Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE G ND CARLTON IMPACT Street: �1J��3� `��t� Builder Name: WYNNE BUILDING COPR. Permit Office: ST. LUCIE COUNTY SWUM City, State, Zip: FT. PIERCE, FL, Permit Number: 13 Owner: WYNNEBUILDINGCROP Jurisdiction: ST. LUCIE COUNTY G St. lucle Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) l� coU� ty 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= 11:2 10. Ceiling Types (1446.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade (112) 1446 b. N/A R= ft2 Conditioned floor area below grade (112) 0 c. N/A R= fta 11. Ducts R ft2 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor: Sgl, U=0.54 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor. Sgl, U=0.55 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. WA ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: i 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1445.5 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.35 PASS Total Baseline Loads: 48.09 1 hereby certify that the plans and specifications covered by Review of the plans and 4'S8E STAT this calculation are in compliance with the Florida Energy specifications covered by this0 _ ;FOB Code. calculation indicates compliance y ui,.�°!° with the Florida Energy Code. F nm PREPAR Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 0 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD WE OWNER/ ENT:• BUILDING OFFICIAL: DATE: -' `�`« DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). PT F COPY 11/18/2018 1:09 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: Uset Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M. BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 It 0 301 ft' — 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' _- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH B ft 0 56 ft' ____ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 it' 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 511 0 45 ft' -- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft' ____ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft' — 0 1 0 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Stab -On -Glade Edge Insulatio LAUNDRY Eft 0 42 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 _- 0 1 0 ROOF _ / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Fmc Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Ext Ins®EDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block- Ext Ins®EDROOM 4.1 28 0 a 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 14 0 a 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext IngffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext In!BEDROOM 2 4.1 10 0 8 0 80.0 1`1:2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext Infi&DROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 9 SW=>NE Exterior Concrete Block - Ext InII&DROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsalAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext In98REAT/DIN1 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext In98REAT/DIN1 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 11/18/2018 1:09 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DOORS # Ornt Door Type Space Stones U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.54 0.25 N 32.9 ft' 1 ft 0 in 1 ft 4 in 0.54 0.25 N 6.9 ft' 1 ft 0 in 1 It 4 in 0.64 0.25 N 24.0 ft' 6 ft 0 in 1 ft 4 in 0.54 0.25 N 37.5 ft' 1 ft 0 in 1 It 4 in 0.55 0.26 N 40.0 ft' 8 ft 0 in 1 ft 4 in Drapesiblinds None None None -Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2578 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Duds 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr dm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS — Supply — — Return — Air CFM 25 CFM25 HVAC # V # , Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft' Attic 65 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[e Thermosta[[t:��Y Ceiling Fans: HeDec ating [X] Jan [X] Feb Mar Apr May Jun [[ ]] [X] Jul ff ]] [X] Aug [[ ]] [X] Sep j [[X L Octet Nov r[X,] Venting II 11 Jan II 11 Feb X X Mar L [ Jun [[ ]] Jul [[ ]) Aug [[ ]] Sep t><1 [Xj [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibslsq.ft. 0 IF 0 ft 0.3 BEDROOM Default(8 lbslsq.ft. ft' ft 0.3 WIC Default(8 lbslsq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' It 0.3 KITCHEN Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 Ibs/sq.ft. ft' It 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' It 0.3 ENTRY Default(8 lbs/sq.ft. ft' It 0.3 LAUNDRY Default(8 lbs/s.ft. ft' ft 0.3 GREAT/DINING Name: Test Rater Rating Compant: Test Rater Signature: y►rz•W�:�.�� ►. - _ram D. 11/18/2018 1:09 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY W -Design Location: FL, Fort Pierce c=.f COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with /soffit The insulation in an dropped ed ceiling/soffit Y the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Dud shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Bs. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind poolno and worino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrin ver plates and walls or ceilinas a. In addition, inspection of log walls shall be in accordance with the provisions of IC"00. 11/18/2018 1:09 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. 1\ l Builder Signature: Date: Address New Home:� ��� �� of City/FL Zip: FT. PIERCE. FL 11118/2018 1:09:41 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 1 of 1 + wrightsofta Project Summary Entire House QUICK CALCS, INC. SCANNED Job: Date. BY By: St. Lucie County For. THE GRAND.CARLTON > WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: Weather. Fort Pierce, FL, US Winter Design Conditions. Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 . OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 . Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none e) Humidification 0 Btuh Blower 0 Btuh Piping" 0 Btuh- Equipment load 23503 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 24753 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3203 Stuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft-) 1446 1446 Equipment latent load 5521 Btuh Volume (W) Mill 12511 Air changesthour 0.45 0.23 Equipment total load 30274 Btuh Equiv. AVF (cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Caner Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A'030 Cond 25HBC536A•030 AHRI ref 7914585 Coil FX4DN(B,F)037 Efficiency 8.5 HSPF AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 470F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling , 34800 Btuh Actual airflow 1160 cfm Actual airflow 1160 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50' in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �~CA+IF wrightsoft 2o17-Apr-n 09:29:ae RightSuite® Univarsa1201717,0.14 RSU06101 - Page 1 ...uick CaleslDoc=entsME GRAND CARLMN-1446.rup Cale = MJB Front Door faces: N + wrightsoft• Right-.J@ Worksheet Job: Entire House Date: sy. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 F= 772466-6796 Email OUICKCALCS@AOLCOM 1 Room name Entire House BEDROOM 2 Exposed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft' 297.0 ft- Ty Construction U-value Or HTM Area Load Arm number (Btu)yftx°F) (Btuh/ft� or perimeter (ft) (Stuh) or perimeter (ft) (Btuh) _ Heat Cool Gross WP/S Heat Cool Gress WPIS Heat Ccol 6 : 13AAocs _t r:o 143 n " 400 ...:265 503 ;` 465 ., M, ,1184 -, 72 72: 288 ' ', ;183 4A5-20m1 .0.770 -h' °";21.56 '49.31 .38 ,...: ,0: .. 815 .' :730. _-0' 0..- A.,. `. "0 13A4ocs 0.143 a 4.00 255 128 83 333 212 0 0 0 0 1Acl m 1.270 a 35.56 8729 24 2 848 2082 0 0 0 0 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A4ccs 0.143 se 4.00 255 34 34 136 86 0 0 0 0 47/ L--G 1344acs 0.143 s 4.00 255 360 353 1414 899 216 216 865 550 1Acl m 1270 s 35.66 34.77 7 7 247 241 0 0 0 0 ,13A4acs 0.143 w 400 '255 310 237 949 603 104 72 288 183 V 1.270 ; w . - 3556 .65.21 : 32 :. 2 1140 - - .1770 . .32 2 ,".. 1140 ' - 1770 . 5-2crn ;4AS2om2; .0.770 W ' '.' 21.66 ..19.31 41, .41 880 -,- 788 0 . ..0 - 0 °:.:. 0 P 12C-0sw 0.091 - 2.55 . 1.28 192 - 192 489 246 0 0 0 0 .0 : ;16A4*d - '0.032 - = _ .0.90 i 232 1446 - .1446- '. 1295 .t . ' 3354 .297 d }. 297 - : ;266 =_ _ 09 F _ 22A-tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED erxwsion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 hemal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal (lines 6 to 13) 17848 17620 5053 4925 Less edema[ lead 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 .Subtotal 17M 17520 5053 4925 15 Duct leads 32%n 49% 5654 8636 32% 2 1601 2400 Total room lead 23503 26056 1 W53 7325 Air required(cfm) - 1160 1160 an 326 s L`A Wright soft- RightSufte® Universal 2017 17.0.14 RSUD8101 ...ulck CalcslDocuments\THE GRAND CARLTON-1446.mp Calc = MJ8 Front Door faces: 2017-Apr-11 09:29:38 Page 1 wrightsoftRighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN, FT PIERCE, FIL 34948 Phone: 772-466-6799 Fatc 772-466-6796 Email: OUICKCALCS@AOL,COM 1 Room name WIC KITCHEN 2 Exposed wall O ft O ft 3 Room height 8.0 ft heaVcoa 8.0 ft heat/cool 4 Room dimensions 6.0 x 9.0 ft 1.0 x 172-0 ft 5 Room area 54.0 ft2 172-0 W Ty Construction U-value Or HTM Area Load or number (Btuh/ft;°F) (Bluwft2) a perimeter (ft) (Btuh) perMeter (ft) (Bluth) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 .1344acs :; . ,. 40143 n - 4.00 -' `255 0 ` . 0 0 ; 0 - �0' 0';0 '.. ":0 -4AS2om` '10.770 n`-'"21.56 19.31 --...0 •,. '0 - 0- -0 .._. 0" `0 •.., .20 •'0 13A-0ocs 0.143 a 4.00 265 0 0 0 0 0 0 0 0 1Actom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 1i 11DO - 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 .W .. '13A-0ocs 0.143 se . 4.00 255 0 0 0 0 0 0 0 '. 0 W �--G 13A-4ocs 0.143 s 4.00 255 0 0 0 0 0 0 0 0 1Acian 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A4= .0.143 w 4.00 255 0 •0 0 0 0 . 0 .0 - 0 AA -clam 1.270 w'. , 35.66 - 55.21 0 0 0 D . 0 :0 - 0 .. 0 _ 4A540cn-_5. .. .0.770 w -:. '21.56 -:19.31 0 . 0 .. -.. 0 - 0 ,. 0 . .0 ::. 0 P 12C-0sw 0.091 255 1.28 0 0 0 0 64 64 163 82 C .�` 16A-30md•..' - '0.032 - 0.90 ::" 232. •54 ;-. .64 - 48 '125 : ':172 • 172 ., 154 -. •.,.399 F 22A-tpl 0.989 - 27.69 0.00 54 0 0 0 172 0 0 - 0 6 c)AED excursion -9 -170 Fmelope loss/gain 48 117 317 311 12 a) Infiltragon 0 0 0 0 b) Rcom venttlation 0 0 0 0 13 Internal gains: Occupants Qe 230 0 0 0 0 Appliances/other 0 200D Subtotal 01rres 6 to 13), 48 117 317 2311 Lis e#enal load 0 0 0 0 Less transfer 0 0 0 D Redistdbution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Due loads 32% 49% 15 67 32% 49% 100 1126 Total roam load 64 174 418 3437 Air required(cfm) 3 8 21 153 Calculations approved byACCA to meet all requirements of Manual J 8th Ed A' 'wrightSoR- 38 RlghbSuBe® Universal 201717.0.14 RSU08101 2017-ApF1109:Page 2age2 ...ulck Cales\Documents\THE GRAND CARLTON-1448.rup Cale = MJ8 Front Door faces: N t# wrightsoft Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST..LUCIE LK. FT. PIERCE. FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: OUCKCALCS@AOL.COM 1 Room name BATH BEDROOM 2 E1qosed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heaticool 8.0 ft heaUcool 4 Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 it 5 Room area 45.0 ft2 203.5 ft' Ty Construction U-v4be Or HTM Area (ft2) Load Area number I (Bt&fti°F) (Btuwft9 or perimeter (ft) (BM) or perimeter (ft) (Bluh) Heal Coal Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A4ocs 0.443 n 100 !- ; 265 40 � �40 160 , '102 �128 ', � 128 - � 513 .. B26 �V��'4A5-2om, `. _0770' m., `=2156 :.. .19.31' _ '0 ,; >0 ... 0"" . .0 0. '- 0, ':0 13A4acs 0143 a 400 2.55 0 0 0 0 .:-A' 80 56 225 143 1Aclom 1270 a 35.56 87.29 0 0 0 0 24 2 948 2082 11 �D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W .' .13A4ocs- 0.143. se .4.00 255 0 .0 0 0 34 .34 136 86 W laA4ocs 0.143 s 4,00 255 0 0 0 0 32 32 128 81 Y-G 1Ac1an 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 �1 c '1344ocs- .0.143 iv 400 ' 255 0' 0 0 0 0 0. 0 '0 .tAclan -. -:t270 w. .. 3556 _, 55z1 -0 � 0 0 ..0. .'.0 . or. .- 0 '. 0 �G 4A5-2on . ':0.770 - w -21.56 .. 19.31 - -' 0 0 . 0- ".0. '.0 0, _ 0 - 0 P 12C-0sw 0.091 - Z55 1.28 0 0 0 0 0- 0 0 0 C-" yi 6A30ind:.. :0.032 '. '-..0.90 > .2.32 •45. 45. ' 40 104' - :209 - 204' ° 182 : .,472 F 22A-tpl 0.989 - 27.69 0.00 45 5 138 - 0 204 34 w 0 6 c)AED excursion -16 -65 Envelope loss/gain 339 190 2978 3106 12 a) In6ftratlon 87 24 593 162 b) Roomventilation 1 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliancesrolher 0 0 Subtotal (lines 6 to 13) 425 214 3671 3498 Less exiertal load 0 0 0 0 Less transfer 0 0 0 0 Redshibution 0 0 0 0 414S'6Nej 425 214 3571 3498 Duct bads 32% 49% 135 104 32% 49% 1131 1704 Total room load 560 318 4702 5203 Air required (rim) 28 1a 232 232 A -FI i- wrightsoftr RlghtSulte9 Universe] 2017 17.0.14 RSU08101 ... ulck Calcs\Documents\THE GRAND CARLTON-1446.mp Calc = MJS Front Doorfaces: 2017-Apr-11 09:29:38 Page 3 r wrightsoft' Right-M Worksheet Joe: Entire House Date: QUICK CALCS, INC. By. 317 ST., LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-06"799 Fax 772-46"796 Emil: OUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DINING ad wall 6.0 ft 47.0 ft 3 REm height 8.0 ft heat/cool 9.8 ft heat(cool 4 Room dimensions 7.0 x 6.0 It 1.0 x 526.0 It 5 Room area 42.0 ft2 526.0 ft- Ty Consbuction U-%alue Or HTM Area Load Am number (BtutVft-F) (Btuwft2) or perimeter (ft) (Btuh) or perimeter (ft) (&uh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 47/ LG. i134-0ocs... - ....:0143 Z55.;0 --, .0 .. 0 ... ..0;255 .1217 ' ' 869 5552 4A5-tam '� .0.770 n..'-21.56 `. 19.31 .. 0.. 0 0 - ` :0 "'.38`- :0 . 730 YI/ 13A-0ccs 0.143 a 4.00 Z55 0 0 0 - 0 0 0 .815 0 0 L----G D 1Aciom 1.270 a 3556 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W- :13AAos 0:143 se .4.00 255 0 0 0 0 0 0 0 - 0 1M Y-C 13A4ms 0.143 s 4.00 265 48 46 192 122 0 0 0 0 1Aclon 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-4acs 0143 w .. 4.00 Z55 0 0 0 0 206 165 661 42o , 1Rc1om::, '4A5-tan- 1.270 w„ 35.56: 5521 .0 - 0 0. 0 0 .%0 0 �. 0 ," ,: -0770 . w: i .21.56 > 19.31 0 -0 - -'0 - 0 41 41 880 `.. 785 P 12C-0sw 0.091 - 255 1.28 56 56 143 72 0 0 0 0 C - {_; 16A:30md- - ` '0.032- _ -. 0.90 '.- "2.32' -'42 42 . "�- .38 _ 97 .528 `.,: 'b26 471 -...:i220 F i 22A,tpl 0.989 - 27.69 0.00 42 6 166 0 526 47 1302 0 6 c)AED extrusion -22 668 Envelope Ims/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 643 298 5994 5112 '22'Iced 0 0 0 0 ansfer 0 0 0 0 bu0on0 00 014l643 LRd 298 5994 5112 16ads32% 49% 204 145 32-A 497 1899 24M omToad 846443 7892ired (ofm) 42 20 390 338 .Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsofY Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page Ad& e 4 ...uick Calcs\DocumentslTHE GRAND CARLTON4446.mp Cale = MJ8 Front Door faces: N 9 wrightsoft Right4@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. 1-1.161E LN., FT 'PIERCE, FL 34946 Phone; 772466-6799 Fax 772466E796 Email: QUCKCALCS@A0LCOM I Room name FOYER M. BATH 2 Famed wall 7.0 ft 8.0 If 3 height: 8.0 ft heat/cool 8.0 ft heatfcool 4 Room dimensions 1.0 x 50.0 If 7.0 x 8.0 ft 5 Room area 50.0 W 56.0 ft- Ty Construction U-value Or 14TM Area (ft5 Load Am Load number (BIWIFt;T) (Btuh(111) or perimeter (ft) (Btuh) or perimeter (11) (Btuh) Heat Cool Gross NIPIS Heat Cool Gross Wpm Heat Cool 6 LG '12Lk4ocs 0.143 ,.'n 400 2.55 6 32 20 -0 �0 , ",o 0 4AS-20rin 0.770 --o2l. 55 19.31 18 w -0, 0 S", : . . 13A4ocs 0.143 a 4.00 2.55 48 27 108 69 0 a 0, 0 1A,c1cm 1.270 a 35.66 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W - 13A4xs 0:143 se 4.00 2.55 0 0 0 0 a 0 0 0 ILG 13A4ocs 0.143 a 4.00 265 a 0 0 0 64 57 228 14 '5 1Aclom 1.270 a 35.56 34.77 a 0 0 0 7 7 247 241 13A-4ocs 0.143 w 4.OD 2.55 0 0 0 0 0 0 0 1A,cicm 1270 w 35.56 55.21 0 0 0: 0 0 O:L' -,`o 4A5-26m 0.770 W, : -21M 19.'31 0 0. 6 ..0: 0 .�O -1,0 -0 12C-1sw 0.091 - 255 1.28 72 72 183 92 a 0 0 0 C 0.032 - .0.90 'Z32 50 750 45 116 66 -50 130 F 22A-tPl 0.989 27.69 0.00 so 7 194 0 56 8 222. 0 6 c)AED excursion -39 -W Envelope IoWgaln 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Roomventflation 0 a 0 0 13 hitemal gains: Occupants @ 23D 0 0 0 0 AWiancestother 0 0 Subtotal Qlras 6 to 13) 913 529 885 516 Less to loadd 0 0 0 0 0 Less'a' 0 0 0 0 RedWrIbutIon 0 0 0 0 1:4 Subtotal 913 M M 516 15 Duct I..da 32-1. 49% 21191 MI 32%1, 49% 280 251 o t =m load Total 1 12021 7871 1 1 11661 -M I Wrad (.f,) 59 35 "a 34 .4ft -Fti- wrightsaft- Right-SufteO Unhersal 2017 17.0.14 RSU08101 ... uIck CaIcsWocunnents%THE GRAND CARLTON-1446.rup Colo = MJ8 Front Door faces: N 2017-Apr-11 09:29:38 Page 5 - wrightsoftDuct System Summary Date: EnSre House By: QUICK CALCS, INC. 317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-46"796 Emil: OUICKCALCS@AOL.COM el Intormation For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250' in H2O 0.285 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (n) Duct Matt Actual Ln (ft) Fig.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 OxO VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 SO BEDROOM -A h 3327 164 163 0.300 6.0 OxO VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 OxO VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 OxO VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 OxO VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115.0 st1 M.BAn+A In 768 58 34 0 0 OxO VIFx 0 0 ' wic c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (In) Material Trunk st2 Peak AVF 721 . 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VInIFIX yJL} wri htsoft 2017-Apr-11 09:29:38 " f 9 RlghtSuile® Uniwmal 2017 17.0.14 RSU08101 Page 1 ...Lick CalcslDocuments\THE GRAND CARLTON-1446.tup Cale = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (iri) Htg (cfm) clg (cfm) TEL (ft) Design FIR Veloc (fpm) I Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 0x0 1160 1160 0 1 0 0 0 0x 0 VIFx Wil Y` 2017-Apr-11 09:29:38 9htSOfRightSuite® Universal 201717.0.14 RSU08101 Page 2 ...uick Calcs\DocumentslTHE GRAND CARLTON-1446.tup Cale = MJ8 Front Door faces: N