcabgq'-'r" �.;•�;
..- t , anSlandud.-.: �'�
.:., _,. _'a..,
Programmable start delay between 2-1500seconds
,:-„'?
Standard (programmable by dealer only)
_UOliry'Yoltage LassRleNm(o UNityAajustahle (Brownout Se8lip}�; ;' ;: `'
--. ,-`,'From 140.174V%L90±216
V,, _> '�"`
FuWte gel Capable Exerciser/Exercise Set Error Warning
.3-t
Standard
Roe/Alarm/Malnt--- ho_9's �.- 1' .
.
z 503yents oath _
Engine Stan Sequence
Cyclic cranking: 16 see on, 7 rest (90 see maximum duration).
Starts eannof re-e gageun CjS e414 engine hasstopped -- ,
Smart Battery Charger
Standard
charger FaulYMissiBgACWermngy '' '-
•" - Standaro '_ , . ,
�
Law Baltery/Baltery Problem Protection and Gallery Condition indication
Standard
ANomaOi Volta_
Staddll- . _-
Under-Frequency/Ovenoad/Slepper Overcumpal Protection
Standard
Safety Fdsed(Fuse PF61:k6n Protection-'.'_ -�- -
__.' .' - -- Skndaid •': - -..
Automalic Low Oil Pressure/High Oil Temperature Shutdown
_
Standard
OvercrarlyNaMpeeQ((fi?72 ftz)4ih Sense Loss Shutdown 'r
- _ - .,- ,Standard -,•; - r. _ ,.
High Engine Temperature Shutdown
Standard
Internal FiulVlncarrectWlring Pmteegoh`; i, .•, _ >;
- ->' , i, ' ;. , ,.. Standard. -.�
_-
Common External Fault Capability
_. ,,,
Standard
Feld Upgladable FiRivaie - • _.fP.P ' -
},`,` , - Stan ard;: - ("
-Spend leveh are taken horn Are lgnl olhis generator. spend lmeh6ken an anagifeea Are fors m^wlbe
higher dependog mi humndpn penmen:rs. Pairs derwtipm- StamocAppOrabk lursupphvg emerge,cypmer lorNetlYglion
w deugMppwerpubge. Nooxdsedpape6dybadibble brWhraWg. WIakgsinacm0anceww�855514, 15g3g46aM dm62111.'Mmim EtmohaMsardnmerAnwbjedHardih edbfmdttadmemhre3BWmegaiale
p�lentamdienlle�e'anae,ahiWde,mgirsporaandcwtlnion, eh. MDdno mrdeaeasesaban3.5permnlwmch 1,hg01efl(304.emetm)MmesmkvetaWa Mlltleupase dI puma lmeach6°C(Ib'Fabm 16-C(601).
GENERAC'
16/20/22 kW
features and benefits
Engine
•
GeneracG-Force design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinderwalls and plasma moly rings helps the engine
run cooler, reducing oil consumption resulting in longer engine life.
•
"Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
•
Electronic ignition/spark advance
These features combine to assure smooth, quick starling every time.
•
Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur-
ing up to a 2 year/200 hour oil change interval.
•
Low ail pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
•
High temperature shutdown
Prevents damage due to overheating.
Generator
•
Revolving field
Allows fora smaller, light weight unit that operates 25% more efficiently than a revolving armature generator.
•
Skewed stator
Produces a smooth output waveform for compatibility with electronic equipment.
•
Displaced phase excitation
Maximizes motor starting capability.
•
Automatic voltage regulation
Regulates the output voltage tomt%prevents damaging voltage spikes.
•
UL2200listed
For your safety.
Transfer Switch (if applicable)
•
Fully automatic
Transfers your vital electrical loads to the energized source at power.
•
NEMA 3R
Can be installed inside or outside for maximum flexibility.
•
Remote mounting
Mounts near your existing distribution panel for simple, low-cost installation.
Evolution'" Controls
•
Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
•
Two-line LCD multilingual display
Provides homeowners easily visible lags of history, maintenance and events up to 50 occurrences.
•
Sealed, raised buttons
Smooth, weather -resistant user interface for programming and operations.
•
Utility voltage sensing
Constantly monitors utility voltage, setpoints 65%dropout, 80%pick-up, of standard voltage.
•
Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
•
Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a
qualified dealer.
•
Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
•
Engine cool -down
Allows engine to cool prior to shutdown, selpoint approximately 1 minute.
•
Programmable exercise
Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every
other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel
costs to the owner.
•
Smart battery charger
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
•
Main line circuit breaker
Protects generator from overload.
•
Electronic governor
Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150
mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat-
ically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
• Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18' away from a building.
Installation System
• 1 It (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe.
• Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system.
0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life.
16/20/22 kW
INddel #
G007005-0
,GO06463-0
G005819-0
:GO07101-0
�:GO07102-0
G005621-0
GENE AC
MUMEMN
available accessories
Product
OescriplronC i
_=
,
The Wi-H enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank Mon-
Boring the LP tank's fuel level is an important step in making sure your generator is ready to run during an
Wi-R LP Fuel Level Monitor
unexpected power failure. Status alerts are available through a free application to notify when your LP tank
is in need of a refill.
Genemc's Mobile Link allows you to check the status of your generator from anywhere that you have ac-.
! Mobile Link-
cess to an Internet connectton from a PC or with any smart device. You will even be notified via e-mail or
text message when a change in the generator's status occurs. Available in the U.S. only.
I Every standby generator requires a battery to start the system. Genemc otters the recommended 26R wet,
I26R Wet Cell Battery
cell battery for use with all air-cooled standby product (excluding PowerPact®).
i Battery Pad Wanner
l The pad warmer rests underthe battery. Recommended for use if the temperature regularly falls below 01.
batteries).
(Not necessary for use with AGM -style
Oil warmer slips directly over the oil filler.Recommended for use B the temperature regularly falls below
Oil Wanner
G°F.
r G007027-0 - Bisque
! G005703-0 - Bisque
i
!G006485-0
G006873-0
uxiliary Transfer Switch
{ The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load
ontact Kg
! you may not need. Not compat ble with 50 amp pre -wired switches.
The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a 1
ascia Base Wrap Kit
itandard on 22 kW)
i sleek, contoured appearance as well as offering protection from rodents and Insects by covering the lihingi
l holes located in the base.
If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from '
abut Kitfuture
corrosion. The paint kit includes the necessary paint to property maintain or touch-up a generator
)enclosure. I
Generac's scheduled maintenance kits provide all the hardware necessary to pedorm complete routine
cheduled Maintenance KB
(maintenance on a Genemc automatic standby generator. '
mart Management Module
I Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its
50 Amps)
power management capabilities. it provides additional power managementflexibirity not found in any other!
power management system.
dimensions & UPCs
Gimensiuns shmmare approumele. Refer to installation mantel for exact O'mensiom. 00 NOT WE THESE OPAENSIONS FOR KSTALATION PURPOSES.
I
I L�
i
I,
t i
rsq I -_
LER 91rsENEW
FROM VIEW
Model
UPC
G007035-0
696471070354
G007036-0
696471070361
G007037-0
696471070378
G007038-0
696471070385
G007039-0
696471070392
G007042-0
696471070422
G007043-0
696471070439
G E N E R AC` Generac Power Systems, Inc. F S45 W29290 HWY. 59, Waukesha, WI 53189 a genemc.com
12017 GeIR2e Po., Systems. Inc.All nghls reserved. Aa speciticalions ne suhkal m change mimout notice. Part Na. 10000000194-F 513'17
16/20/22 kW
GENERAC'
specifications
Generator
Model
G007035-0, G007036-0, G007038-0, 0007039-0
G007042-1, G0070434
G007037-0 (16 kW) (20IN)
(22 kM
Rated Maxim on Con6nudus Power Capacity '�•
. --
16,000 Watts' - 20,000 Walls'>-
22; 000
RatedMaimumContinuousPawerCapacity(NG)
16,000 Watts' 1$000 Watts-
19,500
,fl3ted Volt50e--
- •240- _ -_ 240
Rated Maximum Continuous Load Current— 240 Volts(LP/NG)
66.6/66.6 83.3/75
91.6/81.3
Total Harmonic Distortion - -
Less Nana% Less than 5%
.•' ":Less tfiari 5%
Main Line Circuit Brreaker
70 Amp 100 Amp
100Amp
Plisse :. _ '- ,;'. ".''C. •;.
``.
_ 1 _;' . .1`_ c
a 1 i--.' ..
Numher of flolar Poles
2 2
2
BateUAC.Ffequenq, . . r
`�6011z. ...�,. 60 Hz ,
._: ; 60Hz .
Power Factor
1.0 1.0
1.0
:Battery
12Volis7Gr(66 11540 CC A Minimum kGroup 35AGM 65D.CCAMin1mum ." -•
�466211
Unit Weight(lb/k9)
406/186 448/203
x25x29/1218x638x732
v
'°--
Sound output in dB(A) at 23 it(7 m) with generator operating at normal load"
66 66
61
i5ound outputln AB(�A)z1230Qm)wiU Oen_eralor in bme_t%st Icw speed ereicise mode;
-
38 '_ v�,,`,z-; ,, 58.,.
-
-,_;-jz58 _+c
Fxerdse duration
5 min 5 min
5 min
Engine
GENERAC G-Force 1000 Series
till CapaiiN!ncludingRltef`2;_�`�.,Y. ,;. :7 ApProx. lug yVl B,L m_ "APProx19GV18L.. ,.��3AP,pimi14gV16L..;"
Operating ram 3.600 3.600 3,600
a mercury) for natural gas,10-12• water column (19-22 min mercury)
37.26(NG1
Controls
SaleN Fu$ed/Fpse Problem Protection ` = .. -,
- - Standard ,.
Automatic Low Oil Pressure/High Oil Temperature Shutdown
Standard
0v'ercanlVOderspied;(@ 72 Hz)/rpm sense Loss shNtlown-� - ' -
,v Standard
High Engine Temperature Shutdown
Standard
Internid FaultMcolject Wiring Protection _. _ _ " - ;.
, " Standard
Common External Faul(CapabiliN
Standard
flelU Upy2dable Flirilware - _.
- Standard J,_
—Sound leveBare been Wm me bool of the genov". Saved levektalsn loom ado sides door gmeratmmaybe hinel depending oninsDlladon puaneters.Azting defritions- Sunday Apptcaak on spplyng emergenr/powerfor Netlwalion
of Ne Mlay pw.a udage.No mredoad rapabilry isaniUb@for OAs afvip.(AgeWgsloaccwdmo iIhM514,603D453nd DN6271).•MsdmuntilorogampsaM
wimdare suNea IoanO eniletl byvmA IaGmsashml DlWmepajavle
oc i emblem momentum. aWlude. emoneemerend CWmc ce-Msanam Preen &omusabM35r<meratweach 1.000lee1(304.6meters)
aeme sea lent and alsomill macrame anoin t puardrm each 6'C(10`F) eaves 16 C(60'n.
General Information
Specifications
Generator
Model
9 kW
11 kW
16 kW
20 kW
Rated Voltage
.. 240
Rated Maximum Load
'
Current (Amps) at Rated
37.5
45.8
66.6
83.3
91.7
Voltage with LP'
Main Line Circuit Breaker
40 Amp
50 Amp
70 Amp
100 Amp
100 Amp
(Generator Disconnect)
Phase
1
Rated AC Frequency
60 Hz
Battery Requirement
12 volts, Group 26R-540CCA Minimum or Group 35AGM-65OCCA Minimum
(Field supplied)
(see Replacement Parts)
Enclosure
Aluminum
Weight (lbs/kilos)
3401154
348/158
409/186
448/203
466/211
(without battery)
This unit is tested in accordance to UL 2200 standards with an operating temperature of -20 °F (-29 °C) to 122 °F
Normal Operating Range
(50'C). For areas where temperatures fall below 32'F (0 °C) a cold weather kit is recommended. When operated
above 77 °F (25 °C) there may be a decrease in engine power. See Engine.
These generators are rated in accordance with UL 2200, Safely Standard for Stationary Engine Generator Assemblies, and CSA-C22.2 No. 100-04
Standard for Motors and Generators.
Natural Gas ratings will depend on specific fuel joules/BTU content. Typical derales are between 10-20% off the LP gas rating.
Engine
Model
9 kW
11 kW
16/20/22 kW
Type of Engine
GH426
GTH-530
GT-999
Number of Cylinders
1
2
2
Displacement
426 cc
530 cc
999 cc
Cylinder Block
Aluminum w/ cast iron sleeve
Recommended Spark Plug
See Replacement Parts
Spark Plug Gap
0.020 in (0.508 mm)
0.030 in (0.76 mm)
0.040 in (1.02 mm)
Valve Clearance
0.002-0.004 in
(0.05-0.1 mm)
0.002-0.004 in
(0.05-0.1 mm)
0.002-0.004 in
(0.05-0.1 mm)
Starter
12 VDC
Oil Capacity Including Filter
Approx. 1.1 qt (1.03 L)
Approx. 1.7 qt (1.6 L)
Approx. 1.9 qt (1.8 L)
Recommended Oil Filter
See Replacement Parts
Recommended Air Filter
See Replacement Parts
Engine power is subject to and limited by such factors as fuel BTUfjoules, ambient temperature and altitude. Engine power decreases about 3.5% for
each 1000 ft (304.8 m) above sea level, and also will decrease about 1% for each 10 °F (6 °C) above 50 °F (15 °C) ambient temperature.
The specification sheet for your generator was included in the documentation provided with the unit at the time of
purchase. For additional copies, consult your local Independent Authorized Service Dealer (IASD) for your specific
generator model.
Owner's Manual for 60 Hz Air -Cooled Generators
Automatic
Transfer Switches
Description
Service and non -Service rated
Automatic Smart Transfer Switches
100 - 400 Amps, Single Phase
G @us
Q
LISTED
'CnL only applies to non -service rated switches
Generac Automatic Transfer Switches are designed for use with single phase generators that utilize an Evolution'" or Nexus"
Controller. The 100, 200, and 400 amp open transition switches are available in single phase in both service equipment rated and
non -service equipment rated configurations. The 150 and 300 amp open transition switches are only available in a service rated
equipment configuration.
Standard Features
Service rated (RXSW) Generac Automatic Transfer Switches are housed in an aluminum NEMA/UL Type 3R enclosure*, with
electrostatically applied and baked powder paint. The Heavy Duty Generac Contactor is a UL recognized device, designed for
years of service. The controller at the generator handles all the timing, sensing, exercising functions, and transfer commands. All
switches are covered by a 5 year limited warranty.
Non -service rated (RXSC) switches are housed in a steel enclosure.
DPM Technology
Through the use of digital power technology (DPM), these switches have the capability to manage up to 4 individual HVAC (24 VAC
controlled) loads with no additional hardware. When used in tandem with Smart Management Modules, up to S more loads can be
managed as well, providing the most installation efficient power management options available.
R1_ a!,
O
a r�ooa
100-400 Amps, Single Phase
Functions
All timing and sensing functions originate in the generator controller
Automatic Smart Transfer Switches
Utilityvoltage drop-out......................................................................................................................................................................................................................<65%
Timer to generator start ..................................................................................................
10 second factory set, adjustable between 2-1500 seconds by a qualified dealer'
Enginewarm up delay.................................................................................................................................................................................................................
5 seconds
Standbyvoltage sensor..................................................................................................................................................................................................
65% for 5 seconds
Utilityvoltage pickup ................... .............................................
...................................................... ................................. .................................................................. >80%
Re -transfer time delay...............................................................................................................................................................................................................
15 seconds
Enginecool -down timer.........................................................................................................--...............................................................................................
60 seconds
Exerciser..............................................................................................................................................................5
or 12 minutes adjustable weekly/Bi-weekly/Monthly"
The transfer switch can he operated manually without power applied.
'When used in conjunction with units utilizing Evolution'" controls "Adjustable via the controller
Specifications
Model
RXSC10OA3
RXSW100A3
RXSW15OA3
RXSG200A3
RXSW2COA3
RXSW30OA3
RXSC4c0A3
RKSW400A3
Amps
100
100
ISO
200
200
300
400
400
Voltage
120240, 10
120/240, 10
120/240, to
120/240, 1e
120/240, 10
120/240, 10
120/240, 10
120/240, to
Wad Transition Type
(Automatic)
Open Transition
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Service Rated
Open Transition
Service Rated
Open Transition
Open Transition
Service Rated
Enclosure Type
NEMA/l1L 311
NEMA/UL 311
NEMA/UL 311
NEMA/UL 311
NENIA(UL 311
NEf"L 311
NEMA/UL 311
NEMA/UL 3R
UL Rating
UL/CUL
UL
UL
UUCUL
UL
UL
UL/CUL
UL
Withstand Rating
(Amps)
10,000
10,000
22.000
10,000
22,000
22,000
22,000
22,000
Wg Range
1/0-#14
250 MCM-#6
600 MCM-#4 or 1/0-250 MCM
Dimensions
Model
RXSC100A3
RXSW100A3
RXSW15043
RXSC200A3
RXSW20OA3
RXSW30043
RXSC400A3
RXSW409A3
Height
H1
17.241437.9
17.24/437.9
26.75/679.4
17,24/437.9
26.75/679A
42.91/1089.9
31.25/793.8
42.91/1089.9
(InJmm)
H2
20/508
20/508
3DR62
20/508
30/762
4110219.2
3014.4
48/1219.2
Width
W1
12.5/317.5
12.51317.5
10.5/266.7
12.5/317.5
10.5266.7
16.69/423.9
19.18/487.2
16.691423.9
gnJmm)
W2
14.6/370.8
14.6/370.8
13.5/342.9
14.6/3708
13.5/342.9
21.82/554.2
24/fi09.6
21.82/554.2
Depth HnJmm)
7.09/180.1
7.09/180.1
6.3/tE0:1
7.09/180.1
6.3/160.1
10.u6255.5
10.0fi/255.5
10.0605.5
Weight HtAAlos)
20/9.07
22.5/10.21
39/t Z69
20/9.07
39/17.69
140/63.5
133/fi0.33
140/63.5
Hz
xt
�DEPTH
--w2 —I
GENERAC' Generac Power systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI53189 - generac.com
02017 Generac Power Stems, Me. An rights reserved. An secilkaeons are subject to change wbhout nonce. Bugeon 1DODDD13459-A 04/24/17