HomeMy WebLinkAboutREVISIONS - BUILDING PERMITOFFICE USE ONLY:
DATE FILED: _
REVISION FEE:
1.
2.
LOCATION/SITE _ERMOSA
ADDRESS: 1Z tl
PERMIT # 1905-0359
RECEIPT #
PLANNING & DEVELOPMENT SERVICES SCANNED
BUILDING & CODE REGULATION DIVISION
2300 VMGINIA AVENUE BY
FORT PIERCE, FL 34982-5652 St. Lucie County
(772) 462-1553 FAX (772) 462-1578
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
U-FACTOR ON ENERGY CALCS WAS INCORRECT AND NEEDED TO BE CHANGED
3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: ST. LECIE COUNTY CERT. #: 8898
BUSINESS NAME: Corpora ion
QUALIFIERS NAMED South U Suite ADDRESS: 8U0 wy.
CITY; Fort Nt. Lucie STATE: FL ZIP:
PHONE (DAYTIME): - FAX: 772 87 -7 56
4. OWNER/BUILDER INFORMATION:
-NAME: Wynne Building Corporation
5.
ADDRESS:
CITY:
PHONE:
ARCHITECT/ENGINEER INFORMATION:
J I Arh:
FAX: (772)878-7656
NAME: BRADEN & BRADEN
ADDRESS:
CITY: STUART STATE: FL ZIP: 34996
PHONE (DAYTIME): (772) 287-8258 FAX:
Revised 07/22=4 File ,("Copy
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE STERLING NON IMPACT
Builder Name: WYNNE DEVELOPMENT
Street: THE STERLING
Permit Office: ST. LUCIE COUNTY
. City, State, Zip: FT. PIE CE , FL,
Permit Number:
Owner. \'�,
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1 New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft'
b. Frame - Wood, Adjacent
R=11.0 192.00 ft'
3. Number of units, if multiple family 1
c. N/A
R= ft'
4. Number of Bedrooms 2
d. N/A
R= ft'
5. Is this a worst rase? Yes
10. Ceiling Types (1474.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1474.00 ftz
6. Conditioned floor area above grade (ft') 1474
b. N/A
R= ft'
Conditioned floor area below grade (ft') 0
c. NIA
R= ft
11. Ducts
R ft'
7. Windows(141.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 275
a. U-Factor: Sgl, U=0.54 101.25 ft'
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor. N/A ft'
SHGC:
13. Heating systems
kBtulhr Efficiency
d. U-Factor: N/A ft'
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted. Average SHGC: 0.250
14. Hot water systems
6. Floor Types (1473.5 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft'
b. Conservation features
EF: 0.970
b. N/A R= ft'
None
c. N/A R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 45.73
PASS
Total Baseline
Loads: 48.47
1 hereby certify that the plans and specifications covered by
Review of the plans and
STgl�
this calculation are in compliance with the Florida Energy
specifications covered by this
OFgtiE
Code.
calculation indicates compliance
ykr,,,gqaa', tC
a
n
with the Florida Energy Code.
!: rnu <fw; .',•;•;.`•',.;,• D
PREPA D BY: �X
Before construction is completed
r d
DATE: -(�
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
G'Op WE
OWNERlAGF,R17:\ ��
BUILDING OFFICIAL:
DATE: ��11 \\��22SS\\
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air #ndlooJ,certified factory -sealed in accordance with R403.3.2.1.- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordan��ojec requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R4CIMPLIANCE
ST, LUCIE CO,�U1�lT�fZ�('G
BOCC
9/13/2019 9:16 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE STERLING NO Bedrooms: 2
Address Type:
Street Address
Building Type: User Conditioned Area: 1474
Lot #
Owner Name: Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180
Street:
THE STERLING
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
'Jurisdiction: Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1474 11792
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 BEDROOM 329 2632 No
0
1
1 Yes
Yes
Yes
2 WIC 63 504 No
0
1 No
Yes
Yes
3 M.BATH 56 448 No
0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes
0
1 No
Yes
Yes
5 BATH 45 360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No
0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
329 ft'
0 1
0
2SIab-On-Grade Edge Insulatio WIC 1 ft 0
63 ft'
-_
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 ft
—_
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0
192 ft'
0 1
0
5SIab-On-Grade Edge Insulatio BATH 5 ft 0
45 ft'
—
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ft'
--
0 1
0
7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0
55 ft'
0 1
0
9/13/2019 9:16 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHFCKI_IST RFP0RT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
-
0
1
0
9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
---_
0
1
0
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1553 ft2
246 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
160
1474 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
329 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS
Adjacent Cavity Width
Space
Height
Sheathing Framing Solar
Below
a
1
NE=>SW Exterior Concrete Block - Ext Ins®EDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
2
SW=>NE Exterior Concrete Block - Ext Ins®EDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.4
0
3
NW=>SE Exterior Concrete Block - Ext Ins®EDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
4
SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
_ 5
NE=>SW Exterior Concrete Block- Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
_ 6
NE=>SW Exterior Concrete Block - Ext InfiEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
7
SE=>NW Exterior Concrete Block - Ext IndIffDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
8
S=>N Exterior Concrete Block - Ext InfiEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
_ 9
SW=>NE Exterior Concrete Block - Ext InfilEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10
SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
11
SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
12
SW=>NE Exterior Concrete Block - Ext InsdIAUNDRY
4.1 6
0 8
0
•48.0 ft2
0
0
0.4
0
_13
NE=>SW Exterior Concrete Block -Ext In59REAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
_14
NW=>SE Exterior Concrete Block -Ext Ins3REAT/DIN1
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
_15
N=>S Garage Frame -Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.4
0
9/13/2019 9:16 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DOORS
# Ornt
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1
6 8
20.6 ft'
WINDOWS
Orientation shown is the entered orientation => chancled to Worst Case.
/ Wall
V _ # Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Law-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
0.54 0.25 N 32.9 f 2 1 It 0 in 1 It 5 in
0.54 0.25 N 6.9 ft' 1 ft 0 in 1 ft 5 in
0.54 0.25 N 24.0 ft' 6 ft 0 in 1 ft 5 in
0.54 0.25 N 37.5 ft' 1 It 0 in 1 ft 5 in
0.55 0.25 N 40.0 ft' 8 It 0 in 1 It 5 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315 ft'
315 ft'
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1375.7 75.53 142.04 .1233
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
9/13/2019 9:16 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
DUCTS
_ / — Supply —
—
Return —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 275 ft'
Attic
65 ft'
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
• Programable Thermostat: Y
Ceiling Fans:Coolln
Jan Feb
Venting Jan � Feb
M:r
Mar
Apr
�
�
Junrr[[
]J
[[[[ ]]
rr[[ ]]
[[[Oct
�(]]
�
Nov]Dec
EX
X
Apr
[
May
LXl Jun
lXl Jul
[XJ Aug
LXl Sep
Occtt [X]
Nov
[ ] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft'
Oft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft'
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft'
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft'
It
0.3
BATH
Default(8 Ibs/sq.ft.
ft'
It
0.3
BEDROOM 2
Default(8 lbslsq.ft.
ft'
ft
0.3
ENTRY
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
Default(8 lbs/s.ft.
ft'
ft
0.3
GREAT/DINING
9/13/2019 9:16 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 — AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING NON IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE STERLING Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner: Jurisdiction:
_
Design Location: FL, Fort Pierce
c�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
/soffit
The insulation in an dropped ed ceiling/soffit
Y
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned spare shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
&2dltaajj��nd wiring
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
-between fire sprinkler cover rilates and walls or ceilings
a. it, auuniuu, mspecuon or iog waus span be in accorcance wnn the provisions or IGc-auu.
9/13/2019 9:16 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2 17 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 94
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5. Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1474
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.543
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250
c) Area 7c. 141.3
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
14. Heating system: Capacity 34.8
a) Split system heat pump HSPF 8.5
b) Single package heat pump HSPF
c) Electric resistance COP
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.97
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
10B1. 11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 30.0
b) Cross ventilation No
11b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: THE STERLING �� lr t�j� city/FL zip:
9/13/2019 9:16:23 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
OFFICE USE ONLY:
DATE FILED: �• �� PERMIT # / Cl O S = O 3 S 9
REVISION FEE: 60 RECEIPT. #
PLANNING & DEVELOPMENT SERVICES _
BUILDING & CODE REGULATION DIVISION
2300VI GINIAAVENUE =REUIVEDFORT PIERlE, FL 34982-5652
(772)4.62,1553 APPLICATION. F.OR BUILDING _PERMIT REVISIONPROJECTINOORMATION
LOCATION/STTE SCANNED
ADDRESS: BY
-- /Z Hee ±eS�Sw St LuciefC0uP1$g!
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
STATE:
OWNER(.BUILDER INFORMATION:
NAME:
ST. LUCIE CO CERT. #:
FAX:
CITY: STATE: �1.4
PHONE (DAYTIME: FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
PHONE• /
SLCCC 9123109
Revised 06130117 L��clov
L Pm
i ,.
FAX:
moo
wo
MB
oov
W cal °-
BRADEN & BRADEN, A. I. A., P. A. I>� -w i
W C�
IU 0
W J U
_qrckledy & 91annem
J
417 COCONUT AVENUE, STUART, FUORIOA 3499B
TELEPHONE: (772) 267-B256 FAX (772) 267-B2B3
**AAC-000032
July 2, 2019
St. Lucie County Building Department
Permit #:1905-0359
RE: 12 Hermosa
To whom it may concern,
Please note, the field revisions attached are to the electrical riser and the panel schedule to reflect whats being built in the
field. If you have any questions please feel free to call me at (772) 287-8258.
Braden & Braden AIA PA