Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
-FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE TIQE GRAND CARLTON
Builder Name: WYNNE BUILDING COPR.
SGANNM
Street: VX \5 rr�, JCjq
Permit Office: ST. LUCIE COUNTY
BYP
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner. WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
l
St. Luce V®i.)�il
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. WA
R= ft2
4. Number of Bedrooms 2
d. NIA
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1446.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1446.00 ft'
6. Conditioned floor area above grade (ft2) 1446
b. N/A
R= ft'
Conditioned floor area below grade (ft') 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor: SgI, U=0.36 101.25 ft2
SHGC: SHGC=0.25
b. U-Factor. SgI, U=0.65 40.00 ft2
12. Coaling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
_
kBtu/hr Efficiency
d. U-Factor: NIA ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.239
14. Hot water systems
8. Floor Types (1445.5 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Patel
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.18
PASS
Total Baseline Loads: 48.09
I hereby certify that the plans and specifications covered by
Review of the plans and
THE Sp9r8
this calculation are in compliance with the Florida Energy
specifications covered by this
Of
, _ OVO
Code.
calculation indicates compliance
f,',;;' °„ <O
with the Florida Energy Code.
F uu,G"l •;-
PREPAREDBefore
construction is completed
r
DATE:
this building will be inspected for
compliance with Section 553.908
* o
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
Florida Statutes.
G'Op
WE
OWNERJ�k�N�;
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
11/8/2018 3:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE GRAND CARL
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR.
Rotate Angle: 180
Street:
permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family. Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
J
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1446 11568
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 301
2408 No
0
1
1 Yes
Yes
Yes
2 WIC 63
504 No
0
1 No
Yes
Yes
3 M. BATH 56
448 No
0
1 Yes
Yes
Yes
4 KITCHEN 192
1536 Yes
0
1 No
Yes
Yes
5 BATH 45
360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2 204
1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY 55
440 No
0
1 Yes
Yes
Yes
8 LAUNDRY 42
336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING 488
3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
301 ft'
__
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft'
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft'
0 1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft'
___
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ft'
--
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ft'
__
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft 0
55 ft'
0 1
0
11/8/2018 3:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY Eft
0
42 ft'
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft'
0
1
0
ROOF
- / Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1524 ft'
240 ft'
Light
0.6
No
0.9
No
0
18.4
ATTIC
J#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft'
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
-
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft'
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft'
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft'
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 fC'
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft'
0.1
Wood
6 Under Attic (Vented) BEDROOM
30
Blown
204 ft'
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft'
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft'
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft'
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar
Below
0
1 NE=>SW Exterior Concrete Block - Ext Ins(BEDROOM
4.1 10
0 8
0
80.0 ft'
0
0
0.6
0
2 SW=>NE Exterior Concrete Block - Ext Ins(BEDROOM
4.1 28
0 8
0
224.0 ft'
0
0
0.6
0
3 NW=>SE Exterior Concrete Block - Ext Ins(BEDROOM
4.1 14
0 8
0
112.0 ft'
0
0
0.6
0
4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft'
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft'
0
0
0.6
0
6 NE=>SW Exterior Concrete Block - Ext InREDROOM 2
4.1 16
0 8
0
128.0 ft'
0
6
0.6
0
7 SE=>NW Exterior Concrete Block - Fact InQEDROOM 2
4.1 10
0 8
0
80.0 fe
0
0
0.6
0
8 S=>N Exterior Concrete Block - Ext InflEDROOM 2
4.1 4
3 8
0
34.0 it'
0
0
0.6
0
9 SW=>NE Exterior Concrete Block - Ext IndaEDROOM 2
4.1 2
0 8
0
16.0 ft'
0
0
0.6
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft'
0
0
0.6
0
_11 SW=>NE Exterior Concrete Block - Fitt Insul ENTRY
4.1 1
0 8
0
8.0 ft'
0
0
0.6
0
12 SW=>NE Exterior Concrete Block - Ext InsdIAUNDRY
4.1 6 '
0 8
0
48.0 ft'
0
0
0.6
0
13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI
4.1 26
0 8
0
208.0 ft'
0
0
0.6
0
_14 NW=>SE Exterior Concrete Block -Ext In53REAT/DINI
4.1 20
0 8
0
160.0 ft'
0
0
0.6
0
_15 N=>S Garage Frame -Wood KITCHEN
11 24
8
192.0 IF
0.23
0.6
0
11/8/2018 3:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page3 of 5
F6RM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DOORS
# Ornt
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall
V # Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
0.36 0.25 N 32.9 ft2 1 ft 0 in 1 It 4 in
0.36 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in
0.36 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in
0.36 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in
0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft4 in
Drapesiblinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315 ft2
315 ft2
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000366
1349.6 74.09 139.34 .2578
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 1534.8 kBtuthr cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
11/8/2018 3:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
DUCTS
_ / — Supply
—
—
Return —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic 6
250 ft'
Attic
65 ft'
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programabl[e
Cr[eiling Fans:
]Thermostarxt:,]Y
Heating [X] Jan Feb
Mar
r
APf
May
[[ ]]
[X] Jun
(X�
[ ]Jul
(X]Dee
[ ]Aug
[[ ]]
[X] Sep
[ j ([X��
L J
H
[NovrX'j
Venting [[ ]] Jan [) Feb
L l
X Mar
l
I
[[ 11 Jun
[ ] Jul
I 1 Aug
[( ]] Sep
Lxl Oct
Nov
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (VVEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft'
0 ft
0.3
BEDROOM
'
Default(8 lbs/sq.ft.
ft'
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft'
ft
0.3
M. BATH
Default(81bs/sq.ft.
ft'
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft'
ft
0.3
BATH
Default(B Ibs/sq.ft.
ft'
ft
0.3
BEDROOM 2
Default(8 lbs/sq.ft.
ft'
ft
0.3
ENTRY
Default(8lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
Default(8 Ibs/s .ft.
ft'
ft
0.3
GREAT/DINING
Name: Test Rater
Rating Compant: Test Rater
Date: I 1'-1 -q
11/8/2018 3:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5
2017 — AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
w
Design Location: FL, Fort Pierce
c=i
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the lop plate and the,top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninino and wirino
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire Rnrinkler cover nlateg and walls or ceilinas
. ,,, auun, „�Vo. ,U„ .,, ,oy weus snail ue m accoroanoe wim me Provisions or iw UU.
11/8/2018 3:28 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location 8 insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/Water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1446
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.442
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.239
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. \ l C�
Builder Signature: Date: � `` s- \
Address of New HomeN \ ��� 9 City/FL Zip: - . P ERe&,-FL ��.��'
7,��tJ�
11/8/2018 3:28:28 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
wrightsoft, Project Summa Job:
Entire House DDate:
QUICK.CALCS, INC.
For. THE GRAND CARLTON SGANNF-dJ
WYNNE D ELOPMENT, FT. PIERCE, FL BY
Notes: \� M �lj C1 St. Lucie C ouriV
Weather. Fort Pierce, FL, US
Winter Design. Conditions
Summer Design Conditions
Outside db 42 OF
Outside db
90 OF
Inside db 70 OF
Inside db
75 OF
Design TD 28 OF
Des gn TD
15 OF
Daily range
L
Relative humidity
50 %
Moisture difference
61 gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 17848 Btuh
Structure
17520 Btuh
Ducts 5654 Btuh
Central vent (0 cfm) 0 Btuh
Ducts
Central vent (0 cfm)
8536 Btuh
0 Btuh
e)
Humnone
idification 0 Btuh
Blowner
0 Btuh
Piping 0 Btuh
Equipment load 23503 Btuh
Use manufacturer's data
n
Infiltration
Ratelswingg multipplier
Equipment sensible load
0.95
24753 Btuh
Method Simplified
Construction quality Average
Latent Cooling Equipment_Load Sizing
Fireplaces 0
Structure
3203 Btuh
Ducts
2318 Btuh
Central vent (0 cfm)
0 Btuh '
Heatingg Cool ingg
Area
(none)
(ft-) 1446 1446
Equipment latent load
5521 Btuh
Volume (W) 12511 12511
Airchanges/hour 0.45 0.23
Equipment total load
30274 Btuh
Equiv. AVF (cfm) 94 48
Req, total capacity at 0.70 SHR
2.9 ton
Heating Equipment Summary
Cooling Equipment
Summary
Make Canner
Trade CARRIER AIR CONDITIONING
Model 25HBC536A•030
AHRI ref 7914585
8.5 HSPF
34600 Btuh @ 47OF
27 OF
1160 cfm
0.049 cfm/Btuh
0.50 in H2O
=32OF
Backup:
Input = 7 kW, Output = 23009 Btuh, 100 AFUE
Make Carrier
Trade CARRIER AIR CONDITIONING
Cond 25HBC53WO30
Coil FX4DN(B,F)037
AHRI ref 791
Efficiency 12.0 EER, 15'SEER
Sensiblecooling
24360
Btuh
Latent cooling
10440
Btuh
Total cooling
34800'
Btuh
Actual -airflow
1160
cfm
Air flow factor
0.045
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.83
Calculations approved byACCA to meet all requirements of Manual J Sth Ed
�. + wrightsofL' Right-Sufte® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38
Pa
...uick Page GRAND CARLTON-1448aup Calc = MJ8 Front Door Faces: N ge 1
wrightsoft, Right.J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LK, FT. PIERCE, FL 34-946 Phone: 772-466-6799 Fax 77246"796 Emil; QUICKCALCS@AOLCOM
1
Room name
Entire House
BEDROOM
2
F4osed wall
156.2 ft
49.0 it
3
Room height
8.7 It d
8.0 0 heat/cool
4
Room dimensions
1.0 x 297.0 it
5
Room area
1446.6 ft'
297.0 ft-
Ty
Construction
U-value
Or
HTM
Area
Load
s (')
Load
number
(Btuh/WF)
(Btulvft�
or perimeter (it)
(Btuh)
or perimeter (ft)
(Btuh) .
Heat
Cool
Gross
NIPIS
Heat
Cool
Gmss
WP/S
Heat
Cool
8
t
.13A4ocs
..0143
d•
` 400
:.: 2.55
503
- 465
, ;. 18M
-. 1184
72
72
288
-.... 183
L�G-
-4A5.2&M7
0.770
h'
21.56
` ' 19.31
. 38
..:. 0
- ` 815
i 730,
: ' 0
' 0
d 0
'' 0
V)I
13A4ocs
0.143
a
4.00
255
128
83
333
212
0
0
0
..:-.
0
I�----GD
1Aatwn
1.270
a
35.56
87.29
24
2
848
2082
0
0
0
0
11
11DO
0.390
a
10.92
11.31
21
21
229
238
0
0
0
0
W - -
:13A4ocs
0.143
se
4.00
255
- 34
34
136
86
- 0
- 0
- 61
0
W
13A4ocs
0.143
s
4.00
255
360
353
1414
899
216
216
865
550
-a
1Aclom
1.270
s
35.56
34.77
7
7
247
241
0
0
0
0
13A4ocs
0.143
w
400
255
310
237
949
. 603.
104
72
288
183
'
1Acl m -. .
_ .. 1.270
w
35:56
55.21
32
: - 2
- -1140
- 4770
- 82
-2
`. 1140
1770.
'4AS26m a . •. -
.0.770
. w'
21.56
' :,19.31
41
. 41
' 880
:' 788
• .. 0,
0
, ` 0
.. 5,. 0
P
12C-0sw
0.091
-
255
1.28
192
192
489
246
0
0
0
0
C'1 ,.
_16A3Uoa-
- 0.032
- -
- 0.90
; 232
-. 1446
•1 1446
- 1295
:, 8354
-.297
,- •. 297
. '266
1-. %:689
F
22htd
0.989
-
27.69
0.00
1446
156
4325
0
297
49
1.357
0
6
c)AED excursion
918
627
Em,dope loss/gain
14961
13349
4204
4D03
12
a) Infiltration
2887
791
848
232
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
6
1380
3
690
Applianceslother
20M
0
Subtotal Qinas 6 to 13)
17848
17520
5053
4925
Less edemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
17M
17520
5053
4925
15
Duct loads
32%
49% 1
W54
85W
32%
49%
1601
2400
Total room load
235503
26056
6%
73P5
Air reored(cfm)
1160
1160
328
326
,4g& -"I-- wrilghts fir Right -Suite® Universal 201717.0.14 RSU08101
...uick Calcs\Documents\THE GRAND CARLTO&1446.mp Calc = MJ8 Front Doorfaces:
2017-Apr-11 09:29:38
Page 1
► + wrightsoft- Right-M Worksheet Job:
Entire House Dato:
QUICK CALCS, INC. By:
317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOLCOM
1
Room name
WIC
KITCHEN
adwall
Oft
Oft
3
R height
8.0 it heaVcool
8.0 it heaticool
4
Room dimensions
6.0 x 9.0 it
1.0 x 1720 ft
5
Room area
54.0 ft2
172.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (111
number
(Stuh/fti°F)
(BtulJft2)
or perimeter (it)
(Btuh)
or perimeter (it)
(Bt�uh)
Heat
Cool
Gross
I WP/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
--13A-0ocs-,`
�:
.'-0143
,-
;-n
4.00
,- 2.55
0,
-., 0.
0}
-.'0.
-0,
0',
0'-
0
4A5-2om ` .;
.0770
:' n:
"21.56
` 19.31
... 0
. , 0
0
... 0
..... 0
. . 0
,... ' ...0
:- •. r0
lN--G
13A-4ocs
0.143
a
4.00
2.55
0
0
0
0
0
0
0
0
1Actan
1.270
a
35.56
87.29
0
0
0
0
0
0
0
0
11DO
0.390
a
10.92
11.31
0
0
0
0
0
0
0
0
W- -
slak locs
0.143
se
4.00
255
0
0
0
0
- 0
0
- 0
0
W
13A-0ocs
0.143
s
4.00
255
0
0
0
0
0
0
0
0
1Aciwn
1.270
s
35.56
34.77
0
0
0
0
0
0
0
0
13A4ocs
0.143
w
400
255
0
0
a
0
0
0.
0
=. '0
`1Ac1cm
1.270
w
-3556
55.21
0
0
0
- 0-
0
0..
0
:0
_4A5-tom ;.'.
.0.770
' w
. '21.56
,. -19:31
�- . . 0
-. 0,:
-_. 0
'.0
'0
.. .0
;:.: - 0
...: ` ..> .0
P
12C-0sw
0.091
-
265
1.28
0
0
0
0
64
.
64
163
82
C.. _
16A30md ..
-0.032+>-
'. .0.90
°' 232"
'54
.. 54
48
'125
172
--172
i' 164
_. ::.':399
F
22A-1pl
0.989
-
27.69
0.00
54
0
0
0
172
.
0
_
0
0
6
c)AED exaasion
-9
-170
Envelope loss/gain
48
117
317
311
12
a) IMBration
0
0
0
0
b) Roomventilation
0
0
0
0
13
Internal gains: Occupants aQ 230
0
0
0
0
Applianceslother
0
2000
Subtotal pines 6 to 13)
48
117
317
2311
emal load
0
0
0
0
sfer
0
0
0
0
ution
0
0
0
EAlr.q
4s
117
317
317
.0
32%
49°/,
15
57
32%
49%
1126ds
1126n
loatl
64
174
4183%ed
(cfm)
3
8
21
153
A -F'+ Wrightsoftr Right -Suite® Universal 201717.0.14 RSU08101
...uick CalesWocumentslTHE GRAND CARLTON-1446.mp Calc = MJ8 Front Door faces:
2017-Apr11 09:29:38
Page 2
+ wrightsoft RighW@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466a796 Email: QUICKCALCS@AOL.COM
1
2
3
4
5
Room name
FVosed wall
Room height
Room dimensions
Room area
BATH
8.0 ft 5.0 ft
heat/cool
9.0 x 5.0 ft
45.0 ft-
BEDROOM 2
2 ft
8.0 It heat/cool
1.0 x 203.5 ft
203.5 ft'
Ty
Construction
number
U-value
(BtutVfti°F)
Or
HTM
(Btuwft9
Area
or perimeter (ft)
(Btuh)
Am
or perimeter (ft)
(Bt�uh)
Heat
Owl
Gross
N/PIS
Heat
Cool
Gross
I WP/S
Heat
Cool
6
11
47f
=-G:
13A4ocs ;. _
'4AS-20M- .
13A4acs
1Aoiom
11D0
.1344=-
13A4ccs
.1A-c1=
�13A4acs -
1Aolorh -,.
:4A5-tom ,'
12COsw
22A-ta
0143
0.710'n.
0.143
1.270
0.390
0.143.
0.143
1270
0143
1 27o
'.0.770
0.091
0.032
0.989
n--
a
a
a
se
s
s
w
w :
W
-
.-
-
• 400
721.56
4.00
35.56
10.92
4.00
4.00
3556
400
.3556
:221.56
2,55
..0.90
27.69
2,55
:%. 19.31
255
97.29
11.31
255
255
34.77
2.55
. .55.21
.18:31
1.28
- 232'
0.00
40
:_, .'0,:-.
0
0
0
0
0
0
0^
0
f- 0'
0
- 45
45
40
.,a
0
0
0
.0
0
0
0
o
0---:.
0
45
5
.. 160
o..
0
0
0
- 0
0
0
0
0
o'
0
.:40
138
102
0
0
0
0
0
0
0
0
- .: 0:
.o
0
104,
0-
128
'0
80
24
0
. 34
32
0
0
0
0
-0
:204
204
_' 128.-
.0-`n
56
2
0
.34
32
0
. 0.
-0'".
0:
0
204,
34
513
0..
225
848
0
136
128
0
0
o
.- .. o..,
0
.182
. ..946.
.:.. 326
.. :'0
143
2082
0
86
81
0
0
.. . 0
`= .:. U
0
-:: :472
... 0
IF------GD
W -
P
C :?'J6A30ind'
F
6
c)AED excursion
_16
-85
Envelope loss/gain
339
190
2978
3106
12
a) trdltration
b) Room ventilation
87
0
24
0
593
0
162
0
13
Internal gains: Occupants Q 230
Appliance.4other
0
0
0
1
230
0
Subtotal (lines 6 to 13)
425
214
3571
3498
s e#emal load
0
0
0
0
Es fe0
tdbu8an
j14,u,.btt.,
tal4252143571
cloads32%
49%
0
135
0
0
104
32%
49%
0
0
1131
0
0
3498
1704
momload
(cfm)
560318
28
14
4702reuired
232
232
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
JJ- wrightsoR• 2017-Apr-11 09:29:38
flec-Fk RlghtSuite@ Universa1.201717.0.14 RSU08101 Page 3
...ulck CalcMDocumentslTHE GRAND CARLTON-1446.mp Calc=MJ8 Front Doorfaces: N
wrightsoft• Right-M Worksheet Date:
Entire House
QUICK CALCS, INC. By.
317 ST. LUCIE I.M. FT. PIERCE, FL 34946Phone: 772-46M799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
LAUNDRY
GREAT/DINING
2
Famed wall
6.0 it
47.0 It
3
Room height
8.0 It heal/cool
9.8 ft heaticool
4
Room dimensions
7.0 x 6.0 It
1.0 x 526.0 ft
5
Room area
420 W
526.0 ft-
Ty
Construction
U-vatue
Or
HTM
Area (ft')
Load
Area I
Load
number
(BtuWftx°F)
(BtuWft')
or perimeter (ft)
Pull)
a perimeter (ft)
(Stuh)
Heat
Copl
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
W
AM46cs
.'_0143
n',
'-�• 400
-.. 755
-.'0
0
0
:- . :.0
.. 255
r: 217:"
-' 869
552
1==G;
.4P i2am % ..'
_0 770
nor
.. 21:56
19.31
-- :0
- -0
:.. _ 0
.38
'- " 0.
815
,.;
'.730
ly
13A-4=
0.143
a
4.00
255
0
0
0
_'0
0
0
0
0
0
1Actom
1.270
a
35.55
97.29
0
0
0
0
0
0
0
0
11
II-----GD
11DO
0.390
a
10.92
11.31
0
0
0
0
0
0
0
0
W
-13A4=
0:143
se
.4.00
255
0
0
0
0
0
0-
0
0
N/
13A-4=
0.143
s
4.00
265
48
48
192
122
0
0
0
0
I--t'
1Aclom
1270
s
3556
34.77
0
0
0
0
0
0
0
0
A?V_13A,46cs
0143
w
.. 4.00
2.55
0
0
0
0
206-
165
66f
420
JAa1om',
1270
w.
35.56-
5521
.0
0
- 0
'0
A'
-0';
- 0
s-0
4A54ah=_
0.770.
W:-
.21:56
- • 19.31
.. 0
-0
.:. ..0
-: 0
' ,.. 41
` 880.
':. '788
P „
12C-0sw
0.091
--
255
1.28
56
56
143
72
0
...41
0
0
0
C :;
„16A•30md..
0.032,
-'
. 0.90
232'.
42
-42
, 38
': 97
.. -526
526
.: 471
-..1220
F.
22A-tpl
0.989
-
27.69
0.00
42
6
166
0
526
47
1302
,.:
0
6
a)AED excursion
_22
668
Envelope loss/gain
639
270
4997
4379
12
a) Infiltration
104
28
997
273
b) Roomvemilation
0
0
0
0
13
Internal gains: Occupants @ 23D
0
0
2
4fi0
Applianceslother
0
0
Subtotal (Iir es 6 to 13)
643
298
5994
5112
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
643
298
5994
5112
15
Duct loads
32-1
49%
204
145
321/6
490/6
1899
2490
Total room load
7�
Air required(cfm)
0
3�90
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
wrightsOft- 2017-Apr-11 09:29:38
A Right -Suite® Universal 201717.0.14 RSU08101 Page 4
...uick CalcsWocuments\THE GRAND CARLTON-1446.mp Cato = MJ8 Front Door faces: N
wrightsoft- Right-M Worksheet Job:
Entire House Date:
QUICK CAMS, INC. By:
317 ST. LUCIE I.M. FT PIERCE, FL 34946 Phone: 772-4666799 Fax: 772466-6798 Email: OUCKCALOROA01 CnM
1
Room name
FOYER
M. BATH
2
=ad wall
7.0 it
8.0 ft
3
height
&0 It heaVcoo[
8.0 ft heat/cool
4
Room dimensions
1.0 x 50.0 ft
7.0 x 8.0 It
6
Room area
50.0 ft2
56.0 ft2
Ty
Construction
U-value
Or
HTM
Area (M
Load
Area
Load
number
BtuWft-F)
(Btulvft-)
a perimeter (ft)
meter
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cl
Gross
NIR/S
Heat
Cool
Once.
NIPIS
Heat
Cool
6
O.M
400
2 56
8
132::�
20
0
G
4A5-2om
.03M
n
21'56
A9F311
0
-0
0
;0
0-
0,
0
13A4=
0.143
e
4.00
2.55
48
27
108
69
0
0
0
0
1A-cl=
1.270
e
35.56
97.29
0
0
0
0
0
0
0
0
1
D
11DO
0.390
e
10.92
11.31
21
21
229
238
0
0
0
0
w -
-13A4ocs
0:143
as
4.00
2.55
0
0
01
0
0
0
0
0
13A-4ccs
0.143
a
4.00
255
0
0
0
0
64
67
228
145
1Ac1cm
1.270
s
35.56
34.77
0
0
0
0
7
7
247
241
13AAocs
0.143
w
4.00
255
0
0
0
�0
0
0
0
- 0
1Asciorn-
1270
w
35.56
-21.56
55.21
D.x
0
0
0
0
0
o',
->o
QT70
-W
1
'19.31
�0
0:�
0
0
0
0
0
-n-o
P,
12C-GSw
0 .091
-
2.55
128
72
72
183
92
0
0
0
0
C :',AA-30m&
0:032
-
.0.90
-i32
zSO
<50
45
116
-55
56
50
:. .. - 130
F
2 . 2AADI
0.9819--
27.69
0.00
50
7
194
0
55
8
222
0
%
J
6
C)AED excursion
Sq
At-
-38 j
Envelope loss/gain
792
496
747
478
12
a) Infiltration
121
33
38
b) Room ventilation
0
0
0
0
13
Intemal game: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal Pines 6 to 13)
913
529
885
616
Less eDdernal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
01
14
Subtotal
913
IM
516
is ,
Duct loads
32-1Tj/.
289
258
32%1
49%
280
251
Calculations approved bVACCA to meet all requirements of Manual-i 8th Ed.
AM wrightsaft- Rlght-SurteV Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38
... uIck CalaslDocumentskTHE GRAND CARLTON-1446.mp Colo = MJ8 Front Dow faces: N Page 5
Duct S stem Summary Date:
�- Wrightsofty ry Date:
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799: Fax 77246"796 Ema:'I: OUICKCALCS@AOLCOM
For. THE GRAND CARLTON
WYNNE DEVELOPMENT, FT. PIERCE, FL
External static pressure
Pressure losses
Available static pressure'
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.25010.250
in H2O
0.285
in1100ft
1160
cfm
Cooling
0.50
in H2O
0
in H2O
O:50
in H2O
0.250 / 0.250
in H2O
0.285
in/100ft
1160
cfm
176 ft
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(n)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h 560
28
14
0.364
4.0
0x0
VIFx
22.4
115.0
st1
BEDROOM
h 4702
232
232
0.360
7.0
OxO
VIFx
23.9
115.0
all
BEDROOM -A
h 3327
164
163
0.300
6.0
OxO
VIFx
31.8
135.0
st2
BEDROOM-B
h 3327
164
163
0.285
6.0
OxO
VIFx
40.6
135.0
st2
FOYER
h 1202
59
35
0.505
4.0
Ox0
VIFx
4.0
95.0
,GREAT/DINING
h 3946
195
169
0.300
7.0
Ox0
VIFx
31.8
135.0
st2
GREAT/DINING-A
h 3946
195
169
0.300
7.0
OxO
VIFx
31.8
135.0
st2
'KITCHEN
c 3437
21
153
0.379
6.0
OxO
VIFx
17.0
115.0
st1
LAUNDRY
h 846
42
20
0.361
4.0
OxO
VIFx
23.3
115.0
all
M. BATFFA
h 768
.58
34
0
0
OxO
VIFx
0
0
wlc
c 174
3
8
0.309
4.0
Ox0
VIFx
27.0
135.0
st2
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(In)
(in)
Material
Trunk
st2
Peak AVF
721
672
0.285
918
12.0
0 x 0
VinlFlx
st1
st1
Peak AVF
1043
1091
0:285
1020
14.0
0 x 0
VinlFlx
C WI'1 htsOTt' 2017-Apr-11 09:29:38
.it- 9 RigMSu6eO Universal2gi717.0.14 RSUD8101 Page 1
...ulck CalcslDocumentS1THE GRAND CARLTON-1446.mp Calc=MJB Front Doorfaces: N
Name
Grille
Size (in)
Htg,
(cfm)
Cig
(Cfm) 1
TEL
(ft)
Design
FR
Veloc
I (fpm)
Diam
I (in)
H x W
I (n)
Stud/Joist
I Opening (in)
Duct
Matl
Trunk
rb1
Ox0
1 1160
1160
0
1 0
0
0
Ox 0
1
VIFx
Awri htsoft' 2017-Apt-fl 09:29:38
9 RightSuOe® Universal 2017 17.0.14 RSU08101 Page 2
...ulck CalcslDocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N